Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 166
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Magn Reson Med ; 89(6): 2204-2216, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36669882

RESUMO

PURPOSE: To expand on the previously developed B 1 + $$ {\mathrm{B}}_1^{+} $$ -encoding technique, frequency-modulated Rabi-encoded echoes (FREE), to perform accelerated image acquisition by collecting multiple lines of k-space in an echo train. METHODS: FREE uses adiabatic full-passage pulses and a spatially varying RF field to encode unique spatial information without the use of traditional B0 gradients. The original implementation relied on acquiring single lines of k-space, leading to long acquisitions. In this work, an acceleration scheme is presented in which multiple echoes are acquired in a single shot, analogous to conventional fast spin-echo sequences. Theoretical analysis and computer simulations investigated the feasibility of this approach and presented a framework to analyze important imaging parameters of FREE-based sequences. Experimentally, the multi-echo approach was compared with conventional phase-encoded images of the human visual cortex using a simple surface transceiver coil. Finally, different contrasts demonstrated the clinical versatility of the new accelerated sequence. RESULTS: Images were acquired with an acceleration factor of 3.9, compared with the previous implementation of FREE, without exceeding specific absorption rate limits. Different contrasts can easily be acquired without major modifications, including inversion recovery-type images. CONCLUSION: FREE initially illustrated the feasibility of performing slice-selective 2D imaging of the human brain without the need for a B0 gradient along the y-direction. The multi-echo version maintains the advantages that B 1 + $$ {\mathrm{B}}_1^{+} $$ encoding provides but represents an important step toward improving the clinical feasibility of such sequences. Additional acceleration and more advanced reconstruction techniques could further improve the clinical viability of FREE-based techniques.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Cabeça , Simulação por Computador , Aceleração , Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas
2.
Magn Reson Med ; 89(5): 2100-2108, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36517956

RESUMO

PURPOSE: To correct image distortions that result from nonlinear spatial variation in the transmit RF field amplitude ( B 1 + $$ {B}_1^{+} $$ ) when performing spatial encoding with the method called frequency-modulated Rabi encoded echoes (FREE). THEORY AND METHODS: An algorithm developed to correct image distortion resulting from the use of nonlinear static field (B0 ) gradients in standard MRI is adapted herein to correct image distortion arising from a nonlinear B 1 + $$ {B}_1^{+} $$ -gradient field in FREE. From a B 1 + $$ {B}_1^{+} $$ -map, the algorithm performs linear interpolation and intensity scaling to correct the image. The quality of the distortion correction is evaluated in 1.5T images of a grid phantom and human occipital lobe. RESULTS: An expanded theoretical description of FREE revealed the symmetry between this B 1 + $$ {B}_1^{+} $$ -gradient field spatial-encoding and standard B0 -gradient field spatial-encoding. The adapted distortion-correction algorithm substantially reduced image distortions arising in the spatial dimension that was encoded by the nonlinear B 1 + $$ {B}_1^{+} $$ gradient of a circular surface coil. CONCLUSION: Image processing based on straightforward linear interpolation and intensity scaling, as previously applied in conventional MRI, can effectively reduce distortions in FREE images acquired with nonlinear B 1 + $$ {B}_1^{+} $$ -gradient fields.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Imagens de Fantasmas
3.
Magn Reson Med ; 90(4): 1728-1737, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37350426

RESUMO

PURPOSE: To improve intraoral transverse loop coil design for high-resolution dental MRI. METHODS: The transverse intraoral loop coil (tLoop) was modified (mtLoop) by overlapping the feed port conductors, bending the posterior section, introducing a parallel plate capacitor, optimizing the insulation thickness, and using it in receive-only mode. In addition, an MR-silent insulation was introduced. The performances of the mtLoop and tLoop coils were compared in terms of sensitivity, image SNR, and eddy currents using electromagnetic simulations and MRI measurements at 3T. RESULTS: The receive-only mode of the mtLoop increases the sensitivity at the apices of the roots, and the overlapped feed port design eliminated signal voids along the incisors. The bent posterior section with the parallel plate capacitor reduced the unwanted signal of the tongue by a factor of 2.3 in the selected region off interest and lowered the eddy currents by 10%. The proposed new coil provided higher SNR by elevenfold and 2.5-fold at the incisors and apices of the molar roots within the selected regions of interest, respectively, in the experiments, as well as improved comfort. Optimal insulation thickness was determined as 1 mm. With the mtLoop, a (250 µm)3 isotropic resolution of the dental arch could be realized using a UTE sequence within 2 min total acquisition time. A T2 -SPACE protocol with (350 µm)2 in-plane resolution was also demonstrated. CONCLUSION: The proposed new coil offers higher SNR at the incisors and apices of the molar roots, less unwanted signals from tongue, lower eddy currents, and improved patient comfort.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Humanos , Desenho de Equipamento , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos
4.
Magn Reson Med ; 90(2): 708-721, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37145027

RESUMO

PURPOSE: Recent studies indicate that T1 in white matter (WM) is influenced by fiber orientation in B0 . The purpose of the study was to investigate the interrelationships between axon fiber orientation in corpus callosum (CC) and T1 relaxation time in humans in vivo as well as in rat brain ex vivo. METHODS: Volunteers were scanned for relaxometric and diffusion MRI at 3 T and 7 T. Angular T1 plots from WM were computed using fractional anisotropy and fiber-to-field-angle maps. T1 and fiber-to-field angle were measured in five sections of CC to estimate the effects of inherently varying fiber orientations on T1 within the same tracts in vivo. Ex vivo rat-brain preparation encompassing posterior CC was rotated in B0 and T1 , and diffusion MRI images acquired at 9.4 T. T1 angular plots were determined at several rotation angles in B0 . RESULTS: Angular T1 plots from global WM provided reference for estimated fiber orientation-linked T1 changes within CC. In anterior midbody of CC in vivo, where small axons are dominantly present, a shift in axon orientation is accompanied by a change in T1 , matching that estimated from WM T1 data. In CC, where large and giant axons are numerous, the measured T1 change is about 2-fold greater than the estimated one. Ex vivo rotation of the same midsagittal CC region of interest produced angular T1 plots at 9.4 T, matching those observed at 7 T in vivo. CONCLUSION: These data causally link axon fiber orientation in B0 to the T1 relaxation anisotropy in WM.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Anisotropia , Axônios , Imagem de Difusão por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem
5.
NMR Biomed ; 36(1): e4815, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35994269

RESUMO

A high degree of structural order by white matter (WM) fibre tracts creates a physicochemical environment where water relaxations are rendered anisotropic. Recently, angularly dependent longitudinal relaxation has been reported in human WM. We have characterised interrelationships between T1 relaxation and diffusion MRI microstructural indices at 3 and 7 T. Eleven volunteers consented to participate in the study. Multishell diffusion MR images were acquired with b-values of 0/1500/3000 and 0/1000/2000 s/mm2 at 1.5 and 1.05 mm3 isotropic resolutions at 3 and 7 T, respectively. DTIFIT was used to compute DTI indices; the fibre-to-field angle (θFB ) maps were obtained using the principal eigenvector images. The orientations and volume fractions of multiple fibre populations were estimated using BedpostX in FSL, and the orientation dispersion index (ODI) was estimated using the NODDI protocol. MP2RAGE was used to acquire images for T1 maps at 1.0 and 0.9 mm3 isotropic resolutions at 3 and 7 T, respectively. At 3 T, T1 as a function of θFB in WM with high fractional anisotropy and one-fibre orientation volume fraction or low ODI shows a broad peak centred at 50o , but a flat baseline at 0o and 90o . The broad peak amounted up to 7% of the mean T1. At 7 T, the broad peak appeared at 40o and T1 in fibres running parallel to B0 was longer by up to 75 ms (8.3% of the mean T1) than in those perpendicular to the field. The peak at 40o was approximately 5% of mean T1 (i.e., proportionally smaller than that at 54o at 3 T). The data demonstrate T1 anisotropy in WM with high microstructural order at both fields. The angular patterns are indicative of the B0-dependency of T1 anisotropy. Thus myelinated WM fibres influence T1 contrast both by acting as a T1 contrast agent and rendering T1 dependent on fibre orientation with B0.


Assuntos
Substância Branca , Humanos , Substância Branca/diagnóstico por imagem
6.
Neuroimage ; 250: 118924, 2022 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-35065267

RESUMO

Understanding the link between the brain activity and behavior is a key challenge in modern neuroscience. Behavioral neuroscience, however, lacks tools to record whole-brain activity in complex behavioral settings. Here we demonstrate that a novel Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) functional magnetic resonance imaging (fMRI) approach enables whole-brain studies in spontaneously behaving head-fixed rats. First, we show anatomically relevant functional parcellation. Second, we show sensory, motor, exploration, and stress-related brain activity in relevant networks during corresponding spontaneous behavior. Third, we show odor-induced activation of olfactory system with high correlation between the fMRI and behavioral responses. We conclude that the applied methodology enables novel behavioral study designs in rodents focusing on tasks, cognition, emotions, physical exercise, and social interaction. Importantly, novel zero echo time and large bandwidth approaches, such as MB-SWIFT, can be applied for human behavioral studies, allowing more freedom as body movement is dramatically less restricting factor.


Assuntos
Comportamento Animal/fisiologia , Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/instrumentação , Animais , Eletroencefalografia , Desenho de Equipamento , Movimentos da Cabeça , Ratos , Ratos Sprague-Dawley
7.
Magn Reson Med ; 87(2): 674-685, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34498768

RESUMO

PURPOSE: Reduce expense and increase accessibility of MRI by eliminating pulsed field (B0 ) gradient hardware. METHODS: A radiofrequency imaging method is described that enables spatial encoding without B0 gradients. This method, herein referred to as frequency-modulated Rabi-encoded echoes (FREE), utilizes adiabatic full passage pulses and a gradient in the RF field (B1 ) to produce spatially dependent phase modulation, equivalent to conventional phase encoding. In this work, Cartesian phase encoding was accomplished using FREE in a multi-shot double spin-echo sequence. Theoretical analysis and computer simulations investigated the influence of resonance offset and B1 -gradient steepness and magnitude on reconstruction quality, which limit other radiofrequency imaging methodologies. Experimentally, FREE was compared to conventional phase-encoded MRI on human visual cortex using a simple surface transceiver coil. RESULTS: Image distortions occurred in FREE when using nonlinear B1 fields where the phase dependence becomes nonlinear, but with minimal change in signal intensity. Resonance offset effects were minimal for Larmor frequencies within the adiabatic full-passage pulse bandwidth. CONCLUSION: For the first time, FREE enabled slice-selective 2D imaging of the human brain without a B0 gradient in the y-direction. FREE achieved high resolution in regions where the B1 gradient was steepest, whereas images were distorted in regions where nonlinearity in the B1 gradient was significant. Given that FREE experiences no significant signal loss due to B1 nonlinearities and resonance offset, image distortions shown in this work might be corrected in the future based on B1 and B0 maps.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Simulação por Computador , Humanos , Imagens de Fantasmas
8.
Neuroimage ; 238: 118210, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34062266

RESUMO

Smaller, more affordable, and more portable MRI brain scanners offer exciting opportunities to address unmet research needs and long-standing health inequities in remote and resource-limited international settings. Field-based neuroimaging research in low- and middle-income countries (LMICs) can improve local capacity to conduct both structural and functional neuroscience studies, expand knowledge of brain injury and neuropsychiatric and neurodevelopmental disorders, and ultimately improve the timeliness and quality of clinical diagnosis and treatment around the globe. Facilitating MRI research in remote settings can also diversify reference databases in neuroscience, improve understanding of brain development and degeneration across the lifespan in diverse populations, and help to create reliable measurements of infant and child development. These deeper understandings can lead to new strategies for collaborating with communities to mitigate and hopefully overcome challenges that negatively impact brain development and quality of life. Despite the potential importance of research using highly portable MRI in remote and resource-limited settings, there is little analysis of the attendant ethical, legal, and social issues (ELSI). To begin addressing this gap, this paper presents findings from the first phase of an envisioned multi-staged and iterative approach for creating ethical and legal guidance in a complex global landscape. Section 1 provides a brief introduction to the emerging technology for field-based MRI research. Section 2 presents our methodology for generating plausible use cases for MRI research in remote and resource-limited settings and identifying associated ELSI issues. Section 3 analyzes core ELSI issues in designing and conducting field-based MRI research in remote, resource-limited settings and offers recommendations. We argue that a guiding principle for field-based MRI research in these contexts should be including local communities and research participants throughout the research process in order to create sustained local value. Section 4 presents a recommended path for the next phase of work that could further adapt these use cases, address ethical and legal issues, and co-develop guidance in partnership with local communities.


Assuntos
Imageamento por Ressonância Magnética/ética , Neuroimagem/ética , Países em Desenvolvimento , Ética em Pesquisa , Humanos
9.
Magn Reson Med ; 86(3): 1271-1283, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33780035

RESUMO

PURPOSE: The ability to use dual polarity encoded MRI with the missing pulse steady-state free precession (MP-SSFP) sequence is demonstrated to perform robust MRI with low radiofrequency (RF) amplitude, where the field is distorted by embedding metallic screws in an agar phantom. Image-based estimation of the 3D ΔB0 map and image distortion correction is shown to require ~1 minute to perform. THEORY AND METHODS: Dual polarity encoded MP-SSFP was implemented at 1.5T and used to image agar phantoms with one stainless steel and one titanium screw embedded inside. A multispectral fast spin-echo acquisition was performed for comparison. Self-consistent ΔB0 estimation is performed iteratively using a 3D B-spline basis, which is compared to the ΔB0 estimate generated by the multispectral sequence. RESULTS: Dual polarity encoded MP-SSFP yields image quality similar to the multispectral sequence used with substantially less imaging time, provided the MP-SSFP experimental parameters are chosen well. The multispectral sequence appears to visualize modestly closer in proximity to the metallic screws used, despite the spectral bins covering the same bandwidth as the pulses used in MP-SSFP. However, MP-SSFP avoids ripple artifacts characteristic of the multispectral sequence. The ΔB0 estimate generated by MP-SSFP is qualitatively similar to that generated by the multispectral sequence but larger in magnitude. CONCLUSION: Despite longer processing time compared to multispectral imaging, MP-SSFP yields similar image quality with significantly lower acquisition times in the absence of parallel imaging. The work herein demonstrates the ability to perform 3D ΔB0 estimation and image correction within a reasonable amount of time, ~1 minute.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Artefatos , Imagens de Fantasmas , Reprodutibilidade dos Testes
10.
Magn Reson Med ; 86(1): 17-32, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33497006

RESUMO

PURPOSE: To develop a 3D composite adiabatic spectral-spatial pulse for refocusing in spin-echo spectroscopy acquisitions and to compare its performance against standard acquisition methods. METHODS: A 3D composite adiabatic pulse was designed by modulating a train of parallel transmit-optimized 2D subpulses with an adiabatic envelope. The spatial and spectral profiles were simulated and validated by experiments to demonstrate the feasibility of the design in both single and double spin-echo spectroscopy acquisitions. Phantom and in vivo studies were performed to evaluate the pulse performance and compared with semi-LASER with respect to localization performance, sequence timing, signal suppression, and specific absorption rate. RESULTS: Simultaneous 2D spatial localization with water and lipid suppression was achieved with the designed refocusing pulse, allowing high-quality spectra to be acquired with shorter minimum TE/TR, reduced SAR, as well as adaptation to spatially varying B0 and B1+ field inhomogeneities in both prostate and brain studies. CONCLUSION: The proposed composite pulse can serve as a more SAR efficient alternative to conventional localization methods such as semi-LASER at ultrahigh field for spin echo-based spectroscopy studies. Subpulse parallel-transmit optimization provides the flexibility to manage the tradeoff among multiple design criteria to accommodate different field strengths and applications.


Assuntos
Algoritmos , Encéfalo , Encéfalo/diagnóstico por imagem , Espectroscopia de Ressonância Magnética , Masculino , Imagens de Fantasmas , Próstata
11.
Magn Reson Med ; 85(2): 831-844, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32892400

RESUMO

PURPOSE: We demonstrate the feasibility of MRI with missing-pulse steady-state free precession (MP-SSFP) in a 4T magnet with artificially degraded homogeneity. METHODS: T1 , T2 , and diffusion contrast of MP-SSFP was simulated with constant and alternate radiofrequency (RF) phase using an extended phase graph. To validate MP-SSFP performance in human brain imaging, MP-SSFP was tested with two types of artificially introduced inhomogeneous magnetic fields: (1) a pure linear gradient field, and (2) a pseudo-linear gradient field introduced by mounting a head-gradient set at 36 cm from the magnet isocenter. Image distortion induced by the nonlinear inhomogeneous field was corrected using B0 mapping measured with MP-SSFP. RESULTS: The maximum flip angle in MP-SSFP was limited to ≤10° because of the large range of resonance frequencies in the inhomogeneous magnetic fields tested in this study. Under this flip-angle limitation, MP-SSFP with constant RF phase provided advantages of higher signal-to-noise ratio and insensitivity to B1+ field inhomogeneity as compared with an alternate RF phase. In diffusion simulation, the steady-state magnetization in constant RF phase MP-SSFP increased with an increase of static field gradient up to 8 to 21 mT/m depending on simulation parameters. Experimental results at 4T validated these findings. In human brain imaging, MP-SSFP preserved sufficient signal intensities, but images showed severe image distortion from the pseudo-linear inhomogeneous field. However, following distortion correction, good-quality brain images were achieved. CONCLUSION: MP-SSFP appears to be a feasible MRI technique for brain imaging in an inhomogeneous magnetic field.


Assuntos
Campos Magnéticos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Humanos , Ondas de Rádio , Razão Sinal-Ruído
12.
Neuroimage ; 206: 116338, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31730923

RESUMO

Functional magnetic resonance imaging (fMRI) studies in animal models provide invaluable information regarding normal and abnormal brain function, especially when combined with complementary stimulation and recording techniques. The echo planar imaging (EPI) pulse sequence is the most common choice for fMRI investigations, but it has several shortcomings. EPI is one of the loudest sequences and very prone to movement and susceptibility-induced artefacts, making it suboptimal for awake imaging. Additionally, the fast gradient-switching of EPI induces disrupting currents in simultaneous electrophysiological recordings. Therefore, we investigated whether the unique features of Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) overcome these issues at a high 9.4 T magnetic field, making it a potential alternative to EPI. MB-SWIFT had 32-dB and 20-dB lower peak and average sound pressure levels, respectively, than EPI with typical fMRI parameters. Body movements had little to no effect on MB-SWIFT images or functional connectivity analyses, whereas they severely affected EPI data. The minimal gradient steps of MB-SWIFT induced significantly lower currents in simultaneous electrophysiological recordings than EPI, and there were no electrode-induced distortions in MB-SWIFT images. An independent component analysis of the awake rat functional connectivity data obtained with MB-SWIFT resulted in near whole-brain level functional parcellation, and simultaneous electrophysiological and fMRI measurements in isoflurane-anesthetized rats indicated that MB-SWIFT signal is tightly linked to neuronal resting-state activity. Therefore, we conclude that the MB-SWIFT sequence is a robust preclinical brain mapping tool that can overcome many of the drawbacks of conventional EPI fMRI at high magnetic fields.


Assuntos
Artefatos , Eletroencefalografia/métodos , Neuroimagem Funcional/métodos , Imageamento por Ressonância Magnética/métodos , Movimento , Ruído , Vigília , Anestésicos Inalatórios , Animais , Imagem Ecoplanar , Análise de Fourier , Isoflurano , Masculino , Ratos , Ratos Wistar , Inconsciência
13.
Magn Reson Med ; 84(6): 2953-2963, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32544274

RESUMO

PURPOSE: Spatial encoding for MRI is generally based on linear x, y, and z magnetic field gradients generated by a set of dedicated gradient coils. We recently introduced the dynamic multicoil technique (DYNAMITE) for B0 field control and demonstrated DYNAMITE MRI in a preclinical MR environment. In this study, we report the first realization of DYNAMITE MRI of the in vivo human head. METHODS: Gradient fields for DYNAMITE MRI were generated with a 28-channel multicoil hardware arranged in 4 rows of 7 coils on a cylindrical surface (length 359 mm, diameter 344 mm, maximum 5 A per coil). DYNAMITE MRIs of a resolution phantom and in vivo human heads were acquired with multislice gradient-echo, multislice spin-echo, and 3D gradient-echo sequences. The resultant image fidelity was compared to that obtained with conventional gradient coil technology. RESULTS: DYNAMITE field control enabled the realization of all imaging sequences with average gradient errors ≤ 1%. DYNAMITE MRI provided image quality and sensitivity comparable to conventional gradient technology without any obvious artifacts. Some minor geometric deformations were noticed primarily in the image periphery as the result of regional field imperfections. The imperfections can be readily approximated theoretically through numerical integration of the Biot-Savart law and removed through image distortion correction. CONCLUSION: The first realization of DYNAMITE MRI of the in vivo human head has been presented. The obtained image fidelity is comparable to MRI with conventional gradient coils, paving the way for full-fledged DYNAMITE MRI and B0 shim systems for human applications.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Humanos , Campos Magnéticos , Imagens de Fantasmas
14.
Magn Reson Med ; 83(5): 1750-1759, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31815324

RESUMO

PURPOSE: Herein, we evaluate the use of MRI as a tool for assessing iron oxide nanoparticle (IONP) distribution within IONP perfused organs and vascularized composite allografts (VCAs) (i.e., hindlimbs) prepared for cryopreservation. METHODS: Magnetic resonance imaging was performed on room-temperature organs and VCAs perfused with IONPs and were assessed at 9.4 T. Quantitative T1 mapping and T2∗ -weighted images were acquired using sweep imaging with Fourier transformation and gradient-echo sequences, respectively. Verification of IONP localization was performed through histological assessment and microcomputer tomography. RESULTS: Quantitative imaging was achieved for organs and VCAs perfused with up to 642 mMFe (36 mgFe /mL), which is above previous demonstrations of upper limit detection in agarose (35.7mMFe [2 mgFe /mL]). The stability of IONPs in the perfusate had an effect on the quality of distribution and imaging within organs or VCA. Finally, MRI provided more accurate IONP localization than Prussian blue histological staining in this system, wherein IONPs remain primarily in the vasculature. CONCLUSION: Using MRI, we were able to assess the distribution of IONPs throughout organs and VCAs varying in complexity. Additional studies are necessary to better understand this system and validate the calibration between T1 measurements and IONP concentration.


Assuntos
Nanopartículas de Magnetita , Nanopartículas , Animais , Compostos Férricos , Nanopartículas Magnéticas de Óxido de Ferro , Imageamento por Ressonância Magnética , Coloração e Rotulagem
15.
Magn Reson Med ; 81(3): 1947-1954, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30242896

RESUMO

PURPOSE: The sweep imaging with Fourier transformation (SWIFT) imaging technique has been shown to provide positive contrast from diluted cell suspensions labeled with super-paramagnetic iron oxide (SPIO) in a tissue, as an alternative to T2*-weighted imaging. Here we demonstrate a variation of the SWIFT technique that yields a hyperintense signal from a concentrated cell suspension. The proposed technique provides minimal background signal from host tissue and facilitates visualization of injected cells. METHODS: The proton resonance frequency and linewidth were determined for SPIO solutions of different concentrations. The original SWIFT sequence was modified and a dual saturation Gaussian shape RF pulse with ~200 Hz bandwidth was incorporated into the acquisition protocol to suppress host tissue and fat signals. This modification of the original acquisition protocol permits the detection of a hyperintense signal from grafted cells with minimal background signal from the host tissue. RESULTS: SPIO particles not only induce broadening of NMR line-width but also an initiate proton resonance frequency shift. This shift is linearly proportional to the concentration of the iron oxide particles and induced by the bulk magnetic susceptibility of SPIOs. The shift of the resonance frequency of iron labeled cells allowed us effectively suppress the host tissues with saturation RF pulse to improve MRI detection of grafted cells. CONCLUSIONS: Iron oxide particles increase the resonance frequency of water proton signal. This shift permitted us to add the tissue/fat saturation RF pulse into the original SWIFT acquisition protocol and detect distinct hyperintense signals from grafted cells with minimal background signal from the host tissue.


Assuntos
Compostos Férricos , Processamento de Imagem Assistida por Computador/métodos , Ferro/química , Células-Tronco Mesenquimais/citologia , Animais , Meios de Contraste , Feminino , Ferrocianetos/química , Análise de Fourier , Membro Posterior/patologia , Articulações/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Magnetismo , Nanopartículas de Magnetita/química , Transplante de Células-Tronco Mesenquimais , Camundongos , Imagens de Fantasmas , Ratos
16.
Magn Reson Med ; 79(2): 701-710, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28497465

RESUMO

PURPOSE: To introduce a method of designing single and parallel transmit (pTx) 3D adiabatic π pulses for inverting and refocusing spins that are insensitive to transmit B1 ( B1+) inhomogeneity. THEORY AND METHODS: A 3D adiabatic pulse is created by replacing each piece-wise constant element (or sub-pulse) of an adiabatic full passage (AFP) by a 2D selective pulse. In this study, the parent AFP is an HS1 and each sub-pulse is a 2D pulse derived from a jinc function designed using a spiral k-trajectory. Spatial selectivity in the third direction is achieved by blipping the slab-selective gradient between sub-pulses, yielding a rectangular slab profile identical to that of the parent AFP. The slew-rate limited sub-pulse can be undersampled utilizing pTx, thus shortening the overall pulse width. Simulations and experiments demonstrate the quality of spatial selectivity and adiabaticity achievable. RESULTS: The 3D adiabatic pulse inverts and refocus spins in a sharply demarcated cylindrical volume. When stepping RF amplitude, an adiabatic threshold is observed above which the flip angle remains π. Experimental results demonstrate that pTx is an effective means to significantly improve pulse performance. CONCLUSION: A method of designing 3D adiabatic pulses insensitive to B1 inhomogeneity has been developed. pTx can shorten these pulses while retaining their adiabatic character. Magn Reson Med 79:701-710, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Humanos , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador
17.
Magn Reson Med ; 79(3): 1420-1428, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28653344

RESUMO

PURPOSE: Iron-oxide nanoparticles (IONPs) have shown tremendous utility for enhancing image contrast and delivering targeted therapies. Quantification of IONPs has been demonstrated at low concentrations with gradient echo (GRE) and spin echo (SE), and at high concentrations with echoless sequences such as swept imaging with Fourier transform (SWIFT). This work examines the overlap of IONP quantification with GRE, SE, and SWIFT. METHODS: The limit of quantification of GRE, SE, inversion-recovery GRE, and SWIFT sequences was assessed using IONPs at a concentration range of 0.02 to 89.29 mM suspended in 1% agarose. Empirically derived limits of quantification were compared with International Union of Pure and Applied Chemistry definitions. Both commercial and experimental IONPs were used. RESULTS: All three IONPs assessed demonstrated an overlap of concentration quantification with GRE, SE, and SWIFT sequences. The largest dynamic range observed was 0.004 to 35.7 mM with Feraheme. CONCLUSIONS: The metrics established allow upper and lower quantitative limitations to be estimated given the relaxivity characteristics of the IONP and the concentration range of the material to be assessed. The methods outlined in this paper are applicable to any pulse sequence, IONP formulation, and field strength. Magn Reson Med 79:1420-1428, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Meios de Contraste , Imagens de Fantasmas
18.
Neuroimage ; 159: 443-448, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28797739

RESUMO

Recently introduced 3D radial MRI pulse sequence entitled Multi-Band SWeep Imaging with Fourier Transformation (MB-SWIFT) having virtually zero acquisition delay was used to obtain functional MRI (fMRI) contrast in rat's brain at 9.4 T during deep brain stimulation (DBS). The results demonstrate that MB-SWIFT allows functional images free of susceptibility artifacts, and provides an excellent fMRI activation contrast in the brain. Flip angle dependence of the MB-SWIFT fMRI signal and elimination of the fMRI contrast while using saturation bands, indicate a blood flow origin of the observed fMRI contrast. MB-SWIFT fMRI modality permits activation studies in the close proximity to an implanted lead, which is not possible to achieve with conventionally used gradient echo and spin echo - echo planar imaging fMRI techniques. We conclude that MB-SWIFT fMRI is a powerful imaging modality for investigations of functional responses during DBS.


Assuntos
Encéfalo/diagnóstico por imagem , Estimulação Encefálica Profunda , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Animais , Processamento de Imagem Assistida por Computador/métodos , Ratos , Ratos Sprague-Dawley
19.
Magn Reson Med ; 77(4): 1630-1638, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27171915

RESUMO

PURPOSE: The frequency-swept pulse known as the hyperbolic-secant (HS) pulse is popular in NMR for achieving adiabatic spin inversion. The HS pulse has also shown utility for achieving excitation and refocusing in gradient-echo and spin-echo sequences, including new ultrashort echo-time imaging (e.g., Sweep Imaging with Fourier Transform, SWIFT) and B1 mapping techniques. To facilitate the analysis of these techniques, the complete theoretical solution of the Bloch equation, as driven by the HS pulse, was derived for an arbitrary state of initial magnetization. METHODS: The solution of the Bloch-Riccati equation for transverse and longitudinal magnetization for an arbitrary initial state was derived analytically in terms of HS pulse parameters. The analytical solution was compared with the solutions using both the Runge-Kutta method and the small-tip approximation. RESULTS: The analytical solution was demonstrated on different initial states at different frequency offsets with/without a combination of HS pulses. Evolution of the transverse magnetization was influenced significantly by the choice of HS pulse parameters. The deviation of the magnitude of the transverse magnetization, as obtained by comparing the small-tip approximation to the analytical solution, was < 5% for flip angles < 30 °, but > 10% for the flip angles > 40 °. CONCLUSION: The derived analytical solution provides insights into the influence of HS pulse parameters on the magnetization evolution. Magn Reson Med 77:1630-1638, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Modelos Teóricos , Reconhecimento Automatizado de Padrão/métodos , Simulação por Computador , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
20.
Magn Reson Med ; 77(3): 1276-1283, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27018370

RESUMO

PURPOSE: To use quantitative susceptibility mapping (QSM) to investigate changes in cartilage canals in the distal femur of juvenile goats after their surgical transection. METHODS: Chondronecrosis was surgically induced in the right medial femoral condyles of four 4-day-old goats. Both the operated and control knees were harvested at 2, 3, 5, and 10 weeks after the surgeries. Ex vivo MRI scans were conducted at 9.4 Tesla using TRAFF (relaxation time along a fictitious field)-weighted fast spin echo imaging and QSM to detect areas of chondronecrosis and investigate cartilage canal abnormalities. Histological sections from these same areas stained with hematoxylin and eosin and safranin O were evaluated to assess the affected tissues. RESULTS: Both the histological sections and the TRAFF -weighted images of the femoral condyles demonstrated focal areas of chondronecrosis, evidenced by pyknotic chondrocyte nuclei, loss of matrix staining, and altered MR image contrast. At increasing time points after surgery, progressive changes and eventual disappearance of abnormal cartilage canals were observed in areas of chondronecrosis by using QSM. CONCLUSION: Abnormal cartilage canals were directly visualized in areas of surgically induced chondronecrosis. Quantitative susceptibility mapping enabled investigation of the vascular changes accompanying chondronecrosis in juvenile goats. Magn Reson Med 77:1276-1283, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Doenças Assintomáticas , Cartilagem Articular/diagnóstico por imagem , Cartilagem Articular/patologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Osteocondrite Dissecante/diagnóstico , Osteocondrite Dissecante/patologia , Animais , Cabras , Aumento da Imagem/métodos , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA