Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Clin Chem ; 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38712647

RESUMO

BACKGROUND: Vitamin D, acknowledged since the 1930s for its role in preventing rickets, gained additional prominence in relation to fragility fracture prevention in the late 1980s. From the early 2000s, connections between vitamin D deficiency and extra-skeletal pathologies emerged, alongside increased awareness of widespread deficits. This prompted crucial debates on optimal serum concentrations, expected to conclude when the outcomes of high-dose supplementation randomized controlled trials were available. Skepticism arose with inconclusive results from these trials. CONTENT: This review begins with an exploration of vitamin D metabolism, followed by a detailed description of the measurement of vitamin D metabolites and the crucial role of standardization. Subsequent sections focus on the association of vitamin D with bone health and explore the extra-skeletal effects. The review concludes with a comprehensive discussion on the definition of vitamin D status and its implications for supplementation. SUMMARY: Despite standardization efforts, assay variations and challenges still exist, especially in specific patient groups. Vitamin D supplementation has a significant impact on bone metabolism and optimal vitamin D status improves the efficacy of antiresorptive drugs such as bisphosphonates. The extra-skeletal effects of vitamin D remain debated, but may include potential benefits in conditions such as respiratory infections and cancer mortality, particularly in deficient individuals. The definition of vitamin D sufficiency is nuanced, especially when variations in population groups and analytical methods are taken into account. Despite ongoing debates and recent mega-trials tempering enthusiasm, vitamin D remains a complex and essential element in human health. Further research is needed to clarify its role in various health outcomes and guide supplementation strategies.

2.
Am J Kidney Dis ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38796137

RESUMO

RATIONALE & OBJECTIVE: Kidneys are vital for vitamin D metabolism, and disruptions in both production and catabolism occur in chronic kidney disease. Although vitamin D activation occurs in numerous tissues, the kidneys are the most relevant source of circulating active vitamin D. This study investigates extrarenal vitamin D activation and the impact of kidney transplantation on vitamin D metabolism in patients who are anephric. STUDY DESIGN: Case series. SETTING & PARTICIPANTS: Adult patients with previous bilateral nephrectomy (anephric) not receiving active vitamin D therapy evaluated at the time of (N=38) and 1 year after (n=25) kidney transplantation. ANALYTICAL APPROACH: Chromatography with tandem mass spectrometry was used to measure vitamin D metabolites. Activity of CYP24A1 [24,25(OH)2D/25(OH)D] and CYP27B1 [1α,25(OH)2D/25(OH)D] is expressed as metabolic ratios. Differences between time points were evaluated by paired t-test or Wilcoxon matched-pairs signed-rank test. RESULTS: At time of transplantation, 1α,25(OH)2D was detectable in all patients (4-36pg/mL). There was a linear relationship between 25(OH)D and 1α,25(OH)2D levels (r=0.58, P<0.001), with 25(OH)D explaining 34% of the variation in 1α,25(OH)2D levels. There were no associations between 1α,25(OH)2D and biointact parathyroid hormone (PTH) or fibroblast growth factor 23 (FGF-23). One year after transplantation, 1α,25(OH)2D levels recovered (+205%), and CYP27B1 activity increased (+352%). Measures of vitamin D catabolism, 24,25(OH)2D and CYP24A1 activity increased 3- to 5-fold. Also, at 12 months after transplantation, 1α,25(OH)2D was positively correlated with PTH (ρ=0.603, P=0.04) but not with levels of 25(OH)D or FGF-23. LIMITATIONS: Retrospective, observational study design with a small cohort size. CONCLUSIONS: Low-normal levels of 1α,25(OH)2D was demonstrated in anephric patients, indicating production outside the kidneys. This extrarenal CYP27B1 activity may be more substrate driven than hormonally regulated. Kidney transplantation seems to restore kidney CYP27B1 and CYP24A1 activity, as evaluated by vitamin D metabolic ratios, resulting in both increased vitamin D production and catabolism. These findings may have implications for vitamin D supplementation strategies in the setting of kidney failure and transplantation. PLAIN-LANGUAGE SUMMARY: Vitamin D activation occurs in multiple tissues, but the kidneys are considered the only relevant source of circulating levels. This study investigates vitamin D activation outside the kidneys by measuring vitamin D metabolites in 38 patients without kidneys. Active vitamin D was detectable in all patients, indicating production outside of the kidneys. There was a strong relationship between active and precursor vitamin D levels, but no association with mineral metabolism hormones, indicating that vitamin D production was more substrate dependent than hormonally regulated. One year after kidney transplantation, active vitamin D levels increased 2-fold and breakdown products increased 3-fold, indicating that production and degradation of the hormone recovers after kidney transplantation. These findings are relevant for future research into vitamin D supplementation in kidney failure.

3.
Gastrointest Endosc ; 2024 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-38908453

RESUMO

BACKGROUND AND AIMS: Implementation of screening modalities have reduced the burden of colorectal cancer (CRC), but high false positive rates pose a major problem for colonoscopy capacity. We aimed to create a tailored screening algorithm that expands the fecal immunochemical test (FIT) with a blood specimen and current age to improve selection of individuals for diagnostic colonoscopy. METHODS: In this prospective multi-center study, eight blood-based biomarkers (CEA, Ferritin, hsCRP, HE4, Cyfra21-1, Hepsin, IL-8 and OPG) were investigated in 1,977 FIT positive individuals from the Danish national CRC screening program undergoing follow-up colonoscopy. Specimens were analyzed on ARCHITECT i2000®, ARCHITECT c8000® or Luminex xMAP® machines. FIT analyses and blood-based biomarker data were combined with clinical data (i.e., age and colonoscopy findings) in a cross-validated logistic regression model (algorithm) benchmarked against a model solely using the FIT result (FIT model) applying different cutoffs for FIT positivity. RESULTS: The cohort included individuals with CRC (n = 240), adenomas (n = 938) or no neoplastic lesions (n = 799). The cross-validated algorithm combining the eight biomarkers, quantitative FIT result and age performed superior to the FIT model in discriminating CRC versus non-CRC individuals (AUC 0.77 versus 0.67, p < 0.001). When discriminating individuals with either CRC or high- or medium-risk adenomas versus low-risk adenomas or clean colorectum, the AUCs were 0.68 versus 0.64 for the algorithm and FIT model, respectively. CONCLUSIONS: The algorithm presented here can improve patient allocation to colonoscopy, reducing colonoscopy burden without compromising cancer and adenomas detection rates or vice versa.

4.
Clin Chem Lab Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38874994

RESUMO

OBJECTIVES: Steroid hormone levels of patients may be monitored via dried blood spot (DBS) sampling at home. Stability of steroid hormones in DBS samples, however, needs to be established. METHODS: DBS samples from healthy volunteers were collected and stored at various temperatures. Steroid hormone concentrations in DBS were measured directly, at day 2, day 7 and day 14 following storage at 37 °C and after 7 days, 14 days, 3 months and 6 months following storage at -20 °C, 4 °C and room temperature (RT). Cortisol, cortisone, corticosterone, testosterone, androstenedione, and 17-hydroxyprogesterone (17-OHP) were assessed using LC-MS/MS. RESULTS: All steroids were stable (±15 %) up to 14 days when stored at 37 °C, except for cortisone (only stable until 2 days). All steroids were stable up to 6 months when stored at -20 °C, 4 °C and RT. However, there were some exceptions, for androstenedione at RT (only stable until 7 days), for 17-OHP when stored at -20 °C (only stable until 3 months), for cortisone at RT and 4 °C (only stable until 14 days), and cortisol at RT (only stable until 3 months). CONCLUSIONS: Overall, we demonstrated stability of steroid hormone concentrations in DBS under various conditions which may be encountered during shipping to the diagnostic laboratory and during long-term storage before analysis.

5.
Clin Chem Lab Med ; 62(6): 1080-1091, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38205643

RESUMO

OBJECTIVES: Current liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications for circulating androgen measurements are technically diverse. Previously, variable results have been reported for testosterone. Data are scarce for androstenedione and absent for dehydroepiandrosterone sulfate (DHEAS). We assessed the agreement of androstenedione, DHEAS and testosterone LC-MS/MS measurements among nine European centers and explored benefits of calibration system unification. METHODS: Androgens were measured twice by laboratory-specific procedures in 78 patient samples and in EQA materials. Results were obtained by in-house and external calibration. Intra- and inter-laboratory performances were valued. RESULTS: Intra-laboratory CVs ranged between 4.2-13.2 % for androstenedione, 1.6-10.8 % for DHEAS, and 4.3-8.7 % and 2.6-7.1 % for female and male testosterone, respectively. Bias and trueness in EQA materials were within ±20 %. Median inter-laboratory CV with in-house vs. external calibration were 12.0 vs. 9.6 % for androstenedione (p<0.001), 7.2 vs. 4.9 % for DHEAS (p<0.001), 6.4 vs. 7.6 % for female testosterone (p<0.001) and 6.8 and 7.4 % for male testosterone (p=0.111). Median bias vs. all laboratory median with in-house and external calibration were -13.3 to 20.5 % and -4.9 to 18.7 % for androstenedione, -10.9 to 4.8 % and -3.4 to 3.5 % for DHEAS, -2.7 to 6.5 % and -11.3 to 6.6 % for testosterone in females, and -7.0 to 8.5 % and -7.5 to 11.8 % for testosterone in males, respectively. CONCLUSIONS: Methods showed high intra-laboratory precision but variable bias and trueness. Inter-laboratory agreement was remarkably good. Calibration system unification improved agreement in androstenedione and DHEAS, but not in testosterone measurements. Multiple components, such as commutability of calibrators and EQA materials and internal standard choices, likely contribute to inter-laboratory variability.


Assuntos
Androstenodiona , Sulfato de Desidroepiandrosterona , Espectrometria de Massas em Tandem , Testosterona , Androstenodiona/sangue , Androstenodiona/análise , Testosterona/sangue , Testosterona/análise , Testosterona/normas , Humanos , Espectrometria de Massas em Tandem/normas , Espectrometria de Massas em Tandem/métodos , Calibragem , Masculino , Feminino , Cromatografia Líquida/normas , Cromatografia Líquida/métodos , Sulfato de Desidroepiandrosterona/sangue , Sulfato de Desidroepiandrosterona/análise , Sulfato de Desidroepiandrosterona/normas , Pessoa de Meia-Idade , Espectrometria de Massa com Cromatografia Líquida
6.
Clin Chem Lab Med ; 62(7): 1352-1361, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38205847

RESUMO

OBJECTIVES: Correct interpretation of thyroid function tests relies on correct reference intervals (RIs) for thyroid-stimulating hormone (TSH) and free thyroxine (FT4). ISO15189 mandates periodic verification of RIs, but laboratories struggle with cost-effective approaches. We investigated whether indirect methods (utilizing historical laboratory data) could replace the direct approach (utilizing healthy reference individuals) and compared results with manufacturer-provided RIs for TSH and FT4. METHODS: We collected historical data (2008-2022) from 13 Dutch laboratories to re-establish RIs by employing indirect methods, TMC (for TSH) and refineR (for FT4). Laboratories used common automated platforms (Roche, Abbott, Beckman or Siemens). Indirect RIs (IRIs) were determined per laboratory per year and clustered per manufacturer (>1.000.000 data points per manufacturer). Direct RIs (DRIs) were established in 125 healthy individuals per platform. RESULTS: TSH IRIs remained robust over the years for all manufacturers. FT4 IRIs proved robust for three manufacturers (Roche, Beckman and Siemens), but the IRI upper reference limit (URL) of Abbott showed a decrease of 2 pmol/L from 2015. Comparison of the IRIs and DRIs for TSH and FT4 showed close agreement using adequate age-stratification. Manufacturer-provided RIs, notably Abbott, Roche and Beckman exhibited inappropriate URLs (overall difference of 0.5-1.0 µIU/mL) for TSH. For FT4, the URLs provided by Roche, Abbott and Siemens were overestimated by 1.5-3.5 pmol/L. CONCLUSIONS: These results underscore the importance of RI verification as manufacturer-provided RIs are often incorrect and RIs may not be robust. Indirect methods offer cost-effective alternatives for laboratory-specific or platform-specific verification of RIs.


Assuntos
Tireotropina , Tiroxina , Humanos , Tiroxina/sangue , Tiroxina/análise , Tireotropina/sangue , Tireotropina/análise , Tireotropina/normas , Valores de Referência , Testes de Função Tireóidea/normas , Testes de Função Tireóidea/métodos , Adulto , Feminino , Masculino , Pessoa de Meia-Idade , Rotulagem de Produtos/normas
7.
Clin Chem ; 69(12): 1361-1373, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37794651

RESUMO

BACKGROUND: Androgens are synthesized from cholesterol through sequential conversions by enzymes in the adrenal glands and gonads. Serum levels of androgens change during the different phases of life and regulate important developmental and maturational processes. Androgen excess or deficiency can therefore present at various ages in various ways. CONTENT: The diagnostic approach for atypical genitalia, premature pubarche, delayed pubertal onset or progression, and hirsutism or virilization, including measurement of androgens (testosterone, androstenedione, 17-OHprogesterone, dehydroepiandrosterone, and dihydrotestosterone) is discussed in the current review. Androgens can be measured in serum, saliva, urine, or dried blood spots. Techniques to measure androgens, including immunoassays and LC-MS, have their own advantages and pitfalls. In addition, pre- and postanalytical issues are important when measuring androgens. SUMMARY: During clinical interpretation of androgen measurements, it is important to take preanalytical circumstances, such as time of blood withdrawal, into account. As immunoassays have major drawbacks, especially in samples from women and neonates, concentrations measured using these assays should be interpreted with care. Reference intervals can only be used in relation to the measurement technique and the standardization of the assay. In the near future, new androgens will probably be added to the current repertoire to further improve the diagnosis and follow-up of androgen excess or deficiency.


Assuntos
Androgênios , Testosterona , Recém-Nascido , Feminino , Humanos , Androstenodiona , Virilismo , Hirsutismo/diagnóstico , Desidroepiandrosterona
8.
Calcif Tissue Int ; 112(2): 258-270, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35665817

RESUMO

Two decades after the discovery of the hormone FGF23, we know more about phosphate homeostasis as it turned out that FGF23 is the central hormone that regulates this. Hereditary hypophosphatemic rickets and tumor-induced osteomalacia could by then be explained, by autonomous FGF23 production, and the nephrology field was excited by this new marker as it turned out to be independently associated with mortality in people treated by hemodialysis. This led to the development of several immunoassays to be able to measure FGF23 in blood. In the past years we learned that FGF23 is a rather stable peptide, the precision of the assays is acceptable but assays are not standardized and therefore not comparable. This means that reference values and cutoff values need to be assay specific. For several assays reference values have been established and gender and age did not seem of high importance. The phosphate content of the diet, which can be culturally dependent, however, should be taken into account when interpreting results, but to what extent is not totally clear. Currently, clinical application of the immunoassays is established in the diagnosis of hereditary hypophosphatemic rickets and diagnosis and follow-up of tumor-induced osteomalacia. Definite conclusions on the usefulness of the FGF23 measurement in people with CKD either as a marker for risk prediction or a as target for treatment remains to be determined. The latter applications would require dedicated prospective clinical trials, which may take years, before providing answers. To improve the standardization of the FGF23 assays and to shed light on the biological functions that fragments might have we might aim for an LC-MS/MS-based method to quantify both intact and fragmented FGF23. In this literature review we will summarize the current knowledge on the physiological role of FGF23, its quantification, and the clinical usefulness of its determination.


Assuntos
Raquitismo Hipofosfatêmico Familiar , Osteomalacia , Humanos , Cromatografia Líquida , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos/metabolismo , Hormônios/uso terapêutico , Fosfatos/metabolismo , Estudos Prospectivos , Espectrometria de Massas em Tandem
9.
Reprod Biomed Online ; 46(6): 973-981, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37005152

RESUMO

RESEARCH QUESTION: What is the risk of hypogonadism in men with obstructive azoospermia, non-obstructive azoospermia (NOA) or Klinefelter syndrome after testicular sperm extraction (TESE)? DESIGN: This prospective longitudinal cohort study was carried out between 2007 and 2015. RESULTS: Around 36% of men with Klinefelter syndrome, 4% of men with obstructive azoospermia and 3% of men with NOA needed testosterone replacement therapy (TRT). Klinefelter syndrome was strongly associated with TRT while no association was found between obstructive azoospermia or NOA and TRT. Irrespective of the pre-operative diagnosis, a higher testosterone concentration before TESE was associated with a lower chance of needing TRT. CONCLUSIONS: Men with obstructive azoospermia or NOA have a similar moderate risk of clinical hypogonadism after TESE, while this risk is much larger for men with Klinefelter syndrome. The risk of clinical hypogonadism is lower when testosterone concentrations are high before TESE.


Assuntos
Azoospermia , Hipogonadismo , Síndrome de Klinefelter , Masculino , Humanos , Azoospermia/terapia , Estudos Prospectivos , Síndrome de Klinefelter/complicações , Estudos Longitudinais , Recuperação Espermática , Estudos Retrospectivos , Sêmen , Testículo/cirurgia , Espermatozoides , Hipogonadismo/complicações , Testosterona
10.
Pediatr Res ; 94(5): 1804-1809, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37355738

RESUMO

BACKGROUND: Systemic inflammation plays a key role in the development of bronchopulmonary dysplasia (BPD). Cortisol is known to dampen inflammation. However, adrenal function following preterm birth is characterized by insufficient cortisol levels for the degree of inflammation, and a relative abundancy of cortisol precursors. We investigated whether this pattern could contribute to the development of BPD in preterm infants born <30 weeks of gestation. METHODS: Cortisol, cortisone, 17-OH progesterone (17-OHP) and 11-deoxycortisol were measured in serum obtained at postnatal days 1, 3, 7, 14 and 28, using liquid-chromatography-tandem-mass-spectrometry. The presence of BPD was ascertained at 36 weeks postmenstrual age. RESULTS: Sixty-five infants were included for analysis, of whom 32 (49%) developed BPD. Preterm infants developing BPD, as compared to those without BPD, had higher levels of 17-OHP, 11-deoxycortisol and cortisone relative to cortisol in their first week of life, but not at birth or beyond day 7. CONCLUSION: Preterm infants developing BPD had higher levels of cortisol precursors and cortisone relative to cortisol in their first week of life than infants without BPD. These findings suggest that BPD is preceded by an activated hypothalamus-pituitary-adrenal axis that could not meet the high cortisol demands, which may predispose to inflammation and BPD. IMPACT: Relative adrenal insufficiency is common in the first weeks after preterm birth, resulting in insufficient cortisol production for the degree of inflammation and a relative abundance of cortisol precursors; Whether this pattern contributes to the development of bronchopulmonary dysplasia (BPD) is not fully elucidated, since most studies focused on cortisol levels; Preterm infants developing BPD had higher levels of cortisol precursors and cortisone relative to cortisol in the first week of life, suggestive of a hypothalamus-pituitary-adrenal-axis activation during BPD development which cannot meet the high cortisol demands in tissues; This glucocorticoid pattern is likely to dispose to inflammation and BPD.


Assuntos
Displasia Broncopulmonar , Cortisona , Nascimento Prematuro , Lactente , Feminino , Recém-Nascido , Humanos , Glucocorticoides , Recém-Nascido Prematuro , Hidrocortisona , Cortodoxona , Inflamação
11.
J Inherit Metab Dis ; 46(1): 116-128, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36256460

RESUMO

Males with X-linked adrenoleukodystrophy (ALD) are at high risk for developing adrenal insufficiency and/or progressive leukodystrophy (cerebral ALD) at an early age. Pathogenic variants in ABCD1 result in elevated levels of very long-chain fatty acids (VLCFA), including C26:0-lysophosphatidylcholine (C26:0-LPC). Newborn screening for ALD enables prospective monitoring and timely therapeutic intervention, thereby preventing irreversible damage and saving lives. The Dutch Health Council recommended to screen only male newborns for ALD without identifying untreatable conditions associated with elevated C26:0-LPC, like Zellweger spectrum disorders and single peroxisomal enzyme defects. Here, we present the results of the SCAN (Screening for ALD in the Netherlands) study which is the first sex-specific newborn screening program worldwide. Males with ALD are identified based on elevated C26:0-LPC levels, the presence of one X-chromosome and a variant in ABCD1, in heel prick dried bloodspots. Screening of 71 208 newborns resulted in the identification of four boys with ALD who, following referral to the pediatric neurologist and confirmation of the diagnosis, enrolled in a long-term follow-up program. The results of this pilot show the feasibility of employing a boys-only screening algorithm that identifies males with ALD without identifying untreatable conditions. This approach will be of interest to countries that are considering ALD newborn screening but are reluctant to identify girls with ALD because for girls there is no direct health benefit. We also analyzed whether gestational age, sex, birth weight and age at heel prick blood sampling affect C26:0-LPC concentrations and demonstrate that these covariates have a minimal effect.


Assuntos
Insuficiência Adrenal , Adrenoleucodistrofia , Criança , Feminino , Humanos , Masculino , Recém-Nascido , Adrenoleucodistrofia/diagnóstico , Adrenoleucodistrofia/genética , Triagem Neonatal/métodos , Estudos Prospectivos , Lisofosfatidilcolinas , Ácidos Graxos
12.
Clin Chem Lab Med ; 61(8): 1436-1445, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-36877870

RESUMO

OBJECTIVES: Hormone measurements using automated immunoassays (IAs) can be affected by the sample matrix. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is less affected by these matrix effects. In clinical laboratories, testosterone, cortisol and, free thyroxine (FT4) are often measured using IAs. Renal failure alters serum composition in blood samples from people undergoing hemodialysis (HDp) and have, therefore, a complex serum constitution compared to healthy controls (HC). The goal of this study was to investigate the accuracy of testosterone, cortisol, and FT4 measurements in samples of HDp and to get more insight in the interfering factors. METHODS: Thirty serum samples from HDp and HC were collected to measure testosterone, cortisol, and FT4 using a well standardized isotope dilution (ID)-LC-MS/MS method and 5 commercially available automated IAs (Alinity, Atellica, Cobas, Lumipulse, UniCel DXI). Method comparisons between LC-MS/MS and IAs were performed using both HDp and HC samples. RESULTS: Average bias from the LC-MS/MS was for testosterone, cortisol, and FT4 immunoassays respectively up to 92, 7-47 and 16-27% more in HDp than in HC samples and was IA dependent. FT4 IA results were falsely decreased in HDp samples, whereas cortisol and testosterone concentrations in females were predominantly falsely increased. Correlation coefficients between LC-MS/MS and IA results were lower in HDp compared to HC samples. CONCLUSIONS: Several IAs for testosterone (in women), cortisol, and FT4 are less reliable in the altered serum matrix of samples of HDp than in HC. Medical and laboratory specialists should be aware of these pitfalls in this specific population.


Assuntos
Hidrocortisona , Testosterona , Humanos , Feminino , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Imunoensaio/métodos , Diálise Renal
13.
Clin Chem Lab Med ; 61(9): 1605-1611, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36994743

RESUMO

OBJECTIVES: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. METHODS: This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. RESULTS: It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. CONCLUSIONS: Our candidate cRMP measures FT4 accurately and performs well in serum matrix.


Assuntos
Espectrometria de Massas em Tandem , Tiroxina , Humanos , Cromatografia Líquida/métodos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Diálise Renal , Isótopos , Padrões de Referência
14.
Clin Chem Lab Med ; 61(9): 1561-1566, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36995129

RESUMO

OBJECTIVES: The exploration of the metabolites in the degradation pathways of vitamin D (VTD) has gained importance in recent years and simultaneous quantitation of twenty-five-hydroxy vitamin D (25(OH)D) mass concentration together with 24,25-dihydroxyvitamin D (24,25(OH)2D) has been proposed as a newer approach to define VTD deficiency. Yet, no data are available on 24,25(OH)2D biological variation (BV). In this study, we evaluated 24,25(OH)2D's BV on the European Biological Variation Study (EuBIVAS) cohort samples to determine if analytical performance specifications (APS) for 24,25(OH)2D could be generated. METHODS: Six European laboratories recruited 91 healthy participants. 25(OH)D and 24,25(OH)2D concentrations in K3-EDTA plasma were examined weekly for up to 10 weeks in duplicate with a validated LC-MS/MS method. The Vitamin D Metabolite Ratio (24,25(OH)2D divided by 25(OH)D × 100) was also calculated at each time point. RESULTS: Linear regression of the mean 24,25(OH)2D concentrations at each blood collection showed participants were not in steady state. Variations of 24,25(OH)2D over time were significantly positively associated with the slopes of 25(OH)D concentrations over time and the concentration of 25(OH)D of the participant at inclusion, and negatively associated with body mass index (BMI), but not with age, gender, or location of the participant. The variation of the 24,25(OH)2D concentration in participants over a 10 weeks period was 34.6%. Methods that would detect a significant change linked to the natural production of 24,25(OH)2D over this period at p<0.05 would need a relative measurement uncertainty (u%)<14.9% while at p<0.01, relative measurement uncertainty should be <10.5%. CONCLUSIONS: We have defined for the first time APS for 24,25(OH)2D examinations. According to the growing interest in this metabolite, several laboratories and manufacturers might aim to develop specific methods for its determination. The results presented in this paper are thus necessary prerequisites for the validation of such methods.


Assuntos
Espectrometria de Massas em Tandem , Deficiência de Vitamina D , Humanos , Cromatografia Líquida/métodos , Incerteza , Espectrometria de Massas em Tandem/métodos , Vitamina D , Deficiência de Vitamina D/diagnóstico , Vitaminas
15.
Clin Chem Lab Med ; 61(1): 67-77, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36288389

RESUMO

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) panels that include glucocorticoid-related steroids are increasingly used to characterize and diagnose adrenal cortical diseases. Limited information is currently available about reproducibility of these measurements among laboratories. The aim of the study was to compare LC-MS/MS measurements of corticosterone, 11-deoxycortisol and cortisone at eight European centers and assess the performance after unification of calibration. METHODS: Seventy-eight patient samples and commercial calibrators were measured twice by laboratory-specific procedures. Results were obtained according to in-house and external calibration. We evaluated intra-laboratory and inter-laboratory imprecision, regression and agreement against performance specifications derived from 11-deoxycortisol biological variation. RESULTS: Intra-laboratory CVs ranged between 3.3 and 7.7%, 3.3 and 11.8% and 2.7 and 12.8% for corticosterone, 11-deoxycortisol and cortisone, with 1, 4 and 3 laboratories often exceeding the maximum allowable imprecision (MAI), respectively. Median inter-laboratory CVs were 10.0, 10.7 and 6.2%, with 38.5, 50.7 and 2.6% cases exceeding the MAI for corticosterone, 11-deoxycortisol and cortisone, respectively. Median laboratory bias vs. all laboratory-medians ranged from -5.6 to 12.3% for corticosterone, -14.6 to 12.4% for 11-deoxycortisol and -4.0 to 6.5% for cortisone, with few cases exceeding the total allowable error. Modest deviations were found in regression equations among most laboratories. External calibration did not improve 11-deoxycortisol and worsened corticosterone and cortisone inter-laboratory comparability. CONCLUSIONS: Method imprecision was variable. Inter-laboratory performance was reasonably good. However, cases with imprecision and total error above the acceptable limits were apparent for corticosterone and 11-deoxycortisol. Variability did not depend on calibration but apparently on imprecision, accuracy and specificity of individual methods. Tools for improving selectivity and accuracy are required to improve harmonization.


Assuntos
Cortisona , Humanos , Cromatografia Líquida/métodos , Cortodoxona , Corticosterona , Espectrometria de Massas em Tandem/métodos , Reprodutibilidade dos Testes
16.
Clin Chem Lab Med ; 60(1): 60-65, 2022 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-34643074

RESUMO

OBJECTIVES: Corticotropin is notorious for its instability. Whereas several studies have investigated its short-term stability in plasma following venous blood sampling, studies on long-term stability are lacking. Here we investigated the long-term storage stability of corticotropin in ethylenediaminetetraacetic acid containing plasma. METHODS: Specimens from healthy volunteers (neat, spiked) were stored in polypropylene microcentrifuge tubes with socket screw-caps at -20 °C and -70 °C for up to one and a half years. Corticotropin in plasma was measured using an Abbott research only immunoassay. Separately, specimens from patients were collected during diagnostic routine testing and stored in polystyrene tubes with push-caps at -20 °C for up to 6 years. In these samples corticotropin hormone was measured using the Diasorin corticotropin immunoassay. RESULTS: Storage of specimens at -20 °C or -70 °C for up to one and a half years showed minimal changes (<11%) in corticotropin levels, while storage of patient samples at -20 °C for up to 6 years showed a significant (54%) reduction in corticotropin levels. CONCLUSIONS: Corticotropin levels are stable in plasma when stored at -20 °C for one and a half years using the Abbott research only assay, but with longer storage time a significant reduction in corticotropin levels can be expected. Once specimens are stored for future corticotropin measurements, one should consider storage time, storage temperature and assay differences.


Assuntos
Hormônio Adrenocorticotrópico , Manejo de Espécimes , Hormônio Adrenocorticotrópico/química , Ácido Edético , Humanos , Plasma , Estabilidade Proteica , Temperatura
17.
Clin Chem Lab Med ; 60(5): 726-739, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35172417

RESUMO

OBJECTIVES: Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is recommended for measuring circulating steroids. However, assays display technical heterogeneity. So far, reproducibility of corticosteroid LC-MS/MS measurements has received scant attention. The aim of the study was to compare LC-MS/MS measurements of cortisol, 17OH-progesterone and aldosterone from nine European centers and assess performance according to external quality assessment (EQA) materials and calibration. METHODS: Seventy-eight patient samples, EQA materials and two commercial calibration sets were measured twice by laboratory-specific procedures. Results were obtained by in-house (CAL1) and external calibrations (CAL2 and CAL3). We evaluated intra and inter-laboratory imprecision, correlation and agreement in patient samples, and trueness, bias and commutability in EQA materials. RESULTS: Using CAL1, intra-laboratory CVs ranged between 2.8-7.4%, 4.4-18.0% and 5.2-22.2%, for cortisol, 17OH-progesterone and aldosterone, respectively. Trueness and bias in EQA materials were mostly acceptable, however, inappropriate commutability and target value assignment were highlighted in some cases. CAL2 showed suboptimal accuracy. Median inter-laboratory CVs for cortisol, 17OH-progesterone and aldosterone were 4.9, 11.8 and 13.8% with CAL1 and 3.6, 10.3 and 8.6% with CAL3 (all p<0.001), respectively. Using CAL1, median bias vs. all laboratory-medians ranged from -6.6 to 6.9%, -17.2 to 7.8% and -12.0 to 16.8% for cortisol, 17OH-progesterone and aldosterone, respectively. Regression lines significantly deviated from the best fit for most laboratories. Using CAL3 improved cortisol and 17OH-progesterone between-method bias and correlation. CONCLUSIONS: Intra-laboratory imprecision and performance with EQA materials were variable. Inter-laboratory performance was mostly within specifications. Although residual variability persists, adopting common traceable calibrators and RMP-determined EQA materials is beneficial for standardization of LC-MS/MS steroid measurements.


Assuntos
Hidrocortisona , Progesterona , Aldosterona , Calibragem , Cromatografia Líquida/métodos , Humanos , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos
18.
Kidney Int ; 99(5): 1173-1178, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33422551

RESUMO

Parathyroid hormone (PTH) is a key regulator of bone turnover but can be oxidized in vivo, which impairs biological activity. Variable PTH oxidation may account for the rather poor correlation of PTH with indices of bone turnover in chronic kidney disease. Here, we tested whether non-oxidized PTH is superior to total PTH as a marker of bone turnover in 31 patients with kidney failure included from an ongoing prospective observational bone biopsy study and selected to cover the whole spectrum of bone turnover. Receiver Operating Characteristic (ROC) curves, Spearman correlation and regression analysis of non-oxidized PTH, total PTH and bone turnover markers (bone-specific alkaline phosphatase, procollagen N-terminal pro-peptide and tartrate-resistant acid phosphatase 5b) were used to assess the capability of non-oxidized PTH vs. total PTH to discriminate low from non-low and high from non-high bone turnover, as assessed quantitatively by bone histomorphometry. Serum levels of non-oxidized PTH and total PTH were strongly and significantly correlated. Histomorphometric parameters of bone turnover and the circulating bone turnover markers showed similar correlation coefficients with non-oxidized PTH and total PTH. The area under the ROC (AUROC) values for discriminating between low/non-low turnover for non-oxidized PTH and total PTH were significant and comparable (0.82 and 0.79, respectively). For high/non-high turnover the AUROCs were also significant and of the same magnitude (0.76 and 0.80, respectively). Thus, measuring non-oxidized PTH using the currently available method provides no added value compared to total PTH as an indicator of bone turnover in patients with kidney failure.


Assuntos
Distúrbio Mineral e Ósseo na Doença Renal Crônica , Falência Renal Crônica , Insuficiência Renal Crônica , Fosfatase Alcalina , Biomarcadores , Remodelação Óssea , Osso e Ossos , Distúrbio Mineral e Ósseo na Doença Renal Crônica/diagnóstico , Humanos , Falência Renal Crônica/diagnóstico , Hormônio Paratireóideo , Diálise Renal , Insuficiência Renal Crônica/diagnóstico
19.
Eur J Neurosci ; 54(4): 5261-5271, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34184338

RESUMO

Fibroblast growth factor 23 (FGF23) is an endocrine growth factor and known to play a pivotal role in phosphate homeostasis. Interestingly, several studies point towards a function of FGF23 in the hypothalamus. FGF23 classically activates the FGF receptor 1 in the presence of the co-receptor αKlotho, of both gene expression in the brain was previously established. However, studies on gene and protein expression of FGF23 in the brain are scarce and have been inconsistent. Therefore, our aim was to localise FGF23 gene and protein expression in the rat brain with focus on the hypothalamus. Also, we investigated the protein expression of αKlotho. Adult rat brains were used to localise and visualise FGF23 and αKlotho protein in the hypothalamus by immunofluorescence labelling. Furthermore, western blots were used for assessing hypothalamic FGF23 protein expression. FGF23 gene expression was investigated by qPCR in punches of the arcuate nucleus, lateral hypothalamus, paraventricular nucleus, choroid plexus, ventrolateral thalamic nucleus and the ventromedial hypothalamus. Immunoreactivity for FGF23 and αKlotho protein was found in the hypothalamus, third ventricle lining and the choroid plexus. Western blot analysis of the hypothalamus confirmed the presence of FGF23. Gene expression of FGF23 was not detected, suggesting that the observed FGF23 protein is not brain-derived. Several FGF receptors are known to be present in the brain. Therefore, we conclude that the machinery for FGF23 signal transduction is present in several brain areas, indeed suggesting a role for FGF23 in the brain.


Assuntos
Fatores de Crescimento de Fibroblastos , Glucuronidase , Animais , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos/genética , Fatores de Crescimento de Fibroblastos/metabolismo , Glucuronidase/metabolismo , Hipotálamo/metabolismo , Ratos , Receptores de Fatores de Crescimento de Fibroblastos/metabolismo
20.
J Pediatr Gastroenterol Nutr ; 73(5): e115-e119, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34183615

RESUMO

BACKGROUND OBJECTIVES: Human milk (HM) is better tolerated than formula in preterm infants. Insulin, which is naturally present in HM but not in formula, has been suggested as a key factor for feeding tolerance, as it appears to stimulate intestinal maturation. Its precise concentrations during the early postnatal period, however, remains unknown. The objective of this study was to assess the natural timecourse of the HM insulin concentration during the first ten days postpartum. The effect of preterm delivery, maternal obesity, and diurnal rhythm were also assessed. METHOD: HM was collected from 31 non-diabetic mothers (21 preterm [gestational age (GA) < 37 weeks]; 10 at-term [GA ≥ 37 weeks]) on ≥ 4 time-points per day during the first five days, and once on the tenth day postpartum. RESULTS: The HM insulin concentration declined rapidly within the first three days postpartum (day 1: 516 [312-1058] pmol/L; day 3: 157 [87-299] pmol/L), after which the concentration remained relatively stable. The insulin concentrations were higher in HM from obese mothers than from non-obese mothers (P < 0.001). Preterm delivery did not significantly affect HM insulin concentrations when adjusted for maternal pre-pregnancy body mass index category (P = 0.270). Diurnal rhythm was characterized by an insulin concentration decline throughout the night (P = 0.001), followed by an increase in the morning (P = 0.001). CONCLUSION: The HM insulin concentration declines rapidly in the first three days postpartum, follows a diurnal rhythm, and is higher in obese mothers compared to non-obese mothers. HM insulin concentrations are not affected by preterm delivery.


Assuntos
Insulina , Leite Humano , Aleitamento Materno , Feminino , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Período Pós-Parto , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA