Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Electrocardiol ; 42(6): 481-6, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19631947

RESUMO

The AngelMed Guardian is an implantable medical device that records cardiac data and detects ischemic events using a standard pacemaker intracardiac lead positioned in the right ventricular apex. The Guardian has been implanted in 55 people in the United States and Brazil and is currently undergoing a Food and Drug Administration phase 2 pivotal trial in the United States. The Guardian detects acute ischemic events by analyzing ST-segment shifts. The ST-segment shifts are calculated as the difference between the ST deviation of a current 10-second electrogram window and a baseline ST deviation value. If the ST-segment shift is greater than a heart rate-dependent programmable threshold, then the device generates an emergency alert signal. Results thus far have demonstrated that (i) the intracardiac electrogram is relatively noise-free and (ii) the ST-shift technique used by the Guardian is effective for detecting acute ischemic events.


Assuntos
Diagnóstico por Computador/instrumentação , Eletrocardiografia Ambulatorial/instrumentação , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/prevenção & controle , Marca-Passo Artificial , Próteses e Implantes , Animais , Diagnóstico por Computador/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Suínos
2.
J Am Coll Cardiol ; 74(16): 2047-2055, 2019 10 22.
Artigo em Inglês | MEDLINE | ID: mdl-31623762

RESUMO

BACKGROUND: Increased pre-hospital delay during acute coronary syndrome (ACS) events contributes to worse outcome. OBJECTIVES: The purpose of this study was to assess the effectiveness of an implanted cardiac monitor with real-time alarms for abnormal ST-segment shifts to reduce pre-hospital delay during ACS events. METHODS: In the ALERTS (AngeLmed Early Recognition and Treatment of STEMI) pivotal study, subjects at high risk for recurrent ACS events (n = 907) were randomized to control (Alarms OFF) or treatment groups for 6 months, after which alarms were activated in all subjects (Alarms ON). Emergency department (ED) visits with standard-of-care cardiac test results were independently adjudicated as true- or false-positive ACS events. Alarm-to-door (A2D) and symptom-to-door (S2D) times were calculated for true-positive ACS ED visits triggered by 3 possible prompts: alarm only, alarms + symptoms, or symptoms only. RESULTS: The Alarms ON group showed reduced delays, with 55% (95% confidence interval [CI]: 46% to 63%) of ED visits for ACS events <2 h compared with 10% (95% CI: 2% to 27%) in the Alarms OFF group (p < 0.0001). Results were similar when restricted to myocardial infarction (MI) events. Median pre-hospital delay for MI was 12.7 h for Alarms OFF and 1.6 h in Alarms ON subjects (p < 0.0089). Median A2D delay was 1.4 h for asymptomatic MI. Median S2D delay for symptoms-only MI (no alarm) in Alarms ON was 4.3 h. CONCLUSIONS: Intracardiac monitoring with real-time alarms for ST-segment shift that exceeds a subject's self-normative ischemia threshold level significantly reduced the proportion of pre-hospital delays >2 h for ACS events, including asymptomatic MI, compared with symptoms-only ED visits in Alarms OFF. (AngeLmed for Early Recognition and Treatment of STEMI [ALERTS]; NCT00781118).


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/terapia , Alarmes Clínicos , Tempo para o Tratamento , Adulto , Idoso , Serviço Hospitalar de Emergência , Reações Falso-Positivas , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Estudos Prospectivos , Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Resultado do Tratamento
3.
Cardiovasc Revasc Med ; 6(1): 14-20, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16263351

RESUMO

BACKGROUND: Early identification of acute MI and prompt intervention can improve clinical outcomes. It would be valuable to identify a method that could allow the earliest possible detection of myocardial injury or ischemia. METHODS AND RESULTS: This article reports one of the first clinical investigations to examine the ability of an intracardiac right ventricular (RV) electrode to identify the early onset of myocardial ischemia/injury in a cohort of patients undergoing balloon occlusion of a coronary artery during percutaneous transluminal coronary angioplasty. The primary data set for analysis included observations from 14 patients with 17 lesions, with a matched comparison of a V6 surface lead and the RV to left upper chest, "intracardiac" lead. The intracardiac lead was sensitive in detecting myocardial injury current/ischemia. There was a 36.4+/-5.6% ST-segment shift, relative to the amplitude of the QRS complex, in the intracardiac lead at 2 min, compared with a 10.1+/-1.9% ST shift from a surface lead (P=.00011). The RV to left upper chest lead detected a >10% shift in ST segment within 2 min in 17 (100%) of 17 cases vs. 8 (47%) of 17 for a V6 surface lead. The intracardiac lead provided detection of ischemia in all three major epicardial coronary distributions. CONCLUSIONS: This study demonstrates the ability of an intracardiac (RV apex to left upper chest) lead to rapidly detect myocardial ischemia/injury during acute coronary occlusion in the setting of balloon angioplasty. The results of this study suggest that a simple implantable system resembling a ventricular pacemaker could be programmed to assist in the very early diagnosis of acute myocardial infarction.


Assuntos
Doença das Coronárias/diagnóstico , Doença das Coronárias/terapia , Vasos Coronários/fisiopatologia , Eletrocardiografia/instrumentação , Monitorização Fisiológica/métodos , Isquemia Miocárdica/diagnóstico , Análise de Variância , Angioplastia com Balão/métodos , Oclusão com Balão/efeitos adversos , Oclusão com Balão/métodos , Estudos de Coortes , Angiografia Coronária/métodos , Doença das Coronárias/fisiopatologia , Eletrocardiografia/métodos , Eletrodos , Estudos de Viabilidade , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Isquemia Miocárdica/fisiopatologia , Marca-Passo Artificial , Projetos Piloto , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Fatores de Tempo
4.
Cardiovasc Revasc Med ; 16(4): 221-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979565

RESUMO

BACKGROUND/PURPOSE: We update the pre-clinical and early clinical results using a novel endovascular approach, to perform chemical renal denervation, via peri-adventitial injection of micro-doses of dehydrated alcohol (ethanol-EtOH). METHODS/MATERIALS: A novel, three-needle delivery device (Peregrine™) was used to denervate the renal arteries of adult swine (n = 17) and in a first-in-man feasibility study (n = 18). In the pre-clinical testing EtOH was infused bilaterally with one infusion per renal artery into to the perivascular space, using EtOH doses of 0.3 ml/artery (n = 8), and 0.6 ml/artery (n = 9), and with saline sham control (0.4 ml/artery n = 3). Renal parenchymal norepinephrine (NE) concentration (performed blindly), and safety were the primary endpoints. Data from the first-in-man study (n = 18) to evaluate device performance, safety and peri-procedural pain are reported. RESULTS: In the pre-clinical testing renal function was unchanged at 3-month follow-up. Angiography at 90 days (n = 34 arteries) demonstrated normal appearing renal arteries, unchanged from baseline, and without stenosis or other abnormalities. The reductions in mean renal parenchymal NE reductions at 3 months were 68% and 88% at doses of 0.3 and 0.6 ml, respectively (p < 0.001 vs. controls). In the first-in-man study, there was 100% device success, no complications, a mean treatment time of 4.3 ± 3 minutes/artery, and minimal or no patient discomfort during treatment. Angiography at 6-months showed no evidence of renal artery stenosis, and evidence of a reduction of blood pressure from baseline. CONCLUSION: Perivascular RDN using micro-doses of alcohol is a promising alternative to energy-based systems to achieve dose-dependent, predictable, safe and essentially painless renal denervation. Further clinical evaluation is warranted. SUMMARY: (For annotated table of contents) This paper describes the preclinical results, in a porcine model, and the early first-in-man results, using the Peregrine™ chemical renal denervation catheter to perform renal sympathetic denervation using micro-doses of alcohol.


Assuntos
Etanol/farmacologia , Rim/cirurgia , Obstrução da Artéria Renal/terapia , Artéria Renal/patologia , Simpatectomia , Adulto , Animais , Pressão Sanguínea/fisiologia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Denervação , Etanol/administração & dosagem , Humanos , Hipertensão/fisiopatologia , Rim/patologia , Artéria Renal/cirurgia , Obstrução da Artéria Renal/patologia , Suínos , Simpatectomia/instrumentação , Simpatectomia/métodos
5.
EuroIntervention ; 9(1): 140-7, 2013 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-23685302

RESUMO

AIMS: We report the use of a novel endovascular approach using chemical neurolysis, via periadventitial injection of dehydrated ethanol (EtOH) to perform renal artery denervation. METHODS AND RESULTS: A novel, three-needle delivery device was introduced into the renal arteries of adult swine using fluoroscopic guidance. EtOH was injected bilaterally with one injection per artery, via the three needles into the adventitial and periadventitial space, using EtOH doses 0.15 ml/artery; n=3, 0.30 ml/artery; n=3, and 0.60 ml/artery; n=3, with saline injection as a sham control (0.4 ml/artery; n=3), and naive subjects (n=7) as a true negative control. The renal parenchymal norepinephrine (NE) concentration at two-week follow-up was the primary efficacy endpoint. The mean renal NE reduction was 54%, 78% and 88% at doses of 0.15 ml, 0.30 ml and 0.60 ml, respectively (p<0.0001 vs. controls). Histological examination revealed marked, and deep, circumferential renal nerve injury at depths of 2-8 mm from the intimal surface. There was no evidence of device-related or EtOH-induced injury to the intimal layers. In some samples at the higher EtOH doses, there was focal loss of smooth muscle cells in the outer media. Angiography at 45 days demonstrated normal appearing renal arteries with no detectable stenoses (n=8). CONCLUSIONS: Circumferential adventitial delivery of very low doses of EtOH may be a promising alternative to energy-based systems to achieve dose-dependent, and predictable renal denervation. Further study is warranted.


Assuntos
Técnicas de Ablação , Procedimentos Endovasculares , Etanol/administração & dosagem , Rim/irrigação sanguínea , Rim/inervação , Simpatectomia Química/métodos , Animais , Relação Dose-Resposta a Droga , Rim/metabolismo , Rim/patologia , Modelos Animais , Norepinefrina/metabolismo , Artéria Renal , Suínos , Fatores de Tempo
6.
J Am Coll Cardiol ; 56(14): 1089-98, 2010 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-20863952

RESUMO

OBJECTIVES: We report the first clinical studies of intracardiac ST-segment monitoring in ambulatory humans to alert them to significant ST-segment shifts associated with thrombotic occlusion. BACKGROUND: Despite improvements in door-to-balloon times, delays in symptom-to-door times of 2 to 3 h remain. Early alerting of the presence of acute myocardial infarction could prompt patients to seek immediate medical evaluation. METHODS: Intracardiac monitoring was performed in 37 patients at high risk for acute coronary syndromes. The implanted monitor continuously evaluated the patients' ST segments sensed from a conventional pacemaker right ventricle apical lead, and alerted patients to detected ischemic events. RESULTS: During follow-up (median 1.52 years, range 126 to 974 days), 4 patients had ST-segment changes of ≥3 SDs of their normal daily range, in the absence of an elevated heart rate. This in combination with immediate hospital monitoring led to angiogram and/or intravascular ultrasonography, which confirmed thrombotic coronary occlusion/ruptured plaque. The median alarm-to-door time was 19.5 min (6, 18, 21, and 60 min, respectively). Alerting for demand-related ischemia at elevated heart rates, reflective of flow-limiting coronary obstructions, occurred in 4 patients. There were 2 false-positive ischemia alarms related to arrhythmias, and 1 alarm due to a programming error that did not prompt cardiac catheterization. CONCLUSIONS: Shifts exceeding 3 SD from a patient's daily intracardiac ST-segment range may be a sensitive/specific marker for thrombotic coronary occlusion. Patient alerting was associated with a median alert-to-door time of 19.5 min for patients at high risk of recurrent coronary syndromes who typically present with 2- to 3-h delays.


Assuntos
Síndrome Coronariana Aguda/prevenção & controle , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia Ambulatorial/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Isquemia Miocárdica/diagnóstico , Idoso , Doença da Artéria Coronariana/prevenção & controle , Técnicas Eletrofisiológicas Cardíacas/métodos , Desenho de Equipamento , Segurança de Equipamentos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Isquemia Miocárdica/prevenção & controle , Recidiva , Medição de Risco , Ruptura Espontânea
7.
J Am Coll Cardiol ; 48(11): 2306-14, 2006 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-17161264

RESUMO

OBJECTIVES: The purpose of this study was to evaluate feasibility of using real-time, high-fidelity, intracardiac electrogram monitoring from a permanently implantable ischemia detection system (IIDS), with long-range telemetry capability to detect ST-segment shifts associated with acute or subacute coronary occlusion in a porcine model. BACKGROUND: Early identification of coronary occlusion with ST-segment elevation could profoundly accelerate the timing of revascularization and improve clinical outcomes. METHODS: This paper reports the first investigation using real-time, high-fidelity, intracardiac electrogram monitoring from a permanently IIDS, with long-range telemetry capability. This IIDS was tested in an ambulatory porcine model, with acute coronary occlusion precipitated by stent thrombosis. Two overlapping copper stents were implanted in the left anterior descending (n = 3), the circumflex (n = 3), or the right coronary artery (n = 2) of juvenile farm pigs. Monitoring was carried using telemetry from the IIDS. RESULTS: All stented pigs had acute ST-segment elevation event(s) triggering the alerting thresholds of the IIDS. All triggered events were confirmed to be caused by thrombosis of the copper stent(s), and well correlated to infarct age and location. Four of the 8 pigs died from ventricular fibrillation, recorded by the IIDS at a mean time of 70 +/- 121 h after ST-segment alert. The sensitivity and specificity of alerting for ST-segment shift, associated with thrombotic coronary occlusion, were 100% and 100%, respectively. CONCLUSIONS: This study demonstrates the ability of an implantable ischemia detection system to detect ST-segment elevation from coronary occlusion in a porcine model of ST-segment elevation myocardial infarction. ST-segment elevation was sufficient to trigger alerting thresholds in all 3 epicardial coronary distributions. Such a system, with real-time alerting capability, could advance the time frame of reperfusion therapy and potentially prevent, rather than interrupt, acute myocardial infarction in patients with coronary artery disease.


Assuntos
Sistemas Computacionais , Eletrocardiografia , Eletrodiagnóstico , Monitorização Ambulatorial , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Telemetria , Doença Aguda , Animais , Doença das Coronárias/diagnóstico , Doença das Coronárias/etiologia , Trombose Coronária/complicações , Limiar Diferencial , Desenho de Equipamento , Estudos de Viabilidade , Monitorização Ambulatorial/instrumentação , Isquemia Miocárdica/terapia , Próteses e Implantes , Sensibilidade e Especificidade , Stents , Suínos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA