Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Fa Yi Xue Za Zhi ; 39(6): 535-541, 2023 Dec 25.
Artigo em Inglês, Zh | MEDLINE | ID: mdl-38228471

RESUMO

OBJECTIVES: Fourier transform infrared spectroscopy (FTIR) was used to analyze myocardial infarction tissues at different stages of pathological change to achieve the forensic pathology diagnosis of acute and old myocardial infarction. METHODS: FTIR spectra data of early ischemic myocardium, necrotic myocardium, and myocardial fibrous tissue in the left ventricular anterior wall of the sudden death group of atherosclerotic heart disease and the myocardium of the normal control group were collected using hematoxylin-eosin (HE) and immunohistochemistry (IHC) staining as a reference, and the data were analyzed using multivariate statistical analysis. RESULTS: The mean normalized spectra of control myocardium, early ischemic myocardium and necrotic myocardium were relatively similar, but the mean second derivative spectra were significantly different. The peak intensity of secondary structure of proteins in early ischemic myocardium was significantly higher than in other types of myocardium, and the peak intensity of the α-helix in necrotic myocardium was the lowest. The peaks of amide Ⅰ and amide Ⅱ in the mean normalized spectra of myocardial fibrous tissue significantly shifted towards higher wave numbers, the peak intensities of amide Ⅱ and amide Ⅲ were higher than those of other types of myocardium, and the peak intensities at 1 338, 1 284, 1 238 and 1 204 cm-1 in the mean second derivative spectra were significantly enhanced. Principal component analysis (PCA) and partial least square-discriminant analysis (PLS-DA) showed that FTIR could distinguish different types of myocardium. CONCLUSIONS: FTIR technique has the potential to diagnose acute and old myocardial infarction, and provides a new basis for the analysis of the causes of sudden cardiac death.


Assuntos
Infarto do Miocárdio , Humanos , Amidas , Morte Súbita Cardíaca , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/patologia , Miocárdio/patologia , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Patologia Legal
2.
Fa Yi Xue Za Zhi ; 38(1): 14-19, 2022 Feb 25.
Artigo em Inglês, Zh | MEDLINE | ID: mdl-35725699

RESUMO

Diatom test is the main laboratory test method in the diagnosis of drowning in forensic medicine. It plays an important role in differentiating the antemortem drowning from the postmortem drowning and inferring drowning site. Artificial intelligence (AI) automatic diatom test is a technological innovation in forensic drowning diagnosis which is based on morphological characteristics of diatom, the application of AI algorithm to automatic identification and classification of diatom in tissues and organs. This paper discusses the morphological diatom test methods and reviews the research progress of automatic diatom recognition and classification involving AI algorithms. AI deep learning algorithm can assist diatom testing to obtain objective, accurate, and efficient qualitative and quantitative analysis results, which is expected to become a new direction of diatom testing research in the drowning of forensic medicine in the future.


Assuntos
Diatomáceas , Afogamento , Inteligência Artificial , Autopsia , Afogamento/diagnóstico , Humanos , Pulmão
3.
Fa Yi Xue Za Zhi ; 38(1): 31-39, 2022 Feb 25.
Artigo em Inglês, Zh | MEDLINE | ID: mdl-35725701

RESUMO

OBJECTIVES: To select four algorithms with relatively balanced complexity and accuracy among deep learning image classification algorithms for automatic diatom recognition, and to explore the most suitable classification algorithm for diatom recognition to provide data reference for automatic diatom testing research in forensic medicine. METHODS: The "diatom" and "background" small sample size data set (20 000 images) of digestive fluid smear of corpse lung tissue in water were built to train, validate and test four convolutional neural network (CNN) models, including VGG16, ResNet50, InceptionV3 and Inception-ResNet-V2. The receiver operating characteristic curve (ROC) of subjects and confusion matrixes were drawn, recall rate, precision rate, specificity, accuracy rate and F1 score were calculated, and the performance of each model was systematically evaluated. RESULTS: The InceptionV3 model achieved much better results than the other three models with a balanced recall rate of 89.80%, a precision rate of 92.58%. The VGG16 and Inception-ResNet-V2 had similar diatom recognition performance. Although the performance of diatom recall and precision detection could not be balanced, the recognition ability was acceptable. ResNet50 had the lowest diatom recognition performance, with a recall rate of 55.35%. In terms of feature extraction, the four models all extracted the features of diatom and background and mainly focused on diatom region as the main identification basis. CONCLUSIONS: Including the Inception-dependent model, which has stronger directivity and targeting in feature extraction of diatom. The InceptionV3 achieved the best performance on diatom identification and feature extraction compared to the other three models. The InceptionV3 is more suitable for daily forensic diatom examination.


Assuntos
Aprendizado Profundo , Diatomáceas , Algoritmos , Humanos , Redes Neurais de Computação , Curva ROC
4.
Fa Yi Xue Za Zhi ; 32(1): 13-7, 2016 Feb.
Artigo em Zh | MEDLINE | ID: mdl-27295850

RESUMO

OBJECTIVE: To establish a diagnostic model for diffuse axonal injury (DAI) by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). To screen the proteins or peptides associated with DAI for providing the biomarkers with theoretic foundation. METHODS: Fifteen male Sprague-Dawley rats were randomly divided into DAI group (n = 10) and control group (n = 5). The protein or peptide expression profiles of rat brain stem were detected by MALDI-TOF-MS. ClinProTools 2.2 software was used to find specific peaks, and a diagnostic model was established by the genetic algorithm. RESULTS: There were significant differences in 61 peaks of DAI group (P < 0.05), 9 peaks were down-regulated and 52 up-regulated. The diagnostic model was established based on 5 different peaks. The specificity and sensitivity of cross validation was 96.14% and 95.98%; while the specificity and sensitivity of blind validation showed was 73.33% and 70.00%, respectively. CONCLUSION: A specific and sensitive diagnostic model of DAI can be established by MALDI-TOF-MS to provide a potential value for determining DAI in forensic practice.


Assuntos
Tronco Encefálico/metabolismo , Lesão Axonal Difusa/diagnóstico , Peptídeos/sangue , Proteômica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Animais , Biomarcadores , Lesão Axonal Difusa/sangue , Regulação para Baixo , Masculino , Ratos , Ratos Sprague-Dawley , Sensibilidade e Especificidade , Software , Regulação para Cima
5.
Fa Yi Xue Za Zhi ; 32(2): 126-30, 2016 Apr.
Artigo em Zh | MEDLINE | ID: mdl-27501686

RESUMO

Matrix-assisted laser desorption/ionization time-of-flight imaging mass spectrometry (MALDI-TOF-IMS) has been a classical technique for studying proteomics in present and a tool for analyzing the distribution of proteins and small molecules within biological tissue sections. MALDI-TOF-IMS can analyze multiple unknown compounds in biological tissue sections simultaneously through a single measurement which can obtain molecule imaging of the tissue while maintaining the integrity of cellular and molecules in tissue. In recent years, imaging mass spectrometry technique develops relatively quickly in all biomedical domain. This paper based on the relevant data and reviews the present developing level of MALDI-TOF-IMS, the principle of imaging mass spectrometry, methology and the prospect in forensic pathology.


Assuntos
Ciências Forenses/métodos , Proteômica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Diagnóstico por Imagem , Humanos , Masculino , Proteínas
6.
Fa Yi Xue Za Zhi ; 31(4): 257-61, 2015 Aug.
Artigo em Zh | MEDLINE | ID: mdl-26665876

RESUMO

OBJECTIVE: To observe the chemical groups changing in rat kidney with regard to fatal hyperthermia by Fourier transform infrared microspectroscopy (FTIR-MSP) and to provide a new method to diagnose fatal hyperthermia. METHODS: Rats were sacrificed by hyperthermia, brainstem injury, massive hemorrhage and asphyxiation and divided into groups. The renal samples were dissected immediately after death. The data of infrared spectroscopy in glomerulus were measured by FTIR-MSP. RESULTS: The absorbances of 3290, 3070, 2850, 1540 and 1396 cm(-1) significantly increased (P < 0.05), and the ratios of Al650/A3290 and A1650/A1540 significantly decreased (P < 0.05) in group of hyperthermia. CONCLUSION: FTIR-MSP can analyze the changes of chemical groups of kidney as an auxiliary diagnosis for discriminating hyperthermia with other causes of death.


Assuntos
Febre/mortalidade , Rim/metabolismo , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Animais , Análise de Fourier , Microespectrofotometria , Ratos
7.
Fa Yi Xue Za Zhi ; 31(4): 287-92, 297, 2015 Aug.
Artigo em Zh | MEDLINE | ID: mdl-26665883

RESUMO

Postmortem chemistry is becoming more and more essential in routine forensic pathology and has made considerable progress over the past years. Biochemical analyses of vitreous humor, blood, urine and cerebrospinal fluid may provide important information in determining the cause of death or in elucidating forensic issues. Postmortem chemistry may be essential for the determination of cause of death when morphological methods (diabetes mellitus, alcoholic ketoacidosis and electrolytic disorders) cannot detect the pathophysiological changes involved in the death process. It can also provide many information in other forensic situations, including myocardial ischemia, sepsis, inflammation, infection, anaphylaxis and hormonal disturbances. The most recent relevant research advances on glucose metabolism, liver function, cardiac function, renal function, sepsis, inflammation, infection, anaphylaxis and hormonal aspect are hereby reviewed.


Assuntos
Autopsia/métodos , Líquidos Corporais/química , Patologia Legal/métodos , Mudanças Depois da Morte , Anafilaxia , Autopsia/tendências , Biomarcadores/análise , Morte , Diabetes Mellitus , Humanos , Sepse , Corpo Vítreo
8.
Fa Yi Xue Za Zhi ; 31(1): 15-9, 2015 Feb.
Artigo em Zh | MEDLINE | ID: mdl-26058127

RESUMO

OBJECTIVE: To explore the application value of multi-slice spiral computed tomography (MSCT) in traffic accidents through observing and analyzing the injury features of the accidents. METHODS: Two fatal cases caused by traffic accidents were fully examined using MSCT, 3D imaging reconstruction and angiography through cardiac puncture. The features of traffic injury mechanism were analyzed through combination of MSCT and postmortem external examination. RESULTS: In case 1, right cardiac rupture was found by MSCT and angiography through cardiac puncture. The cause of death was cardiac tamponade and right ventricular rupture due to the crush injury of chest in the traffic accident. In case 2, splenic rupture and intra-abdominal hemorrhage was found and caused by injury of left trunk by MSCT. The cause of death was hemorrhage and traumatic shock. CONCLUSION: MSCT could observe skeletal injury, soft tissue injury, and hematologic disorder well. The combination use of MSCT and angiography through cardiac puncture provided assistance to the diagnosis of cardiovascular system injury.


Assuntos
Acidentes de Trânsito/mortalidade , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Ferimentos e Lesões/mortalidade , Autopsia , Evolução Fatal , Hemorragia , Humanos , Lesões dos Tecidos Moles , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/patologia
9.
Sci Justice ; 54(1): 98-104, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24438785

RESUMO

This technical note describes a method for distinguishing normal skin tissue samples from those electrically injured by Fourier transform infrared microspectroscopy (FTIR MSP). Furthermore, the infrared spectral features of electrically injured cells and tissues were evaluated to identify molecular changes in epidermal cells. In the present study, 20 human hand tissue samples were evaluated macroscopically and histopathologically. The electrically injured skin samples were subdivided into 2 regions [normal cell regions (NCRs) and polarized cell regions (PCRs)] and 14 major spectral absorption bands were selected. The spectral results showed that the band absorbance at 1080, 1126, 1172, 1242, 1307, 1403, 1456, 1541, 2852, 2925, 2957, 3075, and 3300cm(-1) increased significantly both in the stratum and non-stratum corneum of the PCRs in electrically injured skin tissues samples. No significant difference was found between normal skin and the NCR of the electrically injured skin samples. The band absorbance ratios of A1172/A1126, A1456/A1403, and A2925/A2957 were significantly increased, whereas the A1652/A1541 ratio was decreased in the PCR of the stratum corneum and non-stratum corneum. Baseline changes from 4000 to near 1737cm(-1) were observed in the spectra of the electrically injured skin samples, which were interpreted in terms of the pathological process involved in electrical injury. FTIR-MSP presents a useful method to provide objective spectral markers for the assisted diagnosis of electrical marks.


Assuntos
Traumatismos por Eletricidade/patologia , Pele/lesões , Pele/patologia , Espectroscopia de Infravermelho com Transformada de Fourier , Adulto , Feminino , Traumatismos da Mão/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
10.
Fa Yi Xue Za Zhi ; 30(4): 241-4, 2014 Aug.
Artigo em Zh | MEDLINE | ID: mdl-25434082

RESUMO

OBJECTIVE: To explore the changes and rules of biochemical markers in serum of guinea pigs after death caused by hypothermia and to provide references for fatal hypothermia diagnosis by serum biochemical markers. METHODS: Twenty guinea pigs were randomly divided into experimental group and control group. The guinea pigs in the experimental group were kept at -30 °C until death, while the ones in control group were decapitated after same survival intervals at 25 °C. The serum was extracted from the whole blood of right ventricular immediately. Subsequently, a series of serum biochemical markers were analyzed by auto bio-chemical analyzer. RESULTS: The levels of glucose, uric acid, creatinine and urea nitrogen in the experimental group were significantly higher than those in control group, respectively (P<0.05). Compared with the control group, the levels of total protein and albumin were significantly lower in the experimental group (P<0.05). There were no significantly differences of the levels of other markers such as serum enzymes and ions observed between the two groups. CONCLUSION: There are characteristic changes of some specific serum biochemical markers in fatal hypothermia, which may be potentially useful for auxiliary diagnosis of fatal hypothermia.


Assuntos
Biomarcadores/sangue , Hipotermia , Animais , Causas de Morte , Cobaias
11.
Fa Yi Xue Za Zhi ; 30(5): 321-4, 336, 2014 Oct.
Artigo em Zh | MEDLINE | ID: mdl-25993743

RESUMO

OBJECTIVE: To establish standardized methods and parameters of the isolated heart coronary angiography through the experiment of in vitro porcine heart by MSCT. METHODS: Based on different perfusion volume (50, 60 and 70 mL) and different perfusion-imaging time (5, 10 and 20 min), the in vitro porcine coronary artery was injected liposoluble and water-soluble contrast agents using remodel angiography equipment and scanned by MSCT. And the 3D image results were compared. The images were recorded and evaluated by 2 radiologists and analyzed by statistical software. RESULTS: Liposoluble contrast agent affected the images by damaging and infiltrating the fats around the coronary artery, while the water-soluble contrast agent didn't affect the images. The groups with 60 mL or 70 mL perfusion and 5 min perfusion-imaging time had the best images. CONCLUSION: The suitable parameters of the angiography lay the foundation of postmortem coronary angiography.


Assuntos
Angiografia Coronária/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Validação de Programas de Computador , Animais , Angiografia Coronária/veterinária , Vasos Coronários/diagnóstico por imagem , Coração , Técnicas In Vitro , Tomografia Computadorizada Multidetectores/veterinária , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Software , Suínos
12.
Fa Yi Xue Za Zhi ; 30(4): 304-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25434095

RESUMO

The combination use of dexamethasone and calcium gluconate can be applied to hypersensitivity. Severe hypokalemia is a usual complication of dexamethasone and calcium gluconate therapy, which occurs frequently with therapeutic use. Fatal cases, accidental and intentional, occur frequently in forensic practice. The current case report presented a 43-year-old man with diabetes mellitus with infection, to whom dexamethasone and calcium gluconate were administered in the private clinic. With the development of such clinical symptoms of severe hypokalemia as quadriplegia, he was confirmed to have severe hypokalemia through a biochemical test before dying of arrhythmia. And also it presented pathophysiologic mechanism underlying severe hypokalemia as well as suggestions for clinical practice regarding combination use of dexamethasone and calcium gluconate.


Assuntos
Anti-Inflamatórios/efeitos adversos , Gluconato de Cálcio/efeitos adversos , Dexametasona/efeitos adversos , Hipopotassemia/induzido quimicamente , Adulto , Diabetes Mellitus , Evolução Fatal , Humanos , Masculino
13.
Fa Yi Xue Za Zhi ; 29(6): 405-8, 2013 Dec.
Artigo em Zh | MEDLINE | ID: mdl-24665608

RESUMO

OBJECTIVE: To investigate and analyze the changes of postmortem human biochemical indexes. METHODS: Subclavian venous blood samples were collected from 81 cases of traffic fatalities. Thirteen blood biochemical indexes including liver function (ALT, AST, TBIL and DBIL), renal function (UA and Cr), cardiac function (CK, CK-MB and LDH), electrolytes (K+, Na+ and Cl-), and glucose (GLU) were tested by Roche cobas c311 automatic biochemical analyzer. The descriptive analysis was made by SPSS 17.0 statistical software. RESULTS: The values of ALT, AST, CK, CK-MB, LDH and K+ were higher than normal reference values with more fluctuations. The values of TBIL, DBIL, UA, Cr, Na+, Cl- and GLU were relatively stable with less fluctuations. CONCLUSION: The postmortem human blood biochemical indexes of liver function, renal function, cardiac function, electrolytes and glucose could be affected by the factors, especially hemolysis and autolysis. The biochemical indexes, particularly enzymes, increased significantly with higher standard deviation.


Assuntos
Autopsia , Análise Química do Sangue/métodos , Acidentes de Trânsito/mortalidade , Testes de Função Cardíaca , Humanos , Testes de Função Renal , Testes de Função Hepática , Valores de Referência
14.
Fa Yi Xue Za Zhi ; 26(5): 349-52, 2010 Oct.
Artigo em Zh | MEDLINE | ID: mdl-21287738

RESUMO

OBJECTIVE: To develop a STR analysis method for analyzing DNA from stained tissue sections and to evaluate the capability of this protocol in forensic application. METHODS: Eight kinds of HE stained human tissue, for example heart, liver, lung and intestine, were collected from two autopsy cases. The genomic DNA from those tissues was extracted using a QIAgen kit. DNA quantitation was performed using the TaqMan PCR method. The concentration of DNA isolated was determined based on Ct values. Internal positive controls (IPC) were used to monitor inhibitors. DNA amplifications were performed using Identifiler PCR Amplification kit. PCR products were analyzed on 3100-Avant Genetic Analyzer. RESULTS: The concentrations of DNA obtained from all samples were greater than 1 ng/microL. PCR inhibition was not observed. However, DNA degradation, potentially due to the effect of residual formalin fixative, was observed among tissue samples stored for long periods of time. CONCLUSION: Sufficient amounts of DNA were extracted from HE stained tissue sections. STR profiles were successfully generated. The number of genotype alleles detected decreased as sample storage time increased.


Assuntos
Impressões Digitais de DNA/métodos , DNA/análise , Genética Forense/métodos , Sequências de Repetição em Tandem , Alelos , Cadáver , DNA/genética , Feminino , Genótipo , Humanos , Fígado , Pulmão , Inclusão em Parafina , Reação em Cadeia da Polimerase , Manejo de Espécimes/métodos , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA