Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 79
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Respir Res ; 25(1): 232, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834976

RESUMO

AIM: Acute respiratory distress syndrome or ARDS is an acute, severe form of respiratory failure characterised by poor oxygenation and bilateral pulmonary infiltrates. Advancements in signal processing and machine learning have led to promising solutions for classification, event detection and predictive models in the management of ARDS. METHOD: In this review, we provide systematic description of different studies in the application of Machine Learning (ML) and artificial intelligence for management, prediction, and classification of ARDS. We searched the following databases: Google Scholar, PubMed, and EBSCO from 2009 to 2023. A total of 243 studies was screened, in which, 52 studies were included for review and analysis. We integrated knowledge of previous work providing the state of art and overview of explainable decision models in machine learning and have identified areas for future research. RESULTS: Gradient boosting is the most common and successful method utilised in 12 (23.1%) of the studies. Due to limitation of data size available, neural network and its variation is used by only 8 (15.4%) studies. Whilst all studies used cross validating technique or separated database for validation, only 1 study validated the model with clinician input. Explainability methods were presented in 15 (28.8%) of studies with the most common method is feature importance which used 14 times. CONCLUSION: For databases of 5000 or fewer samples, extreme gradient boosting has the highest probability of success. A large, multi-region, multi centre database is required to reduce bias and take advantage of neural network method. A framework for validating with and explaining ML model to clinicians involved in the management of ARDS would be very helpful for development and deployment of the ML model.


Assuntos
Aprendizado de Máquina , Síndrome do Desconforto Respiratório , Humanos , Valor Preditivo dos Testes , Síndrome do Desconforto Respiratório/classificação , Síndrome do Desconforto Respiratório/diagnóstico , Síndrome do Desconforto Respiratório/terapia
2.
Ann Surg ; 277(1): e175-e183, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33630463

RESUMO

OBJECTIVE: We investigated the utility of geometric features for future AAA growth prediction. BACKGROUND: Novel methods for growth prediction of AAA are recognized as a research priority. Geometric feature have been used to predict cerebral aneurysm rupture, but not examined as predictor of AAA growth. METHODS: Computerized tomography (CT) scans from patients with infra-renal AAAs were analyzed. Aortic volumes were segmented using an automated pipeline to extract AAA diameter (APD), undulation index (UI), and radius of curvature (RC). Using a prospectively recruited cohort, we first examined the relation between these geometric measurements to patients' demographic features (n = 102). A separate 192 AAA patients with serial CT scans during AAA surveillance were identified from an ongoing clinical database. Multinomial logistic and multiple linear regression models were trained and optimized to predict future AAA growth in these patients. RESULTS: There was no correlation between the geometric measurements and patients' demographic features. APD (Spearman r = 0.25, P < 0.05), UI (Spearman r = 0.38, P < 0.001) and RC (Spearman r =-0.53, P < 0.001) significantly correlated with annual AAA growth. Using APD, UI, and RC as 3 input variables, the area under receiver operating characteristics curve for predicting slow growth (<2.5 mm/yr) or fast growth (>5 mm/yr) at 12 months are 0.80 and 0.79, respectively. The prediction or growth rate is within 2 mm error in 87% of cases. CONCLUSIONS: Geometric features of an AAA can predict its future growth. This method can be applied to routine clinical CT scans acquired from patients during their AAA surveillance pathway.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Humanos , Valor Preditivo dos Testes , Aneurisma da Aorta Abdominal/epidemiologia , Tomografia Computadorizada por Raios X , Curva ROC , Ruptura Aórtica/epidemiologia
3.
Ann Surg ; 277(2): e449-e459, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33913675

RESUMO

BACKGROUND: Intravenous contrast agents are routinely used in CT imaging to enable the visualization of intravascular pathology, such as with abdominal aortic aneurysms. However, the injection is contraindicated in patients with iodine allergy and is associated with renal complications. OBJECTIVES: In this study, we investigate if the raw data acquired from a noncontrast CT image contains sufficient information to differentiate blood and other soft tissue components. A deep learning pipeline underpinned by generative adversarial networks was developed to simulate contrast enhanced CTA images using noncontrast CTs. METHODS AND RESULTS: Two generative models (cycle- and conditional) are trained with paired noncontrast and contrast enhanced CTs from seventy-five patients (total of 11,243 pairs of images) with abdominal aortic aneurysms in a 3-fold cross-validation approach with a training/testing split of 50:25 patients. Subsequently, models were evaluated on an independent validation cohort of 200 patients (total of 29,468 pairs of images). Both deep learning generative models are able to perform this image transformation task with the Cycle-generative adversarial network (GAN) model outperforming the Conditional-GAN model as measured by aneurysm lumen segmentation accuracy (Cycle-GAN: 86.1% ± 12.2% vs Con-GAN: 85.7% ± 10.4%) and thrombus spatial morphology classification accuracy (Cycle-GAN: 93.5% vs Con-GAN: 85.7%). CONCLUSION: This pipeline implements deep learning methods to generate CTAs from noncontrast images, without the need of contrast injection, that bear strong concordance to the ground truth and enable the assessment ofimportant clinical metrics. Our pipeline is poised to disrupt clinical pathways requiring intravenous contrast.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma Aórtico , Aprendizado Profundo , Humanos , Meios de Contraste , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Administração Intravenosa
4.
Ann Surg ; 276(6): e1017-lpagee1027, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-33234786

RESUMO

BACKGROUND: Existing methods to reconstruct vascular structures from a computerized tomography (CT) angiogram rely on contrast injection to enhance the radio-density within the vessel lumen. However, pathological changes in the vasculature may be present that prevent accurate reconstruction. In aortic aneurysmal disease, a thrombus adherent to the aortic wall within the expanding aneurysmal sac is present in >90% of cases. These deformations prevent the automatic extraction of vital clinical information by existing image reconstruction methods. AIM: In this study, a deep learning architecture consisting of a modified U-Net with attention-gating was implemented to establish a high-throughput and automated segmentation pipeline of pathological blood vessels in CT images acquired with or without the use of a contrast agent. METHODS AND RESULTS: Seventy-Five patients with paired noncontrast and contrast-enhanced CT images were randomly selected from an ongoing study (Ethics Ref 13/SC/0250), manually annotated and used for model training and evaluation. Data augmentation was implemented to diversify the training data set in a ratio of 10:1. The performance of our Attention-based U-Net in extracting both the inner (blood flow) lumen and the wall structure of the aortic aneurysm from CT angiograms was compared against a generic 3-D U-Net and displayed superior results. Implementation of this network within the aortic segmentation pipeline for both contrast and noncontrast CT images has allowed for accurate and efficient extraction of the morphological and pathological features of the entire aortic volume. CONCLUSIONS: This extraction method can be used to standardize aneurysmal disease management and sets the foundation for complex geometric and morphological analysis. Furthermore, this pipeline can be extended to other vascular pathologies.


Assuntos
Aneurisma Aórtico , Aprendizado Profundo , Humanos , Tomografia Computadorizada por Raios X/métodos , Aorta
5.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200257, 2021 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-34689630

RESUMO

Cardiac magnetic resonance (CMR) imaging is a valuable modality in the diagnosis and characterization of cardiovascular diseases, since it can identify abnormalities in structure and function of the myocardium non-invasively and without the need for ionizing radiation. However, in clinical practice, it is commonly acquired as a collection of separated and independent 2D image planes, which limits its accuracy in 3D analysis. This paper presents a completely automated pipeline for generating patient-specific 3D biventricular heart models from cine magnetic resonance (MR) slices. Our pipeline automatically selects the relevant cine MR images, segments them using a deep learning-based method to extract the heart contours, and aligns the contours in 3D space correcting possible misalignments due to breathing or subject motion first using the intensity and contours information from the cine data and next with the help of a statistical shape model. Finally, the sparse 3D representation of the contours is used to generate a smooth 3D biventricular mesh. The computational pipeline is applied and evaluated in a CMR dataset of 20 healthy subjects. Our results show an average reduction of misalignment artefacts from 1.82 ± 1.60 mm to 0.72 ± 0.73 mm over 20 subjects, in terms of distance from the final reconstructed mesh. The high-resolution 3D biventricular meshes obtained with our computational pipeline are used for simulations of electrical activation patterns, showing agreement with non-invasive electrocardiographic imaging. The automatic methodologies presented here for patient-specific MR imaging-based 3D biventricular representations contribute to the efficient realization of precision medicine, enabling the enhanced interpretability of clinical data, the digital twin vision through patient-specific image-based modelling and simulation, and augmented reality applications. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
6.
Eur Heart J ; 41(48): 4556-4564, 2020 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-32128588

RESUMO

Providing therapies tailored to each patient is the vision of precision medicine, enabled by the increasing ability to capture extensive data about individual patients. In this position paper, we argue that the second enabling pillar towards this vision is the increasing power of computers and algorithms to learn, reason, and build the 'digital twin' of a patient. Computational models are boosting the capacity to draw diagnosis and prognosis, and future treatments will be tailored not only to current health status and data, but also to an accurate projection of the pathways to restore health by model predictions. The early steps of the digital twin in the area of cardiovascular medicine are reviewed in this article, together with a discussion of the challenges and opportunities ahead. We emphasize the synergies between mechanistic and statistical models in accelerating cardiovascular research and enabling the vision of precision medicine.


Assuntos
Inteligência Artificial , Cardiologia , Algoritmos , Humanos , Medicina de Precisão
7.
Europace ; 20(suppl_3): iii102-iii112, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30476051

RESUMO

AIMS: To identify key structural and electrophysiological features explaining distinct electrocardiogram (ECG) phenotypes in hypertrophic cardiomyopathy (HCM). METHODS AND RESULTS: Human heart-torso anatomical models were constructed from cardiac magnetic resonance (CMR) images of HCM patients, representative of ECG phenotypes identified previously. High performance computing simulations using bidomain models were conducted to dissect key features explaining the ECG phenotypes with increased HCM Risk-SCD scores, namely Group 1A, characterized by normal QRS but inverted T waves laterally and coexistence of apical and septal hypertrophy; and Group 3 with marked QRS abnormalities (deep and wide S waves laterally) and septal hypertrophy. Hypertrophic cardiomyopathy abnormalities characterized from CMR, such as hypertrophy, tissue microstructure alterations, abnormal conduction system, and ionic remodelling, were selectively included to assess their influence on ECG morphology. Electrocardiogram abnormalities could not be explained by increased wall thickness nor by local conduction abnormalities associated with fibre disarray or fibrosis. Inverted T wave with normal QRS (Group 1A) was obtained with increased apico-basal repolarization gradient caused by ionic remodelling in septum and apex. Lateral QRS abnormalities (Group 3) were only recovered with abnormal Purkinje-myocardium coupling. CONCLUSION: Two ECG-based HCM phenotypes are explained by distinct mechanisms: ionic remodelling and action potential prolongation in hypertrophied apical and septal areas lead to T wave inversion with normal QRS complexes, whereas abnormal Purkinje-myocardial coupling causes abnormal QRS morphology in V4-V6. These findings have potential implications for patients' management as they point towards different arrhythmia mechanisms in different phenotypes.


Assuntos
Potenciais de Ação , Cardiomiopatia Hipertrófica/diagnóstico , Simulação por Computador , Eletrocardiografia , Acoplamento Excitação-Contração , Frequência Cardíaca , Modelos Cardiovasculares , Contração Miocárdica , Ramos Subendocárdicos/fisiopatologia , Cardiomiopatia Hipertrófica/etiologia , Cardiomiopatia Hipertrófica/fisiopatologia , Humanos , Imageamento por Ressonância Magnética , Fenótipo , Valor Preditivo dos Testes , Remodelação Ventricular
8.
Radiology ; 282(3): 857-868, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27732160

RESUMO

Purpose To compare lobar ventilation and apparent diffusion coefficient (ADC) values obtained with hyperpolarized xenon 129 (129Xe) magnetic resonance (MR) imaging to quantitative computed tomography (CT) metrics on a lobar basis and pulmonary function test (PFT) results on a whole-lung basis in patients with chronic obstructive pulmonary disease (COPD). Materials and Methods The study was approved by the National Research Ethics Service Committee; written informed consent was obtained from all patients. Twenty-two patients with COPD (Global Initiative for Chronic Obstructive Lung Disease stage II-IV) underwent hyperpolarized 129Xe MR imaging at 1.5 T, quantitative CT, and PFTs. Whole-lung and lobar 129Xe MR imaging parameters were obtained by using automated segmentation of multisection hyperpolarized 129Xe MR ventilation images and hyperpolarized 129Xe MR diffusion-weighted images after coregistration to CT scans. Whole-lung and lobar quantitative CT-derived metrics for emphysema and bronchial wall thickness were calculated. Pearson correlation coefficients were used to evaluate the relationship between imaging measures and PFT results. Results Percentage ventilated volume and average ADC at lobar 129Xe MR imaging showed correlation with percentage emphysema at lobar quantitative CT (r = -0.32, P < .001 and r = 0.75, P < .0001, respectively). The average ADC at whole-lung 129Xe MR imaging showed moderate correlation with PFT results (percentage predicted transfer factor of the lung for carbon monoxide [Tlco]: r = -0.61, P < .005) and percentage predicted functional residual capacity (r = 0.47, P < .05). Whole-lung quantitative CT percentage emphysema also showed statistically significant correlation with percentage predicted Tlco (r = -0.65, P < .005). Conclusion Lobar ventilation and ADC values obtained from hyperpolarized 129Xe MR imaging demonstrated correlation with quantitative CT percentage emphysema on a lobar basis and with PFT results on a whole-lung basis. © RSNA, 2016.


Assuntos
Imageamento por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Isótopos de Xenônio , Idoso , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doença Pulmonar Obstrutiva Crônica/patologia , Reprodutibilidade dos Testes
9.
Magn Reson Med ; 78(3): 1174-1186, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27670633

RESUMO

PURPOSE: The diffusion tensor model assumes Gaussian diffusion and is widely applied in cardiac diffusion MRI. However, diffusion in biological tissue deviates from a Gaussian profile as a result of hindrance and restriction from cell and tissue microstructure, and may be quantified better by non-Gaussian modeling. The aim of this study was to investigate non-Gaussian diffusion in healthy and hypertrophic hearts. METHODS: Thirteen rat hearts (five healthy, four sham, four hypertrophic) were imaged ex vivo. Diffusion-weighted images were acquired at b-values up to 10,000 s/mm2 . Models of diffusion were fit to the data and ranked based on the Akaike information criterion. RESULTS: The diffusion tensor was ranked best at b-values up to 2000 s/mm2 but reflected the signal poorly in the high b-value regime, in which the best model was a non-Gaussian "beta distribution" model. Although there was considerable overlap in apparent diffusivities between the healthy, sham, and hypertrophic hearts, diffusion kurtosis and skewness in the hypertrophic hearts were more than 20% higher in the sheetlet and sheetlet-normal directions. CONCLUSION: Non-Gaussian diffusion models have a higher sensitivity for the detection of hypertrophy compared with the Gaussian model. In particular, diffusion kurtosis may serve as a useful biomarker for characterization of disease and remodeling in the heart. Magn Reson Med 78:1174-1186, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Animais , Cardiomegalia/diagnóstico por imagem , Masculino , Distribuição Normal , Ratos , Ratos Sprague-Dawley
10.
J Electron Imaging ; 26(6)2017 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-29225433

RESUMO

In this work we propose to combine a supervoxel-based image representation with the concept of graph cuts as an efficient optimization technique for 3D deformable image registration. Due to the pixels/voxels-wise graph construction, the use of graph cuts in this context has been mainly limited to 2D applications. However, our work overcomes some of the previous limitations by posing the problem on a graph created by adjacent supervoxels, where the number of nodes in the graph is reduced from the number of voxels to the number of supervoxels. We demonstrate how a supervoxel image representation, combined with graph cuts-based optimization can be applied to 3D data. We further show that the application of a relaxed graph representation of the image, followed by guided image filtering over the estimated deformation field, allows us to model 'sliding motion'. Applying this method to lung image registration, results in highly accurate image registration and anatomically plausible estimations of the deformations. Evaluation of our method on a publicly available Computed Tomography lung image dataset (www.dir-lab.com) leads to the observation that our new approach compares very favorably with state-of-the-art in continuous and discrete image registration methods achieving Target Registration Error of 1.16mm on average per landmark.

11.
Magn Reson Med ; 76(1): 248-58, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26302363

RESUMO

PURPOSE: Diffusion MRI requires acquisition of multiple diffusion-weighted images, resulting in long scan times. Here, we investigate combining compressed sensing and a fast imaging sequence to dramatically reduce acquisition times in cardiac diffusion MRI. METHODS: Fully sampled and prospectively undersampled diffusion tensor imaging data were acquired in five rat hearts at acceleration factors of between two and six using a fast spin echo (FSE) sequence. Images were reconstructed using a compressed sensing framework, enforcing sparsity by means of decomposition by adaptive dictionaries. A tensor was fit to the reconstructed images and fiber tractography was performed. RESULTS: Acceleration factors of up to six were achieved, with a modest increase in root mean square error of mean apparent diffusion coefficient (ADC), fractional anisotropy (FA), and helix angle. At an acceleration factor of six, mean values of ADC and FA were within 2.5% and 5% of the ground truth, respectively. Marginal differences were observed in the fiber tracts. CONCLUSION: We developed a new k-space sampling strategy for acquiring prospectively undersampled diffusion-weighted data, and validated a novel compressed sensing reconstruction algorithm based on adaptive dictionaries. The k-space undersampling and FSE acquisition each reduced acquisition times by up to 6× and 8×, respectively, as compared to fully sampled spin echo imaging. Magn Reson Med 76:248-258, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Compressão de Dados/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Coração/anatomia & histologia , Aumento da Imagem/métodos , Reconhecimento Automatizado de Padrão/métodos , Técnica de Subtração , Animais , Interpretação de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
12.
Europace ; 18(9): 1287-98, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26622055

RESUMO

Both biomedical research and clinical practice rely on complex datasets for the physiological and genetic characterization of human hearts in health and disease. Given the complexity and variety of approaches and recordings, there is now growing recognition of the need to embed computational methods in cardiovascular medicine and science for analysis, integration and prediction. This paper describes a Workshop on Computational Cardiovascular Science that created an international, interdisciplinary and inter-sectorial forum to define the next steps for a human-based approach to disease supported by computational methodologies. The main ideas highlighted were (i) a shift towards human-based methodologies, spurred by advances in new in silico, in vivo, in vitro, and ex vivo techniques and the increasing acknowledgement of the limitations of animal models. (ii) Computational approaches complement, expand, bridge, and integrate in vitro, in vivo, and ex vivo experimental and clinical data and methods, and as such they are an integral part of human-based methodologies in pharmacology and medicine. (iii) The effective implementation of multi- and interdisciplinary approaches, teams, and training combining and integrating computational methods with experimental and clinical approaches across academia, industry, and healthcare settings is a priority. (iv) The human-based cross-disciplinary approach requires experts in specific methodologies and domains, who also have the capacity to communicate and collaborate across disciplines and cross-sector environments. (v) This new translational domain for human-based cardiology and pharmacology requires new partnerships supported financially and institutionally across sectors. Institutional, organizational, and social barriers must be identified, understood and overcome in each specific setting.


Assuntos
Cardiologia/métodos , Fármacos Cardiovasculares/uso terapêutico , Cardiopatias , Farmacologia/métodos , Pesquisa Translacional Biomédica/métodos , Animais , Biomarcadores/metabolismo , Técnicas de Imagem Cardíaca , Cardiotoxicidade , Fármacos Cardiovasculares/efeitos adversos , Comportamento Cooperativo , Difusão de Inovações , Técnicas Eletrofisiológicas Cardíacas , Cardiopatias/diagnóstico por imagem , Cardiopatias/tratamento farmacológico , Cardiopatias/metabolismo , Cardiopatias/fisiopatologia , Humanos , Comunicação Interdisciplinar , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Valor Preditivo dos Testes , Prognóstico , Parcerias Público-Privadas
13.
Magn Reson Med ; 73(6): 2398-405, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25045897

RESUMO

PURPOSE: (i) To optimize an MR-compatible organ perfusion setup for the nondestructive investigation of isolated rat hearts by placing the radiofrequency (RF) coil inside the perfusion chamber; (ii) to characterize the benefit of this system for diffusion tensor imaging and proton ((1) H-) MR spectroscopy. METHODS: Coil quality assessment was conducted both on the bench, and in the magnet. The benefit of the new RF-coil was quantified by measuring signal-to-noise ratio (SNR), accuracy, and precision of diffusion tensor imaging/error in metabolite amplitude estimation, and compared to an RF-coil placed externally to the perfusion chamber. RESULTS: The new design provided a 59% gain in signal-to-noise ratio on a fixed rat heart compared to using an external resonator, which found reflection in an improvement of living heart data quality, compared to previous external resonator studies. This resulted in 14-29% improvement in accuracy and precision of diffusion tensor imaging. The Cramer-Rao lower bounds for metabolite amplitude estimations were up to 5-fold smaller. CONCLUSION: Optimization of MR-compatible perfusion equipment advances the study of rat hearts with improved signal-to-noise ratio performance, and thus improved accuracy/precision.


Assuntos
Coração/anatomia & histologia , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Animais , Desenho de Equipamento , Ratos , Ratos Sprague-Dawley , Razão Sinal-Ruído
14.
Europace ; 16 Suppl 4: iv86-iv95, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25362175

RESUMO

AIMS: Cardiac histo-anatomical organization is a major determinant of function. Changes in tissue structure are a relevant factor in normal and disease development, and form targets of therapeutic interventions. The purpose of this study was to test tools aimed to allow quantitative assessment of cell-type distribution from large histology and magnetic resonance imaging- (MRI) based datasets. METHODS AND RESULTS: Rabbit heart fixation during cardioplegic arrest and MRI were followed by serial sectioning of the whole heart and light-microscopic imaging of trichrome-stained tissue. Segmentation techniques developed specifically for this project were applied to segment myocardial tissue in the MRI and histology datasets. In addition, histology slices were segmented into myocytes, connective tissue, and undefined. A bounding surface, containing the whole heart, was established for both MRI and histology. Volumes contained in the bounding surface (called 'anatomical volume'), as well as that identified as containing any of the above tissue categories (called 'morphological volume'), were calculated. The anatomical volume was 7.8 cm(3) in MRI, and this reduced to 4.9 cm(3) after histological processing, representing an 'anatomical' shrinkage by 37.2%. The morphological volume decreased by 48% between MRI and histology, highlighting the presence of additional tissue-level shrinkage (e.g. an increase in interstitial cleft space). The ratio of pixels classified as containing myocytes to pixels identified as non-myocytes was roughly 6:1 (61.6 vs. 9.8%; the remaining fraction of 28.6% was 'undefined'). CONCLUSION: Qualitative and quantitative differentiation between myocytes and connective tissue, using state-of-the-art high-resolution serial histology techniques, allows identification of cell-type distribution in whole-heart datasets. Comparison with MRI illustrates a pronounced reduction in anatomical and morphological volumes during histology processing.


Assuntos
Simulação por Computador , Coração/fisiopatologia , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Modelos Cardiovasculares , Miocárdio/patologia , Animais , Gráficos por Computador , Feminino , Parada Cardíaca Induzida , Interpretação de Imagem Assistida por Computador , Modelos Animais , Miócitos Cardíacos/patologia , Coelhos
15.
Artigo em Inglês | MEDLINE | ID: mdl-38648144

RESUMO

Global single-valued biomarkers, such as ejection fraction, are widely used in clinical practice to assess cardiac function. However, they only approximate the heart's true 3D deformation process, thus limiting diagnostic accuracy and the understanding of cardiac mechanics. Metrics based on 3D shape have been proposed to alleviate these shortcomings. In this work, we present the Point Cloud Deformation Network (PCD-Net) as a novel geometric deep learning approach for direct modeling of 3D cardiac mechanics of the biventricular anatomy between the extreme ends of the cardiac cycle. Its encoder-decoder architecture combines a low-dimensional latent space with recent advances in point cloud deep learning for effective multi-scale feature learning directly on flexible and memory-efficient point cloud representations of the cardiac anatomy. We first evaluate the PCD-Net's predictive ability for both cardiac contraction and relaxation on a large U.K. Biobank dataset of over 10,000 subjects and find average Chamfer distances between the predicted and ground truth anatomies below the pixel resolution of the underlying image acquisition. We then show the PCD-Net's suitability to act as a normality model of 3D cardiac mechanics and capture subpopulation-specific differences between normal subjects and myocardial infarction (MI) patients. Next, we highlight the PCD-Net's interpretability by visualizing abnormal phenotypes between predicted normal 3D shapes and corresponding observed ones. Finally, we demonstrate that the PCD-Net's learned 3D deformation encodings outperform multiple clinical and machine learning benchmarks by 11% in terms of area under the receiver operating characteristic curve for the tasks of prevalent MI detection and incident MI prediction and by 7% in terms of Harrell's concordance index for MI survival analysis.

16.
IEEE Trans Med Imaging ; 43(7): 2466-2478, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38373128

RESUMO

Cardiac digital twins (CDTs) have the potential to offer individualized evaluation of cardiac function in a non-invasive manner, making them a promising approach for personalized diagnosis and treatment planning of myocardial infarction (MI). The inference of accurate myocardial tissue properties is crucial in creating a reliable CDT of MI. In this work, we investigate the feasibility of inferring myocardial tissue properties from the electrocardiogram (ECG) within a CDT platform. The platform integrates multi-modal data, such as cardiac MRI and ECG, to enhance the accuracy and reliability of the inferred tissue properties. We perform a sensitivity analysis based on computer simulations, systematically exploring the effects of infarct location, size, degree of transmurality, and electrical activity alteration on the simulated QRS complex of ECG, to establish the limits of the approach. We subsequently present a novel deep computational model, comprising a dual-branch variational autoencoder and an inference model, to infer infarct location and distribution from the simulated QRS. The proposed model achieves mean Dice scores of 0.457 ±0.317 and 0.302 ±0.273 for the inference of left ventricle scars and border zone, respectively. The sensitivity analysis enhances our understanding of the complex relationship between infarct characteristics and electrophysiological features. The in silico experimental results show that the model can effectively capture the relationship for the inverse inference, with promising potential for clinical application in the future. The code is available at https://github.com/lileitech/MI_inverse_inference.


Assuntos
Eletrocardiografia , Imageamento por Ressonância Magnética , Infarto do Miocárdio , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Humanos , Eletrocardiografia/métodos , Imageamento por Ressonância Magnética/métodos , Simulação por Computador , Coração/diagnóstico por imagem , Aprendizado Profundo , Algoritmos
17.
J Thorac Imaging ; 39(2): 79-85, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37889567

RESUMO

PURPOSE: This study aimed to determine the association between functional impairment in small airways and symptoms of dyspnea in patients with Long-coronavirus disease (COVID), using imaging and computational modeling analysis. PATIENTS AND METHODS: Thirty-four patients with Long-COVID underwent thoracic computed tomography and hyperpolarized Xenon-129 magnetic resonance imaging (HP Xe MRI) scans. Twenty-two answered dyspnea-12 questionnaires. We used a computed tomography-based full-scale airway network (FAN) flow model to simulate pulmonary ventilation. The ventilation distribution projected on a coronal plane and the percentage lobar ventilation modeled in the FAN model were compared with the HP Xe MRI data. To assess the ventilation heterogeneity in small airways, we calculated the fractal dimensions of the impaired ventilation regions in the HP Xe MRI and FAN models. RESULTS: The ventilation distribution projected on a coronal plane showed an excellent resemblance between HP Xe MRI scans and FAN models (structure similarity index: 0.87 ± 0.04). In both the image and the model, the existence of large clustered ventilation defects was not identifiable regardless of dyspnea severity. The percentage lobar ventilation of the HP Xe MRI and FAN model showed a strong correlation (ρ = 0.63, P < 0.001). The difference in the fractal dimension of impaired ventilation zones between the low and high dyspnea-12 score groups was significant (HP Xe MRI: 1.97 [1.89 to 2.04] and 2.08 [2.06 to 2.14], P = 0.005; FAN: 2.60 [2.59 to 2.64] and 2.64 [2.63 to 2.65], P = 0.056). CONCLUSIONS: This study has identified a potential association of small airway functional impairment with breathlessness in Long-COVID, using fractal analysis of HP Xe MRI scans and FAN models.


Assuntos
Síndrome de COVID-19 Pós-Aguda , Isótopos de Xenônio , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Respiração , Imageamento por Ressonância Magnética/métodos , Dispneia/diagnóstico por imagem
18.
Med Image Anal ; 92: 103061, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38086235

RESUMO

The Segment Anything Model (SAM) is the first foundation model for general image segmentation. It has achieved impressive results on various natural image segmentation tasks. However, medical image segmentation (MIS) is more challenging because of the complex modalities, fine anatomical structures, uncertain and complex object boundaries, and wide-range object scales. To fully validate SAM's performance on medical data, we collected and sorted 53 open-source datasets and built a large medical segmentation dataset with 18 modalities, 84 objects, 125 object-modality paired targets, 1050K 2D images, and 6033K masks. We comprehensively analyzed different models and strategies on the so-called COSMOS 1050K dataset. Our findings mainly include the following: (1) SAM showed remarkable performance in some specific objects but was unstable, imperfect, or even totally failed in other situations. (2) SAM with the large ViT-H showed better overall performance than that with the small ViT-B. (3) SAM performed better with manual hints, especially box, than the Everything mode. (4) SAM could help human annotation with high labeling quality and less time. (5) SAM was sensitive to the randomness in the center point and tight box prompts, and may suffer from a serious performance drop. (6) SAM performed better than interactive methods with one or a few points, but will be outpaced as the number of points increases. (7) SAM's performance correlated to different factors, including boundary complexity, intensity differences, etc. (8) Finetuning the SAM on specific medical tasks could improve its average DICE performance by 4.39% and 6.68% for ViT-B and ViT-H, respectively. Codes and models are available at: https://github.com/yuhoo0302/Segment-Anything-Model-for-Medical-Images. We hope that this comprehensive report can help researchers explore the potential of SAM applications in MIS, and guide how to appropriately use and develop SAM.


Assuntos
Diagnóstico por Imagem , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos
19.
Med Image Anal ; 94: 103108, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38447244

RESUMO

Cardiac in silico clinical trials can virtually assess the safety and efficacy of therapies using human-based modelling and simulation. These technologies can provide mechanistic explanations for clinically observed pathological behaviour. Designing virtual cohorts for in silico trials requires exploiting clinical data to capture the physiological variability in the human population. The clinical characterisation of ventricular activation and the Purkinje network is challenging, especially non-invasively. Our study aims to present a novel digital twinning pipeline that can efficiently generate and integrate Purkinje networks into human multiscale biventricular models based on subject-specific clinical 12-lead electrocardiogram and magnetic resonance recordings. Essential novel features of the pipeline are the human-based Purkinje network generation method, personalisation considering ECG R wave progression as well as QRS morphology, and translation from reduced-order Eikonal models to equivalent biophysically-detailed monodomain ones. We demonstrate ECG simulations in line with clinical data with clinical image-based multiscale models with Purkinje in four control subjects and two hypertrophic cardiomyopathy patients (simulated and clinical QRS complexes with Pearson's correlation coefficients > 0.7). Our methods also considered possible differences in the density of Purkinje myocardial junctions in the Eikonal-based inference as regional conduction velocities. These differences translated into regional coupling effects between Purkinje and myocardial models in the monodomain formulation. In summary, we demonstrate a digital twin pipeline enabling simulations yielding clinically consistent ECGs with clinical CMR image-based biventricular multiscale models, including personalised Purkinje in healthy and cardiac disease conditions.


Assuntos
Imageamento por Ressonância Magnética , Ramos Subendocárdicos , Humanos , Ramos Subendocárdicos/diagnóstico por imagem , Ramos Subendocárdicos/anatomia & histologia , Ramos Subendocárdicos/fisiologia , Miocárdio , Simulação por Computador , Eletrocardiografia/métodos
20.
Sci Rep ; 14(1): 8951, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637609

RESUMO

This study aims at identifying risk-related patterns of left ventricular contraction dynamics via novel volume transient characterization. A multicenter cohort of AMI survivors (n = 1021) who underwent Cardiac Magnetic Resonance (CMR) after infarction was considered for the study. The clinical endpoint was the 12-month rate of major adverse cardiac events (MACE, n = 73), consisting of all-cause death, reinfarction, and new congestive heart failure. Cardiac function was characterized from CMR in 3 potential directions: by (1) volume temporal transients (i.e. contraction dynamics); (2) feature tracking strain analysis (i.e. bulk tissue peak contraction); and (3) 3D shape analysis (i.e. 3D contraction morphology). A fully automated pipeline was developed to extract conventional and novel artificial-intelligence-derived metrics of cardiac contraction, and their relationship with MACE was investigated. Any of the 3 proposed directions demonstrated its additional prognostic value on top of established CMR indexes, myocardial injury markers, basic characteristics, and cardiovascular risk factors (P < 0.001). The combination of these 3 directions of enhancement towards a final CMR risk model improved MACE prediction by 13% compared to clinical baseline (0.774 (0.771-0.777) vs. 0.683 (0.681-0.685) cross-validated AUC, P < 0.001). The study evidences the contribution of the novel contraction characterization, enabled by a fully automated pipeline, to post-infarction assessment.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Função Ventricular Esquerda , Humanos , Volume Sistólico , Fatores de Risco , Medição de Risco , Prognóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/patologia , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA