Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Clin Microbiol ; 58(3)2020 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-31941689

RESUMO

Early diagnosis of influenza (Flu) is critical for patient management and infection control. The ID Now influenza A & B 2 (ID Now) assay (Abbott Laboratories), Cobas influenza A/B nucleic acid test (LIAT; Roche Molecular Systems, Inc.), and Xpert Xpress Flu (Xpert; Cepheid) are rapid, point-of-care molecular assays for Flu virus detection. The study aim was to compare the performances of these three commercially available Clinical Laboratory Improvement Amendments (CLIA)-waived Flu virus assays. We prospectively enrolled 201 children <18 years old from January to April 2018 and collected nasopharyngeal swab specimens in viral medium. Aliquots were frozen for testing on different diagnostic platforms, as per the manufacturers' instructions. CDC Flu A/B PCR was used as a reference method to evaluate the performances of these three platforms. Among the 201 specimens tested, the CDC Flu A/B PCR assay detected Flu A/B virus in 107 samples (Flu A virus, 73 samples; Flu B virus, 36 samples; dual Flu A/B virus positive, 2 samples), while the ID Now virus detected 102 samples (Flu A virus, 69 samples; Flu B virus, 37 samples; dual Flu A/B virus positive, 4 samples; invalid rate, 1/201 [0.5%]), the LIAT detected 112 samples (Flu A virus, 74 samples; Flu B virus, 38 samples; invalid rate, 11/201 [5.5%]), and the Xpert assay detected 112 samples (Flu A virus, 76 samples; Flu B virus, 36 samples; invalid rate, 6/201 [3.0%]). The overall sensitivities for the ID Now assay, LIAT, and Xpert assay for Flu A virus detection (93.2%, 100%, and 100%, respectively) and Flu B virus detection (97.2%, 94.4%, and 91.7%, respectively) were comparable. The specificity for Flu A and B virus detection by all methods was >97%. These molecular assays had higher sensitivity than did a historical standard-of-care test from the BD Veritor antigen test (Flu A virus, 79.5%; Flu B virus, 66.7%).


Assuntos
Influenza Humana/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Testes Imediatos , Adolescente , Criança , Pré-Escolar , Diagnóstico Precoce , Feminino , Humanos , Lactente , Recém-Nascido , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Influenza Humana/virologia , Masculino , Nasofaringe/virologia , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA