1.
Catheter Cardiovasc Interv ; 98(4): 723-732, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34164905

RESUMO

OBJECTIVES: To investigate the long-term vasomotor response and inflammatory changes in Absorb bioresorbable vascular scaffold (BVS) and metallic drug-eluting stent (DES) implanted artery. BACKGROUND: Clinical evidence has demonstrated that compared to DES, BVS is associated with higher rates of target lesion failure. However, it is not known whether the higher event rates observed with BVS are related to endothelial dysfunction or inflammation associated with polymer degradation. METHODS: Ten Absorb BVS and six Xience V DES were randomly implanted in the main coronaries of six nonatherosclerotic swine. At 4-years, vasomotor response was evaluated in vivo by quantitative coronary angiography response to intracoronary infusion of Ach and ex vivo by the biomechanical response to prostaglandin F2-α (PGF2-α), substance P and bradykinin and gene expression analysis. RESULTS: Absorb BVS implanted arteries showed significantly restored vasoconstrictive responses after Ach compared to in-stent Xience V. The contractility of Absorb BVS treated segments induced by PGF2-α was significantly greater compared to Xience V treated segments and endothelial-dependent vasorelaxation was greater with Absorb BVS compared to Xience V. Gene expression analyses indicated the pro-inflammatory lymphotoxin-beta receptor (LTßR) signaling pathway was significantly upregulated in arteries treated with a metallic stent compared to Absorb BVS treated arterial segments. CONCLUSIONS: At 4 years, arteries treated with Absorb BVS compared with Xience V, demonstrate significantly greater restoration of vasomotor responses. Genetic analysis suggests mechanobiologic reparation of Absorb BVS treated arteries at 4 years as opposed to Xience V treated vessels.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Animais , Everolimo , Expressão Gênica , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Stents , Suínos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 97(7): 1331-1340, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32659048

RESUMO

BACKGROUND: Provisional side branch (SB) stenting is correlated with target vessel myocardial infarction (TVMI) in patients with coronary bifurcation lesions. However, the mechanisms underlying this association remain unknown. OBJECTIVES: To determine the correlation between SB lesion length with vulnerable plaques and TVMI using optical coherence tomography (OCT). BACKGROUND: The correlation between SB lesion length with vulnerable plaques and TVMI is unknown. METHODS: A total of 405 patients with 405 bifurcation lesions who underwent preprocedure OCT imaging of both the main vessel (MV) and the SB were enrolled. Patients were divided into long SB lesion (SB lesion length ≥10 mm) and short SB lesion (SB lesion length <10 mm) groups according to quantitative coronary analysis; they were also stratified by the presence of vulnerable plaques identified by OCT. The primary endpoint was the occurrence of TVMI after provisional stenting at 1-year follow-up. RESULTS: In total, 178 (43.9%) patients had long SB lesions. Vulnerable plaques were predominantly localized in the MV and were more frequently in the long SB lesion group (42.7%) than in the short SB lesion group (24.2%, p < .001). At 1-year follow-up after provisional stenting, there were 31 (7.7%) TVMIs, with 21 (11.8%) in the long SB lesion group and 10 (4.4%) in the short SB lesion group (p = .009). Multivariate regression analysis showed that long SB lesion length (p = .011), absence of vulnerable plaques in the polygon of confluence (p = .001), and true coronary bifurcation lesions (p = .004) were the three independent factors of TVMI. CONCLUSIONS: The presence of long SB lesion with MV vulnerable plaques predicts the increased risk of TVMI after provisional stenting in patients with true coronary bifurcation lesions. Further studies are warranted to identify the best stenting techniques for coronary bifurcation lesions with long SB lesions.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Infarto do Miocárdio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Fatores de Risco , Stents , Tomografia de Coerência Óptica , Resultado do Tratamento
3.
Cardiovasc Drugs Ther ; 35(2): 331-341, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33085027

RESUMO

PURPOSE: This study was to analyze the incidence of definite stent thrombosis (ST) after the implantation of drug-eluting stents (DESs) and cutoff value of overlapping length for predicting definite ST. An overlapping stent is associated with a high rate of clinical events after DES implantation compared with a non-overlapping stent. However, the rates of definite ST and clinical outcomes from a large patient population remain underreported. METHODS: A total of 15,561 patients with 24,183 lesions who underwent DES implantation from January 2005 to February 2017 were retrospectively included in 5 tertiary hospitals in China. The main endpoint was the incidence of definite ST after procedures. RESULTS: With a median of 1932 (IQR = 1194-2929) days, clinical follow-up was available in 7484 patients in the overlap group and in 8077 patients in the non-overlap group. The rates of definite ST were 3.1% in the overlap group and 1.2% in the non-overlap group (HR: 2.67 (95% CI: 2.11-3.38), p < 0.001). Of the 24,183 treated lesions, the incidences of definite ST were 2.4% in the overlap group and 0.9% in the non-overlap group (HR: 2.96 (95% CI: 2.38-3.69), p < 0.001). Stent overlap was associated with a higher rate of target lesion revascularization (TLR) (9.4%) compared with stent non-overlap (6.4%, p < 0.001). The length of overlapping stent ≥ 2.93 mm strongly correlated with definite ST. CONCLUSION: The present study shows that overlapping DES increases definite ST and revascularization in patients during long-term follow-up. In addition, the longer overlapping zone was associated with worse clinical outcomes.


Assuntos
Trombose Coronária/epidemiologia , Stents Farmacológicos/estatística & dados numéricos , Revascularização Miocárdica/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Fatores Etários , Idoso , Fármacos Cardiovasculares/uso terapêutico , China/epidemiologia , Comorbidade , Terapia Antiplaquetária Dupla/métodos , Feminino , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Incidência , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
4.
Catheter Cardiovasc Interv ; 92(4): 651-652, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30341829

RESUMO

What the article teaches The article highlights the competency of high volume operators across institutions that despite moving to lower volume centers retain their good clinical outcomes. How it will impact practice Although current U.S. based guidelines suggest a volume of at least 50 PCIs annually for operators to retain clinical competency this estimate may be a poor index to guarantee optimal clinical outcomes. What new research/study would help answer the question New studies using a comprehensive definition to define an experienced operator from the Asia-Pacific-a geographic area that has pioneered in complex coronary interventions-need to elute on the threshold of adequate clinical competency stratified according to clinical complexity.


Assuntos
Hospitais com Alto Volume de Atendimentos , Intervenção Coronária Percutânea , Ásia , Competência Clínica
5.
BMC Cardiovasc Disord ; 15: 153, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26577590

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS) can be a useful tool during drug-eluting stents (DES) implantation as it allows accurate assessment of lesion severity and optimal treatment planning. However, numerous reports have shown that IVUS guided percutaneous coronary intervention is not associated with improved clinical outcomes, especially in non-complex patients and lesions. METHODS: We searched the literature in Medline, the Cochrane Library, and other internet sources to identify studies that compare clinical outcomes between IVUS-guided and angiography-guided DES implantation. Random-effects model was used to assess treatment effect. RESULTS: Twenty eligible studies with a total of 29,068 patients were included in this meta-analysis. The use of IVUS was associated with significant reductions in major adverse cardiovascular events (MACE, odds ratios [OR] 0.77, 95 % confidence intervals [CI] 0.71-0.83, P < 0.001), death (OR 0.62, 95 % CI 0.54-0.71, p < 0.001), and stent thrombosis (OR 0.59, 95 % CI: 0.47-0.73, P < 0.001). The benefit was also seen in the repeated analysis of matched and randomized studies. In stratified analysis, IVUS guidance appeared to be beneficial not only in patients with complex lesions or acute coronary syndromes (ACS) but also patients with mixed lesions or presentations (MACE: OR 0.69, 95 % CI: 0.60-0.79, p < 0.001, OR 0.81, 95 % CI 0.74-0.90, p < 0.001, respectively). By employing meta-regression analysis, the benefit of IVUS is significantly pronounced in patients with complex lesions or ACS with respect to death (p = 0.048). CONCLUSIONS: IVUS guidance was associated with improved clinical outcomes, especially in patients with complex lesions admitted with ACS. Large, randomized clinical trials are warranted to identify populations and lesion characteristics where IVUS guidance would be associated with better outcomes.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Ultrassonografia de Intervenção , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Pontuação de Propensão , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
7.
Cardiovasc Ultrasound ; 11: 25, 2013 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-23870248

RESUMO

PURPOSE: To evaluate the atherosclerotic evolution in coronary bifurcations located proximally and distally to a bioresorbable scaffold. METHODS: Thirty bifurcations located >5 mm beyond the scaffolded segment, being investigated with serial intravascular ultrasound virtual histology (IVUS-VH) examinations, at baseline and 2-years, in patients enrolled in the ABSORB cohort B1 study were included in this analysis. In each bifurcation, the frames portraying the proximal rim, in-bifurcation, and distal rim of the ostium of the side branch were analyzed. The geometric parameters and plaque types were evaluated at baseline and 2-years follow-up. RESULTS: There were no significant differences in the geometrical parameters such as lumen, vessel and plaque areas as well as in the composition of the atheroma between baseline and 2-years follow-up.When we separately examined the bifurcations located proximally and distally to the scaffolded segment, no changes were found at the distal bifurcations, while at the proximal bifurcations there was a statistical significant decrease in the plaque burden (36.67 ± 13.33% at baseline vs. 35.06 ± 13.20% at 2 years follow-up, p = 0.04).Ten necrotic core rich plaques were found at baseline, of which 2 regressed to either fibrotic plaque or to intimal thickening at 2 years follow-up. The other 8 did not change. Disease progression was noted in 3 plaques (1 adaptive intimal thickening, 1 fibrotic and 1 fibrocalcific plaque) that evolved to necrotic rich plaques. CONCLUSIONS: Plaque regression was noted at the bifurcations located proximally to the bioresorbable scaffold but not at these located distally. Additional studies are required to confirm this finding and examine further the effect of drug elution on atherosclerotic evolution.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Ecocardiografia/métodos , Sirolimo/análogos & derivados , Ultrassonografia de Intervenção/métodos , Idoso , Estenose Coronária , Everolimo , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imunossupressores/administração & dosagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Sirolimo/administração & dosagem , Técnica de Subtração , Resultado do Tratamento , Interface Usuário-Computador
8.
Catheter Cardiovasc Interv ; 79(6): 890-902, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-21523891

RESUMO

OBJECTIVE: To report the agreement between gray-scale intravascular ultrasound (GS-IVUS) and optical coherence tomography (OCT) in assessing the bioresorbable vascular scaffolds (BVS) structures and their respective reproducibility. BACKGROUND: BVS are composed of an erodible polymer. Ultrasound and light signals backscattered from polymeric material differs from metallic stents using GS-IVUS and OCT. METHODS: Forty-five patients included in the ABSORB trial were treated with a 3.0 × 18 mm BVS and imaged with GS-IVUS 20 MHz and OCT post-implantation. Qualitative (ISA, side-branch struts, protrusion, and dissections) and quantitative (number of struts, lumen, and scaffold area) measurements were assessed by two investigators. The agreement and the inter- and intraobserver reproducibility were investigated using the kappa (κ) and the interclass correlation coefficient (ICC). RESULTS: GS-IVUS and OCT agreement was predominantly poor at a lesion, frame, and strut level analysis (κ and ICC <0.4) for qualitative measurements. GS-IVUS demonstrated a reduced ability to detect cross-sections with ISA (4.5% vs. 20.6%), side-branch (SB) struts (6.3% vs. 7.8%), protrusions (3.2% vs. 9.6%), and dissections (0.2% vs. 9.0%) compared with OCT. GS-IVUS reproducibility was poor-moderate (κ and ICC <0.6) except for ISA and SB-struts (κ and ICC between 0.2 and 0.75). OCT showed an excellent reproducibility (κ and ICC > 0.75) except for the assessment of tissue protrusion (κ and ICC between 0.47 and 0.94). GS-IVUS reproducibility was poor-moderate (ICC ≤ 0.5) in assessing the number of struts but excellent with OCT (ICC > 0.85). The reproducibility to assess lumen and scaffold areas was excellent using both techniques (ICC > 0.85). CONCLUSIONS: GS-IVUS has a poor capacity to detect qualitative findings post-BVS implantation and its reproducibility is low compared with OCT. The use of GS-IVUS should be limited when assessing lumen and scaffold areas.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Isquemia Miocárdica/terapia , Sirolimo/análogos & derivados , Alicerces Teciduais , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Portadores de Fármacos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 79(6): 880-8, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22514149

RESUMO

OBJECTIVES: Due to the limited distensibility of the everolimus-eluting bioresorbable vascular scaffold (ABSORB) compared to metallic platform stents, quantitative coronary arteriography (QCA) is a mandatory requirement for ABSORB deployment in the on-going ABSORB EXTEND Single-Arm Study. Visual assessment of vessel size in the ABSORB Cohort B study often lead to under and over-sizing of the 3 mm ABSORB in coronary vessels (recommended range of the vessel diameter ≥ 2.5 mm and ≤ 3.3 mm), with an increased risk of spontaneous incomplete scaffold apposition post ABSORB deployment. We report whether mandatory QCA assessment of vessel size pre-implantation, utilizing the maximal luminal diameter (Dmax) and established interpolated reference vessel diameter (RVD) measurements, has improved device/vessel sizing. METHODS: Pre-implantation post-hoc QCA analyses of all 101 patients from ABSORB Cohort B (102 lesions) and first consecutive 101 patients (108 lesions) from ABSORB EXTEND were undertaken by an independent core-laboratory; all patients had a 3 mm ABSORB implanted. Comparative analyses were performed. RESULTS: Within ABSORB Cohort B, a greater number of over-sized vessels (> 3.3 mm) were identified utilizing the Dmax compared to the interpolated RVD (17 vessels, 16.7% vs. 3 vessels, 2.9%; P = 0.002). Comparative analyses demonstrated a greater number of appropriate vessel-size selection (75 vessels, 69.4% vs. 48 vessels, 47.1%; P = 0.001), a trend towards a reduction in implantation in small (< 2.5 mm) vessels (29 vessels, 26.9% vs. 40 vessels, 39.2%; P = 0.057) and a significant decrease in the implantation in large (> 3.3 mm) vessels (4 vessels, 3.7% vs. 17 vessels, 16.7%; P = 0.002) in ABSORB EXTEND. Bland-Altman plots suggested a good agreement between operator and core-laboratory calculated Dmax measurements. CONCLUSIONS: The introduction of mandatory Dmax measurements of vessel size prior to ABSORB implantation significantly reduced the under-sizing of the 3.0 mm scaffold in large vessels validating the use of this technique in vessel sizing prior to ABSORB implantation.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Isquemia Miocárdica/terapia , Sirolimo/análogos & derivados , Alicerces Teciduais , Angioplastia Coronária com Balão/efeitos adversos , Distribuição de Qui-Quadrado , Portadores de Fármacos , Everolimo , Humanos , Isquemia Miocárdica/diagnóstico por imagem , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
10.
Circ J ; 76(7): 1616-23, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22531596

RESUMO

BACKGROUND: Implantation of a metallic prosthesis creates local stiffness with a subsequent mismatch in the compliance of the vessel wall, disturbances in flow and heterogeneous distribution of wall shear stress. Polymeric bioresorbable ABSORB scaffolds have less stiffness than metallic platform stents. We sought to analyze the mismatch in vascular compliance after ABSORB implantation and its long-term resolution with bioresorption. METHODS AND RESULTS: A total of 83 patients from the ABSORB trials underwent palpography investigations (30 and 53 patients from ABSORB Cohorts A and B, respectively) to measure the compliance of the scaffolded and adjacent segments at various time points (from pre-implantation up to 24 months). The mean of the maximum strain values was calculated per segment by utilizing the Rotterdam Classification (ROC) score and expressed as ROC/mm. Scaffold implantation lead to a significant decrease in vascular compliance (median [IQR]) at the scaffolded segment (from 0.37 [0.24-0.45] to 0.14 [0.09-0.23], P<0.001) with mismatch in compliance in a paired analysis between the scaffolded and adjacent segments (proximal: 0.23 [0.12-0.34], scaffold: 0.12 [0.07-0.19], distal: 0.15 [0.05-0.26], P=0.042). This reported compliance mismatch disappears at short- and mid-term follow-up. CONCLUSIONS: The ABSORB scaffold decreases vascular compliance at the site of scaffold implantation. A compliance mismatch is evident immediately post-implantation and in contrast to metallic stents disappears in the mid-term, likely leading to a normalization of the rheological behavior of the scaffolded segment.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Circulação Coronária , Vasos Coronários/fisiopatologia , Stents Farmacológicos , Hemodinâmica , Poliésteres/química , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Fenômenos Biomecânicos , Fármacos Cardiovasculares/administração & dosagem , Complacência (Medida de Distensibilidade) , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
11.
Eur Heart J ; 32(3): 294-304, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21123276

RESUMO

AIMS: The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT). METHODS AND RESULTS: A total of 12 lesions treated with the BVS 1.0 and 12 selected lesions treated with the revised BVS 1.1 were imaged at baseline and 6-month follow-up with OCT. Late shrinkage and neointimal area (NIA) were derived from OCT area measurements. Neointimal thickness was measured in each strut. Strut appearance has been classified as previously described. Baseline clinical, angiographic, and OCT characteristics were mainly similar in the two groups. At 6 months, absolute and relative shrinkages were significantly larger for the BVS 1.0 than for the BVS 1.1 (0.98 vs. 0.07 mm² and 13.0 vs. 1.0%, respectively; P = 0.01). Neointimal area was significantly higher in the BVS 1.0 than in the BVS 1.1 (in-scaffold area obstruction of 23.6 vs. 12.3%; P < 0.01). Neointimal thickness was also larger in the BVS 1.0 than in the BVS 1.1 (166.0 vs. 76.4 µm; P < 0.01). Consequently, OCT, intravascular ultrasound, and angiographic luminal losses were higher with the BVS 1.0 than with the BVS 1.1. At 6 months, strut appearance was preserved in only 2.9% of the BVS 1.0 struts, but remained unchanged with the BVS 1.1 indicating different state of strut microstucture and/or their reflectivity. CONCLUSION: The BVS 1.1 has less late shrinkage and less neointimal growth at 6-month follow-up compared with the BVS 1.0. A difference in polymer degradation leading to changes in microstructure and reflectivity is the most plausible explanation for this finding.


Assuntos
Stents Farmacológicos/normas , Imunossupressores/administração & dosagem , Isquemia Miocárdica/diagnóstico por imagem , Sirolimo/análogos & derivados , Tomografia de Coerência Óptica/métodos , Idoso , Materiais Biocompatíveis/normas , Prótese Vascular/normas , Angiografia Coronária/métodos , Everolimo , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/terapia , Desenho de Prótese , Falha de Prótese , Sirolimo/administração & dosagem , Alicerces Teciduais , Ultrassonografia de Intervenção
12.
Catheter Cardiovasc Interv ; 77(3): 435-8, 2011 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-21328684

RESUMO

Transcatheter aortic valve implantation (TAVI) has nowadays replaced open heart surgery as an alternative therapeutic tool in selected patients. Thirty-five percent of patients with severe degenerative aortic valve stenosis (AS) remain untreated because of the existing comorbidities that increase their perioperative risk. TAVI is a relatively new technique that has "come to stay" in the everyday clinical practice considering, that is the only alternative to surgery and appears to have excellent long term results. Herein, we describe a vascular complication immediately after the implantation of the Edwards SAPIEN (Edwards Lifesciences, Irvine, CA) prosthesis, followed by ad hoc percutaneous coronary intervention.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Oclusão Coronária/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Doença Aguda , Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Stents , Resultado do Tratamento
13.
Coron Artery Dis ; 32(2): 105-111, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33060524

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the association of diabetes mellitus (DM) with neointimal formation after implantation of second-generation drug-eluting stent (DES) visualized by optical coherence tomography (OCT). METHODS: Patients with single de novo coronary artery disease treated with second-generation DES between June 2014 and June 2017 in our department underwent OCT examination at 1-year follow-up and were enrolled in this retrospective study. The primary end point was in-stent mean neointimal thickness (MNT), and secondary end points included uncovered stent strut, minimal lumen area (MLA), neointimal burden, neointimal hyperplasia (NIH) patterns and stent thrombosis (ST) after 1 year of OCT follow-up. RESULTS: A total of 68 patents with DM (DM group) and 216 patients without DM (non-DM group) were enrolled. At 1-year follow-up, the DM group compared with the non-DM group, showed: MNT [160 (85-245) µm vs. 120 (60-220) µm, P = 0.038] and neointimal burden [21.4 (8.3-30.1)% vs. 14.0 (5.7-26.1)%, P = 0.023] to be significantly increased. Concurrently, MLA [4.60 (3.53-6.06) mm vs. 5.76 (4.28-7.20) mm2, P = 0. 0.002] was significantly reduced. Interestingly, the degree of uncovered struts (7.3 ± 7.1% vs. 7.7 ± 6.7%, P = 0.704), NIH patterns (P = 0.984), and ST (7.9% vs. 7.4%, P = 0.88) were comparable between the two groups. After propensity score matching, the MNT [160 (90-240) µm vs. 110 (60-220) µm, P = 0.048] and neointimal burden [21.4 (8.3-30.1)% vs. 15.4 (5.6-26.3)%, P = 0.044] remained significantly different in the DM compared to the non-DM group. CONCLUSION: DM leads to significant increase in MNT and neointimal burden even with second-generation DES, nevertheless stent strut coverage, ST and NIH characteristics remained comparable among the cohorts at 1-year.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/tratamento farmacológico , Diabetes Mellitus , Stents Farmacológicos , Neointima/patologia , Tomografia de Coerência Óptica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos
14.
Cardiol J ; 28(2): 223-234, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-31702046

RESUMO

BACKGROUND: Current guidelines recommend newer generation drug-eluting stents (DES) over bare-metal stents (BMS) in patients with ischemic heart disease. However, there is no age-specific recommendation in elderly patients. METHODS: Meta-analysis was performed of 6 randomized studies enrolling 5,042 elderly patients who underwent percutaneous coronary intervention (PCI) with stent implantation (DES, n = 2,579; BMS, n = 2,463). RESULTS: Combined data indicated a significant reduction in major adverse cardiovascular events (MACEs) with use of DES (odds ratio [OR] 0.56, 95% confidence interval [CI] 0.44-0.71, p < 0.001). Moreover, use of DES was associated with a significantly lower incidence of myocardial infarction (OR 0.54, 95% CI 0.36-0.81, p = 0.003) and repeat revascularization (OR 0.44, 95% CI 0.31-0.62, p < 0.001), was compared to that with the use of BMS. Stent thrombosis and bleeding complication rates were not significantly different between groups. In a subgroup meta-analysis, short duration (1 or 6 months) dual antiplatelet therapy (DAPT) was associated with a significantly lower MACE rate (OR 0.49, 95% CI 0.34-0.80; p = 0.003) in elderly patients who underwent PCI with everolimuseluting stent implantation, compared with that using long duration DAPT. CONCLUSIONS: This meta-analysis provides clinically relevant evidence that DES rather than BMS should be selected for elderly patients.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Idoso , Humanos , Masculino , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Stents , Resultado do Tratamento
15.
Cardiovasc Revasc Med ; 21(12): 1596-1605, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32546382

RESUMO

Coronary artery bypass surgery has been the accepted treatment for left main coronary artery disease for over 50 years. Balloon angioplasty was later used then abandoned because of deaths likely due to restenosis or thrombotic occlusion. However, rapid innovations in drug-eluting stent designs leading to more biocompatible thin strut platforms with optimal drug elution profiles and further advances in modern pharmacotherapy involving potent P2Y12 inhibitors combined with utilization of intracoronary imaging and physiologic assessment for procedural planning and optimization have transformed percutaneous interventions into successful alternatives to coronary artery bypass graft surgery (CABG) in selected LM anatomic territories. Herein, we provide an evidence-based practical guide on how to approach and perform LM percutaneous interventions (PCI).


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Ponte de Artéria Coronária , Stents Farmacológicos , Humanos , Resultado do Tratamento
16.
PLoS One ; 15(7): e0235673, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32645029

RESUMO

BACKGROUND AND OBJECTIVES: This study sought to compare clinical outcomes between bioresorbable scaffolds (BRS) and durable polymer everolimus-eluting metallic stents (DP-EES) in patients with acute myocardial infarction (AMI) undergoing successful percutaneous coronary intervention (PCI). METHODS: From March 2016 to October 2017, 952 patients with AMI without cardiogenic shock undergoing successful PCI with BRS (n = 136) or DP-EES (n = 816) were enrolled from a multicenter, observational Korea Acute Myocardial Infarction Registry. RESULTS: In the crude population, there was no significant difference in the 1-year rate of device-oriented composite endpoint (DOCE) and device thrombosis between the BRS and DP-EES groups (2.2% vs. 4.8%, hazard ratio [HR] 0.43, 95% confidence interval [CI] 0.13-1.41, p = 0.163; 0.7% vs. 0.5%, HR 1.49, 95% CI 0.16-13.4, p = 0.719, respectively). BRS implantation was opted in younger patients (53.7 vs. 62.6 years, p < 0.001) with low-risk profiles, and intravascular image-guided PCI was more preferred in the BRS group (60.3% vs. 27.2%, p < 0.001). CONCLUSIONS: At 1-year follow-up, no differences in the rate of DOCE and device thrombosis were observed between patients with AMI treated with BRS and those treated with DP-EES. Our data suggest that imaging-guided BRS implantation in young patients with low risk profiles could be a reasonable strategy in the setting of AMI.


Assuntos
Implantes Absorvíveis/efeitos adversos , Stents Farmacológicos/efeitos adversos , Infarto do Miocárdio/cirurgia , Intervenção Coronária Percutânea/efeitos adversos , Doença Aguda/terapia , Adulto , Idoso , Fármacos Cardiovasculares/uso terapêutico , Determinação de Ponto Final , Everolimo/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Modelos de Riscos Proporcionais , República da Coreia , Trombose/etiologia , Alicerces Teciduais/efeitos adversos , Resultado do Tratamento
17.
EuroIntervention ; 16(12): e989-e996, 2020 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-32091401

RESUMO

AIMS: The Absorb bioresorbable vascular scaffold (BVS) has high rates of target lesion failure (TLF) at three years. Low wall shear stress (WSS) promotes several mechanisms related to device TLF. We investigated the impact of BVS compared to XIENCE V (XV) on coronary WSS after device deployment. METHODS AND RESULTS: In the prospective, randomised, controlled ABSORB III Imaging study (BVS [n=77] or XV [n=36]), computational fluid dynamics were performed on fused angiographic and intravascular ultrasound (IVUS) images of post-implanted vessels. Low WSS was defined as <1 Pa. There were no differences in demographics, clinical risks, angiographic reference vessel diameter or IVUS minimal lumen diameter between BVS and XV patients. A greater proportion of vessels treated with BVS compared to XV demonstrated low WSS across the whole device (BVS: 17/77 [22%] vs XV: 2/36 [6%], p<0.029). Compared to XV, BVS demonstrated lower median circumferential WSS (1.73 vs 2.21 Pa; p=0.036), outer curvature WSS (p=0.026), and inner curvature WSS (p=0.038). Similarly, BVS had lower proximal third WSS (p=0.024), middle third WSS (p=0.047) and distal third WSS (p=0.028) when compared to XV. In a univariable logistic regression analysis, patients who received BVS were 4.8 times more likely to demonstrate low WSS across the scaffold/stent when compared to XV patients. Importantly, in a multivariable linear regression model, hypertension (beta: 0.186, p=0.023), lower contrast frame count velocity (beta: -0.411, p<0.001), lower post-stent residual plaque burden (beta: -0.338, p<0.001), lower % underexpanded frames (beta: -0.170, p=0.033) and BVS deployment (beta: 0.251, p=0.002) remained independently associated with a greater percentage of stented coronary vessel areas exposed to low WSS. CONCLUSIONS: In this randomised controlled study, the Absorb BVS was 4.8 times more likely than the XV metallic stent to demonstrate low WSS. BVS implantation, lower blood velocity and lower residual post-stent plaque burden were independently associated with greater area of low WSS.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Everolimo/uso terapêutico , Humanos , Estudos Prospectivos , Desenho de Prótese , Stents , Resultado do Tratamento
19.
EuroIntervention ; 13(16): 1904-1913, 2018 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-29278353

RESUMO

AIMS: The aim of this study was to investigate the long-term safety and efficacy of biodegradable scaffolds and metallic stents. METHODS AND RESULTS: We analysed a total of 91 randomised controlled trials with a mean follow-up of 3.7 years in 105,842 patients which compared two or more coronary metallic stents or biodegradable scaffolds and reported the long-term clinical outcomes (≥2 years). Network meta-analysis showed that patients treated with the Absorb bioresorbable vascular scaffold (BVS) had a significantly higher risk of definite or probable scaffold thrombosis (ScT) compared to those treated with metallic DES. The risk of very late ScT was highest with the Absorb BVS among comparators. Pairwise conventional meta-analysis demonstrated that the elevated risk of ScT with Absorb BVS compared to cobalt-chromium everolimus-eluting stents was consistent across the time points of ≤30 days (early), 31 days - 1 year (late) and >1 year (very late) ScT. In addition, target lesion failure rates were significantly higher in the Absorb BVS cohort, driven by both increased risk of target vessel myocardial infarction and ischaemia-driven target lesion revascularisation. CONCLUSIONS: Absorb BVS implantation was associated with increased risk of long-term and very late ScT compared to current-generation metallic DES. The risk of ScT occurred with a rising trend beyond one year.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/cirurgia , Metais , Intervenção Coronária Percutânea/instrumentação , Stents , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Humanos , Segurança do Paciente , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
20.
J Am Coll Cardiol ; 72(24): 3126-3137, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30261237

RESUMO

BACKGROUND: Intravascular ultrasound (IVUS)-guided drug-eluting stent (DES) implantation is associated with fewer major adverse cardiovascular events compared with angiography guidance for patients with individual lesion subset. However, the beneficial effect on major adverse cardiovascular event outcome of IVUS guidance over angiography guidance in all-comers who undergo DES implantation still remains understudied. OBJECTIVES: This study aimed to determine the benefits of IVUS guidance over angiography guidance during DES implantation in all-comer patients. METHODS: A total of 1,448 all-comer patients who required DES implantation were randomly assigned (1:1 ratio) to either an IVUS guidance or angiography guidance group. The primary endpoint was target-vessel failure (TVF) at 12 months, including cardiac death, target-vessel myocardial infarction, and clinically driven target-vessel revascularization (TVR). The procedure was defined as a success if all IVUS-defined optimal criteria were met. RESULTS: At 12 months follow-up, 60 TVFs (4.2%) occurred, with 21 (2.9%) in the IVUS group and 39 (5.4%) in the angiography group (hazard ratio [HR]: 0.530; 95% confidence interval [CI]: 0.312 to 0.901; p = 0.019). In the IVUS group, TVF was recorded in 1.6% of patients with successful procedures, compared with 4.4% in patients who failed to achieve all optimal criteria (HR: 0.349; 95% CI: 0.135 to 0.898; p = 0.029). The significant reduction of clinically driven target-lesion revascularization or definite stent thrombosis (HR: 0.407; 95% CI: 0.188 to 0.880; p = 0.018) based on lesion-level analysis by IVUS guidance was not achieved when the patient-level analysis was performed. CONCLUSIONS: The present study demonstrates that IVUS-guided DES implantation significantly improved clinical outcome in all-comers, particularly for patients who had an IVUS-defined optimal procedure, compared with angiography guidance. (Intravascular Ultrasound Guided Drug Eluting Stents Implantation in "All-Comers" Coronary Lesions [ULTIMATE]; NCT02215915).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Radiografia Intervencionista , Ultrassonografia de Intervenção , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA