Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Lancet Oncol ; 20(1): 100-109, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30470502

RESUMO

BACKGROUND: Whether multiparametric MRI improves the detection of clinically significant prostate cancer and avoids the need for systematic biopsy in biopsy-naive patients remains controversial. We aimed to investigate whether using this approach before biopsy would improve detection of clinically significant prostate cancer in biopsy-naive patients. METHODS: In this prospective, multicentre, paired diagnostic study, done at 16 centres in France, we enrolled patients aged 18-75 years with prostate-specific antigen concentrations of 20 ng/mL or less, and with stage T2c or lower prostate cancer. Eligible patients had been referred for prostate multiparametric MRI before a first set of prostate biopsies, with a planned interval of less than 3 months between MRI and biopsies. An operator masked to multiparametric MRI results did a systematic biopsy by obtaining 12 systematic cores and up to two cores targeting hypoechoic lesions. In the same patient, another operator targeted up to two lesions seen on MRI with a Likert score of 3 or higher (three cores per lesion) using targeted biopsy based on multiparametric MRI findings. Patients with negative multiparametric MRI (Likert score ≤2) had systematic biopsy only. The primary outcome was the detection of clinically significant prostate cancer of International Society of Urological Pathology grade group 2 or higher (csPCa-A), analysed in all patients who received both systematic and targeted biopsies and whose results from both were available for pathological central review, including patients who had protocol deviations. This study is registered with ClinicalTrials.gov, number NCT02485379, and is closed to new participants. FINDINGS: Between July 15, 2015, and Aug 11, 2016, we enrolled 275 patients. 24 (9%) were excluded from the analysis. 53 (21%) of 251 analysed patients had negative (Likert ≤2) multiparametric MRI. csPCa-A was detected in 94 (37%) of 251 patients. 13 (14%) of these 94 patients were diagnosed by systematic biopsy only, 19 (20%) by targeted biopsy only, and 62 (66%) by both techniques. Detection of csPCa-A by systematic biopsy (29·9%, 95% CI 24·3-36·0) and targeted biopsy (32·3%, 26·5-38·4) did not differ significantly (p=0·38). csPCa-A would have been missed in 5·2% (95% CI 2·8-8·7) of patients had systematic biopsy not been done, and in 7·6% (4·6-11·6) of patients had targeted biopsy not been done. Four grade 3 post-biopsy adverse events were reported (3 cases of prostatitis, and 1 case of urinary retention with haematuria). INTERPRETATION: There was no difference between systematic biopsy and targeted biopsy in the detection of ISUP grade group 2 or higher prostate cancer; however, this detection was improved by combining both techniques and both techniques showed substantial added value. Thus, obtaining a multiparametric MRI before biopsy in biopsy-naive patients can improve the detection of clinically significant prostate cancer but does not seem to avoid the need for systematic biopsy. FUNDING: French National Cancer Institute.


Assuntos
Biópsia Guiada por Imagem/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Adolescente , Adulto , Idoso , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Masculino , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética Multiparamétrica , Estudos Prospectivos , Próstata/diagnóstico por imagem , Próstata/patologia , Antígeno Prostático Específico/sangue , Ultrassonografia de Intervenção , Adulto Jovem
2.
Int J Urol ; 25(12): 990-997, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30187529

RESUMO

OBJECTIVES: To assess the accuracy of Koelis fusion biopsy for the detection of prostate cancer and clinically significant prostate cancer in the everyday practice. METHODS: We retrospectively enrolled 2115 patients from 15 institutions in four European countries undergoing transrectal Koelis fusion biopsy from 2010 to 2017. A variable number of target (usually 2-4) and random cores (usually 10-14) were carried out, depending on the clinical case and institution habits. The overall and clinically significant prostate cancer detection rates were assessed, evaluating the diagnostic role of additional random biopsies. The cancer detection rate was correlated to multiparametric magnetic resonance imaging features and clinical variables. RESULTS: The mean number of targeted and random cores taken were 3.9 (standard deviation 2.1) and 10.5 (standard deviation 5.0), respectively. The cancer detection rate of Koelis biopsies was 58% for all cancers and 43% for clinically significant prostate cancer. The performance of additional, random cores improved the cancer detection rate of 13% for all cancers (P < 0.001) and 9% for clinically significant prostate cancer (P < 0.001). Prostate cancer was detected in 31%, 66% and 89% of patients with lesions scored as Prostate Imaging Reporting and Data System 3, 4 and 5, respectively. Clinical stage and Prostate Imaging Reporting and Data System score were predictors of prostate cancer detection in multivariate analyses. Prostate-specific antigen was associated with prostate cancer detection only for clinically significant prostate cancer. CONCLUSIONS: Koelis fusion biopsy offers a good cancer detection rate, which is increased in patients with a high Prostate Imaging Reporting and Data System score and clinical stage. The performance of additional, random cores seems unavoidable for correct sampling. In our experience, the Prostate Imaging Reporting and Data System score and clinical stage are predictors of prostate cancer and clinically significant prostate cancer detection; prostate-specific antigen is associated only with clinically significant prostate cancer detection, and a higher number of biopsy cores are not associated with a higher cancer detection rate.


Assuntos
Imagem por Ressonância Magnética Intervencionista/métodos , Imagem Multimodal/métodos , Neoplasias da Próstata/diagnóstico , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia com Agulha de Grande Calibre/métodos , Europa (Continente) , Estudos de Viabilidade , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Próstata/diagnóstico por imagem , Próstata/patologia , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/sangue , Neoplasias da Próstata/patologia , Reprodutibilidade dos Testes , Estudos Retrospectivos
3.
Diagn Interv Imaging ; 104(10): 465-476, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37345961

RESUMO

PURPOSE: The purpose of this study was to develop and test across various scanners a zone-specific region-of-interest (ROI)-based computer-aided diagnosis system (CAD) aimed at characterizing, on MRI, International Society of Urological Pathology (ISUP) grade≥2 prostate cancers. MATERIALS AND METHODS: ROI-based quantitative models were selected in multi-vendor training (265 pre-prostatectomy MRIs) and pre-test (112 pre-biopsy MRIs) datasets. The best peripheral and transition zone models were combined and retrospectively assessed in internal (158 pre-biopsy MRIs) and external (104 pre-biopsy MRIs) test datasets. Two radiologists (R1/R2) retrospectively delineated the lesions targeted at biopsy in test datasets. The CAD area under the receiver operating characteristic curve (AUC) for characterizing ISUP≥2 cancers was compared to that of the Prostate Imaging-Reporting and Data System version2 (PI-RADSv2) score prospectively assigned to targeted lesions. RESULTS: The best models used the 25th apparent diffusion coefficient (ADC) percentile in transition zone and the 2nd ADC percentile and normalized wash-in rate in peripheral zone. The PI-RADSv2 AUCs were 82% (95% confidence interval [CI]: 74-87) and 86% (95% CI: 81-91) in the internal and external test datasets respectively. They were not different from the CAD AUCs obtained with R1 and R2 delineations, in the internal (82% [95% CI: 76-89], P = 0.95 and 85% [95% CI: 78-91], P = 0.55) and external (82% [95% CI: 74-91], P = 0.41 and 86% [95% CI:78-95], P = 0.98) test datasets. The CAD yielded sensitivities of 86-89% and 90-91%, and specificities of 64-65% and 69-75% in the internal and external test datasets respectively. CONCLUSION: The CAD performance for characterizing ISUP grade≥2 prostate cancers on MRI is not different from that of PI-RADSv2 score across two test datasets.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética , Computadores
4.
BMJ Open ; 12(2): e051274, 2022 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-35140147

RESUMO

INTRODUCTION: Prostate multiparametric MRI (mpMRI) has shown good sensitivity in detecting cancers with an International Society of Urological Pathology (ISUP) grade of ≥2. However, it lacks specificity, and its inter-reader reproducibility remains moderate. Biomarkers, such as the Prostate Health Index (PHI), may help select patients for prostate biopsy. Computer-aided diagnosis/detection (CAD) systems may also improve mpMRI interpretation. Different prototypes of CAD systems are currently developed under the Recherche Hospitalo-Universitaire en Santé / Personalized Focused Ultrasound Surgery of Localized Prostate Cancer (RHU PERFUSE) research programme, tackling challenging issues such as robustness across imaging protocols and magnetic resonance (MR) vendors, and ability to characterise cancer aggressiveness. The study primary objective is to evaluate the non-inferiority of the area under the receiver operating characteristic curve of the final CAD system as compared with the Prostate Imaging-Reporting and Data System V.2.1 (PI-RADS V.2.1) in predicting the presence of ISUP ≥2 prostate cancer in patients undergoing prostate biopsy. METHODS: This prospective, multicentre, non-inferiority trial will include 420 men with suspected prostate cancer, a prostate-specific antigen level of ≤30 ng/mL and a clinical stage ≤T2 c. Included men will undergo prostate mpMRI that will be interpreted using the PI-RADS V.2.1 score. Then, they will undergo systematic and targeted biopsy. PHI will be assessed before biopsy. At the end of patient inclusion, MR images will be assessed by the final version of the CAD system developed under the RHU PERFUSE programme. Key secondary outcomes include the prediction of ISUP grade ≥2 prostate cancer during a 3-year follow-up, and the number of biopsy procedures saved and ISUP grade ≥2 cancers missed by several diagnostic pathways combining PHI and MRI findings. ETHICS AND DISSEMINATION: Ethical approval was obtained from the Comité de Protection des Personnes Nord Ouest III (ID-RCB: 2020-A02785-34). After publication of the results, access to MR images will be possible for testing other CAD systems. TRIAL REGISTRATION NUMBER: NCT04732156.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Inteligência Artificial , Humanos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Estudos Prospectivos , Neoplasias da Próstata/diagnóstico , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA