Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Mass Spectrom Rev ; 2023 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-37010157

RESUMO

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analysed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimisation of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.

2.
Mass Spectrom Rev ; 2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37056215

RESUMO

In food analysis, conventional one-dimensional liquid chromatography methods sometimes lack sufficient separation power due to the complexity and heterogeneity of the analyzed matrices. Therefore, the use of two-dimensional liquid chromatography (2D-LC) turns out to be a powerful tool to consider, especially when coupled to mass spectrometry (MS). This review presents the most remarkable 2D-LC-MS food applications reported in the last 10 years, including a critical discussion of the multiple approaches, modulation strategies as well as the importance of the optimization of the different analytical aspects that will condition the 2D-LC-MS performance. The presence of contaminants in food (food safety), the food quality, and authenticity or the relationship between the beneficial effects of food and human health are some of the fields in which most of the 2D-LC-MS applications are mainly focused. Both heart-cutting and comprehensive applications are described and discussed in this review, highlighting the potential of 2D-LC-MS for the analysis of such complex samples.

3.
Anal Chem ; 95(2): 854-861, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36538370

RESUMO

Dielectric barrier discharge ionization (DBDI) is a versatile tool for small-molecule mass spectrometry applications, helping cover from polar to low polar molecules. However, the plasma gas-phase interactions are highly complex and have been scarcely investigated. The ionization mechanisms of plasmas have long been assumed to be somewhat similar to atmospheric pressure chemical ionization (APCI). Here, we evaluated the ionization mechanisms of a two-ring DBDI ion source, using different discharge gases to analyze vaporized liquid samples. Polycyclic aromatic hydrocarbons (PAHs) were used as model analytes to assess the mechanisms' dominance: protonation, [M + H]+, or radical ion species formation, [M]·+. In the present work, two different ionization trends were observed for APCI and DBDI during the PAH analysis; the compounds with proton affinities (PA) over 856 kJ/mol were detected as [M + H]+ when APCI was used as ionization source. Meanwhile, independently of the PA, DBDI showed the prevalence of charge exchange reactions. The addition of dopants in the gas-phase region shifted the ionization mechanisms toward charge exchange reactions, facilitating the formation of [M]·+ ion species, showing anisole a significant boost of the PAH radical ion species signals, over nine times for Ar-Prop-DBDI analysis. The presence of high-energy metastable atoms (e.g., HeM) with high ionization potentials (IE = 19.80 eV) did not show boosted PAH abundances or extensive molecule fragmentation. Moreover, other species in the plasma jet region with closer and more appropriate IE, such as N2 B3Πg excited molecules, are likely responsible for PAH Penning ionization.


Assuntos
Hidrocarbonetos Policíclicos Aromáticos , Humanos , Hidrocarbonetos Policíclicos Aromáticos/análise , Espectrometria de Massas/métodos
4.
J Sep Sci ; 45(16): 3105-3114, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35801641

RESUMO

Dielectric barrier discharge ionization has gained attention in the last few years due to its versatility and the vast array of molecules that can be ionized. In this study, we report on the assessment of liquid chromatography coupled to dielectric barrier discharge ionization with mass spectrometry for neutral lipid analysis. A set of different neutral lipid subclasses (triacylglycerides, diacylglycerides, and sterols) were selected for the study. The main species detected from our ionization source were [M-H2 O+H]+ , [M+H]+ or [M-R-H2 O+H]+ , attributed to sterol dehydration, protonation or the fragmentation of an acyl chain accompanied by a water loss of the glycerolipids, respectively. In terms of sensitivity, the dielectric barrier discharge displayed overall improved abundances and comparable or better limits of quantitation than atmospheric pressure chemical ionization for both acylglycerols and sterols. As a case study, different archaeological samples with variable content in neutral lipids, particularly triacylglycerides, were studied. The identification was carried out by combining accurate mass and the tentative formula associated with the exact mass, retention time matching with standards, and additional structural information from in-source fragmentation. The high degree of unsaturation and the presence of sterols revealed the potential vegetal origin of the material stored in the analyzed samples.


Assuntos
Pressão Atmosférica , Esteróis , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida , Espectrometria de Massas , Espectrometria de Massas por Ionização por Electrospray
5.
Anal Chem ; 92(22): 15212-15220, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33135875

RESUMO

Ionization mechanisms of different lipid classes and other hydrophobic compounds have been evaluated in an ambient air laser-desorption flexible microtube plasma ionization (LD-FµTPi) setup, without sample manipulation. Lipids require a minimum laser fluency of 27 W/mm2 for efficient desorption and detection, providing the possibility for temperature-programmed laser desorption of different lipid classes. The flexible microtube plasma (FµTP) produces oxygen addition to double bonds, even to polyunsaturated molecules. The characteristic fragmentation pattern of phospholipids consisting of the neutral loss of the phosphocholine head group was verified. The formation of dimers due to hydrogen bonding and dispersion forces was observed as well. In this sense, soft ionization capabilities of the FµTP were proven in both ion modes. Ambient air mass spectrometry methods often suffer from decreased reproducibility, for instance, due to changing atmospheric conditions or sensitive positioning of the ion source. It was shown that neutrals become increasingly unstable above a distance of 7 ± 1 mm to the spectrometer's inlet, providing estimates for the free volume in LD-FµTPi MS. In this sense, no guided transport is required. The ion plume ejected from the plasma can be altered by applying a bias voltage to the copper substrate. Ions can be detected at -950 V, 300 V (negative ion mode) and -400 V, 900 V (positive ion mode), respectively. The ions are guided through an internal electric field gradient of the FµTP that arises from charged capillary walls, ideal for ion detection. In conclusion, this makes the method fast, robust, and flexible.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Lipídeos/análise , Lipídeos/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Limite de Detecção , Oxigênio/química , Gases em Plasma/química
6.
Anal Chem ; 92(6): 4663-4671, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32106668

RESUMO

This study introduced sandwich-structured copper-glass substrates for standardization of laser desorption and plasma ionization. For standardized quantitative analysis, cavities were constructed which allow better reproducibility in droplet deposition and for laser application. Applying the diode laser, molten substrate material is incorporated into the glass, being trapped inside. Therefore, this method can be separated from laser ablation, achieving high ion signals without ablating material from the surface. Flexible microtube plasma (FµTP) was selected as the ionization source, this being the first time that laser desorption and FµTP ionization are coupled. This laser-plasma interface was applied to the detection of cholesterol, which showed a significantly improved limit of detection of 0.46 ng and linear dynamic range of 3 orders of magnitude in positive ion mode compared to other (ambient air mass spectrometry) methods. The main reason was the change of phase on the copper surface. The dehydrated molecule [M-H2O+H]+ was the base peak of the spectrum and no further dissociation or fragmentation was observed. Blood plasma was spiked with cholesterol. In a 1:100 chloroform dilution, the presence of the plasma was neglectable and led to the same detection limits and linear dynamic range as in the cholesterol standard. No sample preparation or internal standards were needed for calibration. The physical effects of the surface modification were investigated, including the calculation of the laser beam waist to simplify the comparison and reproducibility of results.


Assuntos
Colesterol/sangue , Cobre/química , Lasers , Colesterol/normas , Cobre/normas , Vidro/química , Vidro/normas , Humanos , Lasers/normas , Estrutura Molecular , Tamanho da Partícula , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/normas , Propriedades de Superfície
7.
Mar Drugs ; 18(6)2020 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-32545497

RESUMO

In the present study, the chemical composition of the microalga Euglena cantabrica was investigated. The extraction of bioactive compounds was done using pressurized liquid extraction (PLE) at different temperatures (40-180 °C) and using green solvents (ethanol-water mixtures). A statistical design of experiments was used to optimize the maximum antioxidant capacity of the extracts by response surface methodology. The antioxidant capacity was determined through the inhibition of 2,2'-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid (ABTS) and 1,1-diphenyl-2-picrylhydrazyl (DPPH) radicals, while the chemical analyses of the extracts were carried out using different chromatographic techniques. Chlorophylls and carotenoids were analyzed by high-performance liquid chromatography coupled to a diode array detector and mass spectrometry (HPLC-DAD-MS/MS) and carbohydrates by gas chromatography with flame ionization detection (GC-FID) and high-pressure size-exclusion chromatography coupled to an evaporative light-scattering detector (HPSEC-ELSD). The results showed different possibilities for the extraction conditions, depending on the desired bioactivity or chemical composition. Briefly, (i) mixtures of ethanol-water containing around 40% ethanol at 180 °C gave the best antioxidant capacity, (ii) mixtures containing around 50% ethanol at 110 °C gave the best yield of ß-glucan paramylon, and (iii) the use of pure ethanol at a low temperature (40 °C) is the best choice for the recovery of carotenoids such as diatoxanthin. Summing up, E. cantabrica seems to be a good candidate to be used in biorefinery to obtain different bioactive compounds.


Assuntos
Euglena/química , Extratos Vegetais/química , Animais , Solventes , Temperatura
8.
Anal Bioanal Chem ; 411(19): 4785-4796, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30707264

RESUMO

In this work, the multiclass detection of explosives and related compounds has been studied by liquid chromatography-high-resolution mass spectrometry by means of a time-of-flight mass spectrometer (TOFMS) operated in the negative ion mode, using dielectric barrier discharge ionization (DBDI). Reversed-phase high-performance liquid chromatography (HPLC) separation was performed using water-methanol mobile phase without any modifier, although the effect of ammonium acetate was studied. DBD plasma was generated by applying a square wave voltage of 2.5 kV to a 100-mL min-1 He flow. The DBDI probe was adjusted to fit the commercial API source housing so that the HPLC eluent was nebulized and vaporized in the same manner as for atmospheric-pressure chemical ionization (APCI). The ionization process was affected by the temperature of the two nitrogen streams used to vaporize the solvent and the analytes, particularly for RDX and HMX, which are thermolabile compounds. The best approach in terms of sensitivity for all the studied compounds was the use of a gradient of temperatures in the ionization source, starting at 225/200 °C (vaporizer/drying gas temp) for nitramines and ending at 350/325 °C for nitroaromatic compounds. High-resolution full-scan spectra of individual selected compounds were recorded by LC-DBDI-TOFMS, and the results were compared to LC-APCI-TOFMS. A better sensitivity (slope of calibration curve) was obtained by DBDI for more than 70% of the studied compounds in both wastewater and soil extracts. Graphical abstract ᅟ.

9.
Electrophoresis ; 39(13): 1673-1682, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29314152

RESUMO

Pressurized liquid extraction (PLE) has been used for the first time in this work to extract phenolic compounds from Goji berries according to a multilevel factorial design using response surface methodology. The global yield (% w/dw, weight/dry-weight), total phenolic content (TPC), total flavonoid (TF) and antioxidant activity (determined via ABTS assay, expressed as TEAC value) were used as response variables to study the effects of temperature (50-180°C) and green solvent composition (mixtures of ethanol/water). Phenolic compounds characterization was performed by high performance liquid chromatography-diode array detector-tandem mass spectrometry (HPLC-DAD-MS/MS). The optimum PLE conditions predicted by the model were as follows: 180°C and 86% ethanol in water with a good desirability value of 0.815. The predicted conditions were confirmed experimentally and once the experimental design was validated for commercial fruit samples, the PLE extraction of phenolic compounds from three different varieties of fruit samples (Selvatico mongolo, Bigol, and Polonia) was performed. Nine phenolic compounds were tentatively identified in these extracts, including phenolic acids and their derivatives, and flavonols. The optimized PLE conditions were compared to a conventional solid-liquid extraction, demonstrating that PLE is a useful alternative to extract phenolic compounds from Goji berry.


Assuntos
Antioxidantes/química , Lycium/química , Fenóis/química , Flavonoides/química , Frutas/química , Hidroxibenzoatos/química , Extração em Fase Sólida
10.
Electrophoresis ; 2018 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-29683520

RESUMO

In the present work, the valorization of Nannochloropsis gaditana biomass is proposed within the concept of biorefinery. To this aim, high-pressure homogenization (HPH) was used to break down the strong cell wall and supercritical fluid extraction (SFE) with pure CO2 was applied as a first step to extract valuable compounds (such as non-polar lipids and pigments). Extraction of the remaining residue for the recovery of bioactive compounds was studied by means of an experimental design based on response surface methodology (RSM) employing pressurized liquid extraction (PLE) with green solvents such as water and ethanol. Optimum extract was achieved with pure ethanol at 170°C for 20 min, providing an important antioxidant capacity (0.72 ± 0.03 mmol trolox eq g-1 extract). Complete chemical characterization of the optimum extract was carried out by using different chromatographic methods such as reverse-phase high-performance liquid chromatography with diode array detection (RP-HPLC-DAD), normal-phase HPLC with evaporative light scattering detection (NP-HPLC-ELSD) and gas chromatography coupled to mass spectrometry detection (GC-MS); carotenoids (e.g. violaxanthin), chlorophylls and polar lipids were the main compounds observed while palmitoleic, palmitic, myristic acids and the polyunsaturated eicosapentanoic (EPA) acid were the predominant fatty acids in all PLE extracts.

11.
Electrophoresis ; 37(13): 1938-46, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27122439

RESUMO

This work aims at studying the optimization of microwave-assisted extraction (MAE) and pressurized liquid extraction (PLE) by multi-response surface methodology (RSM) to test their efficiency towards the extraction of phenolic compounds from Moringa oleifera (M. oleifera) leaves. The extraction yield, total phenolic content (TPC), total flavonoid content (TF), DPPH scavenging method and trolox equivalent antioxidant capacity (TEAC) assay were considered as response variables while effects of extraction time, percentage of ethanol, and temperature were studied. Extraction time of 20 min, 42% ethanol and 158°C were the MAE optimum conditions for achieving extraction yield of 26 ± 2%, EC50 15 ± 2 µg/mL, 16 ± 1 Eq Trolox/100 g dry leaf, 5.2 ± 0.5 mg Eq quercetin/g dry leaf, and 86 ± 4 mg GAE/g dry leaf. Regarding PLE, the optimum conditions that allowed extraction yield of 56 ± 2%, EC50 21 ± 3 µg/mL, 12 ± 2 mmol Eq Trolox/100 g dry leaf, 6.5 ± 0.2 mg Eq quercetin/g dry leaf, and 59 ± 6 mg GAE/g dry leaf were 128°C, 35% of ethanol, and 20 min. PLE enabled the extraction of phenolic compounds with a higher number of hydroxyl-type substituents such as kaempferol diglycoside and its acetyl derivatives and those that are sensitive to high temperatures (glucosinolates or amino acids) while MAE allowed better recoveries of kaempferol, quercetin, and their glucosides derivatives.


Assuntos
Micro-Ondas , Moringa oleifera/química , Fenóis/isolamento & purificação , Folhas de Planta/química , Antioxidantes/farmacologia , Pressão , Propriedades de Superfície
12.
Anal Bioanal Chem ; 408(18): 4857-69, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27178548

RESUMO

The aim of the study was to evaluate the performance of different chromatographic approaches for the liquid chromatography/mass spectrometry (LC-MS(/MS)) determination of 24 highly polar pesticides. The studied compounds, which are in most cases unsuitable for conventional LC-MS(/MS) multiresidue methods were tested with nine different chromatographic conditions, including two different hydrophilic interaction liquid chromatography (HILIC) columns, two zwitterionic-type mixed-mode columns, three normal-phase columns operated in HILIC-mode (bare silica and two silica-based chemically bonded columns (cyano and amino)), and two standard reversed-phase C18 columns. Different sets of chromatographic parameters in positive (for 17 analytes) and negative ionization modes (for nine analytes) were examined. In order to compare the different approaches, a semi-quantitative classification was proposed, calculated as the percentage of an empirical performance value, which consisted of three main features: (i) capacity factor (k) to characterize analyte separation from the void, (ii) relative response factor, and (iii) peak shape based on analytes' peak width. While no single method was able to provide appropriate detection of all the 24 studied species in a single run, the best suited approach for the compounds ionized in positive mode was based on a UHPLC HILIC column with 1.8 µm particle size, providing appropriate results for 22 out of the 24 species tested. In contrast, the detection of glyphosate and aminomethylphosphonic acid could only be achieved with a zwitterionic-type mixed-mode column, which proved to be suitable only for the pesticides detected in negative ion mode. Finally, the selected approach (UHPLC HILIC) was found to be useful for the determination of multiple pesticides in oranges using HILIC-ESI-MS/MS, with limits of quantitation in the low microgram per kilogram in most cases. Graphical Abstract HILIC improves separation of multiclass polar pesticides.


Assuntos
Cromatografia Líquida/métodos , Análise de Alimentos/métodos , Contaminação de Alimentos/análise , Espectrometria de Massas/métodos , Praguicidas/análise , Praguicidas/química , Interações Hidrofóbicas e Hidrofílicas , Transição de Fase , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água/química
13.
Chemosphere ; 357: 142075, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38648985

RESUMO

Pesticides are considered one of the main sources of contamination of surface waters, especially in rural areas highly influenced by traditional agricultural practices. The objective of this work was to evaluate the impact caused by pesticides and their transformation products (TPs) related to olive groves in surface waters with strong agricultural pressure. 11 streams were monitored during four sampling campaigns over 2 years. A solid-phase extraction, followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS) analysis was used in the quantitative target approach, with more than 70 validated compounds. Target method was combined with a suspect screening strategy involving more than 500 pesticides and TPs, using ultra-high-performance liquid chromatography coupled to high-resolution mass spectrometry (UHPLC-HRMS) to identify additional pesticides and TPs out of the scope of analysis. A total of 43 different compounds were detected with the target method. The herbicide MCPA was present in all samples and at the highest concentration (1260 ng L-1), followed by the fungicide carbendazim (1110 ng L-1), and the herbicide chlorotoluron (706 ng L-1). The suspect screening strategy revealed the presence of 7 compounds out of the target analysis (1 pesticide and 6 TPs). 6 analytes were confirmed with the analytical standards. Semi-quantification results revealed that TPs exhibited higher concentrations than their corresponding parent compounds, indicating higher persistency. Some small streams showed a comparable number of pesticides and concentrations to the most polluted large river. The determined pesticide and TPs concentrations represented an estimated environmental hazard in almost all sampling sites under study. This work underscores the importance of including pesticide TPs and small streams impacted by extensive agricultural activities in water quality monitoring programs.


Assuntos
Agricultura , Monitoramento Ambiental , Olea , Praguicidas , Rios , Espectrometria de Massas em Tandem , Poluentes Químicos da Água , Rios/química , Poluentes Químicos da Água/análise , Praguicidas/análise , Medição de Risco , Olea/química , Extração em Fase Sólida , Carbamatos/análise , Cromatografia Líquida de Alta Pressão , Herbicidas/análise , Benzimidazóis/análise , Compostos de Fenilureia
14.
Talanta ; 274: 126011, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38574537

RESUMO

In this article, we have studied the potential of flexible microtube plasma (FµTP) as ionization source for the liquid chromatography high-resolution mass spectrometry detection of non-easily ionizable pesticides (viz. nonpolar and non-ionizable by acid/basic moieties). Phthalimide-related compounds such as dicofol, dinocap, o-phenylphenol, captan, captafol, folpet and their metabolites were studied. Dielectric barrier discharge ionization (DBDI) was examined using two electrode configurations, including the miniaturized one based on a single high-voltage (HV) electrode and a virtual ground electrode configuration (FµTP), and also the two-ring electrode DBDI configuration. Different ionization pathways were observed to ionize these challenging, non-easily ionizable nonpolar compounds, involving nucleophilic substitutions and proton abstraction, with subtle differences in the spectra obtained compared with APCI. An average sensitivity increase of 5-fold was attained compared with the standard APCI source. In addition, more tolerance with matrix effects was observed in both DBDI sources. The importance of the data reported is not just limited to the sensitivity enhancement compared to APCI, but, more notably, to the ability to effectively ionize nonpolar, late-eluting (in reverse-phase chromatography) non-ionizable compounds. Besides o-phenylphenol ([M - H]-), all the parent species were efficiently ionized through different mechanisms involving bond cleavages through the effect of plasma reagent species or its combination with thermal degradation and subsequent ionization. This tool can be used to figure out overlooked nonpolar compounds in different environmental samples of societal interest through non-target screening (NTS) strategies.


Assuntos
Espectrometria de Massas , Praguicidas , Praguicidas/análise , Praguicidas/química , Praguicidas/sangue , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Ftalimidas/química , Ftalimidas/análise , Contaminação de Alimentos/análise , Miniaturização , Captana/análise , Captana/sangue , Captana/química , Análise de Alimentos/métodos
15.
Anal Chem ; 85(6): 3174-82, 2013 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-23419061

RESUMO

In this work, the combined use of desorption by a continuous wave near-infrared diode laser and ionization by a dielectric barrier discharge-based probe (laser desorption dielectric barrier discharge ionization mass spectrometry (LD-DBDI-MS)) is presented as an ambient ionization method for the mass spectrometric detection of nonvolatile chemicals on surfaces. A separation of desorption and ionization processes could be verified. The use of the diode laser is motivated by its low cost, ease of use, and small size. To achieve an efficient desorption, the glass substrates are coated at the back side with a black point (target point, where the sample is deposited) in order to absorb the energy offered by the diode laser radiation. Subsequent ionization is accomplished by a helium plasmajet generated in the dielectric barrier discharge source. Examples on the application of this approach are shown in both positive and negative ionization modes. A wide variety of multiclass species with low vapor pressure were tested including pesticides, pharmaceuticals and explosives (reserpine, roxithromycin, propazine, prochloraz, spinosad, ampicillin, dicloxacillin, enrofloxacin, tetracycline, oxytetracycline, erythromycin, spinosad, cyclo-1,3,5,7-tetramethylene tetranitrate (HMX), and cyclo-1,3,5-trimethylene trinitramine (RDX)). A comparative evaluation revealed that the use of the laser is advantageous, compared to just heating the substrate surface.


Assuntos
Substâncias Explosivas/análise , Lasers Semicondutores , Praguicidas/análise , Preparações Farmacêuticas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos
16.
Rapid Commun Mass Spectrom ; 27(3): 419-29, 2013 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23280973

RESUMO

RATIONALE: The present study reports on the evaluation of dielectric barrier discharge microplasma ionization (DBDI) for liquid chromatography/high resolution mass spectrometry (LC/HRMS) analyses of pesticide residues in fruit and vegetables. Ionization, fragmentation, analytical performance and matrix effects displayed by LC/DBDI-MS were critically evaluated and compared with both atmospheric pressure chemical ionization (APCI) and electrospray (ESI), using a set of over 40 representative multiclass pesticides. METHODS: Sample preparation was accomplished using standard QuEChERS procedure and the identification and quantitation of the pesticides tested accomplished by means of LC/MS with a hybrid linear quadrupole ion trap (LIT)-Fourier transform ion cyclotron resonance (FTICR) mass spectrometer operated in full-scan positive ion mode using DBDI, APCI and ESI sources. RESULTS: The developed LC/DBDI-MS method allowed the screening of 43 pesticides in three different vegetable matrices: apple, orange and tomato. Minor matrix effects (i.e. signal suppression or enhancement ≤20%) were observed in most of the studied compounds: 95%, 70% and 81% of the studied compounds showed minor matrix effects in extracts of apple, orange and tomato, respectively. The results of the analysis of spiked orange extracts showed that the sensitivity obtained with LC/DBDI-MS is appropriate for multi-residue analysis of pesticide residues in fruit and vegetable samples. The limits of quantitation (LOQs) obtained for most of the studied pesticides were in compliance with the European Regulation 396/2005 (and subsequent updates) on food commodities (default maximum residue level of 10 µg kg(-1)). CONCLUSIONS: Comparative studies with commercial sources demonstrate the suitability of DBDI as an ionization technique for residue analysis, because of the combination of the following two advantages: (1) the use of DBDI provides minimized matrix effects compared with APCI, and (2) improved the detection - in terms of sensitivity - of selected compounds that are not easily ionized by ESI, such as parathion.


Assuntos
Espectrometria de Massas/métodos , Resíduos de Praguicidas/química , Cromatografia Líquida de Alta Pressão , Citrus sinensis/química , Frutas/química , Solanum lycopersicum/química , Malus/química , Resíduos de Praguicidas/análise , Resíduos de Praguicidas/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Verduras/química
17.
Anal Bioanal Chem ; 405(14): 4729-35, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23532393

RESUMO

The present study contributes to the evaluation of dielectric barrier discharge-based ambient ionization for mass spectrometric analysis (DBDI-MS) by providing a further step towards an understanding of underlying ionization processes. This examination highlights the effect of physical discharge modes on the ionization efficiency of the DBDI source. A distinction is made between the homogeneous and filamentary discharge mode due to different plasma gases in barrier configurations. Therefore, we first report on discharge modes of DBDI by demonstrating a universally applicable method to classify the predominant modes. Then, the ionization efficiency of these two modes is evaluated by a laser desorption-DBDI-MS with different molecular analytes. Here, the laser desorption is used to deliver neutral analytes which will be ionized by the plasma jet applied as dielectric barrier discharge ionization. With a clear increase of signal intensities in the homogeneous mode in contrast to the filamentary one, the present study indicates a pronounced dependence of the ionization efficiency on the discharge mode allowing further insight into the mechanisms of the ionization process.

18.
Analyst ; 137(22): 5403-10, 2012 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-23013838

RESUMO

A Dielectric Barrier Discharge Ionization (DBDI) LC/MS interface is based on the use of a low-temperature helium plasma, which features the possibility of simultaneous ionization of species with a wide variety of physicochemical properties. In this work, the performance of LC/DBDI-MS for trace analysis of highly relevant species in food and environment has been examined. Over 75 relevant species including multiclass priority organic contaminants and residues such as pesticides, polycyclic aromatic hydrocarbons, organochlorine species, pharmaceuticals, personal care products, and drugs of abuse were tested. LC/DBDI-MS performance for this application was assessed and compared with standard LC/MS sources (electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI)). The used benchtop Orbitrap mass spectrometer features a 10 Hz polarity switching mode, so that both positive and negative ion mode acquisitions are possible with acquisition cycles matching the requirements of fast liquid chromatography. Both polar and nonpolar species (including those typically analyzed by GC/electron ionization-MS) can be tested in a single run using polarity switching mode. The methodology was found to be effective in detecting a wide array of organic compounds at concentration levels in the low ng L(-1) to µg kg(-1) range in wastewater and food matrices, respectively. The linearity was evaluated in an olive oil extract, obtaining good correlation coefficients in the studied range. Additionally, minor matrix effects (≤15% of signal suppression or enhancement) were observed for most of the studied analytes in this complex fatty matrix. The results obtained were compared with data from both ESI and APCI sources, obtaining a merged coverage between ESI and APCI in terms of analyte ionization and higher overall sensitivity for the proposed ion source based on the DBD principle. The use of this approach further extends the coverage of current LC/MS methods towards an even larger variety of chemical species including both polar and nonpolar (non-ESI amenable) species and may find several applications in fields such as food and environment testing or metabolomics where GC/MS and LC/MS are combined to cover as many different species as possible.


Assuntos
Cromatografia Líquida de Alta Pressão , Contaminação de Alimentos/análise , Compostos Orgânicos/análise , Espectrometria de Massas por Ionização por Electrospray , Pressão Atmosférica , Cromatografia Gasosa-Espectrometria de Massas , Metabolômica , Azeite de Oliva , Óleos de Plantas/química , Águas Residuárias/análise
19.
Anal Bioanal Chem ; 404(5): 1495-503, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22773228

RESUMO

In this work, a method for the determination of trace nitrotyrosine (NO(2)Tyr) and tyrosine (Tyr) in Arabidopsis thaliana cell cultures is proposed. Due to the complexity of the resulting extracts after protein precipitation and enzymatic digestion and the strong electrospray signal suppression displayed in the detection of both Tyr and NO(2)Tyr from raw A. thaliana cell culture extracts, a straightforward sample cleanup step was proposed. It was based on the use of mixed-mode solid-phase extraction (SPE) using MCX-type cartridges (Strata™-X-C), prior to identification and quantitation using fast liquid chromatography-electrospray time-of-flight mass spectrometry. Unambiguous confirmation of both amino acids was accomplished with accurate mass measurements (with errors lower than 2 ppm) of each protonated molecule along with a characteristic fragment ion for each species. Recovery studies were accomplished to evaluate the performance of the SPE sample preparation step obtaining average recoveries in the range 92-101%. Limit of quantitation obtained for NO(2)Tyr in A. thaliana extracts was 3 nmol L(-1). Finally, the proposed method was applied to evaluate stress conditions of the plant upon different concentrations of peroxynitrite, a protein-nitrating compound, which induces the nitration of Tyr at the nanomolar range. Detection and confirmation of the compounds demonstrated the usefulness of the proposed approach.


Assuntos
Arabidopsis/química , Extração em Fase Sólida/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Tirosina/análogos & derivados , Cromatografia Líquida/métodos , Limite de Detecção , Tirosina/análise
20.
Food Chem ; 365: 130486, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34237571

RESUMO

After more than ten years since pesticide residues were detected in citrus-flavored soft drinks, this study reveals that the situation has not changed. A new sensitive multiresidue UHPLC-MS/MS method has been validated for 88 pesticides, which was used to analyze 200 samples manufactured in 67 countries, 80% corresponding to fruit-based soft drinks. The results show that 98% of the samples collected worldwide contained at least one pesticide, and 85% of them contained more than 4 pesticides. 40 out of 88 target compounds were quantified among the screened samples. Europe was the world region with the highest total amount of pesticides, probably due to the higher content of juice concentrate in samples, which may be the main source of the pesticide residues. Nevertheless, residues were also found in samples with no juice, so water quality also plays an important role as the main ingredient of citrus-flavored soft drinks.


Assuntos
Citrus , Resíduos de Praguicidas , Bebidas Gaseificadas/análise , Contaminação de Alimentos/análise , Resíduos de Praguicidas/análise , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA