Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 48(5): 1570-1584, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33433699

RESUMO

PURPOSE: A multidisciplinary expert panel convened to formulate state-of-the-art recommendations for optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (90Y)-resin microspheres. METHODS: A steering committee of 23 international experts representing all participating specialties formulated recommendations for SIRT with 90Y-resin microspheres activity prescription and post-treatment dosimetry, based on literature searches and the responses to a 61-question survey that was completed by 43 leading experts (including the steering committee members). The survey was validated by the steering committee and completed anonymously. In a face-to-face meeting, the results of the survey were presented and discussed. Recommendations were derived and level of agreement defined (strong agreement ≥ 80%, moderate agreement 50%-79%, no agreement ≤ 49%). RESULTS: Forty-seven recommendations were established, including guidance such as a multidisciplinary team should define treatment strategy and therapeutic intent (strong agreement); 3D imaging with CT and an angiography with cone-beam-CT, if available, and 99mTc-MAA SPECT/CT are recommended for extrahepatic/intrahepatic deposition assessment, treatment field definition and calculation of the 90Y-resin microspheres activity needed (moderate/strong agreement). A personalised approach, using dosimetry (partition model and/or voxel-based) is recommended for activity prescription, when either whole liver or selective, non-ablative or ablative SIRT is planned (strong agreement). A mean absorbed dose to non-tumoural liver of 40 Gy or less is considered safe (strong agreement). A minimum mean target-absorbed dose to tumour of 100-120 Gy is recommended for hepatocellular carcinoma, liver metastatic colorectal cancer and cholangiocarcinoma (moderate/strong agreement). Post-SIRT imaging for treatment verification with 90Y-PET/CT is recommended (strong agreement). Post-SIRT dosimetry is also recommended (strong agreement). CONCLUSION: Practitioners are encouraged to work towards adoption of these recommendations.


Assuntos
Embolização Terapêutica , Neoplasias Hepáticas , Humanos , Neoplasias Hepáticas/radioterapia , Microesferas , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Agregado de Albumina Marcado com Tecnécio Tc 99m , Radioisótopos de Ítrio/uso terapêutico
2.
Eur Radiol ; 27(9): 3625-3634, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28168371

RESUMO

OBJECTIVES: The objective of this study was to assess the influence of an iterative CT reconstruction algorithm (IA), newly available for CT-fluoroscopy (CTF), on image noise, readers' confidence and effective dose compared to filtered back projection (FBP). METHODS: Data from 165 patients (FBP/IA = 82/74) with CTF in the thorax, abdomen and pelvis were included. Noise was analysed in a large-diameter vessel. The impact of reconstruction and variables (e.g. X-ray tube current I) influencing noise and effective dose were analysed by ANOVA and a pairwise t-test with Bonferroni-Holm correction. Noise and readers' confidence were evaluated by three readers. RESULTS: Noise was significantly influenced by reconstruction, I, body region and circumference (all p ≤ 0.0002). IA reduced the noise significantly compared to FBP (p = 0.02). The effect varied for body regions and circumferences (p ≤ 0.001). The effective dose was influenced by the reconstruction, body region, interventional procedure and I (all p ≤ 0.02). The inter-rater reliability for noise and readers' confidence was good (W ≥ 0.75, p < 0.0001). Noise and readers' confidence were significantly better in AIDR-3D compared to FBP (p ≤ 0.03). Generally, IA yielded a significant reduction of the median effective dose. CONCLUSION: The CTF reconstruction by IA showed a significant reduction in noise and effective dose while readers' confidence increased. KEY POINTS: • CTF is performed for image guidance in interventional radiology. • Patient exposure was estimated from DLP documented by the CT. • Iterative CT reconstruction is appropriate to reduce image noise in CTF. • Using iterative CT reconstruction, the effective dose was significantly reduced in abdominal interventions.


Assuntos
Fluoroscopia/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Pelve/diagnóstico por imagem , Melhoria de Qualidade , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Intervencionista/métodos , Reprodutibilidade dos Testes , Tórax/diagnóstico por imagem
3.
J Vasc Interv Radiol ; 26(11): 1615-21, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26321017

RESUMO

PURPOSE: To retrospectively assess the influence of the parameters of the body surface area (BSA) method in hepatic radioembolization using yttrium-90-labeled microspheres on the determination of the prescribed activity. MATERIALS AND METHODS: Data from 283 consecutive patients treated with radioembolization (BSA method) were included. For interindividual comparisons, activity concentrations (ACs; MBq/mL) were calculated for each liver. The impact of the BSA method parameters was assessed by analysis of variance and pairwise t test with Bonferroni-Holm correction. RESULTS: Prescribed activity was 1.01-2.71 GBq, with BSA, liver volume (LV), tumor burden, and the liver-lung shunt reduction factor (LLS RF) being significant contributing factors to the AC (all P < .0001, analysis of variance). BSA and LV correlated only moderately (ρ = 0.46, P < .0001). Compared with base activity defined by the BSA (median = 1.67 GBq; range, 1.20-2.32 GBq), the activity contribution of tumor burden was small (median = 150 MBq; range, 3-800 MBq). Resulting activities were reduced according to LLS RF by 20% in 12.4% and by 40% in 3.5% of patients. AC was significantly (up to 56%) lower in association with larger LV than in small LV (LV < 1,500 mL vs ≥ 2,500 mL, P < .0001). CONCLUSIONS: In the BSA model, BSA and LV showed only a moderate correlation, resulting in a significantly lower AC in patients with larger livers. Tumor burden percentage contributed little to the prescribed activity because the BSA model did not account for actual LVs and tumor volumes. These inaccuracies may potentially result in underdosage in patients with larger livers, especially if further LLS RF needs to be applied.


Assuntos
Superfície Corporal , Neoplasias Hepáticas/fisiopatologia , Neoplasias Hepáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Ítrio/uso terapêutico , Braquiterapia/métodos , Simulação por Computador , Resinas Epóxi , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico , Masculino , Microesferas , Pessoa de Meia-Idade , Modelos Biológicos , Radiometria , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Radioisótopos de Ítrio/análise
4.
BMC Med Imaging ; 15: 18, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-26033371

RESUMO

BACKGROUND: The diagnosis of hip pain after total hip replacement (THR) represents a highly challenging question that is of increasing concern to orthopedic surgeons. This retrospective study assesses bone scintigraphy with Hybrid SPECT/CT for the diagnosis of painful THR in a selected cohort of patients. METHODS: Bone SPECT/CT datasets of 23 patients (mean age 68.9 years) with a painful hip after THR were evaluated. Selection of the patients required an inconclusive radiograph, normal serum levels of inflammatory parameters (CRP and ESR) or a negative aspiration of the hip joint prior to the examination. The standard of reference was established by an interdisciplinary adjudication-panel using all imaging data and clinical follow-up data (>12 month). Pathological and physiological uptake patterns were defined and applied. RESULTS: The cause of pain in this study group could be determined in 18 out of 23 cases. Reasons were aseptic loosening (n = 5), spine-related (n = 5), heterotopic ossification (n = 5), neuronal (n = 1), septic loosening (n = 1) and periprosthetic stress fracture (n = 1). In (n = 5) cases the cause of hip pain could not be identified. SPECT/CT imaging correctly identified the cause of pain in (n = 13) cases, in which the integrated CT-information led to the correct diagnosis in (n = 4) cases, mainly through superior anatomic correlation. Loosening was correctly assessed in all cases with a definite diagnosis. CONCLUSIONS: SPECT/CT of THA reliably detects or rules out loosening and provides valuable information about heterotopic ossifications. Furthermore differential diagnoses may be detected with a whole-body scan and mechanical or osseous failure is covered by CT-imaging. SPECT/CT holds great potential for imaging-based assessment of painful prostheses.


Assuntos
Artralgia/diagnóstico , Artralgia/etiologia , Artroplastia de Quadril/efeitos adversos , Articulação do Quadril/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Idoso , Cimentos Ósseos , Feminino , Humanos , Masculino , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
5.
Neuroimage ; 103: 171-180, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25234116

RESUMO

Electrical and optogenetic methods for brain stimulation are widely used in rodents for manipulating behavior and analyzing functional connectivities in neuronal circuits. High-resolution in vivo imaging of the global, brain-wide, activation patterns induced by these stimulations has remained challenging, in particular in awake behaving mice. We here mapped brain activation patterns in awake, intracranially self-stimulating mice using a novel protocol for single-photon emission computed tomography (SPECT) imaging of regional cerebral blood flow (rCBF). Mice were implanted with either electrodes for electrical stimulation of the medial forebrain bundle (mfb-microstim) or with optical fibers for blue-light stimulation of channelrhodopsin-2 expressing neurons in the ventral tegmental area (vta-optostim). After training for self-stimulation by current or light application, respectively, mice were implanted with jugular vein catheters and intravenously injected with the flow tracer 99m-technetium hexamethylpropyleneamine oxime (99mTc-HMPAO) during seven to ten minutes of intracranial self-stimulation or ongoing behavior without stimulation. The 99mTc-brain distributions were mapped in anesthetized animals after stimulation using multipinhole SPECT. Upon self-stimulation rCBF strongly increased at the electrode tip in mfb-microstim mice. In vta-optostim mice peak activations were found outside the stimulation site. Partly overlapping brain-wide networks of activations and deactivations were found in both groups. When testing all self-stimulating mice against all controls highly significant activations were found in the rostromedial nucleus accumbens shell. SPECT-imaging of rCBF using intravenous tracer-injection during ongoing behavior is a new tool for imaging regional brain activation patterns in awake behaving rodents providing higher spatial and temporal resolutions than 18F-2-fluoro-2-dexoyglucose positron emission tomography.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Optogenética/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Encéfalo/irrigação sanguínea , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Compostos Radiofarmacêuticos , Recompensa , Autoestimulação , Tecnécio Tc 99m Exametazima
6.
Med Phys ; 51(10): 7574-7579, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38922963

RESUMO

BACKGROUND: Historically, [131I]I has been a common isotope in radionuclide therapy, with [177Lu]Lu-labelled radiopharmaceuticals now seeing a surge in use. These can include no-carrier-added or carrier-added [177Lu]Lu with slight impurities of [177mLu]Lu with a significantly longer half-life than [131I]I. Wastewater from therapy wards can contain a mixture of these radioisotopes. In some countries, national regulations require wastewater to be stored in dedicated systems before it is discharged into the public sewage system. To fulfill legal requirements, the nuclide specific activity concentration must be verified. PURPOSE: We evaluate a method for determining the activity concentration of [177mLu]Lu /[177Lu]Lu at equilibrium and [131I]I in pure and mixed samples in order to prove that the determined values are reliably below the limits for release. METHODS: We analysed the emitted energy spectrum of 1 L samples with a wastewater counter using an energy window-based approach by evaluating measurements from two different time points. Based on the law of decay and the time and energy-dependent measured values, equation systems were set up to calculate the count rates for [131I]I and [177mLu]Lu, which were converted into activity concentration using calibration factors. RESULTS: There is strong linear correlation between the nominal and determined activity concentrations (correlation coefficients R = 0.99; coefficient of determinations R2 = 0.99). We underestimate the actual activity concentration by a median of -1.4% for [177mLu]Lu and overestimate the activity concentration for [131I]I by a median of 7.1%. CONCLUSION: We show that an undercut of the clearance levels for material release is measurable. We analyse and determine activity concentrations of mixed samples consisting of [131I]I and [177mLu]Lu/[177Lu]Lu in equilibrium. The method is simple to implement using a conventional wastewater counter, however with a slightly increased effort, as two samples and measurements are required. The methodology can be adapted for the analysis of other nuclide mixtures.


Assuntos
Hospitais , Radioisótopos do Iodo , Lutécio , Radioisótopos , Águas Residuárias , Radioisótopos/análise , Radioisótopos do Iodo/análise , Poluentes Radioativos da Água/análise
7.
Bioengineering (Basel) ; 11(8)2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-39199796

RESUMO

Dose optimization in computed tomography (CT) is crucial, especially in CT fluoroscopy (fluoro-CT) used for real-time navigation, affecting both patient and operator safety. This study evaluated the impact of spectral X-ray filtering using a tin filter (Sn filter), and a method called partial-angle computed tomography (PACT), which involves segmentally switching off the X-ray tube current at the ambient dose rate H˙*(10) at the interventional radiologist's (IR) position. Measurements were taken at two body regions (upper body: head/neck; lower body: lower legs/feet) using a 120 kV X-ray tube voltage, 3 × 5.0 mm CT collimation, 0.5 s rotation speed, and X-ray tube currents of 43 Eff.mAs (without Sn filter) and 165 Eff.mAs (with Sn filter). The study found significant dose reductions in both body regions when using the Sn filter and PACT together. For instance, in the upper body region, the combination protocol reduced H˙*(10) from 11.8 µSv/s to 6.1 µSv/s (p < 0.0001) compared to the protocol without using these features. Around 8% of the reduction (about 0.5 µSv/s) is attributed to the Sn filter (p = 0.0005). This approach demonstrates that using the Sn filter along with PACT effectively minimizes radiation exposure for the IR, particularly protecting areas like the head/neck, which can only be insufficiently covered by (standard) radiation protection material.

8.
Eur Radiol Exp ; 8(1): 15, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38282160

RESUMO

BACKGROUND: To compare Gd-ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and 99mTc-labelled mebrofenin hepatobiliary scintigraphy (HBS) as imaging-based liver function tests after unilateral radioembolisation (RE) in patients with primary or secondary liver malignancies. METHODS: Twenty-three patients with primary or secondary liver malignancies who underwent Gd-EOB-DTPA-enhanced MRI within a prospective study (REVoluTion) were evaluated. REVoluTion was a prospective open-label, non-randomised, therapy-optimising study of patients undergoing right-sided or sequential RE for contralateral liver hypertrophy at a single centre in Germany. MRI and hepatobiliary scintigraphy were performed before RE (baseline) and 6 weeks after (follow-up). This exploratory subanalysis compared liver enhancement on hepatobiliary phase MRI normalised to the spleen (liver-to-spleen ratio (LSR)) and the muscle (liver-to-muscle ratio (LMR)) with mebrofenin uptake on HBS for the total liver (TL) and separately for the right (RLL) and left liver lobe (LLL). RESULTS: Mebrofenin uptake at baseline and follow-up each correlated significantly with LSR and LMR on MRI for TL (≤ 0.013) and RLL (≤ 0.049). Regarding the LLL, mebrofenin uptake correlated significantly with LMR (baseline, p = 0.013; follow-up, p = 0.004), whereas with LSR, a borderline significant correlation was only seen at follow-up (p = 0.051; p = 0.046). CONCLUSION: LSRs and LMR correlate with mebrofenin uptake in HBS. This study indicates that Gd-EOB-DTPA-enhanced MRI and 99mTc-labelled mebrofenin HBS may equally be used to assess an increase in contralateral liver lobe function after right-sided RE. RELEVANCE STATEMENT: MRI may be a convenient and reliable method for assessing the future liver remnant facilitating treatment planning and monitoring of patients after RE-induced hypertrophy induction. KEY POINTS: • Both MRI and HBS can assess liver function after RE. • Liver enhancement on MRI correlates with mebrofenin uptake on HBS. • MRI might be a convenient alternative for estimating future liver remnants after hypertrophy induction.


Assuntos
Compostos de Anilina , Gadolínio DTPA , Glicina , Neoplasias Hepáticas , Compostos Radiofarmacêuticos , Humanos , Estudos Prospectivos , Cintilografia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Imageamento por Ressonância Magnética/métodos , Ácido Pentético , Hipertrofia
9.
EJNMMI Radiopharm Chem ; 9(1): 26, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551764

RESUMO

BACKGROUND: To investigate the capacity of 99mTc-labeled 1-thio-ß-D-glucose (1-TG) and 5-thio-D-glucose (5-TG) to act as a marker for glucose consumption in tumor cells in vivo as well as to evaluate the biodistribution of 1-TG and 5-TG. We investigated the biodistribution, including tumor uptake, of 1-TG and 5-TG at various time points after injection (0.5, 2 and 4 h) in human colorectal carcinoma (HCT-116) and human lung adenocarcinoma (A549) xenograft bearing nude mice (N = 4 per tracer and time point). RESULTS: Ex vivo biodistribution studies revealed a moderate uptake with a maximum tumor-to-muscle ratio of 4.22 ± 2.7 and 2.2 ± 1.3 (HCT-116) and of 3.2 ± 1.1 and 4.1 ± 1.3 (A549) for 1-TG and 5-TG, respectively, with a peak at 4 h for 1-TG and 5-TG. Biodistribution revealed a significantly higher uptake compared to blood in kidneys (12.18 ± 8.77 and 12.69 ± 8.93%ID/g at 30 min) and liver (2.6 ± 2.8%ID/g) for 1-TG and in the lung (7.24 ± 4.1%ID/g), liver (6.38 ± 2.94%ID/g), and kidneys (4.71 ± 1.97 and 4.81 ± 1.91%ID/g) for 5-TG. CONCLUSIONS: 1-TG and 5-TG showed an insufficient tumor uptake with a moderate tumor-to-muscle ratio, not reaching the levels of commonly used tracer, for diagnostic use in human colorectal carcinoma and human lung adenocarcinoma xenograft model.

10.
Med Phys ; 50(1): 590-599, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36208077

RESUMO

BACKGROUND: Nuclear medicine therapies using [177 Lu]Lu-labeled radiopharmaceuticals have increased significantly in recent years. Some of these radiopharmaceuticals contain long-lived impurities of [177m Lu]Lu. Identification of this specific contamination and its quantification is important in different scenarios. PURPOSE: In this study, standard measurement hardware used for handling radioisotopes was evaluated for the measurement of [177m Lu]Lu and [177 Lu]Lu at equilibrium. Device-specific detection limits (LODs) for [177m Lu]Lu were determined according to international standards and then validated. METHODS: The LODs were determined according to the international standard ISO 11929-1 for [177m Lu]Lu for five identical portable contamination monitors (PCMs), a wastewater counter (WWC), and a release counter system (RCS) at different measuring times. Subsequent activity measurements of the defined samples were used to validate the linearity of the measurement instruments down to the LOD for each system. RESULTS: The average LOD across all PCMs was 0.249 ± 0.009 and 0.129 ± 0.005 Bq/cm2 for 10 and 30 s measurements, respectively. The LODs of WWC varied between 3.3 and 4.7 Bq/L for measurement times of 300 s and 0.8-1.3 Bq/L for 3600 s depending on the energy window studied. The LOD of the RCS depended on the container volume and was 0.08 Bq/g for the 50 L container at 60 s measurement. The measurements for all examined devices were linear down to the LOD (correlation coefficient R ≥ 0.96; coefficient of determination R2  ≥ 0.92). CONCLUSIONS: All investigated measuring instruments (PCM, WWC, RCS) were suitable for the determination of [177m Lu]Lu at equilibrium, and their specific LODs were determined. Based on the measurements performed, activity is overestimated; however, this is tolerable because assumptions and measurements in the context of radiation protection should be conservative.


Assuntos
Medicina Nuclear , Compostos Radiofarmacêuticos , Lutécio , Radioisótopos , Padrões de Referência
12.
EJNMMI Phys ; 8(1): 57, 2021 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-34328565

RESUMO

BACKGROUND: The introduction of hybrid SPECT/CT devices enables quantitative imaging in SPECT, providing a methodological setup for quantitation using SPECT tracers comparable to PET/CT. We evaluated a specific quantitative reconstruction algorithm for SPECT data using a 99mTc-filled NEMA phantom. Quantitative and qualitative image parameters were evaluated for different parametrizations of the acquisition and reconstruction protocol to identify an optimized quantitative protocol. RESULTS: The reconstructed activity concentration (ACrec) and the signal-to-noise ratio (SNR) of all examined protocols (n = 16) were significantly affected by the parametrization of the weighting factor k used in scatter correction, the total number of iterations and the sphere volume (all, p < 0.0001). The two examined SPECT acquisition protocols (with 60 or 120 projections) had a minor impact on the ACrec and no significant impact on the SNR. In comparison to the known AC, the use of default scatter correction (k = 0.47) or object-specific scatter correction (k = 0.18) resulted in an underestimation of ACrec in the largest sphere volume (26.5 ml) by - 13.9 kBq/ml (- 16.3%) and - 7.1 kBq/ml (- 8.4%), respectively. An increase in total iterations leads to an increase in estimated AC and a decrease in SNR. The mean difference between ACrec and known AC decreased with an increasing number of total iterations (e.g., for 20 iterations (2 iterations/10 subsets) = - 14.6 kBq/ml (- 17.1%), 240 iterations (24i/10s) = - 8.0 kBq/ml (- 9.4%), p < 0.0001). In parallel, the mean SNR decreased significantly from 2i/10s to 24i/10s by 76% (p < 0.0001). CONCLUSION: Quantitative SPECT imaging is feasible with the used reconstruction algorithm and hybrid SPECT/CT, and its consistent implementation in diagnostics may provide perspectives for quantification in routine clinical practice (e.g., assessment of bone metabolism). When combining quantitative analysis and diagnostic imaging, we recommend using two different reconstruction protocols with task-specific optimized setups (quantitative vs. qualitative reconstruction). Furthermore, individual scatter correction significantly improves both quantitative and qualitative results.

13.
Ann Surg Open ; 2(3): e095, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37635822

RESUMO

Objectives: To investigate how metabolic function of the contralateral liver lobe is affected by unilateral radioembolization (RE), and to compare the changes in volume and metabolic function. Background: Unilateral RE induces contralateral liver hypertrophy, but it is unknown if metabolic liver function improves in line with volume increases. Methods: This prospective open-label, nonrandomized, therapy-optimizing study included all consecutive patients undergoing right-sided or sequential 90Y-RE for liver malignancies without underlying liver disease or biliary obstruction at a single center in Germany. Magnetic resonance imaging volumetry and hepatobiliary scintigraphy were performed immediately before RE and approximately 6 weeks after RE. Results: Twenty-three patients were evaluated (11 metastatic colorectal cancer, 4 cholangiocellular carcinoma, 3 metastatic breast cancer, 1 each of metastatic neuroendocrine tumor, hepatocellular carcinoma, renal cell carcinoma, oesophageal cancer, pancreatic ductal adenocarcinoma). In the untreated contralateral left liver lobe, mean (SD) metabolic function significantly increased from 1.34 (0.76) %/min/m2 at baseline to 1.56 (0.75) %/min/m2 6 weeks after RE (P = 0.024). The mean (SD) functional volume (liver volume minus tumor volume) of the left liver lobe significantly increased from baseline (407.3 [170.3] mL) to follow-up (499.1 [209.8] mL; P < 0.01), with an equivalent magnitude to the metabolic function increase. There were no reports of grade ≥3 adverse events. Conclusion: This study indicates that unilobar RE produces a significant increase in the metabolic function, and equivalent volume increase, of the contralateral lobe. RE may be a useful option to induce hypertrophy of the future liver remnant before surgical resection of primary or secondary liver malignancies.

14.
EJNMMI Phys ; 8(1): 15, 2021 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-33595735

RESUMO

BACKGROUND: SPECT-CT using radiolabeled phosphonates is considered a standard for assessing bone metabolism (e.g., in patients with osteoarthritis of knee joints). However, SPECT can be influenced by metal artifacts in CT caused by endoprostheses affecting attenuation correction. The current study examined the effects of metal artifacts in CT of a specific endoprosthesis design on quantitative hybrid SPECT-CT imaging. The implant was positioned inside a phantom homogenously filled with activity (955 MBq 99mTc). CT imaging was performed for different X-ray tube currents (I = 10, 40, 125 mA) and table pitches (p = 0.562 and 1.375). X-ray tube voltage (U = 120 kVp) and primary collimation (16 × 0.625 mm) were kept constant for all scans. The CT reconstruction was performed with five different reconstruction kernels (slice thickness, 1.25 mm and 3.75 mm, each 512 × 512 matrix). Effects from metal artifacts were analyzed for different CT scans and reconstruction protocols. ROI analysis of CT and SPECT data was performed for two slice positions/volumes representing the typical locations for target structures relative to the prosthesis (e.g., femur and tibia). A reference region (homogenous activity concentration without influence from metal artifacts) was analyzed for comparison. RESULTS: Significant effects caused by CT metal artifacts on attenuation-corrected SPECT were observed for the different slice positions, reconstructed slice thicknesses of CT data, and pitch and CT-reconstruction kernels used (all, p < 0.0001). Based on the optimization, a set of three protocols was identified minimizing the effect of CT metal artifacts on SPECT data. Regarding the reference region, the activity concentration in the anatomically correlated volume was underestimated by 8.9-10.1%. A slight inhomogeneity of the reconstructed activity concentration was detected inside the regions with a median up to 0.81% (p < 0.0001). Using an X-ray tube current of 40 mA showed the best result, balancing quantification and CT exposure. CONCLUSION: The results of this study demonstrate the need for the evaluation of SPECT-CT protocols in prosthesis imaging. Phantom experiments demonstrated the possibility for quantitative SPECT-CT of bone turnover in a specific prosthesis design. Meanwhile, a systematic bias caused by metal implants on quantitative SPECT data has to be considered.

15.
Cancers (Basel) ; 12(9)2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32957650

RESUMO

The bone scan index (BSI), initially introduced for metastatic prostate cancer, quantifies the osseous tumor load from planar bone scans. Following the basic idea of radiomics, this method incorporates specific deep-learning techniques (artificial neural network) in its development to provide automatic calculation, feature extraction, and diagnostic support. As its performance in tumor entities, not including prostate cancer, remains unclear, our aim was to obtain more data about this aspect. The results of BSI evaluation of bone scans from 951 consecutive patients with different tumors were retrospectively compared to clinical reports (bone metastases, yes/no). Statistical analysis included entity-specific receiver operating characteristics to determine optimized BSI cut-off values. In addition to prostate cancer (cut-off = 0.27%, sensitivity (SN) = 87%, specificity (SP) = 99%), the algorithm used provided comparable results for breast cancer (cut-off 0.18%, SN = 83%, SP = 87%) and colorectal cancer (cut-off = 0.10%, SN = 100%, SP = 90%). Worse performance was observed for lung cancer (cut-off = 0.06%, SN = 63%, SP = 70%) and renal cell carcinoma (cut-off = 0.30%, SN = 75%, SP = 84%). The algorithm did not perform satisfactorily in melanoma (SN = 60%). For most entities, a high negative predictive value (NPV ≥ 87.5%, melanoma 80%) was determined, whereas positive predictive value (PPV) was clinically not applicable. Automatically determined BSI showed good sensitivity and specificity in prostate cancer and various other entities. Particularly, the high NPV encourages applying BSI as a tool for computer-aided diagnostic in various tumor entities.

16.
PLoS One ; 14(5): e0216781, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31091247

RESUMO

AIM: Purpose of this study was to evaluate the association of the spatial heterogeneity (asphericity, ASP) in intra-therapeutic SPECT/ CT imaging of somatostatin receptor (SSR) positive metastatic gastroenteropancreatic neuroendocrine neoplasms (GEP-NEN) for morphological treatment response to peptide receptor radionuclide therapy (PRRT). Secondly, we correlated ASP derived form a pre-therapeutic OctreoScan (ASP[In]) and an intra-therapeutic [177Lu]-SPECT/CT (ASP[Lu]). MATERIALS AND METHODS: Data from first therapy cycle [177Lu-DOTA0-Tyr3]octreotate ([177Lu]-DOTATATE)-PRRT was retrospectively analyzed in 33 patients (m = 20; w = 13; median age, 72 [46-88] years). The evaluation of response to PRRT was performed according to RECIST 1.1 in responding lesions [RL (SD, PR, CR), n = 104] and non-responding lesions [NRL (PD), n = 27]. The association of SSR tumor heterogeneity with morphological response was evaluated by Kruskal-Wallis test and receiver operating characteristic curve (ROC). The optimal threshold for separation (RL vs. NRL) was calculated using the Youden-index. Relationship between pre- and intra-therapeutic ASP was determined with Spearman's rank correlation coefficient (ρ) and Bland-Altman plots. RESULTS: A total of 131 lesions (liver: n = 59, lymph nodes: n = 48, bone: n = 19, pancreas: n = 5) were analyzed. Lesions with higher ASP values showed a significantly poorer response to PRRT (PD, median: 11.3, IQR: 8.5-15.5; SD, median: 3.4, IQR: 2.1-4.5; PR, median 1.7, IQR: 0.9-2.8; CR, median: 0.5, IQR: 0.0-1.3); Kruskal-Wallis, p<0.001). ROC analyses revealed a significant separation between RL and NRL for ASP after 4 months (AUC 0.85, p<0.001) and after 12 months (AUC 0.94, p<0.001). The optimal threshold for ASP was >5.45% (sensitivity 96% and specificity 82%). The correlation coefficient of pre- and intra-therapeutic ASP revealed ρ = 0.72 (p <0.01). The mean absolute difference between ASP[In] and ASP[Lu] was -0.04 (95% Limits of Agreement, -6.1-6.0). CONCLUSION: Pre- and intra-therapeutic ASP shows a strong correlation and might be an useful tool for therapy monitoring.


Assuntos
Neoplasias Gastrointestinais , Proteínas de Neoplasias/metabolismo , Tumores Neuroendócrinos , Octreotida/análogos & derivados , Receptores de Somatostatina/metabolismo , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/metabolismo , Neoplasias Ósseas/mortalidade , Intervalo Livre de Doença , Feminino , Neoplasias Gastrointestinais/diagnóstico por imagem , Neoplasias Gastrointestinais/metabolismo , Neoplasias Gastrointestinais/mortalidade , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/metabolismo , Neoplasias Hepáticas/mortalidade , Metástase Linfática , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/metabolismo , Tumores Neuroendócrinos/mortalidade , Octreotida/administração & dosagem , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida
17.
Acta Radiol Open ; 8(6): 2058460119856266, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31258933

RESUMO

BACKGROUND: Iterative computed tomography (CT) image reconstruction shows high potential for the preservation of image quality in diagnostic CT while reducing patients' exposure; it has become available for low-dose CT (LD-CT) in high-end hybrid imaging systems (e.g. single-photon emission computed tomography [SPECT]-CT). PURPOSE: To examine the effect of an iterative CT reconstruction algorithm on image quality, image noise, detectability, and the reader's confidence for LD-CT data by a subjective assessment. MATERIAL AND METHODS: The LD-CT data were validated for 40 patients examined by an abdominal hybrid SPECT-CT (U = 120 kV, I = 40 mA, pitch = 1.375). LD-CT was reconstructed using either filtered back projection (FBP) or an iterative image reconstruction algorithm (Adaptive Statistical Iterative Reconstruction [ASIR]®) with different parameters (ASIR levels 50% and 100%). The data were validated by two independent blinded readers using a scoring system for image quality, image noise, detectability, and reader confidence, for a predefined set of 16 anatomic substructures. RESULTS: The image quality was significantly improved by iterative reconstruction of the LD-CT data compared with FBP (P ≤ 0.0001). While detectability increased in only 2/16 structures (P ≤ 0.03), the reader's confidence increased significantly due to iterative reconstruction (P ≤ 0.002). Meanwhile, at the ASIR level of 100%, the detectability in bone structure was highly reduced (P = 0.003). CONCLUSION: An ASIR level of 50% represents a good compromise in abdominal LD-CT image reconstruction. The specific ASIR level improved image quality (reduced image noise) and reader confidence, while preserving detectability of bone structure.

18.
Lung Cancer ; 118: 155-160, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29571995

RESUMO

RATIONALE: Pre-operative lobar function is estimated by scintigraphy in patients with pulmonary malignancies and compromised function. This study compared the lobar perfusion determined by scintigraphy (PS) with data from SPECT/low-dose-CT (SPECT/ldCT) analyzed manually and semi-automatic. METHODS: Retrospective analysis on 39 patients (m/f = 25/14; age: 72.5 [22-89] years) with indication for pulmonary perfusion scintigraphy. Imaging was performed using SPECT/ldCT. Data was analyzed manually and by semi-automatic software. Readers' confidence in 3D-segmentation was scored by two independent readers. Interrater agreement was calculated. In addition, Spearman's rank correlation and Wilcoxon's test were used. RESULTS: Results from PS differed significantly from SPECT/ldCT processed manually or semi-automatically in 4/5 lobes (total difference ≤21.6%; rho ≥0.44) and in 3/5 (total difference 21.6%; rho ≥0.37), respectively. Readers' confidence in 3D-segmentation showed a perfect interrater agreement (κ = 0.98). CONCLUSION: Quantification of lobar perfusion by SPECT/ldCT differs significantly from planar scintigraphy (e.g., with potential influence on therapy). The semi-automatic software analysis provides an applicable methodology.


Assuntos
Neoplasias Pulmonares/diagnóstico , Pulmão/fisiologia , Imagem de Perfusão/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Projetos Piloto , Período Pré-Operatório , Testes de Função Respiratória , Estudos Retrospectivos , Adulto Jovem
19.
Health Phys ; 114(1): 58-63, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29049048

RESUMO

In radioembolic therapy (RET) of hepatic malignancies using yttrium-90 (Y)-labeled resin microspheres, radiation protection is primarily concerned with avoiding contamination by radioactive spheres. However, as Y is bound to the microsphere surface by a potentially reversible ion-exchange process, the aim of this study was to assess the extent of the potential excreted activity in urine. After RET with Y-labeled resin-based microspheres, urinary excretion of free Y was prospectively analyzed in 51 interventions (n = 45 patients) by sampling urine over 48 h (two 24-h intervals) consecutively. The measured urinary concentration of Y, normalized to the administered microsphere activity, was a median of 58.5 kBq L GBq (range = 3.5-590.9 kBq L GBq) and 17.8 kBq L GBq (1.8-58.8 kBq L GBq) for the first and second 24-h periods after administration, respectively (p ≤ 0.0001, F = 28.4, result from ANOVA). The total excreted activity significantly decreased (p ≤ 0.0001) from a median of 72.5 kBq in the first 24-h period to a median of 22.1 kBq in the second 24-h period. Urinary excretion of free Y after resin-based RET occurs for a longer period and at a higher activity excretion than previously published, which has to be considered when patients are either hospitalized or return home after RET. Existing approaches for patient hospitalization, especially in temporary radiation protection areas, justified by the previously reported lower excretion rate, should be re-evaluated, and as a consequence, the current product safety information and handling recommendations for Y-labeled resin-based microspheres may need to be revised.


Assuntos
Braquiterapia/métodos , Neoplasias Hepáticas/urina , Microesferas , Proteção Radiológica/métodos , Compostos Radiofarmacêuticos/urina , Radioisótopos de Ítrio/urina , Adulto , Idoso , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Poluentes Radioativos da Água
20.
Cardiovasc Intervent Radiol ; 41(6): 890-897, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29344714

RESUMO

PURPOSE: 3 and 9 o'clock arteries (3&9As) which supply the common hepatic duct connect hepatic with duodenal/pancreatic territories. The study purpose is to describe the angiographic anatomy of 3&9As and discuss their relevance when performing radioembolization (RE) of liver malignancies. MATERIALS AND METHODS: The anatomy of the 3&9As was systematically investigated by a retrospective analysis of angiograms, technetium Tc-99 m-macroaggregated albumin (MAA) scintigrams, yttrium-90 (Y90) Bremsstrahlung-SPECT/CT datasets, and clinical data of 153 patients who underwent RE between 2010 and 2013. RESULTS: Analysis of preprocedural angiograms identified 3&9As in 36 (24%) of the 153 patients. Following embolization of the gastroduodenal artery, 3&9As were seen in 53 cases (35%). The three most common origins of the 3&9As were the right hepatic artery (n = 14), the cystic artery (n = 11), and S5 and S6 segmental arteries (n = 5 each). Extrahepatic Tc-99 m-MAA deposition in the territory of the 3&9As was significantly more frequent when 3&9As were detectable on preprocedural angiograms (28%visible vs. 11%not visible; p = 0.001) and especially when the 3&9As were not embolized or bridged prior to RE (50%not occluded/bridged vs. 19%occupied/bridged; p = 0.043). The presence of extrahepatic Y90 Bremsstrahlung after RE (n = 17) was attributable to microsphere diversion via the 3&9A territory in four patients and possible diversion via this territory in nine patients. Five of these 13 patients presented with epigastric pain, nausea, or vomiting (CTCAE severity grade ≤ 3) (p = 0.014). CONCLUSION: 3&9As are commonly detectable during evaluation angiography prior to RE, have a variable angioanatomic origin, and should be prophylactically occluded to prevent complications.


Assuntos
Braquiterapia/métodos , Neoplasias Hepáticas/radioterapia , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia/métodos , Feminino , Artéria Hepática/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA