Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Medicina (Kaunas) ; 60(4)2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38674168

RESUMO

The application of cardiac magnetic resonance (CMR) imaging in clinical practice has grown due to technological advancements and expanded clinical indications, highlighting its superior capabilities when compared to echocardiography for the assessment of myocardial tissue. Similarly, the utilization of implantable cardiac electronic devices (CIEDs) has significantly increased in cardiac arrhythmia management, and the requirements of CMR examinations in patients with CIEDs has become more common. However, this type of exam often presents challenges due to safety concerns and image artifacts. Until a few years ago, the presence of CIED was considered an absolute contraindication to CMR. To address these challenges, various technical improvements in CIED technology, like the reduction of the ferromagnetic components, and in CMR examinations, such as the introduction of new sequences, have been developed. Moreover, a rigorous protocol involving multidisciplinary collaboration is recommended for safe CMR examinations in patients with CIEDs, emphasizing risk assessment, careful monitoring during CMR, and post-scan device evaluation. Alternative methods to CMR, such as computed tomography coronary angiography with tissue characterization techniques like dual-energy and photon-counting, offer alternative potential solutions, although their diagnostic accuracy and availability do limit their use. Despite technological advancements, close collaboration and specialized staff training remain crucial for obtaining safe diagnostic CMR images in patients with CIEDs, thus justifying the presence of specialized centers that are equipped to handle these type of exams.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/normas , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/instrumentação , Arritmias Cardíacas/diagnóstico por imagem
2.
Medicina (Kaunas) ; 60(7)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-39064511

RESUMO

Mitral regurgitation (MR) is a broadly diffuse valvular heart disease (VHD) with a significant impact on the healthcare system and patient prognosis. Transcatheter mitral valve interventions (TMVI) are now well-established techniques included in the therapeutic armamentarium for managing patients with mitral regurgitation, either primary or functional MR. Even if the guidelines give indications regarding the correct management of this VHD, the wide heterogeneity of patients' clinical backgrounds and valvular and heart anatomies make each patient a unique case, in which the appropriate device's selection requires a multimodal imaging evaluation and a multidisciplinary discussion. Proper pre-procedural evaluation plays a pivotal role in judging the feasibility of TMVI, while a cooperative work between imagers and interventionalist is also crucial for procedural success. This manuscript aims to provide an exhaustive overview of the main parameters that need to be evaluated for appropriate device selection, pre-procedural planning, intra-procedural guidance and post-operative assessment in the setting of TMVI. In addition, it tries to give some insights about future perspectives for structural cardiovascular imaging.


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Imagem Multimodal , Humanos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Imagem Multimodal/métodos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/normas , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/instrumentação
3.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38674259

RESUMO

Background and Objectives: Cardiac magnetic resonance (CMR) imaging has become an essential instrument in the study of cardiomyopathies; it has recently been integrated into the diagnostic workflow for cardiac amyloidosis (CA) with remarkable results. An additional emerging role is the stratification of the arrhythmogenic risk by scar analysis and the possibility of merging these data with electro-anatomical maps. This is made possible by using a software (ADAS 3D, Galgo Medical, Barcelona, Spain) able to provide 3D heart models by detecting fibrosis along the whole thickness of the myocardial walls. Little is known regarding the applications of this software in the wide spectrum of cardiomyopathies and the potential benefits have yet to be discovered. In this study, we tried to apply the ADAS 3D in the context of CA. Materials and Methods: This study was a retrospectively analysis of consecutive CMR imaging of patients affected by CA that were treated in our center (Marche University Hospital). Wherever possible, the data were processed with the ADAS 3D software and analyzed for a correlation between the morphometric parameters and follow-up events. The outcome was a composite of all-cause mortality, unplanned cardiovascular hospitalizations, sustained ventricular arrhythmias (VAs), permanent reduction in left ventricular ejection fraction, and pacemaker implantation. The secondary outcomes were the need for a pacemaker implantation and sustained VAs. Results: A total of 14 patients were deemed eligible for the software analysis: 8 patients with wild type transthyretin CA, 5 with light chain CA, and 1 with transthyretin hereditary CA. The vast majority of imaging features was not related to the composite outcome, but atrial wall thickening displayed a significant association with both the primary (p = 0.003) and the secondary outcome of pacemaker implantation (p = 0.003). The software was able to differentiate between core zones and border zones of scars, with the latter being the most extensively represented in all patients. Interestingly, in a huge percentage of CMR images, the software identified the highest degree of core zone fibrosis among the epicardial layers and, in those patients, we found a higher incidence of the primary outcome, without reaching statistical significance (p = 0.18). Channels were found in the scar zones in a substantial percentage of patients without a clear correlation with follow-up events. Conclusions: CMR imaging plays a pivotal role in cardiovascular diagnostics. Our analysis shows the feasibility and applicability of such instrument for all types of CA. We could not only differentiate between different layers of scars, but we were also able to identify the presence of fibrosis channels among the different scar zones. None of the data derived from the ADAS 3D software seemed to be related to cardiac events in the follow-up, but this might be imputable to the restricted number of patients enrolled in the study.


Assuntos
Amiloidose , Cardiomiopatias , Cicatriz , Imageamento por Ressonância Magnética , Humanos , Masculino , Projetos Piloto , Feminino , Cardiomiopatias/diagnóstico por imagem , Amiloidose/diagnóstico por imagem , Amiloidose/complicações , Idoso , Cicatriz/diagnóstico por imagem , Estudos Retrospectivos , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Software
4.
Medicina (Kaunas) ; 60(1)2023 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-38256331

RESUMO

A cardiac lesion detected at ultrasonography might turn out to be a normal structure, a benign tumor or rarely a malignancy, and lesion characterization is very important to appropriately manage the lesion itself. The exact relationship of the mass with coronary arteries and the knowledge of possible concomitant coronary artery disease are necessary preoperative information. Moreover, the increasingly performed coronary CT angiography to evaluate non-invasively coronary artery disease leads to a rising number of incidental findings. Therefore, CT and MRI are frequently performed imaging modalities when echocardiography is deemed insufficient to evaluate a lesion. A brief comprehensive overview about diagnostic radiological imaging and the clinical background of cardiac masses and pseudomasses is reported.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Angiografia Coronária
5.
Radiol Med ; 125(11): 1024-1039, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32930945

RESUMO

Computed tomography coronary angiography (CTCA) has become a cornerstone in the diagnostic process of the heart disease. Although the cardiac imaging with interventional procedures is responsible for approximately 40% of the cumulative effective dose in medical imaging, a relevant radiation dose reduction over the last decade was obtained, with the beginning of the sub-mSv era in CTCA. The main technical basis to obtain a radiation dose reduction in CTCA is the use of a low tube voltage, the adoption of a prospective electrocardiogram-triggering spiral protocol and the application of the tube current modulation with the iterative reconstruction technique. Nevertheless, CTCA examinations are characterized by a wide range of radiation doses between different radiology departments. Moreover, the dose exposure in CTCA is extremely important because the benefit-risk calculus in comparison with other modalities also depends on it. Finally, because anatomical evaluation not adequately predicts the hemodynamic relevance of coronary stenosis, a low radiation dose in routine CTCA would allow the greatest use of the myocardial CT perfusion, fractional flow reserve-CT, dual-energy CT and artificial intelligence, to shift focus from morphological assessment to a comprehensive morphological and functional evaluation of the stenosis. Therefore, the aim of this work is to summarize the correct use of the technical basis in order that CTCA becomes an established examination for assessment of the coronary artery disease with low radiation dose.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/prevenção & controle , Fatores Etários , Algoritmos , Inteligência Artificial , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/instrumentação , Circulação Coronária , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores Sexuais , Fatores de Tempo
6.
Radiol Med ; 125(4): 365-373, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32239472

RESUMO

AIM: To subjectively and objectively evaluate the feasibility and diagnostic reliability of a low-dose, long-pitch dual-source chest CT protocol on third-generation dual-source CT (DSCT) with spectral shaping at 100Sn kVp for COVID-19 patients. MATERIALS AND METHODS: Patients with COVID-19 and positive swab-test undergoing to a chest CT on third-generation DSCT were included. The imaging protocol included a dual-energy acquisition (HD-DECT, 90/150Sn kVp) and fast, low-dose, long-pitch CT, dual-source scan at 100Sn kVp (LDCT). Subjective (Likert Scales) and objective (signal-to-noise and contrast-to-noise ratios, SNR and CNR) analyses were performed; radiation dose and acquisition times were recorded. Nonparametric tests were used. RESULTS: The median radiation dose was lower for LDCT than HD-DECT (Effective dose, ED: 0.28 mSv vs. 3.28 mSv, p = 0.016). LDCT had median acquisition time of 0.62 s (vs 2.02 s, p = 0.016). SNR and CNR were significantly different in several thoracic structures between HD-DECT and LDCT, with exception of lung parenchyma. Qualitative analysis demonstrated significant reduction in motion artifacts (p = 0.031) with comparable diagnostic reliability between HD-DECT and LDCT. CONCLUSIONS: Ultra-low-dose, dual-source, fast CT protocol provides highly diagnostic images for COVID-19 with potential for reduction in dose and motion artifacts.


Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , COVID-19 , Protocolos Clínicos , Estudos de Viabilidade , Humanos , Pandemias , Doses de Radiação , SARS-CoV-2
7.
Radiol Med ; 125(2): 117-127, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31686317

RESUMO

PURPOSE: To compare measured radiation dose (MD), estimated radiation dose (ED) and image quality in coronary computed tomography between turbo-flash (TFP) and retrospective protocol (RP) and correlate MD with size-specific dose estimates (SSDE). MATERIALS AND METHODS: In this prospective study, we selected 68 patients (mean age, 59.2 ± 9.7 years) undergoing 192 × 2 dual-source CT (SOMATOM Force, Siemens) to rule out coronary artery disease. Thirty-one underwent TFP and 37 RP. To evaluate in vivo MD, thermoluminescent dosimeters were placed, superficially, at thyroid and heart level, left breast areola and left hemi-thorax. MD in each site, and ED parameters, such as volume CT dose index (CTDIvol), SSDE, dose length product (DLP), effective dose (E), were compared between two protocols with a t test. Image quality was compared between two protocols. Inter-observer agreement was evaluated with a kappa coefficient (k). In each protocol, MD was correlated with SSDE using a Pearson coefficient (r). RESULTS: Comparing TFP and RP, MD at thyroid (1.43 vs. 2.58 mGy; p = 0.0408), heart (3.58 vs. 28.72 mGy; p < 0.0001), left breast areola (3.00 vs. 24.21 mGy; p < 0.0001) and left hemi-thorax (2.68 vs. 24.03 mGy; p < 0.0001), CTDIvol, SSDE, DLP and E were significantly lower. Differences in image quality were not statistically significant. Inter-observer agreement was good (k = 0.796) in TFP and very good (k = 0.817) in RP. MD and SSDE excellently correlated with TFP (r = 0.9298, p < 0.0001) and RP (r = 0.9753, p < 0.0001). CONCLUSIONS: With TFP, MD, CTDIvol, SSDE, DLP and E were significantly lower, than with RP. Image quality was similar between two protocols. MD correlated excellently with SSDE in each protocol.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doses de Radiação , Meios de Contraste , Feminino , Humanos , Iopamidol , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Dosimetria Termoluminescente
8.
Radiol Med ; 124(3): 184-190, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30478814

RESUMO

PURPOSE: To compare radiation dose and image quality of lower extremity computed tomography angiography (CTA) between cranio-caudal acquisition with single-source CT (SSCT) and flash caudo-cranial acquisition with dual-source CT (DSCT). MATERIALS AND METHODS: In this prospective study, 60 patients were randomly assigned to Group A (control) or Group B (experimental) to undergo lower extremity CTA for peripheral obliterative arterial disease. Group A received protocol 1 (P1) with SSCT cranio-caudal acquisition. Group B received protocol (P2) with DSCT flash caudo-cranial acquisition. Intravascular attenuation (IVA), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image noise were compared. Two radiologists assessed the image quality. Computed tomography volume dose index (CTDIvol) and dose-length product (DLP) were also compared. RESULTS: IVA with P2 was higher than with P1 (586.8 ± 140.3 vs. 496.1 ± 129.3 HU, p = 0.011), as was SNR (33.0 ± 11.3 vs. 27.4 ± 12.3; p = 0.042), CNR (30.1 ± 13.3 vs. 24.2 ± 10.3; p = 0.029) and image quality score of small arteries below the knee (3.8 ± 0.2 vs. 3.1 ± 0.2; p = 0.001). Radiation dose was significantly lower in P2 than in P1 with CTDIvol reduction of 40.9% (1.3 ± 0.1 vs. 2.2 ± 0.3 mGy; p = 0.006) and DLP reduction of 42.8% (148.7 ± 21.9 vs 260.2 ± 59.1 mGy * cm; p = 0.018). CONCLUSION: Lower extremity CTA with DSCT flash caudo-cranial acquisition allows lower radiation dose with higher IVA, SNR, CNR and better image quality for small arteries below the knee than SSCT cranio-caudal acquisition.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doses de Radiação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído , Método Simples-Cego , Adulto Jovem
9.
Radiol Med ; 124(12): 1238-1252, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31630332

RESUMO

Cardiovascular computer tomography (CT) in pediatric congenital heart disease (CHD) patients is often challenging. This might be due to limited patient cooperation, the high heart rate, the complexity and variety of diseases and the need for radiation dose minimization. The recent developments in CT technology with the introduction of the third-generation dual-source (DS) dual-energy (DE) CT scanners well suited to respond to these challenges. DSCT is characterized by high-pitch, long anatomic coverage and a more flexible electrocardiogram-synchronized scan. DE provides additional clinical information about vascular structures, myocardial and lung perfusion and allows artifacts reduction. These advances have increased clinical indications and modified CT protocol for pediatric CHD patients. In our hospital, DSCT with DE technology has rapidly become an important imaging technique for both pre- and postoperative management of pediatric patients with CHDs. The aim of this article is to describe the state-of-the-art in DSCT protocol with DE technology in pediatric CHD patients, providing some case examples of our experience over an 18-month period.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Artefatos , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Filtração/instrumentação , Frequência Cardíaca , Humanos , Lactente , Recém-Nascido , Movimentos dos Órgãos , Doses de Radiação , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/instrumentação , Respiração , Tomografia Computadorizada por Raios X/instrumentação
10.
Radiol Med ; 123(8): 563-571, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29569217

RESUMO

INTRODUCTION: We describe the use of time-resolved imaging of contrast kinetics (TRICKS) sequence in the diagnosis of Peripheral Vascular Anomalies. In case of suspected vascular malformations time-resolved MR angiography might add important information for therapeutic decisions and follow-up. OBJECTIVE: The objective of our study was to assess the usefulness and diagnostic performance of time-resolved imaging of contrast kinetics sequence in the evaluation of peripheral vascular anomalies. SUBJECTS AND METHODS: Sixty-six patients (23 pediatric, 43 adult; mean age 26) affected by upper or lower limb vascular anomalies and studied using time-resolved imaging of contrast kinetics sequence were prospectively evaluated. All studies were performed on a 1.5-T whole-body MR system. Two independent readers tried to categorized the suspected vascular anomalies in pre-contrast and post-contrast MR sequences and assessed the overall TRICKS image quality. In 11 patients, the diagnostic performance comparability between TRICKS sequence and digital subtraction angiography was evaluated. RESULTS: On the basis of time-resolved imaging of contrast kinetics, 31 of the vascular anomalies were classified as high-flow vascular malformations, 29 as low-flow vascular lesions and 6 as hemangiomas. There was no significant difference in image quality evaluation and vascular anomaly classification between the two observers. The vascular anomalies characteristics provided by moderate, good or excellent quality TRICKS images were confirmed by digital subtraction angiography. CONCLUSION: Time-resolved imaging of contrast kinetics sequence let the radiologist to acquire useful temporal information to correctly evaluate vascular anomalies components, adding more data to those provided by conventional MR sequences, especially in case of arteriovenous malformation. Therefore, both in pediatric and adult population, TRICKS could be used as an additional initial diagnostic tool to rightly classify these lesions and evaluate if a treatment is needed and which.


Assuntos
Malformações Arteriovenosas/diagnóstico por imagem , Extremidades/irrigação sanguínea , Extremidades/diagnóstico por imagem , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Angiografia Digital , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Br J Radiol ; 96(1148): 20221026, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37183830

RESUMO

OBJECTIVE: To investigate the feasibility of an ultra-low radiation dose and contrast volume protocol using third-generation dual-source (DS) CT for transcatheter aortic valve implantation (TAVI) planning with coronary artery disease (CAD) assessment, coronary artery calcium score (CACS) and aortic valve calcium score (AVCS) quantification and to evaluate their relationship with TAVI outcome. METHODS: In this retrospective study were selected 203 patients (131 males, 79.4 ± 5.4 years) underwent to TAVI and at 30- and 90-day follow-up. All patients had performed a third-generation 2 × 192-slices DSCT. The CT protocol included a non-contrast and a contrast high-pitch aortic acquisition for TAVI planning and CAD assessment. Semi-qualitative and quantitative image analysis were performed; the performance in CAD assessment was compared with ICA; the relationship between AVCS and CACS and paravalvular aortic regurgitation (PAR) and major cardiovascular events (MACEs) were evaluated. Mean radiation dose were calculated. Non-parametric tests were used. RESULTS: Semi-qualitative image analysis was good. Contrast enhancement >500 Hounsfield unit (HU) and contrast-to-noise ratio <20 were obtained in all segments. The diagnostic accuracy in CAD was 89.0%. AVCS was significantly higher in patients with 30-day severe PAR. AVCS and CACS were higher in patients with 90-day MACE complications, respectively, 1904.5 ± 621.3 HU (p < 0.0001) and 769.2 ± 365.5 HU (p < 0.0230). Mean radiation dose was 2.8 ± 0.3 mSv. CONCLUSION: A TAVI planning ultra-low radiation dose and contrast volume protocol using third-generation DSCT provides highly diagnostic images with CAD assessment, AVCS and CACS quantification and these latter were related with TAVI outcomes. ADVANCES IN KNOWLEDGE: The proposed protocol using third-generation 2 × 192-slices DSCT allows with an ultra-low radiation dose and contrast volume the TAVI planning and the coronary artery assessment.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Doença da Artéria Coronariana , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estudos Retrospectivos , Cálcio , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS