Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Card Surg ; 37(1): 70-75, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34669217

RESUMO

OBJECTIVES: As aortic valve repair (AVr) for aortic insufficiency (AI) expands, minimally invasive (Mi) approaches are increasingly being applied. Cardiac surgical techniques can be more difficult through small incisions, and this report analyzes medium-term outcomes for MiAVr facilitated by geometric ring annuloplasty. METHODS: Since 2013, 58 patients were selected for AVr through upper sternotomy third-interspace incisions. The average age was 58.9 ± 15.4 (mean ± SD) years, 71% were male, and preoperative AI grade was 3.6 ± 0.8. Sixty-two percent (36/58) had a proximal aortic replacement for ascending aortic aneurysms (n = 26) and/or remodeling grafts for aortic root aneurysms (n = 10). Annuloplasty rings were placed subannularly (69% trileaflet; 31% bicuspid), and leaflet procedures were performed in 70%. The average ring diameter was 21.6 ± 1.4 mm, and the average aortic clamp time was 113 ± 35 min. RESULTS: After repair, AI grade fell to an average of 0.5 ± 0.6 (p < .0001), with a mean valve gradient of 12.5 ± 7.1 mmHg. No operative mortalities or major complications occurred. Three patients required reoperations for bleeding, and two had pacemakers. At an average follow-up of 38 months (maximal 88 months), three late deaths and no valve-related complications were observed. Four patients required reoperative aortic valve replacement over follow-up, and Kaplan-Meier survival and freedom from reoperation both exceeded 80% at 88 months. At the last follow-up, the average AI grade was 0.7 ± 0.7, and the mean valve gradient was 12.7 ± 6.3 mmHg. CONCLUSIONS: Geometric ring annuloplasty was safe and seemed to facilitate performing AVr ± proximal aortic replacement through Mi incisions. Hemodynamic improvements were significant, medium-term clinical outcomes were acceptable, and results could improve further with experience.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Adulto , Idoso , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Resultado do Tratamento
2.
J Surg Res ; 262: 21-26, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33530005

RESUMO

BACKGROUND: Previous reports of extracellular matrix (ECM) patch use after carotid endarterectomy (CEA) have noted an approximately 10% rate of pseudoaneurysm (PSA) formation. PSA-related rupture of ECM patches has also been described after femoral artery repair. In these studies, different thicknesses (4-ply versus 6-ply) and no standard length of soaking the patch in saline before implantation were used. Herein, we describe our experience with ECM CorMatrix patches in 291 CEAs with 6-ply patches. METHODS: The records of 275 consecutive patients undergoing 291 CEAs with CorMatrix 6-ply patches beginning in November of 2011 and extending until 2015 were reviewed. Only 6-ply patches and a 1 min hydration time in saline were used in all patients. No shunts were used. RESULTS: There were three deaths within the first 30 d secondary to subsequent cardiac surgical procedures. Nine patients experienced a perioperative stroke (3.1%), only one of which occurred secondary to an occluded internal carotid artery. One patient had a transient ischemic attack with a patent endarterectomy site. In follow-up, 11 patients (4.5%) developed severe recurrent stenoses requiring reintervention. Only one patient (0.34%) developed a PSA at 2 years possibly secondary to chronic infection. The median follow-up was 72 mo. CONCLUSIONS: Our experience with 6-ply CorMatrix ECM patches and a brief period of soaking demonstrated that these patches performed well in patients requiring a CEA. Only one PSA was noted.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Lesões das Artérias Carótidas/etiologia , Endarterectomia das Carótidas/efeitos adversos , Matriz Extracelular , Complicações Pós-Operatórias/etiologia , Idoso , Idoso de 80 Anos ou mais , Endarterectomia das Carótidas/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Card Surg ; 36(9): 3040-3051, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34118080

RESUMO

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic has had an unprecedented impact on health care and cardiac surgery. We report cardiac surgeons' concerns, perceptions, and responses during the COVID-19 pandemic. METHODS: A detailed survey was sent to recruit participating adult cardiac surgery centers in North America. Data regarding cardiac surgeons' perceptions and changes in practice were analyzed. RESULTS: Our study comprises 67 institutions with diverse geographic distribution across North America. Nurses were most likely to be redeployed (88%), followed by advanced care practitioners (69%), trainees (28%), and surgeons (25%). Examining surgeon concerns in regard to COVID-19, they were most worried with exposing their family to COVID-19 (81%), followed by contracting COVID-19 (68%), running out of personal protective equipment (PPE) (28%), and hospital resources (28%). In terms of PPE conservation strategies among users of N95 respirators, nearly half were recycling via decontamination with ultraviolet light (49%), followed by sterilization with heat (13%) and at home or with other modalities (13%). Reuse of N95 respirators for 1 day (22%), 1 week (21%) or 1 month (6%) was reported. There were differences in adoption of methods to conserve N95 respirators based on institutional pandemic phase and COVID-19 burden, with higher COVID-19 burden institutions more likely to resort to PPE conservation strategies. CONCLUSIONS: The present study demonstrates the impact of COVID-19 on North American cardiac surgeons. Our study should stimulate further discussions to identify optimal solutions to improve workforce preparedness for subsequent surges, as well as facilitate the navigation of future healthcare crises.


Assuntos
COVID-19 , Cirurgiões , Adulto , Descontaminação , Humanos , Pandemias , Percepção , SARS-CoV-2
4.
Am Heart J ; 227: 91-99, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32693197

RESUMO

Vitamin K antagonists are the only approved oral anticoagulants for long-term prophylaxis against valve thrombosis and thromboembolism in patients with a mechanical heart valve. Despite the proven efficacy and safety of anticoagulation with the oral direct factor Xa inhibitor apixaban compared with warfarin in high-risk populations including subjects with atrial fibrillation or with venous thromboembolism, it remains unknown whether patients with a mechanical heart valve can be safely managed with apixaban. The On-X Aortic Heart Valve and On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft may have lower rates of valve thrombosis and thromboembolism than conventional bileaflet and tilting disc valves due its unique pyrolytic carbon composition and flared inlet design. DESIGN: PROACT Xa is a randomized, multicenter, open-label, active-controlled trial comparing apixaban with warfarin in patients with an On-X Aortic Heart Valve or On-X Ascending Aortic Prosthesis with the Vascutek Gelweave Valsalva Graft. The study will randomize approximately 1,000 patients from approximately 60 sites in North America who underwent aortic valve replacement at least 3 months prior. Patients will be randomized 1:1 to receiving apixaban 5 mg twice daily or warfarin with a target international normalized ratio of 2.0-3.0. The last randomized participant will be followed for at least 2 years. The primary efficacy outcome is the composite of valve thrombosis and valve-related thromboembolism, and the primary safety outcome is major bleeding. Assuming the primary outcome occurs in warfarin-anticoagulated patients at a rate of 1.75%/patient-year, the study has more than 90% power to assess noninferiority of apixaban treatment with an absolute noninferiority margin of 1.75%/patient-year. A second co-primary analysis is to compare the hazard rate for the apixaban arm to twice the objective performance criterion for thromboembolism and valve thrombosis, that is, 3.4%/patient-year. SUMMARY: PROACT Xa will determine whether patients with an On-X Aortic Heart Valve can be anticoagulated with apixaban as an alternative to warfarin.


Assuntos
Anticoagulantes/uso terapêutico , Valva Aórtica/cirurgia , Inibidores do Fator Xa/uso terapêutico , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/prevenção & controle , Pirazóis/uso terapêutico , Piridonas/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto/métodos , Tromboembolia/prevenção & controle , Trombose/prevenção & controle , Varfarina/uso terapêutico , Anticoagulantes/efeitos adversos , Inibidores do Fator Xa/efeitos adversos , Humanos , Estudos Multicêntricos como Assunto , Desenho de Prótese , Pirazóis/efeitos adversos , Piridonas/efeitos adversos , Resultado do Tratamento , Varfarina/efeitos adversos
6.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38621698

RESUMO

OBJECTIVES: To assess if warfarin targeted to international normalized ratio (INR) 1.8 (range 1.5-2.0) is safe for all patients with an On-X aortic mechanical valve. METHODS: This prospective, observational registry follows patients receiving warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus daily aspirin (75-100 mg) after On-X aortic valve replacement. The primary end point is a composite of thromboembolism, valve thrombosis and major bleeding. Secondary end points include the individual rates of thromboembolism, valve thrombosis and major bleeding, as well as the composite in subgroups of home or clinic-monitored INR and risk categorization for thromboembolism. The control was the patient group randomized to standard-dose warfarin (INR 2.0-3.0) plus daily aspirin 81 mg from the PROACT trial. RESULTS: A total of 510 patients were enroled at 23 centres in the UK, USA and Canada. Currently, the median follow-up duration is 3.4 years, and median achieved INR is 1.9. The primary composite end point rate in the low INR patients is 2.31% vs 5.39% (95% confidence interval 4.12-6.93%) per patient-year in the PROACT control group, constituting a 57% reduction. Results are consistent in subgroups of home or clinic-monitored, and high-risk patients, with reductions of 56%, 57% and 57%, respectively. Major and total bleeding are decreased by 85% and 73%, respectively, with similar rates of thromboembolic events. No valve thrombosis occurred. CONCLUSIONS: Interim results suggest that warfarin targeted at an INR of 1.8 (range 1.5-2.0) plus aspirin is safe and effective in patients with an On-X aortic mechanical valve with or without home INR monitoring.


Assuntos
Anticoagulantes , Valva Aórtica , Aspirina , Implante de Prótese de Valva Cardíaca , Coeficiente Internacional Normatizado , Tromboembolia , Varfarina , Humanos , Varfarina/administração & dosagem , Varfarina/efeitos adversos , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Masculino , Feminino , Valva Aórtica/cirurgia , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Estudos Prospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Tromboembolia/prevenção & controle , Tromboembolia/etiologia , Pessoa de Meia-Idade , Próteses Valvulares Cardíacas/efeitos adversos , Trombose/prevenção & controle , Trombose/etiologia , Hemorragia/induzido quimicamente
7.
Artigo em Inglês | MEDLINE | ID: mdl-38688451

RESUMO

OBJECTIVES: To evaluate whether warfarin targeted at an international normalized ratio of 1.8 (range, 1.5-2.0) after On-X mechanical aortic valve implant is safe for all patients. METHODS: This prospective, observational clinical registry assessed adverse event rates in adult patients receiving low-dose warfarin (target international normalized ratio, 1.8; range, 1.5-2.0) plus daily aspirin (75-100 mg) during a 5-year period after On-X aortic valve implant. The primary end point is the combined rate of major bleeding, valve thrombosis, and thromboembolism overall and in 4 subgroups. The comparator is the Prospective Randomized On-X Anticoagulation Trial control group patients on standard-dose warfarin (international normalized ratio, 2.0-3.0) plus aspirin 81 milligrams daily. RESULTS: A total of 510 patients were recruited at 23 centers in the United States, United Kingdom, and Canada between November 2015 and January 2022. This interim analysis includes 229 patients scheduled to complete 5-year follow-up by August 16, 2023. The linearized occurrence rate (in percent per patient-year) of the primary composite end point of major bleeding, valve thrombosis, and thromboembolism is 1.83% compared with 5.39% (95% confidence interval, 4.12%-6.93%) in the comparator group. Results are consistent in clinic-monitored and home-monitored patients and in those at high risk for thromboembolism. Major bleeding and total bleeding were reduced by 87% and 71%, respectively, versus the comparator group, without an increase in thromboembolic events. CONCLUSIONS: Interim results support the continued safety of the On-X aortic mechanical valve with a target international normalized ratio of 1.8 plus low-dose aspirin through 5 years after implant, with or without home monitoring.

8.
JTCVS Open ; 14: 205-213, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37425466

RESUMO

Despite the benefits established for multiple surgical specialties, enhanced recovery after surgery has been underused in cardiac surgery. A cardiac enhanced recovery after surgery summit was convened at the 102nd American Association for Thoracic Surgery annual meeting in May 2022 for experts to convey key enhanced recovery after surgery concepts, best practices, and applicable results for cardiac surgery. Topics included implementation of enhanced recovery after surgery, prehabilitation and nutrition, rigid sternal fixation, goal-directed therapy, and multimodal pain management.

9.
Ann Thorac Surg ; 115(4): 929-938, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36610532

RESUMO

BACKGROUND: Current guidelines recommend a target international normalized ratio (INR) range of 2.5 to 3.5 in patients with a mechanical mitral prosthesis. The Prospective Randomized On-X Anticoagulation Clinical Trial (PROACT) Mitral randomized controlled noninferiority trial assessed safety and efficacy of warfarin at doses lower than currently recommended in patients with an On-X (Artivion, Inc) mechanical mitral valve. METHODS: After On-X mechanical mitral valve replacement, followed by at least 3 months of standard anticoagulation, 401 patients at 44 North American centers were randomized to low-dose warfarin (target INR, 2.0-2.5) or standard-dose warfarin (target INR, 2.5-3.5). All patients were prescribed aspirin, 81 mg daily, and encouraged to use home INR testing. The primary end point was the sum of the linearized rates of thromboembolism, valve thrombosis, and bleeding events. The design was based on an expected 7.3% event rate and 1.5% noninferiority margin. RESULTS: Mean patient follow-up was 4.1 years. Mean INR was 2.47 and 2.92 (P <.001) in the low-dose and standard-dose warfarin groups, respectively. Primary end point rates were 11.9% per patient-year in the low-dose group and 12.0% per patient-year in the standard-dose group (difference, -0.07%; 95% CI, -3.40% to 3.26%). The CI >1.5%, thus noninferiority was not achieved. Rates (percentage per patient-year) of the individual components of the primary end point were 2.3% vs 2.5% for thromboembolism, 0.5% vs 0.5% for valve thrombosis, and 9.13% vs 9.04% for bleeding. CONCLUSIONS: Compared with standard-dose warfarin, low-dose warfarin did not achieve noninferiority for the composite primary end point. (PROACT Clinicaltrials.gov number, NCT00291525).


Assuntos
Implante de Prótese de Valva Cardíaca , Tromboembolia , Trombose , Humanos , Varfarina/efeitos adversos , Anticoagulantes/efeitos adversos , Estudos Prospectivos , Valva Mitral/cirurgia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Hemorragia/etiologia , Trombose/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos
10.
Prog Cardiovasc Dis ; 72: 31-40, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35738422

RESUMO

Patients who need a prosthetic aortic heart valve may decide, working with their cardiologist and cardiac surgeon, among a variety of options: surgical or transcatheter approach, bioprosthetic or mechanical valve, or a Ross procedure if suitable to their age and anatomy. This review article examines the evidence for survival benefit with mechanical aortic valves, discusses bioprosthetic structural valve degeneration and its consequences, and considers the risks of redo aortic valve surgery or subsequent valve-in-valve (ViV) transcatheter intervention. It highlights the unique characteristics of the On-X aortic valve, including the US Food and Drug Administration approved and American College of Cardiology/American Heart Association guideline supported reduced anticoagulation target INR of 1.5 to 2.0, and discusses the PROACT Xa trial comparing apixaban vs warfarin anticoagulation. The choice of prosthetic valve should be individualized, carefully considering each patient's unique circumstances. In that context, the On-X aortic valve offers a potential lifetime solution without need for a repeat operation, while minimizing the risks of long-term anticoagulation. In an era of enthusiasm for bioprosthetic and transcatheter-based approaches, the option of a second-generation bileaflet mechanical valve with optimized hemodynamics-the On-X aortic valve-may well align with patient expectations.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Anticoagulantes/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Ann Thorac Surg ; 113(3): e183-e185, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34102172

RESUMO

Early and late outcomes of patients undergoing multiple-valve procedures are better if all valves are repaired. Aortic/mitral multiple-valve repair has been limited by an inability to repair the more complex forms of aortic valve insufficiency. With the development of aortic ring annuloplasty 90% to 95% of aortic valve insufficiency pathologies now can be repaired, which opens most aortic/mitral multiple-valve procedures to the better repair outcomes. This report illustrates 4 cases of aortic/mitral ± tricuspid valve disease managed by multiple-valve repair.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/cirurgia
12.
Innovations (Phila) ; 17(6): 463-470, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36373654

RESUMO

OBJECTIVE: Patients with elevated CHA2DS2-VASc scores are at high risk for atrial fibrillation (AF) and thromboembolic events (TE) after cardiac surgery. Left atrial appendage exclusion (LAAE) is a permanent, continuous approach to stroke prevention in AF, overcoming limitations of oral anticoagulation (OAC). We report ATLAS trial results focused on LAAE technical success and perioperative safety and TE rates with and without LAAE in cardiac surgery patients who developed postoperative AF (POAF). METHODS: ATLAS (NCT02701062) was a prospective, multicenter, feasibility trial. Patients age ≥18 years, undergoing structural heart procedure, with no preoperative AF, CHA2DS2-VASc ≥2, and HAS-BLED ≥2 were randomized 2:1 to LAAE or no LAAE. Patients who developed POAF and/or received LAAE were followed for 1 year. LAAE was evaluated with intraoperative transesophageal echocardiography. RESULTS: A total of 562 patients were randomized to LAAE (n = 376) or no LAAE (n = 186). Mean CHA2DS2-VASc (3.4 vs 3.4) and HAS-BLED (2.8 vs 2.9) scores were similar for LAAE and no LAAE groups. LAAE success (no flow nor residual stump >10 mm) was 99%. One LAAE-related serious adverse event (0.27%) occurred and was resolved without sequelae. There were 44.3% of patients who developed POAF. Through 1 year, 3.4% of LAAE patients and 5.6% of no LAAE patients had TE. OAC was used by 32.5% of POAF patients. Bleeding was higher with OAC than without (16.1% vs 5.4%, P = 0.008). CONCLUSIONS: ATLAS demonstrated a high rate of successful LAAE with low LAAE-related serious adverse events in cardiac surgery patients. Study results should be considered in future trial design to further evaluate prophylactic LAAE for stroke prevention in cardiac surgery patients with elevated stroke risk.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Acidente Vascular Cerebral , Humanos , Adolescente , Fatores de Risco , Medição de Risco/métodos , Apêndice Atrial/cirurgia , Estudos Prospectivos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Hemorragia/complicações , Fibrilação Atrial/cirurgia
13.
JTCVS Tech ; 14: 55-65, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35967205

RESUMO

Objectives: Geometric ring annuloplasty has shown promise during bicuspid aortic valve repair for aortic insufficiency. This study examined early outcomes of bicuspid aortic valve repair associated with proximal aortic aneurysm replacement. Methods: From September 2017 to November, 2021, 127 patients underwent bicuspid aortic valve repair with concomitant proximal aneurysm reconstruction. Patient age was 50.6 ± 12.7 years (mean ± standard deviation), male gender was 83%, New York Heart Association Class was 2 (1-2) (median [interquartile range]), and preoperative aortic insufficiency grade was 3 (2-4). Ascending aortic diameter was 50 (46-54) mm, and all patients had ascending aortic replacement. Forty patients had sinus diameters greater than 45 mm, prompting remodeling root procedures. A total of 105 patients had Sievers type 1 valves, 3 patients had type 0, and 7 patients had type 2. A total of 118 patients had primarily right/left fusion, 8 patients had right/nonfusion, and 1 patient had left/nonfusion. Leaflet reconstruction used central leaflet plication and cleft closure, with limited ultrasonic decalcification in 31 patients. Results: Ring size was 23 (21-23) mm, and 26 of 40 root procedures were selective nonfused sinus replacements. Aortic clamp time was 139 (112-170) minutes, and bypass time was 178 (138-217) minutes. Postrepair aortic insufficiency grade was 0 (0-0) (P < .0001), and mean valve gradient was 10 (7-14) mm Hg. No early and 1 late mortality occurred. Four patients required reoperation for bleeding, and 4 patients required pacemakers. At a mean follow-up of 20 months (maximal 93), there were no valve-related complications, 5 late repair failures prompting valve replacement, and 1 death due to Coronavirus Disease 2019. Conclusions: Geometric ring annuloplasty for bicuspid aortic valve repair with proximal aortic aneurysm reconstruction is safe and associated with good early outcomes. Further experience and follow-up will help inform long-term durability.

14.
Innovations (Phila) ; 17(1): 42-49, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35225065

RESUMO

OBJECTIVE: Up to 28% of patients may need mitral valve (MV) surgery after transcatheter edge-to-edge repair (TEER). This study evaluates the outcomes of minimally invasive MV surgery after TEER. Methods: International multicenter registry of minimally invasive MV surgery after TEER between 2013 and 2020. Subgroups were stratified by the number of devices implanted (≤1 vs >1), as well as time interval from TEER to surgery (≤1 year vs >1 year). Results: A total of 56 patients across 13 centers were included with a mean age of 73 ± 11 years, and 50% were female. The median Society of Thoracic Surgeons Predicted Risk of Mortality (STS PROM) score for MV replacement was 8% (Q1-Q3 = 5% to 11%) and the ratio of observed to expected mortality was 0.9. The etiology of mitral regurgitation (MR) prior to TEER was primary MR in 75% of patients and secondary MR in 25%. There were 30 patients (54%) who had >1 device implanted. The median time between TEER and surgery was 252 days (33 to 636 days). Hemodynamics, including MR severity, MV area, and mean gradient, significantly improved after minimally invasive surgery and sustained to 1-year follow-up. In-hospital and 30-day mortality was 7.1%, and 1-year actuarial survival was 85.6% ± 6%. Conclusions: Minimally invasive MV surgery after TEER may be achieved as predicted by the STS PROM. Most patients underwent MV replacement instead of repair. As TEER is applied more widely, patients should be informed about the potential need for surgical intervention over time after TEER. These discussions will allow better informed consent and post-procedure planning.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Sistema de Registros , Resultado do Tratamento
15.
Ann Thorac Surg ; 2022 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-35101419

RESUMO

This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/our-business/policies/article-withdrawal.

16.
Ann Thorac Surg ; 111(4): 1359-1366, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32619617

RESUMO

BACKGROUND: Unicuspid aortic valves (Sievers type 2 bicuspid) are characterized by major fusion and clefting of the right-left coronary commissure, and minor fusion of the right-noncoronary commissure. Repair has been difficult because of two fusions, variable relative sinus sizes, and peripheral leaflet deficiencies or tears after balloon valvuloplasty. METHODS: Twenty unicuspid aortic valves patients underwent valve repair in nine institutions. Right-left major fusion and right-noncoronary minor fusion occurred in 17 of 20 (85%). Commissurotomy was performed on the minor fusion, and a bicuspid annuloplasty ring with circular base geometry and two 180-degree subcommissural posts was sutured beneath the annulus, equalizing the annular circumferences of the fused and nonfused cusps. The nonfused leaflet was plicated, and the cleft in the major fusion was closed linearly until leaflet effective heights and lengths became greater than 8 mm and equal, respectively. RESULTS: Average age (mean ± SD) was 22.3 ± 12.3 years (range, 13 to 58), 12 of 20 (60%) were symptomatic, 10 of 20 (50%) required aortic aneurysm resection. Pre-repair hemodynamic data included mean systolic valve gradient 25.8 ± 12.9 mm Hg, aortic insufficiency grade 2.9 ± 1.2, and annular diameter 24.7 ± 3.3 mm. No mortality or major complications occurred. Post-repair annular (ring) size was 20.5 ± 1.3 mm, mean gradient fell to 16.2 ± 5.9 mm Hg, and aortic insufficiency grade decreased to 0.1 ± 0.3 (P < .001). At an average follow-up of 11 months (range, 1 to 22), all 20 patients were asymptomatic and had returned to full activity. CONCLUSIONS: Aortic ring annuloplasty reduced annular diameter effectively, recruiting more leaflet to midline coaptation. Minor fusion commissurotomy and annular remodeling to 180-degree commissures converted UAV repair to a simple and reproducible procedure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Adolescente , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Anuloplastia da Valva Cardíaca/métodos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Adulto Jovem
17.
Ann Thorac Surg ; 109(1): e33-e35, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31181203

RESUMO

This video demonstrates aortic valve repair during ascending aneurysm replacement for a 71-year-old man with congestive heart failure, grade 3 aortic insufficiency, and a 5.4-cm ascending aneurysm. On testing, the noncoronary leaflet is prolapsing, the annulus is 27 mm, and the leaflets size to a 21-mm ring. The ring is sutured beneath the aortic valve annulus with nine horizontal mattress sutures. The noncoronary leaflet is plicated, correcting the prolapse. A 28-mm Dacron tube graft (Maquet Hemashield, Baden-Württemberg, Germany) is sutured to the supracoronary and distal aorta. After repair, aortic insufficiency is trivial with a mean systolic gradient of 9 mm Hg. The patient recovered uneventfully.


Assuntos
Aneurisma Aórtico/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/métodos , Idoso , Aneurisma Aórtico/complicações , Insuficiência da Valva Aórtica/complicações , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Masculino , Técnicas de Sutura , Procedimentos Cirúrgicos Vasculares/métodos
18.
Crit Care Clin ; 36(4): 617-630, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32892817

RESUMO

Enhanced recovery after surgery (ERAS) protocols recognize early postoperative mobilization as a driver of faster postoperative recovery, return to normal activities, and improved long-term patient outcomes. For patients undergoing open cardiac surgery, an opportunity for facilitating earlier mobilization and a return to normal activity lies in the use of improved techniques to stabilize the sternal osteotomy. By following the key orthopedic principles of approximation, compression, and rigid fixation, a more nuanced approach to sternal precaution protocols is possible, which may enable earlier patient mobilization, physical rehabilitation, and recovery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Esternotomia , Placas Ósseas , Fios Ortopédicos , Humanos , Esterno , Resultado do Tratamento
19.
Ann Thorac Surg ; 117(6): 1176-1177, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38608745
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA