Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 389(16): 1477-1487, 2023 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-37634149

RESUMO

BACKGROUND: Imaging-guided percutaneous coronary intervention (PCI) is associated with better clinical outcomes than angiography-guided PCI. Whether routine optical coherence tomography (OCT) guidance in PCI of lesions involving coronary-artery branch points (bifurcations) improves clinical outcomes as compared with angiographic guidance is uncertain. METHODS: We conducted a multicenter, randomized, open-label trial at 38 centers in Europe. Patients with a clinical indication for PCI and a complex bifurcation lesion identified by means of coronary angiography were randomly assigned in a 1:1 ratio to OCT-guided PCI or angiography-guided PCI. The primary end point was a composite of major adverse cardiac events (MACE), defined as death from a cardiac cause, target-lesion myocardial infarction, or ischemia-driven target-lesion revascularization at a median follow-up of 2 years. RESULTS: We assigned 1201 patients to OCT-guided PCI (600 patients) or angiography-guided PCI (601 patients). A total of 111 patients (18.5%) in the OCT-guided PCI group and 116 (19.3%) in the angiography-guided PCI group had a bifurcation lesion involving the left main coronary artery. At 2 years, a primary end-point event had occurred in 59 patients (10.1%) in the OCT-guided PCI group and in 83 patients (14.1%) in the angiography-guided PCI group (hazard ratio, 0.70; 95% confidence interval, 0.50 to 0.98; P = 0.035). Procedure-related complications occurred in 41 patients (6.8%) in the OCT-guided PCI group and 34 patients (5.7%) in the angiography-guided PCI group. CONCLUSIONS: Among patients with complex coronary-artery bifurcation lesions, OCT-guided PCI was associated with a lower incidence of MACE at 2 years than angiography-guided PCI. (Funded by Abbott Vascular and others; OCTOBER ClinicalTrials.gov number, NCT03171311.).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Humanos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Tomografia de Coerência Óptica/efeitos adversos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Europa (Continente)
2.
Circulation ; 149(17): 1328-1338, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38465592

RESUMO

BACKGROUND: Diabetes may be associated with differential outcomes in patients undergoing left main coronary revascularization with percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). The aim of this study was to investigate outcomes in patients with left main disease with and without diabetes randomized to PCI versus CABG. METHODS: Individual patient data were pooled from 4 trials (SYNTAX [Synergy Between PCI With Taxus and Cardiac Surgery], PRECOMBAT [Premier of Randomized Comparison of Bypass Surgery Versus Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease], NOBLE [Nordic-Baltic-British Left Main Revascularisation Study], and EXCEL [Evaluation of XIENCE Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization]) that randomized patients with left main disease to PCI or CABG. Patients were considered suitable for either approach. Patients were categorized by diabetes status. Kaplan-Meier event rates, Cox model hazard ratios, and interactions were assessed. RESULTS: Among 4393 patients, 1104 (25.1%) had diabetes. Patients with diabetes experienced higher rates of 5-year death (158/1104 [Kaplan-Meier rate, 14.7%] versus 297/3289 [9.3%]; P<0.001), spontaneous myocardial infarction (MI; 67/1104 [6.7%] versus 114/3289 [3.7%]; P<0.001), and repeat revascularization (189/1104 [18.5%] versus 410/3289 [13.2%]; P<0.001). Rates of all-cause mortality did not differ after PCI versus CABG in those with (84/563 [15.3%] versus 74/541 [14.1%]; hazard ratio, 1.11 [95% CI, 0.82-1.52]) or without (155/1634 [9.7%] versus 142/1655 [8.9%]; hazard ratio, 1.08 [95% CI, 0.86-1.36; PintHR=0.87) diabetes. Rates of stroke within 1 year were lower with PCI versus CABG in the entire population, with no heterogeneity based on diabetes status (PintHR=0.51). The 5-year rates of spontaneous MI and repeat coronary revascularization were higher after PCI regardless of diabetes status (spontaneous MI: 45/563 [8.9%] versus 22/541 [4.4%] in diabetes and 82/1634 [5.3%] versus 32/1655 [2.1%] in no diabetes, PintHR=0.47; repeat revascularization: 127/563 [24.5%] versus 62/541 [12.4%] in diabetes and 254/1634 [16.3%] versus 156/1655 [10.1%] in no diabetes, PintHR=0.18). For spontaneous MI and repeat revascularization, there were greater absolute risk differences beyond 1 year in patients with diabetes (4.9% and 9.9%) compared with those without (2.1% and 4.3%; PintARD=0.047 and 0.016). CONCLUSIONS: In patients with left main disease considered equally suitable for PCI or CABG and with largely low to intermediate SYNTAX scores, diabetes was associated with higher rates of death and cardiovascular events through 5 years. Compared with CABG, PCI resulted in no difference in the risk of death and a lower risk of early stroke regardless of diabetes status, and a higher risk of spontaneous MI and repeat coronary revascularization, with larger late absolute excess risks in patients with diabetes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT01205776, NCT0146651, NCT00422968, and NCT00114972.

3.
Lancet ; 403(10429): 824-837, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38401549

RESUMO

BACKGROUND: Previous meta-analyses have shown reduced risks of composite adverse events with intravascular imaging-guided percutaneous coronary intervention (PCI) compared with angiography guidance alone. However, these studies have been insufficiently powered to show whether all-cause death or all myocardial infarction are reduced with intravascular imaging guidance, and most previous intravascular imaging studies were done with intravascular ultrasound rather than optical coherence tomography (OCT), a newer imaging modality. We aimed to assess the comparative performance of intravascular imaging-guided PCI and angiography-guided PCI with drug-eluting stents. METHODS: For this systematic review and updated meta-analysis, we searched the MEDLINE, Embase, and Cochrane databases from inception to Aug 30, 2023, for studies that randomly assigned patients undergoing PCI with drug-eluting stents either to intravascular ultrasound or OCT, or both, or to angiography alone to guide the intervention. The searches were done and study-level data were extracted independently by two investigators. The primary endpoint was target lesion failure, defined as the composite of cardiac death, target vessel-myocardial infarction (TV-MI), or target lesion revascularisation, assessed in patients randomly assigned to intravascular imaging guidance (intravascular ultrasound or OCT) versus angiography guidance. We did a standard frequentist meta-analysis to generate direct data, and a network meta-analysis to generate indirect data and overall treatment effects. Outcomes were expressed as relative risks (RRs) with 95% CIs at the longest reported follow-up duration. This study was registered with the international prospective register of systematic reviews (PROSPERO, number CRD42023455662). FINDINGS: 22 trials were identified in which 15 964 patients were randomised and followed for a weighted mean duration of 24·7 months (longest duration of follow-up in each study ranging from 6 to 60 months). Compared with angiography-guided PCI, intravascular imaging-guided PCI resulted in a decreased risk of target lesion failure (RR 0·71 [95% CI 0·63-0·80]; p<0·0001), driven by reductions in the risks of cardiac death (RR 0·55 [95% CI 0·41-0·75]; p=0·0001), TV-MI (RR 0·82 [95% CI 0·68-0·98]; p=0·030), and target lesion revascularisation (RR 0·72 [95% CI 0·60-0·86]; p=0·0002). Intravascular imaging guidance also reduced the risks of stent thrombosis (RR 0·52 [95% CI 0·34-0·81]; p=0·0036), all myocardial infarction (RR 0·83 [95% CI 0·71-0·99]; p=0·033), and all-cause death (RR 0·75 [95% CI 0·60-0·93]; p=0·0091). Outcomes were similar for OCT-guided and intravascular ultrasound-guided PCI. INTERPRETATION: Compared with angiography guidance, intravascular imaging guidance of coronary stent implantation with OCT or intravascular ultrasound enhances both the safety and effectiveness of PCI, reducing the risks of death, myocardial infarction, repeat revascularisation, and stent thrombosis. FUNDING: Abbott.


Assuntos
Stents Farmacológicos , Eritema Multiforme , Infarto do Miocárdio , Intervenção Coronária Percutânea , Trombose , Humanos , Angiografia , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Catheter Cardiovasc Interv ; 101(4): 787-797, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36740229

RESUMO

AIMS: Early healing after drug-eluting stent (DES) implantation may reduce the risk of stent thrombosis. The aim of this study was to compare patterns of early healing after implantation of the thin strut everolimus-eluting Synergy DES (Boston Scientific) or the biolimus-eluting Biomatix Neoflex DES (Biosensors). METHODS AND RESULTS: A total of 160 patients with the chronic or acute coronary syndrome were randomized 1:1 to Synergy or Biomatrix DES. Optical coherence tomography (OCT) was performed at baseline and at either 1- or 3-month follow-up. The primary endpoint was a coronary stent healing index (CSHI), a weighted index of strut coverage, neointimal hyperplasia, malapposition, and extrastent lumen. A total of 133 cases had OCT follow-up and 119 qualified for matched OCT analysis. The median CSHI score did neither differ significantly between the groups at 1 month: Synergy 8.0 (interquartile range [IQR]: 3.0; 14.0) versus Biomatrix 8.5 (IQR: 4.0; 15.0) (p = 0.47) nor at 3 months: Synergy 6.5 (IQR: 2.0; 13.0) versus Biomatrix 6.0 (IQR: 4.0; 11.0) (p = 0.83). Strut coverage was 84.6% (IQR: 72.0; 97.9) for Synergy versus 77.6% (IQR: 70.1; 90.3) for Biomatrix (p = 0.15) at 1 month and 90.3% (IQR 79.0; 98.8) (Synergy) versus 83.9% (IQR: 77.5; 92.6) (Biomatrix) (p = 0.068) at 3 months. Pooled 1- and 3-month coverage was 88.6% (IQR: 74.4; 98.4) for Synergy compared with 80.7% (IQR: 73.2; 90.8) for Biomatrix (p = 0.02). CONCLUSIONS: The early healing response after treatment with the Synergy or Biomatrix DES did not differ significantly as determined by a healing index. The Synergy DES showed overall better early stent strut coverage.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo , Doença da Artéria Coronariana/terapia , Polímeros , Implantes Absorvíveis , Resultado do Tratamento , Desenho de Prótese , Tomografia de Coerência Óptica
5.
Lancet ; 398(10318): 2247-2257, 2021 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-34793745

RESUMO

BACKGROUND: The optimal revascularisation strategy for patients with left main coronary artery disease is uncertain. We therefore aimed to evaluate long-term outcomes for patients treated with percutaneous coronary intervention (PCI) with drug-eluting stents versus coronary artery bypass grafting (CABG). METHODS: In this individual patient data meta-analysis, we searched MEDLINE, Embase, and the Cochrane database using the search terms "left main", "percutaneous coronary intervention" or "stent", and "coronary artery bypass graft*" to identify randomised controlled trials (RCTs) published in English between database inception and Aug 31, 2021, comparing PCI with drug-eluting stents with CABG in patients with left main coronary artery disease that had at least 5 years of patient follow-up for all-cause mortality. Two authors (MSS and BAB) identified studies meeting the criteria. The primary endpoint was 5-year all-cause mortality. Secondary endpoints were cardiovascular death, spontaneous myocardial infarction, procedural myocardial infarction, stroke, and repeat revascularisation. We used a one-stage approach; event rates were calculated by use of the Kaplan-Meier method and treatment group comparisons were made by use of a Cox frailty model, with trial as a random effect. In Bayesian analyses, the probabilities of absolute risk differences in the primary endpoint between PCI and CABG being more than 0·0%, and at least 1·0%, 2·5%, or 5·0%, were calculated. FINDINGS: Our literature search yielded 1599 results, of which four RCTs-SYNTAX, PRECOMBAT, NOBLE, and EXCEL-meeting our inclusion criteria were included in our meta-analysis. 4394 patients, with a median SYNTAX score of 25·0 (IQR 18·0-31·0), were randomly assigned to PCI (n=2197) or CABG (n=2197). The Kaplan-Meier estimate of 5-year all-cause death was 11·2% (95% CI 9·9-12·6) with PCI and 10·2% (9·0-11·6) with CABG (hazard ratio 1·10, 95% CI 0·91-1·32; p=0·33), resulting in a non-statistically significant absolute risk difference of 0·9% (95% CI -0·9 to 2·8). In Bayesian analyses, there was an 85·7% probability that death at 5 years was greater with PCI than with CABG; this difference was more likely than not less than 1·0% (<0·2% per year). The numerical difference in mortality was comprised more of non-cardiovascular than cardiovascular death. Spontaneous myocardial infarction (6·2%, 95% CI 5·2-7·3 vs 2·6%, 2·0-3·4; hazard ratio [HR] 2·35, 95% CI 1·71-3·23; p<0·0001) and repeat revascularisation (18·3%, 16·7-20·0 vs 10·7%, 9·4-12·1; HR 1·78, 1·51-2·10; p<0·0001) were more common with PCI than with CABG. Differences in procedural myocardial infarction between strategies depended on the definition used. Overall, there was no difference in the risk of stroke between PCI (2·7%, 2·0-3·5) and CABG (3·1%, 2·4-3·9; HR 0·84, 0·59-1·21; p=0·36), but the risk was lower with PCI in the first year after randomisation (HR 0·37, 0·19-0·69). INTERPRETATION: Among patients with left main coronary artery disease and, largely, low or intermediate coronary anatomical complexity, there was no statistically significant difference in 5-year all-cause death between PCI and CABG, although a Bayesian approach suggested a difference probably exists (more likely than not <0·2% per year) favouring CABG. There were trade-offs in terms of the risk of myocardial infarction, stroke, and revascularisation. A heart team approach to communicate expected outcome differences might be useful to assist patients in reaching a treatment decision. FUNDING: No external funding.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto
7.
Catheter Cardiovasc Interv ; 99(4): 1075-1083, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34967094

RESUMO

OBJECTIVES: To evaluate the feasibility, safety, and healing response of a magnesium-based bioresorbable scaffold (BRS) in the treatment of simple bifurcation lesions using the single stent provisional technique. BACKGROUND: BRS may hold potential advantages in the treatment of coronary bifurcation lesions, however low radial strength and expansion capacity has been an issue with polymer-based scaffolds. The magnesium BRS may prove suitable for bifurcation treatment as its mechanical properties are closer to those of permanent metallic drug-eluting stents. METHODS: The study was a proof-of-concept study with planned inclusion of 20 patients with stable angina pectoris and a bifurcation lesion involving a large side branch (SB) > 2.5 mm with less than 50% diameter stenosis. Procedure and healing response were evaluated by optical coherence tomography (OCT). The main endpoints were a composite clinical safety endpoint and an OCT healing index at 1 month (range: 0-98). RESULTS: Eleven patients were included in the study. The study was prematurely terminated due to scaffold fractures and embolization of scaffold fragments in three cases requiring bailout stenting with drug-eluting stents. One patient underwent bypass surgery at 3 months due to stenosis proximal to the study segment. All SB were patent for 1 month. One-month OCT evaluation showed strut coverage of 96.9% and no malapposition. Scaffold fractures and uncovered jailing struts resulted in a less favorable mean OCT healing index score of 10.4 ± 9.0. CONCLUSIONS: Implanting a magnesium scaffold by the provisional technique in nontrue bifurcation lesions was associated with scaffold fracture, embolization of scaffold fragments, and a high need for bailout stenting.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Implantes Absorvíveis , Constrição Patológica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Magnésio , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 99(1): 68-73, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33533535

RESUMO

OBJECTIVES: This study aims to evaluate the diagnostic performance of quantitative flow ratio (QFR) pre transcatheter aortic valve implantation (TAVI) in patients with aortic valve stenosis (AS) and coronary artery disease (CAD). Post-TAVI fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) was used as reference. BACKGROUND: CAD is prevalent in patients with AS, but the hemodynamics of AS confounds evaluation using pressure wire-based assessments. QFR might be less sensitive to the presence of AS thereby allowing for CAD evaluation before aortic valve replacement. Further, QFR does not require the use of pressure wire and therefore has the potential for reducing costs and complications related to insertion of a coronary pressure wire. METHODS: The diagnostic performance of QFR in coronary angiograms from 28 patients undergoing TAVI was evaluated. In all patients, both FFR and iFR were measured pre- and immediately post-TAVI while QFR was measured pre-TAVI. RESULTS: Using post-TAVI FFR and iFR as reference the diagnostic accuracy of pre-TAVI QFR were 83% (95%CI; 68-97) and 52% (95%CI; 30-74) p = .008, respectively. CONCLUSIONS: Pre-TAVI QFR showed a good diagnostic performance using post-TAVI FFR as reference. QFR could become a wire-free, safe, and quick way of evaluating CAD in patients with severe AS undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários , Humanos , Valor Preditivo dos Testes , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
BMC Cardiovasc Disord ; 22(1): 68, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35196986

RESUMO

BACKGROUND: Complications related to femoral artery access for coronary angiography (CAG) is a safety concern. Vascular closure devices (VCDs) have been developed to reduce the rate of complications after femoral artery access. We compared the safety and efficacy of the MynxGrip VCD versus manual compression (MC) after femoral access CAG in a randomized controlled trial. METHODS: The study was a randomized, single center, non-blinded, two-arm non-inferiority trial. The study was stopped prematurely because of low inclusion rate. RESULTS: We randomized 869 patients to closure with the MynxGrip VCD or MC and 865 entered analyses. The incidence of the primary endpoint of major adverse vascular events (MAVE) after 30 days was 1.2% in the MynxGrip group and 0% in the MC group (p = 0.06). The median time to hemostasis was 4 [3:5] minutes and 10 [7:11] minutes in the MynxGrip group and MC group, respectively (p < 0.0001). The corresponding median times to mobilization was 73 [65:87] minutes and 76 [70:88] minutes (p = 0.01). CONCLUSIONS: MAVE was rare after closure of femoral arterial access by both the MynxGrip VCD and MC. We found a numerical difference in favour of MC but this did not reach statistical significance. Time to hemostasis was shorter in the MynxGrip group when compared to the MC group. TRIAL REGISTRATION: The study was approved by the local medical ethics committee and registered at clinicaltrials.org (ClinicalTrials identifier: NCT02237430 11/09/2014).


Assuntos
Dispositivos de Oclusão Vascular , Angiografia Coronária/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Técnicas Hemostáticas/efeitos adversos , Humanos , Punções , Fatores de Tempo , Resultado do Tratamento , Dispositivos de Oclusão Vascular/efeitos adversos
10.
Lancet ; 395(10219): 191-199, 2020 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-31879028

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is increasingly used in revascularisation of patients with left main coronary artery disease in place of the standard treatment, coronary artery bypass grafting (CABG). The NOBLE trial aimed to evaluate whether PCI was non-inferior to CABG in the treatment of left main coronary artery disease and reported outcomes after a median follow-up of 3·1 years. We now report updated 5-year outcomes of the trial. METHODS: The prospective, randomised, open-label, non-inferiority NOBLE trial was done at 36 hospitals in nine northern European countries. Patients with left main coronary artery disease requiring revascularisation were enrolled and randomly assigned (1:1) to receive PCI or CABG. The primary endpoint was major adverse cardiac or cerebrovascular events (MACCE), a composite of all-cause mortality, non-procedural myocardial infarction, repeat revascularisation, and stroke. Non-inferiority of PCI to CABG was defined as the upper limit of the 95% CI of the hazard ratio (HR) not exceeding 1·35 after 275 MACCE had occurred. Secondary endpoints included all-cause mortality, non-procedural myocardial infarction, and repeat revascularisation. Outcomes were analysed in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, NCT01496651. FINDINGS: Between Dec 9, 2008, and Jan 21, 2015, 1201 patients were enrolled and allocated to PCI (n=598) or CABG (n=603), with 17 subsequently lost to early follow-up. 592 patients in each group were included in this analysis. At a median of 4·9 years of follow-up, the predefined number of events was reached for adequate power to assess the primary endpoint. Kaplan-Meier 5-year estimates of MACCE were 28% (165 events) for PCI and 19% (110 events) for CABG (HR 1·58 [95% CI 1·24-2·01]); the HR exceeded the limit for non-inferiority of PCI compared to CABG. CABG was found to be superior to PCI for the primary composite endpoint (p=0·0002). All-cause mortality was estimated in 9% after PCI versus 9% after CABG (HR 1·08 [95% CI 0·74-1·59]; p=0·68); non-procedural myocardial infarction was estimated in 8% after PCI versus 3% after CABG (HR 2·99 [95% CI 1·66-5·39]; p=0·0002); and repeat revascularisation was estimated in 17% after PCI versus 10% after CABG (HR 1·73 [95% CI 1·25-2·40]; p=0·0009). INTERPRETATION: In revascularisation of left main coronary artery disease, PCI was associated with an inferior clinical outcome at 5 years compared with CABG. Mortality was similar after the two procedures but patients treated with PCI had higher rates of non-procedural myocardial infarction and repeat revascularisation. FUNDING: Biosensors.


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Intervenção Coronária Percutânea , Idoso , Causas de Morte , Ponte de Artéria Coronária/efeitos adversos , Reestenose Coronária/cirurgia , Stents Farmacológicos , Estudos de Equivalência como Asunto , Oclusão de Enxerto Vascular , Humanos , Pessoa de Meia-Idade , Infarto do Miocárdio , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias , Estudos Prospectivos , Acidente Vascular Cerebral , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 96(1): 31-39, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32087046

RESUMO

OBJECTIVES: In a coronary bifurcation bench model, to determine the effects of side branch (SB) wire crossing position and balloon position on the stent scaffolding after the final proximal optimization technique (POT). BACKGROUND: POT performed as a final step after SB dilatation or kissing balloon inflation (KBI) has been widely advocated despite limited evidence. METHODS: Thirty-one stent implantations in bifurcation phantoms were performed using a one-stent provisional technique with (KBI) (n = 13), with POT-side-POT technique (n = 12) or with the two-stent culotte technique (n = 6). SB wiring was performed through either a proximal or a distal stent cell and confirmed by optical coherence tomography. Final POT was performed with the balloon positioned either across or proximal to the SB takeoff. The area of the opened stent cell in front of the SB was assessed by 3D reconstructed microcomputation tomography scans performed before and after Final POT. RESULTS: In cases with metallic carina, final POT across the SB takeoff caused SB rejailing. Regardless of stent technique and wire position, a Final POT across the SB takeoff reduced the SB cell opening area by 43% [32%;58%] (n = 15). The largest reduction (54-70%) was found after the POT-side-POT technique in procedures with a proximal wiring. Final POT performed proximal to the SB takeoff caused limited or no SB cell opening area reduction (4% [0.6%;6%] [n = 16]). CONCLUSION: Final POT with balloon positioned across the SB takeoff in a narrow angle bifurcation reduces largest stent cell area in front of the SB ostium and may cause SB rejailing in cases with metallic carina.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Vasos Coronários , Stents Farmacológicos , Angioplastia Coronária com Balão/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Humanos , Teste de Materiais , Modelos Anatômicos , Modelos Cardiovasculares , Desenho de Prótese
12.
Catheter Cardiovasc Interv ; 96(7): E674-E682, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31710149

RESUMO

OBJECTIVES: To compare on the bench the physical and mechanical properties of Magmaris, a magnesium bioresorbable scaffold (BRS), with Absorb and DESolve polymeric BRS and a permanent metallic stent. BACKGROUND: Understanding the mechanical and physical properties of BRS is crucial for appropriate implantation and postdilatation. METHODS: Testing was performed in fluid at 37°C and in silicone bifurcation phantoms with a 30° angle between main branch (MB) and side branch. RESULTS: The 3.0-mm Magmaris BRS did not fracture after MB postdilatation up to 4.4 mm in contrast to the Absorb where the safe postdilatation diameter was 3.7 mm. For dilatation through stent cells, there were no Magmaris fractures with 3.0-mm noncompliant (NC) balloons inflated to nominal pressure. Mini-kissing balloon postdilatation with two 3.0-mm NC balloons up to 17 atm was without fracture except for an outlier. Longitudinal and radial strengths were similar for Magmaris and Absorb BRS. The crossing profile for the Magmaris was larger than other devices. Recoil 120 min after deployment was the greatest for Magmaris but 120 min after 3.5 mm postdilatation all devices had similar diameters. CONCLUSIONS: The Magmaris BRS was more resistant to strut fracture than Absorb. It had a larger crossing profile than other devices and similar radial and longitudinal strengths to Absorb. While recoil after deployment was greater with Magmaris, 120 min after 3.5 mm postdilatation all devices had similar diameters.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Magnésio , Angioplastia Coronária com Balão/efeitos adversos , Análise de Falha de Equipamento , Teste de Materiais , Desenho de Prótese , Falha de Prótese , Estresse Mecânico
13.
Lancet ; 391(10124): 939-948, 2018 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-29478841

RESUMO

BACKGROUND: Numerous randomised trials have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI) for patients with coronary artery disease. However, no studies have been powered to detect a difference in mortality between the revascularisation strategies. METHODS: We did a systematic review up to July 19, 2017, to identify randomised clinical trials comparing CABG with PCI using stents. Eligible studies included patients with multivessel or left main coronary artery disease who did not present with acute myocardial infarction, did PCI with stents (bare-metal or drug-eluting), and had more than 1 year of follow-up for all-cause mortality. In a collaborative, pooled analysis of individual patient data from the identified trials, we estimated all-cause mortality up to 5 years using Kaplan-Meier analyses and compared PCI with CABG using a random-effects Cox proportional-hazards model stratified by trial. Consistency of treatment effect was explored in subgroup analyses, with subgroups defined according to baseline clinical and anatomical characteristics. FINDINGS: We included 11 randomised trials involving 11 518 patients selected by heart teams who were assigned to PCI (n=5753) or to CABG (n=5765). 976 patients died over a mean follow-up of 3·8 years (SD 1·4). Mean Synergy between PCI with Taxus and Cardiac Surgery (SYNTAX) score was 26·0 (SD 9·5), with 1798 (22·1%) of 8138 patients having a SYNTAX score of 33 or higher. 5 year all-cause mortality was 11·2% after PCI and 9·2% after CABG (hazard ratio [HR] 1·20, 95% CI 1·06-1·37; p=0·0038). 5 year all-cause mortality was significantly different between the interventions in patients with multivessel disease (11·5% after PCI vs 8·9% after CABG; HR 1·28, 95% CI 1·09-1·49; p=0·0019), including in those with diabetes (15·5% vs 10·0%; 1·48, 1·19-1·84; p=0·0004), but not in those without diabetes (8·7% vs 8·0%; 1·08, 0·86-1·36; p=0·49). SYNTAX score had a significant effect on the difference between the interventions in multivessel disease. 5 year all-cause mortality was similar between the interventions in patients with left main disease (10·7% after PCI vs 10·5% after CABG; 1·07, 0·87-1·33; p=0·52), regardless of diabetes status and SYNTAX score. INTERPRETATION: CABG had a mortality benefit over PCI in patients with multivessel disease, particularly those with diabetes and higher coronary complexity. No benefit for CABG over PCI was seen in patients with left main disease. Longer follow-up is needed to better define mortality differences between the revascularisation strategies. FUNDING: None.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Stents , Humanos , Taxa de Sobrevida , Resultado do Tratamento
14.
Eur Heart J ; 39(35): 3281-3300, 2018 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-29790954

RESUMO

This Consensus Document is the first of two reports summarizing the views of an expert panel organized by the European Association of Percutaneous Cardiovascular Interventions (EAPCI) on the clinical use of intracoronary imaging including intravascular ultrasound (IVUS) and optical coherence tomography (OCT). The first document appraises the role of intracoronary imaging to guide percutaneous coronary interventions (PCIs) in clinical practice. Current evidence regarding the impact of intracoronary imaging guidance on cardiovascular outcomes is summarized, and patients or lesions most likely to derive clinical benefit from an imaging-guided intervention are identified. The relevance of the use of IVUS or OCT prior to PCI for optimizing stent sizing (stent length and diameter) and planning the procedural strategy is discussed. Regarding post-implantation imaging, the consensus group recommends key parameters that characterize an optimal PCI result and provides cut-offs to guide corrective measures and optimize the stenting result. Moreover, routine performance of intracoronary imaging in patients with stent failure (restenosis or stent thrombosis) is recommended. Finally, strengths and limitations of IVUS and OCT for guiding PCI and assessing stent failures and areas that warrant further research are critically discussed.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção , Angiografia Coronária , Oclusão de Enxerto Vascular , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Complicações Pós-Operatórias , Falha de Prótese , Stents/efeitos adversos , Resultado do Tratamento
15.
Eur Heart J ; 39(35): 3314-3321, 2018 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-30137305

RESUMO

Aims: Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. Methods and results: A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. Conclusion: The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.


Assuntos
Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Teorema de Bayes , Humanos , Sensibilidade e Especificidade
16.
Circ J ; 82(6): 1575-1583, 2018 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-29576586

RESUMO

BACKGROUND: Development of methods for accurate reconstruction of bioresorbable scaffolds (BRS) and assessing local hemodynamics is crucial for investigation of vascular healing after BRS implantation.Methods and Results:Patients with BRS that crossed over in a coronary bifurcation were included for analysis. Reconstructions of the coronary lumen and BRS were performed by fusion of optical coherence tomography and coronary angiography generating a tree model (TM) and a hybrid model with BRS (TM-BRS). A virtual BRS model with thinner struts was created and all 3 models were analyzed using computational fluid dynamics to derive: (1) time-average shear stress (TASS), (2) TASS gradient (TASSG), which represents SS heterogeneity, and (3) fractional flow reserve (FFR). Reconstruction of the BRS was successful in all 10 patients. TASS and TASSG were both higher by TM-BRS than by TM in main vessels (difference 0.27±4.30 Pa and 10.18±27.28 Pa/mm, P<0.001), with a remarkable difference at side branch ostia (difference 13.51±17.40 Pa and 81.65±105.19 Pa/mm, P<0.001). With thinner struts, TASS was lower on the strut surface but higher at the inter-strut zones, whereas TASSG was lower in both regions (P<0.001 for all). Computational FFR was lower by TM-BRS than by TM for both main vessels and side branches (P<0.001). CONCLUSIONS: Neglecting BRS reconstruction leads to significantly lower SS and SS heterogeneity, which is most pronounced at side branch ostia. Thinner struts can marginally reduce SS heterogeneity.


Assuntos
Implantes Absorvíveis , Hemodinâmica , Modelos Cardiovasculares , Alicerces Teciduais , Idoso , Angiografia Coronária/métodos , Vasos Coronários/cirurgia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Estresse Mecânico , Tomografia de Coerência Óptica/métodos , Cicatrização
17.
Lancet ; 388(10061): 2743-2752, 2016 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-27810312

RESUMO

BACKGROUND: Coronary artery bypass grafting (CABG) is the standard treatment for revascularisation in patients with left main coronary artery disease, but use of percutaneous coronary intervention (PCI) for this indication is increasing. We aimed to compare PCI and CABG for treatment of left main coronary artery disease. METHODS: In this prospective, randomised, open-label, non-inferiority trial, patients with left main coronary artery disease were enrolled in 36 centres in northern Europe and randomised 1:1 to treatment with PCI or CABG. Eligible patients had stable angina pectoris, unstable angina pectoris, or non-ST-elevation myocardial infarction. Exclusion criteria were ST-elevation myocardial infarction within 24 h, being considered too high risk for CABG or PCI, or expected survival of less than 1 year. The primary endpoint was major adverse cardiac or cerebrovascular events (MACCE), a composite of all-cause mortality, non-procedural myocardial infarction, any repeat coronary revascularisation, and stroke. Non-inferiority of PCI to CABG required the lower end of the 95% CI not to exceed a hazard ratio (HR) of 1·35 after up to 5 years of follow-up. The intention-to-treat principle was used in the analysis if not specified otherwise. This trial is registered with ClinicalTrials.gov identifier, number NCT01496651. FINDINGS: Between Dec 9, 2008, and Jan 21, 2015, 1201 patients were randomly assigned, 598 to PCI and 603 to CABG, and 592 in each group entered analysis by intention to treat. Kaplan-Meier 5 year estimates of MACCE were 29% for PCI (121 events) and 19% for CABG (81 events), HR 1·48 (95% CI 1·11-1·96), exceeding the limit for non-inferiority, and CABG was significantly better than PCI (p=0·0066). As-treated estimates were 28% versus 19% (1·55, 1·18-2·04, p=0·0015). Comparing PCI with CABG, 5 year estimates were 12% versus 9% (1·07, 0·67-1·72, p=0·77) for all-cause mortality, 7% versus 2% (2·88, 1·40-5·90, p=0·0040) for non-procedural myocardial infarction, 16% versus 10% (1·50, 1·04-2·17, p=0·032) for any revascularisation, and 5% versus 2% (2·25, 0·93-5·48, p=0·073) for stroke. INTERPRETATION: The findings of this study suggest that CABG might be better than PCI for treatment of left main stem coronary artery disease. FUNDING: Biosensors, Aarhus University Hospital, and participating sites.


Assuntos
Angioplastia Coronária com Balão , Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/métodos , Idoso , Doença da Artéria Coronariana/mortalidade , Stents Farmacológicos/normas , Europa (Continente) , Feminino , Humanos , Masculino , Infarto do Miocárdio , Acidente Vascular Cerebral , Resultado do Tratamento
18.
Am Heart J ; 190: 54-63, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28760214

RESUMO

Some but not all randomized controlled trials (RCT) have suggested that percutaneous coronary intervention (PCI) with drug-eluting stents may be an acceptable alternative to coronary artery bypass grafting (CABG) surgery for the treatment of unprotected left main coronary artery disease (ULMCAD). We therefore aimed to compare the risk of all-cause mortality between PCI and CABG in patients with ULMCAD in a pairwise meta-analysis of RCT. METHODS: Randomized controlled trials comparing PCI vs CABG for the treatment of ULMCAD were searched through MEDLINE, EMBASE, Cochrane databases, and proceedings of international meetings. RESULTS: Six trials including 4,686 randomized patients were identified. After a median follow-up of 39 months, there were no significant differences between PCI vs CABG in the risk of all-cause mortality (hazard ratio [HR] 0.99, 95% CI 0.76-1.30) or cardiac mortality. However, a significant interaction for cardiac mortality (Pinteraction= .03) was apparent between randomization arm and SYNTAX score, such that the relative risk for mortality tended to be lower with PCI compared with CABG among patients in the lower SYNTAX score tertile, similar in the intermediate tertile, and higher in the upper SYNTAX score tertile. Percutaneous coronary intervention compared with CABG was associated with a similar long-term composite risk of death, myocardial infarction, or stroke (HR 1.06, 95% CI 0.82-1.37), with fewer events within 30 days after PCI offset by fewer events after 30 days with CABG (Pinteraction < .0001). Percutaneous coronary intervention was associated with greater rates of unplanned revascularization compared with CABG (HR 1.74, 95% CI 1.47-2.07). CONCLUSIONS: In patients undergoing revascularization for ULMCAD, PCI was associated with similar rates of mortality compared with CABG at a median follow-up of 39 months, but with an interaction effect suggesting relatively lower mortality with PCI in patients with low SYNTAX score and relatively lower mortality with CABG in patients with high SYNTAX score. Both procedures resulted in similar long-term composite rates of death, myocardial infarction, or stroke, with PCI offering an early safety advantage and CABG demonstrating greater durability.


Assuntos
Ponte de Artéria Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/epidemiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Causas de Morte/tendências , Doença da Artéria Coronariana/mortalidade , Saúde Global , Humanos , Incidência , Taxa de Sobrevida/tendências
19.
Eur Heart J ; 37(24): 1923-8, 2016 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-27161619

RESUMO

AIMS: Randomized trials of coronary bifurcation stenting have shown better outcomes from a simple (provisional) strategy rather than a complex (planned two-stent) strategy in terms of short-term efficacy and safety. Here, we report the 5-year all-cause mortality based on pooled patient-level data from two large bifurcation coronary stenting trials with similar methodology: the Nordic Bifurcation Study (NORDIC I) and the British Bifurcation Coronary Study: old, new, and evolving strategies (BBC ONE). METHODS AND RESULTS: Both multicentre randomized trials compared simple (provisional T-stenting) vs. complex (culotte, crush, and T-stenting) techniques, using drug-eluting stents. We analysed all-cause death at 5 years. Data were collected from phone follow-up, hospital records, and national mortality tracking. Follow-up was complete for 890 out of 913 patients (97%). Both Simple and Complex groups were similar in terms of patient and lesion characteristics. Five-year mortality was lower among patients who underwent a simple strategy rather than a complex strategy [17 patients (3.8%) vs. 31 patients (7.0%); P = 0.04]. CONCLUSION: For coronary bifurcation lesions, a provisional single-stent approach appears to be associated with lower long-term mortality than a systematic dual stenting technique.


Assuntos
Stents , Doença da Artéria Coronariana , Humanos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA