Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 24(1): 849, 2023 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-37891529

RESUMO

BACKGROUND: Our study aimed to identify the relationship between treatment outcome assessed by patient-reported outcomes (PROMs) and satisfaction measured by calculation of the Net Promoter Score (NPS), which identifies promoters, following total hip arthroplasty (THA). The aim was to evaluate this association separately in primary and revision THA and to determine thresholds based on PROMs that identify detractors of the surgical procedure or the centre. METHODS: A total of 1,243 patients who underwent primary or revision THA at our hospital were asked to complete questionnaires of the Oxford Hip Score (OHS), Euroquol-5D (EQ-5D) and information on pain intensity preoperatively, three and 12 months after surgery. Postoperatively, the patients were additionally asked about their satisfaction with the procedure and the hospital by using three different NPS questions. The association between PROMs and NPS was evaluated based on group comparisons of primary or revision THA and receiver operating characteristics analysis (ROC) to determine threshold values. RESULTS: At 12 months the NPS of all three questions were invariably linked to treatment outcome in patients after primary THA and patients with a single revision. In these two treatment groups, promoters always showed significantly better PROM scores than detractors. The NPS score was always higher in the primary group in comparison to the single revision group, e.g. 66.4% would undergo the procedure again in the first group, while only 33.0% would opt for this in the latter group. The high thresholds for the PROMs at 12 months, that were calculated by ROC analysis to identify promoter/detractors, indicate that patients` satisfaction required very good joint function and pain relief. However, the NPS was not a suitable tool to identify patients who need further care in an early phase after surgery. CONCLUSIONS: With NPS already a single question or a single parameter provides the desired information regarding patient satisfaction and also treatment success. TRIAL REGISTRATION: The study was approved by the Ethics Committee at the Medical Faculty of the University Rostock: "Ethikkommission an der Medizinischen Fakultät der Universität Rostock", Address: St.-Georg Str. 108 18055 Rostock, Germany, reference number: A2015-0055.


Assuntos
Artroplastia de Quadril , Humanos , Artroplastia de Quadril/métodos , Estudos Prospectivos , Resultado do Tratamento , Satisfação do Paciente , Inquéritos e Questionários , Medidas de Resultados Relatados pelo Paciente
2.
Orthopade ; 50(5): 395-401, 2021 May.
Artigo em Alemão | MEDLINE | ID: mdl-33834286

RESUMO

The absolute number of total knee arthroplasties (TKA) continues to rise every year. About 10% of the patients are less than 55 years of age, although it is known that functional results and patient satisfaction are lower combined with an increased likelihood of revision compared to older patients. Higher physical activity and patient expectations are a major challenge in this age group. At the same time, the incidence of posttraumatic/postoperative alterations is high, including ligamentous or bony deficiencies, which can make the surgical procedure challenging. In view of these facts conservative treatments and joint sparing procedures should always be considered first. The potential correction of lower-limb deformities and unicompartmental knee arthroplasties need to be carefully evaluated before considering total knee arthroplasty. Only in advanced cases of osteoarthritis in more than one compartment of the knee of with combined ligamentous instability, can a TKA provide satisfactory results in the young patient. However, the strongest predictor of satisfaction is a realistic expectation.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Satisfação do Paciente , Resultado do Tratamento
3.
Orthopade ; 49(12): 1072-1076, 2020 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-33112970

RESUMO

The qualified training of users of medicinal products is enshrined in law by the Medical Devices Act. In this article, a survey and analysis of the training measures for arthroplasty of the large joints offered by distributors of medical devices is carried out. To that end, the internet presence of suppliers of medical devices was evaluated with regard to the training measures on offer, and selected suppliers were sent questionnaires. The presentation of the available training programmes on the websites was incomplete. Even after the amendment of the Medical Devices Act, this has only slightly changed; however, legally required instructions for use were available for all distributors questioned. In some cases, there are large gaps in the range of modern training methods on offer, such as practical instruction, multimedia offerings or visual-haptic training methods.


Assuntos
Artroplastia/educação , Multimídia , Internet , Padrões de Referência
4.
Orthopade ; 49(12): 1049-1055, 2020 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-33112972

RESUMO

As medical devices surgical instruments are important components when performing surgery. They can significantly influence the course and outcome of the surgery. Instruments are mechanically stressed in daily use and resterilized multiple times. The majority of manufacturer documentation for endoprostheses lacks specific information regarding tolerable instrument wear and the maximum number of applications for surgical instruments. So far, there are no mandatory algorithms for the necessity of checking and replacing surgical instruments. The risk of mechanical failure, surface damage and ultimately incidents is illustrated using endoprosthesis instruments as examples.


Assuntos
Próteses e Implantes , Instrumentos Cirúrgicos , Algoritmos
5.
Int Psychogeriatr ; 30(9): 1375-1383, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29559010

RESUMO

ABSTRACTBackground:Cognitive decline is an important complication of joint replacement surgeries in senior people. METHODS: We determined incidence rates of dementia diagnosis following endoprosthetic joint replacement surgery (upper and lower extremities). The observation period covered up to 28 quarters using German claims data comprising 154,604 cases 65 years and older. Effects were controlled for cerebrovascular and vascular risk factors, age, sex, the presence of a diagnosis of delirium, and regular prescription of sedative or analgesic drugs (SAD). RESULTS: The rate of incident dementia diagnoses in people without joint replacement surgery was 21.34 per 1,000 person years, compared with 80.76 incident cases when joint replacement surgery was conducted during the quarter of the incident dementia diagnosis; rates declined to 21.77 incident cases 7 and more quarters after joint replacement surgery had taken place. This pattern was maintained when controlling for delirium diagnosis and regular prescription of SAD. Among 10,563 patients with at least one joint replacement surgery, patients with a diagnosis of delirium in the quarter of the surgery were at increased risk of a dementia diagnosis compared to patients without such a diagnosis (HR=2.00, p < 0.001). CONCLUSION: In people surviving the high-risk phase for dementia immediately after surgery, long-term risk of dementia may reach the level of those without surgery. These findings encourage consequent perioperative management to reduce the risk of dementia as well as prospective studies of potentially beneficial effects of joint replacement surgery on mid- to long-term recovery of mobility and cognition in geriatric patients.


Assuntos
Artroplastia de Substituição/psicologia , Artroplastia de Substituição/estatística & dados numéricos , Delírio/epidemiologia , Demência/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Analgésicos/uso terapêutico , Feminino , Alemanha , Humanos , Revisão da Utilização de Seguros , Estimativa de Kaplan-Meier , Masculino , Modelos de Riscos Proporcionais , Fatores de Risco
6.
Arch Orthop Trauma Surg ; 137(1): 81-87, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27695971

RESUMO

INTRODUCTION: The application of traction in hip arthroscopy is associated with peri-operative complications. Within a therapeutic case series, patient-related factors correlating with high-traction forces during hip arthroscopy and occurring complications should be identified. MATERIALS AND METHODS: In 30 male and 38 female patients (mean age: 44.5 years), intra-operative traction forces were monitored continuously using a specialised measurement device. A multivariate analysis was employed to identify patient-related factors influencing the traction force. Peri-operative complications (follow-up: 12 weeks) were evaluated by performing a single-case analysis. RESULTS: The mean initial force prior to penetration of the capsule ("initial force") was 477 N (men: 517 N; women: 444 N), decreasing after capsulotomy by an average of 17 %. The male gender (p < 0.001), Kellgren and Lawrence radiographic stage (p = 0.037), low minimum joint-space width (p = 0.029) and high body height/weight (p = 0.003/0.037) correlated significantly with higher distraction forces. The patient age and type of anaesthesia (general versus spinal) were not relevant. Complications were observed in ten patients on the first post-operative day. In two of these patients a partial sensory deficit of the lateral cutaneous femoral nerve persisted after 12 weeks. All patients with complications required initial traction forces of >400 N. CONCLUSIONS: The study revealed several patient-specific risk factors correlating with high-traction forces during hip arthroscopy. With view to potential complications, these patient groups require special attention during surgical treatment as well as in future studies.


Assuntos
Artroscopia/efeitos adversos , Articulação do Quadril/cirurgia , Tração/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroscopia/métodos , Estatura , Peso Corporal , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Radiografia , Fatores de Risco , Fatores Sexuais , Adulto Jovem
7.
Acta Orthop Belg ; 82(1): 60-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26984655

RESUMO

Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group: n=42 patients), except for a higher Harris Hip Score in the threaded cup group after five years (p=0.02). After five years, one threaded cup had a mild radiolucent line without further signs of loosening. All other cups of both groups (98.6%) showed a full osseous integration. The cup inclination angle ranged from 41-58° (threaded cups) to 39-77° (press-fit cups). The new threaded cup provides equivalent clinical outcomes and osseous integration but more precise implant positioning compared to the press-fit design. No complications typically ascribed to threaded cups (acetabular fractures, bone resorption, nerve impairment) occurred.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Necrose da Cabeça do Fêmur/cirurgia , Articulação do Quadril/cirurgia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Desenho de Prótese , Adulto , Idoso , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
8.
J Orthop Sci ; 20(6): 1046-52, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26286679

RESUMO

BACKGROUND: Degenerative hip and spine disease are known to frequently coexist. Lumbar spine disorders (LSDs), as opposed to other patient-related factors, are disregarded in the assessment of the clinical outcome after total hip replacement (THR). This prospective study investigates the influence of LSDs on the pre- and postoperative health-related quality of life and functional outcome of patients undergoing THR. METHODS: According to clearly defined criteria, 42 patients scheduled for cementless THR were assigned either to the LSD (13 patients with LSDs) or non-LSD group (29 patients without LSDs). A clinical assessment was performed preoperatively as well as 12, 24 and 60 months postoperatively using the Harris hip score (HHS), the Western Ontario and McMaster University osteoarthritis index (WOMAC) and the 36-item short form health survey (SF-36). RESULTS: The statistical analysis comparing the pre- and postoperative status within both groups showed an ongoing improvement of mean HHS and WOMAC after THR. The non-LSD group had a significantly higher postoperative HHS and WOMAC after 12, 24 and 60 months as well as SF-36 after 24 and 60 months. The LSD group improved significantly in the HHS at 24 and 60 months and the WOMAC at 12, 24 and 60 months postoperatively, whereas the SF-36 improvement was not significant. Comparison of preoperative data in both groups revealed a significantly higher SF-36 in the non-LSD group but no difference between the HHS and WOMAC. At each postoperative assessment, the HHS, WOMAC and SF-36, including its physical and mental health sum scores, were significantly higher in the non-LSD group, except for the WOMAC after 60 months. CONCLUSION: Owing to their crucial impact on hip function scores and health-related quality of life, it is recommended to consider LSDs preoperatively in studies dealing with the clinical outcome after THR.


Assuntos
Artroplastia de Quadril/métodos , Vértebras Lombares , Osteoartrite do Quadril/epidemiologia , Osteoartrite do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Doenças da Coluna Vertebral/epidemiologia , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/reabilitação , Estudos de Casos e Controles , Comorbidade , Feminino , Seguimentos , Humanos , Dor Lombar/diagnóstico por imagem , Dor Lombar/epidemiologia , Dor Lombar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Medição da Dor , Cuidados Pós-Operatórios/métodos , Estudos Prospectivos , Qualidade de Vida , Radiografia , Recuperação de Função Fisiológica , Valores de Referência , Índice de Gravidade de Doença , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/fisiopatologia , Estatísticas não Paramétricas , Resultado do Tratamento
9.
Arch Orthop Trauma Surg ; 135(7): 1027-31, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25920490

RESUMO

INTRODUCTION: Two revisions of broken ß-titanium total hip stems had to be performed in our hospital after 2 and 4 years in situ. Since both fractures were located at the level of a laser engraving, a failure analysis was conducted. MATERIALS AND METHODS: Both retrieved hip stems were disinfected and collected in our retrieval database after patient's signed agreement. Each fragment was macroscopically photographed. Fracture surfaces were analyzed using scanning electron microscopy (SEM). Quantification of element content was conducted using energy dispersive X-ray (EDX) analysis. RESULTS: Both stems show fatigue fracture, as displayed by the lines of rest on the fracture surface. The origin of fracture was identified directly at the laser engraving of the company logo at both stems by means of SEM. The EDX analysis showed an oxygen level beneath the laser engraving about twice as high as in the substrate, causing material embrittlement. CONCLUSIONS: Laser engravings need to be reduced to a minimum of necessary information, and should be placed at locations with minimum mechanical load. Biomechanical analyses are recommended to identify less loaded areas in implant components to avoid such implant failures.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril/efeitos adversos , Osteoartrite do Quadril/cirurgia , Titânio , Idoso , Artroplastia de Quadril/métodos , Desenho de Equipamento , Falha de Equipamento , Feminino , Humanos , Masculino , Microscopia Eletrônica de Varredura , Osteoartrite do Quadril/diagnóstico por imagem , Radiografia , Reoperação
10.
Bioelectromagnetics ; 35(8): 547-58, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25251424

RESUMO

Electromagnetic stimulation is a common therapy used to support bone healing in the case of avascular necrosis of the femoral head. In the present study, we investigated a bipolar induction screw system with an integrated coil. The aim was to analyse the influence of the screw parameters on the electric field distribution in the human femoral head. In addition, three kinds of design parameters (the shape of the screw tip, position of the screw in the femoral head, and size of the screw insulation) were varied. The electric field distribution in the bone was calculated using the finite element software Comsol Multiphysics. Moreover, a validation experiment was set up for an identical bone specimen with an implanted screw. The electric potential of points inside and on the surface of the bone were measured and compared to numerical data. The electric field distribution within the bone was clearly changed by the different implant parameters. Repositioning the screw by a maximum of 10 mm and changing the insulation length by a maximum of 4 mm resulted in electric field volume changes of 16% and 7%, respectively. By comparing the results of numerical simulation with the data of the validation experiment, on average, the electric potential difference of 19% and 24% occurred when the measuring points were at a depth of approximately 5 mm within the femoral bone and directly on the surface of the femoral bone, respectively. The results of the numerical simulations underline that the electro-stimulation treatment of bone in clinical applications can be influenced by the implant parameters.


Assuntos
Parafusos Ósseos , Eletricidade , Campos Eletromagnéticos , Cabeça do Fêmur/efeitos da radiação , Cabeça do Fêmur/cirurgia , Análise de Elementos Finitos , Humanos , Desenho de Prótese
11.
Z Orthop Unfall ; 161(6): 637-647, 2023 Dec.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-35378565

RESUMO

BACKGROUND: The subjective evaluation of the patient's state of health with the help of Patient-reported Outcome Measurements (PROMs) provides valuable information for assessing the treatment outcome and for treatment planning. However, the use of PROMs in the field of arthroplasty is not mandatory, so that there is a lack of standardised recording and interpretation. The present study aims to identify patients, who have not achieved the intended treatment goals with regard to pain, function and quality of life after total knee arthroplasty, more easily in the future on the basis of postoperative PROMs. MATERIAL AND METHODS: Data collection (for 3-month postoperative follow-up) included a standardised clinical follow-up (NU) and a questionnaire of different PROMs (Oxford Knee Score [OKS], OKS Pain Score [OKSS] and EndoCert Risk Score [ERS]). During the specialist follow-up examination, it was decided whether further medical therapy had to be initiated. Accordingly, patients were grouped into four post-treatment categories (NU not required/further diagnostics/new prescription/revision required). RESULTS: For individual scores and questions, there were significant differences between the respective groups of consequences resulting from the follow-up examination. The OKS, OKS Pain Score and the ERS are suitable for detecting thresholds to determine the need for a follow-up examination. The postoperative thresholds of the scores are 24 for the OKS total score, 52 for the OKS pain score and 4 for the ERS pain intensity score. CONCLUSION: In the initial three months after knee arthroplasty, certain PROMs are suitable for identifying patients for whom further diagnostics and therapy are indicated. In particular, the OKS and the pain intensity score of the ERS are suitable for detecting a potentially unfavourable development in rehabilitation after total knee arthroplasty.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Artroplastia do Joelho/métodos , Qualidade de Vida , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Dor/cirurgia , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia
12.
Orthopadie (Heidelb) ; 52(6): 504-508, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37171637

RESUMO

BACKGROUND: The history of total hip arthroplasty dates back to the first half of the twentieth century. Data on hip endoprostheses implanted during the 1960s and 1970s suggest widely varying survival rates of the prosthesis. CASE: A case of a patient who underwent total hip arthroplasty in 1972 using a Sivash prosthesis, developed in 1956 in the former Soviet Union, is presented in this article. The prosthesis has remained unrevised in the patient's body for 50 years and he continues to be widely free of implant-related symptoms. Despite the constrained metal-on-metal design of the implant, which can lead to adverse reactions to metal debris, no elevated systemic metal ion levels were detected. CONCLUSION: The likelihood of encountering patients with prosthesis survival beyond 50 years is still rare. Nevertheless, changing demographics and the steadily improving designs and materials of hip endoprostheses may likely result in such cases.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Masculino , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Próteses Articulares Metal-Metal/efeitos adversos , Desenho de Prótese , Metais
13.
J Orthop Sci ; 17(3): 205-12, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22406866

RESUMO

BACKGROUND: Stress shielding and nonphysiological load transfer after primary or revision total hip replacement (THR) prepare the ground for resorptive bone remodeling. The quality of the bone stock influences the risk of periprosthetic fractures and the severity of future revision surgeries. The question of whether or not bending stiffness and distal screw interlocking influence load transfer of a modular revision hip stem with a solid, hollow, and hollow-slotted stem extension led to the conception of this experimental study. The results were compared with a standard hip stem for primary THR. METHODS: Revision stems were implanted in photoelastically coated composite femora. Cortical strain mapping was conducted before and after insertion of the implants under standardized loading conditions, considering the relevant muscle forces. Statistical analysis was based on a 95% confidence interval and a variance analysis for repeated measurements. RESULTS: Significant stress shielding was observed after insertion of all types of hip stems compared with the intact femora. There was also a marked difference between strain alterations induced by standard and revision hip stems. With revision stems, the most distinct stress shielding effects were registered with the solid stem extension, particularly in the femoral diaphysis. Distal interlocking screws only had a local action on strain pattern and tended to enhance stress shielding at the midstem area when using the more flexible components. CONCLUSION: More flexible revision stems provide a cortical strain pattern of the femur closer to the preoperative status. This may reduce resorptive bone remodeling in the long term. However, any type of revision stem tested in this study caused higher stress shielding than the hip stem for primary THR, especially in the diaphyseal region medially and laterally. With sufficient proximal anchorage, the influence of distal interlocking screws on the femoral strain pattern was localized.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Estresse Mecânico , Fenômenos Biomecânicos , Parafusos Ósseos , Desenho de Prótese , Reoperação
14.
Z Orthop Unfall ; 160(4): 442-454, 2022 08.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-33873223

RESUMO

BACKGROUND: In addition to clinical parameters, the subjective assessment by the patient to evaluate the operative outcome of an arthroplasty is becoming increasingly important. Questionnaires are used to identify patients who have not achieved the treatment goal at an early stage so that further interventions can be indicated. MATERIAL AND METHODS: A questionnaire consisting of different PROMs was completed pre- and 3 months postoperatively by patients who had been treated with a hip arthroplasty. A standardised follow-up examination of these patients was carried out 12 to 16 weeks postoperatively, after which it was determined whether further therapy was necessary to achieve the treatment goal. Different consequences were defined for this. RESULTS: Significant differences were found between the groups of consequences of follow-up examinations over both time points, but also when postoperative scores were considered exclusively. Furthermore, the correlations for the postoperative scores and some consequences of the clinical follow-up for the Oxford Hip Score (OHS), the OHS functional score and the Euroquol-5D show moderate effects. Thus, the collection of these postoperative scores is sufficient to identify potential high risk patients. Based on a receiver operating characteristic (ROC) analysis, threshold values could be determined for these scores, for which a follow-up examination is recommended. CONCLUSION: Patients who could not achieve functional improvement, pain reduction and improvement in quality of life after implantation of a total hip replacement must be identified at an early stage. The results of our study show that with the help of the Oxford Hip Score and Euroquol-5D, which are answered by the patients three months postoperatively, such high risk patients can be identified. This finding is an added value for the further development of the EndoCert certification system and holistic quality assurance in arthroplasties, while the personnel and time effort remain manageable.


Assuntos
Artroplastia de Quadril , Artroplastia de Quadril/efeitos adversos , Certificação , Humanos , Qualidade de Vida , Inquéritos e Questionários , Resultado do Tratamento
15.
Orthopadie (Heidelb) ; 51(7): 564-572, 2022 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-34718833

RESUMO

BACKGROUND: Large femoral defects in late periprosthetic infection (PPI) after total hip arthroplasty (THA) often require the use of large, individual metal endoskeleton-reinforced cement spacers (iMECS). OBJECTIVES: The aim was to record the clinical, radiological and functional results (Harris Hip Score HHS) up to the 2 years after treatment of a PPI using an iMECS. Major patient-specific parameters were to be evaluated with regard to the treatment outcome. MATERIALS AND METHODS: The collective of this single-center retrospective cohort study comprised 29 patients. The mean follow-up was 24.4 months (range: 23.0 to 27.6 months). The absence of infection after endoprosthetic hip joint reconstruction was rated as successful treatment. The two patient groups (successful (S)/not successful (nS)) were compared with regard to gender distribution, the Charlson comorbidity index (CCI), the number of previous septic changes, and the rate of polymicrobial and difficult-to-treat infections. RESULTS: The average CCI in the total collective was 6.4 points. Joint reconstruction was possible in 23 of 29 patients (79%); 2 years after PPI treatment 4 patients were not available for a follow-up examination (2 deceased, 2 unable to participate). At the time of the follow-up, 17 of the 29 patients had received a joint reconstruction and were free of infection, with an average HHS of 75 points. There were no iMECS-associated complications requiring revision. Only the initial CCI (S: 4.1 points; nS: 9.7 points) differed significantly between the patient groups (p < 0.05). CONCLUSIONS: In the case of large femoral defects, iMECS provide secure temporary stabilization. The chance of a successful joint reconstruction is closely related to the individual comorbidities profile.


Assuntos
Artroplastia de Quadril , Infecções Relacionadas à Prótese , Artroplastia de Quadril/efeitos adversos , Fêmur/cirurgia , Humanos , Infecções Relacionadas à Prótese/cirurgia , Reoperação/efeitos adversos , Estudos Retrospectivos
16.
Chirurg ; 92(10): 963-972, 2021 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-33770190

RESUMO

The infection rate after fracture osteosynthesis depends on many factors. The postoperative infection rate after osteosynthesis (inpatient treatment) was between 1.15% and 2.04% for the years 2017-2019. The total number of postoperative wound infections was estimated at around 225,000 annually in 2018. Essential factors for reducing the infection rate after osteosynthesis are the favorable choice of the timing of the operation and the surgical procedure as well as the treatment of relevant secondary diseases. If a postoperative wound infection is suspected critical assessment of the wounds in the postoperative course is essential in order to be able to identify and treat this complication at an early stage. After osteosynthesis, early diagnosis of a peri-implant infection and differentiated surgical and antibiotic treatment are the prerequisites for the best possible treatment success.


Assuntos
Fixação Interna de Fraturas , Infecção da Ferida Cirúrgica , Antibacterianos/uso terapêutico , Humanos , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/tratamento farmacológico , Resultado do Tratamento
17.
J Fungi (Basel) ; 7(6)2021 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-34064002

RESUMO

The treatment of periprosthetic joint infections (PJI), and especially of re-infections, poses a highly complex problem in orthopaedic surgery. While fungal infections are rare, they present a special challenge. The therapy is often protracted and based on limited evidence. A total of 510 hip and knee revision surgeries were analysed for the occurrence of bacterial and fungal PJI. In patients with PJI, the duration of the hospital stay and the incidence of disarticulation of the infected joint were recorded. Out of the analysed revision arthroplasties, 43.5% were due to PJI. Monomicrobial infection occurred in 55.2%, dual microbial infection in 21.4%, and polymicrobial (≥3 different bacterial or fungal species) infection in 17.2% of the cases. Overall, Candida species were detected in 12.4% cases. Candida albicans was the main fungal pathogen. In 6.9% of cases, disarticulation of the joint was the only option to control PJI. The detection of polymicrobial infection more than doubled in follow-up revisions and there was a strong association between detection of Candida infection and disarticulation (OR 9.39). The majority of fungal infections were mixed infections of bacteria and Candida albicans. The choice of a biofilm penetrating antimycotic, e.g., caspofungin, together with a sufficient standard procedure for detection and surgical treatment can help to control the infection situation. Fungal infection often proves to be more difficult to treat than anticipated and is more frequent than expected.

18.
Arch Orthop Trauma Surg ; 130(4): 469-71, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19562357

RESUMO

Here presented is an extremely rare case of a spinal osteomyelitis (L5-S1) with epidural empyema in a non-immunocompromised 62-year-old man caused by Yersinia enterocolitica O:9. The infection occurred acutely and required immediate surgical treatment. Y. enterocolitica was cultured from the empyema fluid, wound swabs of the intervertebral disc L5-S1 and stool cultures. Following the surgical decompression and antibiotic treatment, the patient recovered completely, without neurological deficits. A review of the literature revealed only sparse cases of spondylodiscitis due to other Y. enterocolitica serogroups. To our knowledge, we report here the first case of a spondylodiscitis of the lumbar spine caused by Y. enterocolitica serovar O:9 in a non-immunocompromised patient.


Assuntos
Discite/microbiologia , Yersinia enterocolitica , Antibacterianos/uso terapêutico , Descompressão Cirúrgica , Discite/diagnóstico , Discite/terapia , Espaço Epidural , Humanos , Imunocompetência , Vértebras Lombares/microbiologia , Masculino , Pessoa de Meia-Idade , Yersiniose/complicações , Yersiniose/diagnóstico , Yersiniose/terapia
19.
Clin Biomech (Bristol, Avon) ; 80: 105202, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33129564

RESUMO

BACKGROUND: Cementless modular endoprostheses with tapered fluted stems cover a wide spectrum of femoral defects in reconstructive surgery of the hip. Nevertheless, for these hip stems the recommendations concerning the minimum diaphyseal anchorage distance differ widely. The present experimental study investigated the primary stability of a conical fluted revision stem depending on different types of femoral bone defects. METHODS: Using six fresh frozen human femora, the relative movement of a bi-modular revision stem within the implant-bone interface was examined under cyclic loading conditions. Implant subsidence as well as micromotions at the bone-implant interface were captured with linear variable differential transformers for the intact femora and three different defects ranging from Paprosky type II to type IIIB. FINDINGS: Compared to the intact femur, the infliction of a Paprosky type IIIB defect (3 cm of intact diaphysis) notably increased mean stem subsidence (13-389 µm per 500 load cycles; P = 0.116) but the mean interface micromotion vector sum remained unchanged (50 µm vs. 53 µm). In Paprosky IIIB defects the subsidence component resulting from rotation (horizontal plane) was significantly higher than with the intact femur and a Paprosky II defect (P ≤ 0.041). INTERPRETATION: With optimal bone quality and ideal femur preparation a 3 cm conical fixation was sufficient to meet the set criteria of bony ingrowth in vitro. A conical fixation of 7 cm should be recommended to limit rotational subsidence, especially in case of impaired diaphyseal bone quality or expected difficulties with partial weight-bearing.


Assuntos
Fêmur/cirurgia , Prótese de Quadril , Movimento (Física) , Idoso , Artroplastia de Quadril , Cadáver , Feminino , Fêmur/fisiologia , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Reoperação , Suporte de Carga
20.
J Orthop Surg (Hong Kong) ; 28(3): 2309499020948991, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32909886

RESUMO

PURPOSE: Cementless modular fluted hip stems are commonly used in revision arthroplasty. Nevertheless, there is a wide spectrum of recommendations concerning the minimum bone stock required to enable osseous ingrowth and implant-bone micromotions <100 µm. This experimental study investigated the primary stability of a tapered cementless fluted revision stem depending on different types of bone defects. METHODS: Implant-bone interface movements with a bimodular stem were examined under cyclic axial and torsional loading using composite femora. In four degrees of freedom, the implant subsidence and micromotions were captured with linear variable differential transformers for the intact femora and seven different defects ranging from Paprosky type I to type IIIB. RESULTS: With a 7-cm length of intact diaphysis proximal to the isthmus (Paprosky IIIA), mean implant-bone micromotions of 66 µm occurred. An implant-bone contact zone of only 5 cm (Paprosky IIIA) resulted in micromotions notably over 100 µm and significantly increased subsidence (p < 0.05). With a Paprosky IIIB defect (3 cm of intact diaphysis) rotational instability occurred in all specimens. CONCLUSIONS: Aside from critically increased interfacial micromotions (>100 µm), rotational instability emerged as a mechanism of fixation failure when the implant-bone contact zone was only 5 cm or less. Hence, future studies investigating the implant fixation in the case of femoral bone defects should consider both axial and torsional loading. With regard to the clinical application, our data suggest maintaining 7 cm of diaphyseal implant-bone contact for a safe anchorage of cementless fluted hip revision stems.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Prótese de Quadril , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Reoperação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA