Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Nucl Cardiol ; 30(5): 1879-1885, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36918460

RESUMO

BACKGROUND: The aim of this study was to estimate the impact of respiratory and electrocardiogram (ECG)-gated FDG positron emission tomography (PET)/computed tomography (CT) on the diagnosis of cardiac sarcoidosis (CS). METHODS AND RESULTS: Imaging from thirty-one patients was acquired on a PET/CT scanner equipped with a respiratory- and ECG-gating system. Non-gated PET images and three kinds of gated PET/CT images were created from identical list-mode clinical PET data: respiratory-gated PET during expiration (EX), ECG-gated PET at end diastole (ED), and ECG-gated PET at end systole (ES). The maximum standardized uptake value (SUVmax) and cardiac metabolic volume (CMV) were measured, and the locations of FDG accumulation were analyzed using a polar map. The mean SUVmax of the subjects was significantly higher after application of either respiratory-gated or ECG-gated reconstruction. Conversely, the mean CMV was significantly lower following the application of respiratory-gated or ECG-gated reconstruction. The segment showing maximum accumulation was shifted to the adjacent segment in 25.8%, 38.7%, and 41.9% of cases in EX, ED, and ES images, respectively. CONCLUSION: In FDG PET/CT scanning for the diagnosis of CS, gated scanning is likely to increase quantitative accuracy, but the effect depends on the location and synchronization method.


Assuntos
Infecções por Citomegalovirus , Sarcoidose , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons/métodos , Eletrocardiografia , Sarcoidose/diagnóstico por imagem
2.
BMC Cancer ; 22(1): 1176, 2022 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-36376801

RESUMO

BACKGROUND: Induction or adjuvant therapies are not always beneficial for thoracic esophageal squamous cell carcinoma (ESCC) patients, and it is thus important to identify patients at high risk for postoperative ESCC recurrence. We investigated the usefulness of the total metabolic tumor volume (TMTV) for predicting the postoperative recurrence of thoracic ESCC. METHODS: We retrospectively analyzed the cases of 163 thoracic ESCC patients (135 men, 28 women; median age of 66 [range 34-82] years) treated at our hospital in 2007-2012. The TMTV was calculated from the fluorine-18 fluorodeoxyglucose (18F-FDG) uptake in the primary lesion and lymph node metastases. The optimal cut-off values for relapse and non-relapse were obtained by the time-dependent receiver operating curve analyses. Relapse-free survival (RFS) was evaluated by the Kaplan-Meier method, and between-subgroup differences in survival were analyzed by log-rank test. The prognostic significance of metabolic parameters and clinicopathological variables was assessed by a Cox proportional hazard regression analysis. The difference in the failure patterns after surgical resection was evaluated using the χ2-test. RESULTS: The optimal cut-off value of TMTV for discriminating relapse from non-relapse was 3.82. The patients with a TMTV ≥3.82 showed significantly worse prognoses than those with low values (p < 0.001). The TMTV was significantly related to RFS (model 1 for preoperative risk factors: TMTV: hazard ratio [HR] =2.574, p = 0.004; model 2 for preoperative and postoperative risk factors: HR = 1.989, p = 0.044). The combination of the TMTV and cN0-1 or pN0-1 stage significantly stratified the patients into low-and high-risk recurrence groups (TMTV cN0-1, p < 0.001; TMTV pN0-1, p = 0.004). The rates of hematogenous and regional lymph node metastasis were significantly higher in the patients with TMTV ≥3.82 than those with low values (hematogenous metastasis, p < 0.001, regional lymph node metastasis, p = 0.011). CONCLUSIONS: The TMTV was a more significantly independent prognostic factor for RFS than any other PET parameter in patients with resectable thoracic ESCC. The TMTV may be useful for the identifying thoracic ESCC patients at high risk for postoperative recurrence and for deciding the patient management.


Assuntos
Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Escamosas do Esôfago/diagnóstico por imagem , Carcinoma de Células Escamosas do Esôfago/cirurgia , Carcinoma de Células Escamosas do Esôfago/patologia , Carga Tumoral , Neoplasias Esofágicas/diagnóstico por imagem , Neoplasias Esofágicas/cirurgia , Metástase Linfática , Estudos Retrospectivos , Estadiamento de Neoplasias , Recidiva Local de Neoplasia/patologia , Fluordesoxiglucose F18 , Prognóstico
3.
J Nucl Cardiol ; 29(2): 753-764, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33000410

RESUMO

BACKGROUND: Although each 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and cardiac magnetic resonance (CMR) imaging with late gadolinium enhancement (LGE) has been used to diagnose cardiac sarcoidosis (CS), active CS is still misdiagnosed. METHODS: Active CS, diagnosed by PET alone, was defined as focal or focal on diffuse FDG uptake pattern. In fusion PET/CMR imaging, using a regional analysis with AHA 17-segment model, the patients were categorized into four groups: (1) PET-/LGE-, (2) PET+/LGE-, (3) PET+/LGE+, and (4) PET-/LGE+. PET+/LGE+ was defined as active CS. RESULTS: 74 Patients with suspected CS were enrolled. Between PET alone and fusion PET/CMR imaging, 20 cases had mismatch evaluations of active CS, and most had diffuse or focal on diffuse FDG uptake pattern on PET alone imaging. 40 Patients fulfilled the 2016 the Japanese Circulation Society diagnostic criteria for CS. The interobserver diagnostic agreement was excellent (κ statistics 0.89) and the overall accuracy for diagnosing CS was 87.8% in fusion PET/CMR imaging, which were superior to those in PET alone imaging (0.57 and 82.4%, respectively). In a sub-analysis of diffuse and focal on diffuse patterns, the agreement (κ statistics 0.86) and overall accuracy (81.8%) in fusion PET/CMR imaging were still better. CONCLUSIONS: Fusion PET/CMR imaging with regional analysis offered reliable and accurate diagnosis of CS, covering low diagnostic area by FDG-PET alone.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/patologia , Meios de Contraste , Fluordesoxiglucose F18 , Gadolínio , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Sarcoidose/diagnóstico por imagem , Sarcoidose/patologia
4.
Dement Geriatr Cogn Disord ; 49(3): 255-263, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32814322

RESUMO

OBJECTIVE: The aim was to examine the association between connectivity changes in the default mode network (DMN) and the progression of idiopathic normal pressure hydrocephalus (iNPH). METHODS: We retrospectively recruited cases of preclinical and clinical iNPH from 2,196 patients who had received whole-body 18F-fluorodeoxyglucose-positron emission tomography/computed tomography (FDG-PET/CT) scanning. We included 31 cases with asymptomatic ventriculomegaly with features of iNPH on MRI (AVIM; reported as preclinical iNPH) and 12 with iNPH. We performed a voxel-based analysis of the brain FDG-PET images of the AVIM and iNPH groups as well as for each background-matched normal control (NC) group, using Statistical Parametric Mapping 12. Volume of interest (VOI)-based analysis was also performed. We set the VOI as the region from the precuneus to the posterior cingulate cortices (PCC), and compared the mean regional standardized uptake value ratio (SUVR) between the AVIM and iNPH group FDG-PET/CT images and each corresponding NC group. RESULTS: The voxel-based analysis showed a greater decreased FDG uptake in the PCC in the iNPH group than in the AVIM group. The VOI-based analysis revealed no significant difference in the mean SUVR of the AVIM group and the corresponding NC group, but that of the iNPH group was significantly lower than that of its corresponding NC group. CONCLUSIONS: DMN connectivity was reduced in the clinical iNPH group but not in the preclinical group. These data suggest that alterations in the functional connectivity of the DMN are related to the onset of iNPH symptoms.


Assuntos
Rede de Modo Padrão/fisiopatologia , Hidrocefalia de Pressão Normal , Idoso , Conectoma/métodos , Correlação de Dados , Progressão da Doença , Feminino , Humanos , Hidrocefalia de Pressão Normal/diagnóstico , Hidrocefalia de Pressão Normal/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Masculino , Gravidade do Paciente , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Estudos Retrospectivos
5.
BMC Med Imaging ; 20(1): 15, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-32041550

RESUMO

BACKGROUND: The Logan graphical analysis (LGA) algorithm is widely used to quantify receptor density for parametric imaging in positron emission tomography (PET). Estimating receptor density, in terms of the non-displaceable binding potential (BPND), from the LGA using the ordinary least-squares (OLS) method has been found to be negatively biased owing to noise in PET data. This is because OLS does not consider errors in the X-variable (predictor variable). Existing bias reduction methods can either only reduce the bias slightly or reduce the bias accompanied by increased variation in the estimates. In this study, we addressed the bias reduction problem by applying a different regression method. METHODS: We employed least-squares cubic (LSC) linear regression, which accounts for errors in both variables as well as the correlation of these errors. Noise-free PET data were simulated, for 11C-carfentanil kinetics, with known BPND values. Statistical noise was added to these data and the BPNDs were re-estimated from the noisy data by three methods, conventional LGA, multilinear reference tissue model 2 (MRTM2), and LSC-based LGA; the results were compared. The three methods were also compared in terms of beta amyloid (A ß) quantification of 11C-Pittsburgh compound B brain PET data for two patients with Alzheimer's disease and differing A ß depositions. RESULTS: Amongst the three methods, for both synthetic and actual data, LSC was the least biased, followed by MRTM2, and then the conventional LGA, which was the most biased. Variations in the LSC estimates were smaller than those in the MRTM2 estimates. LSC also required a shorter computational time than MRTM2. CONCLUSIONS: The results suggest that LSC provides a better trade-off between the bias and variability than the other two methods. In particular, LSC performed better than MRTM2 in all aspects; bias, variability, and computational time. This makes LSC a promising method for BPND parametric imaging in PET studies.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Peptídeos beta-Amiloides/química , Isótopos de Carbono/farmacocinética , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Algoritmos , Doença de Alzheimer/metabolismo , Peptídeos beta-Amiloides/metabolismo , Viés , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Isótopos de Carbono/química , Fentanila/análogos & derivados , Fentanila/química , Humanos , Análise dos Mínimos Quadrados , Tomografia por Emissão de Pósitrons , Razão Sinal-Ruído
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 76(12): 1237-1247, 2020.
Artigo em Japonês | MEDLINE | ID: mdl-33342942

RESUMO

Targeted radioisotope therapy (TRT) is a radiotherapy using radioisotope or drug incorporating it and has been used as a treatment for selectively irradiating cancer cells. In recent years, interest in TRT has increased due to improvements in radionuclide production technology, development of new drugs and imaging modalities, and improvements in radiation technology. In order to enhance the effect of TRT, measurement of individual radiation doses to tumor tissue and organs at risk is important using highly quantitative nuclear medicine images. In this paper, we present a review of literature on optimization of TRT, which is a new research area from the perspective of radiation technology.


Assuntos
Medicina Nuclear , Tecnologia Radiológica , Radioisótopos , Cintilografia
7.
Artigo em Japonês | MEDLINE | ID: mdl-30787223

RESUMO

PURPOSE: The dosimetric error due to immobilization devices has been highlighted by the AAPM Task Group 176. We developed a novel low-radiation-absorbent immobilization adaptor (HMA), which can be used with a Styrofoam headrest for head and neck region in radiotherapy. The purpose of this study was to investigate the impact of the HMA on the dose distribution and compare with a commercially released plastic adapter. METHODS: Computed tomography (CT) simulation and dose calculation on a treatment planning system (TPS) were performed by the use of HMA and the plastic adapter with a cylindrical phantom. Both the adapters were placed on the phantom upside and the attenuation rate was measured. Gantry angles were changed at every 1°interval from 0°to 50°for measurements. The measured dose was normalized by the value of 90°. The treatment equipment was TrueBeam (Varian medical systems); X-ray energies were set on 4, 6 and 10 MV, respectively. The measured attenuation rates were also compared with calculation results of TPS. RESULTS: The highest differences on attenuation rate of both the adapters were observed at a gantry angle of 32.0°; the differences were 3.0% at 4 MV, 2.7% at 6 MV and 3.0% at 10 MV, respectively, and lower absorption was HMA. TPS calculation results of monitor unit for the HMA were within 1.0% in each energy. CONCLUSION: The HMA was able to provide absorption dose and calculation errors lower than a commercially released adapter. It can also provide more accurate dose delivery for radiotherapy in head and neck because of the low absorption characteristics.


Assuntos
Neoplasias de Cabeça e Pescoço , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Imagens de Fantasmas , Radiometria , Dosagem Radioterapêutica
8.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 74(12): 1443-1448, 2018 12.
Artigo em Japonês | MEDLINE | ID: mdl-30568095

RESUMO

Radionuclide therapy has been used to help manage a range of diseases and has a role of growing importance, with an increasing impact on clinical practice globally. A survey in the field of Radionuclide therapy was conducted by reviewing 4199 science abstracts of main conference (Japanese Society of Radiological Technology, Japanese Society of Nuclear Medicine, Japanese Society of Nuclear Medicine Technology, Society of Nuclear Medicine and Molecular Imaging, European Association of Nuclear Medicine) held in 2016. This survey consisted of research content, modality for evaluation, dosimetry, radionuclide, and researcher's country. There tend to be a lot of studies related to targeted radionuclide therapy more than Japan (4%) in the United States (11%) or Europe (13%). Radiopharmaceuticals still un-approving in Japan were used in some of these studies. And many studies on dosimetry using PET or SPECT imaging were confirmed in the United States (37%) or in Europe (25%) compared with in Japan (14%). This survey has clarified the current status of Japan and global trend in the field of radionuclide therapy.


Assuntos
Medicina Nuclear , Radioisótopos , Europa (Continente) , Japão , Radioisótopos/uso terapêutico , Cintilografia , Inquéritos e Questionários , Estados Unidos
9.
J Appl Clin Med Phys ; 18(3): 215-220, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28422397

RESUMO

Tungsten functional paper (TFP), which contains 80% tungsten by weight, has radiation-shielding properties. We investigated the use of TFP for the protection of operators during interventional or therapeutic angiography. The air kerma rate of scattered radiation from a simulated patient was measured, with and without TFP, using a water-equivalent phantom and fixed C-arm fluoroscopy. Measurements were taken at the level of the operator's eye, chest, waist, and knee, with a variable number of TFP sheets used for shielding. A Monte Carlo simulation was also utilized to analyze the dose rate delivered with and without the TFP shielding. In cine mode, when the number of TFP sheets was varied through 1, 2, 3, 5, and 10, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.9%, 29.9%, 41.6%, 50.4%, and 56.2%; at chest level, 25.3%, 33.1%, 34.9%, 46.1%, and 44.3%; at waist level, 45.1%, 57.0%, 64.4%, 70.7%, and 75.2%; and at knee level, 2.1%, 2.2%, 2.1%, 2.1%, and 2.1%. In fluoroscopy mode, the respective reduction in the air kerma rate relative to no TFP shielding was as follows: at eye level, 24.8%, 30.3%, 34.8%, 51.1%, and 58.5%; at chest level, 25.8%, 33.4%, 35.5%, 45.2%, and 44.4%; at waist level, 44.6%, 56.8%, 64.7%, 71.7%, and 77.2%; and at knee level, 2.2%, 0.0%, 2.2%, 2.8%, and 2.5%. The TFP paper exhibited good radiation-shielding properties against the scattered radiation encountered in clinical settings, and was shown to have potential application in decreasing the radiation exposure to the operator during interventional radiology.


Assuntos
Proteção Radiológica/instrumentação , Radiologia Intervencionista/instrumentação , Tungstênio , Fluoroscopia , Humanos , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista
11.
J Imaging Inform Med ; 37(1): 167-179, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38343219

RESUMO

Deep learning (DL) has recently attracted attention for data processing in positron emission tomography (PET). Attenuation correction (AC) without computed tomography (CT) data is one of the interests. Here, we present, to our knowledge, the first attempt to generate an attenuation map of the human head via Sim2Real DL-based tissue composition estimation from model training using only the simulated PET dataset. The DL model accepts a two-dimensional non-attenuation-corrected PET image as input and outputs a four-channel tissue-composition map of soft tissue, bone, cavity, and background. Then, an attenuation map is generated by a linear combination of the tissue composition maps and, finally, used as input for scatter+random estimation and as an initial estimate for attenuation map reconstruction by the maximum likelihood attenuation correction factor (MLACF), i.e., the DL estimate is refined by the MLACF. Preliminary results using clinical brain PET data showed that the proposed DL model tended to estimate anatomical details inaccurately, especially in the neck-side slices. However, it succeeded in estimating overall anatomical structures, and the PET quantitative accuracy with DL-based AC was comparable to that with CT-based AC. Thus, the proposed DL-based approach combined with the MLACF is also a promising CT-less AC approach.

12.
Kaku Igaku ; 50(1): 1-11, 2013 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-23700819

RESUMO

OBJECTIVE: Working group on JJ1017 nuclear medicine domain extension code in the Japanese Society of Nuclear Medicine has created nuclear medicine extension codes keeping the integrity with JJ1017. The objective of this study was to investigate the usefulness of nuclear medicine extension codes in real clinical settings. METHOD: Nuclear medicine examinations of each institution were extracted from the examination master table and then the target subset of examinations to be coded with JJ1017 were identified. For this subset, working process was conducted, during which the followings compared conformity rate, application rate of representative frequently code set and compliance rate of nuclear medicine extension codes. RESULTS: Without using representative frequently code set, it was difficult to invent the same code for the same examination. By using the representative frequently code set, the same code expression could be invented for the same examination. Furthermore, using nuclear medicine extension codes additionally, these which could not be appropriately coded with representative frequently code set alone. CONCLUSION: Nuclear medicine extension codes keeping the integrity with JJ1017, was proved to be useful to improve the accuracy of coding.


Assuntos
Codificação Clínica , Medicina Nuclear/estatística & dados numéricos , Análise de Variância , Sistemas de Informação Hospitalar/normas , Humanos , Japão , Medicina Nuclear/normas , Compostos Radiofarmacêuticos/normas , Compostos Radiofarmacêuticos/uso terapêutico
13.
Asia Ocean J Nucl Med Biol ; 11(1): 37-43, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36619188

RESUMO

Objectives: We evaluated the relationship between regional accumulations of the tau positron emission tomography (PET) tracer THK5351 and cognitive dysfunction in the Alzheimer's disease (AD) continuum. Methods: The cases of 18 patients with AD or mild cognitive impairment (MCI) due to AD who underwent three-dimensional MRI, fluoro-2-deoxyglucose (FDG)-(PET), Pittsburgh compound B (PiB)-amyloid PET, and THK5351-tau PET were analyzed. Their mean age was 70.6±11.3, their mean Mini-Mental State Examination (MMSE) score was 22.3±6.8, and their mean Alzheimer Disease Assessment Scale-Cognitive Subtest (ADAS) score was 12.5±7.3. To determine the correlation between each patient's four imaging results and their MMSE and ADAS scores, we performed a voxel-wise statistical analysis with statistical parametric mapping (SPM). Results: The SPM analysis showed that the bilateral parietotemporal FDG accumulations and MMSE scores were positively correlated, and the bilateral parietotemporal FDG accumulations were negatively correlated with ADAS scores. There were significant correlations between bilateral parietotemporal and left posterior cingulate/precuneus THK5351 accumulations and MMSE/ADAS scores. Conclusion: In the AD brain, THK5351 correlates with neuropsychological test scores as well as or more additional than FDG due to its affinity for both tau and monoamine oxidase-B (MAO-B), and measurements of THK5351 may thus be useful in estimating the progression of AD.

14.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 79(3): 262-270, 2023 Mar 20.
Artigo em Japonês | MEDLINE | ID: mdl-36696976

RESUMO

PURPOSE: Recently, the targeted radionuclide therapy (TRT) was urgently required to adapt the practice and environment because of the implementation of novel therapeutic radiopharmaceuticals such as alpha- and beta- radionuclides therapy. The present study aimed to clarify the questionnaire survey with the current situation (safety controls for workers and patients) at Japanese TRT facilities. METHODS: The massive questionnaire survey, 2 months from October to November 2021, was conducted among nationwide 251 facilities that have performed TRT in the past two years. The alpha- and beta- therapeutic radiopharmaceuticals were categorized and answered by one representative of the facility under anonymity. We analyzed the actual situation of each facility related to occupational exposure, radiation protection, contamination inspection, patient release criteria, and dosimetry for TRT. RESULTS: The survey response rate was 69.1% (174 facilities). About 75% of these facilities reported that they either follow the guidelines or take their own measures to reduce occupational exposure. The confirmed means of patient release criteria were 68.0% with the administered radioactivity and 87.2% with the ambient dose rate. The cold run was not performed for the first time at 15.0% and 10.0% of the facilities for ß- and α-emitting radionuclides, respectively. The facilities without attachment syringe shields were 39.2% for alpha-radionuclides therapy and 20.3% for beta-radionuclides therapy. CONCLUSION: We clarified the Japanese problem for TRT practice and environment by the questionnaire survey. Our findings indicated that the Japanese guidelines and manuals for TRT were not partly followed in the nationwide facilities.


Assuntos
População do Leste Asiático , Compostos Radiofarmacêuticos , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Radioisótopos/uso terapêutico , Inquéritos e Questionários , Radiometria
15.
J Nucl Med ; 64(1): 153-158, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35798557

RESUMO

We acquired brain 18F-FDG and 18F-flutemetamol PET images using a time-of-flight system dedicated to the head (dhPET) and a conventional whole-body PET/CT (wbPET) system and evaluated the clinical superiority of dhPET over wbPET. Methods: There were 18 subjects for the 18F-FDG PET study and 17 subjects for the 18F-flutemetamol PET study. 18F-FDG PET images were first obtained using wbPET, followed by dhPET. 18F-flutemetamol PET images were first obtained using wbPET, followed by dhPET. Images acquired using dhPET and wbPET were compared by visual inspection, voxelwise analysis, and SUV ratio (SUVR). Results: All 18F-FDG and 18F-flutemetamol images acquired using dhPET were judged as visually better than those acquired using wbPET. The voxelwise analysis demonstrated that accumulations in the cerebellum, in the lateral occipital cortices, and around the central sulcus area in dhPET 18F-FDG images were lower than those in wbPET 18F-FDG images, whereas accumulations around the ventricle systems were higher in dhPET 18F-FDG images than those in wbPET 18F-FDG images. Accumulations in the cerebellar dentate nucleus, in the midbrain, in the lateral occipital cortices, and around the central sulcus area in dhPET images were lower than those in wbPET images, whereas accumulations around the ventricle systems were higher in dhPET 18F-flutemetamol images than those in wbPET 18F-flutemetamol images. The mean cortical SUVRs of 18F-FDG and 18F-flutemetamol dhPET images were significantly higher than those of 18F-FDG and 18F-flutemetamol wbPET images, respectively. Conclusion: The dhPET images had better image quality by visual inspection and higher SUVRs than wbPET images. Although there were several regional accumulation differences between dhPET and wbPET images, understanding this phenomenon will enable full use of the features of this dhPET system in clinical practice.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem
16.
Ann Nucl Med ; 37(9): 494-503, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37243882

RESUMO

OBJECTIVE: Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. METHODS: The activity of 4.0 and 2.0 kBq/mL for Hoffman 3D brain and cylindrical phantoms, respectively, was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in gray (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. RESULTS: Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2-4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner improved contrast and image noise. CONCLUSIONS: The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Encéfalo/diagnóstico por imagem , Imagens de Fantasmas , Padrões de Referência
17.
Diagnostics (Basel) ; 13(6)2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36980385

RESUMO

The performances of photomultiplier tube (PMT)-based dedicated breast positron emission tomography (PET) and silicon photomultiplier tube (SiPM)-based time-of-flight (TOF) PET, which is applicable not only to breast imaging but also to head imaging, were compared using a phantom study. A cylindrical phantom containing four spheres (3-10 mm in diameter) filled with 18F-FDG at two signal-to-background ratios (SBRs), 4:1 and 8:1, was scanned. The phantom images, which were reconstructed using three-dimensional list-mode dynamic row-action maximum likelihood algorithm with various ß-values and post-smoothing filters, were visually and quantitatively compared. Visual evaluation showed that the 3 mm sphere was more clearly visualized with higher ß and smaller post-filters, while the background was noisier; SiPM-based TOF-PET was superior to PMT-based dbPET in sharpness, smoothness, and detectability, although the background was noisier at the SBR of 8:1. Quantitative evaluation revealed that the detection index (DI) and recovery coefficient (CRC) of SiPM-based TOF-PET images were higher than those of PMT-based PET images, despite a higher background coefficient of variation (CVBG). The two organ-specific PET systems showed that a 3 mm lesion in the breast could be visualized at the center of the detector, and there was less noise in the SiPM-based TOF-PET image.

18.
Radiother Oncol ; 180: 109491, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36706956

RESUMO

BACKGROUND AND PURPOSE: In this study, fluoromisonidazole positron emission tomography (F-MISO PET/CT) was used to evaluate tumor hypoxia and re-oxygenation in patients with lung tumors treated with stereotactic body radiation therapy (SBRT). MATERIALS AND METHODS: Patients with T1-2 N0 lung cancer were included in this study. The prescribed dose was 48-52 Gy in four fractions. F-MISO PET/CT was performed twice, before SBRT and 1-3 days after the first irradiation. The maximum standardized uptake value (SUVmax) and tumor/muscle ratio (TMR) were evaluated as indicators of hypoxia. The threshold for hypoxia was defined as a TMR of 1.30 or more. RESULTS: Between 2016 and 2021, 15 patients were included. Pre-treatment tumor hypoxia was observed in nine tumors (60 %). TMR in all six tumors without pre-treatment hypoxia rose after single high-dose irradiation. In contrast, TMR in six of nine tumors with pre-treatment hypoxia dropped after irradiation, suggesting re-oxygenation. Although no local recurrence was noted, regional and/or distant relapses were seen in four patients (27 %). Of these, three had tumors with abnormal F-MISO uptake. The remaining patient had a tumor without signs of hypoxia on pre-treatment PET/CT. The 2-year progression free survival of patients with tumors with and without pre-treatment hypoxia were 30 % and 63 %, respectively (p = 0.319). CONCLUSION: Tumor hypoxia reduced after single high-dose irradiation. Tumor with F-MISO uptake seems to be an unfavorable prognostic factor in lung SBRT.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Radiocirurgia , Hipóxia Tumoral , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Pulmão/patologia , Doses de Radiação , Hipóxia Tumoral/efeitos da radiação , Tomografia por Emissão de Pósitrons , Radiossensibilizantes , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais
19.
Clin Nucl Med ; 47(11): 965-967, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35695726

RESUMO

ABSTRACT: A 20-year-old man had left visual impairment and homonymous hemianopsia. MRI findings suggested enlargement of an optic glioma, because optic glioma was indicated by MRI 14 years earlier without a definite pathological diagnosis. 11 C-methionine (MET) PET showed high uptake in the tumor in the parasellar region. Transnasal endoscopic biopsy was performed, and an inflammatory pseudotumor (IPT) was diagnosed based on histopathological findings. High MET uptake in a parasellar IPT has apparently not been previously reported. Clinicians should be aware of the possibility of high MET uptake in IPT, because this image could provide an interpretation pitfall.


Assuntos
Neoplasias Encefálicas , Granuloma de Células Plasmáticas , Glioma do Nervo Óptico , Adulto , Neoplasias Encefálicas/patologia , Granuloma de Células Plasmáticas/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Metionina , Tomografia por Emissão de Pósitrons/métodos , Racemetionina , Adulto Jovem
20.
Ann Nucl Med ; 36(4): 420-426, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35138565

RESUMO

AIM: The aim of this study was to evaluate an image reconstruction algorithm, including a new maximum-likelihood attenuation correction factor (ML-ACF) for time of flight (TOF) brain positron emission tomography (PET). METHODS: The implemented algorithm combines an ML-ACF method that simultaneously estimates both the emission image and attenuation sinogram from TOF emission data, and a scaling method based on anatomical features. To evaluate the algorithm's quantitative accuracy, three-dimensional brain phantom images were acquired and soft-tissue attenuation coefficients and emission values were analyzed. RESULTS: The heterogeneous distributions of attenuation coefficients in soft tissue, skull, and nasal cavity were sufficiently visualized. The attenuation coefficient of soft tissue remained within 5% of theoretical value. Attenuation-corrected emission showed no lateral differences, and significant differences among soft tissue were within the error range. CONCLUSION: The ML-ACF-based attenuation correction implemented for TOF brain PET worked well and obtained practical levels of accuracy.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Crânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA