Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 205
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Am Heart J ; 256: 139-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36410441

RESUMO

BACKGROUND: Surgical aortic valve bioprostheses may degenerate over time and require redo intervention. Transcatheter aortic valve replacement (TAVR) is a less invasive alternative to redo surgery. The BAlloon Expandable vs. SElf Expanding Transcatheter VaLve for Degenerated BioprosthesIs (BASELINE) trial was designed to compare the performance of the balloon-expandable SAPIEN-3 Ultra and the self-expanding EVOLUT PRO+ valve systems in symptomatic patients with a failing surgical bioprosthesis. METHODS: The BASELINE trial is an investigator-initiated, non-funded, prospective, randomized, open-label, superiority trial enrolling a total of 440 patients in up to 50 sites in 12 countries in Europe and North-America. The primary endpoint is device success at 30-days defined by the Valve Academic Research Consortium-3 Criteria as the composite of technical success, freedom from mortality, freedom for surgery or intervention related to the device or to a major vascular or access-related or cardiac structural complication with an intended performance of the valve (mean gradient <20 mmHg and less than moderate aortic regurgitation). The co-primary endpoint at 1 year is defined as the composite of all-cause death, disabling stroke, rehospitalization for heart failure or valve related problems. Independent Core Laboratories will conduct uniform analyses of echocardiography (pre-, post-, 1-year post-procedure), multi-sliced computed tomography (pre-, and if available post-procedure) and cine-fluoroscopy studies. CONCLUSIONS: The BASELINE trial is a head-to-head comparative trial investigating the 2 most used contemporary transcatheter heart valves for the treatment of a failing surgical aortic bioprosthesis. (ClinicalTrials.gov number NCT04843072).


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/métodos
2.
Arch Phys Med Rehabil ; 101(4): 650-657, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31904342

RESUMO

OBJECTIVE: To examine the strength of the association between exercise capacity and health-related quality of life (HRQOL) during and after cardiac rehabilitation (CR) in patients with acute coronary syndrome (ACS) who completed CR. DESIGN: Prospective cohort study. SETTING: Outpatient CR center. PARTICIPANTS: Patients (N=607) with ACS who completed CR. INTERVENTIONS: Multidisciplinary 12-week exercise-based CR program. MAIN OUTCOME MEASURES: At baseline (pre-CR), the 6-Minute Walk Test (6MWT) was performed to determine exercise capacity, and the MacNew Heart Disease Health-related Quality of Life questionnaire was used to assess HRQOL. Measurements were repeated immediately after completion of CR (post-CR): at 12 months and 18 months follow-up. Multivariable linear regression, including an interaction term for time and exercise capacity, was applied to study the association between exercise capacity and HRQOL at different time points relative to CR, whereas model parameters were estimated by methods that accounted for dependency of repeated observations within individuals. RESULTS: Mean age in years ± SD was 58±8.9 and 82% of participants were male. Baseline mean 6MWT distance in meters ± SD was 563±77 and median (25th-75th percentile) global HRQOL was 5.5 (4.6-6.1) points. Mean 6MWT distance (P<.001) and the global (P<.001), physical (P<.001), emotional (P<.001) and social (P<.001) domains of HRQOL improved significantly during CR and continued to improve during follow-up post-CR. Independent of the timing relative to CR (ie, pre-CR, post-CR, or during follow-up), a difference of 10 m 6MWT distance was associated with a mean difference in the global HRQOL domain of 0.007 (95% confidence interval [CI], 0.001-0.014) points (P=.029) and a mean difference in the physical domain of 0.009 (95% CI, 0.001-0.017) points (P=.023). CONCLUSIONS: Better exercise capacity was significantly associated with higher scores on the global and physical domains of HRQOL, irrespective of the timing relative to CR, albeit these associations were weak. Hence, CR programs in secondary prevention should continue to aim at enhancing both HRQOL and exercise capacity.


Assuntos
Síndrome Coronariana Aguda/reabilitação , Reabilitação Cardíaca , Tolerância ao Exercício , Qualidade de Vida , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Teste de Caminhada
3.
Cardiovasc Ultrasound ; 18(1): 40, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32993683

RESUMO

BACKGROUND: Shear waves are generated by the closure of the heart valves. Significant differences in shear wave velocity have been found recently between normal myocardium and disease models of diffusely increased muscle stiffness. In this study we correlate in vivo myocardial shear wave imaging (SWI) with presence of scarred tissue, as model for local increase of stiffness. Stiffness variation is hypothesized to appear as velocity variation. METHODS: Ten healthy volunteers (group 1), 10 hypertrophic cardiomyopathy (HCM) patients without any cardiac intervention (group 2), and 10 HCM patients with prior septal reduction therapy (group 3) underwent high frame rate tissue Doppler echocardiography. The SW in the interventricular septum after aortic valve closure was mapped along two M-mode lines, in the inner and outer layer. RESULTS: We compared SWI to 3D echocardiography and strain imaging. In groups 1 and 2, no change in velocity was detected. In group 3, 8/10 patients showed a variation in SW velocity. All three patients having transmural scar showed a simultaneous velocity variation in both layers. Out of six patients with endocardial scar, five showed variations in the inner layer. CONCLUSION: Local variations in stiffness, with myocardial remodeling post septal reduction therapy as model, can be detected by a local variation in the propagation velocity of naturally occurring shear waves.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/fisiopatologia , Ecocardiografia Doppler/métodos , Ecocardiografia Tridimensional/métodos , Adolescente , Adulto , Cardiomiopatia Hipertrófica/cirurgia , Cicatriz/diagnóstico por imagem , Cicatriz/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas
4.
Echocardiography ; 36(5): 980-986, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30905087

RESUMO

Both transesophageal echocardiography (TEE) and intracardiac echocardiography have been used to assist transvenous lead extractions. The clinical utility of continuous echocardiographic monitoring during the procedure is still debated, with different reports supporting opposite findings. In cases where the procedure is expected to be difficult, we propose adding a continuous TEE monitoring using a static 3D/multiplane probe in mid-esophageal position, with digital remote manipulation of the field of view. This approach may improve the chances of a successful extraction, increase safety, or even guide the entire intervention. We present here a short case series where continuous monitoring by TEE played an important role.


Assuntos
Remoção de Dispositivo/métodos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Coração/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Adulto , Idoso , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Radiologia Intervencionista/métodos
5.
J Nucl Cardiol ; 25(2): 471-479, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27444501

RESUMO

BACKGROUND: Both dobutamine stress echocardiography (DSE) and myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) are frequently used for cardiac risk stratification. The long-term relative prognostic value of these modalities has not been studied. Therefore, this study evaluated the long-term prognostic value of DSE compared to MPI in patients unable to perform exercise testing. METHODS: This prospective, single center study included 301 patients (mean age 59 ± 12 years, 56% men) unable to perform exercise tests who underwent DSE and dobutamine stress 99mTc-sestamibi MPI. End points during follow-up were all-cause mortality, cardiac mortality, and nonfatal myocardial infarction (MI). Univariable and multivariable Cox proportional hazards regression models were used to identify independent predictors of outcome. The probability of survival was calculated using the Kaplan-Meier method. RESULTS: A total of 182 patients (60%) had an abnormal DSE and 198 (66%) patients had an abnormal MPI. The agreement between DSE and MPI was 82% (κ = 0.62). During a median follow-up of 14 years (range 5-18), 172 deaths (57%) occurred, of which 72 (24%) were due to cardiac causes. Nonfatal MI occurred in 46 patients (15%). The multivariable analysis demonstrated that an abnormal DSE was a significant predictor of cardiac mortality (HR 2.35, 95% CI [1.17-4.73]) and hard cardiac events (HR 2.11, 95% CI [1.25-3.57]). Also, an abnormal MPI result was a significant predictor of cardiac mortality (HR 3.03, 95% CI [1.33-6.95]) and hard cardiac events (HR 2.06, 95% CI [1.12-3.79]). CONCLUSIONS: DSE and MPI are comparable in predicting long-term cardiac mortality and hard cardiac events in patients unable to perform exercise testing.


Assuntos
Dobutamina/química , Ecocardiografia sob Estresse , Coração/diagnóstico por imagem , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Infarto do Miocárdio/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Prognóstico , Modelos de Riscos Proporcionais , Estudos Prospectivos
6.
Echocardiography ; 34(2): 199-209, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28240430

RESUMO

AIMS: The feasibility and accuracy of an automated adaptive algorithm (Heart Model) for the quantification of left heart chamber volumes and left ventricular ejection fraction has been reported earlier. An improved version of the algorithm is available, and we aimed to test its accuracy compared with manual 3D echocardiography. METHODS AND RESULTS: Apical 3D transthoracic datasets were obtained in 67 patients. Acquisitions covering ventricles and atria were performed for analysis using the automated software (Heart Model, Philips Healthcare). In addition, acquisitions focused on the left ventricle were acquired for left ventricle manual 3D measurements (QLAB 10 3DQA, Philips Healthcare). Automated results using endocardial contouring settings at 50% showed a strong correlation with manual 3D measurements (r=.84-.97). Left ventricular end-diastolic volumes were underestimated (bias -5.9 mL, LOA ±38.5 mL), with no significant differences in other parameters. Intra-observer variability using the automated algorithm was zero for all parameters given the lack of human interaction. Manual corrections of the automatic algorithm introduced small but significant differences in volumes but not in ejection fraction when compared with automatic results. Manually corrected results of the automatic algorithm were not significantly different from those obtained with manual 3D echocardiography, except for a small underestimation of left atrial volumes (bias -2.1 mL, LOA ±15.2 mL). CONCLUSIONS: The current improved version of the automated adaptive algorithm is accurate for the assessment of left heart chamber volumes, albeit a small underestimation of left ventricular end-diastolic volume is seen, when compared with manual 3D echocardiography.


Assuntos
Ecocardiografia Tridimensional/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Algoritmos , Estudos de Viabilidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
7.
J Heart Valve Dis ; 25(3): 289-295, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27989038

RESUMO

BACKGROUND: The echocardiographic grading of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) severity is challenging. The study aim was to assess the value of quantitative Doppler echocardiography to monitor PVL severity. METHODS: A total of 100 subjects was enrolled in the study, including 65 consecutive patients who had undergone TAVI with a CoreValve prosthesis and without valvular aortic regurgitation, and 35 normal controls. The PVL volume was calculated using the quantitative Doppler method as the difference of left and right ventricular stroke volume (SV). PVL severity was assessed both visually and quantitatively as the circumferential extent on a short-axis view (SAX). RESULTS: The inter-observer variabilities for SVs in TAVI patients were disappointing: 14 ± 11% for the left ventricular SV and 18 ± 14% for right ventricular SV. The correlation (r2) between the averaged regurgitant PVL volume and circumferential SAX extent of PVL was 0.02 (p = NS). The relationship between PVL volumes and categories, defined quantitatively by the circumferential SAX extent of PVL and qualitatively by visual assessment of severity of PVL were poor. The results improved when only patients with optimal quality images were included but were still statistically non-significant. CONCLUSIONS: The relationship between calculated PVL volume in TAVI patients and other estimates of PVL severity was poor, most likely due to intrinsic errors made in the quantitative Doppler method. Therefore, one should be prudent to include the quantitative Doppler method in TAVI patients in clinical trials and clinical decision-making, in particular in patients with reduced image quality.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Substituição da Valva Aórtica Transcateter/efeitos adversos , Adulto , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estudos de Casos e Controles , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita
8.
Cardiovasc Ultrasound ; 14(1): 37, 2016 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-27600600

RESUMO

To make assessment of paravalvular aortic leakage (PVL) after transcatheter aortic valve implantation (TAVI) more uniform the second Valve Academic Research Consortium (VARC) recently updated the echocardiographic criteria for mild, moderate and severe PVL. In the VARC recommendation the assessment of the circumferential extent of PVL in the short-axis view is considered critical. In this paper we will discuss our observational data on the limitations and difficulties of this particular view, that may potentially result in overestimation or underestimation of PVL severity.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco
9.
Echocardiography ; 33(3): 353-61, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26522441

RESUMO

AIMS: The aim of this study was to evaluate the feasibility of transthoracic two-dimensional (2D) iRotate, a new echo modality, to assess the whole right ventricle (RV) from a single transducer position based on anatomic landmarks. METHODS AND RESULTS: The anatomic landmarks were first defined based on three-dimensional echocardiographic datasets using multiplane reconstruction analyses. Thereafter, we included 120 healthy subjects (51% male, age range 21-67 years). Using 2D iRotate, four views of the RV could be acquired based on these landmarks. The anterior, lateral, inferior wall (divided into three segments: basal-mid-apical), and right ventricular outflow tract (RVOT) anterior wall of the RV were determined. The feasibility of visualization of RV segments and tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler imaging (TDI) measurements were assessed. To evaluate this model for diseased RVs, a small pilot study of 20 patients was performed. In 98% of healthy subjects and 100% of patients, iRotate mode was feasible to assess the RV from one single transducer position. In total, 86% and 95%, respectively, of the RV segments could be visualized. The visualization of the RVOT anterior wall was worse 23% and 75%, respectively. TAPSE and TDI measurements on all four views were feasible 93% and 92%, respectively, of the healthy subjects and in 100% of the patients. CONCLUSION: With 2D iRotate, a comprehensive evaluation of the entire normal and diseased RV is feasible from a fixed transducer position based on anatomic landmarks. This is less time-consuming than the multiview approach and enhances accuracy of RV evaluation. Imaging of the RVOT segment remains challenging.


Assuntos
Pontos de Referência Anatômicos/diagnóstico por imagem , Ecocardiografia/métodos , Ecocardiografia/normas , Ventrículos do Coração/diagnóstico por imagem , Modelos Cardiovasculares , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Idoso , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Aumento da Imagem/normas , Interpretação de Imagem Assistida por Computador/métodos , Interpretação de Imagem Assistida por Computador/normas , Masculino , Pessoa de Meia-Idade , Países Baixos , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
10.
Circ Res ; 113(2): 153-66, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23658436

RESUMO

RATIONALE: Mesenchymal precursor cells (MPCs) are a specific Stro-3+ subpopulation of mesenchymal stem cells isolated from bone marrow. MPCs exert extensive cardioprotective effects, and are considered to be immune privileged. OBJECTIVE: This study assessed the safety, feasibility, and efficacy of intracoronary delivery of allogeneic MPCs directly after acute myocardial infarction in sheep. METHODS AND RESULTS: Initially, intracoronary delivery conditions were optimized in 20 sheep. These conditions were applied in a randomized study of 68 sheep with an anterior acute myocardial infarction. Coronary flow was monitored during MPC infusion, and cardiac function was assessed using invasive hemodynamics and echocardiography at baseline and during 8 weeks follow-up. Coronary flow remained within thrombolysis in myocardial infarction III definitions in all sheep during MPC infusion. Global left ventricular ejection fraction as measured by pressure-volume loop analysis deteriorated in controls to 40.7±2.6% after 8 weeks. In contrast, MPC treatment improved cardiac function to 52.8±0.7%. Echocardiography revealed significant improvement of both global and regional cardiac functions. Infarct size decreased by 40% in treated sheep, whereas infarct and border zone thickness were enhanced. Left ventricular adverse remodeling was abrogated by MPC therapy, resulting in a marked reduction of left ventricular volumes. Blood vessel density increased by >50% in the infarct and border areas. Compensatory cardiomyocyte hypertrophy was reduced in border and remote segments, accompanied by reduced collagen deposition and apoptosis. No microinfarctions in remote myocardial segments or histological abnormalities in unrelated organs were found. CONCLUSIONS: Intracoronary infusion of allogeneic MPCs is safe, feasible, and markedly effective in a large animal model of acute myocardial infarction.


Assuntos
Vasos Coronários/fisiologia , Transplante de Células-Tronco Mesenquimais/métodos , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/fisiologia , Animais , Seguimentos , Infusões Intra-Arteriais , Infarto do Miocárdio/fisiopatologia , Distribuição Aleatória , Ovinos , Transplante Homólogo
11.
BMC Cardiovasc Disord ; 15: 28, 2015 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-25943388

RESUMO

BACKGROUND: Physicians utilize different types of information to predict patient prognosis. For example: confronted with a new patient suffering from severe aortic stenosis (AS), the cardiologist considers not only the severity of the AS but also patient characteristics, medical history, and markers such as BNP. Intuitively, doctors adjust their prediction of prognosis over time, with the change in clinical status, aortic valve area and BNP at each outpatient clinic visit. With the help of novel statistical approaches to model outcomes, it is now possible to construct dynamic event prediction models, employing longitudinal data such as AVA and BNP, and mimicking the dynamic adjustment of prognosis as employed intuitively by cardiologists. We illustrate dynamic prediction of patient survival and freedom from intervention, using baseline patient characteristics and longitudinal BNP data that are becoming available over time, from a cohort of patients with severe aortic stenosis. METHODS: A 3-step approach was employed: (1) construction of a mixed-effects model to describe temporal BNP progression, (2) jointly modeling the mixed-effects model with time-to-event data (death and freedom from intervention), and (3) using the joint model to build subject-specific prediction risk models. The dataset used for this purpose includes 191 patients with severe aortic stenosis who were followed over a 3-year time period. RESULTS: In the mixed-effects model BNP was significantly influenced by time, baseline patient age, gender, LV fractional ejection fraction and creatinine. Additionally, the joint model showed that an increasing BNP trend over time was found to be a significant predictor of death. CONCLUSIONS: By jointly modeling longitudinal data with time-to-event outcomes it is possible to construct individualized dynamic event prediction models that renew over time with accumulating evidence. It provides a potentially valuable evidence-based tool for everyday use in medical practice.


Assuntos
Estenose da Valva Aórtica/mortalidade , Modelos Estatísticos , Fatores Etários , Idoso , Estenose da Valva Aórtica/sangue , Biomarcadores/sangue , Creatinina/sangue , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Prognóstico , Medição de Risco/métodos , Fatores Sexuais , Volume Sistólico , Fatores de Tempo
12.
Cardiovasc Ultrasound ; 13: 29, 2015 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-26113031

RESUMO

BACKGROUND: Symptoms in the elderly patients with severe aortic stenosis (AS) and co-morbidities seem to lack in specificity. Therefore, objective parameters for increased left ventricular(LV) filling pressures are needed. The aim of this study was to investigate the correlation between the septal, lateral and average E/e' ratio and the value of the N-terminal pro-hormone of brain natriuretic peptide (NT-proBNP). METHODS: Two-hundred-fifty consecutive symptomatic patients (mean age 80 ± 8 years, 52% men) with severe AS underwent transthoracic echocardiography and NT-proBNP measurement. RESULTS: In the overall population the septal E/e' (r = 0,459, r(2) = 0,21, P <0,0001), lateral E/e' (r = 0,322, r(2) = 0,10, P <0,0001), and the average E/e' (r = 0,432, r(2) = 0,18, P <0,0001) were all significantly correlated to NT-proBNP. After the exclusion of patients with confounders (more than mild aortic or mitral regurgitation, severe renal dysfunction, obesity or severe COPD) the septal E/e' (r = 0,584, r(2) = 0,34, P <0,0001), lateral E/e' (r = 0,377, r(2) = 0,14, P <0,0001), and the average E/e' (r = 0,487, r(2) = 0,24, P <0,0001) were all significantly better correlated to NT-proBNP. In obese patients no significant correlations were seen. Previous bypass surgery did not alter the correlations. CONCLUSIONS: In elderly patients with severe symptomatic AS there is a significant correlation between the E/e' ratio and NT-proBNP, in particular after exclusion of confounders. The correlation was best for the septal E/e' ratio and was preserved in patients with a history of bypass surgery.


Assuntos
Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/diagnóstico por imagem , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Volume Sistólico , Disfunção Ventricular Esquerda/sangue , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Biomarcadores/sangue , Ecocardiografia/métodos , Feminino , Avaliação Geriátrica/métodos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estatística como Assunto , Disfunção Ventricular Esquerda/etiologia
13.
Am J Physiol Heart Circ Physiol ; 307(10): H1430-7, 2014 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25217651

RESUMO

The purpose of this study was to assess left atrial (LA) function and myocardial mechanics in patients with degenerative mitral regurgitation (MR). Eighty patients with degenerative MR and twenty control subjects were included prospectively. LA volume (LAV) and right atrial (RA) volume (RAV) were measured with three-dimensional transthoracic echocardiography at three phases of the cardiac cycle as maximal volume (LAVmax and RAVmax), minimal volume (LAVmin and RAVmin), and volume before atrial contraction (LAVpre-A and RAVpre-A). From these volumes, active stroke volume (SV), distensibility, and emptying fraction were calculated. LA strain and strain rate were measured with vector velocity imaging on four- and two-chamber views. Left ventricular (LV) filling pressures were increased in patients with severe MR (E/E': 16 ± 4 vs. 10 ± 3 in control subjects). LAVmax, LAVmin, and LAVpre-A all increased with increasing MR volume. As LAVpre-A increased, both LA total SV (r = 0.68, P < 0.001) and passive filling volume (r = 0.76, P < 0.001) increased. LA active SV increased with LAVpre-A up to a certain point, upon which it decreased despite further increased LAVpre-A (r = 0.53, P < 0.001). LA late negative strain decreased with increasing MR volume. A positive correlation existed between LA late negative strain and LA active emptying fraction (r = 0.55, P < 0.001). In contrast, RA function was comparable between groups. In conclusion, LA contractility (active SV) increased in response to an increase in LA preload (LAVpre-A) up to a point beyond which LA contractility (active SV) decreased. Whether this is due to working of the LA at the descending limb of the Frank-Starling curve or mainly due to changes in afterload still remains unclear.


Assuntos
Função do Átrio Esquerdo , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Contração Miocárdica , Adaptação Fisiológica , Idoso , Estudos de Casos e Controles , Ecocardiografia Tridimensional , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Modelos Cardiovasculares , Estudos Prospectivos , Fatores de Tempo , Função Ventricular Esquerda , Pressão Ventricular
14.
J Heart Valve Dis ; 23(6): 721-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25790619

RESUMO

BACKGROUND AND AIM OF THE STUDY: Mitral regurgitation (MR) is a common disorder for which mitral valve surgery is an established therapy. Although surgical indications are clearly defined for the management of valvular heart disease, a gap exists between current guidelines and their effective application. The study aim was to provide an insight into the diagnostic information provided for cardiac surgeons before performing mitral valve surgery. METHODS: The source documents and echocardiographic studies of 100 patients, referred by nine hospitals, were screened for arguments for MR severity justifying referral for surgery. Details of the documented MR mechanism, mitral annulus (MA) size, tricuspid regurgitation (TR) severity and annulus size were also noted. RESULTS: According to the referring physician, MR was severe in 83% and moderate-to-severe in 17%. In the great majority of patients (98%) the MR mechanism was mentioned, although specific information on the prolapsing scallops was available in only 17% of cases. The recommended primary determinants of MR severity, vena contracta and proximal isovelocity surface area (PISA) were measured in only 22% and 31% of patients, respectively. In 94% of patients with available PISA information this was described only qualitatively. Correct image expansion using the zoom mode was performed in only 25% of these patients, and a correct adaptation of the Nyquist limit in only 6%. Tricuspid annulus measurements guiding the need for concomitant tricuspid valvuloplasty in patients with less than severe TR were reported in only 6% of patients. CONCLUSION: These data demonstrate a clear and important gap between current guidelines and real-world practice with regards to the echocardiographic diagnostic information provided to the surgeon before performing mitral valve surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Fidelidade a Diretrizes , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Idoso , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Transesofagiana/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Avaliação das Necessidades , Países Baixos , Seleção de Pacientes , Guias de Prática Clínica como Assunto , Encaminhamento e Consulta , Índice de Gravidade de Doença , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia
15.
JACC Case Rep ; 29(3): 102193, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361565

RESUMO

Left ventricular outflow tract obstruction (LVOTO) is a notorious complication of transcatheter mitral valve replacement (TMVR). Computed tomography-derived simulations can predict neo-LVOTO post-TMVR, whereas alcohol septal ablation (ASA) can mitigate neo-LVOTO risk. We report a case of sequential ASA of 2 adjacent septal branches to resolve unexpected neo-LVOTO post-TMVR.

16.
Artigo em Inglês | MEDLINE | ID: mdl-38795109

RESUMO

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.

17.
Echocardiography ; 30(3): 293-300, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23347129

RESUMO

BACKGROUND: Angina and an electrocardiographic strain pattern are potential manifestations of subendocardial ischemia in aortic stenosis (AS). Left ventricular (LV) twist is known to increase proportionally to the severity of AS, which may be a result of loss of the inhibiting effect of the subendocardial fibers due to subendocardial dysfunction. It has also been shown that the ratio of LV twist to circumferential shortening of the endocardium (twist-to-shortening ratio [TSR]) is a reliable parameter of subendocardial dysfunction. The aim of this study was to investigate whether these markers are increased in AS patients with angina and/or electrocardiographic strain. METHODS: The study comprised 60 AS patients with an aortic valve area <2.0 cm(2) and LV ejection fraction >50%, and 30 healthy-for age and gender matched-control subjects. LV rotation parameters were determined by speckle tracking echocardiography. RESULTS: Comparison of patients without angina and strain (n = 22), with either angina or strain (n = 28), and with both angina and strain (n = 8), showed highest peak systolic LV apical rotation, peak systolic LV twist, and TSR, in patients with more signs of subendocardial ischemia. In a multivariate linear regression model, only severity of AS and the presence of angina and/or strain could be identified as independent predictors of peak systolic LV twist and TSR. CONCLUSIONS: Peak systolic LV twist and TSR are increased in AS patients and related to the severity of AS and symptoms (angina) or electrocardiographic signs (strain) compatible with subendocardial ischemia.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Técnicas de Imagem por Elasticidade/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Idoso , Estenose da Valva Aórtica/complicações , Ecocardiografia/métodos , Módulo de Elasticidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
18.
Echocardiography ; 30(8): 961-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23489320

RESUMO

AIMS: The twisting motion of the heart has an important role in the function of the left ventricle. Speckle tracking echocardiography is able to quantify left ventricular (LV) rotation and twist. So far this new technique has not been used in congenital heart disease patients. The aim of our study was to investigate the feasibility and the intra- and inter-observer reproducibility of LV rotation parameters in adult patients with congenital heart disease. METHODS AND RESULTS: The study population consisted of 66 consecutive patients seen in the outpatient clinic (67% male, mean age 31 ± 7.7 years, NYHA class 1 ± 0.3) with a variety of congenital heart disease. First, feasibility was assessed in all patients. Intra- and inter-observer reproducibility was assessed for the patients in which speckle tracking echocardiography was feasible. Adequate image quality, for performing speckle echocardiography, was found in 80% of patients. The bias for the intra-observer reproducibility of the LV twist was 0.0°, with 95% limits of agreement of -2.5° and 2.5° and for interobserver reproducibility the bias was 0.0°, with 95% limits of agreement of -3.0° and 3.0°. Intra- and inter-observer measurements showed a strong correlation (0.86 and 0.79, respectively). Also a good repeatability was seen. The mean time to complete full analysis per subject for the first and second measurement was 9 and 5 minutes, respectively. CONCLUSION: Speckle tracking echocardiography is feasible in 80% of adult patients with congenital heart disease and shows excellent intra- and inter-observer reproducibility.


Assuntos
Ecocardiografia/métodos , Técnicas de Imagem por Elasticidade/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Anormalidade Torcional/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Cardiopatias Congênitas/complicações , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Anormalidade Torcional/etiologia , Disfunção Ventricular Esquerda/etiologia
19.
Echocardiography ; 30(5): 558-63, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23228071

RESUMO

BACKGROUND: Tissue Doppler imaging (TDI) of the mitral annulus has been proposed as an alternative for the identification of hypertrophic cardiomyopathy (HCM) genetically affected subjects without left ventricular hypertrophy (G+/LVH-). Unfortunately, conflicting results have been described in the literature, potentially caused by the angle-dependency of TDI. This study sought to assess abnormalities in mitral annular velocities in G+/LVH- subjects as detected by speckle tracking echocardiography (STE). METHODS: The study population consisted of 23 consecutive genotyped family members without major or minor criteria for the diagnosis of HCM (mean age 37 ± 13 years, 9 men) and 23 healthy volunteers (age 38 ± 12 years, 12 men) who prospectively underwent STE. RESULTS: There were no significant differences in global peak systolic annular velocity (7.4 ± 1.2 vs. 7.1 ± 1.0 cm/sec) and early diastolic annular velocity (10.2 ± 2.5 vs. 11.3 ± 2.2 cm/sec) between G+/LVH- and control subjects. Global peak late diastolic annular velocity was higher in G+/LVH- subjects (8.1 ± 1.7 vs. 5.7 ± 1.1 cm/sec, P < 0.001). Regionally, this difference was seen in all 6 studied LV walls. CONCLUSIONS: This STE study confirms our previous TDI observations on increased peak late diastolic annular velocities in G+/LVH- subjects. Because of the complete overlap in early diastolic annular velocities this parameter cannot be used in the genotypes we studied to differentiate genotype (+) from genotype (-) individuals.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/genética , Heterozigoto , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Diástole/fisiologia , Ecocardiografia Doppler de Pulso/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Linhagem , Fenótipo , Estudos Prospectivos , Valores de Referência , Medição de Risco , Sístole/fisiologia , Disfunção Ventricular Esquerda/genética , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/genética
20.
Phys Ther ; 103(9)2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37265452

RESUMO

OBJECTIVE: Previously published results of the OPTICARE XL open label randomized controlled trial showed no added value of OPTICARE XL CR, a dedicated cardiac rehabilitation (CR) program for patients with obesity, with respect to health-related quality of life (primary outcome). This clinical trial studied the effects of OPTICARE XL CR on several secondary outcomes, which included body weight, physical activity, sedentary behavior, and physical fitness. METHODS: Patients with coronary artery disease or atrial fibrillation and body mass index ≥ 30 were randomized to OPTICARE XL CR (n = 102) or standard CR (n = 99). OPTICARE XL CR was a 1-year group intervention, specifically designed for patients with obesity that included aerobic and strength exercise, behavioral coaching, and an aftercare program. Standard CR consisted of a 6- to 12-week group aerobic exercise program, supplemented with cardiovascular lifestyle education. Study end points included body weight, physical activity, sedentary behavior (accelerometer), and physical fitness (6-Minute Walk Test and handgrip strength), which were evaluated 6 months after the end of CR (primary endpoint) and 3 months after the start of CR. RESULTS: Six months after completion of either program, improvements in body weight, physical activity, sedentary behavior, and physical fitness were similar between the groups. Three months after CR start, patients randomized to OPTICARE XL CR showed greater weight loss (mean change = -3.6 vs -1.8 kg) and a larger improvement in physical activity (+880 vs +481 steps per day) than patients randomized to standard CR. CONCLUSION: Patients allocated to OPTICARE XL CR lost significantly more body weight and showed promising results with respect to physical activity 3 months after the start of CR; however, these short-term results were not expanded or sustained in the longer term. IMPACT: Patients with obesity do not benefit from standard CR programs. The new OPTICARE XL CR program showed its effects in the short term on weight loss and physical activity, and, therefore, redesign of the aftercare phase is recommended.


Assuntos
Reabilitação Cardíaca , Humanos , Reabilitação Cardíaca/métodos , Comportamento Sedentário , Qualidade de Vida , Força da Mão , Exercício Físico , Obesidade , Peso Corporal , Aptidão Física , Redução de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA