Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 48(4): 577-587, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38438332

RESUMO

ABSTRACT: The incidence of neuroendocrine neoplasms (NENs) has gradually increased over the past few decades with the majority of patients presenting with metastases on initial presentation. The liver is the most common site of initial metastatic disease, and the presence of liver metastasis is an independent prognostic factor associated with a negative outcome. Because NENs are heterogenous neoplasms with variable differentiation, grading, and risk of grade transformation over time, accurate diagnosis and management of neuroendocrine liver lesions are both important and challenging. This is particularly so with the multiple liver-directed treatment options available. In this review article, we discuss the diagnosis, treatment, and response evaluation of NEN liver metastases.


Assuntos
Neoplasias Hepáticas , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Intestinais/diagnóstico por imagem , Fígado/diagnóstico por imagem , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia
2.
Radiology ; 303(1): 90-98, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35014900

RESUMO

Background Assessment of liver lesions is constrained as CT radiation doses are lowered; evidence suggests deep learning reconstructions mitigate such effects. Purpose To evaluate liver metastases and image quality between reduced-dose deep learning image reconstruction (DLIR) and standard-dose filtered back projection (FBP) contrast-enhanced abdominal CT. Materials and Methods In this prospective Health Insurance Portability and Accountability Act-compliant study (September 2019 through April 2021), participants with biopsy-proven colorectal cancer and liver metastases at baseline CT underwent standard-dose and reduced-dose portal venous abdominal CT in the same breath hold. Three radiologists detected and characterized lesions at standard-dose FBP and reduced-dose DLIR, reported confidence, and scored image quality. Contrast-to-noise ratios for liver metastases were recorded. Summary statistics were reported, and a generalized linear mixed model was used. Results Fifty-one participants (mean age ± standard deviation, 57 years ± 13; 31 men) were evaluated. The mean volume CT dose index was 65.1% lower with reduced-dose CT (12.2 mGy) than with standard-dose CT (34.9 mGy). A total of 161 lesions (127 metastases, 34 benign lesions) with a mean size of 0.7 cm ± 0.3 were identified. Subjective image quality of reduced-dose DLIR was superior to that of standard-dose FBP (P < .001). The mean contrast-to-noise ratio for liver metastases of reduced-dose DLIR (3.9 ± 1.7) was higher than that of standard-dose FBP (3.5 ± 1.4) (P < .001). Differences in detection were identified only for lesions 0.5 cm or smaller: 63 of 65 lesions detected with standard-dose FBP (96.9%; 95% CI: 89.3, 99.6) and 47 lesions with reduced-dose DLIR (72.3%; 95% CI: 59.8, 82.7). Lesion accuracy with standard-dose FBP and reduced-dose DLIR was 80.1% (95% CI: 73.1, 86.0; 129 of 161 lesions) and 67.1% (95% CI: 59.3, 74.3; 108 of 161 lesions), respectively (P = .01). Lower lesion confidence was reported with a reduced dose (P < .001). Conclusion Deep learning image reconstruction (DLIR) improved CT image quality at 65% radiation dose reduction while preserving detection of liver lesions larger than 0.5 cm. Reduced-dose DLIR demonstrated overall inferior characterization of liver lesions and reader confidence. Clinical trial registration no. NCT03151564 © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Algoritmos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
3.
J Comput Assist Tomogr ; 46(3): 333-343, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35575649

RESUMO

BACKGROUND: Routine computed tomography (CT) scans are thought to have poor performance for detection of gastrointestinal (GI) neuroendocrine neoplasms (NENs), which leads to delayed workup. Detection of even 1 bowel tumor can guide diagnostic workup and management. The purposes of this study were to assess the accuracy of multidetector computed tomography (MDCT) and to compare negative versus positive enteric contrast in detecting at least 1 GI tumor per patient with suspected or confirmed diagnosis of a NEN. METHODS: This retrospective study included 107 patients with intravenous and oral contrast (65 positive, 40 negative, and 2 no oral contrast) abdominopelvic MDCT. Two abdominal radiologists independently analyzed the CTs for detection and localization of bowel NENs. Surgical pathology was considered the reference standard. Analyses included κ and summary statistics, McNemar test, Pearson χ2 test, and Fisher exact test. RESULTS: Among the 107 CT scans, there were 30 pathology negative studies and 77 studies with positive pathology for GI NEN. Interreader agreement for CT evaluation was substantial (κ = 0.61). At least 1 GI NEN per patient was detected with 51% to 53% sensitivity, 87% to 93% specificity, 91% to 95% positive predictive value (PPV), 42% negative predictive value, and 63% accuracy for each reader, and 57% accuracy when only the concordant (ie, matching) results of the 2 readers were considered. Computed tomography scans with negative enteric contrast had significantly higher sensitivity for concordant results than CTs with positive enteric contrast (58% vs 30%, P = 0.01). Specificity (100% vs 95%, P = 0.5), PPV (100% vs 93%, P = 0.49), negative predictive value (39% vs 39%, P = 0.99), and accuracy (67% vs 51%, P = 0.10) were not significantly different for negative versus positive enteric contrast for the concordant results. There was no significant difference in GI NEN localization between the readers. CONCLUSIONS: Routine MDCT with either positive or negative enteric contrast can detect at least 1 GI tumor per patient with more than 90% PPV and more than 50% accuracy in patients suspected of GI NEN. Using negative enteric contrast improves sensitivity for GI NEN versus positive enteric contrast. In addition, there is high accuracy in localizing the bowel tumor with positive or negative enteric contrast, which may guide surgery. Radiologists should have heightened awareness that evaluating such scans closely may lead to detection of primary bowel NENs at a higher rate than previously reported.


Assuntos
Tomografia Computadorizada Multidetectores , Tumores Neuroendócrinos , Meios de Contraste , Humanos , Intestino Delgado/patologia , Tomografia Computadorizada Multidetectores/métodos , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Radiology ; 290(2): 400-409, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30480489

RESUMO

Purpose To evaluate colorectal cancer hepatic metastasis detection and characterization between reduced radiation dose (RD) and standard dose (SD) contrast material-enhanced CT of the abdomen and to qualitatively compare between filtered back projection (FBP) and iterative reconstruction algorithms. Materials and Methods In this prospective study (from May 2017 through November 2017), 52 adults with biopsy-proven colorectal cancer and suspected hepatic metastases at baseline CT underwent two portal venous phase CT scans: SD and RD in the same breath hold. Three radiologists, blinded to examination details, performed detection and characterization of 2-15-mm lesions on the SD FBP and RD adaptive statistical iterative reconstruction (ASIR)-V 60% series images. Readers assessed overall image quality and lesions between SD FBP and seven different iterative reconstructions. Two nonblinded consensus reviewers established the reference standard using the picture archiving and communication system lesion marks of each reader, multiple comparison examinations, and clinical data. Results RD CT resulted in a mean dose reduction of 54% compared with SD. Of the 260 lesions (233 metastatic, 27 benign), 212 (82%; 95% confidence interval [CI]: 76%, 86%) were detected with RD CT, whereas 252 (97%; 95% CI: 94%, 99%) were detected with SD (P < .001); per-lesion sensitivity was 79% (95% CI: 74%, 84%) and 94% (95% CI: 90%, 96%) (P < .001), respectively. Mean qualitative scores ranked SD images as higher quality than RD series images, and ASIR-V ranked higher than ASIR and Veo 3.0. Conclusion CT evaluation of colorectal liver metastases is compromised with modest radiation dose reduction, and the use of iterative reconstructions could not maintain observer performance. © RSNA, 2018.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Adulto Jovem
5.
J Comput Assist Tomogr ; 43(1): 155-162, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30211799

RESUMO

OBJECTIVE: This study aimed to evaluate the quality of enhancement and solid-organ lesion depiction using weight-based intravenous (IV) contrast dosing calculated by injector software versus fixed IV contrast dose in oncologic abdominal computed tomographic (CT) examinations. METHODS: This institutional review board-exempt retrospective cohort study included 134 patients who underwent single-phase abdominal CT before and after implementation of weight-based IV contrast injector software. Patient weight, height, body mass index, and body surface area were determined. Two radiologists qualitatively assessed examinations (4 indicating markedly superior to -4 indicating markedly inferior), and Hounsfield unit measurements were performed. RESULTS: Enhancement (estimated mean, -0.05; 95% confidence interval [CI], -0.19 to 0.09; P = 0.46) and lesion depiction (estimated mean, -0.01; 95% CI, -0.10 to 0.07; P = 0.79) scores did not differ between CT examinations using weight-based IV contrast versus fixed IV contrast dosing when a minimum of 38.5 g of iodine was used. However, the scores using weight-based IV contrast dosing were lower when the injector software calculated and delivered less than 38.5 g of iodine (estimated mean, -0.81; 95% CI, -1.06 to -0.56; P < 0.0001). There were no significant differences in measured Hounsfield units between the CT examinations using weight-based IV contrast dosing versus fixed IV contrast dosing. CONCLUSIONS: Oncologic CT image quality was maintained or improved with weight-based IV contrast dosing using injector software when using a minimum amount of 38.5 g of iodine.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Peso Corporal , Meios de Contraste/administração & dosagem , Neoplasias/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Atenção Terciária à Saúde , Adulto Jovem
6.
Trop Anim Health Prod ; 51(4): 859-866, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30617724

RESUMO

Murrah buffalo heifers (live weight 135 ± 17 kg) were fed a total mixed ration without supplementation (CON), or supplemented with sodium monensin (MON; Rumensin® 200, Elanco Animal Health, Brazil) @ 0.6 mg/kg of body weight for 90 days. Nutrient digestibility and nitrogen retention were estimated during the mid-experiment, and enteric methane production was measured by sulphur hexafluoride tracer technique for consecutive-5 days after the digestion trial. The dry matter (DM) and nutrient intake were not affected but DM intake expressed as percent of body weight was decreased by monensin supplementation (3 vs 2.7% for CON and MON, respectively). The crude protein digestibility was higher for MON whereas, digestibility of other nutrients was not affected. Nitrogen retention (+ 4.59 g/day) and daily body weight gain (+ 56 g/day) were greater for MON-fed heifers without any significant effect on nitrogen intake and nitrogen excretion through faeces and urine. Daily enteric methane production was reduced by 12.61% but the treatments did not differ significantly. Methane emission expressed as gram per unit of DM, organic matter and digestible DM intake was lower for MON than CON and methane conversion rate (Ym) % of GE and ME intake was also decreased by 8-9%. On day 60, blood glucose level was increased and urea nitrogen was decreased in MON-fed heifers. This study indicated that monensin supplementation at 0.6 mg/kg body weight in growing heifers improved daily gain and feed efficiency while it reduced enteric methane production which can reduce feedlot time and consequent life time CH4 production.


Assuntos
Antiprotozoários , Búfalos , Digestão , Metano , Monensin , Animais , Bovinos , Feminino , Ração Animal/análise , Antiprotozoários/farmacologia , Dieta/veterinária , Suplementos Nutricionais , Digestão/efeitos dos fármacos , Ingestão de Energia , Fezes , Metano/metabolismo , Monensin/farmacologia , Nitrogênio/metabolismo , Nutrientes , Aumento de Peso
7.
Radiographics ; 38(2): 483-499, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29528821

RESUMO

Lynch syndrome is the most common hereditary cancer syndrome, the most common cause of heritable colorectal cancer, and the only known heritable cause of endometrial cancer. Other cancers associated with Lynch syndrome include cancers of the ovary, stomach, urothelial tract, and small bowel, and less frequently, cancers of the brain, biliary tract, pancreas, and prostate. The oncogenic tendency of Lynch syndrome stems from a set of genomic alterations of mismatch repair proteins. Defunct mismatch repair proteins cause unusually high instability of regions of the genome called microsatellites. Over time, the accumulation of mutations in microsatellites and elsewhere in the genome can affect the production of important cellular proteins, spurring tumorigenesis. Universal testing of colorectal tumors for microsatellite instability (MSI) is now recommended to (a) prevent cases of Lynch syndrome being missed owing to the use of clinical criteria alone, (b) reduce morbidity and mortality among the relatives of affected individuals, and (c) guide management decisions. Organ-specific cancer risks and associated screening paradigms vary according to the sex of the affected individual and the type of germline DNA alteration causing the MSI. Furthermore, Lynch syndrome-associated cancers have different pathologic, radiologic, and clinical features compared with their sporadic counterparts. Most notably, Lynch syndrome-associated tumors tend to be more indolent than non-Lynch syndrome-associated neoplasms and thus may respond differently to traditional chemotherapy regimens. The high MSI in cases of colorectal cancer reflects a difference in the biologic features of the tumor, possibly with a unique susceptibility to immunotherapy. ©RSNA, 2018.


Assuntos
Neoplasias Colorretais Hereditárias sem Polipose/diagnóstico por imagem , Neoplasias Colorretais Hereditárias sem Polipose/genética , Genômica , Neoplasias Colorretais Hereditárias sem Polipose/patologia , Neoplasias Colorretais Hereditárias sem Polipose/terapia , Diagnóstico Diferencial , Humanos , Programas de Rastreamento , Instabilidade de Microssatélites
8.
J Comput Assist Tomogr ; 42(2): 184-190, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28806318

RESUMO

OBJECTIVE: The purpose of this study was to compare abdominopelvic computed tomography images reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) with model-based iterative reconstruction (Veo 3.0), ASIR, and filtered back projection (FBP). METHODS AND MATERIALS: Abdominopelvic computed tomography scans for 36 patients (26 males and 10 females) were reconstructed using FBP, ASIR (80%), Veo 3.0, and ASIR-V (30%, 60%, 90%). Mean ± SD patient age was 32 ± 10 years with mean ± SD body mass index of 26.9 ± 4.4 kg/m. Images were reviewed by 2 independent readers in a blinded, randomized fashion. Hounsfield unit, noise, and contrast-to-noise ratio (CNR) values were calculated for each reconstruction algorithm for further comparison. Phantom evaluation of low-contrast detectability (LCD) and high-contrast resolution was performed. RESULTS: Adaptive statistical iterative reconstruction-V 30%, ASIR-V 60%, and ASIR 80% were generally superior qualitatively compared with ASIR-V 90%, Veo 3.0, and FBP (P < 0.05). Adaptive statistical iterative reconstruction-V 90% showed superior LCD and had the highest CNR in the liver, aorta, and, pancreas, measuring 7.32 ± 3.22, 11.60 ± 4.25, and 4.60 ± 2.31, respectively, compared with the next best series of ASIR-V 60% with respective CNR values of 5.54 ± 2.39, 8.78 ± 3.15, and 3.49 ± 1.77 (P <0.0001). Veo 3.0 and ASIR 80% had the best and worst spatial resolution, respectively. CONCLUSIONS: Adaptive statistical iterative reconstruction-V 30% and ASIR-V 60% provided the best combination of qualitative and quantitative performance. Adaptive statistical iterative reconstruction 80% was equivalent qualitatively, but demonstrated inferior spatial resolution and LCD.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
9.
Am J Dermatopathol ; 40(11): 831-835, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29863571

RESUMO

Myeloid sarcoma is a rare extramedullary hematologic malignancy. Accurate and timely diagnosis may be challenging because myeloid sarcoma is known to mimic solid tumors, including hepatobiliary, nasopharyngeal, and breast carcinomas. We report a case of myeloid sarcoma that developed in the primary tumor lymphatic drainage field of a previously treated intermediate-thickness cutaneous melanoma, clinically and radiographically mimicking an in-transit metastasis, in a patient with myelodysplastic syndrome. The diagnosis of myeloid sarcoma was achieved after surgical excision of the mass and pathological examination that included extensive immunohistochemical studies. Awareness of such an unusual clinical presentation can help reduce diagnostic delay and ensure that adequate tissue is obtained for pathological examination and ancillary studies that are critical for accurate diagnosis and appropriate patient management.


Assuntos
Melanoma/patologia , Segunda Neoplasia Primária/diagnóstico , Sarcoma Mieloide/diagnóstico , Neoplasias Cutâneas/patologia , Idoso , Diagnóstico Diferencial , Humanos , Masculino , Melanoma/radioterapia , Síndromes Mielodisplásicas/etiologia , Metástase Neoplásica/diagnóstico , Neoplasias Induzidas por Radiação/patologia , Neoplasias Cutâneas/radioterapia , Melanoma Maligno Cutâneo
10.
AJR Am J Roentgenol ; 209(6): 1278-1284, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29064751

RESUMO

OBJECTIVE: The purpose of this study is to compare the prognostic value of various solid tumor response criteria as well as the additive value of clinical risk factors in patients with advanced renal cell carcinoma (RCC). MATERIALS AND METHODS: Two sets of CT scans (pretreatment scans and scans obtained 1-3.5 months after treatment) were reviewed for 57 patients with metastatic RCC treated with pazopanib in the salvage setting. Tumor response on the posttherapy scan was evaluated using Response Evaluation Criteria in Solid Tumors (RECIST) and Choi, modified Choi (mChoi), MASS (Morphology, Attenuation, Size, and Structure), and 10% threshold criteria. In addition, combined Memorial Sloan-Kettering Cancer Center (MSKCC) risk factors plus imaging criteria were used to define response groups. Response evaluations using these criteria were correlated with overall survival (OS) and progression-free survival (PFS), with use of the log-rank test. RESULTS: Patients classified as having progressive disease (PD) on the basis of RECIST, mChoi, and MASS criteria had a significantly worse OS than patients with stable disease (SD) and partial response (PR). With the addition of MSKCC risk factors, all groups with PD defined by combined criteria had significantly worse OS. For 37 patients with no or one MSKCC risk factor, response groups defined by Choi, mChoi, MASS, and 10% threshold criteria did not differ in PFS or OS. However, among 20 patients with two to three MSKCC risk factors, those classified as having PR had longer PFS than did those with SD and had longer OS than did those with PD. CONCLUSION: For patients with advanced RCC for which prior therapies have failed, the prognostic value of various imaging-based tumor response criteria differs on the basis of the MSKCC clinical risk status.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/tratamento farmacológico , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/tratamento farmacológico , Pirimidinas/uso terapêutico , Terapia de Salvação , Sulfonamidas/uso terapêutico , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Carcinoma de Células Renais/patologia , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Indazóis , Neoplasias Renais/patologia , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Prognóstico , Critérios de Avaliação de Resposta em Tumores Sólidos , Estudos Retrospectivos , Fatores de Risco
11.
AJR Am J Roentgenol ; 209(6): 1291-1296, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28981362

RESUMO

OBJECTIVE: Birt-Hogg-Dubé (BHD) syndrome is an autosomal dominant inherited syndrome involving multiple organs. In young patients, renal neoplasms that are multiple, bilateral, or both, such as oncocytomas, chromophobe renal cell carcinoma (RCC), hybrid chromophobe RCC-oncocytomas, clear cell RCC, and papillary RCC, can suggest BHD syndrome. Extrarenal findings, including dermal lesions, pulmonary cysts, and spontaneous pneumothoraces, also aid in diagnosis. CONCLUSION: Radiologists may be one of the first medical specialists to suggest the diagnosis of BHD syndrome. Knowledge of pathogenesis and management, including the importance of the types of renal neoplasms in a given patient, is needed to properly recognize this rare condition.


Assuntos
Síndrome de Birt-Hogg-Dubé/diagnóstico por imagem , Meios de Contraste , Diagnóstico Diferencial , Humanos
12.
AJR Am J Roentgenol ; 204(5): 1031-41, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25905938

RESUMO

OBJECTIVE: The purpose of this article is to discuss the histopathologic features, genetics, clinical presentation, and imaging of hereditary renal cancer syndromes. CONCLUSION: Hereditary renal cell carcinoma syndromes can be diagnosed with a pattern-based approach focused on the predominant histologic renal cell carcinoma subtype and associated renal and extrarenal features of each syndrome.


Assuntos
Carcinoma de Células Renais/diagnóstico , Carcinoma de Células Renais/genética , Diagnóstico por Imagem , Neoplasias Renais/diagnóstico , Neoplasias Renais/genética , Síndromes Neoplásicas Hereditárias/diagnóstico , Síndromes Neoplásicas Hereditárias/genética , Humanos , Mutação
13.
J Comput Assist Tomogr ; 39(2): 263-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25635931

RESUMO

OBJECTIVE: Three-dimensional T1-weighted (T1W) gradient recall echo volumetric interpolated breath-hold examination (VIBE) using generalized autocalibrating partially parallel acquisitions (GRAPPA) is one of the key sequences in liver magnetic resonance imaging (MRI) and is used for precontrast, dynamic postcontrast, and delayed postcontrast imaging. The purpose of this study is to compare image quality and liver lesion detection (LLD) on a shorter-duration T1W VIBE sequence using the controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) technique with the conventional T1W GRAPPA-VIBE sequence during a single liver MRI session on a 1.5-T Seimens scanner. METHODS: Twenty consecutive patients (9 women and 11 men; age range, 36-85 years) were included in this prospective study. All patients underwent a complete liver MRI on a 1.5-T magnet (Aera; Siemens Medical Systems, Erlangen, Germany) that consisted of a T1W (in/out-of-phase), T2W, DWI, and precontrast and postcontrast multiphasic images (late arterial, 50 seconds, 120 seconds, and 300 seconds) with GRAPPA-VIBE. The CAIPI-VIBE images were acquired for precontrast and at 300 seconds (5 minutes) postcontrast phases (6.9 seconds per phase) in addition to GRAPPA-VIBE (21 seconds per phase). The shorter time for the CAIPI-VIBE was selected to allow postprocessing of image acquisition in the setting of multi-late arterial phase (single breath hold) postcontrast images. Five radiologists independently analyzed image quality with predefined scores for liver edge sharpness, artifacts, fat saturation deficiency, visualization of the portal veins and hepatic veins, and LLD (size, <0.5-3.8 cm). Score 0 was suboptimal (inadequate), 1 was acceptable for diagnosis, and 2 was optimal (excellent). Kappa statistics were used to assess agreement among readers. Generalized linear mixed model with generalized estimation equation method was used to estimate and compare the LLD failure rates. RESULTS: No statistically significant difference was seen in the degree of reader variability between CAIPI-VIBE and GRAPPA-VIBE for all evaluated categories using multirater κ statistics. For the precontrast and 5-minutepostcontrast phase sequences, greater than 95% of images were considered to be of acceptable quality in all image quality categories for both sequences. Forty-one lesions were evaluated in 17 patients with total of 204 observations (n = 204) by 5 readers. For 5-minute postcontrast images, the LLD rate of CAIPI-VIBE (80%) was lower than GRAPPA-VIBE (84%) (P = 0.03) for small lesions (0.5-1.7 cm). There was no significant difference in lesion detection on precontrast images. CONCLUSIONS: At 1.5 T, the CAIPI-VIBE may be helpful in reducing scan time and demonstrates similar image quality compared with the traditional GRAPPA-VIBE. The CAIPI-VIBE has shorter breath-hold time requirement and thus can be an acceptable alternative for the precontrast and 5-minute postcontrast GRAPPA-VIBE in patients with breath-hold difficulties.


Assuntos
Aumento da Imagem , Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
Angew Chem Int Ed Engl ; 54(33): 9654-8, 2015 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-26118973

RESUMO

The lack of high-efficient, low-cost, and durable bifunctional electrocatalysts that act simultaneously for the oxygen reduction reaction (ORR) and the oxygen evolution reaction (OER) is currently one of the major obstacles to commercializing the electrical rechargeability of zinc-air batteries. A nanocomposite CoO-NiO-NiCo bifunctional electrocatalyst supported by nitrogen-doped multiwall carbon nanotubes (NCNT/CoO-NiO-NiCo) exhibits excellent activity and stability for the ORR/OER in alkaline media. More importantly, real air cathodes made from the bifunctional NCNT/CoO-NiO-NiCo catalysts further demonstrated superior performance to state-of-the-art Pt/C or Pt/C+IrO2 catalysts in primary and rechargeable zinc-air batteries.

15.
Abdom Imaging ; 39(1): 66-85, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24077815

RESUMO

Renal cell carcinoma is the most common malignant renal tumor in the adults. Significant advances have been made in the management of localized and advanced renal cell carcinoma. Surgery is the standard of care and accurate pre-operative staging based on imaging is critical in guiding appropriate patient management. Besides staging, imaging plays a key role in the post-operative surveillance and evaluation of response to systemic therapies. Both CT and MR are useful in the staging and follow up of renal cell carcinoma, but CT is more commonly used due to its lower costs and wider availability. In this article, we discuss and illustrate the role of multi-detector CT in pre-operative staging, post-operative surveillance, and evaluation of response to systemic therapy in renal cell carcinoma.


Assuntos
Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia Computadorizada Multidetectores , Carcinoma de Células Renais/cirurgia , Humanos , Neoplasias Renais/cirurgia , Neoplasias Renais/terapia , Invasividade Neoplásica , Estadiamento de Neoplasias , Nefrectomia , Vigilância da População , Veias Renais/patologia , Sensibilidade e Especificidade , Resultado do Tratamento , Veia Cava Inferior/patologia
16.
Curr Probl Cardiol ; 49(3): 102217, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38013011

RESUMO

BACKGROUND: Pre-eclampsia and eclampsia are common causes of morbidity and mortality, especially in low-income countries. Reducing adverse outcomes associated with hypertensive disorders of pregnancy has been the ultimate priority in recent years. We aim to evaluate the association between calcium supplementation and preeclampsia and gestational hypertension risk among pregnant women. METHODS: A systematic literature search was performed in electronic databases from inception to 15th July 2023, including only randomized controlled trials. Odds ratio (OR) were, and their corresponding 95% confidence interval (95% CI). RESULTS: A total of 26 studies with 20,038 patients (10,003 patients with calcium supplements and 10,035 patients with placebo group) were included in the analysis. The Pooled analysis of primary outcome shows that calcium supplements reduce the risk of preeclampsia by 49% (OR, 0.51(95%CI: 0.40-0.66), P<0.001), and reduce the risk of gestational hypertension by 30% (OR, 0.70 (95%CI: 0.58-0.85)), P<0.001) compared to placebo. There was a trend of lower incidence of preterm delivery (OR, 0.88 (95%CI: 0.71-1.09), P=0.23), labor induction (OR, 0.90 (95%CI: 0.78-1.03), P=0.13), small for gestational age (OR, 0.70 (95% CI:0.37-1.32), P = 0.27), low birth weight (OR, 0.96 (95%CI: 0.86-1.08), P=0.53), perinatal mortality (OR, 0.88 (95%CI: 0.72-1.09), P=0.24), and maternal mortality (OR, 0.48 (95%CI: 0.12-1.84), P=0.28) among calcium supplementation group compared with the placebo group, however, statistical signifance was not achieved. CONCLUSION: This study shows that calcium supplements are associated with a significant reduction in the risk of preeclampsia and gestational hypertension and a trend toward better maternal and fetal-related outcomes.


Assuntos
Hipertensão Induzida pela Gravidez , Pré-Eclâmpsia , Recém-Nascido , Gravidez , Feminino , Humanos , Pré-Eclâmpsia/epidemiologia , Pré-Eclâmpsia/prevenção & controle , Hipertensão Induzida pela Gravidez/epidemiologia , Hipertensão Induzida pela Gravidez/prevenção & controle , Cálcio , Suplementos Nutricionais , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Curr Probl Cardiol ; 49(3): 102338, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38103817

RESUMO

BACKGROUND: Post-stroke depression (PSD) is a prevalent neuropsychiatric sequelae following stroke, often associated with diminished functional recovery and heightened mortality risk. Emerging evidence suggests neuroinflammation, triggered in response to stroke events, may be instrumental in precipitating PSD. AIM: This study aims to assess the significance of high-sensitivity C-reactive protein (Hs-CRP) and homocysteine (Hcy) in post-stroke individuals with PSD. METHODS: We systematically searched all electronic databases from inception until May 30, 2023. Outcomes were reported as standard mean difference (SMD), and their corresponding 95% confidence interval (95% CI). RESULTS: A total of 12 studies with 3,230 patients were included in this study. The mean age of the overall cohort was 65.7 years, and patients with PSD were observed to be older than patients without PSD (68.3 years versus 63.1 years). We observed a higher female prevalence in the PSD group (44.4% versus 40.7%). PSD patients were more likely to be widowed (19.4% versus 8.4%) and more likely to have a family history of psychiatric disorder (11.3% versus 4.9%) compared to non-PSD patients. We also observed that patients with PSD had higher levels of baseline Hs-CRP [SMD 0.16, (95% CI 0.08 to 0.25), p<0.001], and Hcy [SMD 0.14, (95% CI 0.05 to 0.22), p<0.001] than patients without PSD. Meta-regression analysis did not reveal any effect modifier for higher Hs-CRP in the study group, however, history of widowhood was a significant effect modifier when assessing Hcy levels between the two groups (coefficient 1.998, p=0.038). CONCLUSION: Baseline levels of Hs-CRP and Hcy were significantly higher in patients with PSD, highlighting the role of recognizing demographic and biochemical markers in understanding the complexities of post-stroke depression.


Assuntos
Proteína C-Reativa , Acidente Vascular Cerebral , Humanos , Feminino , Idoso , Proteína C-Reativa/metabolismo , Depressão/epidemiologia , Depressão/etiologia , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/psicologia , Biomarcadores , Progressão da Doença
18.
Pediatr Neurol ; 161: 43-54, 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39265434

RESUMO

BACKGROUND: Cerebral palsy (CP) is a neurological disorder that impairs motor abilities. Identifying maternal biomarker derangements can facilitate further evaluation for early diagnosis, potentially leading to improved clinical outcomes. This study investigates the association between maternal biomarker derangements and CP development during the antenatal period. METHODS: A systematic search was conducted in MEDLINE, EMBASE, and Cochrane databases, following MOOSE guidelines. Data on participants exceeding biomarker thresholds (95th and 5th percentiles) were extracted for combined odds ratio estimation. Geometric mean differences, reported as multiples of the median (MoMs), were used to analyze changes in marker levels. Trimesterwise subgroup analysis and metaregression assessed the impact of variables on outcomes. RESULTS: Five observational studies (1552 cases, 484,985 controls) revealed lower maternal pregnancy-associated plasma protein A levels were associated with CP (pooled odds ratio [OR] = 1.60, 95% confidence interval [CI] = 1.22 to 2.09; I = 0%), with a -0.04 MoM geometric mean difference. Lower maternal beta-human chorionic gonadotropin (HCG) levels in first and second trimesters indicated a pooled OR = 1.18 (95% CI = 0.85 to 1.63; I = 57%). Sensitivity analysis showed an OR = 1.40 (95% CI = 1.08 to 1.82; I = 0%), with a -0.07 MoM geometric mean difference. Metaregression identified primigravida status as negatively influencing beta-HCG levels. Elevated nuchal translucency values and CP presented a pooled OR = 1.06 (95% CI = 0.77 to 1.44; I = 0%). CONCLUSION: Lower maternal pregnancy-associated plasma protein A levels during the first trimester and lower beta-HCG levels in the first and second trimesters are associated with CP development in children. Future research should validate the predictive utility of these biomarkers and explore novel ones through large-scale cohort studies.

19.
Eur J Radiol ; 168: 111121, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37806195

RESUMO

PURPOSE: To assess whether image quality differences between SECT (single-energy CT) and DECT (dual-energy CT 70 keV) with equivalent radiation doses result in altered detection and characterization accuracy of liver metastases when using deep learning image reconstruction (DLIR), and whether DECT spectral curve usage improves accuracy of indeterminate lesion characterization. METHODS: In this prospective Health Insurance Portability and Accountability Act-compliant study (March through August 2022), adult men and non-pregnant adult women with biopsy-proven colorectal cancer and liver metastases underwent SECT (120 kVp) and a DECT (70 keV) portovenous abdominal CT scan using DLIR in the same breath-hold (Revolution CT ES; GE Healthcare). Participants were excluded if consent could not be obtained, if there were nonequivalent radiation doses between the two scans, or if the examination was cancelled/rescheduled. Three radiologists independently performed lesion detection and characterization during two separate sessions (SECT DLIRmedium and DECT DLIRhigh) as well as reported lesion confidence and overall image quality. Hounsfield units were measured. Spectral HU curves were provided for any lesions rated as indeterminate. McNemar's test was used to test the marginal homogeneity in terms of diagnostic sensitivity, accuracy and lesion detection. A generalized estimating equation method was used for categorical outcomes. RESULTS: 30 participants (mean age, 58 years ± 11, 21 men) were evaluated. Mean CTDIvol was 34 mGy for both scans. 141 lesions (124 metastases, 17 benign) with a mean size of 0.8 cm ± 0.3 cm were identified. High scores for image quality (scores of 4 or 5) were not significantly different between DECT (N = 71 out of 90 total scores from the three readers) and SECT (N = 62) (OR, 2.01; 95% CI:0.89, 4.57; P = 0.093). Equivalent image noise to SECT DLIRmed (HU SD 10 ± 2) was obtained with DECT DLIRhigh (HU SD 10 ± 3) (P = 1). There was no significant difference in lesion detection between DECT and SECT (140/141 lesions) (99.3%; 95% CI:96.1%, 100%).The mean lesion confidence scores by each reader were 4.2 ± 1.3, 3.9 ± 1.0, and 4.8 ± 0.8 for SECT and 4.1 ± 1.4, 4.0 ± 1.0, and 4.7 ± 0.8 for DECT (odds ratio [OR], 0.83; 95% CI: 0.62, 1.11; P = 0.21). Small lesion (≤5mm) characterization accuracy on SECT and DECT was 89.1% (95% CI:76.4%, 96.4%; 41/46) and 84.8% (71.1%, 93.7%; 39/46), respectively (P = 0.41). Use of spectral HU lesion curves resulted in 34 correct changes in characterizations and no mischaracterizations. CONCLUSION: DECT required a higher strength of DLIR to obtain equivalent noise compared to SECT DLIR. At equivalent radiation doses and image noise, there was no significant difference in subjective image quality or observer lesion performance between DECT (70 keV) and SECT. However, DECT spectral HU curves of indeterminate lesions improved characterization.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Abdome , Estudos Prospectivos , Doses de Radiação
20.
Cureus ; 15(5): e39771, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37398719

RESUMO

Chronic respiratory insufficiency can result from respiratory infections like pneumonia, which can permanently harm the lungs and respiratory system. A 21-year-old female patient arrived at our emergency medicine department (ED) complaining of acute lower-limb pain that worsened when she walked. She also reported feeling weak and having an acute, undiagnosed fever that was resolved by taking medicine two days after the day of admission. She was found to have a body temperature of 99.4°F, decreased air entry on the left side of the chest, and diminished bilateral plantar responsiveness. With the exception of a low calcium level and an increased liver function test, her biochemical indicators were normal. The left lung's basal region had fibrosis, and the right lung's hyperplasia served as a compensatory mechanism, according to the chest radiograph and CT scan of the thorax. The patient underwent treatment with intravenous pantoprazole, ondansetron, ceftriaxone, multivitamin supplementation, gabapentin, and tablets of amitriptyline. On Day 7, her lower limb pain had significantly recovered. After an eight-day hospital stay, she was discharged with instructions to follow up with the pulmonary medicine outpatient department (OPD) and the neurology OPD. A well-known occurrence known as compensatory hyperinflation of the lung happens when one lung is severely injured or rendered inoperable, leading the other lung to enlarge to make up for the loss of respiratory function. This case demonstrates the ability of the respiratory system to compensate for significant damage to one of the lungs.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA