Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 261(6): 1553-1562, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36512088

RESUMO

PURPOSE: To assess study design and a range of anatomical and functional changes after internal limiting membrane (ILM) peeling using forceps developed for atraumatic ILM pick-up compared to standard forceps. METHODS: We conducted a masked proof-of concept randomised controlled trial (RCT) on 65 patients who underwent ILM peeling for idiopathic full-thickness macular hole (FTMH) using etched-tip forceps (etched-tip group, 33 eyes) compared to standard ILM forceps (smooth-tip group, 32 eyes). Patients were assessed preoperatively, 3 weeks, 3 and 6 months postoperatively. RESULTS: The primary closure rate was 95.4%. There was no statistically significant difference between the groups in terms of final visual acuity (66.9 vs 70.9 ETDRS letters, p = 0.13), difference of visual field mean deviation (1.32 vs 1.14 decibels), and number of eyes with pick-up-related retinal haemorrhages (16% vs 16%, p = 0.96), swelling of arcuate nerve fibre layer lesions (63% vs 55%, p = 0.54), number of dissociated optic nerve fibre layer lesions (31.4 vs 41.0, p = 0.16), nor inner retina defects (37% vs 22%, p = 0.17). Similar changes in inner retinal volumes were detected in all 9 sectors of an ETDRS grid except for a trend (p = 0.06) towards a lower reduction in the inferior inner sector in the etched-tip group. CONCLUSIONS: The study was successfully completed with masking maintained and a low risk of bias. Multiple endpoints relating to ILM peeling were assessed, and estimates were provided that can be used for future studies. Although the study was not powered to assess any specific endpoint, the anatomical and functional outcomes assessed did not significantly differ.


Assuntos
Membrana Epirretiniana , Perfurações Retinianas , Humanos , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/cirurgia , Membrana Epirretiniana/cirurgia , Vitrectomia , Membrana Basal/cirurgia , Membrana Basal/patologia , Tomografia de Coerência Óptica , Retina/patologia , Estudos Retrospectivos
2.
Graefes Arch Clin Exp Ophthalmol ; 255(4): 733-742, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27957600

RESUMO

PURPOSE: Intravitreal anti-vascular endothelial growth factor (VEGF) agents are effective in the treatment of central involving diabetic macular oedema (DMO). Vitreoretinal interface abnormalities (VRIA) are common in patients with DMO, and the effect of these on the response to anti-VEGF treatment is unclear. Furthermore the effect of anti-VEGF agents on the VRIA itself is uncertain. METHOD: Prospective study of consecutive patients treated with ranibizumab (RZB) for DMO as part of routine clinical care in one eye unit over a 1-year period. Visual acuity (Va), central retinal thickness (CRT) and injection frequency data was recorded on an electronic database. Treatment was initiated with four monthly RZB injections and then a monthly PRN regime. All patients underwent high-density spectral-domain optical coherence tomography (SDOCT) at baseline and 12 months. The SDOCTs were graded by two observers masked to the outcome. RESULTS: One hundred and four eyes (77 patients) were included in the analysis. The mean age was 62 years, and 62% were male. The mean presenting vision was 62 letters and CRT 472 µm. Eighty eyes retained stable Va, and 17 had an improvement in Va. At baseline, 39 eyes had associated focal vitreomacular adhesion (VMA) and by 12 months this reduced to 30 (p = 0.04), with 12 releasing VMA and three developing it. Patients with VMA had significantly better final Va than those without VMA. Improvement in CRT was greatest in those where VMA released during the study. Forty-five eyes had some degree of foveal involving epiretinal membrane (ERM) at baseline, and 28 were considered to have clinically significant ERM. There was no clinically relevant change in ERM during the study. Patients with significant ERM at baseline had a lower final vision. Multivariate analysis showed that ERM and more severe retinopathy at baseline were predictive of less visual improvement (p < 0.01). Shorter intraretinal cyst length, ERM and the absence of VMA at baseline were predictive of a worsened anatomical response (p < 0.001). CONCLUSION: VRIA are related to outcome in patients treated with RZB. ERM was associated with a worsened visual and anatomic response, and VMA with an improved anatomical response particularly when spontaneous VMA release occurred during treatment. The presence and severity of ERM was not affected by RZB treatment.


Assuntos
Retinopatia Diabética/complicações , Edema Macular/tratamento farmacológico , Ranibizumab/administração & dosagem , Retina/patologia , Aderências Teciduais/diagnóstico , Corpo Vítreo/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/administração & dosagem , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/tratamento farmacológico , Feminino , Seguimentos , Humanos , Injeções Intravítreas , Edema Macular/complicações , Edema Macular/diagnóstico , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Retina/efeitos dos fármacos , Fatores de Tempo , Aderências Teciduais/etiologia , Tomografia de Coerência Óptica , Fator A de Crescimento do Endotélio Vascular , Acuidade Visual , Corpo Vítreo/efeitos dos fármacos
3.
Graefes Arch Clin Exp Ophthalmol ; 253(5): 691-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25028313

RESUMO

PURPOSE: We sought to assess the effect of two different internal limiting membrane [ILM] peeling techniques carried out during surgery for idiopathic macular holes on the postoperative extent of a dissociated optic nerve fibre layer appearance [DONFL]. METHODS: We collected prospective data of surgical records, videos, and pre- and postoperative imaging of a consecutive series of patients undergoing surgery for idiopathic macular hole with one of two surgeons. One surgeon used a forceps pinch-peel technique to peel the ILM, whereas the other surgeon used a diamond dusted membrane scraper. The extent of any DONFL was measured using spectral domain optical coherence tomography and blue reflectance imaging at three months postoperatively. A proportion of the ILMs removed were examined with transmission electron microscopy. RESULTS: Fifty-seven patients were studied, with 41 in the forceps group and 16 in the scraper group. The groups were well matched, with no significant difference in any preoperative parameters. Some degree of DONFL was observed on the 3-month blue reflectance images in 88 % of the forceps group and 100 % of the scraper group [p = 0.14]. There was a significant difference in the total number of depressions in the nerve fibre layer typical of DONFL on OCT between the two groups [p = 0.001], and general regression analysis showed that the peeling technique used had the only significant association with the degree of DONFL observed. Electron microscopy showed large patches of cellular debris on the retinal side of the peeled ILM in 3 out of 4 cases in the scraper group and 1 out of 12 cases in the forceps group. CONCLUSION: ILM peeling technique and possibly other surgeon-specific factors appear to influence the extent of DONFL observed after ILM peeling macular hole surgery.


Assuntos
Membrana Basal/cirurgia , Fibras Nervosas/ultraestrutura , Procedimentos Cirúrgicos Oftalmológicos , Nervo Óptico/ultraestrutura , Perfurações Retinianas/cirurgia , Idoso , Idoso de 80 Anos ou mais , Membrana Basal/ultraestrutura , Tamponamento Interno , Feminino , Fluorocarbonos/administração & dosagem , Humanos , Masculino , Microscopia Eletrônica de Transmissão , Pessoa de Meia-Idade , Estudos Prospectivos , Perfurações Retinianas/patologia , Hexafluoreto de Enxofre/administração & dosagem , Tomografia de Coerência Óptica , Acuidade Visual/fisiologia , Vitrectomia
4.
BMC Ophthalmol ; 14: 89, 2014 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-25001248

RESUMO

BACKGROUND: The study describes the relationship of retinal vascular geometry (RVG) to severity of diabetic retinopathy (DR), and its predictive role for subsequent development of proliferative diabetic retinopathy (PDR). METHODS: The research project comprises of two stages. Firstly, a comparative study of diabetic patients with different grades of DR. (No DR: Minimal non-proliferative DR: Severe non-proliferative DR: PDR) (10:10: 12: 19). Analysed RVG features including vascular widths and branching angles were compared between patient cohorts. A preliminary statistical model for determination of the retinopathy grade of patients, using these features, is presented. Secondly, in a longitudinal predictive study, RVG features were analysed for diabetic patients with progressive DR over 7 years. RVG at baseline was examined to determine risk for subsequent PDR development. RESULTS: In the comparative study, increased DR severity was associated with gradual vascular dilatation (p = 0.000), and widening of the bifurcating angle (p = 0.000) with increase in smaller-child-vessel branching angle (p = 0.027). Type 2 diabetes and increased diabetes duration were associated with increased vascular width (p = <0.05 In the predictive study, at baseline, reduced small-child vascular width (OR = 0.73 (95% CI 0.58-0.92)), was predictive of future progression to PDR. CONCLUSIONS: The study findings suggest that RVG alterations can act as novel markers indicative of progression of DR severity and establishment of PDR. RVG may also have a potential predictive role in determining the risk of future retinopathy progression.


Assuntos
Retinopatia Diabética/diagnóstico , Vasos Retinianos/patologia , Adulto , Idoso , Estudos Transversais , Técnicas de Diagnóstico Oftalmológico , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Curva ROC , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
5.
Eye (Lond) ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38653749

RESUMO

BACKGROUND/OBJECTIVES: To determine long-term outcomes of patients referred with proliferative diabetic retinopathy (PDR) from diabetic eye screening programmes (DESP) to tertiary care centres in the United Kingdom (UK). METHODS: Retrospective multicentre study of patients referred from two DESPs in the UK over a 36-month period (2007-9) and followed-up for 10 years. Critical outcomes included severe vision loss (SVL) and the need for vitrectomy. Other outcomes assessed included moderate vision loss (MVL), and patient survival time. Univariate and multiple variable Cox proportional hazards regressions were used to analyse survival outcomes. RESULTS: 212 eyes of 150 patients were referred with a diagnosis of PDR. 109 eyes of 72 patients were confirmed to have active PDR and included in the study. 61% of patients had low-risk PDR, while 39% exhibited high-risk features in at least one eye. Eight (7.3%) eyes developed SVL and 16 (14.7%) MVL during follow up. Vitrectomy was required in 24% (95% CI: 15 to 31%) of all PDR eyes and was most commonly performed for vitreous haemorrhage (65%). The 10-year survival in all PDR patients was 76% (95% CI: 63 to 85%) with the mean time to death for all deceased patients being 5.4 ± 3.6 years. On multivariable analysis, only age was found to have a significant association with the survival of patients with PDR. CONCLUSIONS: During the 10 year follow up SVL was uncommon, but MVL occurred in almost one-fifth of the eyes. Approximately 1 in 4 eyes required vitrectomy, highlighting its significance in patient management.

6.
J Ophthalmol ; 2023: 5747010, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37650051

RESUMO

In ophthalmology, optical coherence tomography (OCT) is a widely used imaging modality, allowing visualisation of the structures of the eye with objective and quantitative cross-sectional three-dimensional (3D) volumetric scans. Due to the quantity of data generated from OCT scans and the time taken for an ophthalmologist to inspect for various disease pathology features, automated image analysis in the form of deep neural networks has seen success for the classification and segmentation of OCT layers and quantification of features. However, existing high-performance deep learning approaches rely on huge training datasets with high-quality annotations, which are challenging to obtain in many clinical applications. The collection of annotations from less experienced clinicians has the potential to alleviate time constraints from more senior clinicians, allowing faster data collection of medical image annotations; however, with less experience, there is the possibility of reduced annotation quality. In this study, we evaluate the quality of diabetic macular edema (DME) intraretinal fluid (IRF) biomarker image annotations on OCT B-scans from five clinicians with a range of experience. We also assess the effectiveness of annotating across multiple sessions following a training session led by an expert clinician. Our investigation shows a notable variance in annotation performance, with a correlation that depends on the clinician's experience with OCT image interpretation of DME, and that having multiple annotation sessions has a limited effect on the annotation quality.

7.
Ophthalmol Retina ; 2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38040055

RESUMO

PURPOSE: Although previous studies have demonstrated the efficacy of faricimab in treatment-naive patients with neovascular age-related macular degeneration (nAMD), its outcomes in patients switched from aflibercept are less understood. This study aimed to assess clinical anatomical and functional outcomes of switching to faricimab in patients undergoing aflibercept intravitreal injections (IVIs) for nAMD with suboptimal response. DESIGN: Retrospective case series. SUBJECTS: Patients with nAMD at a single tertiary care center who were switched from aflibercept to faricimab due to persistent suboptimal response. METHODS: Patients had received a minimum of 6 consecutive IVIs of aflibercept and showed persistent presence of intraretinal (IRF) or subretinal fluid (SRF) on OCT despite receiving aflibercept at 4 or 6-weekly intervals at the time of the switch. Patients receiving 4-weekly aflibercept were switched with either 2 or 3 loading doses of 4-weekly faricimab injections. Regression models were used to identify predictors of clinical outcomes. MAIN OUTCOME MEASURES: Visual acuity, central macular thickness (CMT), and OCT parameters were assessed preswitch and postswitch. RESULTS: Eighty-one eyes of 68 patients were included. The mean age was 79.1 years (standard deviation: 8.9), and females constituted 53% of cases. A statistically significant reduction in CMT was observed postswitch (P < 0.0001). The proportion of cases with IRF (P = 0.0219) and SRF (P < 0.000) decreased significantly. Overall clinical improvement on OCT was noted in 80% of patients. No significant improvement in ETDRS vision was observed. There was no evidence that switching regimen (2 vs. 3 loading doses) had an independent effect on clinical outcomes. CONCLUSION: Among patients with treatment-resistant nAMD, switching from aflibercept to faricimab may serve as a safe and effective option. Significant anatomical improvements were observed, with a trend toward visual stability. The loading regimen with 2 faricimab injections appeared to be sufficient for nonnaive patients. However, a longer follow-up and larger studies are warranted to confirm these findings. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

8.
BMJ Open Ophthalmol ; 6(1): e000696, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34192155

RESUMO

First-line treatment of centrally involved diabetic macular oedema (CI-DMO) is often with an anti-vascular endothelial growth factor (anti-VEGF) agent. Although this can provide efficacy in the majority of eyes, a sizeable proportion do not respond sufficiently and many continue to receive anti-VEGF therapy after it may be optimal. This imposes a treatment burden on both patients and clinicians and, most importantly of all, can be sight threatening. Changing treatment to an intravitreal corticosteroid implant at the appropriate time may help optimise patient outcomes and reduce injection frequency, thereby reducing treatment burden. Eight retina specialists convened to discuss how to ensure eyes with CI-DMO receiving intravitreal anti-VEGF therapy are evaluated for a potential change to intravitreal corticosteroid therapy at the most effective time in their treatment journey. They concluded that clear criteria on when to consider changing treatment would be helpful and so developed a consensus guideline covering key decision points such as when and how to assess response to anti-VEGF therapy, when to consider a change to corticosteroid therapy and when and how to assess the response to corticosteroid therapy. The guideline was developed before the COVID-19 pandemic but, with the additional challenges arising from this including even greater pressure on clinic capacity, it is more important than ever to reconsider current working practices and adopt changes to improve patient care while also easing pressure on clinic capacity, reducing hospital visits and maintaining patient safety. This publication therefore also includes suggestions for adapting the guidelines in the COVID-19 era.

9.
Curr Med Res Opin ; 36(6): 959-965, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32267790

RESUMO

Objectives: To evaluate central foveal thickness (CFT) variability and accompanying changes in visual acuity (VA) 12 months before and after treatment with the 190 mcg fluocinolone acetonide (FAc) intravitreal implant for diabetic macular edema (DME).Methods: The Iluvien Clinical Evidence cohort study in the United Kingdom (ICE-UK) investigated the effectiveness of the FAc implant in people treated at 13 hospitals from April 2013 to April 2015. The following parameters were calculated for CFT for each patient: mean, standard deviation (SD), retinal thickness amplitude (RTA, the difference between maximum and minimum values), and coefficient of variation (CV).Results: In 149 eyes with ≥2 CFT observations both before and after FAc implantation, the median VA was 50 ETDRS letters at implantation. Mean CFT was 487 µm at implantation and 135 µm at 12 months post-implant. Before implantation, the mean CV and mean SD for CFT were 24.6% and 112 µm, respectively; the mean RTA was 254 µm. A statistically significant (p < .001) decrease in all three parameters was observed after implantation (18.3%, 68.2 µm and 146 µm, respectively). There was an association between CFT change between extremes and the corresponding change in VA (Pearson's correlation coefficient, r = -0.292, p < .001, prior to the implant; r = -0.379, p < .001, post-implant).Conclusions: After accounting for the reduction in CFT, retinal thickness stabilized following FAc implantation. There might be VA benefits in reducing variability in CFT over time. This merits further exploration but would require more frequent CFT observations in order to properly determine patterns of retinal thickness variability.


Assuntos
Retinopatia Diabética/tratamento farmacológico , Fluocinolona Acetonida/administração & dosagem , Edema Macular/tratamento farmacológico , Retina/patologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Retinopatia Diabética/patologia , Implantes de Medicamento/uso terapêutico , Feminino , Humanos , Injeções Intravítreas , Edema Macular/patologia , Masculino , Pessoa de Meia-Idade , Acuidade Visual
10.
BMJ Open Ophthalmol ; 5(1): e000404, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32844119

RESUMO

OBJECTIVE: Full-thickness macular holes (MH) are classified principally by size, which is one of the strongest predictors of anatomical and visual success. Using a three-dimensional (3D) automated image processing algorithm, we analysed optical coherence tomography (OCT) images of 104 MH of patients, comparing MH dimensions and morphology with clinician-acquired two-dimensional measurements. METHODS AND ANALYSIS: All patients underwent a high-density central horizontal scanning OCT protocol. Two independent clinicians measured the minimum linear diameter (MLD) and maximum base diameter. OCT images were also analysed using an automated 3D segmentation algorithm which produced key parameters including the respective maximum and minimum diameter of the minimum area (MA) of the MH, as well as volume and surface area. RESULTS: Using the algorithm-derived values, MH were found to have significant asymmetry in all dimensions. The minima of the MA were typically approximately 90° to the horizontal, and differed from their maxima by 55 µm. The minima of the MA differed from the human-measured MLD by a mean of nearly 50 µm, with significant interobserver variability. The resultant differences led to reclassification using the International Vitreomacular Traction Study Group classification in a quarter of the patients (p=0.07). CONCLUSION: MH are complex shapes with significant asymmetry in all dimensions. We have shown how 3D automated analysis of MH describes their dimensions more accurately and repeatably than human assessment. This could be used in future studies investigating hole progression and outcome to help guide optimum treatments.

11.
J Cataract Refract Surg ; 34(10): 1640-3, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18812112

RESUMO

We describe a technique for heavy silicone oil removal combined with phacoemulsification and intraocular lens insertion without scleral incisions or sutures using a modified 16-gauge cannula. The technique is less invasive than other techniques for removing silicone oil and does not interfere with the uveal tract or the peripheral retina.


Assuntos
Drenagem/métodos , Facoemulsificação/métodos , Óleos de Silicone , Cateterismo/instrumentação , Humanos , Implante de Lente Intraocular , Pupila , Perfurações Retinianas/cirurgia , Acuidade Visual
12.
BMC Ophthalmol ; 8: 13, 2008 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-18651983

RESUMO

BACKGROUND: Stereoscopic assessment of the optic disc morphology is an important part of the care of patients with glaucoma. The aim of this study was to assess stereoviewing of stereoscopic optic disc images using an example of the new technology of autostereoscopic screens compared to the liquid shutter goggles. METHODS: Independent assessment of glaucomatous disc characteristics and measurement of optic disc and cup parameters whilst using either an autostereoscopic screen or liquid crystal shutter goggles synchronized with a view switching display. The main outcome measures were inter-modality agreements between the two used modalities as evaluated by the weighted kappa test and Bland Altman plots. RESULTS: Inter-modality agreement for measuring optic disc parameters was good [Average kappa coefficient for vertical Cup/Disc ratio was 0.78 (95% CI 0.62-0.91) and 0.81 (95% CI 0.6-0.92) for observer 1 and 2 respectively]. Agreement between modalities for assessing optic disc characteristics for glaucoma on a five-point scale was very good with a kappa value of 0.97. CONCLUSION: This study compared two different methods of stereo viewing. The results of assessment of the different optic disc and cup parameters were comparable using an example of the newly developing autostereoscopic display technologies as compared to the shutter goggles system used. The Inter-modality agreement was high. This new technology carries potential clinical usability benefits in different areas of ophthalmic practice.


Assuntos
Técnicas de Diagnóstico Oftalmológico , Glaucoma de Ângulo Aberto/diagnóstico , Processamento de Imagem Assistida por Computador/métodos , Hipertensão Ocular/diagnóstico , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Idoso , Diagnóstico Diferencial , Progressão da Doença , Feminino , Glaucoma de Ângulo Aberto/complicações , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/complicações , Doenças do Nervo Óptico/etiologia , Reprodutibilidade dos Testes
13.
Ther Deliv ; 9(8): 547-556, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29943691

RESUMO

Diabetic macular edema (DME) is one of the major causes of blindness, caused primarily by hyperglycemia and results from multiple pathological processes mostly secondary to increased levels of VEGF and other inflammatory cytokines. DME management includes control of systemic risk factors together with laser photocoagulation, frequent intraocular injections of anti-VEGF agents and steroids implants. Recent adoption of novel alternative drug delivery options has led to the development of sustained release ocular implants with longer duration of action with less injection frequency. This article will review the pharmacology and clinical data in terms of efficacy, safety and benefits of the sustained release steroid implants in treatment of DME with special emphasis on the fluocinolone acetonide ILUVIEN® implant.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Retinopatia Diabética/tratamento farmacológico , Fluocinolona Acetonida/administração & dosagem , Edema Macular/tratamento farmacológico , Inibidores da Angiogênese/economia , Catarata/induzido quimicamente , Catarata/epidemiologia , Ensaios Clínicos Fase II como Assunto , Análise Custo-Benefício , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/efeitos adversos , Preparações de Ação Retardada/economia , Preparações de Ação Retardada/farmacocinética , Retinopatia Diabética/economia , Implantes de Medicamento , Fluocinolona Acetonida/efeitos adversos , Fluocinolona Acetonida/economia , Fluocinolona Acetonida/farmacocinética , Humanos , Pressão Intraocular/efeitos dos fármacos , Injeções Intravítreas/efeitos adversos , Injeções Intravítreas/economia , Edema Macular/economia , Modelos Econômicos , Qualidade de Vida , Resultado do Tratamento , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores , Acuidade Visual/efeitos dos fármacos
14.
IEEE Trans Med Imaging ; 37(2): 580-589, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29408786

RESUMO

Macular holes are blinding conditions, where a hole develops in the central part of retina, resulting in reduced central vision. The prognosis and treatment options are related to a number of variables, including the macular hole size and shape. High-resolution spectral domain optical coherence tomography allows precise imaging of the macular hole geometry in three dimensions, but the measurement of these by human observers is time-consuming and prone to high inter- and intra-observer variability, being characteristically measured in 2-D rather than 3-D. We introduce several novel techniques to automatically retrieve accurate 3-D measurements of the macular hole, including: surface area, base area, base diameter, top area, top diameter, height, and minimum diameter. Specifically, we introduce a multi-scale 3-D level set segmentation approach based on a state-of-the-art level set method, and we introduce novel curvature-based cutting and 3-D measurement procedures. The algorithm is fully automatic, and we validate our extracted measurements both qualitatively and quantitatively, where our results show the method to be robust across a variety of scenarios. Our automated processes are considered a significant contribution for clinical applications.


Assuntos
Imageamento Tridimensional/métodos , Retina/diagnóstico por imagem , Perfurações Retinianas/diagnóstico por imagem , Tomografia de Coerência Óptica/métodos , Algoritmos , Humanos
15.
Eur J Ophthalmol ; 27(3): 357-362, 2017 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-28165610

RESUMO

PURPOSE: To conduct an observational, multicenter study to evaluate real-world clinical efficacy and safety of the 0.2 µg/day fluocinolone acetonide (FAc) implant in the treatment of patients with chronic diabetic macular edema (DME) in 3 large hospital ophthalmology departments in the United Kingdom. METHODS: Fluocinolone acetonide implants were inserted into the study eyes following a suitable washout period; phakic eyes received FAc implant following cataract surgery. Follow-up visits took place 2-4 weeks postinjection and then at 3, 6, and 12 months; change in central macular thickness (CMT) from baseline was measured by optical coherence tomography and best-corrected visual acuity (BCVA) was also assessed. Adverse events and changes in intraocular pressure (IOP) were recorded in order to evaluate the safety profile for the FAc implant. RESULTS: Improvements in BCVA and CMT were observed from 3 months and sustained for the duration of observation. At 12 months, the overall mean change from baseline CMT was -126 µm and mean increase in BCVA from baseline was 5.1 letters. Increases in IOP following FAc implant were easily managed with IOP-lowering medication. Implant migration into the anterior chamber occurred in 2 eyes where prior vitrectomy had resulted in a posterior capsule defect; this was rectified and resolved. CONCLUSIONS: The results of this study provide further efficacy and safety profile data for FAc implant treatment of chronic DME in a real-world clinical setting; the FAc implant appears to be a valuable therapeutic approach for patients with chronic DME who have suboptimal response to other treatment options.


Assuntos
Retinopatia Diabética/tratamento farmacológico , Fluocinolona Acetonida/administração & dosagem , Edema Macular/tratamento farmacológico , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Retinopatia Diabética/complicações , Retinopatia Diabética/diagnóstico , Relação Dose-Resposta a Droga , Implantes de Medicamento , Feminino , Glucocorticoides/administração & dosagem , Humanos , Injeções Intravítreas , Edema Macular/diagnóstico , Edema Macular/etiologia , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Reino Unido
16.
J Cataract Refract Surg ; 32(7): 1238-40, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16857516

RESUMO

We present a case in which a new organism, Sphingomonas paucimobilis, caused endophthalmitis after phacoemulsification in a 73-year-old woman. The case shows a recurrent acute endophthalmitis with complete resolution only after vitrectomy. This organism has not been described as a cause of endophthalmitis and was resistant to initial medical management. We also describe an interaction between this organism and a co-infective organism that may account for the unusual clinical course.


Assuntos
Endoftalmite/microbiologia , Infecções Oculares Bacterianas/etiologia , Infecções por Bactérias Gram-Negativas/etiologia , Facoemulsificação/efeitos adversos , Complicações Pós-Operatórias , Sphingomonas/isolamento & purificação , Idoso , Antibacterianos/uso terapêutico , Terapia Combinada , Quimioterapia Combinada , Endoftalmite/diagnóstico , Endoftalmite/terapia , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/terapia , Feminino , Infecções por Bactérias Gram-Negativas/diagnóstico , Infecções por Bactérias Gram-Negativas/terapia , Humanos , Recidiva , Vitrectomia , Corpo Vítreo/microbiologia
17.
BMC Ophthalmol ; 6: 3, 2006 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-16409642

RESUMO

BACKGROUND: Few previous reports have described the presence of retinal refractile opacities at the macular area in patients presenting with longstanding peripheral retinal detachment. The exact nature of these opacities is unknown. CASE PRESENTATION: Two patients were referred with an abnormal appearance of refractile opacities in the macular area noted during routine examination. Both were found to have longstanding peripheral retinal detachments. Subretinal fluid analysis of one patient revealed the presence of multiple birefringent crystals. We hypothesise that these crystals are the origin of the refractile macular opacities noted. CONCLUSION: This report describes the rare presentation of asymptomatic peripheral retinal detachment by the detection of refractile macular opacities on routine examination. It highlights the importance of meticulous peripheral retinal examination in these cases. The article also describes the findings of the subretinal fluid analysis and discusses the possible hypothesis behind their appearance.


Assuntos
Macula Lutea/metabolismo , Descolamento Retiniano/complicações , Descolamento Retiniano/metabolismo , Doenças Retinianas/complicações , Doenças Retinianas/metabolismo , Adulto , Doença Crônica , Cristalização , Fundo de Olho , Humanos , Masculino , Pessoa de Meia-Idade , Descolamento Retiniano/diagnóstico , Doenças Retinianas/diagnóstico , Espalhamento de Radiação , Tomografia de Coerência Óptica
18.
BMC Ophthalmol ; 5: 15, 2005 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-15972106

RESUMO

BACKGROUND: The management of diabetic patients with refractory macular oedema or patients with no adequate pre-operative view to administer laser treatment provide a challenge to the ophthalmologist. We wished to assess the use, safety and effect of intravitreal triamcinolone injection at the time of cataract surgery in patients with diabetic foveal oedema and sight limiting lens opacities. METHOD: This was a longitudinal non-randomised prospective pilot study in 18 eyes (12 patients). All patients had visually significant lens opacities and either persistent diabetic foveal oedema unresponsive to laser treatment-group A, or foveal oedema with no adequate pre-operative view for laser treatment- group B. The cataract surgery was carried out under full aseptic technique using a self-sealing temporal incision and a foldable acrylic lens. Intravitreal triamcinolone was given infratemporally pars plana at the completion of the cataract surgery. The patients were reviewed at day 5, 2 weeks, 2 months and then every 3 months as required. The Wilcoxin matched-pairs test was used to assess the significance of the improvement in visual acuity at 2 months. RESULTS: Twelve patients with a total of 18 eyes were included in the study. There were 10 patients (15 eyes) in group A and 3 patients (3 eyes) in group B. Preoperatively 16 of the 18 eyes had a visual acuity of 6/24 or worse. Postoperatively 83% of patients had completely dry foveae at 2 weeks. Best-corrected visual acuities at two months review ranged from 6/6 to CF with 9 eyes (50%) achieving 6/12 or better (7 eyes (47%) in group A and 2 eyes (67%) in group B). Three eyes had no recorded improvement in visual acuity, but no eyes had deterioration in acuity. The improvement in visual acuity was significant at p = 0.001. There were no significant sight threatening complications. CONCLUSION: Intravitreal triamcinolone has been shown to lead to an improvement in macular oedema and visual improvement in diabetic patients not undergoing cataract surgery but has not, to our knowledge, been previously used in a study like this one.We suggest that intravitreal injection at the time of cataract surgery could be carried out safely with encouraging visual outcomes in patients with diabetic foveal oedema and cataract.


Assuntos
Catarata/terapia , Retinopatia Diabética/tratamento farmacológico , Glucocorticoides/administração & dosagem , Edema Macular/tratamento farmacológico , Facoemulsificação/métodos , Triancinolona Acetonida/administração & dosagem , Idoso , Catarata/complicações , Terapia Combinada , Retinopatia Diabética/complicações , Feminino , Seguimentos , Fóvea Central , Humanos , Injeções , Implante de Lente Intraocular , Edema Macular/complicações , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual
19.
J Cataract Refract Surg ; 30(2): 414-7, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15030833

RESUMO

PURPOSE: To evaluate the effect of on-axis opposite clear corneal incisions (OCCIs) in phacoemulsification on reducing preoperative corneal astigmatism and to predict the astigmatic outcome of the incisions. SETTING: Royal Eye Infirmary, Dorset County Hospital, and Winterbourne Hospital, Dorchester, Dorset, and the Department of Ophthalmology, East Somerset Hospital, Yeovil, Somerset, United Kingdom. METHODS: This prospective study included all patients (n = 103) who had on-axis OCCIs as a part of routine phacoemulsification with foldable intraocular lens (IOL) implantation performed by 1 surgeon during 2000. Keratometry was done 6 to 8 weeks postoperatively. The differences in the preoperative and postoperative corneal astigmatism and corneal spherical equivalent (SE) were recorded. Surgically induced astigmatism (SIA) was calculated using vector analysis. RESULTS: The mean reduction in corneal astigmatism was 0.50 diopter (D) (P<.001). The mean SIA was 1.57 D (95% confidence interval [CI], 1.42 to 1.71). There was a weak association between the SIA and the patient's age and axis of preoperative astigmatism. The mean change in SE was +0.02 D (95% CI, -0.08 to +0.12). CONCLUSIONS: Results indicate that on-axis OCCIs are a reliable and practical way of reducing preexisting corneal astigmatism. The change in SE was negligible and thus can be ignored during biometry.


Assuntos
Astigmatismo/prevenção & controle , Córnea/cirurgia , Implante de Lente Intraocular/métodos , Facoemulsificação/métodos , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/fisiopatologia , Córnea/fisiopatologia , Topografia da Córnea , Humanos , Complicações Intraoperatórias/prevenção & controle , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Estudos Prospectivos
20.
J Cataract Refract Surg ; 38(2): 249-55, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22154012

RESUMO

PURPOSE: To assess the impact on incision size of IOL implantation using a new motorized intraocular lens (IOL) injector versus a standard manual injector. SETTING: Cataract Treatment Centre, Sunderland Eye Infirmary, Sunderland, United Kingdom. DESIGN: Comparative case series. METHODS: All patients received an Acrysof SN60WF IOL implanted using a D cartridge and an Autosert motorized injector at fast speed, an Autosert motorized injector at slow speed, or a manual Monarch injector. Each group had a range of preimplantation incision sizes (1.9 mm, 2.0 mm, 2.1 mm, 2.2 mm, 2.3 mm). Incision gauges were used to measure the incision width before and immediately after IOL implantation. RESULTS: The study recruited 256 patients. All incisions that were 1.8 mm at the commencement of surgery increased in size by the end of irrigation/aspiration. The motorized injector used with a fast speed (4.4 mm/sec) caused significantly less incision enlargement than the manual injector for all preimplantation incision sizes tested (P<.02). For 4 of the 5 preimplantation incision size subgroups, the motorized injector used at slow speed (1.5 mm/sec) produced less incision stretch than the manual injector, although the difference did not reach statistical significance. CONCLUSION: The motorized injector was easy to use, and its use with an injection speed of 4.4 mm/sec caused significantly less incision enlargement than the manual injector during IOL implantation.


Assuntos
Córnea/cirurgia , Implante de Lente Intraocular/instrumentação , Lentes Intraoculares , Estruturas Criadas Cirurgicamente/patologia , Resinas Acrílicas , Drenagem , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular/métodos , Microcirurgia , Facoemulsificação , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA