Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 97(3): 431-436, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32077590

RESUMO

BACKGROUND: Quantitative flow ratio (QFR) has been validated as an accurate surrogate of standard wire-based fractional flow reserve. The clinical and angiographic outcomes of the Fantom sirolimus-eluting bioresorbable coronary scaffold (BRS) have been previously studied and reported. We investigate the functional performance of the Fantom BRS. METHODS: The FANTOM II trial prospectively enrolled 240 patients with stable coronary artery disease or unstable angina, of which 235 patients received the Fantom BRS and were included in the present analysis. We performed an independent serial QFR analysis of the target vessel at baseline, post-percutaneous coronary intervention (PCI), and at 6- or 9-month and 24-month follow-up, using a QFR threshold ≤0.80 to define functional ischemia. RESULTS: QFR was analyzable in 178 patients at baseline, 185 post-PCI, 178 at 6- or 9-month follow-up, and 30 at 24-month follow-up. At baseline, 119 patients (66.9%) had a QFR ≤0.80, whereas 12 (6.5%) post-PCI, 13 (7.3%) at 6- or 9-month follow-up, and 3 (10.0%) at 24-month follow-up had a QFR ≤0.80. QFR improved from baseline to post-PCI, and decreased from post-PCI up to 24-month follow-up. During follow-up period, 28 patients (11.9%) had target vessel revascularization, of which 21 had analyzable QFR and 16 patients (76.1%) had QFR ≤0.80 at the time of revascularization. CONCLUSIONS: Off-line serial QFR assessment demonstrated that around 30% patients did not have functionally significant lesions at baseline and the time with target vessel revascularization. PCI with the Fantom BRS improved functional ischemia with a slight decrease in QFR values over 24 months.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Implantes Absorvíveis , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Sirolimo , Resultado do Tratamento
2.
EuroIntervention ; 19(1): 37-52, 2023 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-36811935

RESUMO

Significant coronary artery disease (CAD) is a frequent finding in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI), and the management of these two conditions becomes of particular importance with the extension of the procedure to younger and lower-risk patients. Yet, the preprocedural diagnostic evaluation and the indications for treatment of significant CAD in TAVI candidates remain a matter of debate. In this clinical consensus statement, a group of experts from the European Association of Percutaneous Cardiovascular Interventions (EAPCI) in collaboration with the European Society of Cardiology (ESC) Working Group on Cardiovascular Surgery aims to review the available evidence on the topic and proposes a rationale for the diagnostic evaluation and indications for percutaneous revascularisation of CAD in patients with severe aortic stenosis undergoing transcatheter treatment. Moreover, it also focuses on commissural alignment of transcatheter heart valves and coronary re-access after TAVI and redo-TAVI.


Assuntos
Estenose da Valva Aórtica , Cardiologia , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
3.
EuroIntervention ; 18(16): e1307-e1327, 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37025086

RESUMO

Coronary computed tomographic angiography (CCTA) is becoming the first-line investigation for establishing the presence of coronary artery disease and, with fractional flow reserve (FFRCT), its haemodynamic significance. In patients without significant epicardial obstruction, its role is either to rule out atherosclerosis or to detect subclinical plaque that should be monitored for plaque progression/regression following prevention therapy and provide risk classification. Ischaemic non-obstructive coronary arteries are also expected to be assessed by non-invasive imaging, including CCTA. In patients with significant epicardial obstruction, CCTA can assist in planning revascularisation by determining the disease complexity, vessel size, lesion length and tissue composition of the atherosclerotic plaque, as well as the best fluoroscopic viewing angle; it may also help in selecting adjunctive percutaneous devices (e.g., rotational atherectomy) and in determining the best landing zone for stents or bypass grafts.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico , Angiografia Coronária/métodos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada/métodos , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Vasos Coronários/patologia
4.
Circulation ; 123(24): 2829-37, 7 p following 2837, 2011 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-21632496

RESUMO

BACKGROUND: The relationship between white blood cell count (WBCc) and mortality in patients with ST-segment-elevation acute myocardial infarction treated with percutaneous coronary intervention is poorly understood. Furthermore, whether there is a relationship between WBCc and risk of noncardiac mortality and bleeding after percutaneous coronary intervention is unknown. METHODS AND RESULTS: The baseline WBCc was available in 3193 of 3345 patients (95.5%) who underwent percutaneous coronary intervention in the Harmonizing Outcome With Revascularization and Stent in Acute Myocardial Infarction (HORIZONS-AMI) trial. In a propensity-adjusted multivariable analysis, WBCc was an independent predictor of 1-year cardiac mortality (hazard ratio, 1.15; 95% confidence interval, 1.09 to 1.22), noncardiac mortality (hazard ratio, 1.19; 95% confidence interval, 1.10 to 1.29), and major bleeding (hazard ratio, 1.08; 95% confidence interval, 1.04 to 1.12). After adjustment for baseline creatinine phosphokinase levels and left ventricular ejection fraction, WBCc remained an independent predictor of 1-year all-cause mortality and cardiac mortality. In patients matched for baseline creatinine phosphokinase levels at hospital admission, the median peak creatinine phosphokinase level was significantly higher in patients with high WBCc (>11 000 per 1 mm(3)) compared with low WBCc (1851 U/L [range, 880-3307 U/L] versus 1241 U/L [range, 540 to 2,78], respectively; P<0.0001). In this subgroup of patients, WBCc was an independent correlate of peak creatinine phosphokinase level, and remained an independent predictor of 1-year mortality. CONCLUSIONS: In patients with ST-segment-elevation acute myocardial infarction undergoing percutaneous coronary intervention, elevated baseline WBCc is an independent predictor of infarct size, as assessed by peak creatinine phosphokinase level, and of 1-year cardiac mortality, noncardiac mortality, and major bleeding.


Assuntos
Angioplastia Coronária com Balão/mortalidade , Hemorragia/mortalidade , Contagem de Leucócitos/estatística & dados numéricos , Infarto do Miocárdio , Stents/estatística & dados numéricos , Idoso , Creatina Quinase/sangue , Feminino , Hemorragia/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/imunologia , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/terapia , Valor Preditivo dos Testes , Fatores de Risco
5.
Coron Artery Dis ; 31(7): 573-577, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32868660

RESUMO

BACKGROUND: The aim of this study was to evaluate the safety and efficacy of the novel NovaCross microcatheter system in patients with ischemic heart disease due to coronary chronic total occlusions (CTO). METHODS: A total of 191 subjects between the ages of 25-80 years were recruited in 10 investigational sites. Each subject underwent a percutaneous coronary intervention (PCI) of a CTO lesion using the NovaCross microcatheter, equipped with expandable nitinol scaffolds to enhance guidewire penetration and crossing of the CTO lesion. The primary safety endpoint was procedural major adverse cardiac events [composite of death, myocardial infarction (MI), or urgent target vessel revascularization]. The primary efficacy endpoint was to assess the ability of the NovaCross microcatheter to successfully facilitate the placement of a guidewire beyond a native coronary CTO in the true vessel lumen. After the PCI, subjects remained in hospital until a 12-lead ECG and blood tests for cardiac biomarkers were taken at 3-6 h and 8-16 h post-procedure. RESULTS: No deaths, urgent revascularization, or urgent coronary artery bypass surgery were reported. The reported MI rate according to the protocol definition was 12.3%, and technical success was achieved in 75.3% of the subjects regardless of CTO procedure technique. In 89.2% of the subjects, the NovaCross succeeded in penetrating the proximal CTO cap, and in 25.8% of the subjects, the extendable portion of the NovaCross crossed the full length of the CTO lesion. CONCLUSIONS: The NovaCross met both the primary safety endpoint and the primary efficacy endpoint. We, therefore, conclude that the device is well tolerated, effective, and could be easily adopted by interventional cardiologists.


Assuntos
Ligas/farmacologia , Cateteres Cardíacos , Oclusão Coronária/cirurgia , Vasos Coronários , Intervenção Coronária Percutânea , Materiais Biocompatíveis/farmacologia , Cateteres Cardíacos/efeitos adversos , Cateteres Cardíacos/normas , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Desenho de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/prevenção & controle , Avaliação de Resultados em Cuidados de Saúde , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Stents , Alicerces Teciduais
6.
Circ Cardiovasc Interv ; 12(6): e007283, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31177821

RESUMO

Background A novel bioresorbable scaffold, the sirolimus-eluting Fantom, incorporates a radiopaque polymer, struts with a thickness of 125 µm, and a crossing profile of 1.35 mm. The purpose of this study was to evaluate the 9-month angiographic and 12-month clinical outcomes of the FANTOM scaffold in a larger patient population. Methods and Results The FANTOM II study (Safety & Performance Study of the Fantom Sirolimus-Eluting Bioresorbable Coronary Scaffold - First Report on Initial 24 Month Outcomes) was a prospective, multicenter trial which enrolled 240 patients with single de novo coronary stenosis with reference vessel diameter 2.5 to 3.5 mm diameter and lesion length ≤20 mm. Major adverse cardiac events through 12-month follow-up were assessed. Angiographic follow-up was performed in consecutive patient cohorts at 6 months (n=117) and 9 months (n=123). Acute delivery success, acute technical success, acute procedural success, and clinical procedural success rates as defined in the clinical protocol were 97.9% (235/240), 95.8% (230/240), 99.1% (228/230), and 99.6% (227/228), respectively. The mean in-stent late lumen loss at 6 months and 9 months were 0.25±0.40 mm and 0.33±0.36 mm, respectively, and in-segment binary restenosis occurred in 2.0% and 7.6% of patients, respectively. Major adverse cardiac events and target lesion failure through 12 months occurred in 4.2% of 240 patients; scaffold thrombosis developed in only one patient (0.4%). Conclusions The Fantom sirolimus-eluting bioresorbable coronary scaffold demonstrated favorable safety and effectiveness performance at 12-month follow-up. Longer-term follow-up is ongoing to examine the late outcomes with this novel device. Clinical Trial Registration URL: https://www.clinicaltrials.gov . Unique identifier: NCT02539966.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Estenose Coronária/terapia , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fármacos Cardiovasculares/efeitos adversos , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 71(2): 175-83, 2008 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-17985377

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) of coronary bifurcation lesions remains a subject of debate. Many studies have been published in this setting. They are often small scale and display methodological flaws and other shortcomings such as inaccurate designation of lesions, heterogeneity, and inadequate description of techniques implemented. METHODS: The aim is to propose a consensus established by the European Bifurcation Club (EBC), on the definition and classification of bifurcation lesions and treatments implemented with the purpose of allowing comparisons between techniques in various anatomical and clinical settings. RESULTS: A bifurcation lesion is a coronary artery narrowing occurring adjacent to, and/or involving, the origin of a significant side branch. The simple lesion classification proposed by Medina has been adopted. To analyze the outcomes of different techniques by intention to treat, it is necessary to clearly define which vessel is the distal main branch and which is (are) the side branche(s) and give each branch a distinct name. Each segment of the bifurcation has been named following the same pattern as the Medina classification. The classification of the techniques (MADS: Main, Across, Distal, Side) is based on the manner in which the first stent has been implanted. A visual presentation of PCI techniques and devices used should allow the development of a software describing quickly and accurately the procedure performed. CONCLUSION: The EBC proposes a new classification of bifurcation lesions and their treatments to permit accurate comparisons of well described techniques in homogeneous lesion groups.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/classificação , Estenose Coronária/terapia , Implantação de Prótese/métodos , Stents , Terminologia como Assunto , Angiografia Coronária/normas , Estenose Coronária/diagnóstico por imagem , Humanos
10.
Am Heart J ; 153(2): 212.e1-7, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17239678

RESUMO

BACKGROUND: Previous data suggest that bone marrow-derived stem cells (BM-SCs) decrease the infarct size and beneficially affect the postinfarction remodeling. METHODS: The Myocardial Stem Cell Administration After Acute Myocardial Infarction Study is a multicenter, prospective, randomized, single-blind clinical trial designed to compare the early and late intracoronary or combined (percutaneous intramyocardial and intracoronary) administration of BM-SCs to patients after acute myocardial infarction (AMI) with reopened infarct-related artery. The primary end points are the changes in resting myocardial perfusion defect size and left ventricular ejection fraction (gated single photon emission computed tomography [SPECT] scintigraphy) 3 months after BM-SCs therapy. The secondary end points relate to evaluation of (1) the safety and feasibility of the application modes, (2) the changes in left ventricular wall motion score index (transthoracic echocardiography), (3) myocardial voltage and segmental wall motion (NOGA mapping), (4) left ventricular end-diastolic and end-systolic volumes (contrast ventriculography), and (5) the clinical symptoms (Canadian Cardiovascular Society [CCS] anina score and New York Heart Association [NYHA] functional class) at follow-up. Three hundred sixty patients are randomly assigned into 1 of 4 groups: group A, early treatment (21-42 days after AMI) with intracoronary injection; group B, early treatment with combined application; group C, late treatment (3 months after AMI) with intracoronary delivery; and group D, late treatment with combined administration of BM-SCs. Besides the BM-SCs therapy, the standardized treatment of AMI is applied in all patients. CONCLUSIONS: The Myocardial Stem Cell Administration After Acute Myocardial Infarction Trial is the first randomized trial to investigate the effects of the combined (intramyocardial and intracoronary) and the intracoronary mode of delivery of BM-SCs therapy in the early and late periods after AMI.


Assuntos
Transplante de Medula Óssea/métodos , Infarto do Miocárdio/cirurgia , Vasos Coronários , Humanos , Estudos Multicêntricos como Assunto , Miocárdio , Estudos Prospectivos , Projetos de Pesquisa , Método Simples-Cego , Fatores de Tempo
11.
JACC Cardiovasc Interv ; 10(18): 1832-1838, 2017 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-28935075

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the outcomes of the novel Fantom coronary bioresorbable scaffold at 6 months. BACKGROUND: The Fantom sirolimus-eluting bioresorbable scaffold incorporates a unique proprietary iodinated, polycarbonate copolymer of tyrosine analogs that is radiopaque, with thin struts (125 µm) that facilitate device delivery and precise target lesion treatment. METHODS: The 6-month outcomes and performance of the Fantom scaffold were evaluated in 117 patients with single de novo native coronary artery lesions of length ≤20 mm and reference vessel diameter 2.5 to 3.5 mm. The primary angiographic endpoint was mean late lumen loss at 6 months measured by quantitative coronary angiography. Procedural outcomes were categorized as short-term technical success, short-term procedural success, and clinical procedural success. The primary clinical endpoint was major adverse cardiac events at 6 months, the composite of cardiac death, myocardial infarction (MI), or clinically driven target lesion revascularization (TLR). RESULTS: Short-term technical success, short-term procedural success, and clinical procedural success were achieved in 96.6%, 99.1%, and 99.1% of patients, respectively. Mean 6-month in-stent late lumen loss was 0.25 ± 0.40 mm (n = 100). Binary restenosis was present in 2 patients (2.0%). Major adverse cardiac events within 6 months occurred in 3 patients (2.6%), including no deaths, 2 MIs, and 2 TLRs (1 patient had both an MI and TLR). Scaffold thrombosis occurred in 1 patient (0.9%). CONCLUSIONS: The clinical results from 117 patients enrolled in cohort A of the multicenter FANTOM II (Safety & Performance Study of the FANTOM Sirolimus-Eluting Bioresorbable Coronary Scaffold) study demonstrate favorable 6-month outcomes of this novel device in the treatment of noncomplex coronary artery disease.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Sirolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Valor Preditivo dos Testes , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
12.
Am J Cardiol ; 110(7): 940-7, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22748356

RESUMO

There are limited safety and effectiveness data comparing glycoprotein IIb/IIIa inhibitors in the setting of primary percutaneous coronary intervention. In this substudy of the Harmonizing Outcomes With Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial, the clinical and bleeding outcomes of eptifibatide versus abciximab were evaluated in patients with ST-segment elevation myocardial infarction who underwent percutaneous coronary intervention. Three-year clinical outcomes of patients in the heparin plus glycoprotein IIb/IIIa inhibitor arm were compared according to treatment with abciximab (n = 907) versus eptifibatide (n = 803). Adjudicated end points included major adverse cardiovascular events (MACEs; mortality, reinfarction, ischemia-driven target vessel revascularization, or stroke), major bleeding, and net adverse clinical events (MACEs or major bleeding). Propensity score matching was used to identify 1,342 matched cases (671 each in the abciximab and eptifibatide groups). Multivariate analysis was performed in the entire cohort and the propensity-matched groups. At 3-year follow-up, eptifibatide and abciximab resulted in nonsignificantly different rates of MACEs (18.3% vs 19.6%, hazard ratio [HR] 0.93, 95% confidence interval [CI] 0.74 to 1.16, p = 0.51), major bleeding (10.7% vs 11.9%, HR 0.90, 95% CI 0.67 to 1.19, p = 0.44), and net adverse clinical events (24.5% vs 25.5%, HR 0.96, 95% CI 0.79 to 1.17, p = 0.69). Similarly, at 3 years by multivariate analysis, there was no statistically significant difference between abciximab and eptifibatide for net adverse clinical events (HR 0.89, 95% CI 0.73 to 1.09, p = 0.27), MACEs (HR 0.96, 95% CI 0.77 to 1.20, p = 0.73), and major bleeding (HR 1.05, 95% CI 0.78 to 1.41, p = 0.75). The propensity-matched groups also had similar outcomes. In conclusion, abciximab and eptifibatide have comparable bleeding risks and clinical efficacy in primary percutaneous coronary intervention.


Assuntos
Angioplastia Coronária com Balão/métodos , Anticorpos Monoclonais/administração & dosagem , Eletrocardiografia , Fragmentos Fab das Imunoglobulinas/administração & dosagem , Infarto do Miocárdio/tratamento farmacológico , Peptídeos/administração & dosagem , Abciximab , Idoso , Relação Dose-Resposta a Droga , Eptifibatida , Feminino , Seguimentos , Humanos , Incidência , Infusões Intravenosas , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Inibidores da Agregação Plaquetária/administração & dosagem , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
13.
J Am Coll Cardiol ; 59(12): 1058-72, 2012 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-22421299

RESUMO

OBJECTIVES: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. BACKGROUND: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ~10 µm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. METHODS: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. RESULTS: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. CONCLUSIONS: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/patologia , Prontuários Médicos/normas , Tomografia de Coerência Óptica/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Trombose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Medicina Baseada em Evidências , Humanos , Cooperação Internacional , Placa Aterosclerótica/diagnóstico , Padrões de Referência , Reprodutibilidade dos Testes , Túnica Íntima/patologia , Ultrassonografia
14.
JACC Cardiovasc Interv ; 3(8): 796-802, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20723849

RESUMO

OBJECTIVES: This study sought to assess the relationship between 1-year mortality and baseline patient risk in the HORIZONS-AMI (Harmonizing Outcomes with RevasculariZatiON and Stents in Acute Myocardial Infarction) trial. BACKGROUND: The HORIZONS-AMI trial showed that bivalirudin compared with unfractionated heparin (UFH) plus glycoprotein IIb/IIIa inhibitors (GPI) decreased major bleeding and 30-day and 1-year mortality in patients undergoing primary percutaneous intervention for acute myocardial infarction. METHODS: Patients in the HORIZONS-AMI trial were classified as low, intermediate, and high risk according to the CADILLAC (Controlled Abciximab and Device Investigation to Lower Late Angioplasty Complications) risk score based on 7 clinical variables. RESULTS: Among 2,530 CADILLAC-score evaluable HORIZONS-AMI trial patients, 1,522 (60%) were classified as low risk, 531 (21%) as intermediate risk, and 477 (19%) as high risk. The mortality rates in the bivalirudin and UFH plus GPI arms, respectively, were 0.4% and 1.2% (p = 0.09) in the low-risk group, 4.2% and 4.1% (p = 0.99) in the intermediate-risk group, and 8.4% and 15.9% (p = 0.01) in the high-risk group. Among high-risk patients, there was also a decreased rate of recurrent myocardial infarction in patients randomized to bivalirudin as compared to UFH plus GPI (3.6% vs. 7.9%, p = 0.04). CONCLUSIONS: In high-risk patients undergoing primary percutaneous coronary intervention for acute myocardial infarction, bivalirudin compared with UFH plus GPI reduces 1-year mortality and recurrent myocardial infarction. (HORIZONS-AMI trial; NCT00433966).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Antitrombinas/uso terapêutico , Fibrinolíticos/uso terapêutico , Infarto do Miocárdio/terapia , Fragmentos de Peptídeos/uso terapêutico , Stents , Abciximab , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Anticorpos Monoclonais/uso terapêutico , Antitrombinas/efeitos adversos , Distribuição de Qui-Quadrado , Eptifibatida , Europa (Continente) , Feminino , Fibrinolíticos/efeitos adversos , Hemorragia/induzido quimicamente , Heparina/uso terapêutico , Hirudinas/efeitos adversos , Humanos , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/mortalidade , Seleção de Pacientes , Fragmentos de Peptídeos/efeitos adversos , Peptídeos/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Medição de Risco , Fatores de Risco , Prevenção Secundária , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
JACC Cardiovasc Interv ; 3(4): 449-56, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20398874

RESUMO

OBJECTIVES: The aim of this study was to investigate the feasibility of using quantitative differential echogenicity to monitor the in vivo absorption process of a drug-eluting poly-l-lactic-acid (PLLA) bioabsorbable stent (BVS, Abbott Vascular, Santa Clara, California). BACKGROUND: A new bioabsorbable, balloon-expanded coronary stent was recently evaluated in a first-in-man study. Little is known about the absorption process in vivo in diseased human coronary arteries. METHODS: In the ABSORB (Clinical Evaluation of the BVS everolimus eluting stent system) study, 30 patients underwent treatment with the BVS coronary stent system and were examined with intracoronary ultrasound (ICUS) after implantation, at 6 months and at 2-year follow-up. Quantitative ICUS was used to measure dimensional changes, and automated ICUS-based tissue composition software (differential echogenicity) was used to quantify plaque compositional changes over time in the treated regions. RESULTS: The BVS struts appeared as bright hyperechogenic structures and showed a continuous decrease of their echogenicity over time, most likely due to the polymer degradation process. In 12 patients in whom pre-implantation ICUS was available, at 2 years the percentage-hyperechogenic tissue was close to pre-implantation values, indicating that the absorption process was either completed or the remaining material was no longer differentially echogenic from surrounding tissues. CONCLUSIONS: Quantitative differential echogenicity is a useful plaque compositional measurement tool. Furthermore, it seems to be valuable for monitoring the absorption process of bioabsorbable coronary stents made of semi-crystalline polymers.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Ácido Láctico/química , Polímeros/química , Sirolimo/análogos & derivados , Ultrassonografia de Intervenção , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Everolimo , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador , Nova Zelândia , Poliésteres , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Solubilidade , Fatores de Tempo , Resultado do Tratamento
16.
Coron Artery Dis ; 20(5): 309-16, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19543087

RESUMO

AIMS: We hypothesized that the plaque composition and plaque type classification differs between acute coronary syndrome (ACS) and stable angina (SA) patients. METHODS AND RESULTS: We analyzed culprit lesion (CL) and nonculprit lesion (NCL) of ACS patients compared with target lesion (TL) and nontarget lesion (NTL) of SA patients by intravascular ultrasound radio frequency analysis in 874 lesion segments of 424 patients (ACS: 193 patients/SA: 231 patients). Comparing all lesion segments in ACS and SA patients did not show significant differences in absolute or relative plaque composition. However, necrotic core area was larger in CL versus TL (0.9+/-0.7 vs. 0.7+/-0.5 mm, P=0.005) and all plaque components were significantly higher in CL compared with NCL and TL compared with NTL, respectively. A higher amount of thin cap fibroatheroma lesions (15.2 vs. 5.1%, P<0.0001) was detected in ACS compared with SA patients. Fibrocalcific lesions were lower in ACS patients (3 vs. 10.5%, P<0.0001). CONCLUSION: The differentiation in CL/NCL of ACS and TL/NTL of SA patients revealed significant differences in plaque composition and plaque types when examined by intravascular ultrasound radiofrequency analysis. However, considerable overlap between plaque characteristics exists for ACS and SA patients.


Assuntos
Síndrome Coronariana Aguda/diagnóstico por imagem , Angina Pectoris/diagnóstico por imagem , Angina Instável/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Ultrassonografia de Intervenção , Síndrome Coronariana Aguda/etiologia , Idoso , Angina Pectoris/etiologia , Angina Instável/etiologia , Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Estudos Transversais , Europa (Continente) , Feminino , Fibrose , Humanos , Masculino , Pessoa de Meia-Idade , Necrose , Valor Preditivo dos Testes , Sistema de Registros , Análise de Regressão , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA