1.
J AOAC Int ; 98(3): 767-783, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26086256

RESUMO

The 3M™ Petrifilm™ Rapid Yeast and Mold (RYM) Count Plate is a simple, ready-to-use chromogenic culture method for the rapid detection and enumeration of yeast and mold in food products. The 3M Petrifilm RYM Count Plate method was compared to the U. S. Food and Drug Administration Bacteriological Analytical Manual (FDA BAM) Chapter 18, Yeasts, Molds and Mycotoxins and the ISO 21527:2008 Microbiology of Food and Animal Feeding Stuffs-Horizontal Method for the Enumeration for Yeast and Molds - Part 1: Colony Count Technique in Products with Water Activity Greater Than 0.95 and Part 2: Colony Count Technique in Products with Water Activity Less Than or Equal to 0.95 reference methods for raw almonds and raw frozen ground beef patties (77% lean). The 3M Petrifilm RYM Count Plate method was evaluated using a paired study design in a multi-laboratory collaborative study following the current AOAC Validation Guidelines. Three target contamination levels (low, 10-100 CFU/g; medium, 100-1000 CFU/g; high 1000-10 000 CFU/g) as well as an uninoculated control level (0 CFU/g) were evaluated for each matrix. Samples evaluated by the 3M Petrifilm RYM Count Plate method were prepared in duplicate and incubated at both 25°C and 28°C. Plates at both temperatures were enumerated after 48 and 60 h of incubation. No significant difference was observed between the 3M Petrifilm RYM Count Plate method and the FDA BAM or ISO 21527 reference methods for each contamination level. No statistical differences were observed between samples analyzed by the 3M Petrifilm RYM Count Plate method (at either 25°C or 28°C) and the reference methods. No statistical significant differences were observed between enumeration of colonies at 48 and 60 h on the 3M Petrifilm RYM Count Plate method and the reference methods.


Assuntos
Contagem de Colônia Microbiana/métodos , Microbiologia de Alimentos/instrumentação , Fungos/crescimento & desenvolvimento , Leveduras/crescimento & desenvolvimento , Animais , Bovinos , Microbiologia de Alimentos/métodos , Carne/microbiologia , Prunus/microbiologia , Manejo de Espécimes
2.
J AOAC Int ; 98(4): 980-92, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26268981

RESUMO

The 3M™ Molecular Detection Assay (MDA) Listeria monocytogenes combines isothermal amplification and bioluminescence to detect Listeria monocytogenes with high specificity and efficiency in select foods and environmental samples. The 3M MDA Listeria monocytogenes method was evaluated using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture, Food Safety and Inspection Service Microbiology Laboratory Guidebook 8.09 (2011) Isolation and Identification of Listeria monocytogenes from Red Meat, Poultry, and Egg Products and Environmental Samples for deli turkey, and the AOAC Official Method of Analysis(SM) 993.12 Listeria monocytogenes in Milk and Dairy Products for full-fat (4% milk fat) cottage cheese following the current AOAC guidelines. A total of 16 laboratories located in the continental United States and Canada participated in this collaborative study. For deli turkey, 125 g test portions were evaluated using heat-stressed cells by each method. For full-fat cottage cheese, 25 g test portions were evaluated using nonheat-stressed cells. Each matrix had three inoculation levels: an uninoculated control level (0 CFU/test portion), and two levels artificially contaminated with L. monocytogenes, a low inoculum level (0.2-2 CFU/test portion) and a high inoculum level (2-5 CFU/test portion). In total, 1584 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD) model. Results obtained for the low inoculum level full-fat cottage cheese test portions produced a difference in cross-laboratory POD (dLPOD) value of -0.08 with a 95% confidence interval (CI) of (-0.20, 0.05). For the low-level deli turkey test portions, a dLPOD value of -0.02 with a 95% CI of (-0.14, 0.11) was obtained.


Assuntos
Microbiologia Ambiental , Microbiologia de Alimentos , Listeria monocytogenes/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Comportamento Cooperativo , Medições Luminescentes
3.
J AOAC Int ; 98(4): 993-1002, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26268982

RESUMO

The 3M™ Molecular Detection Assay (MDA) Listeria is used with the 3M Molecular Detection System for the detection of Listeria species in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Listeria target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Listeria method was evaluated using an unpaired study design in a multilaboratory collaborative study and compared to the AOAC Official Method of AnalysisSM (OMA) 993.12 Listeria monocytogenes in Milk and Dairy Products reference method for the detection of Listeria species in full-fat (4% milk fat) cottage cheese (25 g test portions). A total of 15 laboratories located in the continental United States and Canada participated. Each matrix had three inoculation levels: an uninoculated control level (0 CFU/test portion), and two levels artificially contaminated with Listeria monocytogenes, a low inoculum level (0.2-2 CFU/test portion) and a high inoculum level (2-5 CFU/test portion) using nonheat-stressed cells. In total, 792 unpaired replicate portions were analyzed. Statistical analysis was conducted according to the probability of detection (POD) model. Results obtained for the low inoculum level test portions produced a difference in cross-laboratory POD value of -0.07 with a 95% confidence interval of (-0.19, 0.06). No statistically significant differences were observed in the number of positive samples detected by the 3M MDA Listeria method versus the AOAC OMA method.


Assuntos
Microbiologia Ambiental , Microbiologia de Alimentos , Listeria/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Comportamento Cooperativo
4.
J AOAC Int ; 98(5): 1301-14, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26525249

RESUMO

The Thermo Scientific™ SureTect™ Escherichia coli O157:H7 Assay is a new real-time PCR assay which has been validated through the AOAC Research Institute (RI) Performance Tested Methods(SM) program for raw beef and produce matrixes. This validation study specifically validated the assay with 375 g 1:4 and 1:5 ratios of raw ground beef and raw beef trim in comparison to the U.S. Department of Agriculture, Food Safety Inspection Service, Microbiology Laboratory Guidebook (USDS-FSIS/MLG) reference method and 25 g bagged spinach and fresh apple juice at a ratio of 1:10, in comparison to the reference method detailed in the International Organization for Standardization 16654:2001 reference method. For raw beef matrixes, the validation of both 1:4 and 1:5 allows user flexibility with the enrichment protocol, although which of these two ratios chosen by the laboratory should be based on specific test requirements. All matrixes were analyzed by Thermo Fisher Scientific, Microbiology Division, Vantaa, Finland, and Q Laboratories Inc, Cincinnati, Ohio, in the method developer study. Two of the matrixes (raw ground beef at both 1:4 and 1:5 ratios) and bagged spinach were additionally analyzed in the AOAC-RI controlled independent laboratory study, which was conducted by Marshfield Food Safety, Marshfield, Wisconsin. Using probability of detection statistical analysis, no significant difference was demonstrated by the SureTect kit in comparison to the USDA FSIS reference method for raw beef matrixes, or with the ISO reference method for matrixes of bagged spinach and apple juice. Inclusivity and exclusivity testing was conducted with 58 E. coli O157:H7 and 54 non-E. coli O157:H7 isolates, respectively, which demonstrated that the SureTect assay was able to detect all isolates of E. coli O157:H7 analyzed. In addition, all but one of the nontarget isolates were correctly interpreted as negative by the SureTect Software. The single isolate giving a positive result was an E. coli O157:NM isolate. Nonmotile isolates of E. coli O157 have been demonstrated to still contain the H7 gene; therefore, this result is not unexpected. Robustness testing was conducted to evaluate the performance of the SureTect assay with specific deviations to the assay protocol, which were outside the recommended parameters and which are open to variation. This study demonstrated that the SureTect assay gave reliable performance. A final study to verify the shelf life of the product, under accelerated conditions was also conducted.


Assuntos
Escherichia coli O157/genética , Análise de Alimentos/métodos , Carne/análise , Alimentos Crus/análise , Reação em Cadeia da Polimerase em Tempo Real/normas , Animais , Bovinos , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Humanos , Alimentos Crus/microbiologia , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Spinacia oleracea/microbiologia
5.
J AOAC Int ; 97(6): 1563-75, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25632434

RESUMO

The 3M™ Petriflm™ Salmonella Express (SALX) System is a simple, ready-to-use chromogenic culture medium system for the rapid qualitative detection and biochemical confirmation of Salmonella spp. in food and food process environmental samples. The 3M Petrifilm SALX System was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.07 (2013) Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products and Carcass and Environmental Sponges for raw ground beef and the U.S. Food and Drug Administration Bacteriological Analytical Manual (FDA/BAM) Chapter 5, Salmonella (2011) reference method for dry dog food following the current AOAC validation guidelines. For this study, a total of 17 laboratories located throughout the continental United States evaluated 1872 test portions. For the 3M Petrifilm SALX System, raw ground beef was analyzed using 25 g test portions, and dry dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each inatrix were analyzed. The two matrices were artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). Each inoculation level was statistically analyzed using the probability of detection statistical model. For the raw ground beef and dry dog food test portions, no significant differences at the 95% confidence interval were observed in the number of positive samples detected by the 3M Petrifilm SALX System versus either the USDA/FSIS-MLG or FDA/BAM methods.


Assuntos
Ração Animal/microbiologia , Contagem de Colônia Microbiana/instrumentação , Análise de Alimentos/instrumentação , Microbiologia de Alimentos , Carne/microbiologia , Salmonella/isolamento & purificação , Animais , Bovinos , Cães , Probabilidade , Reprodutibilidade dos Testes
6.
J AOAC Int ; 97(2): 431-41, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24830156

RESUMO

The VIDAS UP Listeria (LPT) is an automated rapid screening enzyme phage-ligand based assay for the detection of Listeria species in human food products and environmental samples. The VIDAS LPT method was compared in a multi-laboratory collaborative study to AOAC Official Method 993.12 Listeria monocytogenes in Milk and Dairy Products reference method following current AOAC guidelines. A total of 14 laboratories participated, representing government and industry, throughout the United States. One matrix, queso fresco (soft Mexican cheese), was analyzed using two different test portion sizes, 25 and 125 g. Samples representing each test portion size were artificially contaminated with Listeria species at three levels, an uninoculated control level [0 colony-forming units (CFU)/test portion], a low-inoculum level (0.2-2 CFU/test portion), and a high-inoculum level (2-5 CFU/test portion). For this evaluation, 1800 unpaired replicate test portions were analyzed by either the VIDAS LPT or AOAC 993.12. Each inoculation level was analyzed using the Probability of Detection (POD) statistical model. For the low-level inoculated test portions, difference in collaborator POD (dLPOD) values of 0.01, (-0.10, 0.13), with 95% confidence intervals, were obtained for both 25 and 125 g test portions. The range of the confidence intervals for dLPOD values for both the 25 and 125 g test portions contains the point 0.0 indicating no statistically significant difference in the number of positive samples detected between the VIDAS LPT and the AOAC methods. In addition to Oxford agar, VIDAS LPT test portions were confirmed using Agar Listeria Ottavani and Agosti (ALOA), a proprietary chromogenic agar for the identification and differentiation of L. monocytogenes and Listeria species. No differences were observed between the two selective agars. The VIDAS LPT method, with the optional ALOA agar confirmation method, was adopted as Official First Action status for the detection of Listeria species in a variety of foods and environmental samples.


Assuntos
Técnicas Bacteriológicas/métodos , Microbiologia Ambiental , Microbiologia de Alimentos/métodos , Listeria/isolamento & purificação , Animais , Automação , Técnicas Bacteriológicas/normas , Compostos Cromogênicos , Meios de Cultura , Microbiologia de Alimentos/normas , Reprodutibilidade dos Testes
7.
J AOAC Int ; 97(2): 442-52, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24830157

RESUMO

The VIDAS Listeria monocytogenes Xpress (LMX) is an automated rapid screening enzyme immunoassay for the detection of Listeria monocytogenes in food products. The VIDAS LMX method was compared in a multi-laboratory collaborative study to AOAC Official Method 993.12 Listeria monocytogenes in Milk and Dairy Products reference method following current AOAC guidelines. A total of 14 laboratories participated, representing government and industry, throughout the United States. One matrix, queso fresco (soft Mexican cheese), was analyzed using two different test portion sizes, 25 and 125 g. Samples representing each portion size were artificially contaminated with L. monocytogenes at three levels: an uninoculated control level [0 colony forming units (CFU)/test portion], a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). For this evaluation, 1800 unpaired replicate test portions were analyzed by either the VIDAS LMX or AOAC 993.12. Each level was analyzed using the Probability of Detection (POD) statistical model. For the low-level inoculated test portions, difference in collaborator POD (dLPOD) values of 0.04, (-0.08, 0.15) and 0.01, (-0.10, 0.13), with 95% confidence intervals, were obtained, respectively, for 25 and 125 g test portions. The range of the confidence intervals for dLPOD values for both the 25 and 125 g test portions contain the point 0.0 indicating no statistically significant difference in the number of positive samples detected between the VIDAS LMX and the AOAC method. In addition to Oxford Agar (OXA), VIDAS LMX test portions were confirmed using Agar Listeria Ottavani and Agosti (ALOA), a proprietary chromogenic agar for the identification and differentiation of L. monocytogenes and Listeria species. No differences were observed between the two selective agars. The VIDAS LMX method, with the optional ALOA agar confirmation method, was adopted as Official First Action status for the detection of L. monocytogenes in a variety of foods.


Assuntos
Técnicas Bacteriológicas/instrumentação , Técnicas Bacteriológicas/métodos , Microbiologia de Alimentos/métodos , Listeria monocytogenes/isolamento & purificação , Automação , Técnicas Bacteriológicas/normas , Laticínios/microbiologia , Microbiologia de Alimentos/normas , Técnicas Imunoenzimáticas/métodos
8.
J AOAC Int ; 97(3): 868-75, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25051636

RESUMO

A multilaboratory study was conducted to evaluate the ability of the DuPont BAX System Real-Time PCR Assay for Salmonella to detect the target species in a variety of foods and environmental surfaces. Internal validation studies were performed by DuPont Nutrition & Health on 24 different sample types to demonstrate the reliability of the test method among a wide variety of sample types. Two of these matrixes-pork and turkey frankfurters and pasteurized, not-from-concentrate orange juice without pulp-were each evaluated in 14 independent laboratories as part of the collaborative study to demonstrate repeatability and reproducibility of the internal laboratory results independent of the end user. Frankfurter samples were evaluated against the U.S. Department of Agriculture, Food Safety and Inspection Service reference method as a paired study, while orange juice samples were evaluated against the U.S. Food and Drug Administration reference method as an unpaired study, using a proprietary media for the test method. Samples tested in this study were artificially inoculated with a Salmonella strain at levels expected to produce low (0.2-2.0 CFU/test portion) or high (5 CFU/test portion) spike levels on the day of analysis. For each matrix, the collaborative study failed to show a statistically significant difference between the candidate method and the reference method using the probability of detection statistical model.


Assuntos
Técnicas Bacteriológicas/métodos , Microbiologia de Alimentos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Salmonella/isolamento & purificação , Reprodutibilidade dos Testes , Salmonella/genética
9.
J AOAC Int ; 96(6): 1325-35, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24645511

RESUMO

The 3M Molecular Detection Assay (MDA) Salmonella is used with the 3M Molecular Detection System for the detection of Salmonella spp. in food, food-related, and environmental samples after enrichment. The assay utilizes loop-mediated isothermal amplification to rapidly amplify Salmonella target DNA with high specificity and sensitivity, combined with bioluminescence to detect the amplification. The 3M MDA Salmonella method was compared using an unpaired study design in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG 4.05), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products for raw ground beef and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the POD of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive samples detected by the 3M MDA Salmonella method versus either the USDA/FSIS-MLG or FDA/BAM methods.


Assuntos
Ração Animal/microbiologia , Contaminação de Alimentos/análise , Microbiologia de Alimentos/normas , Carne/análise , Salmonella/isolamento & purificação , Algoritmos , Animais , Bovinos , DNA Bacteriano/análise , Inocuidade dos Alimentos , Carne/microbiologia , Óvulo/microbiologia , Aves Domésticas/microbiologia , Padrões de Referência , Reprodutibilidade dos Testes , Células-Tronco , Estados Unidos , United States Department of Agriculture
10.
J AOAC Int ; 96(4): 808-21, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24000757

RESUMO

The VIDAS UP Salmonella (SPT) uses recombinant phage proteins to detect Salmonella species in human and animal food products and production environmental samples after 18-26 h of enrichment. The VIDAS SPT assay is performed with the automated VIDAS or mini-VIDAS instruments. The VIDAS SPT method was compared in a multilaboratory collaborative study to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05 (2011) Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg and Catfish Products reference method following the current AOAC guidelines. A total of 15 laboratories representing government, academia, and industry throughout the United States participated. One matrix, raw ground beef, was analyzed using two different test portion sizes, 25 and 375 g. Each test portion was artificially contaminated with Salmonella at three inoculation levels, an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFUltest portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1656 unpaired replicate samples were analyzed. Of those unpaired replicates, 476 were presumptive positive by the VIDAS method, with 475 confirmed positive by the traditional confirmation procedures and 476 confirmed positive by an alternative confirmation procedure. There were 411 confirmed positive replicates by the USDA/FSIS-MLG reference method. Statistical analysis was conducted according to the probability of detection (POD). For the low-level 375 g test portions, the following dLPOD values, with 95% confidence intervals, were obtained: 0.01 (-0.12, +0.15) for samples confirmed following the traditional confirmation; 0.02 (-0.18, +0.2) for samples confirmed following traditional confirmation on IBISA and ASAP; and 0.03 (-0.18, +0.24) for samples confirmed following the alternative confirmation on IBISA and ASAP. For the low-level 25 g test portions, the following dLPOD values, with 95% confidence intervals, were obtained: 0.41, (0.32, +0.49) for samples confirmed following the traditional confirmation, the traditional confirmation on IBISA and ASAP, and the alternative confirmation on IBISA and ASAP. With 0.0 within the confidence intervals for the 375 g test portions, there was no statistically significant difference in the number of positive samples detected by the VIDAS SPT method and the USDA/FSIS-MLG method at the 0.05 level. For the 25 g test portions, a statistically significant difference was observed between the VIDAS SPT method and the reference method for the low inoculum level, where the VIDAS SPT method recovered a higher number of positive results than the reference method. It is recommended that the VIDAS SPT method with the optional ASAP and IBISA agar confirmation method be adopted for Official First Action status for the detection of Salmonella in a variety of foods and environmental samples.


Assuntos
Microbiologia Ambiental , Microbiologia de Alimentos , Salmonella/isolamento & purificação , Animais , Bovinos , Comportamento Cooperativo , Carne/microbiologia , Probabilidade
11.
J AOAC Int ; 95(5): 1425-32, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23175976

RESUMO

A collaborative study was conducted to evaluate the performance of the VITEK 2 Gram Positive (GP) identification card for use with the VITEK 2 automated microbial identification system. The GP test card is used in the identification of selected Gram positive organisms, including Listeria and Staphylococcus species. The VITEK 2 GP card is based on 43 biochemical tests measuring carbon source utilization, inhibition and resistance, and enzymatic activities. A total of 20 laboratories representing government, industry, and private testing laboratories throughout the United States participated. In this study, 720 Gram-positive inclusivity isolates were analyzed by the GP Identification method. Of the 720 well-characterized isolates, 714 were identified correctly, zero were misidentified, zero were unidentified, and six were not characterized as a Gram-positive organism by the VITEK 2 GP method. Additionally, 120 strains exclusive of Gram-positive organisms were screened by Gram stain. A total of 106 isolates were correctly excluded. Fourteen organisms were incorrectly characterized by Gram stain procedures, thus resulting in improper analysis and misidentification by VITEK GP. The VITEK 2 GP identification method is an acceptable automated method for the rapid identification of selected Gram-positive bacteria.


Assuntos
Técnicas de Tipagem Bacteriana/instrumentação , Técnicas de Tipagem Bacteriana/métodos , Bactérias Gram-Positivas/isolamento & purificação , Infecções por Bactérias Gram-Positivas/diagnóstico , Infecções por Bactérias Gram-Positivas/microbiologia , Humanos , Laboratórios , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade
12.
J AOAC Int ; 95(3): 778-85, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22816270

RESUMO

A collaborative study was conducted to evaluate the performance of the VITEK 2 Gram-negative (GN) Identification card for use with the VITEK 2 automated microbial identification system. The GN test card is used in the identification of fermenting and nonfermenting Gram-negative bacilli, including the select agent organisms Brucella melitensis, Francisella tularensis, Burkholderia mallei, B. pseudomallei, and Yersinia pestis. The VITEK 2 GN card is based on 47 biochemical tests measuring carbon source utilization, inhibition and resistance, and enzymatic activities. A total of 20 laboratories representing government, industry, and private testing facilities throughout the United States participated. In this study, 720 Gram-negative inclusivity isolates were analyzed by the GN Identification method. Of the 720 well-characterized isolates, 707 were identified correctly, 0 were misidentified, 0 were unidentified, and 13 were not characterized as a Gram-negative organism. Additionally, 120 isolates exclusive of fermenting and nonfermenting Gram-negative bacilli were screened by Gram stain. A total of 117 isolates were correctly excluded. Three organisms were incorrectly characterized by Gram stain procedures, resulting in incorrect analysis and misidentification by VITEK 2 GN. The VITEK 2 GN identification method is an acceptable automated method for the rapid identification of Gram-negative bacteria.


Assuntos
Bactérias Gram-Negativas/isolamento & purificação , Comportamento Cooperativo
13.
J AOAC Int ; 94(6): 1821-34, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22320090

RESUMO

The VIDAS Salmonella (SLM) Easy Salmonella method is a specific enzyme-linked fluorescent immunoassay performed in the automated VIDAS instrument. The VIDAS Easy Salmonella method is a simple 2-step enrichment procedure, using pre-enrichment followed by selective enrichment in a newly formulated broth, SX2 broth. This new method was compared in a multilaboratory collaborative study to the U.S. Food and Drug Administration's Bacteriological Analytical Manual, Chapter 5 method for five food matrixes (liquid egg, vanilla ice cream, spinach, raw shrimp, and peanut butter) and the U.S. Department of Agriculture's Microbiology Laboratory Guidebook 4.04 method for deli turkey. Each food type was artificially contaminated with Salmonella at three inoculation levels. A total of 15 laboratories representing government, academia, and industry, throughout the United States, participated. In this study, 1583 samples were analyzed, of which 792 were paired replicates and 791 were unpaired replicates. Of the 792 paired replicates, 285 were positive by both the VIDAS and reference methods. Of the 791 unpaired replicates, 341 were positive by the VIDAS method and 325 were positive by the cultural reference method. A Chi-square analysis of each of the six food types was performed at the three inoculation levels tested. For all foods evaluated, the VIDAS Easy SLM method demonstrated results comparable to those of the reference methods for the detection of Salmonella.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Microbiologia de Alimentos/métodos , Salmonella/isolamento & purificação , Animais , Arachis/microbiologia , Comportamento Cooperativo , Crustáceos/microbiologia , Ovos/microbiologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Fluorescência , Microbiologia de Alimentos/instrumentação , Humanos , Sorvetes/microbiologia , Laboratórios , Produtos Avícolas/microbiologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Spinacia oleracea/microbiologia , Estados Unidos , United States Food and Drug Administration
14.
J AOAC Int ; 93(2): 576-86, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20480906

RESUMO

The automated method for enumeration of Escherichia coli, TEMPO EC, in foods uses a dehydrated culture medium and enumeration card containing 48 wells across three different dilutions for the automatic determination of the most probable number (MPN). The alternative method was compared in a multilaboratory collaborative study to AOAC Official Method 966.24. Six food types were artificially contaminated with E. coli: raw ground beef, bagged lettuce, cooked chicken, pasteurized crabmeat, frozen green beans, and pasteurized whole milk. All foods were analyzed for E. coli counts by 11 collaborating laboratories throughout the United States. Test portions from the six food types each contaminated at four different contamination levels were evaluated. The study demonstrated that the TEMPO EC method is a reliable, automated assay for the enumeration of E. coli in foods.


Assuntos
Contagem de Colônia Microbiana/métodos , Escherichia coli/metabolismo , Contaminação de Alimentos , Microbiologia de Alimentos , Animais , Automação , Bovinos , Galinhas/microbiologia , Análise de Alimentos , Laboratórios/normas , Carne/microbiologia , Reprodutibilidade dos Testes , Projetos de Pesquisa , Alimentos Marinhos/microbiologia , Verduras/microbiologia
15.
J AOAC Int ; 103(2): 513-522, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33241279

RESUMO

BACKGROUND: The 3M™ Petrifilm™ Rapid E. coli/Coliform Count Plate is a selective and differential sample-ready-culture medium designed for the rapid enumeration of Escherichia coli (E. coli) and coliforms in the food and beverage industries. OBJECTIVE: The 3M Petrifilm Rapid E. coli/Coliform Count Plate was compared to the U.S. Food and Drug Administration Bacteriological Analytical Manual (BAM) Chapter 4 Enumeration of Escherichia coli and the Coliform Bacteria, the International Organization of Standards (ISO) 4832:2006 Microbiology of food and animal feeding stuffs - Horizontal method for the enumeration of coliforms-Colony-count technique, and ISO 16649-2:2017 Microbiology of food and animal feeding stuffs-Horizontal method for the enumeration of beta-glucuronidase-positive Escherichia coli-Part 2 Colony-count technique at 44 degrees C using bromo-4-chloro-3- indolyl beta-D-glucuronide methods for the enumeration of E. coli and coliforms in dry dog kibble. METHOD: The candidate method was evaluated using two diluents, Butterfield's phosphate buffered diluent and peptone salt solution, in a paired study design with each reference method in a multi-laboratory collaborative study following the current AOAC Validation Guidelines. Three target contamination levels and an uninoculated control level were evaluated. RESULTS: The candidate and reference methods were not statistically different at each contamination level. Reproducibility values obtained during the collaborative study were similar between the candidate and reference methods. CONCLUSION: These results demonstrate that the candidate method is equivalent to the reference methods. HIGHLIGHT: 3M Petrifilm Rapid E. coli/Coliform Count Plate was recommended for Official First Action status for enumeration of E. coli and coliforms in a broad range of foods and environmental surfaces.


Assuntos
Escherichia coli , Microbiologia de Alimentos , Animais , Contagem de Colônia Microbiana , Meios de Cultura , Cães , Reprodutibilidade dos Testes
16.
J AOAC Int ; 103(3): 833-842, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33241359

RESUMO

BACKGROUND: CERTUS Environmental Listeria species Detection Kit (CERTUS EL Detection Kit) is a real-time, bio-contained assay designed to accurately detect Listeria species (L. grayi, L. innocua, L. ivanovii, L. marthii, L. monocytogenes, L. seeligeri, and L. welshimeri) from environmental surface matrixes using an antibody-coupled magnetic microparticle with a Surface Enhanced Raman Spectroscopy (SERS) nanoparticle technology test system paired with proprietary CERTUS EL Selective Growth Media and CERTUS Detection Unit. OBJECTIVE: The method was evaluated for AOAC®Performance Tested MethodSM certification. METHODS: Inclusivity and exclusivity, matrix studies, product consistency and stability were conducted to evaluate the CERTUS EL Detection Kit. RESULTS: In the matrix studies, stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces (4 × 4" test areas) were tested. No statistically significant differences were found by Probability of Detection analysis (POD) in any of the matrixes when results were compared to the U.S. Food and Drug Administration cultural microbiology reference method for Listeria. The CERTUS EL Detection Kit correctly identified all 50 target Listeria isolates and correctly excluded all 30 non-target strains that were analyzed. Probability of Detection analysis of CERTUS EL Detection Kit robustness, product consistency (lot-to-lot) and stability studies demonstrated no statistically significant differences, and no variation was observed between instruments. CONCLUSIONS: The data collected in these studies demonstrate that the CERTUS EL Detection Kit is a reliable method for the rapid and specific detection of Listeria from stainless steel, ceramic tile, plastic (polystyrene) and sealed concrete environmental surfaces.


Assuntos
Listeria , Técnicas Bacteriológicas , Microbiologia Ambiental , Microbiologia de Alimentos , Plásticos , Aço Inoxidável
17.
J AOAC Int ; 103(5): 1268-1276, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33241400

RESUMO

Testing milk for antibiotics before acceptance into dairies is required by the U.S. Pasteurized Milk Ordinance. Technological advances in tests have reduced screening times and improved detection accuracy. This work describes the validation of the Charm Rapid One Step Assay Beta-Lactam 30 Second Test according to the U.S. Food and Drug Administration Center for Veterinary Medicine protocol for raw commingled milk. Milk is added to the lateral flow test strip in an incubator/reader to deliver a 30 second result. Independent laboratory validation followed sensitivity, interference, and incurred residue protocols. Sensitivity, in parts per billion (ppb = µg/kg), using a probit curve determined 90% percent detection with 95% confidence, which met National Conference of Interstate Milk Shipments (NCIMS) specifications. Six U.S. approved beta-lactam drugs were detected below, but within 50% of, target/tolerance levels for penicillin G 2.9 ppb, ampicillin 5.9 ppb, amoxicillin 5.8 ppb, cephapirin 13 ppb, cloxacillin 8.1 ppb, and ceftiofur metabolites 73 ppb. No interferences were observed from 33 animal drugs at 100 ppb, somatic cells at 1.2 million/mL, or bacterial levels of >300 000 CFU/mL. Incurred residue detection levels were similar to levels determined with the spiked parent compound. The data support NCIMS that the BL30SEC method met U.S. criteria for testing milk for beta-lactams.


Assuntos
Cefapirina , Resíduos de Drogas , Ampicilina/análise , Animais , Antibacterianos/análise , Bovinos , Cefapirina/análise , Resíduos de Drogas/análise , Feminino , Leite/química , Penicilina G/análise , beta-Lactamas/análise
18.
J AOAC Int ; 92(1): 165-74, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19382575

RESUMO

The automated system for enumeration of total viable count (TVC) in foods, TEMPO TVC, uses a dehydrated culture medium and an enumeration card containing 48 wells across 3 different dilutions for the automatic determination of the most probable number (MPN). The alternative method was compared in a multilaboratory collaborative study to AOAC Method 966.23 for determination of aerobic plate count for nondairy products and the Standard Methods for the Examination of Dairy Products (SMEDP) Standard Plate Count for dairy products. Five food types, raw ground beef, raw ground chicken, cooked whitefish fillets, bagged lettuce, and milk, were analyzed for TVC by 14 collaborating laboratories throughout the United States and Canada. Three lots of naturally contaminated food products representing a wide range of counts were tested for each of the 5 food types. The study demonstrated that the overall repeatability, reproducibility, and mean log counts of the TEMPO TVC method were statistically comparable to those of the 2 standard methods at the 5% level.


Assuntos
Bactérias Aeróbias/isolamento & purificação , Contagem de Colônia Microbiana/métodos , Microbiologia de Alimentos , Carne/análise , Animais , Automação , Bovinos , Galinhas , Peixes , Indicadores e Reagentes , Laboratórios/normas , Lactuca/química , Leite/química , Leite/normas , Reprodutibilidade dos Testes
19.
J AOAC Int ; 102(5): 1455-1471, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33216925

RESUMO

BACKGROUND: The Polyskope 1.0 Multiplex Assay is a novel test to simultaneously detect Escherichia coli O157, non-O157 Shiga Toxin-Producing E. coli (STEC), Listeria monocytogenes, and Salmonella species in a single enrichment using real-time PCR. OBJECTIVE: A Performance Tested MethodSM study was conducted to validate Polyskope 1.0 for inclusivity and exclusivity as well as a matrix comparison study. METHOD: This assay was evaluated in an unpaired independent validation study compared with reference methods according to AOAC INTERNATIONAL validation guidelines. Polyskope 1.0 evaluated raw ground beef (25 g), deli turkey (25 g), baby spinach (25 g), and stainless-steel environmental surface sponges (4 × 4 in. test area) after inoculation with a suspension of the three target microorganisms. All matrices were compared with appropriate reference methods from the U.S. Food and Drug Administration Bacteriological Analytical Manual, U.S. Department of Agriculture Food Safety and Inspection Service Microbiology Laboratory Guidebook, or International Organization for Standardization standards. RESULTS: Polyskope 1.0 demonstrated no statistically significant differences between candidate and reference method results or between presumptive and confirmed results for three food matrices and one environmental surface. Results from inclusivity and exclusivity evaluations indicated the test method can accurately detect the target analytes and excluded all nontarget organisms. No differences were observed with the stability or lot-to-lot evaluations. Polyskope 1.0 demonstrated robustness by remaining unaffected by small variations in method parameters, which had no statistically significant effect on the results for all eight variations. Conclusions and Highlights: Polyskope 1.0 was shown to be a specific, highly accurate, and robust method for the detection of Listeria monocytogenes, Salmonella species, non-O157 STECs, and E. coli O157 across four matrices.


Assuntos
Escherichia coli O157/isolamento & purificação , Listeria monocytogenes/isolamento & purificação , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Salmonella/isolamento & purificação , Escherichia coli Shiga Toxigênica/isolamento & purificação , Animais , Bovinos , Microbiologia de Alimentos , Aves Domésticas/microbiologia , Carne Vermelha/microbiologia , Reprodutibilidade dos Testes , Spinacia oleracea/microbiologia , Aço Inoxidável , Turquia
20.
J AOAC Int ; 102(4): 1138-1144, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-30651164

RESUMO

Background: The MC-Media Pad™ Yeast and Mold (YM) is a ready-to use culture device that combines a test pad coated with medium and water-absorption polymers that is designed for the rapid quantification of yeast and mold in food products. Objective: The MC-Media Pad YM was compared with the U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) for the enumeration of yeast and mold in frozen orange juice concentrate. Methods: The candidate method was evaluated using a paired study design in a multilaboratory collaborative study following the current AOAC Validation Guidelines. Three target contamination levels (low, 10-100 CFU/g; medium, 100-1000 CFU/g; and high 1000-10 000 CFU/g) and an uninoculated control level (0 CFU/g) were evaluated. MC-Media Pad YM devices were enumerated after 48 and 72 h of incubation. Results: Plate count obtained by both methods were log-transformed and the difference of means (including 95% confidence intervals), repeatability SD, and SD were determined for each contamination level. Conclusions: No statistical difference was observed between the MC-Media Pad YM (for both 48 and 72 h) and the FDA BAM for each contamination level. Highlights: The new method offers a convenient alternative to the reference method (FDA BAM) for detection of yeast and mold contamination in food products, yielding reliable and comparable results in 48 h compared to 5 days for the reference method.


Assuntos
Aspergillus fumigatus/isolamento & purificação , Contagem de Colônia Microbiana/métodos , Contaminação de Alimentos/análise , Microbiologia de Alimentos/métodos , Sucos de Frutas e Vegetais/microbiologia , Leveduras/isolamento & purificação , Citrus sinensis/microbiologia