Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
J Interv Cardiol ; 2023: 6617035, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38149109

RESUMO

Background: Despite an association between operator volumes and procedural success, there remains an incomplete understanding of the contemporary utilization and procedural volumes for mitral valve transcatheter edge-to-edge repair (MTEER). We aimed to identify annual operator procedural volumes, temporal trends, and geographic variability for MTEER among Medicare patients in the United States (US). Methods: We queried the National Medicare Provider Utilization and Payment Database for a CPT code (33418) specific for MitraClip device from 2015 through 2019. We analyzed annual operator procedural volumes and incidence and identified longitudinal and geographic trends in MTEER utilization. Results: From 2015 through 2019, a total of 27,034 MTEER procedures were performed among Medicare patients in the US. The nationwide incidence increased from 6.2 per 100,000 patients in 2015 to 23.8 per 100,000 patients in 2019, a 283% increase over the study period (Ptrend < 0.001). The incidence of MTEER by state varied by nearly 900% (range 5.5 to 54.9 per 100,000 person-years). In 2019, the mean annual MTEER operator annual volume was 9.1 MTEER procedures and had grown from 6.2 per year in 2015. Conclusions: In this nationwide study of Medicare beneficiaries in the United States, we identified a significant and sustained increase in the utilization of MTEER devices and operators and growth in annual procedural volumes from 2015 through 2019 with considerable variability in utilization by state. Further studies are needed to understand the clinical impact of variability in utilization and the optimal procedural volumes to ensure high efficacy outcomes and maintain critical access to MTEER therapies.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Idoso , Humanos , Estados Unidos/epidemiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Medicare , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco
3.
Catheter Cardiovasc Interv ; 99(4): 1181-1185, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35188321

RESUMO

OBJECTIVES: To evaluate transcatheter aortic valve replacement (TAVR) operator procedural volumes, and describe temporal and geographic trends. BACKGROUND: TAVR is the standard of care for most patients with severe symptomatic aortic stenosis. Despite an association between operator procedural volume and outcomes, nationwide TAVR operator volumes have been incompletely described. METHODS: We queried the National Medicare Provider Utilization and Payment Database for transfemoral TAVRs from 2014 to 2018. Annual operator volume, state and regional volumes, and longitudinal trends were extracted and analyzed using descriptive statistics. RESULTS: In 2018, the mean annual operator volume was 23.6 TAVRs. The highest 1% of operators by volume performed 7.6% of total TAVR procedures in the United States, while 35.7% of operators performed 10 or fewer TAVRs per year. From 2014 to 2018, there was a 53.9% annualized increase in TAVRs, and the mean annual volume per operator grew from 12.5 to 23.6. There was more than five-fold variability in the density of operators (range 0.35-1.79 operators per 100,000 population) and mean operator volume by state (range 14.2-52.4 TAVRs per operator). CONCLUSIONS: In this nationally representative study of operators performing transfemoral TAVRs among Medicare patients, we found the mean annual volume of TAVR in 2018 to be 23.6 and has increased since 2014. There was considerable variability in operator density and procedural volumes, with a significant proportion of operators performing 10 or fewer TAVRs per year. Ambiguity remains in regard to the optimal balance of procedural requirements to sustain high efficacy outcomes and ensure critical access to TAVR therapies.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bases de Dados Factuais , Humanos , Medicare , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estados Unidos
4.
Catheter Cardiovasc Interv ; 100(4): 530-534, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36073664

RESUMO

BACKGROUND: There is a paucity of data on cardiogenic shock (CS) incidence and outcomes among patients with spontaneous coronary artery dissection (SCAD). METHODS: Women admitted to the hospital for acute myocardial infarction (AMI) with and without SCAD were identified from the United States National Readmission Database from October 1, 2015 to December 31, 2018. We calculated the incidence of CS among women with AMI with and without SCAD and odds for developing CS after adjusting for baseline characteristics. In addition, we report the utilization of percutaneous coronary intervention, mechanical circulatory support, severe disability surrogates, and 30-day readmission rates. RESULTS: A total of 664,292 patients admitted for AMI were eligible for analysis, including 6643 patients with SCAD and 657,649 without SCAD. Patients with SCAD were younger (57 years [interquartile range, IQR 48-68] vs. 71 years [IQR 60-81], p < 0.01) and had fewer comorbidities yet had a higher incidence of CS as compared to patients without SCAD (9% vs. 5%, p < 0.01) and remained at elevated risk after adjusting for baseline comorbidities (adjusted odds ratio 1.5 [95% confidence interval, CI 1.2-1.7]). Among patients who developed CS, those with SCAD had lower in-hospital mortality than non-SCAD (31% vs. 39%, p < 0.01), and were more likely to receive mechanical circulatory support. CONCLUSIONS: In a nationally representative sample of women admitted for AMI, we found that patients with SCAD had a higher risk of developing CS and required more frequent use of mechanical circulatory support but were more likely to survive to discharge than women suffering AMI from causes other than SCAD.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Anomalias dos Vasos Coronários , Vasos Coronários , Feminino , Humanos , Incidência , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/epidemiologia , Choque Cardiogênico/terapia , Resultado do Tratamento , Estados Unidos/epidemiologia , Doenças Vasculares/congênito
5.
Catheter Cardiovasc Interv ; 97(3): E411-E417, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32633055

RESUMO

BACKGROUND: Hypoattenuating leaflet thickening (HALT), the radiographic manifestation of transcatheter heart valve thrombosis, is commonly identified following transcatheter aortic valve replacement (TAVR) and associated with increased risk of stroke and structural valve deterioration. While anticoagulation effectively resolves HALT, routine use remains controversial. We aimed to identify hemodynamic, anatomic, and comorbid predictors of HALT. METHODS: We evaluated consecutive patients with severe aortic stenosis who underwent TAVR with Edwards SAPIEN 3 bioprosthesis at a single center between June 1, 2018 and October 30, 2019. Patients on anticoagulation and those receiving valve-in-valve were excluded. Clinically driven computed tomography (CT) imaging was performed to assess for HALT at the discretion of the treating valve team. RESULTS: A total of 78 patients with a mean age of 78 ± 10 years and STS risk score 5.5 ± 3.3% were analyzed. HALT was identified in 11 (14.1%) patients. Compared to controls, those with HALT had smaller annular areas, 435 ± 57 mm2 vs. 489 ± 79 mm2 (p = .032), but received comparable size valves. In multivariate regression, valve oversizing by more than 20% was associated with increased risk of HALT, OR 23.5, 95% CI 2.5-223, (p = .006). After initiation of anticoagulation, patients with HALT had similar rates of stroke, major bleeding, and all-cause mortality out to an average of 243 days. CONCLUSIONS: In this pragmatic study of patients undergoing TAVR with SAPIEN 3 valves, we report the novel finding that oversizing by more than 20% was independently associated with increased risk of HALT. These findings warrant confirmation in larger and prospective trials.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Estudos Prospectivos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 96(6): 1240-1248, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32091668

RESUMO

OBJECTIVES: We sought to evaluate the efficacy and safety of bivalirudin versus heparin in patients with coronary artery disease undergoing transradial artery coronary intervention (TRI). BACKGROUND: Bivalirudin and radial artery access are independently associated with improved cardiovascular outcomes. However, data supporting a strategy of combining both to achieve additive improvements in cardiovascular outcomes provide conflicting results. METHODS: A systematic search was performed to identify randomized controlled trials (RCTs) of bivalirudin, in which vascular access sites were reported. The primary outcome was net adverse clinical events (NACE) at 30 days. Secondary outcomes were long-term NACE, short-, and long-term major adverse cardiovascular events, all-cause mortality, myocardial infarction, unplanned revascularization, stent thrombosis, and major bleeding. RESULTS: We identified 10 RCTs, including 16,328 patients who underwent TRI (mean age 64.6 ± 15.7 years, 72.5% male). Bivalirudin use was associated with decreased 30-day NACE compared with heparin (6.3 vs. 7.4%; risk ratio [RR] = 0.87; 95% confidence interval [CI] = 0.76-0.99; p = .04; number needed to treat = 91). No significant interactions were observed based on clinical presentation, administration of P2Y12 inhibitors, or glycoprotein IIb/IIIa-receptor inhibitors (GPI) use. There were no significant differences between groups in any prespecified secondary outcomes. There was, however, a significant reduction of major bleeding in the bivalirudin group compared with heparin when used in combination with routine GPI (RR = 0.41; 95% CI = 0.19-0.90; p = .03). CONCLUSIONS: Among patients undergoing TRI, use of bivalirudin was associated with significantly reduced 30-day NACE compared with heparin. There was no significant difference in long term NACE, ischemic, or bleeding events compared with heparin.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Cateterismo Periférico , Doença da Artéria Coronariana/terapia , Heparina/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Artéria Radial , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/mortalidade , Trombose Coronária/prevenção & controle , Feminino , Hemorragia/induzido quimicamente , Hemorragia/mortalidade , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Fragmentos de Peptídeos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Punções , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
J Thromb Thrombolysis ; 50(4): 867-873, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32607653

RESUMO

Among patients who have undergone percutaneous coronary intervention (PCI), the use of dual antiplatelet therapy (DAPT) is associated with increased risk of bleeding, but decreased stent thrombosis and myocardial infarction unrelated to the stent. As PCI techniques and devices have progressed, the optimal duration of DAPT has come into question. We identified all randomized controlled trials (RCTs) of patients undergoing PCI, who received one or more drug eluting stents (DES) for stable coronary artery disease (CAD) or acute coronary syndrome (ACS), and randomized to short (1-3 months) versus standard duration DAPT. The prespecified primary outcome was major adverse cardiovascular events (MACE). Important secondary outcomes were net adverse clinical events (NACE) defined as MACE and major bleeding; any bleeding; major bleeding; all-cause death; cardiovascular death. We calculated hazard ratios (HR) and 95% confidence intervals (CI) using random-effects model. Analysis included 7 RCTs, comprising 35,857 patients and 53,321 patient-years of follow-up. The mean (SD) age of patients was 64.4 (10.6) years, 49.6% of patients presented with ACS, and 25.5% were female. There was no difference between short and standard-length DAPT in regards to MACE (HR = 0.93; 95% CI 0.84-1.03; p = 0.19), NACE (HR = 0.93; 95% CI 0.85-1.02; p = 0.12), all-cause death (HR = 0.92; 95% CI 0.80-1.05; p = 0.21), or cardiovascular death (HR = 0.85; 95% CI 0.64-1.13; p = 0.26). However, short-term DAPT was associated with significantly reduced major bleeding events (HR = 0.67; 95% CI 0.47-0.95; p = 0.03) and any bleeding event (HR = 0.63; 95% CI 0.44-0.90; p = 0.01) compared with standard-length DAPT. Among patients undergoing PCI for CAD, the use of short-term DAPT (1-3 months) followed by single antiplatelet therapy was associated with a lower incidence of clinically relevant bleeding events, but with similar risk of MACE, all-cause death, and cardiovascular death compared with standard duration DAPT.


Assuntos
Doença da Artéria Coronariana/cirurgia , Reestenose Coronária/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Quimioterapia Combinada/métodos , Duração da Terapia , Humanos , Intervenção Coronária Percutânea/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
8.
PLoS Med ; 16(4): e1002797, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31034476

RESUMO

BACKGROUND: The efficacy, safety, and clinical importance of extended-duration thromboprophylaxis (EDT) for prevention of venous thromboembolism (VTE) in medical patients remain unclear. We compared the efficacy and safety of EDT in patients hospitalized for medical illness. METHODS AND FINDINGS: Electronic databases of PubMed/MEDLINE, EMBASE, Cochrane Central, and ClinicalTrials.gov were searched from inception to March 21, 2019. We included randomized clinical trials (RCTs) reporting use of EDT for prevention of VTE. We performed trial sequential and cumulative meta-analyses to evaluate EDT effects on the primary efficacy endpoint of symptomatic VTE or VTE-related death, International Society on Thrombosis and Haemostasis (ISTH) major or fatal bleeding, and all-cause mortality. The pooled number needed to treat (NNT) to prevent one symptomatic or fatal VTE event and the number needed to harm (NNH) to cause one major or fatal bleeding event were calculated. Across 5 RCTs with 40,247 patients (mean age: 67-77 years, proportion of women: 48%-54%, most common reason for admission: heart failure), the duration of EDT ranged from 24-47 days. EDT reduced symptomatic VTE or VTE-related death compared with standard of care (0.8% versus 1.2%; risk ratio [RR]: 0.61, 95% confidence interval [CI]: 0.44-0.83; p = 0.002). EDT increased risk of ISTH major or fatal bleeding (0.6% versus 0.3%; RR: 2.04, 95% CI: 1.42-2.91; p < 0.001) in both meta-analyses and trial sequential analyses. Pooled NNT to prevent one symptomatic VTE or VTE-related death was 250 (95% CI: 167-500), whereas NNH to cause one major or fatal bleeding event was 333 (95% CI: 200-1,000). Limitations of the study include variation in enrollment criteria, individual therapies, duration of EDT, and VTE detection protocols across included trials. CONCLUSIONS: In this systematic review and meta-analysis of 5 randomized trials, we observed that use of a post-hospital discharge EDT strategy for a 4-to-6-week period reduced symptomatic or fatal VTE events at the expense of increased risk of major or fatal bleeding. Further investigations are still required to define the risks and benefits in discrete medically ill cohorts, evaluate cost-effectiveness, and develop pathways for targeted implementation of this postdischarge EDT strategy. TRIAL REGISTRATION: PROSPERO CRD42018109151.


Assuntos
Anticoagulantes/administração & dosagem , Quimioprevenção/métodos , Hospitalização , Tromboembolia Venosa/prevenção & controle , Idoso , Anticoagulantes/efeitos adversos , Quimioprevenção/efeitos adversos , Quimioprevenção/estatística & dados numéricos , Estudos de Coortes , Esquema de Medicação , Feminino , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Ensaios Clínicos Controlados Aleatórios como Assunto/estatística & dados numéricos , Tromboembolia Venosa/epidemiologia
9.
Eur Heart J ; 39(19): 1726-1735a, 2018 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-29668889

RESUMO

Aims: Of patients with atrial fibrillation (AF), approximately 10% undergo percutaneous coronary intervention (PCI). We studied the safety and efficacy of dual vs. triple antithrombotic therapy (DAT vs. TAT) in this population. Methods and results: A systematic review and meta-analysis was conducted using PubMed, Embase, EBSCO, Cochrane database of systematic reviews, Web of Science, and relevant meeting abstracts for Phase 3, randomized trials that compared DAT vs. TAT in patients with AF following PCI. Four trials including 5317 patients were included, of whom 3039 (57%) received DAT. Compared with the TAT arm, Thrombolysis in Myocardial Infarction (TIMI) major or minor bleeding showed a reduction by 47% in the DAT arm [4.3% vs. 9.0%; hazard ratio (HR) 0.53, 95% credible interval (CrI) 0.36-0.85, I2 = 42.9%]. In addition, there was no difference in the trial-defined major adverse cardiac events (MACE) (10.4% vs. 10.0%, HR 0.85, 95% CrI 0.48-1.29, I2 = 58.4%), or in individual outcomes of all-cause mortality, cardiac death, myocardial infarction, stent thrombosis, or stroke between the two arms. Conclusion: Compared with TAT, DAT shows a reduction in TIMI major or minor bleeding by 47% with comparable outcomes of MACE. Our findings support the concept that DAT may be a better option than TAT in many patients with AF following PCI.


Assuntos
Fibrilação Atrial/complicações , Fibrinolíticos/efeitos adversos , Fibrinolíticos/uso terapêutico , Intervenção Coronária Percutânea , Tromboembolia/prevenção & controle , Ensaios Clínicos Fase III como Assunto , Quimioterapia Combinada , Fibrinolíticos/administração & dosagem , Hemorragia/induzido quimicamente , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
Catheter Cardiovasc Interv ; 92(5): 860-861, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30450711

RESUMO

Marked heterogeneity exists regarding the dose, time and route of administration of unfractionated heparin for diagnostic trans-radial procedures. In an era of smaller caliber hydrophilic radial sheaths, patent hemostasis technique, and shorter compression times, the utility of heparin to prevent radial artery occlusion remains a question. A randomized clinical trial assessing the utility, timing, dose, and route of administration of unfractionated heparin for diagnostic radial catheterization with an aim to prevent radial artery occlusion is needed.


Assuntos
Arteriopatias Oclusivas , Artéria Radial , Cateterismo Cardíaco , Técnicas Hemostáticas , Heparina , Humanos , Inquéritos e Questionários
11.
Eur Heart J ; 38(41): 3082-3089, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29020244

RESUMO

AIMS: Total occlusion (TO) of the culprit artery usually presents with ST-elevation myocardial infarction. A subset of patients with TO present as non-ST segment elevation myocardial infarction (NSTEMI) without classic ST-elevation on the electrocardiogram. This may lead to delay in identification of these patients and further management. We performed a meta-analysis to estimate the difference in outcomes between totally occluded and non-occluded culprit arteries in patients with NSTEMI. METHODS AND RESULTS: Our literature search yielded seven studies with 40 777 patients. The outcomes assessed were clinical presentation (Killip class), left ventricular ejection fraction, time to angiography, major cardiac adverse events (MACE) and all-cause mortality. The generic inverse or Mantel-Haenszel method was used to pool relevant outcomes and the mean difference (MD) or relative risk (RR) was calculated. A total of 10 415 (25.5%) patients had an occluded culprit artery with a predominant infero-lateral distribution (40% right coronary and 33% left circumflex artery). There was an increased risk of both MACE (short-term RR: 1.41; CI: 1.17, 1.70; P = 0.0003; I2 = 26%; medium- to long-term RR: 1.32; CI: 1.11, 1.56; P = 0.001; I2 = 25%) and all-cause mortality (short-term RR: 1.67; CI: 1.31, 2.13; P < 0.0001; I2 = 41%; medium to long-term RR: 1.42; CI: 1.08, 1.86; P = 0.01; I2 = 32%) with TO of the culprit artery. CONCLUSION: Our meta-analysis suggests that patients with NSTEMI who demonstrate a totally occluded culprit vessel on coronary angiography are at higher risk of mortality and major adverse cardiac events. Better risk stratification tools are needed to identify such high-risk acute coronary syndrome patients to facilitate earlier revascularization and potentially to improve outcomes.


Assuntos
Oclusão Coronária/complicações , Infarto do Miocárdio sem Supradesnível do Segmento ST/etiologia , Doença Aguda , Causas de Morte , Angiografia Coronária/estatística & dados numéricos , Oclusão Coronária/mortalidade , Oclusão Coronária/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Intervenção Coronária Percutânea/mortalidade , Intervenção Coronária Percutânea/estatística & dados numéricos , Fatores de Risco , Tempo para o Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade
12.
Am Heart J ; 174: 29-36, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26995367

RESUMO

BACKGROUND: Significant racial/ethnic differences exist in the incidence of atrial fibrillation (AF). However, less is known about racial/ethnic differences in quality of life (QoL), treatment, and outcomes associated with AF. METHODS: Using data from the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation, we compared clinical characteristics, QoL, management strategies, and long-term outcomes associated with AF among various racial/ethnic groups. RESULTS: We analyzed 9,542 participants with AF (mean age 74 ± 11 years, 43% women, 91% white, 5% black, 4% Hispanic) from 174 centers. Compared with AF patients identified as white race, patients identified as Hispanic ethnicity and those identified as black race were younger, were more often women, and had more cardiac and noncardiac comorbidities. Black patients were more symptomatic with worse QoL and were less likely to be treated with a rhythm control strategy than other racial/ethnic groups. There were no significant racial/ethnic differences in CHA2DS2-VASc stroke or ATRIA bleeding risk scores and rates of oral anticoagulation use were similar. However, racial and ethnic minority populations treated with warfarin spent a lower median time in therapeutic range of international normalized ratio (59% blacks vs 68% whites vs 62% Hispanics, P < .0001). There was no difference in long-term outcomes associated with AF between the 3 groups at a median follow-up of 2.1 years. CONCLUSION: Relative to white and Hispanic patients, black patients with AF had more symptoms, were less likely to receive rhythm control interventions, and had lower quality of warfarin management. Despite these differences, clinical events at 2 years were similar by race and ethnicity.


Assuntos
Fibrilação Atrial/etnologia , Terapia de Ressincronização Cardíaca/métodos , Gerenciamento Clínico , Etnicidade , Qualidade de Vida , Grupos Raciais , Sistema de Registros , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Embolia/etnologia , Embolia/etiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Prognóstico , Acidente Vascular Cerebral/etnologia , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida/tendências , Fatores de Tempo , Estados Unidos/epidemiologia
14.
Interv Cardiol Clin ; 13(2): 155-165, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432759

RESUMO

Degenerative mitral regurgitation (DMR) has earned great interest because of modern and innovative technologies emerging in its treatment. MR affects roughly one-tenth of those older adults over the age of 75. MR if untreated leads to adverse heart remodeling, resulting in left ventricular dysfunction, pulmonary hypertension, and heart failure syndrome. Despite surgical valve repair/replacement treatment being the standard of care, a significant proportion of severe MR patients face unmet clinical needs because of high or prohibitive surgical risks. This has led to the emergence of transcatheter therapies for high- and prohibitive-risk surgical patients, most notably mitral transcatheter edge-to-edge repair devices.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Humanos , Idoso , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/cirurgia , Tecnologia
15.
Interv Cardiol Clin ; 13(2): 167-182, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38432760

RESUMO

Functional mitral regurgitation appears commonly among all heart failure phenotypes and can affect symptom burden and degree of maladaptive remodeling. Transcatheter mitral valve edge-to-edge repair therapies recently became an important part of the routine heart failure armamentarium for carefully selected and medically optimized candidates. Patient selection is considering heart failure staging, relevant comorbidities, as well as anatomic criteria. Indications and device platforms are currently expanding.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Seleção de Pacientes , Insuficiência Cardíaca/cirurgia , Carga de Sintomas
16.
J Clin Med ; 13(12)2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38929915

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as an alternative treatment option for patients with severe aortic stenosis regardless of surgical risk, particularly in those with a high and prohibitive risk. Since the advent of TAVR, transfemoral access has been the standard of care. However, given comorbidities and anatomical limitations, a proportion of patients are not good candidates for a transfemoral approach. Alternative access, including transapical, transaortic, transaxillary, transsubclavian, transcarotid, and transcaval, can be considered. Each alternative access has advantages and disadvantages, so the vascular route should be tailored to the patient's characteristics. However, there is no standardized algorithm when choosing the optimal alternative vascular access. In this review, we analyzed the evolution and current evidence for the most common alternative access for TAVR and proposed an algorithm for choosing the optimal vascular access in this patient population.

19.
Am J Ther ; 20(6): e720-2, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-21768871

RESUMO

Sertraline is a selective serotonin reuptake inhibitor, which is a commonly used drug for major depressive disorder. Most frequently reported adverse effects of sertraline in patients receiving 50-150 mg/d are dry mouth, headache, diarrhea, nausea, vomiting, sweating, and dizziness. We hereby report one of the few cases of sertraline-induced ventricular tachycardia, which has been for the first time objectively assessed by the Naranjo scale. We therefore urge the primary care physicians and the cardiologists to keep sertraline as a possible precipitating factor for evaluation of ventricular tachycardia.


Assuntos
Inibidores Seletivos de Recaptação de Serotonina/efeitos adversos , Sertralina/efeitos adversos , Taquicardia Ventricular/induzido quimicamente , Transtorno Depressivo Maior/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores Seletivos de Recaptação de Serotonina/uso terapêutico , Sertralina/uso terapêutico
20.
J Invasive Cardiol ; 35(6): E291-E293, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37410745

RESUMO

Chest radiation therapy (XRT) has been associated with a higher rate of mortality following surgical aortic valve replacement. We performed a single-center retrospective analysis of patients with severe AS who underwent TAVI from January 1 2012 to July 31 2020 comparing patients with and without XRT. A total of 915 patients met inclusion criteria, with a total of 50 patients found to have a history of XRT. At a mean follow-up of 2.4 years, unadjusted and propensity score matching analysis demonstrated no differences in mortality, heart failure or bleeding-related hospitalization, overall stroke, and 30-day pacemaker implantation in patients with and without XRT.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Pontuação de Propensão , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA