Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Artif Organs ; 44(10): 1044-1049, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32324900

RESUMO

Ventricular assist devices (VADs) are considered the standard of care for end-stage heart failure (HF) patients. Despite increasing confidence in the technology, evidence data, endorsement by scientific societies and guidelines, the number of implants reached a steady state and is not increasing at the expected pace. This is most likely related to complications that are still burdening the technology and consequently excluding the most needy, ill, and fragile population. In this manuscript we are reporting a single-center experience in a very fragile, elderly and end-stage HF population, with a superficial, partial support device: the CircuLite Synergy. The patients were included in the pre-CE mark clinical study and consequently the device underwent technical adjustment during the support, based on the complications recorded. At our institution were implanted 6 patients overall: 3 patients survived to discharge and 2 survived up to 5 years. Most of the complications recorded were due to patients' frailty and overall clinical conditions. The initial experience with the CircuLite Synergy device is proving that a more "superficial" device might be more tolerable in an elderly, frail population. Partial support has proven hemodynamically efficacious and efficient in relieving heart failure symptoms, improving medical therapy tolerability, and improving quality of life. Unfortunately, the technology was not made available due to financial uncertainty and poor management, but we hope that once the concept has been proved someone will collect the legacy.


Assuntos
Fragilidade/complicações , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fragilidade/mortalidade , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento
2.
J Clin Med ; 12(18)2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37762834

RESUMO

Infective endocarditis (IE) is still a life-threatening disease with frequent lethal outcomes despite the profound changes in its clinical, microbiological, imaging, and therapeutic profiles. Nowadays, the scenario for IE has changed since rheumatic fever has declined, but on the other hand, multiple aspects, such as elderly populations, cardiovascular device implantation procedures, and better use of multiple imaging modalities and multidisciplinary care, have increased, leading to escalations in diagnosis. Since the ESC and AHA Guidelines have been released, specific aspects of diagnostic and therapeutic management have been clarified to provide better and faster diagnosis and prognosis. Surgical treatment is required in approximately half of patients with IE in order to avoid progressive heart failure, irreversible structural damage in the case of uncontrolled infection, and the prevention of embolism. The timing of surgery has been one of the main aspects discussed, identifying cases in which surgery needs to be performed on an emergency (within 24 h) or urgent (within 7 days) basis, irrespective of the duration of antibiotic treatment, or cases where surgery can be postponed to allow a brief period of antibiotic treatment under careful clinical and echocardiographic observation. Mainly, guidelines put emphasis on the importance of an endocarditis team in the handling of systemic complications and how they affect the timing of surgery and perioperative management. Neurological complications, acute renal failure, splenic or musculoskeletal manifestations, or infections determined by multiresistant microorganisms or fungi can affect long-term prognosis and survival. Not to be outdone, anatomical and surgical factors, such as the presence of native or prosthetic valve endocarditis, a repair strategy when feasible, anatomical extension and disruption in the case of an annular abscess (mitral valve annulus, aortic mitral curtain, aortic root, and annulus), and the choice of prosthesis and conduits, can be equally crucial. It can be hard for surgeons to maneuver between correct pre-operative planning and facing unexpected obstacles during intraoperative management. The aim of this review is to provide an overview and analysis of a broad spectrum of specific surgical scenarios and how their challenging management can be essential to ensure better outcomes and prognoses.

4.
Ital J Anat Embryol ; 119(1): 20-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25345072

RESUMO

OBJECTIVE: Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. METHODS: Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. RESULTS: Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. CONCLUSIONS: bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.


Assuntos
Doenças Genéticas Ligadas ao Cromossomo X/patologia , Doenças Genéticas Ligadas ao Cromossomo X/cirurgia , Implante de Prótese de Valva Cardíaca , Prolapso da Valva Mitral/patologia , Prolapso da Valva Mitral/cirurgia , Valva Mitral/patologia , Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/patologia , Calcinose/cirurgia , Ecocardiografia Transesofagiana , Feminino , Doenças Genéticas Ligadas ao Cromossomo X/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA