Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 213
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 25(7): 879-887, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876123

RESUMO

BACKGROUND: Artificial intelligence (AI) systems can potentially aid the diagnostic pathway of prostate cancer by alleviating the increasing workload, preventing overdiagnosis, and reducing the dependence on experienced radiologists. We aimed to investigate the performance of AI systems at detecting clinically significant prostate cancer on MRI in comparison with radiologists using the Prostate Imaging-Reporting and Data System version 2.1 (PI-RADS 2.1) and the standard of care in multidisciplinary routine practice at scale. METHODS: In this international, paired, non-inferiority, confirmatory study, we trained and externally validated an AI system (developed within an international consortium) for detecting Gleason grade group 2 or greater cancers using a retrospective cohort of 10 207 MRI examinations from 9129 patients. Of these examinations, 9207 cases from three centres (11 sites) based in the Netherlands were used for training and tuning, and 1000 cases from four centres (12 sites) based in the Netherlands and Norway were used for testing. In parallel, we facilitated a multireader, multicase observer study with 62 radiologists (45 centres in 20 countries; median 7 [IQR 5-10] years of experience in reading prostate MRI) using PI-RADS (2.1) on 400 paired MRI examinations from the testing cohort. Primary endpoints were the sensitivity, specificity, and the area under the receiver operating characteristic curve (AUROC) of the AI system in comparison with that of all readers using PI-RADS (2.1) and in comparison with that of the historical radiology readings made during multidisciplinary routine practice (ie, the standard of care with the aid of patient history and peer consultation). Histopathology and at least 3 years (median 5 [IQR 4-6] years) of follow-up were used to establish the reference standard. The statistical analysis plan was prespecified with a primary hypothesis of non-inferiority (considering a margin of 0·05) and a secondary hypothesis of superiority towards the AI system, if non-inferiority was confirmed. This study was registered at ClinicalTrials.gov, NCT05489341. FINDINGS: Of the 10 207 examinations included from Jan 1, 2012, through Dec 31, 2021, 2440 cases had histologically confirmed Gleason grade group 2 or greater prostate cancer. In the subset of 400 testing cases in which the AI system was compared with the radiologists participating in the reader study, the AI system showed a statistically superior and non-inferior AUROC of 0·91 (95% CI 0·87-0·94; p<0·0001), in comparison to the pool of 62 radiologists with an AUROC of 0·86 (0·83-0·89), with a lower boundary of the two-sided 95% Wald CI for the difference in AUROC of 0·02. At the mean PI-RADS 3 or greater operating point of all readers, the AI system detected 6·8% more cases with Gleason grade group 2 or greater cancers at the same specificity (57·7%, 95% CI 51·6-63·3), or 50·4% fewer false-positive results and 20·0% fewer cases with Gleason grade group 1 cancers at the same sensitivity (89·4%, 95% CI 85·3-92·9). In all 1000 testing cases where the AI system was compared with the radiology readings made during multidisciplinary practice, non-inferiority was not confirmed, as the AI system showed lower specificity (68·9% [95% CI 65·3-72·4] vs 69·0% [65·5-72·5]) at the same sensitivity (96·1%, 94·0-98·2) as the PI-RADS 3 or greater operating point. The lower boundary of the two-sided 95% Wald CI for the difference in specificity (-0·04) was greater than the non-inferiority margin (-0·05) and a p value below the significance threshold was reached (p<0·001). INTERPRETATION: An AI system was superior to radiologists using PI-RADS (2.1), on average, at detecting clinically significant prostate cancer and comparable to the standard of care. Such a system shows the potential to be a supportive tool within a primary diagnostic setting, with several associated benefits for patients and radiologists. Prospective validation is needed to test clinical applicability of this system. FUNDING: Health~Holland and EU Horizon 2020.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Neoplasias da Próstata , Radiologistas , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Gradação de Tumores , Países Baixos , Curva ROC
2.
J Magn Reson Imaging ; 2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-37982353

RESUMO

The increasing incidence of prostate cancer cases worldwide has led to a tremendous demand for multiparametric MRI (mpMRI). In order to relieve the pressure on healthcare, reducing mpMRI scan time is necessary. This review focuses on recent techniques proposed for faster mpMRI acquisition, specifically shortening T2W and DWI sequences while adhering to the PI-RADS (Prostate Imaging Reporting and Data System) guidelines. Speeding up techniques in the reviewed studies rely on more efficient sampling of data, ranging from the acquisition of fewer averages or b-values to adjustment of the pulse sequence. Novel acquisition methods based on undersampling techniques are often followed by suitable reconstruction methods typically incorporating synthetic priori information. These reconstruction methods often use artificial intelligence for various tasks such as denoising, artifact correction, improvement of image quality, and in the case of DWI, for the generation of synthetic high b-value images or apparent diffusion coefficient maps. Reduction of mpMRI scan time is possible, but it is crucial to maintain diagnostic quality, confirmed through radiological evaluation, to integrate the proposed methods into the standard mpMRI protocol. Additionally, before clinical integration, prospective studies are recommended to validate undersampling techniques to avoid potentially inaccurate results demonstrated by retrospective analysis. This review provides an overview of recently proposed techniques, discussing their implementation, advantages, disadvantages, and diagnostic performance according to PI-RADS guidelines compared to conventional methods. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 3.

3.
Muscle Nerve ; 68(4): 432-438, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37497843

RESUMO

INTRODUCTION/AIMS: Ultrasound imaging of muscle tissue conventionally results in two-dimensional sampling of tissue. For heterogeneously affected muscles, a sampling error using two-dimensional (2D) ultrasound can therefore be expected. In this study, we aimed to quantify and extend ultrasound imaging findings in neuromuscular disorders by using three-dimensional quantitative muscle ultrasound (3D QMUS). METHODS: Patients with facioscapulohumeral dystrophy (n = 31) and myotonic dystrophy type 1 (n = 16) were included in this study. After physical examination, including Medical Research Council (MRC) scores, the tibialis anterior muscle was scanned with automated ultrasound. QMUS parameters were calculated over 15 cm of the length of the tibialis anterior muscle and were compared with a healthy reference data set. RESULTS: With 3D QMUS local deviations from the healthy reference could be detected. Significant Pearson correlations (P < .01) between MRC score and QMUS parameters in male patients (n = 23) included the mean echo intensity (EI) (0.684), the standard deviation of EI (0.737), and the residual attenuation (0.841). In 91% of all patients, mean EI deviated by more than 1 standard deviation from the healthy reference. In general, the proportion of muscle tissue with a Z score >1 was about 50%. DISCUSSION: In addition to mean EI, multiple QMUS parameters reported in this study are potential biomarkers for pathology. Besides a moderate correlation of mean EI with muscle weakness, two other parameters showed strong correlations: standard deviation of EI and residual attenuation. Local detection of abnormalities makes 3D QMUS a promising method that can be used in research and potentially for clinical evaluation.


Assuntos
Distrofia Muscular Facioescapuloumeral , Distrofia Miotônica , Humanos , Masculino , Distrofia Miotônica/diagnóstico por imagem , Distrofia Muscular Facioescapuloumeral/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Força Muscular/fisiologia , Ultrassonografia/métodos
4.
BMC Anesthesiol ; 23(1): 238, 2023 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-37452279

RESUMO

BACKGROUND: Conflicting data exist regarding the effects of deep neuromuscular blockade (NMB) on abdominal dimensions during laparoscopic procedures. We performed a clinical study to establish the influence of moderate and deep neuromuscular blockade (NMB) on the abdominal working space, measured by Magnetic Resonance Imaging (MRI), during laparoscopic donor nephrectomy with standard pressure (12 mmHg) pneumoperitoneum under sevoflurane anaesthesia. METHODS: Ten patients were intraoperatively scanned three times in the lateral decubitus position, with pneumoperitoneum maintained by a mobile insufflator. The first scan without NMB (T1) was followed by scans with moderate (T2) and deep NMB (T3). The skin-sacral promontory (S-SP) distance was measured, and 3D pneumoperitoneum volumes were reconstructed. RESULTS: The mean difference in the S-SP distance was -0.32 cm between T2 and T3 (95% CI -1.06 - 0.42 cm; p = 0.344) and + 2.1 cm between T1 and T2 (95% CI 0.81 - 3.39 cm; p = 0.006). The mean differences in pneumoperitoneum volume were 166 mL between T2 and T3 (95% CI, 5 - 327 mL; p = 0.044) and 108 mL between T1 and T2 (95% CI, -273 - 488 mL; p = 0.525). The pneumoperitoneum volume showed high inter-individual variability and no increase in three patients with a high volume at T1. CONCLUSIONS: During laparoscopic surgery in the lateral decubitus position with standard pressure under sevoflurane anaesthesia, deep NMB did not increase the S-SP distance compared to moderate NMB. Moderate NMB increased the S-SP distance by a mean of 2.1 cm (15.2%) compared with no NMB. The mean pneumoperitoneum volume increased slightly from moderate to deep NMB, with high inter-individual variability. TRIAL REGISTRATION: Clinicaltrials.gov ID: NCT03287388.


Assuntos
Laparoscopia , Bloqueio Neuromuscular , Pneumoperitônio , Humanos , Bloqueio Neuromuscular/métodos , Sevoflurano , Laparoscopia/métodos , Abdome
5.
Eur J Nucl Med Mol Imaging ; 49(13): 4705-4715, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35829749

RESUMO

PURPOSE: Transarterial radioembolization (TARE) is a treatment for liver tumours based on injection of radioactive microspheres in the hepatic arterial system. It is crucial to achieve a maximum tumour dose for an optimal treatment response, while minimizing healthy liver dose to prevent toxicity. There is, however, no intraprocedural feedback on the dose distribution, as nuclear imaging can only be performed after treatment. As holmium-166 (166Ho) microspheres can be quantified with MRI, we investigate the feasibility and safety of performing 166Ho TARE within an MRI scanner and explore the potential of intraprocedural MRI-based dosimetry. METHODS: Six patients were treated with 166Ho TARE in a hybrid operating room. Per injection position, a microcatheter was placed under angiography guidance, after which patients were transported to an adjacent 3-T MRI system. After MRI confirmation of unchanged catheter location, 166Ho microspheres were injected in four fractions, consisting of 10%, 30%, 30% and 30% of the planned activity, alternated with holmium-sensitive MRI acquisition to assess the microsphere distribution. After the procedures, MRI-based dose maps were calculated from each intraprocedural image series using a dedicated dosimetry software package for 166Ho TARE. RESULTS: Administration of 166Ho microspheres within the MRI scanner was feasible in 9/11 (82%) injection positions. Intraprocedural holmium-sensitive MRI allowed for tumour dosimetry in 18/19 (95%) of treated tumours. Two CTCAE grade 3-4 toxicities were observed, and no adverse events were attributed to treatment in the MRI. Towards the last fraction, 4/18 tumours exhibited signs of saturation, while in 14/18 tumours, the microsphere uptake patterns did not deviate from the linear trend. CONCLUSION: This study demonstrated feasibility and preliminary safety of a first in-human application of TARE within a clinical MRI system. Intraprocedural MRI-based dosimetry enabled dynamic insight in the microsphere distribution during TARE. This proof of concept yields unique possibilities to better understand microsphere distribution in vivo and to potentially optimize treatment efficacy through treatment personalization. REGISTRATION: Clinicaltrials.gov, identifier NCT04269499, registered on February 13, 2020 (retrospectively registered).


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/métodos , Hólmio/uso terapêutico , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética , Microesferas , Radioisótopos de Ítrio
6.
J Magn Reson Imaging ; 56(5): 1322-1342, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35420239

RESUMO

BACKGROUND: MRI guidance of arterial endovascular interventions could be beneficial as it does not require radiation exposure, allows intrinsic blood-tissue contrast, and enables three-dimensional and functional imaging, however, clinical applications are still limited. PURPOSE: To review the current state of MRI-guided arterial endovascular interventions and to identify the most commonly reported challenges. STUDY TYPE: Systematic review. POPULATION: Pubmed, Embase, Web of Science, and The Cochrane Library were systematically searched to find relevant articles. The search strategy combined synonyms for vascular pathology, endovascular therapy, and real-time MRI guidance. FIELD STRENGTH/SEQUENCE: No field strength or sequence restrictions were applied. ASSESSMENT: Two reviewers independently identified and reviewed the original articles and extracted relevant data. STATISTICAL TESTS: Results of the included original articles are reported. RESULTS: A total of 24,809 studies were identified for screening. Eighty-eight studies were assessed for eligibility, after which data were extracted from 43 articles (6 phantom, 33 animal, and 4 human studies). Reported technical success rates for animal and human studies ranged between 42% to 100%, and the average complication rate was 5.8% (animal studies) and 8.8% (human studies). Main identified challenges were related to spatial and temporal resolution as well as safety, design, and scarcity of current MRI-compatible endovascular devices. DATA CONCLUSION: MRI guidance of endovascular arterial interventions seems feasible, however, included articles included mostly small single-center case series. Several hurdles remain to be overcome before larger trials can be undertaken. Main areas of research should focus on adequate imaging protocols with integrated tracking of dedicated endovascular devices.


Assuntos
Artérias , Imageamento por Ressonância Magnética , Animais , Humanos
7.
Curr Oncol Rep ; 24(11): 1433-1441, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35670993

RESUMO

PURPOSE OF REVIEW: Minimal invasive procedures, including targeted biopsy (TB) and focal therapy (FT), are increasingly used in diagnosis and treatment of localized prostate cancer. Here, we review the current role of these procedures, from a perspective of an interventional radiologist. RECENT FINDINGS: TB is an established part of current guidelines for diagnosis of PCa. Several modalities of FT are gaining prevalence in recent years, as a tissue-preserving alternative for definitive treatment of localized PCa. FT is currently at early research stages, offered to selected patients in clinical trials settings. TB and FT are minimally invasive procedures used by multidisciplinary teams for diagnosis and treatment of localized PCa.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/terapia , Biópsia , Radiologistas , Procedimentos Cirúrgicos Minimamente Invasivos
8.
Clin Anat ; 35(6): 701-710, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35383381

RESUMO

A comprehensive lymphatic system is indispensable for a well-functioning body; it is integral to the immune system and is also interrelated with the digestive system and fluid homeostasis. The main difficulty in examining the lymphatic system is its fine-meshed structure. This remains a challenge, leaving patients with uninterpreted symptoms and a dearth of potential therapies. We review the history of the lymphatic system up to the present with the aim of improving current knowledge. Several findings described throughout history have made fundamental contributions to elucidating the lymphatic system. The first contributions were made by the ancient Egyptians and the ancient Greeks. Vesalius obtained new insights by dissecting corpses. Thereafter, Ruysch (1638-1731) gained an understanding of lymphatic flow. In 1784, Mascagni published his illustration of the whole lymphatic network. The introduction of radiological lymphography revolutionized knowledge of the lymphatic system. Pedal lymphangiography was first described by Monteiro (1931) and Kinmonth (1952). Lymphoscintigraphy (nuclear medicine), magnetic resonance imaging, and near-infrared fluorescence lymphography further improved visualization of the lymphatic system. The innovative dynamic contrast-enhanced magnetic resonance lymphangiography (DCMRL) transformed understanding of the central lymphatic system, enabling central lymphatic flow disorders in patients to be diagnosed and even allowing for therapeutic planning. From the perspective of the history of lymph visualization, DCMRL has ample potential for identifying specific causes of debilitating symptoms in patients with central lymphatic system abnormalities and even allows for therapeutic planning.


Assuntos
Doenças Linfáticas , Vasos Linfáticos , Meios de Contraste , Humanos , Sistema Linfático/diagnóstico por imagem , Vasos Linfáticos/diagnóstico por imagem , Linfografia/métodos , Imageamento por Ressonância Magnética/métodos
9.
J Clin Monit Comput ; 36(1): 141-145, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33398546

RESUMO

Thermodilution cardiac output monitoring, using a thermistor-tipped intravascular catheter, is used in critically ill patients to guide hemodynamic therapy. Often, these patients also need magnetic resonance imaging (MRI) for diagnostic or prognostic reasons. As thermodilution catheters contain metal, they are considered MRI-unsafe and advised to be removed prior to investigation. However, removal and replacement of the catheter carries risks of bleeding, perforation and infection. This research is an in vitro safety assessment of the PiCCO™ thermodilution catheter during 3 T Magnetic Resonance Imaging (3T-MRI).  In a 3T-MRI environment, three different PiCCO™ catheter sizes were investigated in an agarose-gel, tissue mimicking phantom. Two temperature probes measured radiofrequency-induced heating; one at the catheter tip and one at a reference point. Magnetically induced catheter dislocation was assessed by visual observation as well as by analysis of the tomographic images. For all tested catheters, the highest measured temperature increase was 0.2 °C at the center of the bore and 0.3 °C under "worst-case" setting for the tested MRI pulse sequences. No magnetically induced catheter displacements were observed. Under the tested circumstances, no heating or dislocation of the PiCCO™ catheter was observed in a tissue mimicking phantom during 3T-MRI. Leaving the catheter in the critically ill patient during MRI investigation might pose a lower risk of complications than catheter removal and replacement.


Assuntos
Estado Terminal , Termodiluição , Débito Cardíaco , Catéteres , Humanos , Imageamento por Ressonância Magnética , Termodiluição/métodos
10.
Int J Cancer ; 149(3): 635-645, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33739453

RESUMO

Inadequate margins continue to occur frequently in patients who undergo surgical resection of a tumor, suggesting that current intraoperative methods are not sufficiently reliable in determining the margin status. This clinical demand has inspired the development of many novel imaging techniques that could help surgeons with intraoperative margin assessment. This systematic review provides an overview of novel imaging techniques for intraoperative margin assessment in surgical oncology, and reports on their technical properties, feasibility in clinical practice and diagnostic accuracy. PubMed, Embase, Web of Science and the Cochrane library were systematically searched (2013-2018) for studies reporting on imaging techniques for intraoperative margin assessment. Patient and study characteristics, technical properties, feasibility characteristics and diagnostic accuracy were extracted. This systematic review identified 134 studies that investigated and developed 16 groups of techniques for intraoperative margin assessment: fluorescence, advanced microscopy, ultrasound, specimen radiography, optical coherence tomography, magnetic resonance imaging, elastic scattering spectroscopy, bio-impedance, X-ray computed tomography, mass spectrometry, Raman spectroscopy, nuclear medicine imaging, terahertz imaging, photoacoustic imaging, hyperspectral imaging and pH measurement. Most studies were in early developmental stages (IDEAL 1 or 2a, n = 98); high-quality stage 2b and 3 studies were rare. None of the techniques was found to be clearly superior in demonstrating high feasibility as well as high diagnostic accuracy. In conclusion, the field of imaging techniques for intraoperative margin assessment is highly evolving. This review provides a unique overview of the opportunities and limitations of the currently available imaging techniques.


Assuntos
Imageamento por Ressonância Magnética/métodos , Margens de Excisão , Neoplasias/patologia , Neoplasias/cirurgia , Oncologia Cirúrgica , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia/métodos , Humanos , Neoplasias/diagnóstico por imagem , Prognóstico
11.
Muscle Nerve ; 64(2): 199-205, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34033127

RESUMO

INTRODUCTION/AIMS: Quantitative muscle ultrasound offers biomarkers that aid in the diagnosis, detection, and follow-up of neuromuscular disorders. At present, quantitative muscle ultrasound methods are 2D and are often operator and device dependent. The aim of this study was to combine an existing device independent method with an automated ultrasound machine and perform 3D quantitative muscle ultrasound, providing new normative data of healthy controls. METHODS: In total, 123 healthy volunteers were included. After physical examination, 3D ultrasound scans of the tibialis anterior muscle were acquired using an automated ultrasound scanner. Image postprocessing was performed to obtain calibrated echo intensity values based on a phantom reference. RESULTS: Tibialis anterior muscle volumes of 61.2 ± 24.1 mL and 53.7 ± 22.7 mL were scanned in males and females, respectively. Echo intensity correlated with gender**, age**, fat fraction*, histogram kurtosis**, skewness* and standard deviation** (*P < .05, **P < .01). Outcome measures did not differ significantly for different acquisition presets. The 3D quantitative muscle ultrasound revealed the non-uniformity of echo intensity values over the length of the tibialis anterior muscle. DISCUSSION: Our method extended 2D measurements and confirmed previous findings. Our method and reported normative data of (potential) biomarkers can be used to study neuromuscular disorders.


Assuntos
Imageamento Tridimensional , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Ultrassonografia , Adulto , Biomarcadores/análise , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Ultrassonografia/métodos
12.
World J Urol ; 39(3): 637-649, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394091

RESUMO

The use of multiparametric MRI has been hastened under expanding, novel indications for its use in the diagnostic and management pathway of men with prostate cancer. This has helped drive a large body of the literature describing its evolving role over the last decade. Despite this, prostate cancer remains the only solid organ malignancy routinely diagnosed with random sampling. Herein, we summarize the components of multiparametric MRI and interpretation, and present a critical review of the current literature supporting is use in prostate cancer detection, risk stratification, and management.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/diagnóstico por imagem , Humanos , Masculino
13.
Radiology ; 296(1): 76-84, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32315265

RESUMO

Background Prostate MRI is used widely in clinical care for guiding tissue sampling, active surveillance, and staging. The Prostate Imaging Reporting and Data System (PI-RADS) helps provide a standardized probabilistic approach for identifying clinically significant prostate cancer. Despite widespread use, the variability in performance of prostate MRI across practices remains unknown. Purpose To estimate the positive predictive value (PPV) of PI-RADS for the detection of high-grade prostate cancer across imaging centers. Materials and Methods This retrospective cross-sectional study was compliant with the HIPAA. Twenty-six centers with members in the Society of Abdominal Radiology Prostate Cancer Disease-focused Panel submitted data from men with suspected or biopsy-proven untreated prostate cancer. MRI scans were obtained between January 2015 and April 2018. This was followed with targeted biopsy. Only men with at least one MRI lesion assigned a PI-RADS score of 2-5 were included. Outcome was prostate cancer with Gleason score (GS) greater than or equal to 3+4 (International Society of Urological Pathology grade group ≥2). A mixed-model logistic regression with institution and individuals as random effects was used to estimate overall PPVs. The variability of observed PPV of PI-RADS across imaging centers was described by using the median and interquartile range. Results The authors evaluated 3449 men (mean age, 65 years ± 8 [standard deviation]) with 5082 lesions. Biopsy results showed 1698 cancers with GS greater than or equal to 3+4 (International Society of Urological Pathology grade group ≥2) in 2082 men. Across all centers, the estimated PPV was 35% (95% confidence interval [CI]: 27%, 43%) for a PI-RADS score greater than or equal to 3 and 49% (95% CI: 40%, 58%) for a PI-RADS score greater than or equal to 4. The interquartile ranges of PPV at these same PI-RADS score thresholds were 27%-44% and 27%-48%, respectively. Conclusion The positive predictive value of the Prostate Imaging and Reporting Data System was low and varied widely across centers. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Milot in this issue.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Sistemas de Informação em Radiologia , Idoso , Estudos Transversais , Humanos , Masculino , Valor Preditivo dos Testes , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sociedades Médicas
14.
Eur J Nucl Med Mol Imaging ; 47(8): 1864-1870, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31768601

RESUMO

PURPOSE: Detection of residual or recurrent vital renal tumor on follow-up (FU) cross-sectional imaging after ablative therapy is challenging. The specific and high expression levels of carbonic anhydrase IX (CAIX) in clear cell renal cell carcinoma (ccRCC) makes it a suitable target for imaging using radiolabeled anti-CAIX antibody girentuximab. The objective of this study was to evaluate the feasibility of targeted FU imaging 1 month after cryoablation of ccRCC using single photon emission computed tomography (SPECT) after 111In-labeled girentuximab administration. METHODS: In this prospective study 16 patients underwent 111In-girentuximab-SPECT before MR-guided renal cryoablation between February 2015 and September 2018. In case of tumor targeting 111In-girentuximab-SPECT was repeated 1 month following MR-guided cryoablation. Presence of residual or recurrent vital tumor was assessed on contrast-enhanced cross-sectional imaging during further FU. The standard FU imaging protocol consisted of MRI/CT scans at 1, 3, 6, 12, and 18 months and annually thereafter. RESULTS: A total of 10 (63%) patients showed positive tumor targeting on 111In-girentuximab-SPECT before cryoablation and 9 ( 56%) were eligible to undergo FU SPECT. Of the 9 111In-girentuximab-SPECT FU scans, 8 (89%) were considered negative. One (11%) scan showed uptake suggestive for residual vital tumor. Six months after treatment, FU CT showed contrast enhancement suggestive for residual/recurrent disease in the ablated zone at the site of the 111In-girentuximab uptake after treatment. During a mean FU of 21 months (range 1-33) no other cases with residual/recurrent disease were detected. CONCLUSION: FU imaging with 111In-girentuximab-SPECT is feasible after ccRCC cryoablation and may contribute to early detection of residual or recurrent disease.


Assuntos
Carcinoma de Células Renais , Criocirurgia , Neoplasias Renais , Anticorpos Monoclonais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Seguimentos , Humanos , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Recidiva Local de Neoplasia/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único
15.
Eur Radiol ; 30(6): 3356-3362, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32060713

RESUMO

OBJECTIVES: Automated ultrasound of the breast has the advantage to have the whole breast scanned by technicians. Consequently, feedback to the radiologist about concurrent focal abnormalities (e.g., palpable lesions) is lost. To enable marking of patient- or physician-reported focal abnormalities, we aimed to develop skin markers that can be used without disturbing the interpretability of the image. METHODS: Disk-shaped markers were casted out of silicone. In this IRB-approved prospective study, 16 patients were included with a mean age of 57 (39-85). In all patients, the same volume was imaged twice using an automated breast ultrasound system, once with and once without a marker in place. Nine radiologists from two medical centers filled scoring forms regarding image quality, image interpretation, and confidence in providing a diagnosis based on the images. RESULTS: Marker adhesion was sufficient for automated scanning. Observer scores showed a significant shift in scores from excellent to good regarding diagnostic yield/image quality (χ2, 15.99, p < 0.01), and image noise (χ2, 21.20, p < 0.01) due to marker presence. In 93% of cases, the median score of observers "agree" with the statement that marker-induced noise did not influence image interpretability. Marker presence did not interfere with confidence in diagnosis (χ2, 6.00, p = 0.20). CONCLUSION: Inexpensive, easy producible skin markers can be used for accurate lesion marking in automated ultrasound examinations of the breast while image interpretability is preserved. Any marker-induced noise and decreased image quality did not affect confidence in providing a diagnosis. KEY POINTS: • The use of a skin marker enables the reporting radiologist to identify a location which a patient is concerned about. • The developed skin marker can be used for accurate breast lesion marking in ultrasound examinations.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Imageamento Tridimensional/métodos , Silicones , Pele , Ultrassonografia Mamária/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Equipamentos e Provisões , Feminino , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Sensibilidade e Especificidade
16.
Eur Radiol ; 30(2): 934-942, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31471752

RESUMO

OBJECTIVES: To evaluate the accuracy and clinical integrability of a comprehensive simulation tool to plan and predict radiofrequency ablation (RFA) zones in liver tumors. METHODS: Forty-five patients with 51 malignant hepatic lesions of different origins were included in a prospective multicenter trial. Prior to CT-guided RFA, all patients underwent multiphase CT which included acquisitions for the assessment of liver perfusion. These data were used to generate a 3D model of the liver. The intra-procedural position of the RFA probe was determined by CT and semi-automatically registered to the 3D model. Size and shape of the simulated ablation zones were compared with those of the thermal ablation zones segmented in contrast-enhanced CT images 1 month after RFA; procedure time was compared with a historical control group. RESULTS: Simulated and segmented ablation zone volumes showed a significant correlation (ρ = 0.59, p < 0.0001) and no significant bias (Wilcoxon's Z = 0.68, p = 0.25). Representative measures of ablation zone comparison were as follows: average surface deviation (absolute average error, AAE) with 3.4 ± 1.7 mm, Dice similarity coefficient 0.62 ± 0.14, sensitivity 0.70 ± 0.21, and positive predictive value 0.66 ± 0. There was a moderate positive correlation between AAE and duration of the ablation (∆t; r = 0.37, p = 0.008). After adjustments for inter-individual differences in ∆t, liver perfusion, and prior transarterial chemoembolization procedures, ∆t was an independent predictor of AAE (ß = 0.03 mm/min, p = 0.01). Compared with a historical control group, the simulation added 3.5 ± 1.9 min to the procedure. CONCLUSION: The validated simulation tool showed acceptable speed and accuracy in predicting the size and shape of hepatic RFA ablation zones. Further randomized controlled trials are needed to evaluate to what extent this tool might improve patient outcomes. KEY POINTS: • More reliable, patient-specific intra-procedural estimation of the induced RFA ablation zones in the liver may lead to better planning of the safety margins around tumors. • Dedicated real-time simulation software to predict RFA-induced ablation zones in patients with liver malignancies has shown acceptable agreement with the follow-up results in a first prospective multicenter trial suggesting a randomized controlled clinical trial to evaluate potential outcome benefit for patients.


Assuntos
Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/cirurgia , Adolescente , Adulto , Idoso , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/métodos , Simulação por Computador , Feminino , Humanos , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Planejamento de Assistência ao Paciente , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
17.
J Vasc Interv Radiol ; 31(1): 35-41, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31735483

RESUMO

PURPOSE: To evaluate safety, quality of life (QoL), and local cancer control after focal salvage MR imaging-guided cryoablation in patients with local recurrence of prostate cancer (PCa) after radiotherapy. MATERIALS AND METHODS: A retrospective, single-center study was performed in 62 patients with radiorecurrent PCa who underwent MR imaging-guided cryoablation since May 2011 with a follow-up ≥12 months in December 2017. Rates and descriptions of adverse events were reported. Ablation complications were classified according to the Clavien and SIR systems. Validated questionnaires were used to observe functional outcomes and QoL before therapy and 6 and 12 months after therapy. Cancer control was defined as no biochemical failure according to Phoenix criteria and no other clinical evidence for local or metastatic disease. RESULTS: All procedures were technically feasible. The number of complications requiring major therapy (Clavien grade 3b/4 or SIR grade D/E/F) was low (2 [3.2%] and 1 [1.6%], respectively). After 12 months, the International Consultation of Incontinence Questionnaire-Short Form (P < .001) and 5-item International Index of Erectile Function (P = .001) scores became significantly worse, indicating increased symptoms of incontinence and diminished erectile function, without compromising QoL. Six patients developed metastases within 6 months. After 12 months, 36 patients (63%) were disease-free. CONCLUSIONS: Focal salvage MR imaging-guided cryoablation is safe and is associated with a high technical success rate, preservation of QoL, and local PCa control. This treatment can be a reasonable alternative to salvage radical prostatectomy in properly selected patients with low morbidity and preservation of QoL; however, longer follow-up is needed.


Assuntos
Criocirurgia , Imagem por Ressonância Magnética Intervencionista , Recidiva Local de Neoplasia , Neoplasias da Próstata/radioterapia , Neoplasias da Próstata/cirurgia , Terapia de Salvação , Idoso , Tomada de Decisão Clínica , Criocirurgia/efeitos adversos , Intervalo Livre de Doença , Humanos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Seleção de Pacientes , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Qualidade de Vida , Estudos Retrospectivos , Terapia de Salvação/efeitos adversos , Fatores de Tempo
18.
Clin Anat ; 33(1): 25-33, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31087400

RESUMO

We aim to provide an overview of the various digital three-dimensional visualizations used for learning anatomy and to assess whether these improve medical students' understanding of anatomy compared to traditional learning methods. Furthermore, we evaluate the attitudes of the users of three-dimensional visualizations. We included articles that compared advanced newer three-dimensional anatomy visualization methods (i.e., virtual reality, augmented reality, and computer-based three-dimensional visualizations) to traditional methods that have been used for a long time (i.e., cadaver and textbooks) with regard to users' understanding of anatomy. Of the 1,148 articles identified, 21 articles reported data on the effectiveness of using three-dimensional visualization methods compared to two-dimensional methods. Twelve articles found that three-dimensional visualization is a significantly more effective learning method compared to traditional methods, whereas nine articles did not find that three-dimensional visualization was a significantly more effective method. In general, based on these articles, medical students prefer to use three-dimensional visualizations to learn anatomy. In most of the articles, using three-dimensional visualization was shown to be a more effective method to gain anatomical knowledge compared to traditional methods. Besides that, students are motivated and interested in using these new visualization methods for learning anatomical structures. Clin. Anat. 32:25-33, 2019. © 2019 Wiley Periodicals, Inc.


Assuntos
Anatomia/educação , Simulação por Computador , Educação Médica/métodos , Imageamento Tridimensional , Modelos Anatômicos , Treinamento por Simulação/métodos , Humanos
19.
NMR Biomed ; 32(1): e4025, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30431192

RESUMO

In the surgical treatment of vulvar squamous-cell carcinoma (VSCC), tumor-free margins of 8 mm or more are considered adequate. However, limited perioperative information on the tumor-free margins other than the surgeon's own estimation is available. The purpose of this study was therefore to investigate the feasibility of ex vivo MRI in localizing VSCC and to assess the surgical tumor-free margins in fresh radical local excision (RLE) specimens to guide the surgeon during resections. Nine patients with biopsy-proven VSCC scheduled for RLE were prospectively included. Intact fresh specimens were scanned using a 7 T preclinical MR-scanner. Whole mount H&E-stained slides were obtained every 3 mm and correlated with ex vivo MRI. A pathologist annotated VSCC and minimal tumor-free margins (3 o'clock, 9 o'clock, basal) on the digitalized histological slides. An observer with knowledge of histology (the non-blinded annotation) and a radiologist blinded to histology (the blinded annotation) separately performed annotation of the same features on ex vivo MRI. Linear correlation and agreement of the ex vivo MRI measurements with histology were assessed. Diagnostic performance for VSCC localization and identification of margins less than 8 mm was expressed as positive and negative predictive values (PPV, NPV). In 153 matched ex vivo MRI slices, the observer correctly identified 79/91 margins as less than 8 mm (PPV 87%) and 110/124 margins as 8 mm or greater (NPV 89%). The radiologist correctly annotated absence of VSCC in 73/81 (NPV 90%) and presence in 65/72 (PPV 90%) slices. Sixty-four of 90 margins were correctly identified as less than 8 mm (PPV 71%) and 83/102 margins as 8 mm or greater (NPV 81%). Both non-blinded and blinded annotations were linearly correlated and demonstrated good agreement with histology. Accurate localization of VSCC and measurements of the surgical tumor-free margins in fresh RLE specimens using ex vivo MRI seems feasible. High diagnostic performance in VSCC localization and identification of margins less than 8 mm suggest ex vivo MRI to be clinically applicable.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Imageamento por Ressonância Magnética , Margens de Excisão , Neoplasias Vulvares/diagnóstico por imagem , Neoplasias Vulvares/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Sensibilidade e Especificidade
20.
BJU Int ; 124(5): 775-784, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31237388

RESUMO

OBJECTIVE: To determine the proportion of men avoiding biopsy because of negative multiparametric magnetic resonance imaging (mpMRI) findings in a prostate MRI expert centre, and to assess the number of clinically significant prostate cancers (csPCa) detected during follow-up. PATIENTS AND METHODS: Retrospective study of 4259 consecutive men having mpMRI of the prostate between January 2012 and December 2017, with either a history of previous negative transrectal ultrasonography-guided biopsy or biopsy naïve. Patients underwent mpMRI in a referral centre. Lesions were classified according to Prostate Imaging Reporting And Data System (PI-RADS) versions 1 and 2. Negative mpMRI was defined as an index lesion PI-RADS ≤2. Follow-up until 13 October 2018 was collected by searching the Dutch Pathology Registry (PALGA). Gleason score ≥3 + 4 was considered csPCa. Kaplan-Meier analysis and univariable logistic regression models were used in the cohort of patients with negative mpMRI and follow-up. RESULTS: Overall, in 53.6% (2281/4259) of patients had a lesion classified as PI-RADS ≤2. In 320 patients with PI-RADS 1 or 2, follow-up mpMRI was obtained after a median (interquartile range) of 57 (41-63) months. In those patients, csPCa diagnosis-free survival (DFS) was 99.6% after 3 years. Univariable logistic regression analysis revealed age as a predictor for csPCa during follow-up (P < 0.05). In biopsied patients, csPCa was detected in 15.8% (19/120), 43.2% (228/528) and 74.5% (483/648) with PI-RADS 3, 4 and 5, respectively. CONCLUSION: More than half of patients having mpMRI of the prostate avoided biopsy. In those patients, csPCa DFS was 99.6% after 3 years.


Assuntos
Biópsia/estatística & dados numéricos , Imageamento por Ressonância Magnética Multiparamétrica , Próstata , Neoplasias da Próstata , Idoso , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/mortalidade , Neoplasias da Próstata/patologia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA