Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 126
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 23(11): 4991-4996, 2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37205843

RESUMO

The omnipresence of hexagonal boron nitride (hBN) in devices embedding two-dimensional materials has prompted it as the most sought after platform to implement quantum sensing due to its testing while operating capability. The negatively charged boron vacancy (VB-) in hBN plays a prominent role, as it can be easily generated while its spin population can be initialized and read out by optical means at room-temperature. But the lower quantum yield hinders its widespread use as an integrated quantum sensor. Here, we demonstrate an emission enhancement amounting to 400 by nanotrench arrays compatible with coplanar waveguide (CPW) electrodes employed for spin-state detection. By monitoring the reflectance spectrum of the resonators as additional layers of hBN are transferred, we have optimized the overall hBN/nanotrench optical response, maximizing thereby the luminescence enhancement. Based on these finely tuned heterostructures, we achieved an enhanced DC magnetic field sensitivity as high as 6 × 10-5 T/Hz1/2.

2.
Radiology ; 305(1): 169-178, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35727152

RESUMO

Background Longitudinal data on the association of quantitative thigh muscle MRI markers with knee osteoarthritis (KOA) outcomes are scarce. These associations are of clinical importance, with potential use for thigh muscle-directed disease-modifying interventions. Purpose To measure KOA-associated longitudinal changes in MRI-derived muscle cross-sectional area (CSA) and adipose tissue and their association with downstream symptom worsening and knee replacement (KR). Materials and Methods In a secondary analysis of the Osteoarthritis Initiative multicenter prospective cohort (February 2004 through October 2015), knees of participants with available good-quality thigh MRI scans at baseline and at least one follow-up visit were included and classified as with and without KOA according to baseline radiographic Kellgren-Lawrence grade of 2 or higher and matched for confounders with use of propensity score matching. An automated deep learning model for thigh MRI two-dimensional segmentation was developed and tested. Markers of muscle CSA and intramuscular adipose tissue (intra-MAT) were measured at baseline and 2nd- and 4th-year follow-up (period 1) and compared between knees with and without KOA by using linear mixed-effect regression models. Furthermore, in knees with KOA, the association of period 1 changes in muscle markers with risk of KR (Cox proportional hazards) and symptom worsening (mixed-effect models) during the 4th to 9th year (period 2) was evaluated. Results This study included 4634 matched thighs (2317 with and 2317 without KOA) of 2344 participants (mean age, 62 years ± 9 [SD]; 1292 women). Compared with those without, knees with KOA had a decrease in quadriceps CSA (mean difference, -8.21 mm2/year; P = .004) and an increase in quadriceps intra-MAT (1.98 mm2/year; P = .007). Decreased CSA and increased intra-MAT of quadriceps during period 1 was predictive of downstream (period 2) KOA symptom worsening (Western Ontario and McMaster Universities Osteoarthritis Index total score: odds ratio, 0.24 [negative association] [P < .001] and 1.38 [P = .012], respectively). Quadriceps CSA changes were negatively associated with higher future KR risk (hazard ratio, 0.70; P < .001). Conclusion Knee osteoarthritis was associated with longitudinal MRI-derived decreased quadriceps cross-sectional area and increased intramuscular adipose tissue. These potentially modifiable risk factors were predictive of downstream symptom worsening and knee replacement. Clinical trial registration no. NCT00080171 © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Osteoartrite do Joelho , Progressão da Doença , Feminino , Humanos , Articulação do Joelho , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Osteoartrite do Joelho/complicações , Osteoartrite do Joelho/diagnóstico por imagem , Estudos Prospectivos , Músculo Quadríceps/diagnóstico por imagem , Exacerbação dos Sintomas , Coxa da Perna/diagnóstico por imagem
4.
Radiology ; 296(3): 521-531, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32633673

RESUMO

Background The overall rate of hip fractures not identified on radiographs but that require surgery (ie, surgical hip fractures) remains unclear in elderly patients who are suspected to have such fractures based on clinical findings. Moreover, the importance of advanced imaging in these patients has not been comprehensively assessed. Purpose To estimate the frequency of radiographically occult hip fracture in elderly patients, to define the higher-risk subpopulation, and to determine the diagnostic performance of CT and bone scanning in the detection of occult fractures by using MRI as the reference standard. Materials and Methods A literature search was performed to identify English-language observational studies published from inception to September 27, 2018. Studies were included if patients were clinically suspected to have hip fracture but there was no radiographic evidence of surgical hip fracture (including absence of any definite fracture or only presence of isolated greater trochanter [GT] fracture). The rate of surgical hip fracture was reported in each study in which MRI was used as the reference standard. The pooled rate of occult fracture, diagnostic performance of CT and bone scanning, and strength of evidence (SOE) were assessed. Results Thirty-five studies were identified (2992 patients; mean age, 76.8 years ± 6.0 [standard deviation]; 66% female). The frequency of radiographically occult surgical hip fracture was 39% (1110 of 2835 patients; 95% confidence interval [CI]: 35%, 43%) in studies of patients with no definite radiographic fracture and 92% (134 of 157 patients; 95% CI: 83%, 98%) in studies of patients with radiographic evidence of isolated GT fracture (moderate SOE). The frequency of occult fracture was higher in patients aged at least 80 years (44%, 529 of 1184), those with an equivocal radiographic report (58%, 71 of 126), and those with a history of trauma (41%, 977 of 2370) (moderate SOE). CT and bone scanning yielded comparable diagnostic performance in the detection of radiographically occult hip fracture (P = .67), with a sensitivity of 79% and 87%, respectively (low SOE). Conclusion Elderly patients with acute hip pain and negative or equivocal findings at initial radiography have a high frequency of occult hip fractures. Therefore, the performance of advanced imaging (preferably MRI) may be clinically appropriate in all such patients. © RSNA, 2020 Online supplemental material is available for this article.


Assuntos
Fraturas Fechadas/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas Fechadas/epidemiologia , Fraturas do Quadril/epidemiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
5.
Radiographics ; 40(7): 1932-1937, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32976062

RESUMO

Machine learning (ML) algorithms have demonstrated high diagnostic accuracy in identifying and categorizing disease on radiologic images. Despite the results of initial research studies that report ML algorithm diagnostic accuracy similar to or exceeding that of radiologists, the results are less impressive when the algorithms are installed at new hospitals and are presented with new images. This phenomenon is potentially the result of selection bias in the data that were used to develop the ML algorithm. Selection bias has long been described by clinical epidemiologists as a key consideration when designing a clinical research study, but this concept has largely been unaddressed in the medical imaging ML literature. The authors discuss the importance of selection bias and its relevance to ML algorithm development to prepare the radiologist to critically evaluate ML literature for potential selection bias and understand how it might affect the applicability of ML algorithms in real clinical environments. ©RSNA, 2020.


Assuntos
Diagnóstico por Imagem , Aprendizado de Máquina , Viés de Seleção , Humanos , Terminologia como Assunto
6.
Emerg Radiol ; 27(4): 367-375, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32643070

RESUMO

PURPOSE: To (1) develop a deep learning system (DLS) using a deep convolutional neural network (DCNN) for identification of pneumothorax, (2) compare its performance to first-year radiology residents, and (3) evaluate the ability of a DLS to augment radiology residents by detecting missed pneumothoraces. METHODS: This was a retrospective study performed in September 2018. We obtained 112,120 chest radiographs (CXRs) from the NIH ChestXray14 database, of which 4360 cases (4%) were labeled as pneumothorax by natural language processing. We utilized 111,518 CXRs to train and validate the ResNet-152 DCNN pretrained on ImageNet to identify pneumothorax. DCNN testing was performed on a hold-out set of 602 CXRs, whose groundtruth was determined by a cardiothoracic radiologist. Two first-year radiology residents evaluated the test CXRs for presence of pneumothorax. Receiver operating characteristic (ROC) curves were generated for each evaluator with area under the curve (AUC) compared using the DeLong parametric method. RESULTS: The DCNN achieved AUC of 0.841 for identification of pneumothorax at a rate of 1980 images/min. In contrast, both first-year residents achieved significantly higher AUCs of 0.942 and 0.905 (p < 0.01 for both compared to DCNN), but at a slower rate of two images/min. The DCNN identified 3 of 31 (9.7%) additional pneumothoraces missed by at least one of the residents. CONCLUSION: A DLS for pneumothorax identification had lower AUC than 1st-year radiology residents, but interpreted images > 1000× as fast and identified 3 additional pneumothoraces missed by the residents. Our findings suggest that DLS could augment radiologists-in-training to identify potential urgent findings.


Assuntos
Competência Clínica , Serviço Hospitalar de Emergência , Redes Neurais de Computação , Pneumotórax/diagnóstico por imagem , Radiografia Torácica , Erros de Diagnóstico/prevenção & controle , Medicina de Emergência/educação , Humanos , Internato e Residência , Radiologia/educação , Estudos Retrospectivos
7.
J Digit Imaging ; 33(4): 1053-1057, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32372328

RESUMO

Since its 2010 launch, Instagram has rapidly risen to become one of the leading social media in the world, with more than one billion monthly users. Within the field of radiology, perhaps because of the image-weighted nature of the platform, several prominent organizations host Instagram accounts, including the Radiological Society of North America, American Roentgen Ray Society, American College of Radiology, and the American Board of Radiology. We started our own Instagram account in January 2016 because of the popularity of this social media platform among medical students. Our website contains over 260,000 images and is aimed at educating physicians, technologists, and nurses around the world on radiology, with an emphasis on body computed tomography. Given our varied selection of radiology resources, we were curious as to which posts perform best on Instagram and set out how to best characterize the interest in these posts. Our results point to an approach that can aid radiology educators who use social media, particularly Instagram, in producing popular content.


Assuntos
Radiologia , Mídias Sociais , Humanos , América do Norte , Estados Unidos
9.
Radiology ; 290(2): 435-445, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30457479

RESUMO

Purpose To investigate the diagnostic performance of three-dimensional (3D) MRI for depicting meniscal injuries of the knee by using surgery as the standard of reference. Materials and Methods A literature search was performed to identify original studies published between 1985 and 2017. Summary receiver operating characteristic curve and sensitivity analyses were performed to compare the diagnostic performance of 3D versus two-dimensional (2D) MRI for the assessment of knee meniscal injuries and to evaluate the impact of relevant covariates on the diagnostic performance for assessment of knee meniscal injuries. Results Of identified records, 31 studies (1743 3D knee MRI examinations) were included (23 studies also reported the results of 2D MRI). All studies before 2008 used gradient-echo (GRE) sequences, whereas all studies after 2011 used fast spin-echo (FSE) sequences. By comparing FSE and GRE sequences with 2D MRI, pooled estimate of sensitivity (90.0%; P = .2 and 90.1%; P = .2 vs 88.5%) and pooled estimate of specificity (91%; P = .3 and 89.8% vs 90.1%; P = .7) were comparable. The 3D FSE sequences demonstrated similar diagnostic performance as 3D GRE sequences, except for slightly improved sensitivity for depicting lateral meniscal injuries (FSE, 84.6%; GRE, 75%; P = .01). The specificity of 3D sequences improved when multiplanar reformatting was performed (P = .02). Conclusion Both three-dimensional (3D) fast spin-echo (FSE) and 3D gradient-echo (GRE) sequences had similar diagnostic performance as two-dimensional sequences, with slight superior sensitivity of 3D FSE sequences compared with 3D GRE sequences for depicting lateral meniscal injuries of the knee. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Meniscos Tibiais/diagnóstico por imagem , Lesões do Menisco Tibial/diagnóstico por imagem , Adulto , Humanos , Masculino , Adulto Jovem
10.
Radiology ; 293(1): 107-114, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31453766

RESUMO

Background Few data exist on the long-term risk prediction of elevated left ventricular (LV) mass quantified by MRI for cardiovascular (CV) events in a contemporary, ethnically diverse cohort. Purpose To assess the long-term impact of elevated LV mass on CV events in a prospective cohort study of a multiethnic population in relationship to risk factors and coronary artery calcium (CAC) score. Materials and Methods The Multi-Ethnic Study of Atherosclerosis, or MESA (ClinicalTrials.gov: NCT00005487), is an ongoing prospective multicenter population-based study in the United States. A total of 6814 participants (age range, 45-84 years) free of clinical CV disease at baseline were enrolled between 2000 and 2002. In 4988 participants (2613 [52.4%] women; mean age, 62 years ± 10.1 [standard deviation]) followed over 15 years for CV events, LV mass was derived from cardiac MRI at baseline enrollment by using semiautomated software at a central core laboratory. Cox proportional hazard models, Kaplan-Meier curves, and z scores were applied to assess the impact of LV hypertrophy. Results A total of 290 participants had hard coronary heart disease (CHD) events (207 myocardial infarctions [MIs], 95 CHD deaths), 57 had other CV disease-related deaths, and 215 had heart failure (HF). LV hypertrophy was an independent predictor of hard CHD events (hazard ratio [HR]: 2.7; 95% confidence interval [CI]: 1.9, 3.8), MI (HR: 2.8; 95% CI: 1.8, 4.0), CHD death (HR: 4.3; 95% CI: 2.5, 7.3), other CV death (HR: 7.5; 95% CI: 4.2, 13.5), and HF (HR: 5.4; 95% CI: 3.8, 7.5) (P < .001 for all end points). LV hypertrophy was a stronger predictor than CAC for CHD death, other CV death, and HF (z scores: 5.4 vs 3.4, 6.8 vs 2.4, and 9.7 vs 3.2 for LV hypertrophy vs CAC, respectively). Kaplan-Meier analysis demonstrated an increased risk of CV events in participants with LV hypertrophy, particularly after 5 years. Conclusion Elevated left ventricular mass was strongly associated with hard coronary heart disease events, other cardiovascular death, and heart failure over 15 years of follow-up, independent of traditional risk factors and coronary artery calcium score. © RSNA, 2019 See also the editorial by Hanneman in this issue.


Assuntos
Etnicidade , Insuficiência Cardíaca/epidemiologia , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/epidemiologia , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Aterosclerose , Estudos de Coortes , Comorbidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Risco , Fatores de Risco , Estados Unidos/epidemiologia
11.
Eur Radiol ; 29(9): 4660-4669, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30762111

RESUMO

OBJECTIVES: To evaluate the added value of diffusion-weighted imaging (DWI) on MRI in differentiating serous from mucin-producing pancreatic cystic neoplasms (PCNs). METHODS: One hundred seventeen patients with PCN measuring ≥ 10 mm were included. Three readers independently evaluated MRI with and without the use of apparent diffusion coefficient (ADC). Logistic regression was used to analyze whether confidence scores were different with the use of different image sets. Diagnostic performance with and without ADC was compared. RESULTS: DWI/ADC improved confidence in 44.8%, 73.6%, and 78.2% of patients by the three readers in distinguishing serous from mucin-producing PCNs. The use of ADC increased the probability of a higher confidence in the differentiation as compared to morphological imaging for all three readers (p < 0.001). Odds ratio for increase in the diagnostic confidence with the use of ADC for the three readers with decreasing years of experience were 5.8, 6.8, and 12.7. The diagnostic accuracy of morphological MRI with ADC was higher than that without ADC for two of three readers with lesser experience (87.2% vs. 80.8%; 91.5% vs. 80.8%). CONCLUSION: DWI may have added value as a complementary tool to conventional morphological MRI in differentiating between serous and mucin-producing PCNs with possibly greater value for readers with less experience in reading abdominal MRI. KEY POINTS: • Optimal management of PCNs requires differentiation of serous from mucin-producing PCNs. • ADC measurements allow increased confidence in differentiating serous from mucin-producing PCNs. • ADC measurements increase the accuracy in diagnosing serous versus mucin-producing PCNs.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Pancreáticas/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mucinas , Pâncreas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
12.
Radiology ; 289(1): 71-82, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30015587

RESUMO

Purpose To determine the diagnostic performance of three-dimensional (3D) MRI for the depiction and characterization of cartilage defects within the knee joint by using arthroscopy and/or open surgery as the standard of reference. Materials and Methods A systematic literature search was performed to extract diagnostic studies published between January 1985 and October 2017. Two independent investigators assessed the methodologic quality of each study by using Quality Assessment of Diagnostic Accuracy Studies 2. Bivariate random-effects model was used to compare the diagnostic odds ratio (DOR) of 3D and two-dimensional (2D) MRI for helping to detect knee cartilage defects and to assess the effect of relevant covariates on diagnostic performance of 3D MRI. Meta-regression analysis was performed to assess DOR of 3D MRI during the last 3 decades. Results Twenty-seven studies (composed of 1710 MRI examinations) were included. Of those, 16 (59%) studies compared the diagnostic performance of 3D and 2D MRI. The diagnostic performance of 3D MRI statistically significantly improved over the last 3 decades (P = .003). Three-dimensional MRI obtained by using 3.0-T field strength had higher DOR relative to 1.5-T or lower field strength (relative DOR, 4.05; P = .01). Three-dimensional multiplanar reformation was associated with higher specificity (P = .001) compared with conventional axial, sagittal, and coronal 2D MRI planes. Three-dimensional fast-spin-echo sequences provided higher sensitivity and specificity (P < .05) than did 2D MRI. Conclusion Three-dimensional MRI currently provides comparable diagnostic performance to two-dimensional MRI, with improvement in diagnostic performance achieved by using 3.0-T field strength, three-dimensional fast-spin-echo sequences, and multiplanar reformation. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Doenças das Cartilagens/diagnóstico por imagem , Imageamento Tridimensional/estatística & dados numéricos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cartilagem Articular/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Razão de Chances , Estudos Retrospectivos , Adulto Jovem
13.
Radiology ; 289(3): 641-648, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30129902

RESUMO

Purpose To compare epicardial fat in patients with arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) with that in healthy subjects. Materials and Methods In this retrospective study, cardiac CT scans in 44 patients with ARVD/C (mean age, 39 years ± 12; 23 men) were compared with those in 45 control group participants between January 2008 and July 2015. Volumes of intrathoracic adipose tissue, mediastinal adipose tissue (MAT), and total epicardial adipose tissue (EAT) were quantified. EAT was subdivided into three regions-right ventricular (RV) EAT, left ventricular (LV) EAT, and peri-atrial EAT (atrial EAT)-and normalized to MAT for all regions. Logistic regression and receiver operating characteristic analysis were performed to evaluate the association between epicardial fat with the diagnosis of ARVD/C. Results Total EAT volume was higher in patients with ARVD/C than in healthy control group participants (median, 98 mL vs 76 mL, respectively; P = .04). Regionally, LV and RV EAT volumes were higher in patients with ARVD/C than in control group participants, most notably when indexed to MAT (median LV EAT index: 0.49 vs 0.15, respectively; median RV EAT index: 0.91 vs 0.52; P ˂ .0005 for both). The optimal cutoff for diagnosis of ARVD/C was an LV EAT index of 0.24, with a sensitivity and specificity of 91% and 71%, respectively. Atrial EAT volume and total intrathoracic adipose tissue volume were not different between groups. RV diameter showed a positive correlation with total EAT index and LV EAT index (r = 0.21, P = .05 and r = 0.33, P = .002, respectively). Conclusion Higher amounts of right ventricular and left ventricular epicardial fat are found in hearts with arrhythmogenic right ventricular dysplasia/cardiomyopathy, particularly adjacent to the left ventricle, which correlates with disease severity and helps differentiate patients from healthy subjects. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Pericárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
AJR Am J Roentgenol ; 211(1): W52-W63, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29792743

RESUMO

OBJECTIVE: The purpose of this study is to determine the diagnostic performance of MRI and MR arthrography for depicting ligamentum teres lesions. MATERIALS AND METHODS: A literature search was performed. Original studies reporting the diagnostic accuracy of MRI examinations for the depiction of ligamentum teres lesions were included. RESULTS: Eight studies entailing 1456 MRI examinations were included (frequency of median ligamentum teres injury, 25.9%; interquartile range, 14.1-45.3%). Two studies reported the results of unenhanced MRI examinations, and their diagnostic performance could not be estimated. Sensitivity, specificity, and diagnostic odds ratio (DOR) of all MRI examinations were 64.7%, 86.9%, and 12.2, respectively, whereas the sensitivity, specificity, and DOR of MR arthrography examinations were 82.2%, 88.6%, and 35.9, respectively. The heterogeneity (I2) for all MRI and MR arthrography examinations was 92.3% and 88.2%, respectively. Five blinded MR arthrography studies with 643 MR arthrography examinations found an appropriate threshold effect for summary ROC construction (AUC, 0.95). The summary estimate of these studies yielded a sensitivity of 87.8%, a specificity of 91%, and DOR of 73.1. The heterogeneity (I2) for this group was 64.3%. In patients with low pretest probability (25%), MR arthrography enabled the exclusion of ligamentum teres lesion (postprobability for a negative result, 4%; negative likelihood ratio, 0.13). CONCLUSION: MR arthrography can depict ligamentum teres lesions with high accuracy. However, its diagnostic performance for differentiating various types of ligamentum teres lesions (partial, complete ligamentum teres tears, and hypertrophic ligamentum teres), as well as the diagnostic performance of unenhanced MRI for the depiction of ligamentum teres lesions, is yet to be determined because of the paucity of reported data in the literature.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Ligamentos Redondos/diagnóstico por imagem , Diagnóstico Diferencial , Articulação do Quadril/patologia , Humanos , Ligamentos Redondos/patologia , Sensibilidade e Especificidade
15.
Ann Intern Med ; 164(6): 417-24, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26830055

RESUMO

BACKGROUND: Iodine contrast media are essential components of many imaging procedures. An important potential side effect is contrast-induced nephropathy (CIN). PURPOSE: To compare CIN risk for contrast media within and between osmolality classes in patients receiving diagnostic or therapeutic imaging procedures. DATA SOURCES: PubMed, EMBASE, Cochrane Library, Clinical Trials.gov, and Scopus through June 2015. STUDY SELECTION: Randomized, controlled trials that reported CIN-related outcomes in patients receiving low-osmolar contrast media (LOCM) or iso-osmolar contrast media for imaging. DATA EXTRACTION: Independent study selection and quality assessment by 2 reviewers and dual extraction of study characteristics and results. DATA SYNTHESIS: None of the 5 studies that compared types of LOCM reported a statistically significant or clinically important difference among study groups, but the strength of evidence was low. Twenty-five randomized, controlled trials found a slight reduction in CIN risk with the iso-osmolar contrast media agent iodixanol compared with a diverse group of LOCM that just reached statistical significance in a meta-analysis (pooled relative risk, 0.80 [95% CI, 0.65 to 0.99]; P = 0.045). This comparison's strength of evidence was moderate. In a meta regression of randomized, controlled trials of iodixanol, no relationship was found between route of administration and comparative CIN risk. LIMITATIONS: Few studies compared LOCM. Procedural details about contrast administration were not uniformly reported. Few studies specified clinical indications or severity of baseline renal impairment. CONCLUSION: No differences were found in CIN risk among types of LOCM. Iodixanol had a slightly lower risk for CIN than LOCM, but the lower risk did not exceed a criterion for clinical importance. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.


Assuntos
Meios de Contraste/efeitos adversos , Nefropatias/induzido quimicamente , Nefropatias/epidemiologia , Medicina Baseada em Evidências , Humanos , Incidência , Concentração Osmolar , Fatores de Risco , Ácidos Tri-Iodobenzoicos/efeitos adversos
16.
Ann Intern Med ; 164(6): 406-16, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26830221

RESUMO

BACKGROUND: N-acetylcysteine, sodium bicarbonate, statins, and ascorbic acid have been studied for reducing contrast-induced nephropathy (CIN). PURPOSE: To evaluate the comparative effectiveness of interventions to reduce CIN in adults receiving contrast media. DATA SOURCES: MEDLINE, EMBASE, Cochrane Library, ClinicalTrials.gov, and Scopus databases through June 2015. Risk of bias and overall strength of evidence (SOE) of studies were assessed. STUDY SELECTION: Randomized, controlled trials of N-acetylcysteine, sodium bicarbonate, statins, or ascorbic acid that used intravenous (IV) or intra-arterial contrast media and defined CIN with enough data for meta-analysis. DATA EXTRACTION: Two reviewers independently extracted data and assessed study quality. DATA SYNTHESIS: Low-dose N-acetylcysteine plus IV saline compared with IV saline (risk ratio [RR], 0.75 [95% CI, 0.63 to 0.89]; low SOE), N-acetylcysteine plus IV saline compared with IV saline in patients receiving low-osmolar contrast media (RR, 0.69 [CI, 0.58 to 0.84]; moderate SOE), and statins plus N-acetylcysteine plus IV saline versus N-acetylcysteine plus IV saline (RR, 0.52 [CI, 0.29 to 0.93]; low SOE) had clinically important and statistically significant benefits. The following 3 comparisons suggested a clinically important difference that was not statistically significant: sodium bicarbonate versus IV saline in patients receiving low-osmolar contrast media (RR, 0.65 [CI, 0.33 to 1.25]; low SOE), statins plus IV saline versus IV saline (RR, 0.68 [CI, 0.39 to 1.20]; low SOE), and ascorbic acid versus IV saline (RR, 0.72 [CI, 0.48 to 1.01]; low SOE). Strength of evidence was generally insufficient for comparisons of the need for renal replacement, cardiac events, and mortality. LIMITATION: Too few studies were done in patients receiving IV contrast media. CONCLUSION: The greatest reduction in CIN was seen with N-acetylcysteine plus IV saline in patients receiving LOCM and with statins plus N-acetylcysteine plus IV saline. PRIMARY FUNDING SOURCE: Agency for Healthcare Research and Quality.


Assuntos
Meios de Contraste/efeitos adversos , Nefropatias/induzido quimicamente , Nefropatias/prevenção & controle , Acetilcisteína/uso terapêutico , Antioxidantes/uso terapêutico , Ácido Ascórbico/uso terapêutico , Meios de Contraste/administração & dosagem , Sequestradores de Radicais Livres/uso terapêutico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Infusões Intra-Arteriais , Infusões Intravenosas , Razão de Chances , Bicarbonato de Sódio/uso terapêutico , Cloreto de Sódio/uso terapêutico , Estados Unidos
17.
J Digit Imaging ; 30(6): 732-737, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28560509

RESUMO

The purpose of this study was to determine the diagnostic accuracy of an iPhone for evaluation of the coronary arteries on coronary CT angiography (CTA) in comparison to a standard clinical workstation. Fifty coronary CTA exams were selected to include a range of normal and abnormal cases including both coronary artery disease (CAD) of varying severity and coronary artery anomalies. Two cardiac radiologists reviewed each exam on a standard clinical workstation initially and then on an iPhone 6 after a washout period. Coronary stenosis was evaluated on a 4-point scale and presence of coronary anomalies was recorded. Two additional cardiac radiologists reviewed all cases in consensus on the standard workstation and these results were used as the reference standard. When reader results were compared to the reference standard, there was no significant difference in agreement for per-vessel stenosis scores using either the iPhone or standard clinical workstation. The intraobserver intertechnology agreement on a per-vessel basis for obstructive CAD were 97.4% (299/307, kappa = 0.777) and 97.5% (317/325, kappa = 0.804) for the two readers. All cases of coronary anomalies were identified by both readers regardless of the device used. Coronary CTA examinations can be interpreted on a smartphone with diagnostic accuracy comparable to a standard workstation. 3D visualization app on the iPhone may facilitate urgent coronary CTA review when a workstation is not available.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Anomalias dos Vasos Coronários/diagnóstico por imagem , Smartphone , Telemedicina/instrumentação , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Telemedicina/métodos
18.
Radiology ; 278(3): 714-22, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26485617

RESUMO

PURPOSE: To evaluate age-related left ventricular (LV) remodeling during longitudinal observation of a large cohort of asymptomatic individuals who were free of clinical cardiovascular disease at baseline. MATERIALS AND METHODS: The applicable institutional review boards approved this study, and all participants gave informed consent. Cardiac magnetic resonance (MR) imaging was used to identify longitudinal changes in LV structure and function in 2935 participants who underwent baseline and follow-up cardiac MR imaging in the Multi-Ethnic Study of Atherosclerosis. Participants were free of clinical cardiovascular disease at baseline. Participants who experienced an incident coronary heart disease event were excluded. Data were analyzed with multivariable mixed-effects regression models in which the outcome was cardiac MR imaging measurement, and the covariates included follow-up time and cardiac risk factors. RESULTS: Participants were aged 54-94 years at follow-up, and 53% of the participants were women. Median time between baseline and follow-up cardiac MR imaging was 9.4 years. Over this period, LV mass increased in men and decreased slightly in women (8.0 and -1.6 g per decade, respectively; P < .001). In both men and women, LV end-diastolic volume decreased (-9.8 and -13.3 mL per decade, respectively; P < .001), stroke volume decreased (-8.8 and -8.6 mL per decade, respectively; P < .001), and mass-to-volume ratio increased (0.14 and 0.11 g/mL per decade, respectively; P < .001). Change in LV mass was positively associated with systolic blood pressure and body mass index and negatively associated with treated hypertension and high-density lipoprotein cholesterol level. In men, the longitudinal LV mass increase was in contrast to a cross-sectional pattern of LV mass decrease. CONCLUSION: As patients age, the LV responds differently in its mass and volume between men and women, although both men and women experience increased concentric LV remodeling with age. In men, the opposition of longitudinal and cross-sectional changes in LV mass highlights the importance of longitudinal study.


Assuntos
Aterosclerose/diagnóstico , Aterosclerose/etnologia , Imageamento por Ressonância Magnética/métodos , Remodelação Ventricular , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aterosclerose/epidemiologia , Técnicas de Imagem de Sincronização Cardíaca , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Estados Unidos/epidemiologia
19.
Skeletal Radiol ; 45(4): 437-46, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26659662

RESUMO

OBJECTIVES: Using four-dimensional CT scan (4DCT), we aimed at showing the kinematics of scapholunate (SL) interval in asymptomatic wrists in comparison with symptomatic contralateral wrists with inconclusive radiographic findings. METHODS: This is an IRB approved, HIPPA compliant, retrospective study. Patients suspected of SL interosseous ligament (SLIL) injuries were referred for further evaluation of chronic wrist pain (>3 months). Twelve wrists (11 subjects) with chronic symptoms and inconclusive plain radiographs and 10 asymptomatic wrists (in 10 different subjects) were scanned using 4DCT. The minimum SL interval was measured during three wrist motions: relaxed-to-clenched fist, flexion-to-extension, and radial-to-ulnar-deviation. Changes were recorded using double-oblique multiplanar reformation technique. RESULTS: We extracted the normal limits of the SL interval as measured by dynamic CT scanning during active motion in asymptomatic wrists. In asymptomatic wrists, the average SL interval was observed to be smaller than 1 mm during all motions. In symptomatic wrists, during exams performed with clenched fist (SL interval (mean ± SD) = 2.53 ± 1.19 mm), extension (2.54 ± 1.48 mm) or ulnar deviation (2.06 ± 1.12 mm), the average SL interval was more than 2 mm. In contrast to symptomatic wrists, no significant change in SL interval measurements was detected during wrist motions in asymptomatic wrists. There was a mild to moderate correlation between SL interval change and presence/absence of symptoms (point-biserial correlation coefficients: 0.29-0.55). CONCLUSION: In patients with wrist pain suspicious for SLIL injury and inconclusive radiographs, SL interval increase can be detected with 4DCT in the symptomatic wrist compared to the asymptomatic wrist.


Assuntos
Tomografia Computadorizada Quadridimensional , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Ligamentos Articulares/lesões , Traumatismos do Punho/diagnóstico por imagem , Traumatismos do Punho/fisiopatologia , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiopatologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Osso Semilunar/diagnóstico por imagem , Osso Semilunar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Amplitude de Movimento Articular/fisiologia , Estudos Retrospectivos , Osso Escafoide/diagnóstico por imagem , Osso Escafoide/fisiopatologia
20.
Knee Surg Sports Traumatol Arthrosc ; 24(9): 3021-3028, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25941043

RESUMO

PURPOSE: To test the inter-observer and inter-method reliability among the measures suggesting patellofemoral joint disorder on both CT and MRI in the same subject and find possible association with internal derangements of the patellofemoral joint on MRI. METHODS: Institutional review board approval was obtained with waiver of the informed consent in this HIPPA-compliant study. CT and MRI were evaluated in 32 knees in 32 respective subjects (10 men/22 women, mean age 38 ± 19 years). Three trained observers assessed tibial tuberosity-trochlear groove (TT-TG) distance, trochlear angle and trochlear depth on both CT and MRI. Intra-class correlation coefficient (ICC) was used to evaluate inter-observer and inter-method reliability. Two radiologists' consensus reading was used to evaluate their association with soft tissue abnormalities of the patellofemoral joint. Chi-square test was used to assess the statistical significance of the qualitative variables. RESULTS: There was an excellent inter-observer reliability (ICC for CT >0.89 and for MRI >0.90) and inter-method reliability (ICC >0.86) for all the quantitative measurements. There was a significant association between increased TT-TG distance value on MR imaging and lateral facet patellar cartilage abnormality and joint effusion (p < 0.05). CONCLUSION: Quantitative trochlear parameters can be reliably calculated on MRI, and an abnormal TT-TG distance is the most useful measurement among various static MR imaging parameters to correlate with patellar chondrosis and joint effusion. TT-TG distance should be reported in patellofemoral pain syndrome patients. LEVEL OF EVIDENCE: IV.


Assuntos
Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Imageamento por Ressonância Magnética , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/fisiopatologia , Tomografia Computadorizada por Raios X , Adulto , Doenças das Cartilagens/diagnóstico por imagem , Doenças das Cartilagens/fisiopatologia , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Síndrome da Dor Patelofemoral/diagnóstico por imagem , Síndrome da Dor Patelofemoral/fisiopatologia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA