Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 93(7): 1367-1373, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30536569

RESUMO

OBJECTIVE: This study sought to assess the potential benefits of the transradial approach (TRA) as an alternative vascular access to the classical contralateral femoral approach for transcatheter aortic valve replacement (TAVR). BACKGROUND: Vascular and bleeding complications in TAVR have gradually decreased owing to operator experience and downsizing of the delivery system. However, about 1/4 of vascular access site complications are related to the transfemoral (TF) secondary access. METHODS: We compared the outcomes at 30 days according to VARC-2 after TAVR of a prospective cohort of 217 consecutive patients undergoing right or left TRA as the second vascular access (TRA-TF TAVR) and a retrospective cohort of 194 consecutive patients undergoing TF approach as a second vascular access (TF-TF TAVR). RESULTS: Baseline clinical characteristics and risk scores were well matched in both groups. Procedural success rate was 99.7%. Fluoro time was significantly lower in the TF-TF TAVR group (16.9 ± 7.2 vs. 19.1 ± 7.8 min, P = 0.003); however, there was no significant difference in x-ray exposure, procedure time or amount of contrast used. In the TRA-TF TAVR group, there were no complications related to the TRA access and there were less vascular and bleeding complications (18.0% vs. 9.7%, P = 0.014; 17.0% vs. 9.2%, P = 0.026, respectively), although blood transfusion requirement or hospitalization duration stay were similar in both groups. CONCLUSIONS: TRA approach as alternative secondary vascular access in TAVR is safe and feasible and is associated with a significant decrease in vascular and bleeding complications. Further, large-scale studies are warranted to confirm the potential benefit of this approach.


Assuntos
Estenose da Valva Aórtica/cirurgia , Cateterismo Periférico , Artéria Femoral , Hospitais com Alto Volume de Atendimentos , Artéria Radial , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Tempo de Internação , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/terapia , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Exposição à Radiação , Radiografia Intervencionista , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Int J Cardiovasc Imaging ; 35(9): 1721-1731, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31250161

RESUMO

To compare planned and achieved device position in patients undergoing left atrial appendage occlusion (LAAO). It is unclear how devices used for LAAO position themselves compared to what is planned. All patients undergoing LAAO at our institution had pre- and post-procedural multi detector-row computed tomography (MDCT) at 3 months (N = 52). Using dedicated software, both datasets were fused to superimpose the left atria in all planes. The effective device position was traced on the post-procedural MDCT and then imported in the pre-procedural dataset to allow comparisons. Planned and effective landing zones were compared with respect to size, location and orientation. The device's final position was in a significantly larger landing zone than planned (452 ± 174 vs. 351 ± 112 mm2 for effective and planned landing zones, respectively, paired t-test: p < 0.0001), resulting in significantly less-than-intended area oversizing (41 ± 31 vs. 12 ± 28%, p < 0.0001). In terms of device orientation, there was a difference of 19.7° between the planned and effective landing zones (p < 0.0001). The Amplatzer device had a shallower-than-planned position in 70% of cases, whereas the Watchman device had a deeper-than-planned position in 75% of cases (p = 0.04). Incomplete occlusion was found in 17 patients (33%). In a multivariable model, oversizing at the effective landing zone was the only MDCT independent predictor of incomplete occlusion (OR: 0.96 per 1% increment, 95% CI 0.95-0.98, p = 0.009). MDCT fusion showed that LAAO device position and orientation are different than planned, and this is associated with incomplete occlusion of the LAA.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Imageamento Tridimensional/métodos , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Terapia Assistida por Computador/instrumentação , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Tomada de Decisão Clínica , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudo de Prova de Conceito , Estudos Retrospectivos , Software , Resultado do Tratamento
4.
Rev Esp Cardiol (Engl Ed) ; 66(8): 629-35, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24776331

RESUMO

INTRODUCTION AND OBJECTIVES: There is little data available for Spain on the outcomes of surgical treatment for severe tricuspid regurgitation. The aim of this study was to analyze clinical and echocardiographic outcomes in a series of patients who received surgical treatment for severe tricuspid regurgitation and to compare outcomes according to the operative approach to valve repair or replacement. METHODS: Retrospective study in 119 consecutive patients with severe tricuspid regurgitation undergoing valve surgery between April 1996 and February 2010. RESULTS: A total of 61 ringless and 23 ring annuloplasties were performed and 11 bioprostheses and 24 mechanical prostheses were implanted. Perioperative mortality was 18.5% and was associated with age and cardiopulmonary bypass time. During clinical follow-up (median, 41 [interquartile range, 24-89] months), 2 reoperations were required in the ring annuloplasty and mechanical prosthesis groups; prosthetic thrombosis was diagnosed in 4 patients in the latter group. Total mortality after follow-up was 29.9% and was associated with age>70 years and extracorporeal circulation time. The emergence of new severe tricuspid regurgitation was associated with age and ringless annuloplasty (P=.04). CONCLUSIONS: Ringless repair was significantly associated with recurrence of severe tricuspid regurgitation. The use of mechanical prostheses was associated with a high rate of thrombosis. No significant differences in perioperative or total mortality were found between the different methods used for repair or valve replacement.


Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Tricúspide/cirurgia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA