1.
Analyst ; 149(3): 735-744, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38189568

RESUMO

Salt cluster ions produced by electrospray ionization are used for mass calibration and fundamental investigations into cluster stability and charge separation processes. However, previous studies have been limited to relatively small clusters owing to the heterogeneity associated with large, multiply-charged clusters that leads to unresolved signals in conventional m/z spectra. Here, charge detection mass spectrometry is used to measure both the mass and charge distributions of positively charged clusters of KCl, CaCl2, and LaCl3 with masses between ∼1 and 10 MDa by dynamically measuring the energy per charge, m/z, charge, and mass of simultaneously trapped individual ions throughout a 1 s trapping time. The extent of remaining hydration on the clusters, determined from the change in the frequency of ion motion with time as a result of residual water loss, follows the order KCl < CaCl2 < LaCl3, and is significantly lower than that of a pure water nanodrop, consistent with tighter water binding to the more highly charged cations in these clusters. The number of ion emission events from these clusters also follows this same trend, indicating that water at the cluster surface facilitates charge loss. A new frequency-based method to determine the magnitude of the charge loss resulting from individual ion emission events clearly resolves losses of +1 and +2 ions. Achieving this individual charge state resolution for ion emission events is an important advance in obtaining information about the late stages of bare gaseous ions formation. Future experiments on more hydrated clusters are expected to lead to a better understanding of ion formation in electrospray ionization.

2.
Anal Chem ; 95(45): 16659-16667, 2023 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-37917546

RESUMO

The ability to determine ion energies in electrostatic ion-trap-based charge detection mass spectrometry (CDMS) experiments is important for the accurate measurement of individual ion m/z, charge, and mass. Dynamic energy measurements throughout the time an ion is trapped take advantage of the relationship between ion energy and the harmonic amplitude ratio (HAR) composed from the fundamental and second harmonic amplitudes in the Fourier transform of the ion signal. This method eliminates the need for energy-filtering optics in CDMS and makes it possible to measure energy lost in collisions and changes in ion masses due to dissociation. However, the accuracy of the energy measurement depends on the signal-to-noise ratio (S/N) of the amplitudes used to determine the HAR. Here, a major improvement to this HAR-based dynamic energy measurement method is achieved using HARs composed of higher-order harmonics in addition to the fundamental and second harmonic to determine ion energies. This combined harmonic amplitude ratios for precision energy refinement (CHARPER) method is applied to the analysis of a 103 nm polystyrene nanoparticle ion (359.7 MDa, m/z = 308,300) and the energy resolution (3140) and effective mass resolution (730) achieved are the best yet demonstrated in electrostatic ion-trap-based CDMS. The CHARPER method applied to an ensemble of several thousand adeno-associated virus ion signals also results in higher mass resolution compared to the basic HAR method, making it possible to resolve additional features in the composite mass histogram.

3.
Anal Chem ; 95(26): 10077-10086, 2023 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-37343124

RESUMO

Ion-ion interactions in charge detection mass spectrometers that use electrostatic traps to measure masses of individual ions have not been reported previously, although ion trajectory simulations have shown that these types of interactions affect ion energies and thereby degrade measurement performance. Here, examples of interactions between simultaneously trapped ions that have masses ranging from ca. 2 to 350 MDa and ca. 100 to 1000 charges are studied in detail using a dynamic measurement method that makes it possible to track the evolution of the mass, charge, and energy of individual ions over their trapping lifetimes. Signals from ions that have similar oscillation frequencies can have overlapping spectral leakage artifacts that result in slightly increased uncertainties in the mass determination, but these effects can be mitigated by the careful choice of parameters used in the short-time Fourier transform analysis. Energy transfers between physically interacting ions are also observed and quantified with individual ion energy measurement resolution as high as ∼950. The mass and charge of interacting ions do not change, and their corresponding measurement uncertainties are equivalent to ions that do not undergo physical interactions. Simultaneous trapping of multiple ions in CDMS can greatly decrease the acquisition time necessary to accumulate a statistically meaningful number of individual ion measurements. These results demonstrate that while ion-ion interactions can occur when multiple ions are trapped, they have negligible effects on mass accuracy when using the dynamic measurement method.

4.
J Am Chem Soc ; 144(51): 23368-23378, 2022 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-36525679

RESUMO

The tobacco mosaic viral capsid protein (TMV) is a frequent target for derivatization for myriad applications, including drug delivery, biosensing, and light harvesting. However, solutions of the stacked disk assembly state of TMV are difficult to characterize quantitatively due to their large size and multiple assembled states. Charge detection mass spectrometry (CDMS) addresses the need to characterize heterogeneous populations of large protein complexes in solution quickly and accurately. Using CDMS, previously unobserved assembly states of TMV, including 16-monomer disks and odd-numbered disk stacks, have been characterized. We additionally employed a peptide-protein conjugation reaction in conjunction with CDMS to demonstrate that modified TMV proteins do not redistribute between disks. Finally, this technique was used to discriminate between protein complexes of near-identical mass but different configurations. We have gained a greater understanding of the behavior of TMV, a protein used across a broad variety of fields and applications, in the solution state.


Assuntos
Vírus do Mosaico do Tabaco , Vírus do Mosaico do Tabaco/química , Proteínas do Capsídeo/química , Fenômenos Químicos
5.
Anal Chem ; 94(33): 11703-11712, 2022 08 23.
Artigo em Inglês | MEDLINE | ID: mdl-35961005

RESUMO

Instrumental resolution of Fourier transform-charge detection mass spectrometry instruments with electrostatic ion trap detection of individual ions depends on the precision with which ion energy is determined. Energy can be selected using ion optic filters or from harmonic amplitude ratios (HARs) that provide Fellgett's advantage and eliminate the necessity of ion transmission loss to improve resolution. Unlike the ion energy-filtering method, the resolution of the HAR method increases with charge (improved S/N) and thus with mass. An analysis of the HAR method with current instrumentation indicates that higher resolution can be obtained with the HAR method than the best resolution demonstrated for instruments with energy-selective optics for ions in the low MDa range and above. However, this gain is typically unrealized because the resolution obtainable with molecular systems in this mass range is limited by sample heterogeneity. This phenomenon is illustrated with both tobacco mosaic virus (0.6-2.7 MDa) and AAV9 (3.7-4.7 MDa) samples where mass spectral resolution is limited by the sample, including salt adducts, and not by instrument resolution. Nevertheless, the ratio of full to empty AAV9 capsids and the included genome mass can be accurately obtained in a few minutes from 1× PBS buffer solution and an elution buffer containing 300+ mM nonvolatile content despite extensive adduction and lower resolution. Empty and full capsids adduct similarly indicating that salts encrust the complexes during late stages of droplet evaporation and that mass shifts can be calibrated in order to obtain accurate analyte masses even from highly salty solutions.


Assuntos
Espectrometria de Massas , Capsídeo , Análise de Fourier , Íons/química , Espectrometria de Massas/métodos , Eletricidade Estática
6.
Anal Chem ; 91(11): 7458-7465, 2019 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-31082222

RESUMO

Applications of charge detection mass spectrometry (CDMS) for measuring the masses of large molecules, macromolecular complexes, and synthetic polymers that are too large or heterogeneous for conventional mass spectrometry measurements are made possible by weighing individual ions in order to avoid interferences between ions. Here, a new multiplexing method that makes it possible to measure the masses of many ions simultaneously in CDMS is demonstrated. Ions with a broad range of kinetic energies are trapped. The energy of each ion is obtained from the ratio of the intensity of the fundamental to the second harmonic frequencies of the periodic trapping motion making it possible to measure both the m/ z and charge of each ion. Because ions with the exact same m/ z but with different energies appear at different frequencies, the probability of ion-ion interference is significantly reduced. We show that the measured mass of a protein complex consisting of 16 protomers, RuBisCO (517 kDa), is not affected by the number of trapped ions with up to 21 ions trapped simultaneously in these experiments. Ion-ion interactions do not affect the ion trapping lifetime up to 1 s, and there is no influence of the number of ions on the measured charge-state distribution of bovine serum albumin (66.5 kDa), indicating that ion-ion interactions do not adversely affect any of these measurements. Over an order of magnitude gain in measurement speed over single ion analysis is demonstrated, and significant additional gains are expected with this multi-ion measurement method.

7.
J Phys Chem A ; 122(47): 9224-9232, 2018 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-30407019

RESUMO

Factors affecting the extrusion of guests from metal ion-capped decamethylcucurbit[5]uril (mc5) molecular container complexes are investigated using both collision-induced dissociation techniques and molecular mechanics simulations. For guests without polar bonds, the extrusion barrier increases with increasing guest volume. This is likely because escape of larger guests requires more displacement of the metal ion caps and, thus, more disruption of the ion-dipole interactions between the ion caps and the electronegative rim oxygens of mc5. However, guests larger than the optimum size for encapsulation displace the ion caps prior to collision-induced dissociation, resulting in less stable complexes and lower dissociation thresholds. The extrusion barriers obtained for guests with polar bonds are smaller than those obtained for similarly sized guests without polar bonds. This is likely because the partial charges on the guest allow electrostatic interactions with the ion cap and rim oxygens of mc5 during extrusion, thus stabilizing the extrusion transition state and reducing the extrusion barrier. Results from this study demonstrate simple principles to consider for designing host-guest complexes with specific guest-loss behaviors. Similar trends are observed between the experimental and computational results, demonstrating that molecular mechanics simulations can be used to approximate the relative stability of mc5 molecular container complexes and likely those of other similar complexes.

8.
Anal Chem ; 89(14): 7701-7708, 2017 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-28621517

RESUMO

The masses and mobilities of single multiply charged ions of cytochrome c, ubiquitin, myoglobin, and bovine serum albumin formed by electrospray ionization are measured using charge detection mass spectrometry (CDMS). Single ions are trapped and repeatedly measured as they oscillate inside an electrostatic ion trap with cone electrodes for up to the maximum trapping time set at 500 ms. The histograms of the many single ion oscillation frequencies have resolved peaks that correspond to the different charge states of each protein. The m/z of each ion is determined from the initial oscillation frequency histogram, and the evolution of the ion energy with time is obtained from the changing frequency. A short-time Fourier transform of the time-domain data indicates that the increase in ion frequency occurs gradually with time with occasional sudden jumps in frequency. The frequency jumps are similar for each protein and may be caused by collision-induced changes in the ion trajectory. The rate of the gradual frequency shift increases with protein mass and charge state. This gradual frequency change is due to ion energy loss from collisions with the background gas. The total energy lost by an ion is determined from the latter frequency shifts normalized to a 500 ms lifetime, and these values increase nearly linearly with measured collisional cross-sections for these protein ions. These results show that the mass and collisional cross-section of single multiply charged ions can be obtained from these CDMS measurements by using proteins with known collisional cross-sections for calibration.


Assuntos
Citocromos c/análise , Mioglobina/análise , Soroalbumina Bovina/análise , Ubiquitina/análise , Animais , Bovinos , Íons/análise , Espectrometria de Massas
9.
Analyst ; 142(15): 2760-2769, 2017 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-28636005

RESUMO

Charge detection mass spectrometry is used to measure the mass, charge, MSn and mobility of an individual ion produced by electrospray ionization of a 8 MDa polyethylene glycol sample. The charge detection mass spectrometer is an electrostatic ion trap that uses cone electrodes and a single tube detector and can detect ions for up to the full trapping time of 4.0 s. The time-domain signal induced on the detector tube by a single multiply charged ion can be complex owing to sequential fragmentation of the original precursor ion as well as increasing oscillation frequencies of the single ion owing to collisions with background gas that reduce the kinetic energy of the ion inside the trap. Simulations show that the ratio of the time for the ion to turn around inside the cone region of the trap to the time for the ion to travel through the detector tube is constant with m/z and increases with the ion energy per charge. By measuring this ratio, the kinetic energy of an ion can be obtained with good precision (∼1%) and this method to measure ion kinetic energies eliminates the necessity of ion energy selection prior to trapping for high precision mass measurement of large molecules in complex mixtures. This method also makes it possible to measure the masses of each sequential fragment ion formed from the original precursor ion. MS7 of a single multiply charged PEG molecule is demonstrated, and from these ion energy measurements and effects of collisions on the ion motion inside the trap, information about the ion mobility of the precursor ion and its fragments is obtained.

10.
ACS Nano ; 2024 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-38913932

RESUMO

A variety of scattering-based, microscopy-based, and mobility-based methods are frequently used to probe the size distributions of colloidal nanoparticles with transmission electron microscopy (TEM) often considered to be the "gold standard". Charge detection mass spectrometry (CDMS) is an alternative method for nanoparticle characterization that can rapidly measure the mass and charge of individual nanoparticle ions with high accuracy. Two low polydispersity, ∼100 nm diameter nanoparticle size standards with different compositions (polymethyl methacrylate/polystyrene copolymer and 100% polystyrene) were characterized using both TEM and CDMS to explore the merits and complementary aspects of both methods. Mass and diameter distributions are rapidly obtained from CDMS measurements of thousands of individual ions of known spherical shape, requiring less time than TEM sample preparation and image analysis. TEM image-to-image variations resulted in a ∼1-2 nm range in the determined mean diameters whereas the CDMS mass precision of ∼1% in these experiments leads to a diameter uncertainty of just 0.3 nm. For the 100% polystyrene nanoparticles with known density, the CDMS and TEM particle diameter distributions were in excellent agreement. For the copolymer nanoparticles with unknown density, the diameter from TEM measurements combined with the mass from CDMS measurements enabled an accurate measurement of nanoparticle density. Differing extents of charging for the two nanoparticle standards measured by CDMS show that charging is sensitive to nanoparticle surface properties. A mixture of the two samples was separated based on their different extents of charging despite having overlapping mass distributions centered at 341.5 and 331.0 MDa.

11.
ACS Cent Sci ; 9(8): 1611-1622, 2023 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-37637724

RESUMO

Fission of micron-size charged droplets has been observed using optical methods, but little is known about fission dynamics and breakup of smaller nanosize droplets that are important in a variety of natural and industrial processes. Here, spontaneous fission of individual aqueous nanodrops formed by electrospray is investigated using charge detection mass spectrometry. Fission processes ranging from formation of just two progeny droplets in 2 ms to production of dozens of progeny droplets over 100+ ms are observed for nanodrops that are charged above the Rayleigh limit. These results indicate that Rayleigh fission is a continuum of processes that produce progeny droplets that vary widely in charge, mass, and number.

12.
J Am Soc Mass Spectrom ; 34(6): 1186-1195, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37249338

RESUMO

Effects of electrospray voltage on cluster size and abundance formed from aqueous CsI were investigated with emitter tip diameters between 260 ± 7 nm and 2.45 ± 0.30 µm. Cluster size increases with increasing voltage, increasing solution concentration and increasing emitter diameter consistent with formation of larger initial droplet sizes. For emitters with tip diameters above ∼1 µm, varying the voltage either up or down leads to reproducible voltage-dependent extents of cluster formation. In contrast, higher voltages with submicron diameter emitters can lead to only Cs+ and Cs(H2O)+ and no clusters. This change in ion formation reproducibly occurs at spray potentials >1.3 kV for 260 nm emitters and appears to be induced by a corona discharge and material build-up at the emitter tip. Under conditions where abundant Cs+ is observed and no clusters are formed, ions such as K+ and Cu1+ are also observed but ions with more negative solvation energies, such as Ba2+, are not. Similarly, ions from bradykinin and ubiquitin are observed predischarge but not post discharge. Ions with more positive solvation energies can desorb directly from the air-water interface that is created at the tip of these emitters, whereas ions with more negative solvation energies as well as peptide and protein ions do not. These results indicate that ion desorption directly from solution can occur, and similar experiments with even smaller emitters may lead to new insights into ion formation in electrospray ionization.

13.
ACS Nano ; 17(8): 7765-7774, 2023 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-37027782

RESUMO

The sizes and shapes of nanoparticles play a critical role in their chemical and material properties. Common sizing methods based on light scattering or mobility lack individual particle specificity, and microscopy-based methods often require cumbersome sample preparation and image analysis. A promising alternative method for the rapid and accurate characterization of nanoparticle size is charge detection mass spectrometry (CDMS), an emerging technique that measures the masses of individual ions. A recently constructed CDMS instrument designed specifically for high acquisition speed, efficiency, and accuracy is described. This instrument does not rely on an ion energy filter or estimates of ion energy that have been previously required for mass determination, but instead uses direct, in situ measurements. A standardized sample of ∼100 nm diameter polystyrene nanoparticles and ∼50 nm polystyrene nanoparticles with amine-functionalized surfaces are characterized using CDMS and transmission electron microscopy (TEM). Individual nanoparticle masses measured by CDMS are transformed to diameters, and these size distributions are in close agreement with distributions measured by TEM. CDMS analysis also reveals dimerization of ∼100 nm nanoparticles in solution that cannot be determined by TEM due to the tendency of nanoparticles to agglomerate when dried onto a surface. Comparing the acquisition and analysis times of CDMS and TEM shows particle sizing rates up to ∼80× faster are possible using CDMS, even when samples ∼50× more dilute were used. The combination of both high-accuracy individual nanoparticle measurements and fast acquisition rates by CDMS represents an important advance in nanoparticle analysis capabilities.

14.
J Am Soc Mass Spectrom ; 33(11): 2129-2137, 2022 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-36173188

RESUMO

Short-time Fourier transforms with short segment lengths are typically used to analyze single ion charge detection mass spectrometry (CDMS) data either to overcome effects of frequency shifts that may occur during the trapping period or to more precisely determine the time at which an ion changes mass or charge, or enters an unstable orbit. The short segment lengths can lead to scalloping loss unless a large number of zero-fills are used, making computational time a significant factor in real-time analysis of data. Apodization specific fitting leads to a 9-fold reduction in computation time compared to zero-filling to a similar extent of accuracy. This makes possible real-time data analysis using a standard desktop computer. Rectangular apodization leads to higher resolution than the more commonly used Gaussian or Hann apodization and makes it possible to separate ions with similar frequencies, a significant advantage for experiments in which the masses of many individual ions are measured simultaneously. Equally important is a >20% increase in S/N obtained with rectangular apodization compared to Gaussian or Hann, which directly translates to a corresponding improvement in accuracy of both charge measurements and ion energy measurements that rely on the amplitudes of the fundamental and harmonic frequencies. Combined with computing the fast Fourier transform in a lower-level language, this fitting procedure eliminates computational barriers and should enable real-time processing of CDMS data on a laptop computer.


Assuntos
Análise de Dados , Análise de Fourier , Espectrometria de Massas/métodos , Íons/química
15.
Chem Sci ; 12(14): 5185-5195, 2021 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-34168773

RESUMO

Mechanistic information about how gaseous ions are formed from charged droplets has been difficult to establish because direct observation of nanodrops in a size range relevant to gaseous macromolecular ion formation by optical or traditional mass spectrometry methods is challenging owing to their small size and heterogeneity. Here, the mass and charge of individual aqueous nanodrops between 1-10 MDa (15-32 nm diameter) with ∼50-300 charges are dynamically monitored for 1 s using charge detection mass spectrometry. Discrete losses of minimally solvated singly charged ions occur, marking the first direct observation of ion emission from aqueous nanodrops in late stages of droplet evaporation relevant to macromolecular ion formation in native mass spectrometry. Nanodrop charge depends on the identity of constituent ions, with pure water nanodrops charged slightly above the Rayleigh limit and aqueous solutions containing alkali metal ions charged progressively below the Rayleigh limit with increasing cation size. MS2 capsid ions (∼3.5 MDa; ∼27 nm diameter) are more highly charged from aqueous ammonium acetate than from its biochemically preferred, 100 mM NaCl/10 mM Na phosphate solution, consistent with ion emission reducing the nanodrop and resulting capsid charge. The extent of charging indicates that the capsid partially collapses inside the nanodrops prior to the charging and formation of the dehydrated gaseous ions. These results demonstrate that ion emission can affect macromolecular charging and that conformational changes to macromolecular structure can occur in nanodrops prior to the formation of naked gaseous ions.

16.
J Am Soc Mass Spectrom ; 30(12): 2637-2645, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31720975

RESUMO

Weighing single ions with charge detection mass spectrometry (CDMS) makes it possible to obtain the masses of molecules of essentially unlimited size even in highly heterogeneous samples, but producing a mass histogram that is representative of all of the components in a mixture requires substantial measurement time. Multiple ions can be trapped to reduce analysis time but ion signals can overlap. To determine the maximum gains in analysis speed possible with current instrumentation with multiple ion trapping, simulations calculating the frequency and overlap rate of ions with different mass, charge, and energy ranges were performed. For an analyte with a broad mass distribution, such as long chain polyethylene glycol (PEG, 8 MDa), gains in analysis speed of up to 160 times that of prior CDMS experiments are possible. For signals from homogeneous samples, ions with the same m/z have frequencies that overlap and interfere, reducing the effectiveness of multiplexing in experiments where ions have the same energy per charge. We show that by maximizing the decoupling of ion m/z from frequency using a broad range of ion energies, the rate of signal overlap is significantly reduced making it possible to trap more ions. Under optimum decoupling conditions, a measurement speed nearly 50 times greater than that of prior CDMS experiments is possible for RuBisCO (517 kDa). The reduction in overlap due to decoupling also results in more accurate quantitation in samples that contain multiple analytes with different concentrations.

17.
J Am Soc Mass Spectrom ; 30(6): 946-955, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30430436

RESUMO

A method to correct for the effect of ion energy on charge measurements of individual ions trapped and weighed with charge detection mass spectrometry (CDMS) is demonstrated. Ions with different energies induce different signal patterns inside an electrostatic ion trap. The sum of the amplitudes of the fundamental and second harmonic frequencies in the Fourier transform of the induced signal, which has been used to obtain the ion charge, depends on both ion energy and charge. The amplitudes of the fundamental frequencies of ions increase over time as ions lose energy by collisions with background gas and solvent loss from larger ions. Model ion signals are simulated with the same time-domain amplitude at different energies and frequencies and the resulting fundamental frequency amplitudes are used to normalize real ion signals for energy and frequency effects. The fundamental frequency amplitude decreases dramatically below 20 kHz and increases by ~ 17% from the highest energy to lowest energy that is stable with a given trap potential at all frequencies. Normalizing the fundamental frequency amplitude with the modeled amplitudes removes the systematic changes in the charge measurement of polyethylene glycol (PEG) and other ions and makes it possible to signal average the amplitude over long times, which reduces the charge uncertainty to 0.04% for a PEG ion for a 500-ms measurement. This method improves charge measurement accuracy and uncertainty, which are important for high-accuracy mass measurement with CDMS. Graphical abstract ᅟ.

18.
J Am Soc Mass Spectrom ; 29(9): 1861-1869, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29860679

RESUMO

A general method for in situ measurements of the energy of individual ions trapped and weighed using charge detection mass spectrometry (CDMS) is described. Highly charged (> 300 e), individual polyethylene glycol (PEG) ions are trapped and oscillate within an electrostatic trap, producing a time domain signal. A segmented Fourier transform (FT) of this signal yields the temporal evolution of the fundamental and harmonic frequencies of ion motion throughout the 500-ms trap time. The ratio of the fundamental frequency and second harmonic (HAR) depends on the ion energy, which is an essential parameter for measuring ion mass in CDMS. This relationship is calibrated using simulated ion signals, and the calibration is compared to the HAR values measured for PEG ion signals where the ion energy was also determined using an independent method that requires that the ions be highly charged (> 300 e). The mean error of 0.6% between the two measurements indicates that the HAR method is an accurate means of ion energy determination that does not depend on ion size or charge. The HAR is determined dynamically over the entire trapping period, making it possible to observe the change in ion energy that takes place as solvent evaporates from the ion and collisions with background gas occur. This method makes it possible to measure mass changes, either from solvent evaporation or from molecular fragmentation (MSn), as well as the cross sections of ions measured using CDMS. Graphical Abstract.