Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BJU Int ; 124(2): 297-301, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30714285

RESUMO

OBJECTIVES: To assess the accuracy of multiparametric magnetic resonance imaging (mpMRI) for the detection of significant prostate cancer in men undergoing radical prostatectomy (RP) in an Australian multicentre setting, and to assess concordance between mpMRI and RP for local tumour staging and index lesion locations. PATIENTS AND METHODS: Men who underwent mpMRI within 12 months of RP between January 2013 and August 2016 at three Australian sites were included (Central Coast, NSW, St Vincents Hospital, Melbourne, Vic., and Bendigo Hospital, Vic.). The results of mpMRI were compared with the final RP specimen to analyse the performance of mpMRI for significant prostate cancer detection, index lesion localization, prediction of T3 disease and lymph node metastasis. A comparison between mpMRI cases performed using the technical and reporting specifications of Prostate Imaging Reporting and Data System (PI-RADS) version 1 and version 2 was also performed. Data analysis was performed using spss 24.0. RESULTS: A total of 235 cases were included for analysis. mpMRI PI-RADS score ≥3 had a 91% sensitivity and 95% positive predictive value (PPV) for significant prostate cancer at RP. The overall concordance between index lesion location on mpMRI and RP specimen was 75%. The sensitivity for predication of significant prostate cancer was higher in the PI-RADS version 2 cases compared with PI-RADS version 1 (87-99%; P = 0.005). Index lesion concordance was higher in the PI-RADS version 2 group (68% vs 91%; P = 0.002). mpMRI had a 38% sensitivity, 95% specificity, 90% PPV and 57% negative predictive value for extraprostatic disease. Sensitivity for prediction of T3 disease improved from 30% to 62% (P = 0.008) with PI-RADS version 2. CONCLUSIONS: In patients undergoing RP, an abnormal mpMRI is highly predictive (95% PPV) of significant prostate cancer, with an index lesion concordance of 75%. There has been a significant improvement in accuracy after the adoption of PI-RADS version 2 technical specifications and reporting criteria; however; further study is required to determine if this is attributable to improved experience with mpMRI or changes in the PI-RADS system.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Austrália , Estudos de Coortes , Humanos , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Prostatectomia , Neoplasias da Próstata/cirurgia
2.
J Med Imaging Radiat Oncol ; 65(1): 79-81, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32978899

RESUMO

Duodenal volvulus is an extremely rare condition, with few cases reported in the literature. We present the case of an 83-year-old man with spontaneous duodenal volvulus diagnosed on CT imaging. Findings included volvulus of the third part of the duodenum, the chjmirocteristic whirl pattern of the superior mesenteric vessels and medialisation of the gallbladder. He was treated with nasogastric tube decompression and follow-up CT demonstrated complete resolution of the volvulus.


Assuntos
Volvo Intestinal , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Diagnóstico por Imagem , Humanos , Volvo Intestinal/diagnóstico por imagem , Volvo Intestinal/cirurgia , Masculino
3.
BJUI Compass ; 2(6): 377-384, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35474704

RESUMO

Objectives: To investigate the utility of Magnetic Resonance Imaging (MRI) for prostate cancer diagnosis in the Australian setting. Patients and methods: All consecutive men who underwent a prostate biopsy (transperineal or transrectal) at Royal Melbourne Hospital between July 2017 to June 2019 were included, totalling 332 patients. Data were retrospectively collected from patient records. For each individual patient, the risk of prostate cancer diagnosis at biopsy based on clinical findings was determined using the European Randomized study of Screening for Prostate Cancer (ERSPC) risk calculator, with and without incorporation of MRI findings. Results: MRI has good diagnostic accuracy for clinically significant prostate cancer. A PI-RADS 2 or lower finding has a negative predictive value of 96% for clinically significant cancer, and a PI-RADS 3, 4 or 5 MRI scan has a sensitivity of 93%. However, MRI has a false negative rate of 6.5% overall for clinically significant prostate cancers. Pre- biopsy MRI may reduce the number of unnecessary biopsies, as up to 50.0% of negative or ISUP1 biopsies have MRI PI-RADS 2 or lower. Incorporation of MRI findings into the ERSPC calculator improved predictive performance for all prostate cancer diagnoses (AUC 0.77 vs 0.71, P = .04), but not for clinically significant cancer (AUC 0.89 vs 0.87, P = .37). Conclusion: MRI has good sensitivity and negative predictive value for clinically significant prostate cancers. It is useful as a pre-biopsy tool and can be used to significantly reduce the number of unnecessary prostate biopsies. However, MRI does not significantly improve risk predictions for clinically significant cancers when incorporated into the ERSPC risk calculator.

4.
ANZ J Surg ; 90(10): 1857-1862, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32808418

RESUMO

BACKGROUND: The aim of this study was to identify the current evidence regarding the risk of acquiring viral infections from gases or plumes during intra-abdominal surgery. Peritoneal fluids may contain cellular material and virus particles. Electrocautery smoke and plumes from energy devices may aerosolize harmful substances and viral particles. Insufflation and desufflation during laparoscopic surgery may also aerosolize and distribute biological material. A systematic scoping review was performed to assess the evidence and inform safe surgical practice. METHODS: A systematic search of the PubMed and Medline databases was undertaken until June 2020, observing Preferred Reporting Items for Systematic Reviews and Meta-Analyses methodology, to identify articles associating viral infection of operating room staff from surgical gases and plumes. All evidence levels were included. The search strategy utilized the search terms 'surgery', 'laparoscopy', 'laparoscopic' 'virus', 'smoke', 'risk', 'infection'. RESULTS: The literature search identified 74 articles. Eight articles relevant to the subject of this review were included in the analysis, two of which specifically related to intra-abdominal surgery. Of the remaining six, four involved gynaecological surgery and two were in-vitro studies. No evidence that intra-abdominal surgery was associated with an increased risk of acquiring viral infections from exsufflated gas or smoke plumes was identified. CONCLUSION: There is currently no evidence that respiratory viruses can be found in the peritoneal fluid. Whilst there is currently no evidence that desufflated carbon dioxide or surgical smoke plumes present a significant infectious risk, there is not a wealth of literature to inform current practice. Further clinical research in this area is required.


Assuntos
Insuflação , Laparoscopia , Viroses , Feminino , Gases , Procedimentos Cirúrgicos em Ginecologia , Humanos , Insuflação/efeitos adversos , Viroses/epidemiologia , Viroses/etiologia
5.
Eur Urol Open Sci ; 20: 28-36, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34337456

RESUMO

BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) has shown promise to improve detection of prostate cancer over conventional methods. However, most studies do not describe whether the location of mpMRI lesions match that of cancer found at biopsy, which may lead to an overestimation of accuracy. OBJECTIVE: To quantitate the effect of mapping locations of mpMRI lesions to locations of positive biopsy cores on the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of mpMRI. DESIGN SETTING AND PARTICIPANT: We retrospectively identified patients having mpMRI of the prostate preceding prostate biopsy at three centres from 2013 to 2016. Men with targetable lesions on imaging underwent directed biopsy in addition to systematic biopsy. We correlated locations of positive mpMRI lesions with those of positive biopsy cores, defining a match when both were in the same sector of the prostate. We defined positive mpMRI as Prostate Imaging Reporting and Data System (PI-RADS) score ≥4 and significant cancer at biopsy as grade group ≥2. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Sensitivity, specificity, PPV, and NPV were calculated with and without location matching. RESULTS AND LIMITATIONS: Of 446 patients, 247 (55.4%) had positive mpMRI and 232 (52.0%) had significant cancer at biopsy. Sensitivity and NPV for detecting significant cancer with location matching (both 63.4%) were decreased compared with those without location matching (77.6% and 73.9%, respectively). Of the 85 significant cancers not detected by mpMRI, most were of grade group 2 (64.7%, 55/85). CONCLUSIONS: We report a 10-15% decrease in sensitivity and NPV when location matching was used to detect significant prostate cancer by mpMRI. False negative mpMRI remains an issue, highlighting the continued need for biopsy and for improving the standards around imaging quality and reporting. PATIENT SUMMARY: The true accuracy of multiparametric magnetic resonance imaging (mpMRI) must be determined to interpret results and better counsel patients. We mapped the location of positive mpMRI lesions to where cancer was found at biopsy and found, when compared with matching to cancer anywhere in the prostate, that the accuracy of mpMRI decreased by 10-15%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA