Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Pacing Clin Electrophysiol ; 43(5): 471-478, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32198771

RESUMO

BACKGROUND: Permanent right ventricular pacing (RVP) results in cardiac dyssynchrony that may lead to heart failure and may be an indication for the use of cardiac resynchronization therapy (CRT). The study aimed to evaluate predictors of outcomes in patients with pacing-induced cardiomyopathy (PICM) if upgraded to CRT. METHODS: One hundred fifteen patients, 75.0 years old (IQR 67.0-80.0), were upgraded to CRT due to the decline in left ventricle ejection fraction (LVEF) caused by the long-term RVP. A retrospective analysis was performed using data from hospital and outpatient clinic records and survival data from the National Health System. RESULTS: The prior percentage of RVP was 100.0% (IQR 97.0-100.0), with a QRS duration of 180.0 ms (IQR 160.0-200.0). LVEF at the time of the upgrade procedure was 27.0% (IQR 21.0-32.75). The mean follow-up was 980 ± 522 days. The primary endpoint, death from any cause, was met by 26 (22%) patients. Age > 82 years (HR 5.96; 95% CI 2.24-15.89; P = .0004) and pre-CRT implantation LVEF < 20% (HR 5.63; 95%CI 2.19-14.47; P = .0003), but neither the cardioverter-defibrillator (ICD) implantation (HR 1.00; 95%CI 0.45-2.22; P = 1.00), nor the presence of atrial fibrillation (HR 1.22; 95%CI 0.56-2.64; P = .62), were independently associated with all-cause mortality. CONCLUSION: Advanced age and an extremely low LVEF, but neither the presence of atrial fibrillation nor implanting an additional high voltage lead, influence the all-cause mortality in patients after long-term RVP, when upgraded to CRT.


Assuntos
Estimulação Cardíaca Artificial/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/etiologia , Cardiomiopatias/terapia , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/terapia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária , Taxa de Sobrevida , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
2.
J Clin Med ; 13(6)2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38542025

RESUMO

Introduction: His bundle pacing (HBP) is suitable for 80% of patients with any indication for permanent pacemaker implantation, with a clinical benefit compared to right ventricular pacing (RVP). Although complications and mortality related to RVP are widely reported in the literature, data on HBP are limited. This study aimed to analyze HBP complications and outcomes in the short-term (up to 30 days) and long-term (up to the following 24 months) follow-up (F/U). Materials and Methods: The study includes 373 patients aged ≥ 18, enrolled from October 2015 to May 2019 in a single-center HBP prospective registry conducted in the Department of Electrocardiology, Upper Silesian Medical Centre of the Medical University of Silesia in Katowice, Poland. Mortality and HBP complications were used as end-points: during hospitalization and up to 30 days (short-term F/U), and for each F/U point-six months, 12 months, and 24 months after the procedure (long-term F/U). Results: Successful HBP was achieved in 252 patients (68%), with an increasing success rate during consecutive years: 57% in 2015-2016 and 73% in 2017-2019. Complications were found in 8.4% of patients (21/252) in short-term F/U and 5.8% (13/224), 5.5% (11/201), and 6.9% (12/174) at six months, 12 months, and 24 months, respectively. There were no deaths during the first 30 days. However, 26 patients (10.3%) died within 24 months. A left ventricular ejection fraction (LVEF) ≤ 34% was the only independent predictor of all-cause mortality or any major complication in the 24-month F/U. Conclusions: This single-center study reported a low risk of mortality and complications associated with HBP at the short-term F/U. However, during the long-term F/U, we observed a higher but acceptable risk of major complications, with a lower LVEF being an independent predictor of the composite end-point of all-cause mortality or any major complication.

3.
Heart Rhythm ; 21(4): 427-435, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38157921

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is a well-established treatment option for patients with cardiac implantable electronic devices (CIED) complications. OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of TLE in CIED infection and non-CIED infection patients. METHODS: Consecutive patients who underwent TLE between 2016 and 2022 entered the EXTRACT Registry. Models of prediction were constructed for periprocedural clinical and procedural success and the incidence of major complications, including death in 30 days. RESULTS: The registry enrolled 504 patients (mean age 66.6 ± 12.8 years; 65.7% male). Complete procedural success was achieved in 474 patients (94.0%) and clinical success in 492 patients (97.6%). The total number of major and minor complications was 16 (3.2%) and 51 (10%), respectively. Three patients (0.6%) died during the procedure. New York Heart Association functional class IV and C-reactive protein levels defined before the procedure were independent predictors of any major complication, including death in 30 days in CIED infection patients. The time since the last preceding procedure and platelet count before the procedure were independent predictors of any major complication, including death in 30 days in non-CIED infection patients. CONCLUSIONS: TLE is safe and successfully performed in most patients, with a low major complication rate. CIED infection patients demonstrate better periprocedural clinical success and complete procedural success. However, CIED infection predicts higher 30-day mortality compared with non-CIED infection patients. Predictors of any major complication, including death in 30 days, differ between CIED infection and non-CIED infection patients.


Assuntos
Desfibriladores Implantáveis , Cardiopatias , Marca-Passo Artificial , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Remoção de Dispositivo/métodos , Cardiopatias/etiologia , Sistema de Registros , Estudos Retrospectivos
4.
Diagnostics (Basel) ; 13(21)2023 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-37958204

RESUMO

Sleep-disordered breathing (SDB), i.e., central sleep apnea (CSA) and obstructive sleep apnea (OSA), affects the prognosis of patients with heart failure with reduced ejection fraction (HFrEF). The study assessed the relationships between heart chamber size or function and respiratory parameters in patients with HFrEF and various types of SDB. The 84 participants were patients aged 68.3 ± 8.4 years (80% men) with an average left ventricular ejection fraction (LVEF) of 25.5 ± 6.85% who qualified for cardioverter-defibrillator implantation with or without cardiac resynchronization therapy. SDB, defined by an apnea-hypopnea index (AHI) ≥ five events/hour, was diagnosed in 76 patients (90.5%); SDB was severe in 31 (36.9%), moderate in 26 (31.0%), and mild in 19 (22.6%). CSA was the most common type of SDB (64 patients, 76.2%). A direct proportional relationship existed only in the CSA group between LVEF or stroke volume (SV) and AHI (p = 0.02 and p = 0.07), and between LVEF or SV and the percentage of total sleep time spent with hemoglobin oxygen saturation < 90% (p = 0.06 and p = 0.07). In contrast, the OSA group was the only group in which right ventricle size showed a positive relationship with AHI (for basal linear dimension [RVD1] p = 0.06), mean duration of the respiratory event (for RVD1 p = 0.03, for proximal outflow diameter [RVOT proximal] p = 0.009), and maximum duration of respiratory event (for RVD1 p = 0.049, for RVOT proximal p = 0.006). We concluded that in HFrEF patients, SDB severity is related to LV systolic function and SV only in CSA, whereas RV size correlates primarily with apnea/hypopnea episode duration in OSA.

5.
Radiother Oncol ; 188: 109857, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37597807

RESUMO

BACKGROUND AND PURPOSE: Despite its increasing popularity, there are limited prospective data on stereotactic arrhythmia radioablation (STAR). In this trial, we assessed the safety and efficacy of STAR in patients with ventricular tachycardia (VT), focusing on early treatment-related grade ≥ 3 adverse events (AE). MATERIALS AND METHODS: This prospective trial was designed for adults with VT recurrence following catheter ablation (CA) despite adequate pharmacotherapy, or contraindications to CA. A single dose of 25 Gy was delivered to the arrhythmia substrate defined on electro-anatomic mapping and cardiac-gated CT. The primary endpoint was safety, defined as two or fewer treatment-related grade ≥ 3 AEs during the first three months in 11 patients. Additional endpoints included treatment efficacy, clinical and biological markers of cardiac injury, and quality of life. RESULTS: Eleven patients with a median age of 67 years, structural heart disease, and a clinically significant recurrence of VT despite adequate pharmacotherapy and 1-4 previous CAs were enrolled between 2020/09 and 2022/10. Following the treatment, one patient developed a possibly treatment-related grade ≥ 3 AE, a grade 4 heart failure exacerbation at 87 days, which resolved after conservative treatment. There was a total 84.3% reduction in VT burden in 10 evaluable patients; however, VT recurrence was eventually observed in eight, and three patients required additional CAs. Three deaths due to unrelated causes were recorded. CONCLUSIONS: STAR appears to be safe and efficient. It is a promising treatment for selected patients; however, long-term outcomes remain to be evaluated, and controlled trials comparing STAR with standards of care are missing.

6.
J Clin Med ; 11(19)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36233590

RESUMO

Pacing-induced cardiomyopathy (PICM) is among the most common right ventricular pacing complications. Upgrading to cardiac resynchronization therapy (CRT) is the recommended treatment option. Conduction system pacing with His bundle pacing (HBP) has the potential to restore synchronous ventricular activation and can be an alternative to biventricular pacing (BVP). Patients with PICM scheduled for a system upgrade to CRT were included in the prospective cohort study. Either HBP or BVP was used for CRT. Electrocardiographic, clinical, and echocardiographic measurements were recorded at baseline and six-month follow-up. HBP was successful in 44 of 53 patients (83%). Thirty-nine patients with HBP and 22 with BVP completed a 6-month follow-up. HBP led to a higher reduction in QRS duration than BVP, 118.3 ± 14.20 ms vs. 150.5 ± 18.64 ms, p < 0.0001. The improvement in New York Heart Association (NYHA) class by one or two was more common in patients with HBP than those with BiV (p = 0.04). Left ventricular ejection fraction (LVEF) improved in BVP patients from 32.9 ± 7.93% to 43.9 ± 8.07%, p < 0.0001, and in HBP patients from 34.9 ± 6.45% to 48.6 ± 7.73%, p < 0.0001. The improvement in LVEF was more considerable in HBP patients than in BVP patients, p = 0.019. The improvement in clinical outcomes and left ventricle reverse remodeling was more significant with HBP than BVP. HBP can be a valid alternative to BVP for upgrade procedures in PICM patients.

7.
Cardiol J ; 2022 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-35997047

RESUMO

BACKGROUND: His bundle pacing (HBP) maintains a physiological activation pattern of ventricular activation, and in patients with intraventricular conduction delay (IVCD) it can normalize wide QRS duration. METHODS: A total of 181 patients from the HBP registry were enrolled into a the study, which was conducted at the Department of Electrocardiology in Katowice, Poland. The patients had left ventricular ejection fraction (LVEF) < 50% and were implanted between November 2015 and April 2019. The HBP indications were as follows: 1) bradycardia and atrioventricular conduction disturbances with expected high pacing burden, 2) IVCD, LVEF ≤ 35%, with an indication for resynchronization therapy, 3) the need to upgrade to resynchronization therapy due to pacing-induced cardiomyopathy. Pacing parameters and echocardiographic and clinical data were assessed for up to 2 years of follow-up (FU). RESULTS: His bundle pacing was successful in 154 (85.1%) patients. Eighty-two patients completed a 6-month FU. The mean age was 70.6 ± 9.23 years, and 79% were males. At 6 months FU LVEF improved from 35.3 ± 8.22% to 43.1 ± 10.14% (p < 0.0001), and indexed left ventricular end-systolic volume (LVESVi) decreased from 63.1 ± 25.21 mL/m² to 51.9 ± 22.79 mL/m² (p < 0.0001). In 53.1%, the LVESVi reduction was greater than 15%. The improvement in LVEF and LVESVi was also observed after 24 months of FU. CONCLUSIONS: His bundle pacing in permanently paced patients when LVEF is reduced below 50% is associated with improvement in LVEF and reverse left ventricle remodeling.

8.
Front Cardiovasc Med ; 9: 874661, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35509272

RESUMO

Background: Stereotactic Arrhythmia Radioablation (STAR) is an emerging treatment modality for patients with sustained ventricular tachycardia (VT) and refractory to treatment with drugs and radiofrequency catheter ablation (RFA). It is believed that up to 12-17% of patients experience recurrence of VT within 1 year of follow-up; thus, novel therapeutic options are needed. The aim of this article is to present initial experience within a novel treatment modality for VT. Case Summary: Two patients with a medical history of coronary artery disease and heart failure with reduced left ventricle (LV) ejection fraction, after implantation of cardioverter-defibrillator (ICD) and previous unsuccessful RFAs owing to sustained VT were admitted to the cardiology department due to recurrence of sustained VT episodes. With electroanatomical mapping (EAM), the VT substrate in LV has been confirmed and specified. In order to determine the target volume for radioablation, contrast-enhanced computed tomography was performed and the arrhythmia substrate was contoured using EAM data. Using the Volumetric Modulated Arc Therapy technique and three 6 MeV flattening filter-free photon beam fields, a single dose of 25 Gy was delivered to the target volume structure located in the apex and anterior apical segments of LV in the first patient and in the apex, anterolateral and inferior apical segments of the second patient. In both cases, volumes of the target structures were comparable. Interrogation of the implanted ICD at follow-up visits throughout 6 months after the treatment revealed no VT episodes in the first patient and sudden periprocedural increase in VT burden with a subsequent gradual decrease of ventricular arrhythmia to only two non-sustained episodes at the end of the follow-up period in case of the second patient. A significant reduction in premature ventricular contractions burden was observed compared to the pre-treatment period. No noticeable deterioration in LV function was noted, nor any adverse effects of radiosurgery associated with the implanted device. Conclusion: The early response to STAR can be unpredictable and probably does not reflect the final outcome of irradiation. Close monitoring of patients, especially in the early period after irradiation is crucial to properly handle potentially harmful early reactions to STAR.

13.
Case Rep Cardiol ; 2012: 347189, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-24826247

RESUMO

Endocardial leads can potentially cause problems during coronary vessels visualization in multislice computed tomography (MSCT) due to a large number of artifacts. Based on presented case, we conclude that it is possible to perform MSCT of coronary arteries and leads visualization despite coexistence of four endocardial leads.

14.
Cardiol J ; 18(1): 90-1, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21305493

RESUMO

A pericardial cyst is, according to the definition, a collection of fluid or blood in the pericardial space (inside the pericardial sac) around the heart. New visualization methods can help in the non-invasive diagnosis of pericardial cysts. Based on a presented case, we conclude that multi-slice computed tomography can have a great impact on the detection of pericardium diseases such as a pericardial cyst.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca , Cisto Mediastínico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Eletrocardiografia , Humanos , Imageamento Tridimensional , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador
15.
Pacing Clin Electrophysiol ; 29(10): 1174-5, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17038149

RESUMO

A variety of etiologies can cause erroneous detection in patients with implantable cardioverter defibrillator (ICDs). Interaction between two endocardial leads is rare and uncommon in causing electrical noise. During a reimplantation procedure of an ICD system in a 68-year-old man, additional electrical signals could be detected. The interaction between two endocardial defibrillation leads was identified as the cause of sensing problems. When it is not possible to extract the nonfunctional endocardial lead during implantation of the new electrode, it should be implanted away and not in parallel from the old one to avoid interaction between them. A variety of etiologies can cause erroneous detection in patiens with ICD. Interaction between two endocardial leads is rare and uncommon to cause electrical noise.


Assuntos
Desfibriladores Implantáveis , Complicações Intraoperatórias/etiologia , Implantação de Prótese , Idoso , Humanos , Masculino , Falha de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA