RESUMO
AIMS: This study aims to identify and visualize electrocardiogram (ECG) features using an explainable deep learning-based algorithm to predict cardiac resynchronization therapy (CRT) outcome. Its performance is compared with current guideline ECG criteria and QRSAREA. METHODS AND RESULTS: A deep learning algorithm, trained on 1.1 million ECGs from 251 473 patients, was used to compress the median beat ECG, thereby summarizing most ECG features into only 21 explainable factors (FactorECG). Pre-implantation ECGs of 1306 CRT patients from three academic centres were converted into their respective FactorECG. FactorECG predicted the combined clinical endpoint of death, left ventricular assist device, or heart transplantation [c-statistic 0.69, 95% confidence interval (CI) 0.66-0.72], significantly outperforming QRSAREA and guideline ECG criteria [c-statistic 0.61 (95% CI 0.58-0.64) and 0.57 (95% CI 0.54-0.60), P < 0.001 for both]. The addition of 13 clinical variables was of limited added value for the FactorECG model when compared with QRSAREA (Δ c-statistic 0.03 vs. 0.10). FactorECG identified inferolateral T-wave inversion, smaller right precordial S- and T-wave amplitude, ventricular rate, and increased PR interval and P-wave duration to be important predictors for poor outcome. An online visualization tool was created to provide interactive visualizations (https://crt.ecgx.ai). CONCLUSION: Requiring only a standard 12-lead ECG, FactorECG held superior discriminative ability for the prediction of clinical outcome when compared with guideline criteria and QRSAREA, without requiring additional clinical variables. End-to-end automated visualization of ECG features allows for an explainable algorithm, which may facilitate rapid uptake of this personalized decision-making tool in CRT.
Assuntos
Terapia de Ressincronização Cardíaca , Aprendizado Profundo , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Resultado do Tratamento , Eletrocardiografia , Arritmias Cardíacas/terapiaRESUMO
BACKGROUND: Idiopathic ventricular fibrillation (iVF) is a rare cause of sudden cardiac arrest and, by definition, a diagnosis of exclusion. Due to the rarity of the disease, previous and current studies are limited by their retrospective design and small patient numbers. Even though the incidence of iVF has declined owing to the identification of new disease entities, an important subgroup of patients remains. AIM: To expand the existing Dutch iVF Registry into a large nationwide cohort of patients initially diagnosed with iVF, to reveal the underlying cause of iVF in these patients, and to improve arrhythmia management. METHODS: The Dutch iVF Registry includes sudden cardiac arrest survivors with an initial diagnosis of iVF. Clinical data and outcomes are collected. Outcomes include subsequent detection of a diagnosis other than 'idiopathic', arrhythmia recurrence and death. Non-invasive electrocardiographic imaging is used to investigate electropathological substrates and triggers of VF. RESULTS: To date, 432 patients have been included in the registry (median age at event 40 years (interquartile range 28-52)), 61% male. During a median follow-up of 6 (2-12) years, 38 patients (9%) received a diagnosis other than 'idiopathic'. Eleven iVF patients were characterised with electrocardiographic imaging. CONCLUSION: The Dutch iVF Registry is currently the largest of its kind worldwide. In this heterogeneous population of index patients, we aim to identify common functional denominators associated with iVF. With the implementation of non-invasive electrocardiographic imaging and other diagnostic modalities (e.g. echocardiographic deformation, cardiac magnetic resonance), we advance the possibilities to reveal pro-fibrillatory substrates.
RESUMO
AIMS: During the diagnostic work-up of patients with idiopathic ventricular fibrillation (VF), next-generation sequencing panels can be considered to identify genotypes associated with arrhythmias. However, consensus for gene panel testing is still lacking, and variants of uncertain significance (VUS) are often identified. The aim of this study was to evaluate genetic testing and its results in idiopathic VF patients. METHODS AND RESULTS: We investigated 419 patients with available medical records from the Dutch Idiopathic VF Registry. Genetic testing was performed in 379 (91%) patients [median age at event 39 years (27-51), 60% male]. Single-gene testing was performed in 87 patients (23%) and was initiated more often in patients with idiopathic VF before 2010. Panel testing was performed in 292 patients (77%). The majority of causal (likely) pathogenic variants (LP/P, n = 56, 15%) entailed the DPP6 risk haplotype (n = 39, 70%). Moreover, 10 LP/P variants were found in cardiomyopathy genes (FLNC, MYL2, MYH7, PLN (two), TTN (four), RBM20), and 7 LP/P variants were identified in genes associated with cardiac arrhythmias (KCNQ1, SCN5A (2), RYR2 (four)). For eight patients (2%), identification of an LP/P variant resulted in a change of diagnosis. In 113 patients (30%), a VUS was identified. Broad panel testing resulted in a higher incidence of VUS in comparison to single-gene testing (38% vs. 3%, P < 0.001). CONCLUSION: Almost all patients from the registry underwent, albeit not broad, genetic testing. The genetic yield of causal LP/P variants in idiopathic VF patients is 5%, increasing to 15% when including DPP6. In specific cases, the LP/P variant is the underlying diagnosis. A gene panel specifically for idiopathic VF patients is proposed.
Assuntos
Arritmias Cardíacas , Fibrilação Ventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/genética , Fibrilação Ventricular/epidemiologia , Arritmias Cardíacas/genética , Testes GenéticosRESUMO
The EU Horizon 2020 Framework-funded Standardized Treatment and Outcome Platform for Stereotactic Therapy Of Re-entrant tachycardia by a Multidisciplinary (STOPSTORM) consortium has been established as a large research network for investigating STereotactic Arrhythmia Radioablation (STAR) for ventricular tachycardia (VT). The aim is to provide a pooled treatment database to evaluate patterns of practice and outcomes of STAR and finally to harmonize STAR within Europe. The consortium comprises 31 clinical and research institutions. The project is divided into nine work packages (WPs): (i) observational cohort; (ii) standardization and harmonization of target delineation; (iii) harmonized prospective cohort; (iv) quality assurance (QA); (v) analysis and evaluation; (vi, ix) ethics and regulations; and (vii, viii) project coordination and dissemination. To provide a review of current clinical STAR practice in Europe, a comprehensive questionnaire was performed at project start. The STOPSTORM Institutions' experience in VT catheter ablation (83% ≥ 20 ann.) and stereotactic body radiotherapy (59% > 200 ann.) was adequate, and 84 STAR treatments were performed until project launch, while 8/22 centres already recruited VT patients in national clinical trials. The majority currently base their target definition on mapping during VT (96%) and/or pace mapping (75%), reduced voltage areas (63%), or late ventricular potentials (75%) during sinus rhythm. The majority currently apply a single-fraction dose of 25 Gy while planning techniques and dose prescription methods vary greatly. The current clinical STAR practice in the STOPSTORM consortium highlights potential areas of optimization and harmonization for substrate mapping, target delineation, motion management, dosimetry, and QA, which will be addressed in the various WPs.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Estudos Prospectivos , Arritmias Cardíacas , Ventrículos do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do TratamentoRESUMO
Deterioration of atrial fibrillation into ventricular fibrillation has frequently been described in patients with pre-excitation of the ventricles. We report two cases of atrial fibrillation without pre-excitation leading to rapid ventricular tachycardias and recurrent implantable cardioverter defibrillator therapy in young idiopathic ventricular fibrillation patients.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia Ventricular , Humanos , Nó Atrioventricular/cirurgia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , EletrocardiografiaRESUMO
BACKGROUND: The genetic risk haplotype DPP6 has been linked to familial idiopathic ventricular fibrillation (IVF), but the associated long-term outcomes are unknown. METHODS: DPP6 risk haplotype-positive family members (DPP6 cases) and their risk haplotype-negative relatives (DPP6 controls) were included. Clinical follow-up data were collected through March 2023. Implantable cardioverter-defibrillator (ICD) indication was divided in primary or secondary prevention. Cumulative survival and event rates were calculated. RESULTS: We included 327 DPP6 cases and 315 DPP6 controls. Median follow-up time was 9 years (interquartile range: 4-12). Of the DPP6 cases, 129 (39%) reached the composite endpoint of appropriate ICD shock, sudden cardiac arrest or death, at a median age of 45 years (range: 15-97). Median overall survival was 83 years and 87 years for DPP6 cases and DPP6 controls, respectively (pâ¯< 0.001). In DPP6 cases, median overall survival was shorter for males (74 years) than females (85 years) (pâ¯< 0.001). Of the DPP6 cases, 97 (30%) died, at a median age of 50 years. With a prophylactic ICD implantation advise based on risk haplotype, sex and age, 137 (42%) of DPP6 cases received an ICD, for primary prevention (nâ¯= 109) or secondary prevention (nâ¯= 28). In the primary prevention subgroup, 10 patients experienced a total of 34 appropriate ICD shocks, and there were no deaths during follow-up. DPP6 cases with a secondary prevention ICD experienced a total of 231 appropriate ICD shocks. CONCLUSION: Patients with the DPP6 risk haplotype, particularly males, are at an increased risk of IVF and sudden cardiac death. Using a risk stratification approach based on risk haplotype, sex and age, a substantial proportion of patients with a primary prevention ICD experienced appropriate ICD shocks, showing the benefit of prophylactic ICD implantation with this strategy.
RESUMO
BACKGROUND: Persistent phrenic nerve palsy (PNP) is an established complication of atrial fibrillation (AF) ablation, especially during cryoballoon and thoracoscopic ablation. Data on persistent PNP reversibility is limited because most patients recover <24 h. This study aims to investigate persistent PNP recovery, freedom of PNP-related symptoms after AF ablation and identify baseline variables associated with the occurrence and early PNP recovery in a large nationwide registry study. METHODS: In this study, we used data from the Netherlands Heart Registration, comprising data from 9549 catheter and thoracoscopic AF ablations performed in 2016 and 2017. PNP data was available of 7433 procedures, and additional follow-up data were collected for patients who developed persistent PNP. RESULTS: Overall, the mean age was 62 ± 10 years, and 67.7% were male. Fifty-four (0.7%) patients developed persistent PNP and follow-up was available in 44 (81.5%) patients. PNP incidence was 0.07%, 0.29%, 1.41%, and 1.25%, respectively for patients treated with conventional-RF, phased-RF, cryoballoon, and thoracoscopic ablation respectively. Seventy-one percent of the patients fully recovered, and 86% were free of PNP-related symptoms after a median follow-up of 203 (113-351) and 184 (82-359) days, respectively. Female sex, cryoballoon, and thoracoscopic ablation were associated with a higher risk to develop PNP. Patients with PNP recovering ≤180 days had a larger left atrium volume index than those with late or no recovery. CONCLUSION: After AF ablation, persistent PNP recovers in the majority of patients, and most are free of symptoms. Female patients and patients treated with cryoballoon or thoracoscopic ablation are more prone to develop PNP.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Paralisia/etiologia , Nervo Frênico , Veias Pulmonares/cirurgia , Resultado do TratamentoRESUMO
AIMS: While electrocardiogram (ECG) characteristics have been associated with life-threatening ventricular arrhythmias (LTVA) in dilated cardiomyopathy (DCM), they typically rely on human-derived parameters. Deep neural networks (DNNs) can discover complex ECG patterns, but the interpretation is hampered by their 'black-box' characteristics. We aimed to detect DCM patients at risk of LTVA using an inherently explainable DNN. METHODS AND RESULTS: In this two-phase study, we first developed a variational autoencoder DNN on more than 1 million 12-lead median beat ECGs, compressing the ECG into 21 different factors (F): FactorECG. Next, we used two cohorts with a combined total of 695 DCM patients and entered these factors in a Cox regression for the composite LTVA outcome, which was defined as sudden cardiac arrest, spontaneous sustained ventricular tachycardia, or implantable cardioverter-defibrillator treated ventricular arrhythmia. Most patients were male (n = 442, 64%) with a median age of 54 years [interquartile range (IQR) 44-62], and median left ventricular ejection fraction of 30% (IQR 23-39). A total of 115 patients (16.5%) reached the study outcome. Factors F8 (prolonged PR-interval and P-wave duration, P < 0.005), F15 (reduced P-wave height, P = 0.04), F25 (increased right bundle branch delay, P = 0.02), F27 (P-wave axis P < 0.005), and F32 (reduced QRS-T voltages P = 0.03) were significantly associated with LTVA. CONCLUSION: Inherently explainable DNNs can detect patients at risk of LTVA which is mainly driven by P-wave abnormalities.
Assuntos
Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/diagnóstico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Fatores de Risco , Volume Sistólico , Função Ventricular Esquerda/fisiologiaRESUMO
INTRODUCTION: The benefit of implantable cardioverter-defibrillator (ICD) implantation in patients with hemodynamically not tolerated ventricular tachycardia (VT) and midrange reduced to normal ejection fraction (LVEF >35%) is currently unclear. The purpose of this study was to investigate follow-up after hemodynamically not tolerated VT in patients with LVEF >35%. In addition, we aimed to find possible predictive factors to identify who will benefit from ICD implantation. METHODS: In a retrospective single-centre case series, all patients with hemodynamically not tolerated VT and LVEF >35% that underwent electrophysiological study (EPS) and/or radiofrequency VT ablation were included. RESULTS: Forty-two patients (5 women, median age 68 years) with hemodynamically not tolerated VT and LVEF >35% underwent EPS. VT ablation was performed in thirty-one patients, which was considered successful in twenty-three patients. Nineteen patients had an ICD at discharge while 23 patients were discharged without an ICD. The severity of hemodynamic compromise, LVEF and ablation success played an important role in the decision-making for ICD implantation. Six patients (14.3%) had recurrence of VT, all hemodynamically tolerated. CONCLUSIONS: In this small case series, patients with hemodynamically not tolerated VT and LVEF >35% had a relatively low recurrence rate and all recurrences were nonfatal. Based on our results, we hypothesize that the severity of hemodynamic compromise, LVEF and ablation success might modify the risk for VA recurrence. A prospective study to determine the prognostic value of these factors in patients with hemodynamically not tolerated VT and LVEF >35% is necessary.
Assuntos
Cardiomiopatias/fisiopatologia , Doença das Coronárias/fisiopatologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ablação por Radiofrequência , Volume Sistólico/fisiologia , Taquicardia Ventricular/cirurgia , Idoso , Cardiomiopatias/complicações , Doença das Coronárias/complicações , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Taquicardia Ventricular/complicações , Taquicardia Ventricular/fisiopatologia , Resultado do TratamentoRESUMO
AIMS: Pulmonary vein isolation (PVI) has become a cornerstone of the invasive treatment of atrial fibrillation. Severe complications are reported in 1-3% of patients. This study aims to compare complications and follow-up outcome of PVI in patients with atrial fibrillation. METHODS AND RESULTS: The data were extracted from the Netherlands Heart Registration. Procedural and follow-up outcomes in patients treated with conventional radiofrequency (C-RF), multielectrode phased RF (Ph-RF), or cryoballoon (CB) ablation from 2012 to 2017 were compared. Subgroup analysis was performed to identify variables associated with complications and repeat ablations. In total, 13 823 patients (69% male) were included. The reported complication incidence was 3.6%. Patients treated with C-RF developed more cardiac tamponades (C-RF 0.8% vs. Ph-RF 0.3% vs. CB 0.3%, P ≤ 0.001) and vascular complications (C-RF 1.7% vs. Ph-RF 1.2% vs. CB 1.3%, P ≤ 0.001). Ph-RF was associated with fewer bleeding complications (C-RF: 1.0% vs. Ph-RF: 0.4% vs. CB: 0.7%, P = 0.020). Phrenic nerve palsy mainly occurred in patients treated with CB (C-RF: 0.1% vs. Ph-RF: 0.2% vs. CB: 1.5%, P ≤ 0.001). In total, 18.4% of patients were referred for repeat ablation within 1 year. Female sex, age, and CHA2DS2-VASc were independent risk factors for cardiac tamponade and bleeding complications, with an adjusted OR for female patients of 2.97 (95% CI 1.98-4.45) and 2.02 (95% CI 1.03-4.00) respectively. CONCLUSION: The reported complication rate during PVI was low. Patients treated with C-RF ablation were more likely to develop cardiac tamponades and vascular complications. Female sex was associated with more cardiac tamponade and bleeding complications.
Assuntos
Técnicas de Ablação , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Países Baixos/epidemiologia , Veias Pulmonares/cirurgia , Recidiva , Resultado do TratamentoRESUMO
AIMS: Idiopathic ventricular fibrillation (IVF) is a rare cause of sudden cardiac arrest. Implantable cardioverter-defibrillator (ICD) implantation is currently the only treatment option. Limited data are available on the prevalence and complications of ICD therapy in these patients. We sought to investigate ICD therapy and its complications in patients with IVF. METHODS AND RESULTS: Patients were selected from a national registry of IVF patients. Patients in whom no underlying diagnosis was found during follow-up were eligible for inclusion. Recurrence of ventricular arrhythmia (VA) was derived from medical and ICD records, electrogram records of ICD therapies were used to differentiate between appropriate or inappropriate interventions. Independent predictors for appropriate ICD shock were calculated using cox regression. In 217 IVF patients, recurrence of sustained VAs occurred in 66 patients (30%) during a median follow-up period of 6.1 years. Ten patients died (4.6%). Thirty-eight patients (17.5%) experienced inappropriate ICD therapy, and 32 patients (14.7%) had device-related complications. Symptoms before cardiac arrest [hazard ratio (HR): 2.51, 95% confidence interval (CI): 1.48-4.24], signs of conduction disease (HR: 2.27, 95% CI: 1.15-4.47), and carrier of the DPP6 risk haplotype (HR: 3.24, 1.70-6.17) were identified as independent predictors of appropriate shock occurrence. CONCLUSION: Implantable cardioverter-defibrillator therapy is an effective treatment in IVF, treating recurrences of potentially lethal VAs in approximately one-third of patients during long-term follow-up. However, device-related complications and inappropriate shocks were also frequent. We found significant predictors for appropriate ICD therapy. This may imply that these patients require additional management to prevent recurrent events.
Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Taquicardia Ventricular/terapia , Adulto , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Resultado do TratamentoRESUMO
AIMS: Adenosine testing can reveal dormant pulmonary vein (PV) conduction after PV antrum isolation (PVAI). However, the optimal timing for adenosine administration is unknown. We hypothesized that adenosine testing immediately after PVAI reliably reveals PV reconnection and thereby eliminates the need for an observation period. METHODS AND RESULTS: Fifty patients underwent PVAI. Immediately after isolation of a PV pair, adenosine was administered. Both PV pairs were separately tested. If adenosine restored PV conduction, PVs were re-isolated. During a ≥30 min observation period after immediate adenosine-guided isolation, spontaneous reconnection was assessed and reconnected PVs were re-isolated. After the observation period, adenosine testing was repeated. Immediate adenosine testing revealed dormant conduction in 10.4% of the left PVs and 16.3% of the right PVs. All PVs were successfully re-isolated. During a mean observation period of 36 ± 10 min, spontaneous reconnection occurred in 8.2% of the left and 16.3% of the right PVs. None of these PVs had shown reconnection during immediate testing. Late adenosine testing revealed dormant conduction in 12.5% of the left and 16.3% of the right PVs. In patients without reconnection during immediate adenosine testing, 14.6% of the left PVs and 30.6% of the right PVs showed either spontaneous reconnection or restored PV conduction during late adenosine testing. CONCLUSION: Adenosine testing immediately after PVAI does not reliably exclude later spontaneous or adenosine-induced PV reconnection. Adenosine testing should be performed after an appropriate observation period to reduce risk of PV reconnection.
Assuntos
Adenosina/administração & dosagem , Fibrilação Atrial/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Reprodutibilidade dos Testes , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Idiopathic ventricular fibrillation (iVF) is diagnosed in cardiac arrest survivors without an identifiable cause. Data regarding the health-related quality of life (HRQoL) in iVF patients are lacking. The purpose of this study was to investigate the HRQoL of iVF patients and to compare it to patients with an implantable cardioverter defibrillator (ICD) diagnosed with an underlying disease and healthy subjects. METHODS: In 61 iVF patients with an ICD (iVF-ICD) and 59 ICD patients with a diagnosis (diagnosis-ICD), HRQoL was assessed using the 12-item Short-Form Health Survey (SF-12), the EuroQoL-5 dimensions (EQ-5D), the 9-item Patient Health Questionnaire, and the ICD Patient Concerns (ICDC) Questionnaire. In addition, 860 healthy subjects completed the SF-12. RESULTS: IVF-ICD showed similar SF-12 physical summary scores compared with diagnosis-ICD patients (50.8 [interquartile range (IQR) = 42.1-53.9] vs 54.1 [IQR = 46.5-58.3]; P = 0.080) and healthy subjects (51.8 [IQR = 45.9-54.1]; P = 0.691). The mental summary score was impaired in iVF-ICD patients compared with diagnosis-ICD patients (45.9 [IQR = 40.7-49.4] vs 54.6 [IQR = 46.0-57.9]; P < 0.001) and healthy subjects (47.7 [IQR = 43.0-50.4]; P = 0.027). Scores on all five EQ-5D domains were similar between iVF-ICD patients and diagnosis-ICD patients, as well as symptoms of severe depression (19% vs 12%; P = 0.101). ICD concerns were similar between iVF-ICD and diagnosis-ICD patients (ICDC-scores 2 vs 2; P = 0.494). CONCLUSIONS: Data suggest that there is a reduced mental HRQoL in patients with iVF compared to other cardiac arrest survivors. Screening and treatment of psychological distress should therefore be considered in iVF patients.
Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Depressão/epidemiologia , Cardioversão Elétrica/psicologia , Cardioversão Elétrica/estatística & dados numéricos , Qualidade de Vida/psicologia , Fibrilação Ventricular/prevenção & controle , Fibrilação Ventricular/psicologia , Adulto , Idoso , Causalidade , Comorbidade , Efeitos Psicossociais da Doença , Depressão/psicologia , Feminino , Humanos , Masculino , Saúde Mental/estatística & dados numéricos , Pessoa de Meia-Idade , Países Baixos/epidemiologia , Prevalência , Fatores de Risco , Resultado do Tratamento , Fibrilação Ventricular/epidemiologiaRESUMO
AIMS: Pulmonary vein antrum isolation (PVAI) is the cornerstone of atrial fibrillation (AF) ablation. There is an ongoing discussion on whether and when to add substrate modification to PVAI. This study evaluates (1) long-term efficacy of PVAI as a primary ablation strategy in all patients independently from AF type and (2) predictors of arrhythmia recurrence. METHODS AND RESULTS: A total of 509 consecutive patients (mean age 57 years, 38.9% non-paroxysmal AF) with AF underwent PVAI. In redo procedures, ablation was restricted to re-pulmonary vein (PV) isolation in case of PV reconnection. If the PVs were found to be isolated, substrate modification was performed. In total, 774 procedures were performed. Mean follow-up duration after the first and last ablation was, respectively, 66 ± 23 and 55 ± 25 months. A single PVAI was sufficient in restoring and maintaining long-term sinus rhythm in 41.3% (n = 210) of patients. Multiple procedures (mean 1.5) with re-PV isolation increased long-term success to 58.3% (n = 297). Additional substrate modification (n = 70) increased success to 62.5% (n = 318). After the last ablation, 87.5% of patients experienced success or significant clinical improvement on or off antiarrhythmic drugs. The incidence of left-sided atrial flutter or atrial tachycardia was 5% after PVAI and increased to 32% after additional substrate modification. Independent predictors for arrhythmia recurrence after the last ablation were non-paroxysmal AF, female sex, body mass index, hypertension, and AF duration. CONCLUSION: Five-year freedom of atrial tachyarrhythmia could be achieved by PVAI as primary ablation strategy in 58.3% of patients. Additional substrate modification only moderately increased overall success.
Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Modelos de Riscos Proporcionais , Veias Pulmonares/fisiopatologia , Recidiva , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
Aims: Expert knowledge to correctly interpret electrocardiograms (ECGs) is not always readily available. An artificial intelligence (AI)-based triage algorithm (DELTAnet), able to support physicians in ECG prioritization, could help reduce current logistic burden of overreading ECGs and improve time to treatment for acute and life-threatening disorders. However, the effect of clinical implementation of such AI algorithms is rarely investigated. Methods and results: Adult patients at non-cardiology departments who underwent ECG testing as a part of routine clinical care were included in this prospective cohort study. DELTAnet was used to classify 12-lead ECGs into one of the following triage classes: normal, abnormal not acute, subacute, and acute. Performance was compared with triage classes based on the final clinical diagnosis. Moreover, the associations between predicted classes and clinical outcomes were investigated. A total of 1061 patients and ECGs were included. Performance was good with a mean concordance statistic of 0.96 (95% confidence interval 0.95-0.97) when comparing DELTAnet with the clinical triage classes. Moreover, zero ECGs that required a change in policy or referral to the cardiologist were missed and there was a limited number of cases predicted as acute that did not require follow-up (2.6%). Conclusion: This study is the first to prospectively investigate the impact of clinical implementation of an ECG-based AI triage algorithm. It shows that DELTAnet is efficacious and safe to be used in clinical practice for triage of 12-lead ECGs in non-cardiology hospital departments.
RESUMO
BACKGROUND: Current cohorts of patients with idiopathic ventricular fibrillation (IVF) primarily include adult-onset patients. Underlying causes of sudden cardiac arrest vary with age; therefore, underlying causes and disease course may differ for adolescent-onset vs adult-onset patients. OBJECTIVE: The purpose of this study was to compare adolescent-onset with adult-onset patients having an initially unexplained cause of VF. METHODS: The study included 39 patients with an index event aged ≤19 years (adolescent-onset) and 417 adult-onset patients from the Dutch Idiopathic VF Registry. Data on event circumstances, clinical characteristics, change in diagnosis, and arrhythmia recurrences were collected and compared between the 2 groups. RESULTS: In total, 42 patients received an underlying diagnosis during follow-up (median 7 [2-12] years), with similar yields (15% adolescent-onset vs 9% adult-onset; P = .16). Among the remaining unexplained patients, adolescent-onset patients (n = 33) had their index event at a median age of 17 [16-18] years, and 72% were male. The youngest patient was aged 13 years. In comparison with adults (n = 381), adolescent-onset patients more often had their index event during exercise (P <.01). Adolescent-onset patients experienced more appropriate implantable cardioverter-defibrillator (ICD) therapy during follow-up compared with adults (44% vs 26%; P = .03). Inappropriate ICD therapy (26% vs 17%; P = .19), ICD complications (19% vs 14%; P = .41), and deaths (3% vs 4%; P = 1) did not significantly differ between adolescent-onset and adult-onset patients. CONCLUSION: IVF may occur during adolescence. Adolescent-onset patients more often present during exercise compared with adults. Furthermore, they are more vulnerable to ventricular arrhythmias as reflected by a higher incidence of appropriate ICD therapy.
Assuntos
Idade de Início , Sistema de Registros , Fibrilação Ventricular , Humanos , Masculino , Feminino , Adolescente , Países Baixos/epidemiologia , Fibrilação Ventricular/terapia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/diagnóstico , Adulto , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Seguimentos , Adulto Jovem , Incidência , Pessoa de Meia-Idade , Parada Cardíaca/terapia , Parada Cardíaca/etiologia , Parada Cardíaca/epidemiologia , EletrocardiografiaRESUMO
Cardiovascular diseases (CVDs) are a global burden that requires attention. For the detection and diagnosis of CVDs, the 12-lead ECG is a key tool. With technological advancements, ECG devices are becoming smaller and available for home use. Most of these devices contain a limited number of leads and are aimed to detect atrial fibrillation (AF). To investigate whether a four-electrode arrangement could provide enough information to diagnose other CVDs, further research is necessary. At the University Medical Center Utrecht in a multidisciplinary team, we developed the miniECG, a four-electrode ECG handheld system for scientific research in clinical environments (TRL6). This paper describes the process followed during the development of the miniECG. From assembling a multidisciplinary team, which includes engineers, cardiologists, and clinical physicians to the contribution of team members in the design input, design, and testing for safety and functionality of the device. Finally, we detail how the development process was composed by iterative design steps based on user input and intended use evolution. The miniECG is a device compliant for scientific research with patients within Dutch Medical Centers. We believe that hospital-based development led to a streamlined process, which could be applied for the design and development of other technologies used for scientific research in clinical environments.
RESUMO
Aims: Many portable electrocardiogram (ECG) devices have been developed to monitor patients at home, but the majority of these devices are single lead and only intended for rhythm disorders. We developed the miniECG, a smartphone-sized portable device with four dry electrodes capable of recording a high-quality multi-lead ECG by placing the device on the chest. The aim of our study was to investigate the ability of the miniECG to detect occlusive myocardial infarction (OMI) in patients with chest pain. Methods and results: Patients presenting with acute chest pain at the emergency department of the University Medical Center Utrecht or Meander Medical Center, between May 2021 and February 2022, were included in the study. The clinical 12-lead ECG and the miniECG before coronary intervention were recorded. The recordings were evaluated by cardiologists and compared the outcome of the coronary angiography, if performed. A total of 369 patients were measured with the miniECG, 46 of whom had OMI. The miniECG detected OMI with a sensitivity and specificity of 65 and 92%, compared with 83 and 90% for the 12-lead ECG. Sensitivity of the miniECG was similar for different culprit vessels. Conclusion: The miniECG can record a multi-lead ECG and rule-in ST-segment deviation in patients with occluded or near-occluded coronary arteries from different culprit vessels without many false alarms. Further research is required to add automated analysis to the recordings and to show feasibility to use the miniECG by patients at home.