1.
Prenat Diagn ; 43(8): 1002-1007, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37160691

RESUMO

OBJECTIVE: To evaluate fetal brain development using MRI (magnetic resonance imaging) in CDH (congenital diaphragmatic hernia). METHODS: 52 isolated left CDH and 104 control fetuses were imaged using MRI. Brain morphometry (Biparietal diameter-BPD, brain fronto-occipital diameter-BFOD, third ventricle, posterior ventricles, transcerebellar diameter-TCD, anteroposterior and craniocaudal cerebellar vermis diameter-AP and CC) and cortical structures (bilateral cingulate fissure-CF, insular fissure-IF, insular depth - ID) were compared with controls using Mann-Whitney test. RESULTS: Median gestational age at MRI (p = 0.95)and the median biparietal diameter (p = 0.737) were comparable. Among morphometric parameters, only the brain fronto-occipital diameter was significantly smaller in CDH (p = 0.001) and the third ventricle was significantly greater in CDH (<0.0001). Among cortical structures, the cingulate and insular fissures were significantly deeper in CDH fetuses (p < 0.0001) as the insular depth ID was smaller in CDH (p < 0.03). CONCLUSIONS: CDH fetuses have a smaller fronto-occipital diameter, reduced insular depth, deeper cingulate and insular fissure, and greater third ventricle width as compared to controls. These findings suggest that left CDH may have an impact on fetal brain development with an overall reduction in brain volume.


Assuntos
Hérnias Diafragmáticas Congênitas , Gravidez , Feminino , Humanos , Hérnias Diafragmáticas Congênitas/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Feto/diagnóstico por imagem , Idade Gestacional , Encéfalo , Imageamento por Ressonância Magnética/métodos , Pulmão/diagnóstico por imagem
2.
Medicina (Kaunas) ; 58(4)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35454364

RESUMO

Urinary incontinence (UI) is a very common condition, negatively affecting social, occupational, domestic, and psychophysical wellbeing. In particular, a peculiar and detrimental effect of UI has been described concerning sexual function. However, the impact of UI on quality of life is not fully understood yet, and further investigation into this issue is warranted. With this narrative review, we aimed to report the current evidence from recent literature regarding the quality of life and psychological wellbeing in patients with urinary incontinence, with a special focus on sexual function and its evolution after UI treatment. There is strong evidence that urinary incontinence-in its different forms, including stress urinary incontinence, urge urinary incontinence, mixed urinary incontinence, and coital urinary incontinence-negatively affects female sexual function. Treatments aimed to cure urinary incontinence-including pelvic floor muscles training, medications, and surgery-seem to improve quality of life by recovering, at least in part, sexual function. In conclusion, there is a substantial association between involuntary urinary loss and sex life quality. However, few studies are available and more evidence is needed before consistent conclusions can be made.


Assuntos
Incontinência Urinária por Estresse , Incontinência Urinária , Feminino , Humanos , Masculino , Qualidade de Vida/psicologia , Sexualidade/psicologia , Incontinência Urinária/complicações , Incontinência Urinária/psicologia
3.
Medicina (Kaunas) ; 58(4)2022 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-35454390

RESUMO

Background and Objectives: Since the Food and Drug Administration's (FDA) approval in 2005, the application of robotic surgery (RS) in gynecology has been adopted all over the world. This study aimed to provide an update on RS in benign gynecological pathology by reporting the scientific recommendations and high-value scientific literature available to date. Materials and Methods: A systematic review of the literature was performed. Prospective randomized clinical trials (RCT) and large retrospective trials were included in the present review. Results: Twenty-two studies were considered eligible for the review: eight studies regarding robotic myomectomy, five studies on robotic hysterectomy, five studies about RS in endometriosis treatment, and four studies on robotic pelvic organ prolapse (POP) treatment. Overall, 12 RCT and 10 retrospective studies were included in the analysis. In total 269,728 patients were enrolled, 1721 in the myomectomy group, 265,100 in the hysterectomy group, 1527 in the endometriosis surgical treatment group, and 1380 patients received treatment for POP. Conclusions: Currently, a minimally invasive approach is suggested in benign gynecological pathologies. According to the available evidence, RS has comparable clinical outcomes compared to laparoscopy (LPS). RS allowed a growing number of patients to gain access to MIS and benefit from a minimally invasive treatment, due to a flattened learning curve and enhanced dexterity and visualization.


Assuntos
Endometriose , Ginecologia , Laparoscopia , Procedimentos Cirúrgicos Robóticos , Endometriose/cirurgia , Feminino , Procedimentos Cirúrgicos em Ginecologia , Humanos , Histerectomia , Estados Unidos
4.
Artigo em Inglês | MEDLINE | ID: mdl-35565142

RESUMO

BACKGROUND AND OBJECTIVES: Shoulder dystocia (ShD) is one of most dangerous obstetric complication. The objective of this study was to determine if the ultrasonographic fetal biacromial diameter (BA) and derived parameters could predict ShD in uncomplicated term pregnancies. MATERIALS AND METHODS: We conducted a prospective observational study in a tertiary care university hospital from March 2021 to February 2022. We included all full-term pregnancies accepted for delivery that received an accurate ultrasonography (USG) scan before delivery. USG biometry and estimated fetal weight (EFW) were collected. Therefore, we evaluated the diameter of the mid-arm, the transverse thoracic diameter (TTD) and the biacromial diameter (BA). BA was estimated using Youssef's formula: TTD + 2 mid-arm diameters. The primary outcome was the evaluation of BA and its related parameters (BA/biparietal diameter (BPD), BA/head circumference (HC) and BA-BPD in fetuses with ShD versus fetuses without ShD. Diagnostic accuracy for ShD of BA, BA/BPD, BA/HC and BA-BPD was evaluated using receiver operator curve (ROC) analysis. RESULTS: 90 women were included in the analysis, four of these had ShD and required extra maneuvers after head delivery. BA was increased in fetuses with ShD (150.4 cm; 95% CI 133.2 cm to 167.6 cm) compared to no-ShD (133.5 cm; 95% CI 130.1 cm to 137.0 cm; p = 0.04). Significant differences were also found between ShD and no-ShD groups for BA/BPD (1.66 (95% CI 1.46 to 1.86) vs. 1.44 (95% CI 1.41 to 1.48); p = 0.04), BA/HC (0.45 (95% CI 0.40 to 0.49) vs. 0.39 (95% CI 0.38 to 0.40); p = 0.01), BA-BPD (60.0 mm (95% CI 42.4 to 77.6 cm) vs. 41.4 (95% CI 38.2 to 44.6); p = 0.03), respectively. ROC analysis showed an overall good accuracy for ShD, with an AUC of 0.821 (p = 0.001) for BA alone and 0.881 (p = 0.001), 0.857 (p = 0.016) and 0.867 (p = 0.013) for BA/BPD, BA-BPD and BA/HC, respectively. CONCLUSIONS: BA alone, as well as BA/BPD, BA/HC and BA-BPD might be useful predictors of ShD in uncomplicated term pregnancies. However, such evidence needs extensive confirmation by means of additional studies with large sample sizes, especially in case of pregnancies at high risk for ShD (i.e., gestational diabetes).


Assuntos
Distocia do Ombro , Feminino , Peso Fetal , Feto , Idade Gestacional , Humanos , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal