Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
PLoS One ; 19(9): e0308306, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39241043

RESUMO

Paint is a versatile material that can be used to coat surfaces for which routine disinfection practices may be lacking. EPA-registered copper-containing supplemental residual antimicrobial paints could be used to reduce the bioburden on often-neglected surfaces. An interventional study was conducted by painting the walls of a preschool restroom and metal locker surfaces in two hospital locker rooms with a copper-containing antimicrobial paint to evaluate the potential for bioburden reduction compared to a non-copper-containing control paint. The antimicrobial paint reduced the bioburden on the preschool restroom walls by 57% and on lockers in one locker room by 63% compared to the control paint; no significant difference was observed between the two paint types in the second locker room. The upper quartile bacterial counts, which drive the overall risk by increasing exposure to pathogens, also exhibited 63% and 47% reductions for the antimicrobial paint compared to the control paint in the preschool restroom and the first locker room, respectively. Because detectible levels of bioburden are found on large-area surfaces such as walls and lockers, surfaces painted with copper-containing paints may make large-area surfaces that are prone to contamination safer in a way that is practical and economical.


Assuntos
Anti-Infecciosos , Desinfecção , Pintura , Pintura/análise , Desinfecção/métodos , Anti-Infecciosos/farmacologia , Humanos , Cobre/farmacologia , Propriedades de Superfície
2.
J Recept Signal Transduct Res ; 29(3-4): 202-10, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19640222

RESUMO

The Epic system, a high-throughput label-free optical biosensor system, is applied for the biochemical interrogation of phosphor-specific interactions of the 14-3-3 protein and its substrates. It has shown the capability not only for high-throughput characterization of binding rank and affinity but also for the exploration of potential interacting kinases for the substrates. A perspective of biochemical applications for diagnostics and biomarker discovery, as well as cell-based applications for endogenous receptors and viral infection characterization, are also provided.


Assuntos
Proteínas 14-3-3/metabolismo , Técnicas Biossensoriais , Proteínas Quinases Dependentes de AMP Cíclico/metabolismo , Peptídeos/metabolismo , Linhagem Celular Tumoral , Humanos , Fosforilação
3.
J Biomol Screen ; 12(1): 117-25, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17175523

RESUMO

Refractive index-sensitive resonant waveguide grating biosensors are used to assay the label-free enzymatic degradation of biomolecules. These assays provide a robust means of screening for functional lytic modulators. The biomolecular substrates in this study were covalently immobilized through amine groups. Using the Corning Epic System, the digestion signatures for multiple protein substrates on the biosensors are measured. Label-free digestion profiles for these proteins were substrate specific. Similarly, the authors find that the label-free digestion is protease specific. Enzyme-substrate pairs were used to evaluate high- throughput biosensors as tools for screening functional modulators. The lytic inhibitor properties for several proteases and dextranase are determined. The authors find that the IC50 values for the protease inhibitors agree with the reported values for several known inhibitors. The Z' values, using biosensor-based functional lytic screens, were routinely greater than 0.5, making this label-free application feasible for high-throughput screening.


Assuntos
Bioensaio/métodos , Metabolismo dos Carboidratos , Sondas Moleculares/metabolismo , Processamento de Proteína Pós-Traducional , Proteínas/metabolismo , Animais , Técnicas Biossensoriais , Metabolismo dos Carboidratos/efeitos dos fármacos , Bovinos , Dextranase/metabolismo , Humanos , Peptídeo Hidrolases/metabolismo , Inibidores de Proteases/análise , Inibidores de Proteases/farmacologia , Especificidade por Substrato , Tripsina/metabolismo
4.
FEBS Lett ; 580(24): 5681-9, 2006 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-17011553

RESUMO

Label-free detection of molecular interactions has considerable potential in facilitating assay development. When combined with high throughput capability, it may be applied to small molecule screens for drug candidates. Phosphorylation is a key posttranslational process that confers diverse regulation in biological systems involving specific protein-protein interactions recognizing the phosphorylated motifs. Using a resonant waveguide grating biosensor, the Epic mark System, we have developed a generic assay to quantitatively measure phospho-specific interactions between a trafficking signal-phosphorylated SWTY peptide and 14-3-3 proteins or anti-phosphopeptide antibodies. Compared with a solution-based fluorescence anisotropy assay, our results support that the high throughput resonant waveguide grating biosensor system has favorable technical profiles in detecting protein-protein interactions that recognize phosphorylated motifs. Hence it provides a new generic HTS platform for phospho-detection.


Assuntos
Proteínas 14-3-3/imunologia , Proteínas 14-3-3/metabolismo , Anticorpos Fosfo-Específicos/imunologia , Técnicas Biossensoriais/métodos , Estrutura Molecular , Fosfopeptídeos/química , Fosfopeptídeos/metabolismo , Fosforilação , Ligação Proteica , Sensibilidade e Especificidade
5.
Biotechniques ; Suppl: 62-5, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12514931

RESUMO

Membrane-bound proteins represent the single most important class of drug targets. This article discusses the issues surrounding fabrication of membrane-protein microarrays by conventional robotic pin printing techniques. Ligand binding selectivity and specificity to G protein-coupled receptor (GPCR) microarrays are presented. The potential applications of these arrays for drug screening are discussed.


Assuntos
Proteínas de Ligação ao GTP/química , Análise Serial de Proteínas/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Humanos , Ligantes , Proteínas de Membrana/química , Membranas Artificiais , Análise Serial de Proteínas/métodos , Proteínas/análise , Proteínas/química , Receptores Adrenérgicos beta 1/análise , Receptores Adrenérgicos beta 1/química , Receptores de Superfície Celular/química , Receptores de Dopamina D1/análise , Receptores de Dopamina D1/química , Receptores de Neurotensina/análise , Receptores de Neurotensina/química
6.
Methods Mol Biol ; 264: 233-43, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15020794

RESUMO

The increased number of drug targets and compounds demands novel high-throughput screening technologies that could be used for parallel analysis of many genes and proteins. Protein microarrays are evolving promising technologies for the parallel analysis of many proteins with respect to their abundance, location, modifications, and interactions with other biological and chemical molecules. This chapter specifically describes the fabrication of G protein-coupled receptor (GPCR) microarrays, a unique subset of protein microarrays, using contact-pin printing technology. The bioassays and potential applications of GPCR microarrays for the determination of compound affinities and potencies are also included.


Assuntos
Análise Serial de Proteínas/métodos , Receptores Acoplados a Proteínas G/análise , Animais , Soluções Tampão , Humanos , Ligantes , Análise Serial de Proteínas/instrumentação , Ligação Proteica
7.
Comb Chem High Throughput Screen ; 11(5): 357-69, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18537557

RESUMO

G protein-coupled receptors (GPCRs) have been proven to be the largest family of druggable targets in the human genome. Given the importance of GPCRs as drug targets and the de-orphanization of novel targets, GPCRs are likely to remain the frequent targets of many drug discovery programs. With recent advances in instrumentation and understanding of cellular mechanisms for the signals measured, biosensor-centered label-free cell assay technologies become a very active area for GPCR screening. This article reviews the principles and potential of current label-free cell assay technologies in GPCR drug discovery.


Assuntos
Bioensaio/métodos , Descoberta de Drogas/métodos , Receptores Acoplados a Proteínas G/metabolismo , Animais , Bioensaio/instrumentação , Células/metabolismo , Descoberta de Drogas/instrumentação , Eletroquímica , Humanos , Transdução de Sinais , Coloração e Rotulagem
8.
Chembiochem ; 3(10): 987-91, 2002 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-12362364

RESUMO

Membrane-bound proteins represent the single most important class of drug targets. Arraying these proteins is difficult because they typically need to be embedded in membranes to maintain their correctly folded conformations. We describe here the fabrication of microarrays consisting of G-protein-coupled receptors (GPCRs)--the single largest family of membrane-bound proteins-by robotic pin-printing on slides, and demonstrate assays for screening of ligands on these arrays.


Assuntos
Proteínas de Ligação ao GTP/análise , Proteínas de Ligação ao GTP/metabolismo , Análise Serial de Proteínas/métodos , Receptores de Superfície Celular/análise , Receptores de Superfície Celular/metabolismo , Ligação Competitiva , Polarização de Fluorescência , Proteínas de Ligação ao GTP/química , Ligantes , Metabolismo dos Lipídeos , Lipídeos/química , Neurotensina/química , Neurotensina/metabolismo , Neurotensina/farmacologia , Fragmentos de Peptídeos/metabolismo , Análise Serial de Proteínas/instrumentação , Receptores Adrenérgicos/metabolismo , Receptores de Superfície Celular/química , Receptores de Neurotensina/metabolismo , Rodaminas/química , Rodaminas/farmacologia , Sensibilidade e Especificidade , Silanos/química , Especificidade por Substrato
9.
J Am Chem Soc ; 124(11): 2394-5, 2002 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-11890761

RESUMO

This paper describes the fabrication of microarrays consisting of G protein-coupled receptors (GPCRs) on surfaces coated with gamma-aminopropylsilane (GAPS). Microspots of model membranes on GAPS-coated surfaces were observed to have several desired properties-high mechanical stability, long range lateral fluidity, and a thickness corresponding to a lipid bilayer in the bulk of the microspot. GPCR arrays were obtained by printing membrane preparations containing GPCRs using a quill-pin printer. To demonstrate specific binding of ligands, arrays presenting neurotensin (NTR1), adrenergic (beta1), and dopamine (D1) receptors were treated with fluorescently labeled neurotensin (BT-NT). Fluorescence images revealed binding only to microspots corresponding to the neurotensin receptor; this specificity was further demonstrated by the inhibition of binding in the presence of excess unlabeled neurotensin. The ability of GPCR arrays to enable selectivity studies between the different subtypes of a receptor was examined by printing arrays consisting of three subtypes of the adrenergic receptor: beta1, beta2, and alpha2A. When treated with fluorescently labeled CGP 12177, a cognate antagonist analogue specific to beta-adrenergic receptors, binding was only observed to microspots of the beta1 and beta2 receptors. Furthermore, binding of labeled CGP 12177 was inhibited when the arrays were incubated with solutions also containing ICI 118551, and in a manner consistent with the higher affinity of ICI 118551 for the beta2 receptor relative to that for the beta1 receptor. The ability to estimate binding affinities of compounds using GPCR arrays was examined using a competitive binding assay with BT-NT and unlabeled neurotensin on NTR1 arrays. The estimated IC(50) value (2 nM) for neurotensin is in agreement with the literature; this agreement suggests that the receptor -G protein complex is preserved in the microspot. This first ever demonstration of direct pin-printing of membrane proteins and ligand-binding assays thereof fills a significant void in protein microchip technology--the lack of practical microarray-based methods for membrane proteins.


Assuntos
Proteínas de Membrana/análise , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Fluorescência , Proteínas de Ligação ao GTP/química , Proteínas de Ligação ao GTP/genética , Proteínas de Ligação ao GTP/metabolismo , Ligantes , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Fosfatidilcolinas/química , Receptores de Superfície Celular/química , Receptores de Superfície Celular/genética , Receptores de Superfície Celular/metabolismo
10.
J Am Chem Soc ; 124(11): 2396-7, 2002 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-11890762

RESUMO

This paper describes a method for the detection of single-base mismatches using DNA microarrays in a format that does not require labeling of the sample ("target") DNA. The method is based on disrupting fluorescence energy transfer (FRET) between a fluorophore attached to an immobilized DNA strand ("probe") and a quencher-containing sequence that is complementary except for an artificial mismatch (e.g. 5-nitroindole, 3-nitropyrole, or abasic site) at the site of interrogation. As the displacement of the FRET acceptor and hybridization of the unlabeled probe are bimolecular, the term "bimolecular beacons" is used to describe this approach. The analysis of a mismatch was based on differences in the amount of disruption in FRET upon hybridization of perfectly matched DNA targets and those containing single-base mismatches. Using this method and an oligonucleotide model system, A/C single-base mismatches were successfully discriminated at levels greater than that observed using surface-immobilized molecular beacons. The amount of discrimination was dependent on the identity of the artificial mismatch; greater discrimination was observed with 5-nitroindole (a "universal" base) than with an abasic site. G/T mismatches, considered to be particularly difficult to detect, were also successfully discriminated when quencher sequences containing 5-nitroindole were used.


Assuntos
Pareamento Incorreto de Bases , DNA/análise , DNA/genética , Análise de Sequência com Séries de Oligonucleotídeos/métodos , DNA/química , Sondas de DNA/química , Transferência de Energia , Fluorescência , Corantes Fluorescentes/química
11.
Anal Chem ; 74(8): 1792-7, 2002 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-11985309

RESUMO

The application of resonance light scattering (RLS) particles for high-sensitivity detection of DNA hybridization on cDNA microarrays is demonstrated. Arrays composed of approximately 2000 human genes ("targets") were hybridized with colabeled (Cy3 and biotin) human lung cDNA probes at concentrations ranging from 8.3 ng/microL to 16.7 pg/microL. After hybridization, the arrays were imaged using a fluorescence scanner. The arrays were then treated with 80-nm-diameter gold RLS Particles coated with anti-biotin antibodies and imaged in a white light, CCD-based imaging system. At low probe concentrations, significantly more genes were detected by RLS compared to labeling by Cy3. For example, for hybridizations with a probe concentration of 83.3 pg/microL, approximately 1150 positive genes were detected using RLS compared to approximately 110 positive genes detected with Cy3. In a differential gene expression experiment using human lung and leukemia RNA samples, similar differential expression profiles were obtained for labeling by RLS and fluorescence technologies. The use of RLS Particles is particularly attractive for detection and identification of low-abundance mRNAs and for those applications in which the amount of sample is limited.


Assuntos
Hibridização de Ácido Nucleico/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Sondas de DNA/química , Perfilação da Expressão Gênica/métodos , Humanos , Luz , Pulmão/química , RNA Neoplásico/análise , Espalhamento de Radiação , Sensibilidade e Especificidade
12.
Proc Natl Acad Sci U S A ; 100(2): 389-93, 2003 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-12515864

RESUMO

The development of ultraminiaturized identification tags has applications in fields ranging from advanced biotechnology to security. This paper describes micrometer-sized glass barcodes containing a pattern of different fluorescent materials that are easily identified by using a UV lamp and an optical microscope. A model DNA hybridization assay using these "microbarcodes" is described. Rare earth-doped glasses were chosen because of their narrow emission bands, high quantum efficiencies, noninterference with common fluorescent labels, and inertness to most organic and aqueous solvents. These properties and the large number (>1 million) of possible combinations of these microbarcodes make them attractive for use in multiplexed bioassays and general encoding.


Assuntos
DNA/genética , Metais Terras Raras , Hibridização de Ácido Nucleico/métodos , Biotecnologia , Corantes Fluorescentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA