Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Biomech Eng ; 143(12)2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34318314

RESUMO

Rupture risk assessment of abdominal aortic aneurysms (AAAs) by means of quantifying wall stress is a common biomechanical strategy. However, the clinical translation of this approach has been greatly limited due to the complexity associated with the computational tools required for its implementation. Thus, being able to estimate wall stress using nonbiomechanical markers that can be quantified as a direct outcome of clinical image segmentation would be advantageous in improving the potential implementation of said strategy. In the present work, we investigated the use of geometric indices to predict patient-specific AAA wall stress by means of a novel neural network (NN) modeling approach. We conducted a retrospective review of existing clinical images of two patient groups: 98 asymptomatic and 50 symptomatic AAAs. The images were subject to a protocol consisting of image segmentation, processing, volume meshing, finite element modeling, and geometry quantification, from which 53 geometric indices and the spatially averaged wall stress (SAWS) were calculated. SAWS estimated from finite element analysis was considered the gold standard for the predictions. We developed feed-forward NN models composed of an input layer, two dense layers, and an output layer using Keras, a deep learning library in python. The NN models were trained, tested, and validated independently for both AAA groups using all geometric indices, as well as a reduced set of indices resulting from a variable reduction procedure. We compared the performance of the NN models with two standard machine learning algorithms (MARS: multivariate adaptive regression splines and GAM: generalized additive model) and a linear regression model (GLM: generalized linear model). With the reduced sets of indices, the NN-based approach exhibited the highest mean goodness-of-fit (for the symptomatic group 0.71 and for the asymptomatic group 0.79) and lowest mean relative error (17% for both groups). In contrast, MARS yielded a mean goodness-of-fit of 0.59 for the symptomatic group and 0.77 for the asymptomatic group, with relative errors of 17% for the symptomatic group and 22% for the asymptomatic group. GAM had a mean goodness-of-fit of 0.70 for the symptomatic group and 0.80 for the asymptomatic group, with relative errors of 16% for the symptomatic group and 20% for the asymptomatic group. GLM did not perform as well as the other algorithms, with a mean goodness-of-fit of 0.53 for the symptomatic group and 0.70 for the asymptomatic group, with relative errors of 19% for the symptomatic group and 23% for the asymptomatic group. Nevertheless, the NN models required a reduced set of 15 and 13 geometric indices to predict SAWS for the symptomatic and asymptomatic AAA groups, respectively. This was in contrast to the reduced set of nine and eight geometric indices required to predict SAWS with the MARS and GAM algorithms for each AAA group, respectively. The use of NN modeling represents a promising alternative methodology for the estimation of AAA wall stress using geometric indices as surrogates, in lieu of finite element modeling. The performance metrics of NN models are expected to improve with significantly larger group sizes, given the suitability of NN modeling for "big data" applications.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/complicações , Análise de Elementos Finitos , Humanos , Modelos Cardiovasculares , Redes Neurais de Computação , Estudos Retrospectivos , Medição de Risco/métodos , Estresse Mecânico
2.
J Biomech Eng ; 143(3)2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33269788

RESUMO

Myocardial bridging (MB) and coronary atherosclerotic stenosis can impair coronary blood flow and may cause myocardial ischemia or even heart attack. It remains unclear how MB and stenosis are similar or different regarding their impacts on coronary hemodynamics. The purpose of this study was to compare the hemodynamic effects of coronary stenosis and MB using experimental and computational fluid dynamics (CFD) approaches. For CFD modeling, three MB patients with different levels of lumen obstruction, mild, moderate, and severe were selected. Patient-specific left anterior descending (LAD) coronary artery models were reconstructed from biplane angiograms. For each MB patient, the virtually healthy and stenotic models were also simulated for comparison. In addition, an in vitro flow-loop was developed, and the pressure drop was measured for comparison. The CFD simulations results demonstrated that the difference between MB and stenosis increased with increasing MB/stenosis severity and flowrate. Experimental results showed that increasing the MB length (by 140%) only had significant impact on the pressure drop in the severe MB (39% increase at the exercise), but increasing the stenosis length dramatically increased the pressure drop in both moderate and severe stenoses at all flow rates (31% and 93% increase at the exercise, respectively). Both CFD and experimental results confirmed that the MB had a higher maximum and a lower mean pressure drop in comparison with the stenosis, regardless of the degree of lumen obstruction. A better understanding of MB and atherosclerotic stenosis may improve the therapeutic strategies in coronary disease patients and prevent acute coronary syndromes.


Assuntos
Ponte Miocárdica
3.
J Biomech Eng ; 143(5)2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33493273

RESUMO

Biomechanical characterization of abdominal aortic aneurysms (AAAs) has become commonplace in rupture risk assessment studies. However, its translation to the clinic has been greatly limited due to the complexity associated with its tools and their implementation. The unattainability of patient-specific tissue properties leads to the use of generalized population-averaged material models in finite element analyses, which adds a degree of uncertainty to the wall mechanics quantification. In addition, computational fluid dynamics modeling of AAA typically lacks the patient-specific inflow and outflow boundary conditions that should be obtained by nonstandard of care clinical imaging. An alternative approach for analyzing AAA flow and sac volume changes is to conduct in vitro experiments in a controlled laboratory environment. In this study, we designed, built, and characterized quantitatively a benchtop flow loop using a deformable AAA silicone phantom representative of a patient-specific geometry. The impedance modules, which are essential components of the flow loop, were fine-tuned to ensure typical intraluminal pressure conditions within the AAA sac. The phantom was imaged with a magnetic resonance imaging (MRI) scanner to acquire time-resolved images of the moving wall and the velocity field inside the sac. Temporal AAA sac volume changes lead to a corresponding variation in compliance throughout the cardiac cycle. The primary outcome of this work was the design optimization of the impedance elements, the quantitative characterization of the resistive and capacitive attributes of a compliant AAA phantom, and the exemplary use of MRI for flow visualization and quantification of the deformed AAA geometry.


Assuntos
Aneurisma da Aorta Abdominal
4.
J Biomech Eng ; 142(6)2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633169

RESUMO

In this work, we provide a quantitative assessment of the biomechanical and geometric features that characterize abdominal aortic aneurysm (AAA) models generated from 19 Asian and 19 Caucasian diameter-matched AAA patients. 3D patient-specific finite element models were generated and used to compute peak wall stress (PWS), 99th percentile wall stress (99th WS), and spatially averaged wall stress (AWS) for each AAA. In addition, 51 global geometric indices were calculated, which quantify the wall thickness, shape, and curvature of each AAA. The indices were correlated with 99th WS (the only biomechanical metric that exhibited significant association with geometric indices) using Spearman's correlation and subsequently with multivariate linear regression using backward elimination. For the Asian AAA group, 99th WS was highly correlated (R2 = 0.77) with three geometric indices, namely tortuosity, intraluminal thrombus volume, and area-averaged Gaussian curvature. Similarly, 99th WS in the Caucasian AAA group was highly correlated (R2 = 0.87) with six geometric indices, namely maximum AAA diameter, distal neck diameter, diameter-height ratio, minimum wall thickness variance, mode of the wall thickness variance, and area-averaged Gaussian curvature. Significant differences were found between the two groups for ten geometric indices; however, no differences were found for any of their respective biomechanical attributes. Assuming maximum AAA diameter as the most predictive metric for wall stress was found to be imprecise: 24% and 28% accuracy for the Asian and Caucasian groups, respectively. This investigation reveals that geometric indices other than maximum AAA diameter can serve as predictors of wall stress, and potentially for assessment of aneurysm rupture risk, in the Asian and Caucasian AAA populations.


Assuntos
Aneurisma da Aorta Abdominal , Análise de Elementos Finitos , Fenômenos Biomecânicos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares
5.
J Biomech Eng ; 141(9)2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31116359

RESUMO

Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles and account for a significant portion of human ventricular mass. The role of trabeculae carneae in diastolic and systolic functions of the left ventricle (LV) is not well understood. Thus, the objective of this study was to investigate the functional role of trabeculae carneae in the LV. Finite element (FE) analyses of ventricular functions were conducted for three different models of human LV derived from high-resolution magnetic resonance imaging (MRI). The first model comprised trabeculae carneae and papillary muscles, while the second model had papillary muscles and partial trabeculae carneae, and the third model had a smooth endocardial surface. We customized these patient-specific models with myofiber architecture generated with a rule-based algorithm, diastolic material parameters of Fung strain energy function derived from biaxial tests and adjusted with the empirical Klotz relationship, and myocardial contractility constants optimized for average normal ejection fraction (EF) of the human LV. Results showed that the partial trabeculae cutting model had enlarged end-diastolic volume (EDV), reduced wall stiffness, and even increased end-systolic function, indicating that the absence of trabeculae carneae increased the compliance of the LV during diastole, while maintaining systolic function.

6.
Ann Vasc Surg ; 44: 190-196, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28546046

RESUMO

BACKGROUND: Currently, the risk of abdominal aortic aneurysm (AAA) rupture is determined using the maximum diameter (Dmax) of the aorta. We sought in this study to identify a set of computed tomography (CT)-based geometric parameters that would better predict the risk of rupture than Dmax. METHODS: We obtained CT scans from 180 patients (90 ruptured AAA and 90 elective AAA repair) and then used automated software to calculate 1- , 2- , and 3-dimensional geometric parameters for each AAA. Linear regression was used to identify univariate correlates of membership in the rupture group. We then used stepwise backward elimination to generate a logistic regression model for prediction of rupture. RESULTS: Linear regression identified 40 correlates of rupture. Following stepwise backward elimination, we developed a multivariate logistic regression model containing 15 geometric parameters, including Dmax. This model was compared with a model containing Dmax alone. The multivariate model correctly classified 98% of all cases, whereas the Dmax-only model correctly classified 72% of cases. Receiver operating characteristic analysis showed that the multivariate model had an area under the curve of 0.995, as compared with 0.770 for the Dmax-only model. This difference was highly significant (P < 0.0001). CONCLUSIONS: This study demonstrates that a multivariable model using geometric factors entirely measurable from CT scanning can be a better predictor of AAA rupture than maximum diameter alone.


Assuntos
Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/etiologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Área Sob a Curva , Chicago , Humanos , Modelos Lineares , Modelos Logísticos , Análise Multivariada , Pennsylvania , Valor Preditivo dos Testes , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Software
7.
J Biomech Eng ; 139(1)2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27636678

RESUMO

An abdominal aortic aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta of at least 1.5 times its normal diameter. Although the criterion of maximum diameter is still used in clinical practice to decide on a timely intervention, numerical studies have demonstrated the importance of other geometric factors. However, the major drawback of numerical studies is that they must be validated experimentally before clinical implementation. This work presents a new methodology to verify wall stress predicted from the numerical studies against the experimental testing. To this end, four AAA phantoms were manufactured using vacuum casting. The geometry of each phantom was subject to microcomputed tomography (µCT) scanning at zero and three other intraluminal pressures: 80, 100, and 120 mm Hg. A zero-pressure geometry algorithm was used to calculate the wall stress in the phantom, while the numerical wall stress was calculated with a finite-element analysis (FEA) solver based on the actual zero-pressure geometry subjected to 80, 100, and 120 mm Hg intraluminal pressure loading. Results demonstrate the moderate accuracy of this methodology with small relative differences in the average wall stress (1.14%). Additionally, the contribution of geometric factors to the wall stress distribution was statistically analyzed for the four phantoms. The results showed a significant correlation between wall thickness and mean curvature (MC) with wall stress.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Resistência ao Cisalhamento , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Humanos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estresse Mecânico , Tomografia Computadorizada por Raios X/instrumentação
8.
J Biomech Eng ; 139(8)2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28538996

RESUMO

The maximum diameter (MD) criterion is the most important factor when predicting risk of rupture of abdominal aortic aneurysms (AAAs). An elevated wall stress has also been linked to a high risk of aneurysm rupture, yet is an uncommon clinical practice to compute AAA wall stress. The purpose of this study is to assess whether other characteristics of the AAA geometry are statistically correlated with wall stress. Using in-house segmentation and meshing algorithms, 30 patient-specific AAA models were generated for finite element analysis (FEA). These models were subsequently used to estimate wall stress and maximum diameter and to evaluate the spatial distributions of wall thickness, cross-sectional diameter, mean curvature, and Gaussian curvature. Data analysis consisted of statistical correlations of the aforementioned geometry metrics with wall stress for the 30 AAA inner and outer wall surfaces. In addition, a linear regression analysis was performed with all the AAA wall surfaces to quantify the relationship of the geometric indices with wall stress. These analyses indicated that while all the geometry metrics have statistically significant correlations with wall stress, the local mean curvature (LMC) exhibits the highest average Pearson's correlation coefficient for both inner and outer wall surfaces. The linear regression analysis revealed coefficients of determination for the outer and inner wall surfaces of 0.712 and 0.516, respectively, with LMC having the largest effect on the linear regression equation with wall stress. This work underscores the importance of evaluating AAA mean wall curvature as a potential surrogate for wall stress.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Estresse Mecânico , Análise de Elementos Finitos , Humanos , Propriedades de Superfície
9.
J Biomech Eng ; 138(10)2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27538124

RESUMO

In this work, we present a novel method for the derivation of the unloaded geometry of an abdominal aortic aneurysm (AAA) from a pressurized geometry in turn obtained by 3D reconstruction of computed tomography (CT) images. The approach was experimentally validated with an aneurysm phantom loaded with gauge pressures of 80, 120, and 140 mm Hg. The unloaded phantom geometries estimated from these pressurized states were compared to the actual unloaded phantom geometry, resulting in mean nodal surface distances of up to 3.9% of the maximum aneurysm diameter. An in-silico verification was also performed using a patient-specific AAA mesh, resulting in maximum nodal surface distances of 8 µm after running the algorithm for eight iterations. The methodology was then applied to 12 patient-specific AAA for which their corresponding unloaded geometries were generated in 5-8 iterations. The wall mechanics resulting from finite element analysis of the pressurized (CT image-based) and unloaded geometries were compared to quantify the relative importance of using an unloaded geometry for AAA biomechanics. The pressurized AAA models underestimate peak wall stress (quantified by the first principal stress component) on average by 15% compared to the unloaded AAA models. The validation and application of the method, readily compatible with any finite element solver, underscores the importance of generating the unloaded AAA volume mesh prior to using wall stress as a biomechanical marker for rupture risk assessment.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Pressão Sanguínea , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento
10.
FASEB J ; 27(8): 3017-29, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23616566

RESUMO

Endothelial adhesion is necessary for the hematogenous dissemination of tumor cells. However, the metastatic breast tumor cell MDA-MB-231 does not bind to the endothelium under physiological flow conditions, suggesting alternate mechanisms of adhesion. Since monocytes are highly represented in the tumor microenvironment, and also bind to endothelium during inflammation, we hypothesized that the monocytes assist in the arrest of MDA-MB-231 on the endothelium. Using in vitro models of the dynamic shear environment of the vasculature, we show that TNF-α-activated THP1/primary human monocytes and MDA-MB-231 cells form stable aggregates, and that the monocytes in these aggregates mediate the adhesion of otherwise nonadherent MDA-MB-231 cells to inflamed endothelium under flow (55±2.4 vs. 1.7±0.82 at a shear stress of 0.5 dyn/cm(2), P<0.01). We also show that the hydrodynamic forces determine the size and orientation of aggregates adhered to the endothelium, and strongly favor the attachment of small aggregates with tumor cells downstream of flow (74-86% doublets at 0.5-2 dyn/cm(2), P<0.01). The 5-fold up-regulation of ICAM-1 on TNF-α-activated MDA-MB-231 cells through the Nf-κB pathway was found to be critical in MDA-MB-231-monocyte aggregation and endothelial adhesion. Our results demonstrate that, under inflammatory conditions, monocytes may serve to disseminate tumor cells through circulation, and the tumor-monocyte-endothelial axis may represent a new therapeutic target to reduce cancer metastasis.


Assuntos
Endotélio Vascular/metabolismo , Molécula 1 de Adesão Intercelular/metabolismo , Monócitos/metabolismo , NF-kappa B/metabolismo , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Adesão Celular , Agregação Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Células Cultivadas , Simulação por Computador , Endotélio Vascular/patologia , Humanos , Molécula 1 de Adesão Intercelular/genética , Cinética , NF-kappa B/genética , Metástase Neoplásica , Transdução de Sinais/efeitos dos fármacos , Estresse Mecânico , Fator de Necrose Tumoral alfa/farmacologia , Regulação para Cima/efeitos dos fármacos
11.
J Biomech Eng ; 136(12): 121010, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25322073

RESUMO

To quantify the transport and adhesion of drug particles in a complex vascular environment, computational fluid particle dynamics (CFPD) simulations of blood flow and drug particulate were conducted in three different geometries representing the human lung vasculature for steady and pulsatile flow conditions. A fully developed flow profile was assumed as the inlet velocity, and a lumped mathematical model was used for the calculation of the outlet pressure boundary condition. A receptor-ligand model was used to simulate the particle binding probability. The results indicate that bigger particles have lower deposition fraction due to less chance of successful binding. Realistic unsteady flow significantly accelerates the binding activity over a wide range of particle sizes and also improves the particle deposition fraction in bifurcation regions when comparing with steady flow condition. Furthermore, surface imperfections and geometrical complexity coupled with the pulsatility effect can enhance fluid mixing and accordingly particle binding efficiency. The particle binding density at bifurcation regions increases with generation order and drug carriers are washed away faster in steady flow. Thus, when studying drug delivery mechanism in vitro and in vivo, it is important to take into account blood flow pulsatility in realistic geometry. Moreover, tissues close to bifurcations are more susceptible to deterioration due to higher uptake.


Assuntos
Hidrodinâmica , Pulmão/irrigação sanguínea , Modelos Biológicos , Artéria Pulmonar/metabolismo , Adulto , Transporte Biológico , Humanos , Tamanho da Partícula , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiologia , Fluxo Pulsátil , Tomografia Computadorizada por Raios X
12.
J Biomech Eng ; 136(1): 014502, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24190650

RESUMO

The goal of this work is to develop a framework for manufacturing nonuniform wall thickness replicas of abdominal aortic aneurysms (AAAs). The methodology was based on the use of computed tomography (CT) images for virtual modeling, additive manufacturing for the initial physical replica, and a vacuum casting process and range of polyurethane resins for the final rubberlike phantom. The average wall thickness of the resulting AAA phantom was compared with the average thickness of the corresponding patient-specific virtual model, obtaining an average dimensional mismatch of 180 µm (11.14%). The material characterization of the artery was determined from uniaxial tensile tests as various combinations of polyurethane resins were chosen due to their similarity with ex vivo AAA mechanical behavior in the physiological stress configuration. The proposed methodology yields AAA phantoms with nonuniform wall thickness using a fast and low-cost process. These replicas may be used in benchtop experiments to validate deformations obtained with numerical simulations using finite element analysis, or to validate optical methods developed to image ex vivo arterial deformations during pressure-inflation testing.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Simulação por Computador , Modelos Cardiovasculares , Aneurisma da Aorta Abdominal/patologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Modelos Anatômicos , Imagens de Fantasmas , Estresse Fisiológico , Tomografia Computadorizada por Raios X
13.
J Biomech Eng ; 136(7)2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24718322

RESUMO

Skin wounds and burns compromise the body's natural barrier to bacteria and other pathogens. While many forms of wound dressings are available, polymeric films are advantageous for various reasons, ranging from the ease of application to durability. One common drawback of using polymeric films for a wound bandage is that the films tend to adhere to common inanimate objects. Patients spend hours in contact with soft and hard materials pressed against their skin, which, if the skin was dressed with a polymeric film, would inflict further wound damage upon body movement. In this work, we present a novel technique that allowed for measuring polymeric tackiness, after a long incubation period, with materials regularly encountered in a hospital or home setting, and soft fabrics. The polymers were exposed to an environment intended to simulate daily conditions and the technique is designed to perform multiple experiments simultaneously with ease. Four commercially available polymers (new-skin, no-sting skin-prep, skin shield, and Silesse) were tested as proof-of-concept to gather preliminary data for an overall assessment of wound treatment efficacy, resulting in the estimation of pull-off stress of the polymers from a specimen of porcine skin. Silesse did not reveal a measurable tackiness, no-sting skin-prep had the highest mean tackiness (13.8 kPa), while the mean tackiness between new-skin and skin shield was approximately equal (9.8 kPa vs. 10.1 kPa, respectively), p = 0.05. Future work on polymeric fluids for wound dressing applications should include tensile stress and dynamic viscosity estimations.


Assuntos
Bandagens , Teste de Materiais/métodos , Polímeros , Estresse Mecânico , Cicatrização , Adesividade , Animais , Teste de Materiais/instrumentação , Pele , Suínos
14.
J Biomech Eng ; 136(3): 031001, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24316984

RESUMO

The pathology of the human abdominal aortic aneurysm (AAA) and its relationship to the later complication of intraluminal thrombus (ILT) formation remains unclear. The hemodynamics in the diseased abdominal aorta are hypothesized to be a key contributor to the formation and growth of ILT. The objective of this investigation is to establish a reliable 3D flow visualization method with corresponding validation tests with high confidence in order to provide insight into the basic hemodynamic features for a better understanding of hemodynamics in AAA pathology and seek potential treatment for AAA diseases. A stereoscopic particle image velocity (PIV) experiment was conducted using transparent patient-specific experimental AAA models (with and without ILT) at three axial planes. Results show that before ILT formation, a 3D vortex was generated in the AAA phantom. This geometry-related vortex was not observed after the formation of ILT, indicating its possible role in the subsequent appearance of ILT in this patient. It may indicate that a longer residence time of recirculated blood flow in the aortic lumen due to this vortex caused sufficient shear-induced platelet activation to develop ILT and maintain uniform flow conditions. Additionally, two computational fluid dynamics (CFD) modeling codes (Fluent and an in-house cardiovascular CFD code) were compared with the two-dimensional, three-component velocity stereoscopic PIV data. Results showed that correlation coefficients of the out-of-plane velocity data between PIV and both CFD methods are greater than 0.85, demonstrating good quantitative agreement. The stereoscopic PIV study can be utilized as test case templates for ongoing efforts in cardiovascular CFD solver development. Likewise, it is envisaged that the patient-specific data may provide a benchmark for further studying hemodynamics of actual AAA, ILT, and their convolution effects under physiological conditions for clinical applications.


Assuntos
Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Reologia/métodos , Trombose/fisiopatologia , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/patologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Humanos , Trombose/etiologia , Trombose/patologia
15.
J Vasc Surg ; 57(2): 309-317.e2, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23265587

RESUMO

OBJECTIVE: This study aims to review retrospectively the records of patients treated with carotid artery stenting (CAS) to investigate the potential correlations between clinical variables, distal protection filter (DPF) type and characteristics, and 30-day peri-/postprocedural outcomes. METHODS: This is a multicenter, single-arm, nonrandomized retrospective study of patients who underwent filter-protected CAS in the Pittsburgh, Pennsylvania, region between July 2000 and May 2011. Analysis of peri-/postprocedural complications included myocardial infarction, transient ischemic attacks (TIA), stroke, death, and a composition of all adverse events (AEs). Filter characteristics for Accunet (Abbott Vascular, Santa Clara, Calif; n = 429 [58.8%]), Angioguard (Cordis Endovascular, Miami Lakes, Fla; n = 114 [15.6%]), FilterWire (Boston Scientific, Natick, Mass; n = 113 [15.5%]), Spider (ev3 Endovascular, Plymouth, Minn; n = 45 [6.2%]), and Emboshield (Abbott Vascular; n = 24 [3.3%]) were previously determined in vitro and were used to find correlations with CAS procedural outcomes. Both univariate and multivariate analyses were performed, as well as goodness-of-fit tests to find multivariate correlations with procedural outcomes. RESULTS: In total, 731 CAS procedures using six different DPFs were analyzed. Peri-/postprocedural AEs included 19 TIAs (2.6%), 38 strokes (5.2%), one myocardial infarction (0.1%), 19 deaths (3.6%), and a total of 61 patients with complications (8.3%). Univariate analysis for filter design characteristics showed that the composite of AE was negatively associated with both vascular resistance (P = .01) and eccentricity (P = .02) and was positively associated with porosity (P = .0007), number of pores (P = .005), and pore density (P = .001). Multivariate analysis and the goodness-of-fit test revealed that patients with a history of congestive heart failure, stroke, and TIA (each with odds ratio >1) led to a good-fit model P value of .72 for peri-/postprocedural AEs. Multivariate analysis was inconclusive for all filter design characteristics. CONCLUSIONS: The following filter design characteristics are independently significant for minimizing peri-/postprocedural AEs: higher vascular resistance, concentric in shape, greater capture efficiency, lower porosity, lower number of pores, and lower pore density. Lower porosity and smaller wall apposition were also found to be independently significant for minimization of peri-/postprocedural TIAs. This information can be used when considering the desirable design characteristics of future DPFs.).


Assuntos
Angioplastia/instrumentação , Doenças das Artérias Carótidas/terapia , Dispositivos de Proteção Embólica , Stents , Idoso , Idoso de 80 Anos ou mais , Angioplastia/efeitos adversos , Angioplastia/mortalidade , Doenças das Artérias Carótidas/complicações , Doenças das Artérias Carótidas/diagnóstico , Doenças das Artérias Carótidas/mortalidade , Doenças das Artérias Carótidas/fisiopatologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Ataque Isquêmico Transitório/etiologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/etiologia , Razão de Chances , Pennsylvania , Porosidade , Desenho de Prótese , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Fatores de Tempo , Resultado do Tratamento , Resistência Vascular
16.
J Biomech Eng ; 135(8): 81010, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23722475

RESUMO

Abdominal aortic aneurysm (AAA) is a vascular condition where the use of a biomechanics-based assessment for patient-specific risk assessment is a promising approach for clinical management of the disease. Among various factors that affect such assessment, AAA wall thickness is expected to be an important factor. However, regionally varying patient-specific wall thickness has not been incorporated as a modeling feature in AAA biomechanics. To the best our knowledge, the present work is the first to incorporate patient-specific variable wall thickness without an underlying empirical assumption on its distribution for AAA wall mechanics estimation. In this work, we present a novel method for incorporating regionally varying wall thickness (the "PSNUT" modeling strategy) in AAA finite element modeling and the application of this method to a diameter-matched cohort of 28 AAA geometries to assess differences in wall mechanics originating from the conventional assumption of a uniform wall thickness. For the latter, we used both a literature-derived population average wall thickness (1.5 mm; the "UT" strategy) as well as the spatial average of our patient-specific variable wall thickness (the "PSUT" strategy). For the three different wall thickness modeling strategies, wall mechanics were assessed by four biomechanical parameters: the spatial maxima of the first principal stress, strain, strain-energy density, and displacement. A statistical analysis was performed to address the hypothesis that the use of any uniform wall thickness model resulted in significantly different biomechanical parameters compared to a patient-specific regionally varying wall thickness model. Statistically significant differences were obtained with the UT modeling strategy compared to the PSNUT strategy for the spatial maxima of the first principal stress (p = 0.002), strain (p = 0.0005), and strain-energy density (p = 7.83 e-5) but not for displacement (p = 0.773). Likewise, significant differences were obtained comparing the PSUT modeling strategy with the PSNUT strategy for the spatial maxima of the first principal stress (p = 9.68 e-7), strain (p = 1.03 e-8), strain-energy density (p = 9.94 e-8), and displacement (p = 0.0059). No significant differences were obtained comparing the UT and PSUT strategies for the spatial maxima of the first principal stress (p = 0.285), strain (p = 0.152), strain-energy density (p = 0.222), and displacement (p = 0.0981). This work strongly recommends the use of patient-specific regionally varying wall thickness derived from the segmentation of abdominal computed tomography (CT) scans if the AAA finite element analysis is focused on estimating peak biomechanical parameters, such as stress, strain, and strain-energy density.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/patologia , Ruptura Aórtica/fisiopatologia , Fenômenos Biomecânicos , Engenharia Biomédica , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Fatores de Risco , Tomografia Computadorizada por Raios X
17.
J Biomech Eng ; 135(8): 81001, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23719760

RESUMO

Rupture risk assessment of abdominal aortic aneurysms (AAA) by means of biomechanical analysis is a viable alternative to the traditional clinical practice of using a critical diameter for recommending elective repair. However, an accurate prediction of biomechanical parameters, such as mechanical stress, strain, and shear stress, is possible if the AAA models and boundary conditions are truly patient specific. In this work, we present a complete fluid-structure interaction (FSI) framework for patient-specific AAA passive mechanics assessment that utilizes individualized inflow and outflow boundary conditions. The purpose of the study is two-fold: (1) to develop a novel semiautomated methodology that derives velocity components from phase-contrast magnetic resonance images (PC-MRI) in the infrarenal aorta and successfully apply it as an inflow boundary condition for a patient-specific fully coupled FSI analysis and (2) to apply a one-way-coupled FSI analysis and test its efficiency compared to transient computational solid stress and fully coupled FSI analyses for the estimation of AAA biomechanical parameters. For a fully coupled FSI simulation, our results indicate that an inlet velocity profile modeled with three patient-specific velocity components and a velocity profile modeled with only the axial velocity component yield nearly identical maximum principal stress (σ1), maximum principal strain (ε1), and wall shear stress (WSS) distributions. An inlet Womersley velocity profile leads to a 5% difference in peak σ1, 3% in peak ε1, and 14% in peak WSS compared to the three-component inlet velocity profile in the fully coupled FSI analysis. The peak wall stress and strain were found to be in phase with the systolic inlet flow rate, therefore indicating the necessity to capture the patient-specific hemodynamics by means of FSI modeling. The proposed one-way-coupled FSI approach showed potential for reasonably accurate biomechanical assessment with less computational effort, leading to differences in peak σ1, ε1, and WSS of 14%, 4%, and 18%, respectively, compared to the axial component inlet velocity profile in the fully coupled FSI analysis. The transient computational solid stress approach yielded significantly higher differences in these parameters and is not recommended for accurate assessment of AAA wall passive mechanics. This work demonstrates the influence of the flow dynamics resulting from patient-specific inflow boundary conditions on AAA biomechanical assessment and describes methods to evaluate it through fully coupled and one-way-coupled fluid-structure interaction analysis.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/patologia , Ruptura Aórtica/fisiopatologia , Fenômenos Biomecânicos , Engenharia Biomédica , Velocidade do Fluxo Sanguíneo , Análise de Elementos Finitos , Hemodinâmica , Humanos , Angiografia por Ressonância Magnética , Masculino , Interpretação de Imagem Radiográfica Assistida por Computador , Fatores de Risco , Tomografia Computadorizada por Raios X
18.
J Biomech Eng ; 135(2): 021016, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23445061

RESUMO

Stimulated by a recent controversy regarding pressure drops predicted in a giant aneurysm with a proximal stenosis, the present study sought to assess variability in the prediction of pressures and flow by a wide variety of research groups. In phase I, lumen geometry, flow rates, and fluid properties were specified, leaving each research group to choose their solver, discretization, and solution strategies. Variability was assessed by having each group interpolate their results onto a standardized mesh and centerline. For phase II, a physical model of the geometry was constructed, from which pressure and flow rates were measured. Groups repeated their simulations using a geometry reconstructed from a micro-computed tomography (CT) scan of the physical model with the measured flow rates and fluid properties. Phase I results from 25 groups demonstrated remarkable consistency in the pressure patterns, with the majority predicting peak systolic pressure drops within 8% of each other. Aneurysm sac flow patterns were more variable with only a few groups reporting peak systolic flow instabilities owing to their use of high temporal resolutions. Variability for phase II was comparable, and the median predicted pressure drops were within a few millimeters of mercury of the measured values but only after accounting for submillimeter errors in the reconstruction of the life-sized flow model from micro-CT. In summary, pressure can be predicted with consistency by CFD across a wide range of solvers and solution strategies, but this may not hold true for specific flow patterns or derived quantities. Future challenges are needed and should focus on hemodynamic quantities thought to be of clinical interest.


Assuntos
Aneurisma/fisiopatologia , Bioengenharia , Circulação Sanguínea , Simulação por Computador , Hidrodinâmica , Pressão , Congressos como Assunto , Humanos , Cinética , Sociedades Científicas
19.
J Endovasc Ther ; 19(2): 249-60, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22545892

RESUMO

PURPOSE: To compare the performance in vitro of 6 distal protection filters (DPFs) on the basis of filtration ability and effects on pressure gradient and vascular impedance in a flow model of the internal carotid artery (ICA). METHODS: Six DPFs (Accunet, Angioguard, FilterWire, Gore Embolic Filter, NAV6, and SpiderFX) were evaluated in a physiologically realistic flow loop. A blood analog was heated to body temperature and circulated by a pulsatile pump outputting a time-varying flow rate representative of the ICA. The ICA flow model was a highly curved tube representing a challenging site for filter deployment. The DPFs were deployed at the apex of the curved segment, and 2 sizes of microspheres (143 and 200 µm) were injected to simulate embolization. The capture efficiency, pressure gradient, normalized pressure gradient, and vascular impedance were calculated. RESULTS: The Gore filter had high capture efficiency (143 µm: 99.97%; 200 µm: 100.00%) with relatively small increases in pressure gradient (143 µm: +27%; 200 µm: +20%) and vascular impedance (143 µm: +23.4%; 200 µm: +6.1%) after particles were injected. Spider had the lowest capture efficiency (143 µm: 1.50%; 200 µm: 19.34%, p<0.0005), while NAV6 (143 µm: +916%, p<0.0005) and Accunet (200 µm: +179%, p<0.0005) yielded the largest pressure gradient increases. CONCLUSION: A bench-top flow apparatus exhibiting physiologically realistic conditions was developed by combining pulsatile flow and a body temperature blood analog. Using microspheres larger than the pore size of most of the DPFs, the device-wall apposition has an important effect on the overall filter performance and the global fluid dynamics in the flow model.


Assuntos
Artéria Carótida Interna/fisiopatologia , Estenose das Carótidas/terapia , Dispositivos de Proteção Embólica , Hemodinâmica , Pressão Sanguínea , Temperatura Corporal , Artéria Carótida Interna/patologia , Estenose das Carótidas/patologia , Estenose das Carótidas/fisiopatologia , Humanos , Bombas de Infusão , Teste de Materiais , Microesferas , Modelos Cardiovasculares , Polímeros , Desenho de Prótese , Fluxo Pulsátil , Fluxo Sanguíneo Regional , Fatores de Tempo
20.
Sci Rep ; 12(1): 99, 2022 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-34997075

RESUMO

Abdominal aortic aneurysm (AAA) formation and expansion is highly complex and multifactorial, and the improvement of animal models is an important step to enhance our understanding of AAA pathophysiology. In this study, we explore our ability to influence aneurysm growth in a topical elastase plus ß-Aminopropionitrile (BAPN) mouse model by varying elastase concentration and by altering the cross-linking capability of the tissue. To do so, we assess both chronic and acute effects of elastase concentration using volumetric ultrasound. Our results suggest that the applied elastase concentration affects initial elastin degradation, as well as long-term vessel expansion. Additionally, we assessed the effects of BAPN by (1) removing it to restore the cross-linking capability of tissue after aneurysm formation and (2) adding it to animals with stable aneurysms to interrupt cross-linking. These results demonstrate that, even after aneurysm formation, lysyl oxidase inhibition remains necessary for continued expansion. Removing BAPN reduces the aneurysm growth rate to near zero, resulting in a stable aneurysm. In contrast, adding BAPN causes a stable aneurysm to expand. Altogether, these results demonstrate the ability of elastase concentration and BAPN to modulate aneurysm growth rate and severity. The findings open several new areas of investigation in a murine model that mimics many aspects of human AAA.


Assuntos
Aminopropionitrilo , Aorta Abdominal/enzimologia , Aneurisma da Aorta Abdominal/induzido quimicamente , Elastase Pancreática , Proteína-Lisina 6-Oxidase/antagonistas & inibidores , Administração Tópica , Animais , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/enzimologia , Aneurisma da Aorta Abdominal/patologia , Dilatação Patológica , Modelos Animais de Doenças , Progressão da Doença , Feminino , Masculino , Camundongos Endogâmicos C57BL , Proteína-Lisina 6-Oxidase/metabolismo , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA