Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Lett ; 48(24): 6581-6584, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38099804

RESUMO

Due to the low atomic number of B, hexagonal boron nitride (hBN) has a large neutron scattering cross section and, therefore, is an ideal material for the realization of solid-state neutron detector. Here we apply the THz time-domain spectroscopy to study the effect of neutron irradiation on electronic properties of pyrolytic (PBN) and hot-pressed boron nitride (HBN). The key electronic parameters of these samples, such as the static dielectric constant ε b, the effective carrier density N*, the carrier relaxation time τ, and the electronic localization factor α, are determined optically, and their dependences upon the neutron irradiation fluence (NIF) are examined. We find that for hBN,N* and ε b decrease while τ and |α| increase with increasing NIF. These results can be used to further understand the neutron irradiation effects on the basic physical properties of hBN material. We believe that the results obtained from this work can benefit to the design and application of hBN material for neutron detectors.

2.
Med Dosim ; 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-39414422

RESUMO

The present study aimed to improve the dose distribution of radiotherapy planning for nasopharyngeal carcinoma (NPC) by comparing the effects of various minimum monitor units (MUs) per dynamic control point (MMCP) values on the quality and execution efficiency of dynamic intensity-modulated radiotherapy (IMRT) planning. Thirty-four clinically implemented dynamic IMRT plans for patients with NPC were retrospectively selected. In total, 170 plans were obtained by modifying only the MMCP values (set as 1, 3, 5, 7, and 9) in the treatment planning system's (TPS) optimization parameters. These plans were divided into 5 groups. Analyzing the effects of MMCP on the target and organ dose at risk (OAR), also the execution efficiency of the treatment plan in each group and using a quality score system, we conducted an objective quantitative study of the dose distribution and execution efficiency. The target dose evaluation indicators (target coverage (TC), homogeneity index (HI), and conformity index (CI)) of all IMRT plans showed a trend of variation with an increase in MMCP values, and the difference was statistically significant when MMCP values were 5, 7, 9, and 1 (p < 0.05). With an increase in MMCP, the dose to OAR slightly increased, but the difference was not statistically significant (p > 0.05). With an increase in MMCP, the average number of MUs per segment significantly increased (p < 0.01). The groups based on MMCP values of 1, 3, 5, 7, and 9 received quality score system of 1.188, 1.180, 1.171, 0.987, and 1.184, respectively, with the MMCP7 group achieving the lowest score, indicating that this plan had the highest overall quality. The MMCP value for dynamic IMRT planning in the Monaco TPS for patients with NPC should be set to 7 to achieve fewer segments, the best execution efficiency without significantly deteriorating the target and OAR dose.

3.
ACS Appl Mater Interfaces ; 15(28): 33744-33750, 2023 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-37431755

RESUMO

X-ray detectors based on conventional semiconductors with large atomic numbers are suffering from the poor stability under a high dose rate of ionizing irradiation. In this work, we demonstrate that a wide band gap ceramic-boron nitride with small atomic numbers could be used for sensitive X-ray detection. Boron nitride samples showed excellent resistance to ionizing radiation, which have been systematically studied with the neutron- and electron-aging experiments. Then, we fully analyzed the influence of these aging effects on the fundamental properties of boron nitride. Interestingly, we found that the boron nitride samples could maintain relatively good charge transport properties even after large dose of neutron irradiation. The fabricated X-ray detectors showed decent performance metrics, and the neutron-aged boron nitride even showed improved operational stability under continuous X-ray irradiation, suggesting the great potential for real applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA