Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 156
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Am J Gastroenterol ; 119(3): 438-449, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38857483

RESUMO

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high healthcare utilization and costs. Radiologic techniques including computed tomography angiography, catheter angiography, computed tomography enterography, magnetic resonance enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided.


Assuntos
Hemorragia Gastrointestinal , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/diagnóstico , Consenso , Estados Unidos , Gastroenterologia/normas , Sociedades Médicas , Diagnóstico por Imagem/métodos , Diagnóstico por Imagem/normas , Endoscopia Gastrointestinal
2.
Radiology ; 310(3): e232298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38441091

RESUMO

Gastrointestinal (GI) bleeding is the most common GI diagnosis leading to hospitalization within the United States. Prompt diagnosis and treatment of GI bleeding is critical to improving patient outcomes and reducing high health care utilization and costs. Radiologic techniques including CT angiography, catheter angiography, CT enterography, MR enterography, nuclear medicine red blood cell scan, and technetium-99m pertechnetate scintigraphy (Meckel scan) are frequently used to evaluate patients with GI bleeding and are complementary to GI endoscopy. However, multiple management guidelines exist, which differ in the recommended utilization of these radiologic examinations. This variability can lead to confusion as to how these tests should be used in the evaluation of GI bleeding. In this document, a panel of experts from the American College of Gastroenterology and Society of Abdominal Radiology provide a review of the radiologic examinations used to evaluate for GI bleeding including nomenclature, technique, performance, advantages, and limitations. A comparison of advantages and limitations relative to endoscopic examinations is also included. Finally, consensus statements and recommendations on technical parameters and utilization of radiologic techniques for GI bleeding are provided. © Radiological Society of North America and the American College of Gastroenterology, 2024. Supplemental material is available for this article. This article is being published concurrently in American Journal of Gastroenterology and Radiology. The articles are identical except for minor stylistic and spelling differences in keeping with each journal's style. Citations from either journal can be used when citing this article. See also the editorial by Lockhart in this issue.


Assuntos
Hemorragia Gastrointestinal , Radiologia , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia , Catéteres
3.
Magn Reson Med ; 91(6): 2459-2482, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38282270

RESUMO

PURPOSE: To develop and evaluate methods for (1) reconstructing 3D-quantification using an interleaved Look-Locker acquisition sequence with T2 preparation pulse (3D-QALAS) time-series images using a low-rank subspace method, which enables accurate and rapid T1 and T2 mapping, and (2) improving the fidelity of subspace QALAS by combining scan-specific deep-learning-based reconstruction and subspace modeling. THEORY AND METHODS: A low-rank subspace method for 3D-QALAS (i.e., subspace QALAS) and zero-shot deep-learning subspace method (i.e., Zero-DeepSub) were proposed for rapid and high fidelity T1 and T2 mapping and time-resolved imaging using 3D-QALAS. Using an ISMRM/NIST system phantom, the accuracy and reproducibility of the T1 and T2 maps estimated using the proposed methods were evaluated by comparing them with reference techniques. The reconstruction performance of the proposed subspace QALAS using Zero-DeepSub was evaluated in vivo and compared with conventional QALAS at high reduction factors of up to nine-fold. RESULTS: Phantom experiments showed that subspace QALAS had good linearity with respect to the reference methods while reducing biases and improving precision compared to conventional QALAS, especially for T2 maps. Moreover, in vivo results demonstrated that subspace QALAS had better g-factor maps and could reduce voxel blurring, noise, and artifacts compared to conventional QALAS and showed robust performance at up to nine-fold acceleration with Zero-DeepSub, which enabled whole-brain T1, T2, and PD mapping at 1 mm isotropic resolution within 2 min of scan time. CONCLUSION: The proposed subspace QALAS along with Zero-DeepSub enabled high fidelity and rapid whole-brain multiparametric quantification and time-resolved imaging.


Assuntos
Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética Multiparamétrica , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas
4.
Pediatr Radiol ; 54(2): 239-249, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38112762

RESUMO

BACKGROUND: Improving access to magnetic resonance imaging (MRI) in childhood can be facilitated by making it faster and cheaper and reducing need for sedation or general anesthesia (GA) to mitigate motion. Some children achieve diagnostic quality MRI without GA through the use of non- practices fostering their cooperation and/or alleviating anxiety. Employed before and during MRI, these variably educate, distract, and/or desensitize patients to this environment. OBJECTIVE: To assess current utilization of non-sedate practices in pediatric MRI, including variations in practice and outcomes. MATERIALS AND METHODS: A survey-based study was conducted with 1372 surveys emailed to the Society for Pediatric Radiology members in February 2021, inviting one response per institution. RESULTS: Responses from 50 unique institutions in nine countries revealed 49/50 (98%) sites used ≥ 1 non-sedate practice, 48/50 (96%) sites in infants < 6 months, and 11/50 (22%) for children aged 6 months to 3 years. Non-sedate practices per site averaged 4.5 (range 0-10), feed and swaddle used at 47/49 (96%) sites, and child life specialists at 35/49 (71%). Average success rates were moderate (> 50-75%) across all sites and high (> 75-100%) for 20% of sites, varying with specific techniques. Commonest barriers to use were scheduling conflicts and limited knowledge. CONCLUSION: Non-sedate practice utilization in pediatric MRI was near-universal but widely variable across sites, ages, and locales, with room for broader adoption. Although on average non-sedate practice success rates were similar, the range in use and outcomes suggest a need for standardized implementation guidelines, including patient selection and outcome metrics, to optimize utilization and inform educational initiatives.


Assuntos
Anestesia Geral , Imageamento por Ressonância Magnética , Lactente , Criança , Humanos , Movimento (Física) , Imageamento por Ressonância Magnética/métodos , Inquéritos e Questionários , Exame Físico
5.
Eur Radiol ; 33(2): 1318-1328, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36074261

RESUMO

OBJECTIVES: To assess the impact of dual-energy CT (DECT) utilization in practice by measuring the readers' confidence, the need for additional image requests, and diagnostic performance in renal lesion assessment, compared to single-energy CT (SECT) using contrast-enhanced MRI to establish the reference standard. MATERIALS AND METHODS: Sixty-nine patients (M/F = 47/22) who underwent a dual-phase renal SECT (n = 34) or DECT (n = 35) and had a contrast-enhanced MRI within 180 days were retrospectively collected. Three radiologists assessed images on different sessions (SECT, DECT, and MRI) for (1) likely diagnosis (enhancing/non-enhancing); (2) diagnostic confidence (5-point Likert scale); (3) need for additional imaging test (yes/no); and (4) need for follow-up imaging (yes/no). Diagnostic accuracy was compared using AUC; p value < 0.05 was considered significant. RESULTS: One hundred fifty-six lesions consisting of 18% enhancing (n = 28/156, mean size: 30.37 mm, range: 9.9-94 mm) and 82% non-enhancing (n = 128/156, mean size: 23.91 mm, range: 5.0-94.2 mm) were included. The confidence level was significantly lower for SECT than their MRI (4.50 vs. 4.80, p value < 0.05) but not significantly different for DECT and the corresponding MRI (4.78 vs. 4.78, p > 0.05). There were significantly more requests for additional imaging in the SECT session than the corresponding MRI (20% vs. 4%), which was not significantly different between DECT and their MRI counterpart session (5.7% vs. 4.9%). Inter-reader agreement was almost perfect for DECT and MRI (kappa: 0.8-1) and substantial in SECT sessions (kappa: 0.6-0.8) with comparable diagnostic accuracy between SECT, DECT, and MRI (p value > 0.05). CONCLUSION: Single-phase DECT allows confident and reproducible characterization of renal masses with fewer recommendation for additional and follow-up imaging tests than dual-phase SECT and a performance similar to MRI. KEY POINTS: • DECT utilization leads to similar additional image requests to MRI (5.7% vs. 4.9%, p value > 0.05), whereas single-energy CT utilization leads to significantly higher image requests (20% vs. 4%, p value < 0.05). • DECT and MRI utilization bring highly reproducible results with almost perfect inter-reader agreement (kappa: 0.8-1), better than the inter-reader agreement in SECT utilization (kappa: 0.6-0.8). • Readers' confidence was not significantly altered between DECT and their MRI readout session (p value > 0.05). In contrast, confidence in the diagnosis was significantly lower in the SECT session than their MRI readout (p value < 0.05).


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos , Doses de Radiação , Imageamento por Ressonância Magnética
6.
Radiographics ; 43(6): e220192, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37167088

RESUMO

Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyperattenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. ©RSNA, 2023 Quiz questions for this article are available through the Online Learning Center.


Assuntos
Hemorragia Gastrointestinal , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Humanos , Hemorragia Gastrointestinal/diagnóstico por imagem , Intestino Delgado , Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos
7.
Pediatr Nephrol ; 38(10): 3253-3264, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36445479

RESUMO

Tuberous sclerosis complex (TSC) is an autosomal dominant disorder with an estimated incidence of one in 5000 to 10,000 live births worldwide. Two million people of all races and genders are estimated to have TSC secondary to mutations in one of two tumor suppressor genes, TSC1 or TSC2. The respective TSC1 and 2 gene products - hamartin and tuberin - form cytoplasmic heterodimers that inhibit mTOR-mediated cell growth and division. When mTOR inhibition is lost, people with TSC develop characteristic and usually benign tumors in various organ systems. Kidney tumors and cysts are common, particularly in the setting of TSC2 gene mutations. In most TSC patients, the number of kidney cysts is limited, their morphology is simple, their size is small, and their clinical significance is negligible. In some, cyst morphology progresses from simple to complex with the risk of malignant transformation. In others, aggressive accumulation and growth of kidney cysts can cause hypertension, impaired kidney function, and progression to kidney failure. This educational review summarizes current knowledge and remaining open questions regarding cystic kidney disease in TSC, emphasizing detection, classification, surveillance, and treatment options.


Assuntos
Cistos , Neoplasias Renais , Doenças Renais Policísticas , Esclerose Tuberosa , Humanos , Feminino , Masculino , Proteínas Supressoras de Tumor/genética , Esclerose Tuberosa/complicações , Esclerose Tuberosa/epidemiologia , Esclerose Tuberosa/genética , Neoplasias Renais/etiologia , Neoplasias Renais/genética , Serina-Treonina Quinases TOR , Cistos/complicações
8.
Pediatr Radiol ; 53(7): 1270-1284, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36261512

RESUMO

Magnetic resonance imaging (MRI) has emerged as the preferred imaging modality for evaluating a wide range of pediatric medical conditions. Nevertheless, the long acquisition times associated with this technique can limit its widespread use in young children, resulting in motion-degraded or non-diagnostic studies. As a result, sedation or general anesthesia is often necessary to obtain diagnostic images, which has implications for the safety profile of MRI, the cost of the exam and the radiology department's clinical workflow. Over the last decade, several techniques have been developed to increase the speed of MRI, including parallel imaging, single-shot acquisition, controlled aliasing techniques, compressed sensing and artificial-intelligence-based reconstructions. These are advantageous because shorter examinations decrease the need for sedation and the severity of motion artifacts, increase scanner throughput, and improve system efficiency. In this review we discuss a framework for image acceleration in children that includes the synergistic use of state-of-the-art MRI hardware and optimized pulse sequences. The discussion is framed within the context of pediatric radiology and incorporates the authors' experience in deploying these techniques in routine clinical practice.


Assuntos
Anestesia Geral , Imageamento por Ressonância Magnética , Humanos , Criança , Pré-Escolar , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Artefatos , Espectroscopia de Ressonância Magnética
9.
Pediatr Radiol ; 53(7): 1300-1313, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36471168

RESUMO

Magnetic resonance imaging has emerged as a preferred modality in pediatric imaging because of its high soft-tissue contrast and the lack of ionizing radiation. It is important to recognize that despite its many advantages, several challenges to performing neonatal MRI arise from the lack of patient compliance and the small size of the anatomy. This manuscript presents the approach to patient preparation used at the authors' institution, summarizes general principles of image optimization and hardware selection, and reviews common indications across various organ systems. This manuscript also incorporates input from our pediatric-trained MRI technologists, in an attempt to compile a practical guideline covering all major aspects of neonatal MRI, from its execution to its interpretation.


Assuntos
Imageamento por Ressonância Magnética , Cooperação do Paciente , Recém-Nascido , Criança , Humanos , Imageamento por Ressonância Magnética/métodos
10.
J Comput Assist Tomogr ; 46(3): 492-498, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35575655

RESUMO

OBJECTIVE: The aim of the study was to compare a pediatric ultralow-dose pectus excavatum computed tomography (CT) protocol versus standard-dose pediatric thoracic CT in terms of radiation dose, subjective and objective image quality, and its ability to detect incidental nonosseous thoracic pathology compared with imaging and clinical reference. METHODS: A single institution radiology database identified a total of 104 ultralow-dose pediatric thoracic CT cases with an equal number of age-matched standard-dose chest CT cases also selected for retrospective analysis. Objective image quality (contrast-to-noise and signal-to-noise ratios) and radiation dose were assessed. Qualitative Likert scorings of the bone, lung, and soft tissues were performed by 2 expert radiologists. Electronic health records of the ultralow-dose cohort were reviewed for at least 1 year to evaluate for potentially missed thoracic pathology and symptoms. Variables were compared using parametric and nonparametric tests in R software 4.0.5. RESULTS: The ultralow-dose protocol group had statistically significant reductions (P < 0.001) in the volume CT dose index (0.31 ± 0.19 vs 2.20 ± 1.64 mGy), effective radiation dose (0.14 ± 0.08 vs 1.07 ± 0.86 mSv), and size-specific dose estimates (0.50 ± 0.30 vs 3.43 ± 2.56 mGy) compared with the standard protocol, yielding an 86.51% and 85.32% reduction, respectively. The signal-to-noise ratio (20.49 ± 6.19 vs 36.48 ± 10.20), contrast-to-noise (21.65 ± 6.57 vs 38.47 ± 10.59), and subjective measures of image quality (lung parenchyma [3.07 ± 0.92 vs 4.42 ± 0.47], bony structures [3.30 ± 0.86 vs 4.52 ± 0.51], and surrounding soft tissues [2.57 ± 0.63 vs 3.89 ± 0.65]) were also significantly lower in the ultralow-dose protocol (P < 0.001). No differences were seen in the number and size of pulmonary nodules between groups. Clinical and imaging follow of all 104 patients undergoing ultralow-dose CT demonstrated no evidence of missed thoracic pathology causing symptoms. CONCLUSIONS: Ultralow-dose thoracic CT is an acceptable modality for imaging pediatric patients with pectus excavatum and other conditions primarily causing osseous pathology, with effective radiation dose comparable to plain radiographs and a moderate increase in image noise that did not significantly reduce its ability to detect incidental nonosseous thoracic pathology.


Assuntos
Tórax em Funil , Radiografia Torácica , Criança , Tórax em Funil/diagnóstico por imagem , Humanos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Torácica/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
11.
Pediatr Radiol ; 52(2): 152-157, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33856504

RESUMO

A pediatric MRI service is a vital component of a successful radiology department. Building an efficient and effective pediatric MRI service is a multifaceted process that requires detailed planning for considerations related to finance, operations, quality and safety, and process improvement. These are compounded by the unique challenges of caring for pediatric patients, particularly in the setting of the recent coronavirus disease 2019 (COVID-19) pandemic. In addition to material resources, a successful pediatric MRI service depends on a collaborative team consisting of radiologists, physicists, technologists, nurses and vendor specialists, among others, to identify and resolve challenges and to strive for continued improvement. This article provides an overview of the factors involved in both starting and optimizing a pediatric MRI service, including commonly encountered obstacles and some proposed solutions to address them.


Assuntos
COVID-19 , Criança , Humanos , Imageamento por Ressonância Magnética , Pandemias , Radiologistas , SARS-CoV-2
12.
Pediatr Radiol ; 52(2): 374-381, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33830290

RESUMO

Given the increasing use of MRI in the pediatric population, the need for sedation in MRI performed in young children is a topic of growing importance. Although sedation is generally tolerated well by children, the financial and operational impacts of anesthesia on MRI workflow, as well as potential adverse effects of anesthetic medications, highlight the need to perform MRI in children without sedation whenever possible. This review focuses on current techniques to facilitate non-sedation MRI in children, including exam preparation with MRI simulation; asleep but not sedated techniques; awake and relaxed techniques using certified child life specialists, animal-assisted therapy, a child-friendly environment and in-scan entertainment; and non-sedated MRI protocol modifications such as shorter scan time, prioritizing sequences, reducing motion artifact, noise reduction, limiting use of gadolinium, employing an open MRI and modifying protocols.


Assuntos
Anestesia , Terapia Assistida com Animais , Artefatos , Criança , Pré-Escolar , Sedação Consciente , Gadolínio , Humanos , Imageamento por Ressonância Magnética
13.
Pediatr Radiol ; 52(2): 401-417, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33791839

RESUMO

Pediatric patients with cancer predisposition syndromes are at increased risk of developing malignancies compared with their age-matched peers, necessitating regular surveillance. Screening protocols differ among syndromes and are composed of a number of elements, imaging being one. Surveillance can be initiated in infants, children and adolescents with a tumor known or suspected of being related to a cancer predisposition syndrome or where genetic testing identifies a germline pathogenic gene variant in an asymptomatic child. Pre-symptomatic detection of malignant neoplasms offers potential to improve treatment options and survival outcomes, but the benefits and risks of screening need to be weighed, particularly with variable penetrance in many cancer predisposition syndromes. In this review we discuss the benefits and risks of surveillance imaging and the importance of integrating imaging and non-imaging screening elements. We explore the principles of surveillance imaging with particular reference to whole-body MRI, considering the strategies to minimize false-negative and manage false-positive whole-body MRI results, the value of standardized nomenclature when reporting risk stratification to better guide patient management, and the need for timely communication of results to allay anxiety. Cancer predisposition syndrome screening is a multimodality, multidisciplinary and longitudinal process, so developing formalized frameworks for surveillance imaging programs should enhance diagnostic performance while improving the patient experience.


Assuntos
Detecção Precoce de Câncer , Neoplasias , Adolescente , Criança , Predisposição Genética para Doença , Humanos , Lactente , Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Neoplasias/genética , Síndrome
14.
Pediatr Radiol ; 52(6): 1115-1124, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35119490

RESUMO

BACKGROUND: Susceptibility-weighted imaging (SWI) is highly sensitive for intracranial hemorrhagic and mineralized lesions but is associated with long scan times. Wave controlled aliasing in parallel imaging (Wave-CAIPI) enables greater acceleration factors and might facilitate broader application of SWI, especially in motion-prone populations. OBJECTIVE: To compare highly accelerated Wave-CAIPI SWI to standard SWI in the non-sedated pediatric outpatient setting, with respect to the following variables: estimated scan time, image noise, artifacts, visualization of normal anatomy and visualization of pathology. MATERIALS AND METHODS: Twenty-eight children (11 girls, 17 boys; mean age ± standard deviation [SD] = 128.3±62 months) underwent 3-tesla (T) brain MRI, including standard three-dimensional (3-D) SWI sequence followed by a highly accelerated Wave-CAIPI SWI sequence for each subject. We rated all studies using a predefined 5-point scale and used the Wilcoxon signed rank test to assess the difference for each variable between sequences. RESULTS: Wave-CAIPI SWI provided a 78% and 67% reduction in estimated scan time using the 32- and 20-channel coils, respectively, corresponding to estimated scan time reductions of 3.5 min and 3 min, respectively. All 28 children were imaged without anesthesia. Inter-reader agreement ranged from fair to substantial (k=0.67 for evaluation of pathology, 0.55 for anatomical contrast, 0.3 for central noise, and 0.71 for artifacts). Image noise was rated higher in the central brain with wave SWI (P<0.01), but not in the peripheral brain. There was no significant difference in the visualization of normal anatomical structures and visualization of pathology between the standard and wave SWI sequences (P=0.77 and P=0.79, respectively). CONCLUSION: Highly accelerated Wave-CAIPI SWI of the brain can provide similar image quality to standard SWI, with estimated scan time reduction of 3-3.5 min depending on the radiofrequency coil used, with fewer motion artifacts, at a cost of mild but perceptibly increased noise in the central brain.


Assuntos
Artefatos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Criança , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Masculino , Neuroimagem/métodos , Projetos Piloto
15.
Neuroimage ; 238: 118210, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34062266

RESUMO

Smaller, more affordable, and more portable MRI brain scanners offer exciting opportunities to address unmet research needs and long-standing health inequities in remote and resource-limited international settings. Field-based neuroimaging research in low- and middle-income countries (LMICs) can improve local capacity to conduct both structural and functional neuroscience studies, expand knowledge of brain injury and neuropsychiatric and neurodevelopmental disorders, and ultimately improve the timeliness and quality of clinical diagnosis and treatment around the globe. Facilitating MRI research in remote settings can also diversify reference databases in neuroscience, improve understanding of brain development and degeneration across the lifespan in diverse populations, and help to create reliable measurements of infant and child development. These deeper understandings can lead to new strategies for collaborating with communities to mitigate and hopefully overcome challenges that negatively impact brain development and quality of life. Despite the potential importance of research using highly portable MRI in remote and resource-limited settings, there is little analysis of the attendant ethical, legal, and social issues (ELSI). To begin addressing this gap, this paper presents findings from the first phase of an envisioned multi-staged and iterative approach for creating ethical and legal guidance in a complex global landscape. Section 1 provides a brief introduction to the emerging technology for field-based MRI research. Section 2 presents our methodology for generating plausible use cases for MRI research in remote and resource-limited settings and identifying associated ELSI issues. Section 3 analyzes core ELSI issues in designing and conducting field-based MRI research in remote, resource-limited settings and offers recommendations. We argue that a guiding principle for field-based MRI research in these contexts should be including local communities and research participants throughout the research process in order to create sustained local value. Section 4 presents a recommended path for the next phase of work that could further adapt these use cases, address ethical and legal issues, and co-develop guidance in partnership with local communities.


Assuntos
Imageamento por Ressonância Magnética/ética , Neuroimagem/ética , Países em Desenvolvimento , Ética em Pesquisa , Humanos
16.
J Magn Reson Imaging ; 53(1): 132-138, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32558062

RESUMO

BACKGROUND: Patient genetic polymorphism is associated with Crohn's clinical behavior; however, its association with magnetic resonance enterography (MRE) imaging appearance is not known. PURPOSE: To analyze a set of known Crohn's disease (CD)-related single nucleotide polymorphisms for associations with MRE imaging phenotype and frequency of imaging. STUDY TYPE: Retrospective. POPULATION: 54 patients (mean age 40 years; 32 females and 22 males) with established CD from 2009 to 2016 who underwent baseline MRE and genetic testing for the presence of 168 single nucleotide polymorphisms (SNPs) potentially associated with inflammatory bowel disease. FIELD STRENGTH/SEQUENCE: 1.5T or 3T clinical scanners, standard MRE clinical pulse sequences, including T2 -weighted single-shot fast spin echo, balanced steady-state free precession, T2 -weighted fast spin echo fat-suppressed, and T1 -weighted fat-suppressed pre- and postcontrast imaging. ASSESSMENT: Three readers (all body imaging fellowship-trained radiologists) independently evaluated all imaging for the presence or absence of active disease and penetrating complications. Date of onset and frequency of endoscopies and cross-sectional imaging (CSI) were recorded. Disease behavior and distribution were categorized according to the Vienna and Montreal classifications, respectively. STATISTICAL TESTS: Student's t-test and Fisher's exact test were used to assess significance of continuous and categorical variables, respectively. A hidden Markov model statistical knockoff approach was also applied for the analysis of genetic-imaging associations, with corrected P < 0.05 considered significant. RESULTS: MRE demonstrated active bowel inflammation in 42 (78%) patients, strictures in 13 (28%), and fistulae in 13 (28%). The SNP rs1292053 (RBS6KB1) was highly associated with small bowel inflammation and luminal narrowing, with observed frequencies of association 0.66 and 0.39, respectively (P = 0.001). rs6062504 (Decoy receptor 3) was associated with lower age of onset (P = 0.012), higher proportion of early disease onset patients (P = 0.012), and higher average number of CSI/year (P = 0.014). DATA CONCLUSION: This study demonstrated significant associations between CD genotype and MRE phenotype and frequency of cross-sectional imaging. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Doença de Crohn , Adulto , Meios de Contraste , Doença de Crohn/diagnóstico por imagem , Doença de Crohn/genética , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Polimorfismo de Nucleotídeo Único , Estudos Retrospectivos
17.
Eur Radiol ; 31(8): 5759-5767, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33454799

RESUMO

OBJECTIVES: Intra-tumor heterogeneity has been previously shown to be an independent predictor of patient survival. The goal of this study is to assess the role of quantitative MRI-based measures of intra-tumor heterogeneity as predictors of survival in patients with metastatic colorectal cancer. METHODS: In this IRB-approved retrospective study, we identified 55 patients with stage 4 colon cancer with known hepatic metastasis on MRI. Ninety-four metastatic hepatic lesions were identified on post-contrast images and manually volumetrically segmented. A heterogeneity phenotype vector was extracted from each lesion. Univariate regression analysis was used to assess the contribution of 110 extracted features to survival prediction. A random forest-based machine learning technique was applied to the feature vector and to the standard prognostic clinical and pathologic variables. The dataset was divided into a training and test set at a ratio of 4:1. ROC analysis and confusion matrix analysis were used to assess classification performance. RESULTS: Mean survival time was 39 ± 3.9 months for the study population. A total of 22 texture features were associated with patient survival (p < 0.05). The trained random forest machine learning model that included standard clinical and pathological prognostic variables resulted in an area under the ROC curve of 0.83. A model that adds imaging-based heterogeneity features to the clinical and pathological variables resulted in improved model performance for survival prediction with an AUC of 0.94. CONCLUSIONS: MRI-based texture features are associated with patient outcomes and improve the performance of standard clinical and pathological variables for predicting patient survival in metastatic colorectal cancer. KEY POINTS: • MRI-based tumor heterogeneity texture features are associated with patient survival outcomes. • MRI-based tumor texture features complement standard clinical and pathological variables for prognosis prediction in metastatic colorectal cancer. • Agglomerative hierarchical clustering shows that patient survival outcomes are associated with different MRI tumor profiles.


Assuntos
Neoplasias do Colo , Neoplasias Retais , Neoplasias do Colo/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Imageamento por Ressonância Magnética , Estudos Retrospectivos
18.
AJR Am J Roentgenol ; 216(3): 799-805, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32755164

RESUMO

BACKGROUND. Anesthetic exposure in children may impact long-term neurocognitive outcomes. Therefore, minimizing pediatric MRI scan time in children under anesthesia and the associated anesthetic exposure is necessary. OBJECTIVE. The purpose of this study was to evaluate pediatric MRI scan time as a predictor of total propofol dose, considering imaging and clinical characteristics as covariates. METHODS. Electronic health records were retrospectively searched to identify MRI examinations performed from 2016 to 2019 in patients 0-18 years old who received propofol anesthetic. Brain; brain and spine; brain and abdomen; and brain, head, and neck MRI examinations were included. Demographic, clinical, and imaging data were extracted for each examination, including anesthesia maintenance phase time, MRI scan time, and normalized propofol dose. MRI scan time and propofol dose were compared between groups using a t test. A multiple linear regression with backward selection (threshold, p < .05) was used to evaluate MRI scan time as a predictor of total propofol dose, adjusting for sex, age, time between scan and study end, body part, American Society of Anesthesiologists (ASA) classification, diagnosis, magnet strength, and IV contrast medium administration as covariates. RESULTS. A total of 501 examinations performed in 426 patients (172 girls, 254 boys; mean age, 6.55 ± 4.59 [SD] years) were included. Single body part examinations were shorter than multiple body part examinations (mean, 52.7 ± 18.4 vs 89.3 ± 26.4 minutes) and required less propofol (mean, 17.7 ± 5.7 vs 26.1 ± 7.7 mg/kg; all p < .001). Among single body part examinations, a higher ASA classification, oncologic diagnosis, 1.5-T magnet, and IV contrast medium administration were associated with longer MRI scan times (all p ≤ .009) and higher propofol exposure (all p ≤ .005). In multivariable analysis, greater propofol exposure was predicted by MRI scan time (mean dose per minute of examination, 0.178 mg/kg; 95% CI, 0.155-0.200; p < .001), multiple body part examination (p = .04), and IV contrast medium administration (p = .048); lower exposure was predicted by 3-T magnet (p = .04). CONCLUSION. Anesthetic exposure during pediatric MRI can be quantified and predicted based on imaging and clinical variables. CLINICAL IMPACT. This study serves as a valuable baseline for future efforts to reduce anesthetic doses and scan times in pediatric MRI.


Assuntos
Anestésicos Intravenosos/administração & dosagem , Imageamento por Ressonância Magnética/estatística & dados numéricos , Propofol/administração & dosagem , Abdome/diagnóstico por imagem , Adolescente , Anestésicos Intravenosos/efeitos adversos , Encéfalo/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Cabeça/diagnóstico por imagem , Humanos , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Pescoço/diagnóstico por imagem , Propofol/efeitos adversos , Estudos Retrospectivos , Coluna Vertebral/diagnóstico por imagem , Fatores de Tempo
19.
Radiographics ; 41(6): 1632-1656, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34597220

RESUMO

Gastrointestinal (GI) bleeding is a common potentially life-threatening medical condition frequently requiring multidisciplinary collaboration to reach the proper diagnosis and guide management. GI bleeding can be overt (eg, visible hemorrhage such as hematemesis, hematochezia, or melena) or occult (eg, positive fecal occult blood test or iron deficiency anemia). Upper GI bleeding, which originates proximal to the ligament of Treitz, is more common than lower GI bleeding, which arises distal to the ligament of Treitz. Small bowel bleeding accounts for 5-10% of GI bleeding cases commonly manifesting as obscure GI bleeding, where the source remains unknown after complete GI tract endoscopic and imaging evaluation. CT can aid in identifying the location and cause of bleeding and is an important complementary tool to endoscopy, nuclear medicine, and angiography in evaluating patients with GI bleeding. For radiologists, interpreting CT scans in patients with GI bleeding can be challenging owing to the large number of images and the diverse potential causes of bleeding. The purpose of this pictorial review by the Society of Abdominal Radiology GI Bleeding Disease-Focused Panel is to provide a practical resource for radiologists interpreting GI bleeding CT studies that reviews the proper GI bleeding terminology, the most common causes of GI bleeding, key patient history and risk factors, the optimal CT imaging technique, and guidelines for case interpretation and illustrates many common causes of GI bleeding. A CT reporting template is included to help generate radiology reports that can add value to patient care. An invited commentary by Al Hawary is available online. Online supplemental material is available for this article. ©RSNA, 2021.


Assuntos
Angiografia por Tomografia Computadorizada , Gastroenteropatias , Angiografia , Endoscopia Gastrointestinal , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Tomografia Computadorizada por Raios X
20.
Pediatr Radiol ; 51(1): 77-85, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32845348

RESUMO

BACKGROUND: Diffusion-weighted imaging (DWI) is a useful MRI technique to characterize abdominal lesions in children, but long acquisition times can lead to image degradation. Simultaneous multi-slice accelerated DWI is a promising technique to shorten DWI scan times. OBJECTIVE: To test the feasibility of simultaneous multi-slice DWI of the kidneys in pediatric patients with tuberous sclerosis complex (TSC) and to evaluate the accelerated protocol regarding image quality and quantitative apparent diffusion coefficient (ADC) values compared to standard echoplanar DWI sequence. MATERIALS AND METHODS: We included 33 children and adolescents (12 female, 21 male; mean age 10±5 years) with TSC and renal cyst or angiomyolipoma on 3-tesla (T) MRI from 2017 to 2019. All studies included both free-breathing standard echoplanar DWI and simultaneous multi-slice DWI sequences. Subjective and quantitative image quality was evaluated using a predefined 5-point scale. ADC values were obtained for all renal cysts and angiomyolipomas ≥5 mm. All statistical analysis was performed using Stata/SE v15.1. RESULTS: Simultaneous multi-slice DWI ADC values were slightly lower compared to standard echoplanar DWI for both renal cysts and angiomyolipomas (mean difference 0.05×10-3 mm2/s, 95% confidence interval [CI] 0.40-0.50 and 0.024×10-3 mm2/s, 95% CI 0.17-0.21, respectively, with P>0.1). Our results showed that renal lesions with ADC values >1.69×10-3 mm2/s were all cysts, whereas lesions with values <1.16×10-3 mm2/s were all angiomyolipomas. However, ADC values could not discriminate between lipid-rich and lipid-poor angiomyolipomas (P>0.1, for both sequences). CONCLUSION: A 55% reduction in scan time was achieved using simultaneous multi-slice DWI for abdominal imaging in children with TSC, with near identical image quality as standard DWI. These results suggest that multi-slice techniques should be considered more broadly as an MRI acceleration technique in children.


Assuntos
Esclerose Tuberosa , Adolescente , Criança , Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Feminino , Humanos , Recém-Nascido , Rim , Masculino , Reprodutibilidade dos Testes , Esclerose Tuberosa/complicações , Esclerose Tuberosa/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA