Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Pediatr ; 183(6): 2625-2636, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38492032

RESUMO

Neonates face heightened susceptibility to drug toxicity, often exposed to off-label medications with dosages extrapolated from adult or pediatric studies. Premature infants in Neonatal Intensive Care Units (NICUs) are particularly at risk due to underdeveloped pharmacokinetics and exposure to multiple drugs. The study aimed to survey commonly used medications with a higher risk of ototoxicity and nephrotoxicity in Spanish and Italian neonatal units. A prospective cross-sectional study was conducted in Italian and Spanish neonatal units using a web-based survey with 43 questions. A modified Delphi method involved experts refining the survey through online consensus. Ethical approval was obtained, and responses were collected from January to July 2023. The survey covered various aspects, including drug-related ototoxic and nephrotoxic management, hearing screening, and therapeutic drug monitoring. Responses from 131 participants (35.9% from Spain and 64.1% from Italy) revealed awareness of drug toxicity risks. Varied practices were observed in hearing screening protocols, and a high prevalence of ototoxic and nephrotoxic drug use, including aminoglycosides (100%), vancomycin (70.2%), loop diuretics (63.4%), and ibuprofen (62.6%). Discrepancies existed in guideline availability and adherence, with differences between Italy and Spain in therapeutic drug monitoring practices. CONCLUSIONS: The study underscores the need for clinical guidelines and uniform practices in managing ototoxic and nephrotoxic drugs in neonatal units. Awareness is high, but inconsistencies in practices indicate a necessity for standardization, including the implementation of therapeutic drug monitoring and the involvement of clinical pharmacologists. Addressing these issues is crucial for optimizing neonatal care in Southern Europe. WHAT IS KNOWN: • Neonates in intensive care face a high risk of nephrotoxicity and ototoxicity from drugs like aminoglycosides, vancomycin, loop diuretics, and ibuprofen. • Therapeutic drug monitoring is key for managing these risks, optimizing dosing for efficacy and minimizing side effects. WHAT IS NEW: • NICUs in Spain and Italy show high drug toxicity awareness but differ in ototoxic/nephrotoxic drug management. • Urgent need for standard guidelines and practices to address nephrotoxic risks from aminoglycosides, vancomycin, loop diuretics, and ibuprofen.


Assuntos
Aminoglicosídeos , Unidades de Terapia Intensiva Neonatal , Ototoxicidade , Vancomicina , Humanos , Itália , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Estudos Transversais , Estudos Prospectivos , Espanha , Aminoglicosídeos/efeitos adversos , Ototoxicidade/etiologia , Vancomicina/efeitos adversos , Monitoramento de Medicamentos/métodos , Monitoramento de Medicamentos/estatística & dados numéricos , Ibuprofeno/efeitos adversos , Inibidores de Simportadores de Cloreto de Sódio e Potássio/efeitos adversos , Inquéritos e Questionários , Feminino , Nefropatias/induzido quimicamente , Nefropatias/epidemiologia , Recém-Nascido Prematuro , Masculino
2.
Eur J Pediatr ; 182(9): 4173-4183, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37436521

RESUMO

The aim of the present study, endorsed by the Union of European Neonatal and Perinatal Societies (UENPS) and the Italian Society of Neonatology (SIN), was to analyze the current delivery room (DR) stabilization practices in a large sample of European birth centers that care for preterm infants with gestational age (GA) < 33 weeks. Cross-sectional electronic survey was used in this study. A questionnaire focusing on the current DR practices for infants < 33 weeks' GA, divided in 6 neonatal resuscitation domains, was individually sent to the directors of European neonatal facilities, made available as a web-based link. A comparison was made between hospitals grouped into 5 geographical areas (Eastern Europe (EE), Italy (ITA), Mediterranean countries (MC), Turkey (TUR), and Western Europe (WE)) and between high- and low-volume units across Europe. Two hundred and sixty-two centers from 33 European countries responded to the survey. At the time of the survey, approximately 20,000 very low birth weight (VLBW, < 1500 g) infants were admitted to the participating hospitals, with a median (IQR) of 48 (27-89) infants per center per year. Significant differences between the 5 geographical areas concerned: the volume of neonatal care, ranging from 86 (53-206) admitted VLBW infants per center per year in TUR to 35 (IQR 25-53) in MC; the umbilical cord (UC) management, being the delayed cord clamping performed in < 50% of centers in EE, ITA, and MC, and the cord milking the preferred strategy in TUR; the spotty use of some body temperature control strategies, including thermal mattress mainly employed in WE, and heated humidified gases for ventilation seldom available in MC; and some of the ventilation practices, mainly in regard to the initial FiO2 for < 28 weeks' GA infants, pressures selected for ventilation, and the preferred interface to start ventilation. Specifically, 62.5% of TUR centers indicated the short binasal prongs as the preferred interface, as opposed to the face mask which is widely adopted as first choice in > 80% of the rest of the responding units; the DR surfactant administration, which ranges from 44.4% of the birth centers in MC to 87.5% in WE; and, finally, the ethical issues around the minimal GA limit to provide full resuscitation, ranging from 22 to 25 weeks across Europe. A comparison between high- and low-volume units showed significant differences in the domains of UC management and ventilation practices.    Conclusion: Current DR practice and ethical choices show similarities and divergences across Europe. Some areas of assistance, like UC management and DR ventilation strategies, would benefit of standardization. Clinicians and stakeholders should consider this information when allocating resources and planning European perinatal programs. What is Known: • Delivery room (DR) support of preterm infants has a direct influence on both immediate survival and long-term morbidity. • Resuscitation practices for preterm infants often deviate from the internationally defined algorithms. What is New: • Current DR practice and ethical choices show similarities and divergences across Europe. Some areas of assistance, like UC management and DR ventilation strategies, would benefit of standardization. • Clinicians and stakeholders should consider this information when allocating resources and planning European perinatal programs.

3.
Acta Paediatr ; 107(10): 1684-1696, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29751368

RESUMO

AIM: We reviewed using a high-flow nasal cannula (HFNC) as first-line support for preterm neonates with, or at risk of, respiratory distress. METHODS: This rapid systematic review covered biomedical databases up to June 2017. We included randomised controlled trials (RCTs) published in English. The reference lists of the studies and relevant reviews we included were also screened. We performed the study selection, data extraction, study quality assessment, meta-analysis and quality of evidence assessment following the Grading of Recommendations Assessment, Development and Evaluation system. RESULTS: Pooled results from six RCTs covering 1227 neonates showed moderate-quality evidence that HFNC was associated with a higher rate of failure than nasal continuous positive airway pressure (NCPAP) in preterm neonates of at least 28 weeks of gestation, with a risk ratio of 1.57. Low-quality evidence showed no significant differences between HFNC and NCPAP in the need for intubation and bronchopulmonary dysplasia rate. HFNC yielded a lower rate of nasal injury (risk ratio 0.50). When HFNC failed, intubation was avoided in some neonates by switching them to NCPAP. CONCLUSION: HFNC had higher failure rates than NCPAP when used as first-line support. Subsequently switching to NCPAP sometimes avoided intubation. Data on the most immature neonates were lacking.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Ventilação não Invasiva/instrumentação , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Cânula , Humanos , Recém-Nascido , Recém-Nascido Prematuro
5.
Am J Perinatol ; 32(10): 939-43, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25811328

RESUMO

OBJECTIVES: Transient tachypnea of the neonate (TTN) is the commonest neonatal respiratory disorder. Given TTN physiopathology, continuous positive airway pressure (CPAP) could be indicated for its treatment, but no data are available. Our aim is to clarify if CPAP might reduce the TTN burden of care. DESIGN: Retrospective multicenter cohort study enrolling 42 full-term TTN babies treated with CPAP and 40 with oxygen supplementation. RESULTS: CPAP-treated infants show shorter intensive care unit stay (CPAP, 2.5 ± 2 vs. Oxygen, 4.4 ± 2.6 days; adjß, -2.1 [95% confidence interval (CI): -3.1; -1]); p < 0.001) and lower maximal oxygen fraction (adjß, -4.7 [95% CI: -7.7; -1.7]; p = 0.003). Air leak incidence was similar between the groups (adjOR, 0.36 [95% CI: 0.1; 1.1); p = 0.08). Patients' comfort as per EDIN score was also unchanged. Given the shorter length of intensive care, the use of CPAP for treating TTN would spare on average around 7,000 Euros/infant. CONCLUSION: CPAP seems a useful therapeutics for TTN, as it may reduce the burden of care without increasing air leaks or patients' discomfort.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Oxigenoterapia/métodos , Taquipneia Transitória do Recém-Nascido/terapia , Estudos de Coortes , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
6.
Acta Paediatr ; 103(6): 605-11, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24606020

RESUMO

AIM: To evaluate any geographical variations in practice and adherence to international guidelines for early delivery room management of extremely low birthweight (ELBW) infants in the North, Centre and South of Italy. METHODS: A questionnaire was sent to all 107 directors of Italian level III centres between April and August 2012. RESULTS: There was a 92% (n = 98) response rate. A polyethylene bag/wrap was used by 54 centres (55.1%), with the highest rate in Northern Italy (77.5%) and the lowest rate in Southern (37.7%) areas. In Northern regions, one centre (2.5%) said it used oxygen concentrations >40% to initiate positive pressure ventilation in ELBW infants. These proportions were higher in the Central (14.3%) and Southern (16.2%) areas. A T-piece device for positive pressure ventilation was more frequently available in the Northern (95%) units than in those in the Central (66.7%) and Southern (69.4%) regions. A median of 13% (IQR: 5%-30%) of ELBW infants received chest compressions at birth in Italy: 5%, 18% and 22% in Northern, Central and Southern units, respectively. CONCLUSION: In Italy, delivery room management of ELBW infants showed marked geographical variations. Implementation of national training programmes could increase adherence to the guidelines and reduce such discordance.


Assuntos
Salas de Parto/estatística & dados numéricos , Gerenciamento Clínico , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Respiração Artificial/estatística & dados numéricos , Ressuscitação/estatística & dados numéricos , Salas de Parto/organização & administração , Salas de Parto/normas , Geografia , Fidelidade a Diretrizes/estatística & dados numéricos , Pesquisas sobre Atenção à Saúde , Humanos , Lactente , Mortalidade Infantil/tendências , Recém-Nascido , Itália , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Respiração com Pressão Positiva/estatística & dados numéricos , Guias de Prática Clínica como Assunto/normas , Respiração Artificial/métodos , Respiração Artificial/normas , Ressuscitação/métodos , Ressuscitação/normas , Inquéritos e Questionários , Análise de Sobrevida
7.
Neonatology ; : 1-11, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834044

RESUMO

INTRODUCTION: Laryngeal mask airway (LMA) use in neonatal resuscitation is limited despite existing evidence and recommendations. This survey investigated the knowledge and experience of healthcare providers on the use of the LMA and explored barriers and solutions for implementation. METHODS: This online, cross-sectional survey on LMA in neonatal resuscitation involved healthcare professionals of the Union of European Neonatal and Perinatal Societies (UENPS). RESULTS: A total of 858 healthcare professionals from 42 countries participated in the survey. Only 6% took part in an LMA-specific course. Some delivery rooms were not equipped with LMA (26.1%). LMA was mainly considered after the failure of a face mask (FM) or endotracheal tube (ET), while the first choice was limited to neonates with upper airway malformations. LMA and FM were considered easier to position but less effective than ET, while LMA was considered less invasive than ET but more invasive than FM. Participants felt less competent and experienced with LMA than FM and ET. The lack of confidence in LMA was perceived as the main barrier to its implementation in neonatal resuscitation. More training, supervision, and device availability in delivery wards were suggested as possible actions to overcome those barriers. CONCLUSION: Our survey confirms previous findings on limited knowledge, experience, and confidence with LMA, which is usually considered an option after the failure of FM/ET. Our findings highlight the need for increasing the availability of LMA in delivery wards. Moreover, increasing LMA training and having an LMA expert supervisor during clinical practice may improve the implementation of LMA use in neonatal clinical practice.

8.
Children (Basel) ; 11(2)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38397269

RESUMO

(1) Background: Our survey aimed to gather information on respiratory care in Neonatal Intensive Care Units (NICUs) in the European and Mediterranean region. (2) Methods: Cross-sectional electronic survey. An 89-item questionnaire focusing on the current modes, devices, and strategies employed in neonatal units in the domain of respiratory care was sent to directors/heads of 528 NICUs. The adherence to the "European consensus guidelines on the management of respiratory distress syndrome" was assessed for comparison. (3) Results: The response rate was 75% (397/528 units). In most Delivery Rooms (DRs), full resuscitation is given from 22 to 23 weeks gestational age. A T-piece device with facial masks or short binasal prongs are commonly used for respiratory stabilization. Initial FiO2 is set as per guidelines. Most units use heated humidified gases to prevent heat loss. SpO2 and ECG monitoring are largely performed. Surfactant in the DR is preferentially given through Intubation-Surfactant-Extubation (INSURE) or Less-Invasive-Surfactant-Administration (LISA) techniques. DR caffeine is widespread. In the NICUs, most of the non-invasive modes used are nasal CPAP and nasal intermittent positive-pressure ventilation. Volume-targeted, synchronized intermittent positive-pressure ventilation is the preferred invasive mode to treat acute respiratory distress. Pulmonary recruitment maneuvers are common approaches. During NICU stay, surfactant administration is primarily guided by FiO2 and SpO2/FiO2 ratio, and it is mostly performed through LISA or INSURE. Steroids are used to facilitate extubation and prevent bronchopulmonary dysplasia. (4) Conclusions: Overall, clinical practices are in line with the 2022 European Guidelines, but there are some divergences. These data will allow stakeholders to make comparisons and to identify opportunities for improvement.

9.
Int J Infect Dis ; 140: 17-24, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38157929

RESUMO

OBJECTIVES: To describe how SARS-CoV-2 infection at the time of delivery affected maternal and neonatal outcomes across four major waves of the COVID-19 pandemic in Italy. METHODS: This is a large, prospective, nationwide cohort study collecting maternal and neonatal data in case of maternal peripartum SARS-CoV-2 infection between February 2020 and March 2022. Data were stratified across the four observed pandemic waves. RESULTS: Among 5201 COVID-19-positive mothers, the risk of being symptomatic at delivery was significantly higher in the first and third waves (20.8-20.8%) than in the second and fourth (13.2-12.2%). Among their 5284 neonates, the risk of prematurity (gestational age <37 weeks) was significantly higher in the first and third waves (15.6-12.5%). The risk of intrauterine transmission was always very low, while the risk of postnatal transmission during rooming-in was higher and peaked at 4.5% during the fourth wave. A total of 80% of positive neonates were asymptomatic. CONCLUSION: The risk of adverse maternal and neonatal outcomes was significantly higher during the first and third waves, dominated by unsequenced variants and the Delta variant, respectively. Postnatal transmission accounted for most neonatal infections and was more frequent during the Omicron period. However, the paucity of symptoms in infected neonates should lead us not to separate the dyad.


Assuntos
COVID-19 , Neonatologia , Complicações Infecciosas na Gravidez , Recém-Nascido , Feminino , Gravidez , Humanos , Lactente , SARS-CoV-2 , COVID-19/epidemiologia , Pandemias , Estudos Prospectivos , Estudos de Coortes , Transmissão Vertical de Doenças Infecciosas , Itália/epidemiologia , Mães , Complicações Infecciosas na Gravidez/epidemiologia
10.
JAMA Netw Open ; 7(9): e2435347, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39320892

RESUMO

Importance: A multicenter randomized clinical trial (RCT) showed a lung recruitment maneuver using high-frequency oscillatory ventilation just before surfactant administration (ie, intubate-recruit-surfactant-extubate [IN-REC-SUR-E]) improved the efficacy of treatment compared with the standard intubate-surfactant-extubate (IN-SUR-E) technique without increasing the risk of adverse neonatal outcomes. Objective: To examine follow-up outcomes at corrected postnatal age (cPNA) 2 years of preterm infants previously enrolled in an RCT and treated with IN-REC-SUR-E or IN-SUR-E in 35 tertiary neonatal intensive care units. Design, Setting, and Participants: This was a follow-up study of infants recruited into the primary RCT from 2015 to 2018 at 35 tertiary neonatal intensive care units (NICUs) in Italy. Follow-up examinations included neurodevelopmental, growth, and respiratory outcomes of these children at cPNA 2 years. Participants included spontaneously breathing extremely preterm neonates (24 0/7 to 27 6/7 weeks' gestation) reaching failure criteria for continuous positive airway pressure within the first 24 hours of life. Data were analyzed from April 2023 to January 2024. Intervention: Infants were randomly assigned (1:1) to IN-REC-SUR-E or IN-SUR-E and then followed up. Main Outcomes and Measures: The primary outcome was the occurrence of death after discharge or major disability at cPNA 2 years. Secondary outcomes were neurodevelopmental outcomes (major disability, cerebral palsy, cognitive impairment, visual deficit, or auditory deficit), anthropometric measurements (weight, length, and head circumference), and recurrent respiratory infections and hospitalizations because of respiratory causes at 2y cPNA. Results: A total of 137 extremely preterm infants (median [IQR] gestational age, 26.5 [25.3-27.5] weeks and 75 [54.7%] female), initially enrolled in the original RCT, were followed up at cPNA 2 years, including 64 infants in the IN-SUR-E group and 73 infants in the IN-REC-SUR-E group. There were no significant differences in the occurrence of death after discharge or major disability at cPNA 2 years (IN-SUR-E: 13 children [20.3%] vs IN-REC-SUR-E: 10 children [13.7%]; P = .36). There were no significant differences in incidence of disability, cerebral palsy, or cognitive impairment in the IN-REC-SUR-E group compared with the IN-SUR-E group. There were no significant differences in anthropometric measurements (weight, length, and head circumference) between groups. There were no significant differences in the incidence of recurrent respiratory infections or in hospitalizations because of respiratory causes between groups. Conclusions and Relevance: In this RCT of lung recruitment before surfactant vs standard care there were no significant differences between the 2 groups in death, neurodevelopmental outcomes, anthropometric measurements, or recurrent respiratory infections at the 2-year follow-up. These findings can aid clinicians in decision-making for the best strategy to administer surfactant, considering long-term outcomes.


Assuntos
Lactente Extremamente Prematuro , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Humanos , Surfactantes Pulmonares/administração & dosagem , Surfactantes Pulmonares/uso terapêutico , Masculino , Feminino , Recém-Nascido , Seguimentos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Ventilação de Alta Frequência/métodos , Pré-Escolar , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Resultado do Tratamento , Itália , Lactente
11.
Am J Clin Pathol ; 160(6): 640-647, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37555848

RESUMO

OBJECTIVES: To compare umbilical cord and neonatal blood for chemistry tests upon admission to the neonatal intensive care unit (NICU). METHODS: We designed a prospective, bicentric cohort study enrolling newborns (n = 71) with a planned admission to the NICU. Paired samples of umbilical cord and infant's blood were collected, analyzed, and compared. An intraclass correlation coefficient (ICC) was calculated for a repeatability analysis, and a Bland-Altman analysis was performed to assess the agreement between the 2 methods of sampling. The multivariable coefficient of determination (R2) was reported to quantify the degree of correlation between the methods of measurement. RESULTS: The degree of agreement between the 2 sampling methods for chemistry tests was fair to good for high-sensitivity C-reactive protein (ICC = 0.79 [95% CI, 0.67-0.87]), phosphorus (ICC = 0.83 [95% CI, 0.73-0.90]), and albumin (ICC = 0.76 [95% CI, 0.60-0.86]), while it was good to excellent for γ-glutamyl transpeptidase (ICC = 0.95 [95% CI, 0.88-0.98]) and procalcitonin (ICC = 0.90 [95% CI, 0.76-0.96]). CONCLUSIONS: Umbilical cord blood is a reliable replacement source for multiple chemistry tests at birth. This sampling method has the potential to minimize the risk of transfusion-requiring anemia in newborns and its associated complications. Further studies are warranted to assess the efficacy of this strategy in improving neonatal outcomes.


Assuntos
Transfusão de Sangue , Cordão Umbilical , Lactente , Recém-Nascido , Humanos , Estudos de Coortes , Estudos Prospectivos , Sangue Fetal
12.
Ital J Pediatr ; 48(1): 21, 2022 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-35115016

RESUMO

OBJECTIVE: To evaluate the role and the advantages of nasopharyngeal swabs in the detection of Influenza A and B viruses and Respiratory syncytial virus through a rapid test based upon a nucleic acid amplification reaction in order to avoid improper antibiotics use. DESIGN: Case-control retrospective study. SETTING: Emergency Room of "Sandro Pertini" General Hospital, Rome, Italy. PARTICIPANTS: Children (< 14 years old) who consecutively arrived in the Emergency Department (ED) for respiratory tract infections, without obvious signs of bacterial respiratory tract infections and other comorbidities, in the maximal seasonal incidence period of November-to-March of every year between 2016 and 2020. METHODS: Medical records of children included in the study were retrospectively examined. Children were subdivided according to the following intervals: 2016-2017 and 2017-2018 (Group 1), 2018-2019 and 2019-2020 (Group 2). Children in Group 2 undertook a nasopharyngeal swab, while those in Group 1 did not undergo any specific diagnostic test. PRIMARY OUTCOME: Avoidance of improper antibiotics administration. RESULTS: A total of 386 children were included in the study: 174 in Group 1, 212 in Group 2. The Odd Ratio (OR) of prescribing an antibiotic in the groups of children not being swabbed compared to those of children undertaking a swab was 9.21 (CI95% 5.6-15.2, p < 0.001). The overall percentage of hospitalizations, both in the short observation unit or in the pediatric unit, did not differ between the two groups. CONCLUSIONS: Nasopharyngeal swabs for the detection of Influenza A and B viruses and Respiratory syncytial virus proved to be a useful means to a correct and timely diagnosis and allowed for a significant reduction in the prescription of antibiotic therapy. TRIAL REGISTRATION: Retrospectively registered.


Assuntos
Influenza Humana , Infecções por Vírus Respiratório Sincicial , Vírus Sincicial Respiratório Humano , Infecções Respiratórias , Adolescente , Criança , Humanos , Lactente , Influenza Humana/diagnóstico , Influenza Humana/epidemiologia , Infecções Respiratórias/diagnóstico , Infecções Respiratórias/tratamento farmacológico , Infecções Respiratórias/epidemiologia , Estudos Retrospectivos
13.
Ital J Pediatr ; 48(1): 165, 2022 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-36068631

RESUMO

Intraosseous (IO) access offers a fast and reliable route for administration of fluids and drugs when intravenous (IV) accesses like umbilical, peripheral, or peripherally inserted central lines fail in critically ill neonates. Several medications can be successfully administered via the IO route, however only limited information is available regarding IO administration of antiviral agents.We present the case of a 2-week-old neonate, admitted to the Neonatal Intensive Care Unit (NICU) due to suspected meningitis, who received acyclovir through IO infusion after the venous access was lost and a new one could not be established. No complications were reported within 12 months of follow up.This report highlights the feasibility of IO acyclovir infusion when IV accesses fail in a critically ill neonate.


Assuntos
Estado Terminal , Infusões Intraósseas , Aciclovir , Humanos , Recém-Nascido , Tíbia
14.
Ital J Pediatr ; 48(1): 81, 2022 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-35655278

RESUMO

BACKGROUND: Providing appropriate care at birth remains a crucial strategy for reducing neonatal mortality and morbidity. We aimed to evaluate the consistency of practice and the adherence to the international guidelines on neonatal resuscitation in level-I and level-II Italian birth hospitals. METHODS: This was a cross-sectional electronic survey. A 91-item questionnaire focusing on current delivery room practices in neonatal resuscitation was sent to the directors of 418 Italian neonatal facilities. RESULTS: The response rate was 61.7% (258/418), comprising 95.6% (110/115) from level-II and 49.0% (148/303) from level-I centres. In 2018, approximately 300,000 births occurred at the participating hospitals, with a median of 1664 births/centre in level-II and 737 births/centre in level-I hospitals. Participating level-II hospitals provided nasal-CPAP and/or high-flow nasal cannulae (100%), mechanical ventilation (99.1%), HFOV (71.0%), inhaled nitric oxide (80.0%), therapeutic hypothermia (76.4%), and extracorporeal membrane oxygenation ECMO (8.2%). Nasal-CPAP and/or high-flow nasal cannulae and mechanical ventilation were available in 77.7 and 21.6% of the level-I centres, respectively. Multidisciplinary antenatal counselling was routinely offered to parents at 90.0% (90) of level-II hospitals, and 57.4% (85) of level-I hospitals (p < 0.001). Laryngeal masks were available in more than 90% of participating hospitals while an end-tidal CO2 detector was available in only 20%. Significant differences between level-II and level-I centres were found in the composition of resuscitation teams for high-risk deliveries, team briefings before resuscitation, providers qualified with full resuscitation skills, self-confidence, and use of sodium bicarbonate. CONCLUSIONS: This survey provides insight into neonatal resuscitation practices in a large sample of Italian hospitals. Overall, adherence to international guidelines on neonatal resuscitation was high, but differences in practice between the participating centres and the guidelines exist. Clinicians and stakeholders should consider this information when allocating resources and planning perinatal programs in Italy.


Assuntos
Neonatologia , Ressuscitação , Estudos Transversais , Feminino , Humanos , Recém-Nascido , Parto , Gravidez , Inquéritos e Questionários
15.
Pediatr Pulmonol ; 57(9): 2199-2206, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35637553

RESUMO

INTRODUCTION: Lung ultrasound (LU) is a noninvasive, bedside imaging technique that is attracting growing interest in the evaluation of neonatal respiratory diseases. We conducted a nationwide survey of LU usage in Italian neonatal intensive care units (NICUs). METHODS: A structured questionnaire was developed and sent online to 114 Italian NICUs from June to September 2021. RESULTS: The response rate was 79%. In the past 4 years (range: 2-6), LU has been adopted in 82% of Italian NICUs. It is the first-choice diagnostic test in 23% of the centers surveyed. The main LU diagnostic applications reported were: pneumothorax (95%), respiratory distress syndrome (89%), transient tachypnea of the newborn (89%), plural effusion (88%), atelectasis (66%), pneumonia (64%), bronchopulmonary dysplasia (43%), congenital pulmonary airway malformation (41%), and congenital diaphragmatic hernia (34%). Thirty percent of participating centers calculated LU score routinely, but only seven units used it to predict the need for surfactant replacement. Sixty-six percent of respondents learned the LU technique via a self-training process, while 34% of them visited an expert in the field for one-to-one tuition. CONCLUSIONS: LU has a widespread use in Italian NICUs. However, the use of LU is extremely heterogeneous among centers. There is an urgent need to ensure standardization of clinical practice guidelines and to design and implement a formalized and accredited training program.


Assuntos
Malformação Adenomatoide Cística Congênita do Pulmão , Unidades de Terapia Intensiva Neonatal , Humanos , Recém-Nascido , Itália/epidemiologia , Pulmão/diagnóstico por imagem , Ultrassonografia
16.
J Matern Fetal Neonatal Med ; 35(25): 8514-8520, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34645354

RESUMO

INTRODUCTION: During the first year of the COVID-19 pandemic, international recommendations and guidelines regarding breastfeeding-supportive hospital practices changed frequently. For example, some recommended separation of mothers and infants; others, feeding pumped milk instead of milk fed directly from the breast. Many recommendations were inconsistent or in direct conflict with each other. Guidance from UENPS (the Union of European Neonatal and Perinatal Societies) published in April 2020 recommended rooming in and direct breastfeeding where feasible, under strict measures of infection control, for women who were COVID-19 positive or under investigation for COVID-19. KEY FINDINGS: Our study assessed data from respondents from 124 hospitals in 22 nations, with over 1000 births per year, who completed a survey on practices during the COVID-19 epidemic, as they related to the World Health Organization (WHO) Ten Steps to Successful Breastfeeding, considered to be the gold standard for breastfeeding support. The survey was conducted in the fall of 2020/winter of 2021. Overall 88% of responding hospitals had managed COVID positive mothers, and 7% had treated over 50 birthing women with confirmed COVID-19. The biggest change to hospital policy related to visitation policies, with 38% of hospitals disallowing all visitors for birthing women, and 19% shortening the postpartum stay. Eight hospitals (6%) recommended formula feeding instead of breastfeeding for women who tested positive for COVID-19 or were under investigation, whereas 73% continued to recommend direct, exclusive breastfeeding, but with some form of protection such as a mask or hand sanitizer for the mother or cleaning the breast before the feed. While 6% of hospitals discontinued rooming in, 31% strengthened their rooming in policy (keeping mothers and their babies together in the same room) to protect infants against possible exposure to the virus elsewhere in the hospital . Overall, 72% of hospitals used their country's national guidelines when making policy, 31% used WHO guidelines and 22% UENPS/SIN guidelines. Many European hospitals relied on more than one accredited source. DISCUSSION: Our most concerning finding was that 6% of hospitals recommended formula feeding for COVID positive mothers, a measure that was later shown to be potentially harmful, as protection against the virus is transmitted through human milk. It is encouraging to note that a third of hospitals strengthened rooming in measures. Especially given the emergence of the highly transmissible Delta variant, the situation around postnatal care in maternity hospitals requires ongoing monitoring and may require proactive investment to regain pre-COVID era practices.


Assuntos
COVID-19 , Complicações Infecciosas na Gravidez , Lactente , Recém-Nascido , Feminino , Gravidez , Humanos , Aleitamento Materno , COVID-19/epidemiologia , COVID-19/prevenção & controle , Pandemias/prevenção & controle , SARS-CoV-2 , Maternidades
17.
Neonatology ; 119(2): 184-192, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051924

RESUMO

BACKGROUND: We aimed to evaluate the policies and practices about neonatal resuscitation in a large sample of European hospitals. METHODS: This was a cross-sectional electronic survey. A 91-item questionnaire focusing on the current delivery room practices in neonatal resuscitation domains was individually sent to the directors of 730 European neonatal facilities or (in 5 countries) made available as a Web-based link. A comparison was made between hospitals with ≤2,000 and those with >2,000 births/year and between hospitals in 5 European areas (Eastern Europe, Italy, Mediterranean countries, Turkey, and Western Europe). RESULTS: The response rate was 57% and included participants from 33 European countries. In 2018, approximately 1.27 million births occurred at the participating hospitals, with a median of 1,900 births/center (interquartile range: 1,400-3,000). Routine antenatal counseling (p < 0.05), the presence of a resuscitation team at all deliveries (p < 0.01), umbilical cord management (p < 0.01), practices for thermal management (p < 0.05), and heart rate monitoring (p < 0.01) were significantly different between hospitals with ≤2,000 births/year and those with >2,000 births/year. Ethical and educational aspects were similar between hospitals with low and high birth volumes. Significant variance in practice, ethical decision-making, and training programs were found between hospitals in 5 different European areas. CONCLUSIONS: Several recommendations about available equipment and clinical practices recommended by the international guidelines are already implemented by centers in Europe, but a large variance still persists. Clinicians and stakeholders should consider this information when allocating resources and planning European perinatal programs.


Assuntos
Ressuscitação , Estudos Transversais , Europa (Continente) , Feminino , Humanos , Recém-Nascido , Itália , Gravidez , Inquéritos e Questionários
18.
Clin Perinatol ; 48(4): 745-759, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34774207

RESUMO

Avoiding MV is a critical goal in neonatal respiratory care. Different modes of noninvasive respiratory support beyond nasal CPAP, such as nasal intermittent positive pressure ventilation (NIPPV) and synchronized NIPPV (SNIPPV), may further reduce intubation rates. SNIPPV offers consistent benefits over nonsynchronized techniques such as a more efficient positive pressure transmission to the lung, an effective increase in transpulmonary pressure during ventilation, and a better stabilization of the chest wall during inspiration. This review discusses mechanisms of action, benefits and limitations of synchronized noninvasive ventilation, describes the different modes of synchronization, and analyzes properties and clinical results.


Assuntos
Ventilação não Invasiva , Síndrome do Desconforto Respiratório do Recém-Nascido , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
19.
Pediatr Pulmonol ; 56(2): 400-408, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33169945

RESUMO

BACKGROUND: Although short binasal prongs (SBP) are the most common interface for noninvasive ventilation, the "double-inspiratory loop cannulas" (DILC) have recently been introduced into many neonatal intensive care units. DILC show advantages over SBP, including reduced nasal trauma and increased comfort. However, their higher intrinsic resistance may compromise ventilation. Our aim was to test a new, low resistance DILC interface. METHODS: A test lung was programmed to simulate preterm neonates (500-2000 g BW) with moderate-to-severe respiratory distress syndrome. The artificial nose was designed to keep prongs-to-nares leaks to around 30%. Giulia® ventilator (GINEVRI srl) was used to provide nasal continuous positive airway pressure (NCPAP) and flow synchronized nasal intermittent positive pressure ventilation (NIPPV). NCPAP was set at 4-10 cmH2 O and synchronized-NIPPV (SNIPPV) at peak inspiratory pressure, 15-20-25 cmH2 O; inspiratory time, 0.3-0.5 s; and positive end-expiratory pressure, 5-8 cmH2 O. Four sizes of Sync-flow Cannula® (GINEVRI srl) were tested. The Sync-flow Cannula® was compared with Neotech RAM® cannula and Ginevri SBP®. The outcome measures were the flow/pressure relationship through the four Sync-flow Cannula® sizes, the difference in resistance, the drop in ventilator-alveoli pressure measured by the test lung and the system response time during flow-SNIPPV. RESULTS: The smaller DILC sizes had the lowest flow-pressure ratio. The resistance of the RAM® cannula was significantly higher compared to the other interfaces (p < .001). With 30% leaks, there was a 4-38% ventilator-alveoli drop in pressure, depending on interface size. The system response time was excellent (~65-70 ms). CONCLUSIONS: With about 30% leaks, the Sync-flow Cannula® interfaces result in good pressure transmission and give optimal performance for flow-SNIPPV. Clinical studies are needed to confirm the clinical relevance of these data.


Assuntos
Cânula , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Ventilação com Pressão Positiva Intermitente/instrumentação , Humanos , Recém-Nascido , Pulmão , Modelos Biológicos , Nariz
20.
Arch Dis Child Fetal Neonatal Ed ; 106(6): 572-577, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33597230

RESUMO

BACKGROUND: The thermal servo-controlled systems are routinely used in neonatal intensive care units (NICUs) to accurately manage patient temperature, but their role during the immediate postnatal phase has not been previously assessed. OBJECTIVE: To compare two modalities of thermal management (with and without the use of a servo-controlled system) immediately after birth. STUDY DESIGN AND SETTING: Multicentre, unblinded, randomised trial conducted 15 Italian tertiary hospitals. PARTICIPANTS: Infants with estimated birth weight <1500 g and/or gestational age <30+6 weeks. INTERVENTION: Thermal management with or without a thermal servo-controlled system during stabilisation in the delivery room. PRIMARY OUTCOME: Proportion of normothermia at NICU admission (axillary temperature 36.5°C-37.5°C). RESULTS: At NICU admission, normothermia was achieved in 89/225 neonates (39.6%) with the thermal servo-controlled system and 95/225 neonates (42.2%) without the thermal servo-controlled system (risk ratio 0.94, 95% CI 0.75 to 1.17). Thermal servo-controlled system was associated with increased mild hypothermia (36°C-36.4°C) (risk ratio 1.48, 95% CI 1.09 to 2.01). CONCLUSIONS: In very low birthweight infants, thermal management with the servo-controlled system conferred no advantage in maintaining normothermia at NICU admission, while it was associated with increased mild hypothermia. Thermal management of preterm infants immediately after birth remains a challenge. TRIAL REGISTRATION NUMBER: NCT03844204.


Assuntos
Temperatura Corporal/fisiologia , Hipotermia , Incubadoras para Lactentes , Cuidado do Lactente , Doenças do Prematuro , Termometria/métodos , Feminino , Idade Gestacional , Humanos , Hipotermia/diagnóstico , Hipotermia/etiologia , Hipotermia/fisiopatologia , Hipotermia/terapia , Cuidado do Lactente/instrumentação , Cuidado do Lactente/métodos , Recém-Nascido , Recém-Nascido Prematuro , Doenças do Prematuro/diagnóstico , Doenças do Prematuro/fisiopatologia , Doenças do Prematuro/terapia , Recém-Nascido de muito Baixo Peso/fisiologia , Unidades de Terapia Intensiva Neonatal , Masculino , Avaliação de Resultados em Cuidados de Saúde , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA