Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
BJU Int ; 134(2): 201-206, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38343138

RESUMO

OBJECTIVE: To determine surgical outcomes and stone-free rates (SFRs) when offering upfront retrograde intrarenal surgery (RIRS) to patients with asymptomatic incidental renal stones (AIRS), as active surveillance, shockwave lithotripsy or upfront intervention in patients with AIRS is still a debate among urologists. PATIENTS AND METHODS: This retrospective FLEXible Ureteroscopy Outcomes Registry (FLEXOR), supported by the Team of Worldwide Endourological Researchers (TOWER), examines adult patients who underwent RIRS. We analysed a subset of asymptomatic patients with renal stones on imaging who were treated with RIRS. Data includes patient characteristics, stone specifications, anaesthesia type, perioperative details, complications, and SFR. A multivariable logistic regression analysis was performed to assess factors associated with the SFR. RESULTS: Among 679 patients with AIRS, 640 met the inclusion criteria. The median age was 55 years, with 33.4% being female. In all, 22.1% had positive urine cultures. The median stone diameter was 12 mm, commonly in lower and interpolar locations. RIRS was preferentially performed under general anaesthesia using a reusable scope in 443 cases. Prophylactic antibiotics were administered to 314 patients. The median operation time was 58 min and the median laser time was 24 min. The SFR was 68.8%. The use of holmium laser (odds ratio [OR] 0.21, 95% confidence interval [CI] 0.06-0.63; P < 0.01) and multiple stones (OR 0.38, 95% CI 0.19-0.76; P < 0.01) were factors associated with lower odds of being stone free. Overall complications were minimal, with sepsis in 1.6% of patients. Re-interventions were performed in 76 cases (11.8%), with RIRS being the most common in 67 cases (10.6%). CONCLUSION: Our multicentre real-world study is the first of its kind that highlights the pros and cons of offering RIRS to patients with AIRS and demonstrates a favourable SFR with acceptable complications. Pre-emptively discussing potential re-intervention helps patients make informed decisions, particularly in cases involving large and multiple stones.


Assuntos
Achados Incidentais , Cálculos Renais , Ureteroscopia , Humanos , Cálculos Renais/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ureteroscopia/efeitos adversos , Ureteroscopia/métodos , Idoso , Adulto , Resultado do Tratamento , Doenças Assintomáticas/terapia
2.
World J Urol ; 42(1): 413, 2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39012390

RESUMO

PURPOSE: The infundibulo-pelvic angle (IPA) is reportedly a predictor of successful ureteroscopy for lower pole renal stones, however there is uncertainty at which IPA success is likely. We therefore aimed to perform a meta-analysis and determine at which the angle of likely success and failure. METHODS: We performed a systematic review and meta-analysis as per Cochrane guidelines in accordance to the PRISMA statement. The review was registered with PROSPERO prior to commencement (ID: CRD42022296732). We included studies reporting on outcomes of ureteroscopy for lower pole stones, with IPA. We excluded patients undergoing alternative treatments for lower pole stones, anatomical abnormalities and studies with < 10 patients. We assessed bias with the Newcastle-Ottawa scale. We performed meta-analysis in R, and summarised the findings as per GRADE. RESULTS: Overall, there were 13 studies included, with 10 included for meta-analysis. These studies covered n = 1964 patients (71% stone free). Overall, the stone free patients had a significantly less acute mean IPA (52o ± 9o), compared to the non-stone free patients (39o ± 7o), on meta-analysis (REM MD = -13.0, 95% CI: -18.7 to -7.2, p < 0.001). On examination of forest plots, at IPA < 30o no patients were stone free, whilst > 50o all were stone free. Risk of bias was moderate, and certainty of evidence was 'very low'. CONCLUSION: With a very low certainty of evidence, we demonstrate that at an IPA of < 30o no patient is stone free, whilst > 50o all patients (in this review) are stone free. More evidence is therefore needed.


Assuntos
Cálculos Renais , Pelve Renal , Ureteroscopia , Humanos , Cálculos Renais/cirurgia , Cálculos Renais/terapia , Resultado do Tratamento
3.
World J Urol ; 42(1): 50, 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38244074

RESUMO

BACKGROUND: Accurate prediction of post-donor nephrectomy (DN) glomerular filtration rate is potentially useful for evaluating and counselling living kidney donors. Currently, there are limited tools to evaluate post-operative new-baseline glomerular filtration rate (NBGFR) in kidney donors. We aim to validate a conceptually simple formula based on split renal function (SRF) previously developed for radical nephrectomy patients. METHODS: Eighty-three consecutive patients who underwent DN from 2010 to 2016 were included. Pre-operative CT imaging and functional data including pre-DN baseline Global GFR (108.2 ± 13.2 mL/min/1.73m2) were included. Observed NBGFR was defined as the latest eGFR 3-12 months post-DN. SRF, defined as volume of the contralateral non-resected kidney normalised by total volume of kidneys, was determined from pre-operative cross-sectional imaging (49.2 ± 2.36%). The equation derived from Rathi et al. is as detailed: Predicted NBGFR = 1.24 × (Global GFR Pre-DN) x (SRF). RESULTS: The relationship between predicted NBGFR (66.0 ± 8.29 mL/min/1.73m2) and observed NBGFR (74.9 ± 16.4 mL/min/1.73m2) was assessed by evaluating correlation coefficients, bias, precision, accuracy, and concordance. The new SRF-based formula for NBGFR prediction correlated strongly with observed post-operative NBGFR (Pearson's r = 0.729) demonstrating minimal bias (median difference = 7.190 mL/min/1.73m2) with good accuracy (96.4% within ± 30%, 62.7% within ± 15%) and precision (IQR of bias = - 0.094 to 16.227). CONCLUSION: The SRF-based formula was also able to accurately discriminate all but one patient to an NBGFR of > 45 mL/min/1.73m2. We utilised the newly developed SRF-based formula for predicting NBGFR in a living kidney donor population. Counselling of donor post-operative renal outcomes may then be optimised pre-operatively.


Assuntos
Transplante de Rim , Humanos , Taxa de Filtração Glomerular , Estudos Retrospectivos , Rim/diagnóstico por imagem , Rim/cirurgia , Nefrectomia/métodos , Doadores Vivos
4.
World J Urol ; 42(1): 470, 2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39110254

RESUMO

BACKGROUND: We aimed to determine if preoperative prostate volume-enucleated weight concordance predicts short-term anatomical endoscopic enucleation of the prostate (AEEP) outcomes using the REAP international database. METHODS: 649 patients with data on both preoperative ultrasound-derived prostate volume and enucleated specimen weight were analyzed. Linear regression was used to investigate the effect of volume-weight concordance on postoperative outcomes. Model residuals were used to divide the cohort into 3 centiles: (1) less-than-expected enucleated specimen weight; (2) appropriate concordance between prostate volume and specimen weight; (3) more-than-expected specimen weight. Outcomes were also analyzed with only enucleated weight as a predictor (comparing ≤ 80 g and > 80 g). RESULTS: There was a trend towards more-than-expected enucleated specimen weight with increased age (p = 0.006). There was an increasing trend of operation time (p = 0.012) and enucleation time (p = 0.015) as specimen weight increased, and a decreasing trend of postoperative acute urinary retention (p = 0.005). Laser type, enucleation method, and early apical release were similar. In correlation analysis, greater-than-expected prostate weight was associated with greater Qmax improvement at 3 months. Prostate weight alone did not appear to be a significant predictor of outcomes. CONCLUSIONS: If enucleated specimen weight is more than expected according to preoperative ultrasound volume measurement, greater Qmax improvement and less postoperative acute urinary retention is expected. Although precision may be limited by ultrasound approximation and inexact specimen weight measurements, these shortcomings are similar in real-world clinical practice. Overall, preoperative prostate volume and actual enucleated specimen weight should be interpreted in the context of each other to predict clinical outcomes.


Assuntos
Bases de Dados Factuais , Endoscopia , Próstata , Hiperplasia Prostática , Humanos , Masculino , Tamanho do Órgão , Próstata/patologia , Próstata/cirurgia , Próstata/diagnóstico por imagem , Idoso , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/patologia , Pessoa de Meia-Idade , Resultado do Tratamento , Endoscopia/métodos , Período Pré-Operatório , Prostatectomia/métodos , Estudos Retrospectivos
5.
World J Urol ; 42(1): 318, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38743260

RESUMO

OBJECTIVE: Localized Upper Urinary Tract Urothelial Carcinoma (UTUC) is an uncommon cancer typically detected at an advanced stage. Currently, radical nephroureterectomy (RNU) with bladder cuff excision is the standard treatment for high-risk UTUC. This meta-analysis aims to evaluate the 5-year overall and cancer-specific survival and bladder recurrence rates in studies comparing endoscopic kidney-sparing surgeries (E-KSS) with RNU in localized UTUC. EVIDENCE ACQUISITION: We performed a literature search on 20th April 2023 through PubMed, Web of Science, and Scopus. The PICOS model was used for study inclusion: P: adult patients with localized UTUC; I: E-KSS. C: RNU; O: primary: overall survival (OS); secondary: cancer-specific survival (CSS), bladder recurrence rate, and metastasis-free survival (MFS). S: retrospective, prospective, and randomized studies. EVIDENCE SYNTHESIS: Overall, 11 studies involving 2284 patients were eligible for this meta-analysis, 737 in the E-KSS group and 1547 in the RNU group. E-KSS showed a similar overall 5-year OS between E-KSS and RNU, and for low-grade tumors, while 5-year OS favored RNU for high-grade tumors (RR 1.84, 95% CI 1.26-2.69, p = 0.002). No difference emerged for 5-year CSS between the two groups, even when the results were stratified for low- and high grade tumors. Bladder recurrence rate and 5-year MFS were also similar between the two groups. CONCLUSIONS: Our review showed that E-KSS is a viable option for patients with localized UTUC with non-inferior oncological outcomes as compared with RNU, except for 5-year OS in high-grade tumors which favoured RNU.


Assuntos
Carcinoma de Células de Transição , Neoplasias Renais , Nefroureterectomia , Neoplasias Ureterais , Humanos , Nefroureterectomia/métodos , Carcinoma de Células de Transição/cirurgia , Carcinoma de Células de Transição/patologia , Carcinoma de Células de Transição/mortalidade , Neoplasias Ureterais/cirurgia , Neoplasias Ureterais/mortalidade , Neoplasias Ureterais/patologia , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Neoplasias Renais/mortalidade , Ureteroscopia/métodos
6.
World J Urol ; 42(1): 355, 2024 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-38796790

RESUMO

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Assuntos
Desenho de Equipamento , Iluminação , Ureteroscópios , Ureteroscopia , Luz , Humanos , Solução Salina , Cor
7.
World J Urol ; 42(1): 294, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38704777

RESUMO

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Assuntos
Ureteroscópios , Ureteroscopia , Humanos , Desenho de Equipamento , Iluminação , Maleabilidade , Cálices Renais
8.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
9.
World J Urol ; 42(1): 299, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38710824

RESUMO

PURPOSE: The primary aim of the study was to evaluate if en-bloc vs. non en-bloc made a difference to intra-, peri- and post-operative surgical outcomes of anatomical endoscopic enucleation (AEEP) in large (> 80 cc) and very large prostates (> 200 cc). The secondary aim was to determine the influence of energy and instruments used. METHODS: Data of patients with > 80 cc prostate who underwent surgery between 2019 and 2022 were obtained from 16 surgeons across 13 centres in 9 countries. Propensity score matching (PSM) was used to reduce confounding. Logistic regression was performed to evaluate factors associated with postoperative urinary incontinence (UI). RESULTS: 2512 patients were included with 991 patients undergoing en-bloc and 1521 patients undergoing non-en-bloc. PSM resulted in 481 patients in both groups. Total operation time was longer in the en-bloc group (p < 0.001), enucleation time was longer in the non en-bloc group (p < 0.001) but morcellation times were similar (p = 0.054). Overall, 30 day complication rate was higher in the non en-bloc group (16.4% vs. 11.4%; p = 0.032). Rate of late complications (> 30 days) was similar (2.3% vs. 2.5%; p > 0.99). There were no differences in rates of UI between the two groups. Multivariate analysis revealed that age, Qmax, pre-operative, post-void residual urine (PVRU) and total operative time were predictors of UI. CONCLUSIONS: In experienced hands, AEEP in large prostates by the en-bloc technique yields a lower rate of complication and a slightly shorter operative time compared to the non en-bloc approach. However, it does not have an effect on rates of post-operative UI.


Assuntos
Complicações Pós-Operatórias , Pontuação de Propensão , Prostatectomia , Hiperplasia Prostática , Humanos , Masculino , Idoso , Prostatectomia/métodos , Hiperplasia Prostática/cirurgia , Pessoa de Meia-Idade , Resultado do Tratamento , Tamanho do Órgão , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Próstata/cirurgia , Próstata/patologia , Incontinência Urinária/epidemiologia
10.
World J Urol ; 42(1): 79, 2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38353743

RESUMO

PURPOSE: To identify laser settings and limits applied by experts during laser vaporization (vapBT) and laser en-bloc resection of bladder tumors (ERBT) and to identify preventive measures to reduce complications. METHODS: After a focused literature search to identify relevant questions, we conducted a survey (57 questions) which was sent to laser experts. The expert selection was based on clinical experience and scientific contribution. Participants were asked for used laser types, typical laser settings during specific scenarios, and preventive measures applied during surgery. Settings for a maximum of 2 different lasers for each scenario were possible. Responses and settings were compared among the reported laser types. RESULTS: Twenty-three of 29 (79.3%) invited experts completed the survey. Thulium fiber laser (TFL) is the most common laser (57%), followed by Holmium:Yttrium-Aluminium-Garnet (Ho:YAG) (48%), continuous wave (cw) Thulium:Yttrium-Aluminium-Garnet (Tm:YAG) (26%), and pulsed Tm:YAG (13%). Experts prefer ERBT (91.3%) to vapBT (8.7%); however, relevant limitations such as tumor size, number, and anatomical tumor location exist. Laser settings were generally comparable; however, we could find significant differences between the laser sources for lateral wall ERBT (p = 0.028) and standard ERBT (p = 0.033), with cwTm:YAG and pulsed Tm:YAG being operated in higher power modes when compared to TFL and Ho:YAG. Experts prefer long pulse modes for Ho:YAG and short pulse modes for TFL lasers. CONCLUSION: TFL seems to have replaced Ho:YAG and Tm:YAG. Most laser settings do not differ significantly among laser sources. For experts, continuous flow irrigation is the most commonly applied measure to reduce complications.


Assuntos
Alumínio , Túlio , Neoplasias da Bexiga Urinária , Ítrio , Humanos , Túlio/uso terapêutico , Neoplasias da Bexiga Urinária/cirurgia , Lasers , Tecnologia
11.
World J Urol ; 42(1): 180, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38507108

RESUMO

PURPOSE: To evaluate complications and urinary incontinence (UI) after endoscopic enucleation of the prostate (EEP) stratified by prostate volume (PV). METHODS: We retrospectively reviewed patients with benign prostatic hyperplasia who underwent EEP with different energy sources in 14 centers (January 2019-January 2023). INCLUSION CRITERIA: prostate volume ≥ 80 ml. EXCLUSION CRITERIA: prostate cancer, previous prostate/urethral surgery, pelvic radiotherapy. PRIMARY OUTCOME: complication rate. SECONDARY OUTCOMES: incidence of and factors affecting postoperative UI. Patients were divided into 3 groups. Group 1: PV = 80-100 ml; Group 2 PV = 101-200 ml; Group 3 PV > 200 ml. Multivariable logistic regression analysis was performed to evaluate independent predictors of overall incontinence. RESULTS: There were 486 patients in Group 1, 1830 in Group 2, and 196 in Group 3. The most commonly used energy was high-power Holmium laser followed by Thulium fiber laser in all groups. Enucleation, morcellation, and total surgical time were significantly longer in Group 2. There was no significant difference in overall 30-day complications and readmission rates. Incontinence incidence was similar (12.1% in Group 1 vs. 13.2% in Group 2 vs. 11.7% in Group 3, p = 0.72). The rate of stress and mixed incontinence was higher in Group 1. Multivariable regression analysis showed that age (OR 1.019 95% CI 1.003-1.035) was the only factor significantly associated with higher odds of incontinence. CONCLUSIONS: PV has no influence on complication and UI rates following EEP. Age is risk factor of postoperative UI.


Assuntos
Terapia a Laser , Lasers de Estado Sólido , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Incontinência Urinária , Masculino , Humanos , Próstata/cirurgia , Estudos Retrospectivos , Incidência , Terapia a Laser/métodos , Incontinência Urinária/epidemiologia , Incontinência Urinária/etiologia , Incontinência Urinária/cirurgia , Hiperplasia Prostática/cirurgia , Hiperplasia Prostática/complicações , Ressecção Transuretral da Próstata/efeitos adversos , Ressecção Transuretral da Próstata/métodos , Lasers de Estado Sólido/efeitos adversos , Resultado do Tratamento
12.
Curr Opin Urol ; 34(2): 98-104, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962176

RESUMO

PURPOSE OF REVIEW: ChatGPT has emerged as a potentially useful tool for healthcare. Its role in urology is in its infancy and has much potential for research, clinical practice and for patient assistance. With this narrative review, we want to draw a picture of what is known about ChatGPT's integration in urology, alongside future promises and challenges. RECENT FINDINGS: The use of ChatGPT can ease the administrative work, helping urologists with note-taking and clinical documentation such as discharge summaries and clinical notes. It can improve patient engagement through increasing awareness and facilitating communication, as it has especially been investigated for uro-oncological diseases. Its ability to understand human emotions makes ChatGPT an empathic and thoughtful interactive tool or source for urological patients and their relatives. Currently, its role in clinical diagnosis and treatment decisions is uncertain, as concerns have been raised about misinterpretation, hallucination and out-of-date information. Moreover, a mandatory regulatory process for ChatGPT in urology is yet to be established. SUMMARY: ChatGPT has the potential to contribute to precision medicine and tailored practice by its quick, structured responses. However, this will depend on how well information can be obtained by seeking appropriate responses and asking the pertinent questions. The key lies in being able to validate the responses, regulating the information shared and avoiding misuse of the same to protect the data and patient privacy. Its successful integration into mainstream urology needs educational bodies to provide guidelines or best practice recommendations for the same.


Assuntos
Urologia , Humanos , Inteligência Artificial , Assistência ao Paciente , Urologistas , Participação do Paciente
13.
Curr Opin Urol ; 34(2): 110-115, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37962372

RESUMO

PURPOSE OF REVIEW: Flexible ureteroscopy (fURS) has evolved into both diagnostic and therapeutic modalities. Our review discusses the cost-effectiveness of single use flexible ureteroscopes (su-fURS) and the use of these instruments in routine urological practice. RECENT FINDINGS: There are studies which support the use of su-fURS with an argument of both cost and clinical utility over reusable flexible ureteroscopes (ru-fURS). However, the cost may vary across countries, hence is difficult to compare the results based on the current literature. Perhaps therefore there is a role for hybrid strategy incorporating ru- and su-fURS, where su-fURS are employed in complex endourological cases with a high risk of scope damage or fracture to preserve ru-fURS, with the ability to maintain clinical activity in such an event. SUMMARY: While there seems to be some cost advantages with su-fURS with reduced sterilization and maintenance costs, the data supporting it is sparse and limited. This choice of scope would depend on the durability of ru-fURS, procedural volumes, limited availability of sterilization units in some centers and potential risk of infectious complications. It is time that cost-benefit analysis is conducted with defined outcomes for a given healthcare set-up to help with the decision making on the type of scope that best serves their needs.


Assuntos
Cálculos Renais , Ureteroscópios , Humanos , Ureteroscopia/métodos , Análise de Custo-Efetividade , Análise Custo-Benefício , Cálculos Renais/terapia
14.
Neurourol Urodyn ; 43(1): 126-143, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38010924

RESUMO

INTRODUCTION: Men with detrusor underactivity (DUA) and concomitant bladder outlet obstruction (BOO) due to benign prostatic enlargement (BPE) may present poorer functional outcomes after surgical desobstruction. This study aimed to evaluate the safety and efficacy of BPE surgery in men with DUA compared with those with normal detrusor contractility (NC). MATERIALS AND METHODS: This review was performed according to the 2020 PRISMA framework. A comprehensive literature search was performed until May 7, 2023, using MEDLINE, EMBASE, and Cochrane Database. No date limits were imposed. Only comparative studies were accepted. The primary endpoint was to assess if there was any difference in short- and long-term functional outcomes after BPE surgery in men with DUA and NC. The secondary endpoint was to evaluate the differences in perioperative outcomes and postoperative complications between the two groups. Meta-analysis was performed using Review Manager (RevMan) software. RESULTS: There were 5 prospective nonrandomized studies and 12 retrospective studies, including 1701 DUA and 1993 NC patients. Regarding surgical procedures, there were eight TURP (transurethral resection of the prostate) studies, four GreenLight PVP (photoselective vaporization of the prostate) studies, two HoLEP (Holmium laser enucleation of the prostate) studies, one GreenLight PVP/HoLEP study, one Holmium laser incision of the prostate study, and one study did not report the type of surgery. We did not find a statistically significant difference between the two groups in terms of perioperative outcomes, including postoperative catheterization time, hospitalization time, urinary retention, need to recatheterization, transfusion rate, or urinary tract infections. Also, we found no significant differences in long-term complications, such as bladder neck stenosis or urethral stenosis. Posttreatment bladder recatheterization and retreatment rate for BPE regrowth could not be evaluated properly, because only one study reported these findings. When we analyzed functional outcomes at 3 months, those with NC had lower International Prostatic Symptom Score (IPSS), lower quality-of-life (QoL) score, better maximum flow rate (Qmax), and lower post-voiding residual (PVR) of urine. These results were maintained at 6 months postoperatively, with exception of PVR that showed no difference. However, at 12 and more than 12 months the functional outcomes became similar regarding IPSS and QoL. There were few data about Qmax and PVR at longer follow-up. CONCLUSION: In this meta-analysis, data suggest that BOO surgical treatment in patients with concomitant BPE and DUA appears to be safe. Despite patients with DUA may present worse functional outcomes in the short postoperative term compared with the NC population, IPSS and QoL scores become comparable again after a longer follow-up period after surgery.


Assuntos
Terapia a Laser , Hiperplasia Prostática , Ressecção Transuretral da Próstata , Obstrução do Colo da Bexiga Urinária , Bexiga Inativa , Masculino , Humanos , Ressecção Transuretral da Próstata/efeitos adversos , Bexiga Inativa/complicações , Bexiga Inativa/cirurgia , Qualidade de Vida , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Hiperplasia Prostática/complicações , Hiperplasia Prostática/cirurgia , Obstrução do Colo da Bexiga Urinária/etiologia , Obstrução do Colo da Bexiga Urinária/cirurgia , Terapia a Laser/métodos
15.
Int Braz J Urol ; 50(4): 459-469, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38743064

RESUMO

PURPOSE: To assess the incidence of the most common intra- and early postoperative complications following RIRS in a large series of patients with kidney stones. METHODS: We conducted a retrospective analysis of patients with kidney stones who underwent RIRS across 21 centers from January 2018 to August 2021, as part of the Global Multicenter Flexible Ureteroscopy Outcome (FLEXOR) Registry. RESULTS: Among 6669 patients undergoing RIRS, 4.5% experienced intraoperative pelvicalyceal system bleeding without necessitating blood transfusion. Only 0.1% of patients, required a blood transfusion. The second most frequent intraoperative complication was ureteric injury due to the ureteral access sheath requiring stenting (1.8% of patients). Postoperatively, the most prevalent early complications were fever/infections requiring antibiotics (6.3%), blood transfusions (5.5%), and sepsis necessitating intensive care unit admission (1.3%). In cases of ureteric injury, a notably higher percentage of patients exhibited multiple stones and stone(s) in the lower pole, and these cases were correlated with prolonged lasing and overall surgical time. Hematuria requiring a blood transfusion was associated with an increased prevalence of larger median maximum stone diameters, particularly among patients with stones exceeding 20 mm. Furthermore, these cases exhibited a significant prolongation in surgical time. Sepsis necessitating admission to the intensive care unit was more prevalent among the elderly, concomitant with a significantly larger median maximum stone diameter. CONCLUSIONS: Our analysis showed that RIRS has a good safety profile but bleeding requiring transfusions, ureteric injury, fever, and sepsis are still the most common complications despite advancements in technology.


Assuntos
Cálculos Renais , Complicações Pós-Operatórias , Sistema de Registros , Ureteroscopia , Humanos , Ureteroscopia/efeitos adversos , Ureteroscopia/métodos , Estudos Retrospectivos , Feminino , Cálculos Renais/cirurgia , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Idoso , Adulto , Resultado do Tratamento
16.
Ann Surg ; 277(1): 50-56, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33491983

RESUMO

OBJECTIVE: To assess the degree of psychological impact among surgical providers during the COVID-19 pandemic. SUMMARY OF BACKGROUND DATA: The COVID-19 pandemic has extensively impacted global healthcare systems. We hypothesized that the degree of psychological impact would be higher for surgical providers deployed for COVID-19 work, certain surgical specialties, and for those who knew of someone diagnosed with, or who died, of COVID-19. METHODS: We conducted a global web-based survey to investigate the psychological impact of COVID-19. The primary outcomes were the depression anxiety stress scale-21 and Impact of Event Scale-Revised scores. RESULTS: A total of 4283 participants from 101 countries responded. 32.8%, 30.8%, 25.9%, and 24.0% screened positive for depression, anxiety, stress, and PTSD respectively. Respondents who knew someone who died of COVID-19 were more likely to screen positive for depression, anxiety, stress, and PTSD (OR 1.3, 1.6, 1.4, 1.7 respectively, all P < 0.05). Respondents who knew of someone diagnosed with COVID-19 were more likely to screen positive for depression, stress, and PTSD (OR 1.2, 1.2, and 1.3 respectively, all P < 0.05). Surgical specialties that operated in the head and neck region had higher psychological distress among its surgeons. Deployment for COVID- 19-related work was not associated with increased psychological distress. CONCLUSIONS: The COVID-19 pandemic may have a mental health legacy outlasting its course. The long-term impact of this ongoing traumatic event underscores the importance of longitudinal mental health care for healthcare personnel, with particular attention to those who know of someone diagnosed with, or who died of COVID-19.


Assuntos
COVID-19 , Cirurgiões , Humanos , Saúde Mental , SARS-CoV-2 , Pandemias , Depressão/psicologia , Ansiedade/psicologia , Pessoal de Saúde/psicologia , Inquéritos e Questionários , Estresse Psicológico/psicologia
17.
J Urol ; 210(2): 323-330, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37126223

RESUMO

PURPOSE: We evaluated stone-free rate and complications after flexible ureteroscopy for renal stones, comparing thulium fiber laser and holmium:YAG laser with MOSES technology. MATERIALS AND METHODS: Data from adults who underwent flexible ureteroscopy in 20 centers worldwide were retrospectively reviewed (January 2018-August 2021). Patients with ureteral stones, concomitant bilateral procedures, and combined procedures were excluded. One-to-one propensity score matching for age, gender, and stone characteristics was performed. Stone-free rate was defined as absence of fragments >2 mm on imaging within 3 months after surgery. Multivariable logistic regression analysis was performed to evaluate independent predictors of being stone-free. RESULTS: Of 2,075 included patients, holmium:YAG laser with MOSES technology was used in 508 patients and thulium fiber laser in 1,567 patients. After matching, 284 patients from each group with comparable baseline characteristics were included. Pure dusting was applied in 6.0% of cases in holmium:YAG laser with MOSES technology compared with 26% in thulium fiber laser. There was a higher rate of basket extraction in holmium:YAG laser with MOSES technology (89% vs 43%, P < .001). Total operation time and lasing time were similar. Nine patients had sepsis in thulium fiber laser vs none in holmium:YAG laser with MOSES technology (P = .007). Higher stone-free rate was achieved in thulium fiber laser (85% vs 56%, P < .001). At multivariable analysis, the use of thulium fiber laser and ureteral access sheath ≥8F had significantly higher odds of being stone-free. Lasing time, multiple stones, stone diameter, and use of disposable scopes showed significantly lower odds of being stone-free. CONCLUSIONS: This real-world study favors the use of thulium fiber laser over holmium:YAG laser with MOSES technology in flexible ureteroscopy for renal stones by way of its higher single-stage stone-free rate.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Adulto , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/métodos , Túlio , Hólmio , Lasers de Estado Sólido/uso terapêutico , Ureteroscopia/métodos , Estudos Retrospectivos , Pontuação de Propensão , Cálculos Renais/cirurgia , Tecnologia , Sistema de Registros
18.
World J Urol ; 41(11): 3345-3353, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37728745

RESUMO

PURPOSE: Flexible ureteroscopy (fURS) is steadily gaining popularity in the management of renal calculi, including those located in the lower pole (LP). Due to difficulty in accessing to the LP of kidney in minority of cases with fURS and reports of lower stone-free rate (SFR), it is still considered as a challenge in selected cases. The purpose of the review was to analyze the various aspects of fURS for LP stones. METHODS: An extensive review of the recent literature was done including different factors such as anatomy, preoperative stenting, stone size, flexible scopes, types of lasers, laser fibers, suction, relocation, stone-free rates, and complications. RESULTS: The significance of various lower pole anatomical measurements remain a subject of debate and requires standardization. Recent improvements in fURS such as single-use digital scopes with better vision and flexibility, high power laser, thulium fiber laser, smaller laser fiber, and accessories have significantly contributed to make flexible ureteroscopy  more effective and safer in the management of LP stone. The utilization of thulium fiber lasers in conjunction with various suction devices is being recognized and can significantly improve SFR. CONCLUSIONS: With the significant advancement of various aspects of fURS, this treatment modality has shown remarkable efficacy and gaining widespread acceptance in management of LP kidney stones. These developments have made the fURS of LP stones less challenging.


Assuntos
Cálculos Renais , Ureteroscopia , Humanos , Túlio , Ureteroscópios , Cálculos Renais/cirurgia , Rim , Resultado do Tratamento
19.
World J Urol ; 41(11): 2889-2896, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37243718

RESUMO

PURPOSE: To assess the safety and effectiveness of magnetic ureteric stent removal with a special magnet retriever under ultrasound guidance. METHODS: A total of 60 male patients, who underwent ureteroscopy from October 2020 to March 2022, were prospectively enrolled and randomized into two groups. Group A patients underwent conventional double-J (DJ) stent insertion and subsequent stent removal via flexible cystoscopy. Group B patients underwent stent insertion using magnetic ureteric stent [Blackstar, Urotech (Achenmühle, Germany)] and stents were removed using a special magnet retriever under ultrasound guidance. Stents were left in situ for 30 days in both groups. All patients had follow-ups with a ureter stent symptoms questionnaire at 3- and 30-days post stent insertion. Visual analog scale (VAS) was assessed immediately after stent removal. RESULTS: Stent removal time (142.5 s vs 142.5 s, group A vs group B, p < 0.0001) and VAS scores (4 vs 1, group A vs group B, p = 0.0008) were significantly lower in Group B. There were no statistically significant differences between both groups in the "urinary symptoms" (p = 0.3471) and "sexual matters" (p = 0.6126) in the USSQ domains. There was marginal statistical significance favoring Group A in the "body pain" (p = 0.0303), "general health score" (p = 0.0072), "additional problems" (p = 0.0142), and "work performance" (p < 0.0001) domains. CONCLUSIONS: Magnetic ureteric stent can be considered as a safe and efficient alternative to conventional DJ stent. This approach avoids the need for cystoscopy, saving resources while minimizing patient discomfort.


Assuntos
Ureter , Humanos , Masculino , Ureter/cirurgia , Ureteroscopia , Dor/etiologia , Stents , Fenômenos Magnéticos
20.
World J Urol ; 41(5): 1243-1250, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36645461

RESUMO

PURPOSE: Hypocitraturia is a low urinary excretion of citrate and a well-known risk factor for kidney stone development in children. This systematic review aimed to evaluate the dietary management of hypocitraturia in children with urolithiasis. METHODS: Literature search was performed on 30th September 2022 using Embase, PubMed, and Cochrane Central Controlled Register of Trials. Studies were included if children with stones and hypocitraturia were managed with diet supplements. RESULTS: Six papers were included. Four studies evaluated the role of oral potassium citrate associated with high fluid intake on stone resolution and recurrence. Two studies assessed the impact of oral potassium citrate on long-term stone recurrence after percutaneous nephrolithotomy and shock wave lithotripsy. All studies demonstrated that the association of potassium citrate and high fluid intake was well tolerated with no side effects and restored normal urine citrate excretion, allowed a reduction in stone size, and, following definitive treatments, was associated with a lower rate of stone regrowth and recurrence compared with controls. These effects were demonstrated across all pediatric ages. CONCLUSIONS: Our review infers that oral potassium citrate and high fluid assumption are safe and effective in restoring urine citrate excretion, treating and preventing stone recurrence with no serious adverse events, and should probably be the first-line treatment of pediatric patients with asymptomatic stones and hypocitraturia.


Assuntos
Cálculos Renais , Urolitíase , Criança , Humanos , Citrato de Potássio/uso terapêutico , Urolitíase/tratamento farmacológico , Cálculos Renais/urina , Ácido Cítrico/uso terapêutico , Ácido Cítrico/urina , Citratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA