1.
Medicina (Kaunas) ; 60(8)2024 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-39202575

RESUMO

Background and Objectives: Patients with atrial fibrillation and coronary artery disease represent a group with a greater risk of mortality. To evaluate patients with atrial fibrillation (AF) and a significant coronary bifurcation lesion and compare the clinical outcomes between the patients on anticoagulant treatment with Vitamin K antagonist (VKA) and those on direct anticoagulant (DOAC). Materials and Methods: This is a prospective study of patients with AF and stable coronary artery disease, who had evidence of a significant coronary bifurcation lesion. A log-rank test was used to assess the difference in mortality between patients taking VKA and those on DOAC. The primary endpoint was the incidence of all-cause and cardiovascular death at mid-term. Results: A total of 226 patients with AF and a significant bifurcation lesion were included. The mean age was 70.9 ± 9.2, and 70% were males. Of the patients, 123 (54.7%) were on VKA treatment, and 103 (45.3%) were taking DOAC. For a median follow-up time of 55 (39-96) months, overall mortality was 40%, whereas CV mortality was 31%. Both all-cause (28.2% versus 50.4%, p = 0.020) and CV death (12.7% versus 24.9%, p = 0.032) were significantly lower in patients taking DOAC versus those on VKA. In patients treated with PCI, CV mortality was significantly lower in patients taking DOAC (21.4% versus 40.5%, p = 0.032). VKA therapy was an independent predictor of cardiovascular death (HR 1.88; 95% CI 1.11-3.18; p = 0.01), together with chronic kidney disease (HR 1.81; 95% CI 1.13-2.92; p = 0.01). Conclusions: Treatment with DOAC in patients with atrial fibrillation and coronary bifurcation lesion was associated with significantly lower mortality independently of the treatment approach. VKA was an independent predictor of CV mortality.


Assuntos
Anticoagulantes , Fibrilação Atrial , Doença da Artéria Coronariana , Sistema de Registros , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/complicações , Masculino , Feminino , Idoso , Anticoagulantes/uso terapêutico , Estudos Prospectivos , Sistema de Registros/estatística & dados numéricos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/complicações , Bulgária/epidemiologia , Vitamina K/antagonistas & inibidores , Resultado do Tratamento
2.
Rev Cardiovasc Med ; 23(12): 393, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-39076651

RESUMO

Background: Recently, we have observed an increasing focus on myocardial infarction (MI) with non-obstructive coronary arteries (MINOCA) patients. MINOCA incidence is estimated to be within the range of 5-15% of all MI cases. Unfortunately, MINOCA relates to various conditions that are not rarely hard to identify, including coronary microcirculation dysfunction, epicardial coronary spasm, or plaque erosion. Our systematic review aimed to identify and appraise previous studies which characterized acute complications, with particular focus on mechanical complications, in patients with MINOCA. Methods: Applying the MeSH strategy in PubMed and Embase, two operators independently and systematically reviewed published studies on patients diagnosed with MINOCA and in whom acute complications were described. Papers published in the last 10 years (June 2012-June 2022) to reflect the introduction of the MINOCA definition as well as the current clinical practice were analyzed. The research was conducted in July 2022. Results: The search yielded 192 records. After abstract review, 79 papers were left, and after full-text analysis, we finally included 20 studies. Among 20 studies, there were: one randomized controlled trial, one prospective study, five retrospective studies, 1 case series, and 12 case reports with a total number of 337,385 patients. In the identified literature, we revealed 7 cases of intraventricular septal rupture, 3 cases of free wall rupture with pericardial effusion or cardiac tamponade, and 3 cases of bleeding complications (intracerebral or intestinal bleeding). Moreover, the ventricular arrhythmia incidence ranged from 2% to 13.8%, and the in-hospital death rate ranged from 0.9% to 6.4%. Conclusions: These findings suggest that MINOCA patients should be treated as standard MI patients with watchful monitoring, especially in the first few days.

3.
Catheter Cardiovasc Interv ; 99(6): 1723-1732, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35318789

RESUMO

BACKGROUND: Low operator and institutional volume are associated with poorer procedural and long-term clinical outcomes in the general population of patients treated with percutaneous coronary interventions (PCI). AIM: To assess the relationship between operator experience and procedural outcomes of patients treated with PCI and rotational atherectomy (RA). METHODS: Data for conducting the current analysis were obtained from the national registry of percutaneous coronary interventions (ORPKI) maintained in cooperation with the Association of Cardiovascular Interventions (AISN) of the Polish Cardiac Society. The study covers data from January 2014 to December 2020. RESULTS: During the investigated period, there were 162 active CathLabs, at which 747,033 PCI procedures were performed by 851 operators (377 RA operators [44.3%]). Of those, 5188 were PCI with RA procedures; average 30 ± 61 per site/7 years (Me: 3; Q1-Q3: 0-31); 6 ± 18 per operator/7 years (Me: 0; Q1-Q3: 0-3). Considering the number of RA procedures annually performed by individual operators during the analyzed 7 years, the first quartile totaled (Q1: < =2.57), the second (Q2: < =5.57), and the third (Q3: < =11.57), while the fourth quartile was (Q4: > 11.57). The maximum number of procedures was 39.86 annually per operator. We demonstrated, through a nonlinear relationship with annualized operator volume and risk-adjusted, that operators performing more PCI with RA per year (fourth quartile) have a lower number of the overall periprocedural complications (p = 0.019). CONCLUSIONS: High-volume RA operators are related to lower overall periprocedural complication occurrence in patients treated with RA in comparison to low-volume operators.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Aterectomia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etiologia , Doença da Artéria Coronariana/terapia , Mortalidade Hospitalar , Hospitais com Alto Volume de Atendimentos , Hospitais com Baixo Volume de Atendimentos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Resultado do Tratamento
4.
Eur J Clin Invest ; 51(8): e13555, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33782985

RESUMO

BACKGROUND: The wide variation in bifurcation anatomy has generated an ongoing search for stents explicitly designed for coronary bifurcations, and to date, results have been underachieved. METHODS: The POLBOS I and POLBOS II were international, multicentre, randomized, open-label, controlled trials. Patients were randomly assigned to BiOSS Expert (in POLBOS I, biodegradable polymer eluting paclitaxel)/BiOSS LIM (in POLBOS II, biodegradable polymer eluting sirolimus) stent implantation or regular drug-eluting stent (rDES) deployment. A provisional T-stenting strategy was the default treatment option. The primary endpoint of this pooled data study was the cumulative rate of major adverse cardiovascular events (MACE) consisting of cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). Telephone follow-up was performed annually up to 72 months. (ClinicalTrials.gov Identifier: POLBOS I-NCT02192840, POLBOS II-NCT02198300). RESULTS: The total study population consisted of 445 patients, 222 patients in the BiOSS group and 223 patients in the rDES group. The follow-up rate was 93.7% in the BiOSS group and 91.9% in the rDES group. At 72 months, there was no significant difference between BiOSS and rDES groups regarding MACE (25.7% vs 25.1%, HR 1.06, 95% CI 0.73-1.52), cardiac death (3.1% vs 4.0%, HR 0.94, 95% CI 0.43-2.34), MI (3.6% vs 4.9%, HR 0.76, 95% CI 0.32-2.89), TLR (18.9% vs 16.1%, HR 1.17, 95% CI 0.75-1.83) and stent thrombosis rates (0.9% vs 0.5%, HR 1.21, 95CI 0.75-2.09). CONCLUSIONS: At the 6-year follow-up, clinically significant clinical events did not differ between BiOSS stents and rDES.


Assuntos
Implantes Absorvíveis , Vasos Coronários/patologia , Stents Farmacológicos , Idoso , Stents Farmacológicos/classificação , Feminino , Cardiopatias , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Sirolimo/uso terapêutico
5.
Wiad Lek ; 74(7): 1622-1627, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34459762

RESUMO

OBJECTIVE: The aim: We aimed to assess the feasibility and safety of performing balloon aortic valvuloplasty (BAV) with Valver balloon catheter (Balton, Poland) in adults with severe aortic stenosis as a bridge or palliative treatment. PATIENTS AND METHODS: Materials and methods: We identified consecutive patients who underwent BAV procedures between May 2019 and March 2020 using Valver balloon catheters. Demographic data, medical history, and clinical characteristics were retrospectively collected in all study patients together with periprocedural data as well as 12-month follow-up data. RESULTS: Results: We included 18 patients. The mean population age was 78.1±8.9 years, and women were 61.1%. The most common co-morbidities were arterial hypertension (88.9%), dyslipidemia (83.3%), and coronary artery disease (72.2%). The baseline mean aortic valve pressure gradient was 49.94±27.02 mmHg and the mean aortic valve area (AVA) was 0.65±0.20 cm2. In all cases, the procedure was performed from the femoral access via the 8F sheath. Two Valver balloon catheter sizes were used 18x40mm (33.3%) and 20x40mm (66.7%). Three periprocedural complications were observed, and none was associated with the Valver balloon catheter per se. The transthoracic echocardiography after the procedure revealed a decrease in the mean pressure gradient of 11.1±8.85 mmHg, and an increase in AVA of 0.21±0.19 cm2. At 12-month follow-up, the mortality rate was 38.9%. CONCLUSION: Conclusions: BAV is a procedure increasingly performed in catheterization laboratories worldwide. This paper confirmed the relative safety of BAV with Valver balloon catheters in the modern era, showing a low incidence of valve and vascular complications.


Assuntos
Estenose da Valva Aórtica , Cuidados Paliativos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Catéteres , Feminino , Humanos , Estudos Retrospectivos , Resultado do Tratamento
6.
Lancet ; 393(10175): 987-997, 2019 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-30827782

RESUMO

BACKGROUND: Supraflex is a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts. We aimed to compare Supraflex with the standard of care, Xience, an everolimus-eluting stent with a durable polymer coating, regarding clinical outcomes with a randomised trial in an all-comer population. METHODS: We did a prospective, randomised, single-blind, multicentre study (TALENT) across 23 centres in Europe (the Netherlands, Poland, the UK, Spain, Bulgaria, Hungary, and Italy). Eligible participants were aged 18 years or older, had one or more coronary artery stenosis of 50% or greater in a native coronary artery, saphenous venous graft, or arterial bypass conduit, and had a reference vessel diameter of 2·25-4·50 mm. Patients underwent percutaneous coronary intervention in an all-comer manner. We randomly assigned patients (1:1) to implantation of either a sirolimus-eluting stent with a biodegradable polymer coating and ultra-thin struts (Supraflex) or an everolimus-eluting stent with a durable polymer coating (Xience). Randomisation was done by local investigators by use of a web-based software with random blocks according to centre. The primary endpoint was a non-inferiority comparison of a device-oriented composite endpoint-cardiac death, target-vessel myocardial infarction, or clinically indicated target lesion revascularisation-between groups at 12 months after the procedure, assessed in an intention-to-treat population. On assumption of 1-year composite endpoint prevalence of 8·3%, a margin of 4·0% was defined for non-inferiority of the Supraflex group compared with the Xience group. This trial is registered with ClinicalTrials.gov, number NCT02870140. FINDINGS: Between Oct 21, 2016, and July 3, 2017, 1435 patients with 1046 lesions were randomly assigned to Supraflex, of whom 720 received the index procedure, and 715 patients with 1030 lesions were assigned to Xience, all receiving the index procedure. At 12 months, the primary endpoint had occurred in 35 patients (4·9 %) in the Supraflex group and in 37 patients (5·3%) in the Xience group (absolute difference -0·3% [one-sided 95% upper confidence bound 1·6%], pnon-inferiority<0·0001). Definite or probable stent thrombosis prevalence, a safety indicator, was low in both groups and did not differ between them. INTERPRETATION: The Supraflex stent was non-inferior to the Xience stent for a device-oriented composite clinical endpoint at 12 months in an all-comer population. Supraflex seems a safe and effective alternative drug-eluting stent to other stents in clinical practice. FUNDING: European Cardiovascular Research Institute.


Assuntos
Aterosclerose/terapia , Stents Farmacológicos , Everolimo/administração & dosagem , Imunossupressores/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Stents Farmacológicos/efeitos adversos , Determinação de Ponto Final , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Trombose/etiologia
7.
Catheter Cardiovasc Interv ; 96(1): E84-E92, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32150341

RESUMO

OBJECTIVES: To define the impact of side branch (SB) lesion length on clinical outcomes after percutaneous coronary intervention (PCI) on bifurcation lesions. BACKGROUND: The role of the SB lesion length remains questionable in PCI planning and its implication on clinical outcome is controversial. METHODS: Data from the retrospective multicenter EBC-P2BiTO registry were analyzed. The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction excluding periprocedural, or stent thrombosis at 13 months median follow-up (IQR 11-28). By using propensity scores for inverse probability of treatment weighting (IPTW), the comparison of treatment groups was adjusted to correct for potential confounding. RESULTS: Among 1,252 patients, SB was normal in 489 (39%), diseased in 763 (61%) cases. MACE occurred in 68 patients (5.4%). The optimal discriminant SB lesion length for MACE was ≥10 mm, with an area under the curve of 0.71 (p < .01). The incidence of MACE was higher among patients with SB lesions ≥10 mm (8%) than with normal SB (4.1%) (hazard ratio [HR], 2.8; 95% confidence interval [CI], 1.5-5.3; p = .001, IPTW-adjusted) or SB lesions <10 mm (5.1%) (HR, 1.5; 95% CI, 1.1-3.3; p = .048, IPTW-adjusted), being similar between these last two groups. CONCLUSIONS: In bifurcation PCI, SB lesion length ≥ 10 mm identifies patients at higher risk of MACE than those with <10 mm SB lesions and those without SB disease, considering that no differences were observed among these last two groups. Careful planning is mandatory when approaching bifurcations with long SB lesions.


Assuntos
Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
Wiad Lek ; 73(7): 1580-1582, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32759458

RESUMO

Penetrating aortic ulcer (PAU) is ulceration of an aortic atherosclerotic plaque penetrating through the internal lamina into the media. PAU is a rare condition and occurs in 2% - 7% of acute aortic syndromes (AAS); however, the actual incidence is unknown because of asymptomatic patients. One may treat it conservatively as well as surgically. We present a case of a 54-year-old man, who was admitted to hospital due to the exaggeration of exertional chest pain and persistent headaches. During coronary angiography, the suspicion of PAU was raised. Contrast-enhanced computed tomography confirmed the diagnosis. Transesophageal echocardiography showed bicuspid aortic valve with minimal calcification, the dilated ascending aorta, large atherosclerotic plaques in the aortic arch with ulceration (thickness: 5.0 - 5.5mm, diameter: 5 - 6 mm, depth: 3 - 4 mm), without intramural hematoma. Conservative treatment was chosen with uneventful 2-year follow-up. Although surgical management is advocated for patients with PAU type A, we demonstrated that type A PAU can be successfully treated conservatively as well.


Assuntos
Aorta Torácica , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas , Úlcera , Aorta , Doença da Válvula Aórtica Bicúspide , Tratamento Conservador , Humanos , Masculino , Pessoa de Meia-Idade
9.
Catheter Cardiovasc Interv ; 92(2): 302-309, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29027737

RESUMO

OBJECTIVES: The aim of the study was to capture the evolution of neointima after implantation of a biodegradable polymer-coated, sirolimus-eluting, cobalt-chromium coronary stent system (BP-DES). BACKGROUND: Optical coherence tomography (OCT) suggests that in-stent neointimal morphology influences clinical outcomes after DES implantation. METHODS: Sixty patients treated with single BP-DES implantation were examined by quantitative coronary angiography (QCA) and OCT at 3, 6, and 12-month follow-up. RESULTS: Median late lumen loss by QCA (mm) was 0.04 (IQR 0, 0.08), 0.17 (IQR 0, 0.32), and 0.14 (IQR 0.07, 0.31) at 3, 6, and 12-month follow-up respectively (P = 0.03). OCT cross-section multilevel analysis showed uncovered struts in 3.90%, 1.78%, and 0.02% of struts respectively (P = 0.03). The corresponding malapposition rates were 0.12%, 0.04%, and 0%. Lipid-rich neointima was observed only at 12-month follow-up in one restenotic lesion (0.77% cross-sections) that was accountable for the only target vessel revascularization. The homogeneous pattern was prevalent at all three time points, but its incidence displayed an upward trend (3 months: 59%; 6 months: 71%; 12 months: 88%) despite no difference in neointimal volume between 6 and 12 months. Conversely, a trend could be observed of decreasing incidence of heterogeneous pattern as the follow-up length increased. CONCLUSIONS: In this study of a single-type BP-DES, the majority of stent struts were covered within 3 months from implantation. While the quantitative neointimal accumulation plateaued at 6 months with no further significant increase beyond 6 months, the neointima continued to evolve qualitatively and mature along with better strut coverage between 6 and 12 months after implantation.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Stents Farmacológicos , Neointima , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Idoso , Fármacos Cardiovasculares/efeitos adversos , Ligas de Cromo , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Polônia , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
10.
J Interv Cardiol ; 31(5): 599-607, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29869380

RESUMO

OBJECTIVES: We evaluated the impact of stent inflation pressure and type of guidewire on "jailed" coronary guidewire damage occurring during bifurcation angioplasty. BACKGROUND: Despite new techniques and treatment options during percutaneous coronary intervention (PCI) we still observe peri- and postoperative complications for to various known and unknown reasons. METHODS: Patients undergoing PCI within the coronary bifurcation were randomly assigned to one of four groups: Pilot 50 or BMW guidewire and pressure ≤12 or >12 atm. After PCI each "jailed" guidewire was evaluated under an optical microscope. The Wide Beast Scale (WBS) was developed for the internal purposes of the study and was used for qualitative assessment. Also, the inflation pressure, the patients' characteristics and the technical parameters of the procedure were recorded. RESULTS: The clinical characteristics were similar in all the groups. There was no statistical significance of the degree of damage, rated on the WBS, for either guidewire group with respect to inflation pressure (P = 0.49). The prevalence of guidewire damage was higher in the BMW versus the Pilot 50 group (98.4% vs 67.4% respectively, P = 0.00001) as was the severity of the damage (grades 3 and 4) in BMW versus Pilot 50 (55.6% vs 13.0% respectively, P = 0.00001). CONCLUSIONS: The inflation pressure during stent implantation had no impact on "jailed" guidewire damage. The difference in the prevalence of serious damage and total damage number was statistically significant for the BMW guidewire compared to the Pilot50. The BMW guidewire was an independent predictor of the degree of damage to the guidewire.


Assuntos
Implante de Prótese Vascular , Angiografia Coronária , Vasos Coronários/lesões , Complicações Intraoperatórias , Stents/efeitos adversos , Lesões do Sistema Vascular , Idoso , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/instrumentação , Angiografia Coronária/métodos , Análise de Falha de Equipamento , Feminino , Humanos , Incidência , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Lesões do Sistema Vascular/epidemiologia , Lesões do Sistema Vascular/etiologia
11.
Eur J Clin Invest ; 47(7): 524-530, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28555728

RESUMO

BACKGROUND: Mean platelet volume (MPV) was proved to be a reliable prognostic factor in cardiac patients. However, platelet distribution width (PDW) was disclosed to be more specific marker of platelet reactivity. The aim of study was to evaluate whether baseline PDW value can predict the outcome in patients undergoing percutaneous coronary interventions (PCI) with drug-eluting stent implantation within coronary bifurcation lesions. MATERIALS AND METHODS: It was a two-centre observational study, which included patients who underwent PCI within bifurcation lesions between January 2014 and December 2014. Thrombocytopenia below 100 000/µL and STEMI were the exclusion criteria. Analysed data came entirely from in-hospital records and information obtained from the 12-month telephone follow-up. RESULTS: We included 269 patients. Mean PDW value was 13·4 ± 2·5 fL, whereas median was 13 (Q1 < 11·6 fL, Q2 11·6-13 fL, Q3 13-14·8 fL and Q4 > 14·8 fL). We found strong correlation between PDW and MPV (r = 0·96, P < 0·001), but no correlation was revealed between red blood cell distribution width (RDW) and PDW (r = 0·003, P = 0·95) as well as RDW and MPV (r = 0·0018, P = 0·98). Receiver operating characteristics (ROC) curve showed that PDW for cutoff 15·8% can predict MACE rate with sensitivity of 79% and specificity of 47% (area under curve - AUC 0·654; P = 0·01). A ROC curve for PDW categorized by 1-year TLR rate was described by optimal cutoff 16·3%, with sensitivity 69% and specificity 54% (AUC 0·697; P = 0·0015). CONCLUSIONS: PDW is an affordable and reliable predictor of 1-year MACE and TLR rate after PCI within coronary bifurcation lesions.


Assuntos
Doença da Artéria Coronariana/cirurgia , Volume Plaquetário Médio , Idoso , Aspirina/uso terapêutico , Plaquetas/fisiologia , Clopidogrel , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Revascularização Miocárdica/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Recidiva , Ticlopidina/análogos & derivados , Ticlopidina/uso terapêutico , Resultado do Tratamento
12.
Intervirology ; 59(3): 143-151, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-28081531

RESUMO

BACKGROUND: The meaning of viral nucleic acids in the myocardium in many cases is difficult for clinical interpretation, whereas the presence of viral nucleic acids in the serum is a marker of active infection. We determined the diagnostic value of viral nucleic acids in ventricular serum and peripheral serum samples in comparison with endomyocardial biopsy (EMB) specimens in patients with clinically suspected myocarditis. METHODS: The viral nucleic acid evaluation was performed in serum samples and EMB specimens by real-time PCR in 70 patients (age: 47 ± 16 years). The biopsy specimens were examined by histo- and immunohistochemistry to detect inflammatory response. RESULTS: The viral nucleic acids were detected in ventricular and peripheral serum, and EMB samples of 10 (14%), 14 (20%), and 32 (46%) patients, respectively. Notably, viral nucleic acids of the same virus as in the EMB sample were present more often in ventricular than in peripheral serum (60 vs. 7%, p = 0.01). A significant concurrence was observed between the positive and the negative results of viral nucleic acids present in EMB and ventricular serum (p = 0.0001). CONCLUSIONS: The detection of the same viral nucleic acid type in the myocardium and in ventricular serum being significantly more frequent than in the peripheral serum may suggest that the site of the blood collection is important for more precise and reliable confirmation of the active viral replication in the heart.


Assuntos
DNA Viral/sangue , Coração/virologia , Miocardite/sangue , Miocardite/virologia , RNA Viral/sangue , Viroses/diagnóstico , Viroses/virologia , Adulto , Biópsia , Coleta de Amostras Sanguíneas , Cardiomiopatia Dilatada/sangue , Cardiomiopatia Dilatada/virologia , DNA Viral/análise , Feminino , Humanos , Imuno-Histoquímica , Masculino , Pessoa de Meia-Idade , Miocardite/diagnóstico , Miocárdio/patologia , Miocárdio/ultraestrutura , RNA Viral/análise , Reação em Cadeia da Polimerase em Tempo Real , Replicação Viral , Adulto Jovem
13.
J Interv Cardiol ; 28(1): 51-60, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25689548

RESUMO

OBJECTIVES: The aim was to assess the effectiveness and safety profile of a new dedicated bifurcation stent - sirolimus-eluting BiOSS LIM® (Balton, Poland) in 12-month Registry. BACKGROUND: The optimal approach to coronary bifurcations treatment by percutaneous coronary intervention (PCI) has been still a subject of debate. Dedicated bifurcation stents are one of the proposed solutions. METHODS: This was the international, 3-center registry, which enrolled patients with non-ST-elevation acute coronary syndrome (NSTE-ACS) and stable angina. Provisional T-stenting was the obligatory strategy of the treatment. Angiographic control was planned at 12 months. The primary endpoint was cumulative rate of death, myocardial infarction (MI) and target lesion revascularization (TLR) at 12 months. RESULTS: A total of 60 patients with coronary bifurcations were enrolled (mean age 66.4 ± 11 years, 28.3% of female). There were 21.7% of patients with NSTE-ACS, 78.3% with hypertension, 38.3% with diabetes, 28.3% had previous MI, and 46.7% and 10% underwent prior revascularization, respectively, PCI and coronary artery bypass graft. The device success rate was 100%. Side branch was treated with an additional classical drug-eluting stent implantation in 23.3% of cases. At 12 months, the cumulative major adverse cardiovascular events rate was 11.7%. During follow-up (11 ± 1 months) there was 1 non-cardiac death (1.7%), 1 non-ST-elevated myocardial infarction (1.7%) due to restenosis and no case of stroke or in-stent thrombosis. Overall TLR was 8.3% (clinically driven TLR - 1.7%, angiographically driven - 6.6%). Mean late lumen loss was as follows: In main vessel - 0.35 ± 0.33 mm, in main branch - 0.34 ± 0.27 mm and in side branch - 0.18 ± 0.38 mm. CONCLUSION: Dedicated bifurcation stent BiOSS® LIM proved to be feasible device, with promising safety and long-term clinical effectiveness in the treatment of coronary bifurcation lesions, including distal left main stem stenosis.


Assuntos
Síndrome Coronariana Aguda/terapia , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo , Idoso , Reestenose Coronária/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Sistema de Registros
14.
BMC Cardiovasc Disord ; 15: 150, 2015 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-26573577

RESUMO

BACKGROUND: The aim of this study was to assess the safety and the efficacy of the novel sirolimus-eluting Prolim® stent with a biodegradable polymer in the all-comers population. METHODS: We prospectively enrolled all patients with stable coronary artery disease or acute coronary syndrome treated with Prolim® stent between January and December 2013 in two interventional cardiology centers in Poland. Angiographic control was planned at 12 months, in which 15 % of patients (randomly chosen) underwent optical coherence tomography imaging. The primary end-point was the cumulative rate of cardiac death, myocardial infarction, and target lesion revascularization at 12 months. RESULTS: There were 204 patients enrolled, in whom 238 Prolim® stents were deployed (1.17 stent per patient). The mean age was 68 ± 10 years and 32.8 % were females. The examined stent was implanted in 5.9 % in STEMI patients, in 21.6 % - in NSTE-ACS and in 72.5 % - in patients with stable coronary artery disease. The Prolim® stent was most frequently implanted in right coronary artery (38.2 %) followed by left anterior descending artery (34.0 %). The cumulative major adverse cardiovascular events rate at 12 months was 6.9 %, and the clinically-driven target lesion revascularization rate - 5.4 %. At 12 months in quantitative coronary angiography the late lumen loss was 0.21 ± 0.18 mm, and in optical coherence tomography the mean neointima burden was 24.6 ± 8.6 %. CONCLUSIONS: Sirolimus-eluting Prolim® stent with a biodegradable polymer is a feasible device with a very good safety profile and long-term clinical effectiveness. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov NCT02545985 .


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros , Sirolimo/administração & dosagem , Tomografia de Coerência Óptica , Síndrome Coronariana Aguda/diagnóstico , Síndrome Coronariana Aguda/mortalidade , Idoso , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Polônia , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
15.
J Interv Cardiol ; 27(3): 242-51, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24708143

RESUMO

OBJECTIVES: The aim of this study was to assess prospectively the effectiveness and safety profile of distal left main stem (LMS) stenosis treatment with dedicated bifurcation paclitaxel-eluting stent BiOSS Expert®. BACKGROUND: Angioplasty of distal LMS stenosis is always a high-risk procedure, and optimal treatment is uncertain. METHODS: This was a prospective international 2-center study, which enrolled patients with non-ST-elevation acute coronary syndrome (NSTE-ACS) or stable angina with distal left main stenosis. All patients were treated with the dedicated bifurcation stent BiOSS Expert®. Provisional T-stenting was the obligatory strategy. Angiographic control was performed after 12 months. The primary end-point was cumulative rate of death, myocardial infarction (MI), and target lesion revascularization (TLR) at 12 months. Angiographic end-points included late lumen loss, percent diameter stenosis, and binary restenosis rate. RESULTS: A total of 54 patients with distal LMS stenosis were enrolled. Seven patients (13%) were enrolled during NSTE-ACS, 77.8% were hypertensive, 27.8% were diabetic, 51.9% had previous MI, 53.7% underwent prior percutaneous coronary intervention, and 16.7% coronary artery bypass graft. The mean SYNTAX score was 21.52 ± 6.50. The device success rate was 100%. The mean BiOSS Expert stent parameters were as follows: 4.07 ± 0.26 mm × 3.36 ± 0.26 mm × 16.61 ± 1.72 mm and in side branch the other stent (classical drug-eluting stent) was implanted in 25.9% of cases. The overall TLR was 9.3%. There were no death, stent thrombosis, or acute MI. In the univariate regression analysis, the only factor associated with higher risk for TLR was the SYNTAX score value. CONCLUSIONS: The dedicated bifurcation stent BiOSS Expert® proved to be a feasible device, with promising safety and long-term clinical effectiveness in the treatment of distal LMS stenosis.


Assuntos
Angina Estável , Angioplastia Coronária com Balão , Estenose Coronária , Stents Farmacológicos , Paclitaxel/uso terapêutico , Idoso , Angina Estável/etiologia , Angina Estável/terapia , Angioplastia , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Antineoplásicos Fitogênicos/uso terapêutico , Angiografia Coronária/métodos , Estenose Coronária/complicações , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
16.
J Cardiovasc Dev Dis ; 11(6)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38921660

RESUMO

We characterized the performance, as well as the safety, of a second-generation thin-strut sirolimus-eluting stent with a biodegradable polymer, Alex Plus (Balton, Poland), implanted in patients with type 2 diabetes (DM) with a 4-year follow-up. We defined the primary endpoint as the 48-month rate of major cardiovascular adverse events (MACE), including cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR). The secondary endpoints were all-cause death, cardiac death, MI, and TLR rates at 12, 24, 36, and 48 months. We enrolled 232 patients in whom 282 stents were implanted, including 97 DM and 135 non-DM patients. The mean age of the DM patients was 69.5 ± 10.1 years and females accounted for 30% of the patients. DM patients had higher rates of arterial hypertension (97% vs. 88%, p = 0.016), dyslipidemia (86% vs. 70%, p = 0.005), prior MI (61% vs. 40%, p = 0.002), prior PCI (65% vs. 50%, p = 0.020), and prior CABG (14% vs. 5.9%, p = 0.029). We recorded statistically significant differences for MACE (HR 1.85, 95% CI 1.01-3.41, p = 0.046), cardiac death (HR 4.46, 95% CI 1.44-13.8, p = 0.010), and MI (HR 3.17, 95% CI 1.10-9.12, p = 0.033), but not for TLR, between DM and non-DM patients in terms of the analyzed endpoints at 4 years. Our study showed that Alex Plus was efficient and safe in a contemporary cohort of real-world DM patients undergoing percutaneous revascularization.

17.
Biomedicines ; 12(5)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38790900

RESUMO

This multicenter, randomized study aimed to compare the sirolimus-eluting BiOSS LIM C dedicated coronary bifurcation stent with second-generation -limus drug-eluting stents (rDESs) in the treatment of non-left main (non-LM) coronary bifurcation. The deployment of a single stent in the main vessel-main branch across a side branch was the default strategy in all patients. The primary endpoint was the rate of major cardiovascular events (cardiac death, myocardial infarction, and target lesion revascularization) at 48 months. We enrolled 230 patients, allocating 116 patients to the BiOSS LIM C group and 114 patients to the rDES group. Most procedures were elective (BiOSS vs. rDES: 48.3% vs. 59.6%, p = 0.09) and performed in bifurcations within the left anterior descending/diagonal branch (BiOSS vs. rDES: 51.7% vs. 61.4%, p = 0.15). At 48 months, there were no statistically significant differences between the BiOSS and rDES groups in terms of major adverse cardiovascular events (MACE), cardiac death, myocardial infarction (MI), or target lesion revascularization (TLR) as follows: MACEs-18.1% vs. 14.9%, HR 1.36, 95% CI 0.62-2.22, and p = 0.33; cardiac death-4.3% vs. 3.5%, HR 1.23, 95% CI 0.33-4.56, and p = 0.75; MI-2.6% vs. 3.5%, HR 0.73, 95% CI 0.17-3.23, and p = 0.68; and TLR-11.2% vs. 7.9%, HR 1.66, 95% CI 0.75-3.71, and p = 0.21. The implantation success rate of the BiOSS LIM C stent was very high, and the cumulative MACE rates were promising. The POLBOS 3 trial sets an important benchmark for treating non-LM coronary bifurcations (ClinicalTrials.gov NCT03548272).

18.
Kardiol Pol ; 2024 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-39177406

RESUMO

Percutaneous coronary interventions(PCI) are the cornerstone of treatment in patients with coronary artery disease, generating substantial costs for the healthcare system. Considerable improvement in PCI technique, stent technology and antiplatelet therapy led to a complication rate of <5%, a success rate of >95% and lack of routine cardiothoracic surgical support. Thereby, the concept of same-day discharge following PCI has been proposed due to comparable efficacy, safety, and socioeconomic benefits to inpatient PCI. Although single-vessel disease was the primary indication for outpatient (OP) PCI, more complex scenarios such as multivessel disease, left main disease and chronic total occlusions were shown to be feasible and safe in OP setting as well. Currently available data shows that OP PCI leads to cost optimization, increased PCI center capacity, decrease in nosocomial infections rate and increased patient satisfaction, along with good clinical outcomes. Although OP PCI seems promising in a subset of well-prepared and compliant patients without severe comorbidities, there are some challenges to overcome before its routine implementation. To prevent unnecessary hospitalizations and unsafe same-day discharges, interventional cardiology teams should be trained to perform reliable risk-benefit assessments. Standardized forms should be created to obtain informed consent and instruct OP PCI patients and their relatives about postprocedural management. Here, we summarize the available data on OP and inpatient PCI outcomes, discuss the opportunities and challenges of OP PCI and propose a periprocedural patient management checklist, with the goal of facilitating OP PCI implementation in interventional cardiology centers.

19.
Kardiol Pol ; 82(4): 398-406, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38638095

RESUMO

BACKGROUND: Side branch predilatation (SBPD) during coronary bifurcation interventions is a technique that is not recommended by the latest guidelines. However, the data about the clinical outcomes after SBPD are surprisingly few. AIMS: The current study aimed to explore the association between SBPD and mortality in long-term follow-up. METHODS: All patients with coronary bifurcation stenoses revascularized with percutaneous coronary intervention were included in a prospective registry. Patients with stable angina and a bifurcation lesion with ≥50% diameter stenosis were included in the current analysis. Patients were assigned to two groups - those with SBPD(+) and those without SBPD(-). Propensity score matching was performed to equalize the risk factors and severity of coronary artery disease between the groups. A Kaplan-Meier analysis with a log-rank test for between-group differences was also performed. RESULTS: From January 2013 to June 2021, 813 patients were included in the final study population. The mean age was 67 (10) years. After propensity score matching, 648 patients remained for analysis - 324 in each group. At a median follow-up of 57 months patients in the SBPD(+) group had a higher all-cause mortality (n = 107 (33%) vs. n = 98 [30.2%]; P = 0.045) and cardiovascular mortality (n = 82 [25.3%] vs. n = 70 [21.6%]; P = 0.03) when compared with SBPD(-) patients. SBPD was independently associated with all-cause and cardiovascular mortality. CONCLUSION: SBPD treatment of coronary bifurcation stenoses is associated with worse patient survival in the follow-up of up to 8 years. SBPD treatment gives better angiographic results, but this did not translate into better clinical outcomes.


Assuntos
Intervenção Coronária Percutânea , Humanos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Estenose Coronária/cirurgia , Estenose Coronária/terapia , Estenose Coronária/mortalidade , Estenose Coronária/diagnóstico por imagem , Sistema de Registros , Resultado do Tratamento , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Estudos Prospectivos , Seguimentos
20.
Circ Cardiovasc Interv ; 17(9): e014064, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39051094

RESUMO

BACKGROUND: Evidence suggests that drug-coated balloons may benefit in-stent restenosis (ISR) treatment. However, the efficacy of new-generation sirolimus-coated balloon (SCB) compared with the latest generation drug-eluting stents (DESs) has not been studied in this setting. METHODS: All patients in the EASTBORNE (The All-Comers Sirolimus-Coated Balloon European Registry) and DEB-DRAGON (DEB vs Thin-DES in DES-ISR: Long Term Outcomes) registries undergoing percutaneous coronary intervention for DES-ISR were included in the study. The primary study end point was target lesion revascularization at 24 months. Secondary end points were major adverse cardiovascular events, all-cause death, myocardial infarction, and target vessel revascularization at 24 months. Our goal was to evaluate the efficacy and safety of SCB versus thin-struts DES in ISR at long-term follow-up. RESULTS: A total of 1545 patients with 1679 ISR lesions were included in the pooled analysis, of whom 621 (40.2%) patients with 621 lesions were treated with thin-strut DES and 924 (59.8%) patients with 1045 lesions were treated with SCB. The unmatched cohort showed no differences in the incidence of target lesion revascularization (10.8% versus 11.8%; P=0.568); however, there was a trend toward lower rates of myocardial infarction (7.4% versus 5.0%; P=0.062) and major adverse cardiovascular events (20.8% versus 17.1%; P=0.072) in the SCB group. After propensity score matching (n=335 patients per group), there were no significant differences in the rates of target lesion revascularization (11.6% versus 11.8%; P=0.329), target vessel revascularization (14.0% versus 13.1%; P=0.822), myocardial infarction (7.2% versus 4.5%; P=0.186), all-cause death (5.7% versus 4.2%; P=0.476), and major adverse cardiovascular event (21.5% versus 17.6%; P=0.242) between DES and SCB treatment. CONCLUSIONS: In patients with ISR, angioplasty with SCB compared with thin-struts DES is associated with comparable rates of target lesion revascularization, target vessel revascularization, myocardial infarction, all-cause death, and major adverse cardiovascular events at 2 years.


Assuntos
Fármacos Cardiovasculares , Materiais Revestidos Biocompatíveis , Reestenose Coronária , Stents Farmacológicos , Sistema de Registros , Sirolimo , Humanos , Masculino , Feminino , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Reestenose Coronária/etiologia , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Reestenose Coronária/terapia , Fatores de Tempo , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Fatores de Risco , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Europa (Continente) , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/etiologia , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA