Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 279
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 34(2): 1016-1025, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37597032

RESUMO

OBJECTIVES: Myocardial extracellular volume (ECV) on computed tomography (CT), an alternative to cardiac magnetic resonance (CMR), has significant practical clinical advantages. However, the consistency between ECVs quantified via CT and CMR in cardiac amyloidosis (CA) has not been investigated sufficiently. Therefore, the current study investigated the application of CT-ECV in CA with CMR-ECV as the reference standard. METHODS: We retrospectively evaluated 31 patients with CA who underwent cardiac CT and CMR. Pearson correlation analysis was performed to investigate correlations between CT-ECV and CMR-ECV at each segment. Further, correlations between ECV and clinical parameters were assessed. RESULTS: There were no significant differences in the mean global ECVs between CT scan and CMR (51.3% ± 10.2% vs 50.0% ± 10.5%). CT-ECV was correlated with CMR-ECV at the septal (r = 0.88), lateral (r = 0.80), inferior (r = 0.79), anterior (r = 0.77) segments, and global (r = 0.87). In both CT and CMR, the ECV had a weak to strong correlation with high-sensitivity cardiac troponin T level, a moderate correlation with global longitudinal strain, and an inverse correlation with left ventricular ejection fraction. Further, the septal ECV and global ECV had a slightly higher correlation with the clinical parameters. CONCLUSIONS: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA. Moreover, a significant correlation between CT-ECV and clinical parameters was observed. Thus, CT-ECV can be an imaging biomarker and alternative to CMR-ECV. CLINICAL RELEVANCE STATEMENT: Cardiac CT can quantify myocardial ECV and yield results comparable to CMR in patients with CA, and CT-ECV can be used clinically as an imaging biomarker and alternative to CMR-ECV. KEY POINTS: • A significant correlation was found between CT myocardial extracellular volume and cardiac MR myocardial extracellular volume in patients with cardiac amyloidosis. • In CT and cardiac MR, the myocardial extracellular volume correlated well with high-sensitivity cardiac troponin T level, global longitudinal strain, and left ventricular ejection fraction. • CT myocardial extracellular volume can be an imaging biomarker and alternative to cardiac MR myocardial extracellular volume.


Assuntos
Amiloidose , Troponina T , Humanos , Volume Sistólico , Estudos Retrospectivos , Imagem Cinética por Ressonância Magnética/métodos , Função Ventricular Esquerda , Miocárdio/patologia , Imageamento por Ressonância Magnética , Amiloidose/diagnóstico por imagem , Biomarcadores , Valor Preditivo dos Testes
2.
Eur Radiol ; 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38753193

RESUMO

OBJECTIVES: To investigate the feasibility of low-radiation dose and low iodinated contrast medium (ICM) dose protocol combining low-tube voltage and deep-learning reconstruction (DLR) algorithm in thin-slice abdominal CT. METHODS: This prospective study included 148 patients who underwent contrast-enhanced abdominal CT with either 120-kVp (600 mgL/kg, n = 74) or 80-kVp protocol (360 mgL/kg, n = 74). The 120-kVp images were reconstructed using hybrid iterative reconstruction (HIR) (120-kVp-HIR), while 80-kVp images were reconstructed using HIR (80-kVp-HIR) and DLR (80-kVp-DLR) with 0.5 mm thickness. Size-specific dose estimate (SSDE) and iodine dose were compared between protocols. Image noise, CT attenuation, and contrast-to-noise ratio (CNR) were quantified. Noise power spectrum (NPS) and edge rise slope (ERS) were used to evaluate noise texture and edge sharpness, respectively. The subjective image quality was rated on a 4-point scale. RESULTS: SSDE and iodine doses of 80-kVp were 40.4% (8.1 ± 0.9 vs. 13.6 ± 2.7 mGy) and 36.3% (21.2 ± 3.9 vs. 33.3 ± 4.3 gL) lower, respectively, than those of 120-kVp (both, p < 0.001). CT attenuation of vessels and solid organs was higher in 80-kVp than in 120-kVp images (all, p < 0.001). Image noise of 80-kVp-HIR and 80-kVp-DLR was higher and lower, respectively than that of 120-kVp-HIR (both p < 0.001). The highest CNR and subjective scores were attained in 80-kVp-DLR (all, p < 0.001). There were no significant differences in average NPS frequency and ERS between 120-kVp-HIR and 80-kVp-DLR (p ≥ 0.38). CONCLUSION: Compared with the 120-kVp-HIR protocol, the combined use of 80-kVp and DLR techniques yielded superior subjective and objective image quality with reduced radiation and ICM doses at thin-section abdominal CT. CLINICAL RELEVANCE STATEMENT: Scanning at low-tube voltage (80-kVp) combined with the deep-learning reconstruction algorithm may enhance diagnostic efficiency and patient safety by improving image quality and reducing radiation and contrast doses of thin-slice abdominal CT. KEY POINTS: Reducing radiation and iodine doses is desirable; however, contrast and noise degradation can be detrimental. The 80-kVp scan with the deep-learning reconstruction technique provided better images with lower radiation and contrast doses. This technique may be efficient for improving diagnostic confidence and patient safety in thin-slice abdominal CT.

3.
Br J Clin Pharmacol ; 90(3): 828-836, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-37953511

RESUMO

AIMS: Genotype-guided dosing algorithms can explain about half of the interindividual variability in prothrombin time-international normalized ratio (PT-INR) under warfarin treatment. This study aimed to refine a published kinetic-pharmacodynamic model and guide warfarin dosage for an optimal PT-INR based on renal function. METHODS: Using a retrospective cohort of adult patients (>20 years) who were administered warfarin and underwent PT-INR measurements, we refined the kinetic-pharmacodynamic model with age and the genotypes of cytochrome P450 2C9 and vitamin K epoxide reductase complex subunit 1 using the PRIOR subroutine in the nonlinear-mixed-effect modelling programme. We searched the significant covariates for parameters, such as the dose rate for 50% inhibition of coagulation (EDR50 ), using a stepwise forward and backward method. Monte Carlo simulation determined a required daily dose of warfarin with a target range of PT-INR (2.0-3.0 or 1.6-2.6) based on the significant covariates. RESULTS: A total of 350 patients with 2762 PT-INR measurements were enrolled (estimated glomerular filtration rate [eGFR]: 47.5 [range: 2.6-199.0] mL/min/1.73 m2 ). The final kinetic-pharmacodynamic model showed that the EDR50 changed power functionally with body surface area, serum albumin level and eGFR. Monte Carlo simulation revealed that a lower daily dose of warfarin was required to attain the target PT-INR range as eGFR decreased. CONCLUSIONS: Model-informed precision dosing of warfarin is a valuable approach for estimating its dosage in patients with renal impairment.


Assuntos
Anticoagulantes , Varfarina , Adulto , Humanos , Anticoagulantes/farmacocinética , Citocromo P-450 CYP2C9/genética , Genótipo , Coeficiente Internacional Normatizado , Japão , Protrombina , Tempo de Protrombina , Estudos Retrospectivos , Vitamina K Epóxido Redutases/genética , Varfarina/farmacocinética
4.
J Vasc Interv Radiol ; 35(7): 979-988.e1, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38537737

RESUMO

PURPOSE: To assess the different adjunctive catheter techniques required to achieve complete occlusion of renal arteriovenous malformations (rAVMs) of different angioarchitectural types. MATERIALS AND METHODS: Overall, data on 18 patients with rAVM (Type 1, n = 7; Type 2, n = 2; Type 3, n = 9; mean age, 53.8 years) who underwent 25 procedures between 2011 and 2022 were reviewed. The clinical presentations, endovascular techniques, arteriovenous malformation (AVM) occlusion rate, adverse events (including the incidence of renal infarction), and clinical symptoms and outcomes (including recurrence/increase of AVM) were analyzed according to the Cho-Do angioarchitectural classification. Posttreatment renal infarction was classified as no infarction, small infarction (<12.5%), medium infarction (12.5%-25%), and large infarction (>25%) using contrast-enhanced computed tomography or magnetic resonance imaging. RESULTS: Hematuria and heart failure were presenting symptoms in 10 and 2 patients, respectively. The embolic materials used were as follows: Type 1 rAVM, coils alone or with n-butyl-2-cyanoacrylate (nBCA); Type 2 rAVM, nBCA alone or with coils; and Type 3 rAVMs, nBCA alone. Fourteen patients underwent adjunctive catheter techniques, including flow control with a balloon catheter and multiple microcatheter placement, alone or in combination. Immediate postprocedural angiography revealed complete occlusion in 15 patients (83%) and marked regression of rAVM in 3 (17%). Small asymptomatic renal infarctions were observed in 6 patients with Type 3 rAVMs without any decrease in renal function. No major adverse events were observed. All symptomatic patients experienced symptom resolution. Recurrence/increase of rAVM was not observed during the mean 32-month follow-up period (range, 2-120 months). CONCLUSIONS: Transarterial embolization using adjunctive catheter techniques according to angioarchitectural types can be an effective treatment for rAVMs.


Assuntos
Malformações Arteriovenosas , Embolização Terapêutica , Artéria Renal , Veias Renais , Humanos , Pessoa de Meia-Idade , Feminino , Masculino , Embolização Terapêutica/efeitos adversos , Malformações Arteriovenosas/terapia , Malformações Arteriovenosas/diagnóstico por imagem , Resultado do Tratamento , Adulto , Estudos Retrospectivos , Idoso , Artéria Renal/diagnóstico por imagem , Artéria Renal/anormalidades , Veias Renais/diagnóstico por imagem , Veias Renais/anormalidades , Angiografia por Tomografia Computadorizada , Valor Preditivo dos Testes , Recidiva , Fatores de Tempo , Adulto Jovem , Fatores de Risco , Embucrilato/administração & dosagem , Infarto/diagnóstico por imagem , Infarto/etiologia , Infarto/terapia , Angiografia por Ressonância Magnética
5.
Neuroradiology ; 66(3): 325-332, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38200284

RESUMO

PURPOSE: Leptomeningeal enhancement (LME) suggests leptomeningeal dissemination (LMD) of tumor cells, which is a complication of end-stage glioblastoma, and is associated with a poor prognosis. However, magnetic resonance imaging (MRI) occasionally indicates the disappearance of peri-brainstem LME after surgical resection of glioblastoma. Since preoperative LMD may affect treatment indications, we aimed to analyze the clinical significance of preoperative LME of the brainstem in glioblastoma. METHODS: We retrospectively collected clinical and radiological data from consecutive patients with glioblastoma and preoperative LME of the brainstem, who were treated at our hospital between 2017 and 2020. RESULTS: Among 112 patients with glioblastoma, nine (8%) showed preoperative LME of the brainstem. In comparison with tumors without LME, tumor size was significantly associated with the preoperative LME of the brainstem (p = 0.016). In addition, there was a trend toward significance for a relationship between deep tumor location and preoperative LME of the brainstem (p = 0.058). Notably, among six patients who underwent surgical resection for glioblastoma with LME of the brainstem, four showed significant radiological disappearance of the LME on postoperative MRI. This suggests that the LME did not result from LMD in these cases. Moreover, these four patients lived longer than would be expected from the presence of LMD. However, this LME disappearance was not observed after biopsy or chemoradiotherapy. CONCLUSIONS: These findings suggest that preoperative LME does not necessarily indicate the presence of untreatable LMD; moreover, LME may disappear after surgical tumor resection. Thus, transient preoperative LME could be attributed to other mechanisms, including impaired venous flow due to intratumoral arteriovenous shunts, which can be resolved by reducing the tumor burden.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Humanos , Glioblastoma/diagnóstico por imagem , Glioblastoma/cirurgia , Glioblastoma/patologia , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Quimiorradioterapia , Tronco Encefálico/diagnóstico por imagem , Tronco Encefálico/cirurgia , Tronco Encefálico/patologia , Neoplasias Encefálicas/patologia
6.
Neuroradiology ; 66(7): 1123-1130, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38480538

RESUMO

PURPOSE: We aimed to evaluate the effect of deep learning-based reconstruction (DLR) on high-spatial-resolution three-dimensional T2-weighted fast asymmetric spin-echo (HR-3D T2-FASE) imaging in the preoperative evaluation of cerebellopontine angle (CPA) tumors. METHODS: This study included 13 consecutive patients who underwent preoperative HR-3D T2-FASE imaging using a 3 T MRI scanner. The reconstruction voxel size of HR-3D T2-FASE imaging was 0.23 × 0.23 × 0.5 mm. The contrast-to-noise ratios (CNRs) of the structures were compared between HR-3D T2-FASE images with and without DLR. The observers' preferences based on four categories on the tumor side on HR-3D T2-FASE images were evaluated. The facial nerve in relation to the tumor on HR-3D T2-FASE images was assessed with reference to intraoperative findings. RESULTS: The mean CNR between the tumor and trigeminal nerve and between the cerebrospinal fluid and trigeminal nerve was significantly higher for DLR images than non-DLR-based images (14.3 ± 8.9 vs. 12.0 ± 7.6, and 66.4 ± 12.0 vs. 53.9 ± 8.5, P < 0.001, respectively). The observer's preference for the depiction and delineation of the tumor, cranial nerves, vessels, and location relation on DLR HR-3D T2FASE images was superior to that on non-DLR HR-3D T2FASE images in 7 (54%), 6 (46%), 6 (46%), and 6 (46%) of 13 cases, respectively. The facial nerves around the tumor on HR-3D T2-FASE images were visualized accurately in five (38%) cases with DLR and in four (31%) without DLR. CONCLUSION: DLR HR-3D T2-FASE imaging is useful for the preoperative assessment of CPA tumors.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Cuidados Pré-Operatórios , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Idoso , Ângulo Cerebelopontino/diagnóstico por imagem , Ângulo Cerebelopontino/cirurgia , Neoplasias Cerebelares/diagnóstico por imagem , Neoplasias Cerebelares/cirurgia , Interpretação de Imagem Assistida por Computador/métodos , Estudos Retrospectivos , Neuroma Acústico/diagnóstico por imagem , Neuroma Acústico/cirurgia
7.
Neuroradiology ; 66(2): 217-226, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38148334

RESUMO

PURPOSE: The aim of this study is to assess the effect of super-resolution deep learning-based reconstruction (SR-DLR), which uses k-space properties, on image quality of intracranial time-of-flight (TOF) magnetic resonance angiography (MRA) at 3 T. METHODS: This retrospective study involved 35 patients who underwent intracranial TOF-MRA using a 3-T MRI system with SR-DLR based on k-space properties in October and November 2022. We reconstructed MRA with SR-DLR (matrix = 1008 × 1008) and MRA without SR-DLR (matrix = 336 × 336). We measured the signal-to-noise ratio (SNR), contrast, and contrast-to-noise ratio (CNR) in the basilar artery (BA) and the anterior cerebral artery (ACA) and the sharpness of the posterior cerebral artery (PCA) using the slope of the signal intensity profile curve at the half-peak points. Two radiologists evaluated image noise, artifacts, contrast, sharpness, and overall image quality of the two image types using a 4-point scale. We compared quantitative and qualitative scores between images with and without SR-DLR using the Wilcoxon signed-rank test. RESULTS: The SNRs, contrasts, and CNRs were all significantly higher in images with SR-DLR than those without SR-DLR (p < 0.001). The slope was significantly greater in images with SR-DLR than those without SR-DLR (p < 0.001). The qualitative scores in MRAs with SR-DLR were all significantly higher than MRAs without SR-DLR (p < 0.001). CONCLUSION: SR-DLR with k-space properties can offer the benefits of increased spatial resolution without the associated drawbacks of longer scan times and reduced SNR and CNR in intracranial MRA.


Assuntos
Aprendizado Profundo , Angiografia por Ressonância Magnética , Humanos , Angiografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
8.
J Comput Assist Tomogr ; 48(1): 85-91, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37531644

RESUMO

PURPOSE: This study aimed to predict contrast effects in cardiac computed tomography (CT) from CT localizer radiographs using a deep learning (DL) model and to compare the prediction performance of the DL model with that of conventional models based on patients' physical size. METHODS: This retrospective study included 473 (256 men and 217 women) cardiac CT scans between May 2014 and August 2017. We developed and evaluated DL models that predict milligrams of iodine per enhancement of the aorta from CT localizer radiographs. To assess the model performance, we calculated and compared Pearson correlation coefficient ( r ) between the actual iodine dose that was necessary to obtain a contrast effect of 1 HU (iodine dose per contrast effect [IDCE]) and IDCE predicted by DL, body weight, lean body weight, and body surface area of patients. RESULTS: The model was tested on 52 cases for the male group (mean [SD] age, 63.7 ± 11.4) and 44 cases for the female group (mean [SD] age, 69.8 ± 11.6). Correlation coefficients between the actual and predicted IDCE were 0.607 for the male group and 0.412 for the female group, which were higher than the correlation coefficients between the actual IDCE and body weight (0.539 for male, 0.290 for female), lean body weight (0.563 for male, 0.352 for female), and body surface area (0.587 for male, 0.349 for female). CONCLUSIONS: The performance for predicting contrast effects by analyzing CT localizer radiographs with the DL model was at least comparable with conventional methods using the patient's body size, notwithstanding that no additional measurements other than CT localizer radiographs were required.


Assuntos
Aprendizado Profundo , Iodo , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Estudos de Viabilidade , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Peso Corporal
9.
Artigo em Inglês | MEDLINE | ID: mdl-38346820

RESUMO

OBJECTIVE: The aim of this study was to assess the utility of the combined use of 3D wheel sampling and deep learning-based reconstruction (DLR) for intracranial high-resolution (HR)-time-of-flight (TOF)-magnetic resonance angiography (MRA) at 3 T. METHODS: This prospective study enrolled 20 patients who underwent head MRI at 3 T, including TOF-MRA. We used 3D wheel sampling called "fast 3D" and DLR for HR-TOF-MRA (spatial resolution, 0.39 × 0.59 × 0.5 mm3) in addition to conventional MRA (spatial resolution, 0.39 × 0.89 × 1 mm3). We compared contrast and contrast-to-noise ratio between the blood vessels (basilar artery and anterior cerebral artery) and brain parenchyma, full width at half maximum in the P3 segment of the posterior cerebral artery among 3 protocols. Two board-certified radiologists evaluated noise, contrast, sharpness, artifact, and overall image quality of 3 protocols. RESULTS: The contrast and contrast-to-noise ratio of fast 3D-HR-MRA with DLR are comparable or higher than those of conventional MRA and fast 3D-HR-MRA without DLR. The full width at half maximum was significantly lower in fast 3D-MRA with and without DLR than in conventional MRA (P = 0.006, P < 0.001). In qualitative evaluation, fast 3D-MRA with DLR had significantly higher sharpness and overall image quality than conventional MRA and fast 3D-MRA without DLR (sharpness: P = 0.021, P = 0.001; overall image quality: P = 0.029, P < 0.001). CONCLUSIONS: The combination of 3D wheel sampling and DLR can improve visualization of arteries in intracranial TOF-MRA.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38718419

RESUMO

OBJECTIVE: The purpose of this study was to evaluate the usefulness of the injection pressure-to-injection rate (IPIR) ratio for the early detection of contrast extravasation at the venipuncture site during contrast-enhanced computed tomography. METHODS: We retrospectively enrolled 57,528 patients who underwent contrast-enhanced computed tomography examinations in a single hospital. The power injector recorded the contrast injection pressure at 0.25-second intervals. We constructed logistic regression models using the IPIR ratio as the independent variable and extravasation occurrence as the dependent variable (IPIR ratio models) at 1, 2, 3, 4, 5, and 6 seconds after the start of contrast administration. Univariate logistic regression models in which injection pressure is used as an independent variable (injection pressure models) were also constructed as a reference baseline. The performance of the models was evaluated with the area under the receiver operating characteristic curves. RESULTS: Of the 57,528 cases, 46,022 were assigned to the training group and 11,506 were assigned to the test group, which included 112 extravasation cases (0.24%) in the training group and 28 (0.24%) in the test group. The area under the receiver operating characteristic curves for the IPIR ratio models and injection pressure models were 0.555 versus 0.563 at t = 1 (P = 0.270), 0.712 versus 0.678 at t = 2 (P = 0.305), 0.758 versus 0.693 at t = 3 (P = 0.032), 0.776 versus 0.688 at t = 4 (P = 0.005), 0.810 versus 0.699 at t = 5 (P = 0.002), and 0.811 versus 0.706 at t = 6 (P = 0.002). CONCLUSIONS: The IPIR ratio models perform better in detecting contrast extravasation at 3 to 6 seconds after the start of contrast administration than injection pressure models.

11.
J Obstet Gynaecol Res ; 50(3): 448-455, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38165071

RESUMO

AIM: This study aimed to investigate the safety and efficacy of tadalafil in protecting the fetus from hypoxic stress caused by repeated labor pains during delivery and preventing fetal hypoxic-ischemic encephalopathy. METHODS: The study used a three-case cohort approach. Three patients were administered 10 mg tadalafil and monitored for serious adverse events. In the absence of serious tadalafil-associated adverse events as assessed by the Safety Evaluation Committee, three new patients were added to the study and treated with 20 mg/dose. The blood levels of tadalafil were recorded before and after 2, 4, 8, and 12 h of administration and 2 h after delivery. RESULTS: A total of seven patients were enrolled, and after excluding one patient who delivered before 37 weeks, tadalafil was administered to six patients. Maternal adverse events were considered acceptable from the maternal perspective, with grade 1 headache, anorexia, and myalgia and no obstetrical complications after delivery at both doses. No serious neonatal adverse events were associated with tadalafil. Tadalafil blood levels remained stable at both doses. In addition, the level of soluble fms-like tyrosine kinase-1 did not alter, while that of the placental growth factor differed significantly before and after tadalafil administration. CONCLUSIONS: The study confirmed the safety of tadalafil administration during delivery for both mothers and newborns. The stable tadalafil blood levels confirmed the efficacy of the tested administration regime at 12 h interval. These findings would assist in conducting phase II trials to further verify the optimal dose and safety of tadalafil.


Assuntos
Feto , Trabalho de Parto , Recém-Nascido , Gravidez , Humanos , Feminino , Tadalafila/efeitos adversos , Fator de Crescimento Placentário , Cuidado Pré-Natal
12.
Int J Mol Sci ; 25(11)2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38891998

RESUMO

Approximately 30% of steroid-resistant nephrotic syndromes are attributed to monogenic disorders that involve 27 genes. Mutations in KANK family members have also been linked to nephrotic syndrome; however, the precise mechanism remains elusive. To investigate this, podocyte-specific Kank1 knockout mice were generated to examine phenotypic changes. In the initial assessment under normal conditions, Kank1 knockout mice showed no significant differences in the urinary albumin-creatinine ratio, blood urea nitrogen, serum creatinine levels, or histological features compared to controls. However, following kidney injury with adriamycin, podocyte-specific Kank1 knockout mice exhibited a significantly higher albumin-creatinine ratio and a significantly greater sclerotic index than control mice. Electron microscopy revealed more extensive foot process effacement in the knockout mice than in control mice. In addition, KANK1-deficient human podocytes showed increased detachment and apoptosis following adriamycin exposure. These findings suggest that KANK1 may play a protective role in mitigating podocyte damage under pathological conditions.


Assuntos
Proteínas do Citoesqueleto , Doxorrubicina , Camundongos Knockout , Podócitos , Podócitos/metabolismo , Podócitos/patologia , Animais , Camundongos , Humanos , Proteínas do Citoesqueleto/metabolismo , Proteínas do Citoesqueleto/genética , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Proteínas Adaptadoras de Transdução de Sinal/genética , Apoptose , Síndrome Nefrótica/metabolismo , Síndrome Nefrótica/genética , Síndrome Nefrótica/patologia , Masculino , Proteínas Supressoras de Tumor/metabolismo , Proteínas Supressoras de Tumor/genética
13.
Radiology ; 306(3): e220542, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36255307

RESUMO

Background Large studies on the diagnostic performance of CT-derived myocardial extracellular volume fraction (ECV) for detecting cardiac amyloidosis are lacking. A simple and practical index as a surrogate for CT ECV would be clinically useful. Purpose To compare the diagnostic performances between CT-derived myocardial ECV and myocardium-to-lumen signal ratio for the detection of cardiac amyloidosis in a large patient sample. Materials and Methods This retrospective study included patients who underwent CT ECV analysis because of suspected heart failure or cardiomyopathy between January 2018 and July 2021. CT ECV was quantified using routine pre-transcatheter aortic valve replacement planning cardiac CT, pre-atrial fibrillation ablation planning cardiac CT, or coronary CT angiography with the addition of unenhanced and delayed phase cardiac CT scans. The diagnostic performances of CT ECV and myocardium-to-lumen signal ratio in delayed phase cardiac CT (a simplified index not requiring unenhanced CT and hematocrit) for detecting cardiac amyloidosis were evaluated using the area under the receiver operating characteristic curve (AUC), sensitivity, and specificity. Results Of 552 patients (mean age, 69 years ± 14 [SD]; 295 men), 41 had cardiac amyloidosis. The sensitivity of CT ECV for amyloidosis was 90% (37 of 41 patients [95% CI: 77, 97]), with a specificity of 92% (472 of 511 patients [95% CI: 90, 95]) and optimal ECV cutoff value of 37% (AUC, 0.97 [95% CI: 0.96, 0.99]). The sensitivity of myocardium-to-lumen signal ratio was 88% (36 of 41 patients [95% CI: 74, 96]), with a specificity of 92% (469 of 511 patients [95% CI: 89, 94]) and optimal myocardium-to-lumen signal ratio cutoff value of 0.87 (AUC, 0.96 [95% CI: 0.94, 0.97]; P = .27 for comparison with ECV). Conclusion CT-derived myocardial extracellular volume fraction and myocardium-to-lumen signal ratio showed comparable and excellent diagnostic performance in detecting cardiac amyloidosis in a large patient sample. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Williams in this issue.


Assuntos
Amiloidose , Cardiomiopatias , Masculino , Humanos , Idoso , Estudos Retrospectivos , Miocárdio , Amiloidose/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Valor Preditivo dos Testes , Imagem Cinética por Ressonância Magnética/métodos
14.
Liver Transpl ; 29(12): 1292-1303, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37540170

RESUMO

Hepatic venous outflow obstruction (HVOO) is a rare but critical vascular complication after adult living donor liver transplantation. We categorized HVOOs according to their morphology (anastomotic stenosis, kinking, and intrahepatic stenosis) and onset (early-onset < 3 mo vs. late-onset ≥ 3 mo). Overall, 16/324 (4.9%) patients developed HVOO between 2000 and 2020. Fifteen patients underwent interventional radiology. Of the 16 hepatic venous anastomoses within these 15 patients, 12 were anastomotic stenosis, 2 were kinking, and 2 were intrahepatic stenoses. All of the kinking and intrahepatic stenoses required stent placement, but most of the anastomotic stenoses (11/12, 92%) were successfully managed with balloon angioplasty, which avoided stent placement. Graft survival tended to be worse for patients with late-onset HVOO than early-onset HVOO (40% vs. 69.3% at 5 y, p = 0.162) despite successful interventional radiology. In conclusion, repeat balloon angioplasty can be considered for simple anastomotic stenosis, but stent placement is recommended for kinking or intrahepatic stenosis. Close follow-up is recommended in patients with late-onset HVOO even after successful treatment.


Assuntos
Angioplastia com Balão , Síndrome de Budd-Chiari , Transplante de Fígado , Humanos , Adulto , Síndrome de Budd-Chiari/diagnóstico por imagem , Síndrome de Budd-Chiari/etiologia , Síndrome de Budd-Chiari/terapia , Transplante de Fígado/efeitos adversos , Constrição Patológica/etiologia , Constrição Patológica/terapia , Doadores Vivos , Resultado do Tratamento , Stents/efeitos adversos , Veias Hepáticas/diagnóstico por imagem , Veias Hepáticas/cirurgia , Angioplastia com Balão/efeitos adversos
15.
Eur Radiol ; 33(11): 7923-7933, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37284863

RESUMO

OBJECTIVES: As a novel follow-up method for intracranial aneurysms treated with stent-assisted coil embolization (SACE), we developed four-dimensional magnetic resonance angiography (MRA) with minimized acoustic noise utilizing ultrashort-echo time (4D mUTE-MRA). We aimed to assess whether 4D mUTE-MRA is useful for the evaluation of intracranial aneurysms treated with SACE. METHODS: This study included 31 consecutive patients with intracranial aneurysm treated with SACE who underwent 4D mUTE-MRA at 3 T and digital subtraction angiography (DSA). For 4D mUTE-MRA, five dynamic MRA images with a spatial resolution of 0.5 × 0.5 × 0.5 mm3 were obtained every 200 ms. Two readers independently reviewed the 4D mUTE-MRA images to evaluate the aneurysm occlusion status (total occlusion, residual neck, and residual aneurysm) and the flow in the stent using a 4-point scale (from 1 [not visible] to 4 [excellent]). The interobserver and intermodality agreement was assessed using κ statistics. RESULTS: On DSA images, 10 aneurysms were classified as total occlusion, 14 as residual neck, and 7 as residual aneurysm. In terms of aneurysm occlusion status, the intermodality and interobserver agreement was excellent (κ = 0.92 and κ = 0.96, respectively). For the flow in the stents on 4D mUTE-MRA, the mean score was significantly higher for single stents than multiple stents (p < .001) and for open-cell type stents than closed-cell type (p < .01). CONCLUSIONS: 4D mUTE-MRA is a useful tool with a high spatial and temporal resolution for the evaluation of intracranial aneurysms treated with SACE. KEY POINTS: • In the evaluation of intracranial aneurysms treated with SACE on 4D mUTE-MRA and DSA, the intermodality and interobserver agreement in aneurysm occlusion status was excellent. • 4D mUTE-MRA shows good to excellent visualization of flow in the stents, especially for cases treated with a single or open-cell stent. • 4D mUTE-MRA can provide hemodynamic information related to embolized aneurysms and the distal arteries to stented parent arteries.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Seguimentos , Embolização Terapêutica/métodos , Angiografia por Ressonância Magnética/métodos , Stents , Angiografia Digital/métodos , Resultado do Tratamento
16.
Eur Radiol ; 33(11): 7585-7594, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37178197

RESUMO

OBJECTIVES: To evaluate the image quality of the 3D hybrid profile order technique and deep-learning-based reconstruction (DLR) for 3D magnetic resonance cholangiopancreatography (MRCP) within a single breath-hold (BH) at 3 T magnetic resonance imaging (MRI). METHODS: This retrospective study included 32 patients with biliary and pancreatic disorders. BH images were reconstructed with and without DLR. The signal-to-noise ratio (SNR), contrast, contrast-to-noise ratio (CNR) between the common bile duct (CBD) and periductal tissues, and full width at half maximum (FWHM) of CBD on 3D-MRCP were evaluated quantitatively. Two radiologists scored image noise, contrast, artifacts, blur, and overall image quality of the three image types using a 4-point scale. Quantitative and qualitative scores were compared using the Friedman test and post hoc Nemenyi test. RESULTS: The SNR and CNR were not significantly different when under respiratory gating- and BH-MRCP without DLR. However, they were significantly higher under BH with DLR than under respiratory gating (SNR, p = 0.013; CNR, p = 0.027). The contrast and FWHM of MRCP under BH with and without DLR were lower than those under respiratory gating (contrast, p < 0.001; FWHM, p = 0.015). Qualitative scores for noise, blur, and overall image quality were higher under BH with DLR than those under respiratory gating (blur, p = 0.003; overall, p = 0.008). CONCLUSIONS: The combination of the 3D hybrid profile order technique and DLR is useful for MRCP within a single BH and does not lead to the deterioration of image quality and space resolution at 3 T MRI. CLINICAL RELEVANCE STATEMENT: Considering its advantages, this sequence might become the standard protocol for MRCP in clinical practice, at least at 3.0 T. KEY POINTS: • The 3D hybrid profile order can achieve MRCP within a single breath-hold without a decrease in spatial resolution. • The DLR significantly improved the CNR and SNR of BH-MRCP. • The 3D hybrid profile order technique with DLR reduces the deterioration of image quality in MRCP within a single breath-hold.


Assuntos
Colangiopancreatografia por Ressonância Magnética , Aprendizado Profundo , Humanos , Colangiopancreatografia por Ressonância Magnética/métodos , Estudos Retrospectivos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos
17.
Eur Radiol ; 33(12): 8488-8500, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37432405

RESUMO

OBJECTIVES: To evaluate the effect of super-resolution deep-learning-based reconstruction (SR-DLR) on the image quality of coronary CT angiography (CCTA). METHODS: Forty-one patients who underwent CCTA using a 320-row scanner were retrospectively included. Images were reconstructed with hybrid (HIR), model-based iterative reconstruction (MBIR), normal-resolution deep-learning-based reconstruction (NR-DLR), and SR-DLR algorithms. For each image series, image noise, and contrast-to-noise ratio (CNR) at the left main trunk, right coronary artery, left anterior descending artery, and left circumflex artery were quantified. Blooming artifacts from calcified plaques were measured. Image sharpness, noise magnitude, noise texture, edge smoothness, overall quality, and delineation of the coronary wall, calcified and noncalcified plaques, cardiac muscle, and valves were subjectively ranked on a 4-point scale (1, worst; 4, best). The quantitative parameters and subjective scores were compared among the four reconstructions. Task-based image quality was assessed with a physical evaluation phantom. The detectability index for the objects simulating the coronary lumen, calcified plaques, and noncalcified plaques was calculated from the noise power spectrum (NPS) and task-based transfer function (TTF). RESULTS: SR-DLR yielded significantly lower image noise and blooming artifacts with higher CNR than HIR, MBIR, and NR-DLR (all p < 0.001). The best subjective scores for all the evaluation criteria were attained with SR-DLR, with significant differences from all other reconstructions (p < 0.001). In the phantom study, SR-DLR provided the highest NPS average frequency, TTF50%, and detectability for all task objects. CONCLUSION: SR-DLR considerably improved the subjective and objective image qualities and object detectability of CCTA relative to HIR, MBIR, and NR-DLR algorithms. CLINICAL RELEVANCE STATEMENT: The novel SR-DLR algorithm has the potential to facilitate accurate assessment of coronary artery disease on CCTA by providing excellent image quality in terms of spatial resolution, noise characteristics, and object detectability. KEY POINTS: • SR-DLR designed for CCTA improved image sharpness, noise property, and delineation of cardiac structures with reduced blooming artifacts from calcified plaques relative to HIR, MBIR, and NR-DLR. • In the task-based image-quality assessments, SR-DLR yielded better spatial resolution, noise property, and detectability for objects simulating the coronary lumen, coronary calcifications, and noncalcified plaques than other reconstruction techniques. • The image reconstruction times of SR-DLR were shorter than those of MBIR, potentially serving as a novel standard-of-care reconstruction technique for CCTA performed on a 320-row CT scanner.


Assuntos
Aprendizado Profundo , Placa Aterosclerótica , Humanos , Angiografia por Tomografia Computadorizada , Estudos Retrospectivos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Angiografia Coronária , Algoritmos
18.
Eur Radiol ; 33(5): 3253-3265, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36973431

RESUMO

OBJECTIVES: To evaluate the image quality of deep learning-based reconstruction (DLR), model-based (MBIR), and hybrid iterative reconstruction (HIR) algorithms for lower-dose (LD) unenhanced head CT and compare it with those of standard-dose (STD) HIR images. METHODS: This retrospective study included 114 patients who underwent unenhanced head CT using the STD (n = 57) or LD (n = 57) protocol on a 320-row CT. STD images were reconstructed with HIR; LD images were reconstructed with HIR (LD-HIR), MBIR (LD-MBIR), and DLR (LD-DLR). The image noise, gray and white matter (GM-WM) contrast, and contrast-to-noise ratio (CNR) at the basal ganglia and posterior fossa levels were quantified. The noise magnitude, noise texture, GM-WM contrast, image sharpness, streak artifact, and subjective acceptability were independently scored by three radiologists (1 = worst, 5 = best). The lesion conspicuity of LD-HIR, LD-MBIR, and LD-DLR was ranked through side-by-side assessments (1 = worst, 3 = best). Reconstruction times of three algorithms were measured. RESULTS: The effective dose of LD was 25% lower than that of STD. Lower image noise, higher GM-WM contrast, and higher CNR were observed in LD-DLR and LD-MBIR than those in STD (all, p ≤ 0.035). Compared with STD, the noise texture, image sharpness, and subjective acceptability were inferior for LD-MBIR and superior for LD-DLR (all, p < 0.001). The lesion conspicuity of LD-DLR (2.9 ± 0.2) was higher than that of HIR (1.2 ± 0.3) and MBIR (1.8 ± 0.4) (all, p < 0.001). Reconstruction times of HIR, MBIR, and DLR were 11 ± 1, 319 ± 17, and 24 ± 1 s, respectively. CONCLUSION: DLR can enhance the image quality of head CT while preserving low radiation dose level and short reconstruction time. KEY POINTS: • For unenhanced head CT, DLR reduced the image noise and improved the GM-WM contrast and lesion delineation without sacrificing the natural noise texture and image sharpness relative to HIR. • The subjective and objective image quality of DLR was better than that of HIR even at 25% reduced dose without considerably increasing the image reconstruction times (24 s vs. 11 s). • Despite the strong noise reduction and improved GM-WM contrast performance, MBIR degraded the noise texture, sharpness, and subjective acceptance with prolonged reconstruction times relative to HIR, potentially hampering its feasibility.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Algoritmos , Aprendizado Profundo , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Cabeça/diagnóstico por imagem
19.
Br J Clin Pharmacol ; 89(6): 1852-1861, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36640105

RESUMO

AIMS: Diabetes mellitus affects the pharmacokinetics of cytochrome P450 3A4/5 (CYP3A4/5) substrates. We evaluated the relationship between haemoglobin A1c (HbA1c) levels and the pharmacokinetics of controlled-release tacrolimus. METHODS: This retrospective observational cohort study included kidney transplant recipients (>18 years) receiving controlled-release tacrolimus orally. CYP3A5 genotypes were categorized as expressers (*1/*1 or *1/*3) and non-expressers (*3/*3). Multiple linear regression analysis determined the predictors for trough concentration/dose-normalized by body weight (C/D) ratio of tacrolimus at 7 days, 6 months and 12 months after administration. Correlations between the C/D ratio and HbA1c levels at baseline, 6 and 12 months after tacrolimus initiation were evaluated with Bonferroni correction. RESULTS: Out of 42 patients (CYP3A5 expressers, n = 17, and non-expressers, n = 25), the multiple linear regression analysis showed that the C/D ratio on Day 7 was marginally higher in CYP3A5 non-expressers than in CYP3A5 expressers (r = .43, P = .028). Factors affecting the elevation of tacrolimus C/D ratio after 6 and 12 months of treatment were male sex and CYP3A5 non-expressers (r = .59, P < .001) and increased HbA1c levels and CYP3A5 non-expressers (r = .62, P < .001), respectively. The C/D ratio and HbA1c levels after 12 months was positively correlated in CYP3A5 non-expressers (y = 54.6x - 194.6, r = .63, P = .004, Bonferroni correction). Furthermore, intra-individual changes in the C/D ratio and HbA1c levels from 6 to 12 months were nearly correlated (y = 54.5x + 20.2, r = .41, P = .036, Bonferroni correction). CONCLUSION: HbA1c and CYP3A5 genotypes might be considered to understand the inter- and intra-individual variability in blood tacrolimus concentrations after 6 months post-kidney transplantation.


Assuntos
Controle Glicêmico , Transplante de Rim , Humanos , Adulto , Masculino , Feminino , Citocromo P-450 CYP3A/genética , Tacrolimo , Preparações de Ação Retardada , Hemoglobinas Glicadas , Estudos Retrospectivos
20.
AJR Am J Roentgenol ; 221(5): 599-610, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37377362

RESUMO

BACKGROUND. A super-resolution deep learning reconstruction (SR-DLR) algorithm may provide better image sharpness than earlier reconstruction algorithms and thereby improve coronary stent assessment on coronary CTA. OBJECTIVE. The purpose of our study was to compare SR-DLR and other reconstruction algorithms in terms of image quality measures related to coronary stent evaluation in patients undergoing coronary CTA. METHODS. This retrospective study included patients with at least one coronary artery stent who underwent coronary CTA between January 2020 and December 2020. Examinations were performed using a 320-row normal-resolution scanner and were reconstructed with hybrid iterative reconstruction (HIR), model-based iterative reconstruction (MBIR), normal-resolution deep learning reconstruction (NR-DLR), and SR-DLR algorithms. Quantitative image quality measures were determined. Two radiologists independently reviewed images to rank the four reconstructions (4-point scale: 1 = worst reconstruction, 4 = best reconstruction) for qualitative measures and to score diagnostic confidence (5-point scale: score ≥ 3 indicating an assessable stent). The assessability rate was calculated for stents with a diameter of 3.0 mm or less. RESULTS. The sample included 24 patients (18 men, six women; mean age, 72.5 ± 9.8 [SD] years), with 51 stents. SR-DLR, in comparison with the other reconstructions, yielded lower stent-related blooming artifacts (median, 40.3 vs 53.4-58.2), stent-induced attenuation increase ratio (0.17 vs 0.27-0.31), and quantitative image noise (18.1 vs 20.9-30.4 HU) and higher in-stent lumen diameter (2.4 vs 1.7-1.9 mm), stent strut sharpness (327 vs 147-210 ΔHU/mm), and CNR (30.0 vs 16.0-25.6) (all p < .001). For both observers, all ranked measures (image sharpness; image noise; noise texture; delineation of stent strut, in-stent lumen, coronary artery wall, and calcified plaque surrounding the stent) and diagnostic confidence showed a higher score for SR-DLR (median, 4.0 for all features) than for the other reconstructions (range, 1.0-3.0) (all p < .001). The assessability rate for stents with a diameter of 3.0 mm or less (n = 37) was higher for SR-DLR (86.5% for observer 1 and 89.2% for observer 2) than for HIR (35.1% and 43.2%), MBIR (59.5% and 62.2%), and NR-DLR (62.2% and 64.9%) (all p < .05). CONCLUSION. SR-DLR yielded improved delineation of the stent strut and in-stent lumen, with better image sharpness and less image noise and blooming artifacts, in comparison with HIR, MBIR, and NR-DLR. CLINICAL IMPACT. SR-DLR may facilitate coronary stent assessment on a 320-row normal-resolution scanner, particularly for small-diameter stents.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA