RESUMO
BACKGROUND: Ventricular arrhythmias (VAs) can occur after continuous flow left ventricular assist device (LVAD) implantation as a single arrhythmic event or as electrical storm (ES) with multiple repetitive VA episodes. OBJECTIVE: We aimed at analyzing the incidence, predictors, and clinical impact of ES in LVAD recipients. METHODS: Patients analyzed were those included in the multicenter ASSIST-ICD observational study. ES was consensually defined as occurrence of ≥3 separate episodes of sustained VAs within a 24-hour interval. RESULTS: Of 652 patients with an LVAD, 61 (9%) presented ES during a median follow-up period of 9.1 (interquartile range [IQR] 2.5-22.1) months. The first ES occurred after 17 (IQR 4.0-56.2) days post LVAD implantation, most of them during the first month after the device implantation (63%). The incidence then tended to decrease during the initial years of follow-up and increased again after the third year post LVAD implantation. History of VAs before LVAD implantation and heart failure duration > 84 months were independent predictors of ES. The occurrence of ES was associated with an increased early mortality since 20 patients (33%) died within the first 2 weeks of ES. Twenty-two patients (36.1%) presented at least 1 recurrence of ES, occurring 43.0 (IQR 8.0-69.0) days after the initial ES. Patients experiencing ES had a significantly lower 1-year survival rate than did those free from ES (log-rank, P = .039). CONCLUSION: There is a significant incidence of ES in patients with an LVAD. The short-term mortality after ES is high, and one-third of patients will die within 15 days. Whether radiofrequency ablation of arrhythmias improves outcomes would require further studies.