Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Doc Ophthalmol ; 145(2): 133-145, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35788850

RESUMO

PURPOSE: To investigate the applicability of liquid crystal displays (LCD) as suitable replacement for cathode ray tube monitors (CRT) as stimulator for the sweep VEP for estimating visual acuity. METHODS: In a first experiment, sweep VEPs were recorded in 13 healthy volunteers with best-corrected visual acuity with an LCD and a CRT monitor, respectively. Time-to-peak after stimulus and peak-to-trough amplitudes as well as the visual acuity, estimated using a second-order polynomial and the modified Ricker model, were compared between both monitor types. In a second experiment, sweep VEPs were recorded in six healthy volunteers with two levels of stimulus contrast using artificially reduced visual acuities as well as best-corrected with the same monitors as in the first experiment and additionally, a modern LCD gaming monitor with a response time of 1 ms. Time-to-peak after stimulus and peak-to-trough amplitudes were compared between the different combinations of monitors and contrasts. Finally, visual acuities estimated using the modified Ricker model were compared to subjective visual acuities determined using the Freiburg Visual Acuity and Contrast Test (FrACT). RESULTS: In the first experiment, the time-to-peak after stimulus presentation was statistically significantly delayed for LCD displays (mean difference [confidence interval]: 60.0 [54.0, 65.9] ms; t(516) = 19.7096, p < 0.0001). Likewise, peak-to-trough amplitudes were statistically significantly smaller for the LCD stimulator, however, not clinically relevant (mean difference [confidence interval]: - 0.89 [- 1.59, - 0.20] µV; t(516) = - 2.5351, p = 0.0115). No statistically significant effect of the monitor type on the estimated visual acuity was found for neither method, second-order polynomial, nor the modified Ricker model. In the second experiment, statistically significant delays of the time-to-peak after stimulus onset were found for all combinations of monitor and contrast compared to the CRT monitor. A statistically significant, but not clinically relevant, difference of the peak-to-trough amplitudes was only found between the CRT monitor and the LCD gaming monitor (mean difference [confidence interval]: 2.6 [1.2, 4.0] µV; t(814) = 4.66, p < 0.0001). Visual acuities estimated from LCD stimulation significantly underestimated the subjective visual acuity up to 0.2 logMAR using the conversion formula of the first experiment. No statistically significant difference was found when using conversion formulas adjusted for each combination of monitor and contrast. CONCLUSIONS: Based on the results of this study, LCD monitors may substitute CRT monitors for presenting the stimuli for the sweep VEP to objectively estimate visual acuity. Nevertheless, it is advisable to perform a calibration and to collect normative data of healthy volunteers using best-corrected and artificially reduced visual acuity for establishing a conversion formula between sweep VEP outcome and the subjective visual acuity before replacing a CRT with an LCD stimulator.


Assuntos
Potenciais Evocados Visuais , Cristais Líquidos , Eletrorretinografia , Humanos , Testes Visuais/métodos , Acuidade Visual
2.
Doc Ophthalmol ; 138(2): 97-116, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30694438

RESUMO

PURPOSE: The aim of this study was to develop a simple and reliable method for the objective assessment of visual acuity by optimizing the stimulus used in commercially available systems and by improving the methods of evaluation using a nonlinear function, the modified Ricker model. METHODS: Subjective visual acuity in the normal subjects was measured with Snellen targets, best-corrected, and in some cases also uncorrected and with plus lenses (+ 1 D, + 2 D, + 3 D). In patients, subjective visual acuity was measured best-corrected using the Freiburg Visual Acuity Test. Sweep VEP recordings to 11 spatial frequencies, with check sizes in logarithmically equidistant steps (0.6, 0.9, 1.4, 2.1, 3.3, 4.9, 7.3, 10.4, 18.2, 24.4, and 36.5 cpd), were obtained from 56 healthy subjects aged between 17 and 69 years (mean 42.5 ± 15.3 SD years) and 20 patients with diseases of the lens (n = 6), retina (n = 8) or optic nerve (n = 6). The results were fit by a multiple linear regression (2nd-order polynomial) or a nonlinear regression (modified Ricker model) and parameters compared (limiting spatial frequency (sflimiting) and the spatial frequency of the vertex (sfvertex) of the parabola for the 2nd-order polynomial fitting, and the maximal spatial frequency (sfmax), and the spatial frequency where the amplitude is 2 dB higher than the level of noise (sfthreshold) for the modified Ricker model. RESULTS: Recording with 11 spatial frequencies allows a more accurate determination of acuities above 1.0 logMAR. Tuning curves fitted to the results show that compared to the normal 2nd-order polynomial analysis, the modified Ricker model is able to describe closely the amplitudes of the sweep VEP in relation to the spatial frequencies of the presented checkerboards. In patients with a visual acuity better than about 0.5 (decimal), the predicted acuities based on the different parameters show a good match of the predicted visual acuities based on the models established in healthy volunteers to the subjective visual acuities. However, for lower visual acuities, both models tend to overestimate the visual acuity (up to ~ 0.4 logMAR), especially in patients suffering from AMD. CONCLUSIONS: Both models, the 2nd-order polynomial and the modified Ricker model performed equally well in the prediction of the visual acuity based on the amplitudes recorded using the sweep VEP. However, the modified Ricker model does not require the exclusion of data points from the fit, as necessary when fitting the 2nd-order polynomial model making it more reliable and robust against outliers, and, in addition, provides a measure for the noise of the recorded results.


Assuntos
Potenciais Evocados Visuais/fisiologia , Doenças do Cristalino/fisiopatologia , Doenças do Nervo Óptico/fisiopatologia , Doenças Retinianas/fisiopatologia , Acuidade Visual/fisiologia , Adolescente , Adulto , Idoso , Eletrorretinografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Testes Visuais/métodos , Adulto Jovem
3.
Front Bioeng Biotechnol ; 9: 557761, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33816445

RESUMO

Recent studies suggest that transitory blood flow restriction (BFR) may improve the outcomes of training from anatomical (hypertrophy) and neural control perspectives. Whilst the chronic consequences of BFR on local metabolism and tissue adaptation have been extensively investigated, its acute effects on motor control are not yet fully understood. In this study, we compared the neuromechanical effects of continuous BFR against non-restricted circulation (atmospheric pressure-AP), during isometric elbow flexions. BFR was achieved applying external pressure either between systolic and diastolic (lower pressure-LP) or 1.3 times the systolic pressure (higher pressure-HP). Three levels of torque (15, 30, and 50% of the maximal voluntary contraction-MVC) were combined with the three levels of pressure for a total of 9 (randomized) test cases. Each condition was repeated 3 times. The protocol was administered to 12 healthy young adults. Neuromechanical measurements (torque and high-density electromyography-HDEMG) and reported discomfort were used to investigate the response of the central nervous system to BFR. The investigated variables were: root mean square (RMS), and area under the curve in the frequency domain-for the torque, and average RMS, median frequency and average muscle fibres conduction velocity-for the EMG. The discomfort caused by BFR was exacerbated by the level of torque and accumulated over time. The torque RMS value did not change across conditions and repetitions. Its spectral content, however, revealed a decrease in power at the tremor band (alpha-band, 5-15 Hz) which was enhanced by the level of pressure and the repetition number. The EMG amplitude showed no differences whilst the median frequency and the conduction velocity decreased over time and across trials, but only for the highest levels of torque and pressure. Taken together, our results show strong yet transitory effects of BFR that are compatible with a motor neuron pool inhibition caused by increased activity of type III and IV afferences, and a decreased activity of spindle afferents. We speculate that a compensation of the central drive may be necessary to maintain the mechanical output unchanged, despite disturbances in the afferent volley to the motor neuron pool.

4.
IEEE J Biomed Health Inform ; 22(2): 607-610, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28103197

RESUMO

Measurement of the dark-adaptation threshold plays a key role in the diagnosis and estimation of disease progression of many retinal disorders. Determining the threshold is, however, difficult to perform in young children. We present here a prototype for a dark adaptometer, the Tuebingen Scotopic Threshold Test aimed to ease measurement of photoreceptor thresholds in young subjects. The device consists of two 7 cm ×10 cm fields with either blue or yellow LEDs, for testing rod or cone sensitivity, respectively. Presentation of homogenous field patterns or a flickering stimulus is also possible. The luminance threshold is measured by the method of ascending limits and the stimulus luminance, data recording and analysis are computer controlled. Preliminary results for six adults and two older children were ascertained and the influence of pupil dilation, binocular presentation, and a flickering stimulus examined. The method provides credible and consistent evaluations of the absolute threshold.


Assuntos
Adaptação à Escuridão/fisiologia , Técnicas de Diagnóstico Oftalmológico , Retina/fisiologia , Adolescente , Adulto , Idoso , Criança , Humanos , Pessoa de Meia-Idade , Miose/diagnóstico , Miose/fisiopatologia , Midríase/diagnóstico , Midríase/fisiopatologia , Psicofísica , Retina/fisiopatologia , Percepção Visual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA