RESUMO
Theranostics has become a major area of innovation and progress in cancer care over the last decade. In view of the introduction of approved therapeutics in neuroendocrine tumours and prostate cancer in the last 10 years, the ability to provide access to these treatments has emerged as a key factor in ensuring global benefits from this cancer therapy approach. In this Series paper we explore the issues that affect access to and availability of theranostic radiopharmaceuticals, including supply and regulatory issues that might affect the availability of theranostic treatments for patients with cancer.
Assuntos
Compostos Radiofarmacêuticos , Nanomedicina Teranóstica , Humanos , Compostos Radiofarmacêuticos/uso terapêutico , Neoplasias/terapia , Medicina de PrecisãoRESUMO
Following on from the 2015 Lancet Oncology Commission on expanding global access to radiotherapy, Radiotherapy and theranostics: a Lancet Oncology Commission was created to assess the access and availability of radiotherapy to date and to address the important issue of access to the promising field of theranostics at a global level. A marked disparity in the availability of radiotherapy machines between high-income countries and low-income and middle-income countries (LMICs) has been identified previously and remains a major problem. The availability of a suitably trained and credentialled workforce has also been highlighted as a major limiting factor to effective implementation of radiotherapy, particularly in LMICs. We investigated initiatives that could mitigate these issues in radiotherapy, such as extended treatment hours, hypofractionation protocols, and new technologies. The broad implementation of hypofractionation techniques compared with conventional radiotherapy in prostate cancer and breast cancer was projected to provide radiotherapy for an additional 2·2 million patients (0·8 million patients with prostate cancer and 1·4 million patients with breast cancer) with existing resources, highlighting the importance of implementing new technologies in LMICs. A global survey undertaken for this Commission revealed that use of radiopharmaceutical therapy-other than 131I-was highly variable in high-income countries and LMICs, with supply chains, workforces, and regulatory issues affecting access and availability. The capacity for radioisotope production was highlighted as a key issue, and training and credentialling of health professionals involved in theranostics is required to ensure equitable access and availability for patient treatment. New initiatives-such as the International Atomic Energy Agency's Rays of Hope programme-and interest by international development banks in investing in radiotherapy should be supported by health-care systems and governments, and extended to accelerate the momentum generated by recognising global disparities in access to radiotherapy. In this Commission, we propose actions and investments that could enhance access to radiotherapy and theranostics worldwide, particularly in LMICs, to realise health and economic benefits and reduce the burden of cancer by accessing these treatments.
Assuntos
Acessibilidade aos Serviços de Saúde , Neoplasias , Humanos , Neoplasias/radioterapia , Países em Desenvolvimento , Radioterapia/economia , Nanomedicina Teranóstica , Disparidades em Assistência à Saúde , Radioterapia (Especialidade)/economia , Radioterapia (Especialidade)/educaçãoRESUMO
BACKGROUND: In the rapidly evolving field of nuclear medicine, the paramount importance of radiation protection, safety, and quality systems cannot be overstated. This document provides a comprehensive analysis of the intricate regulatory frameworks and guidelines, meticulously crafted and updated by national and international regulatory bodies to ensure the utmost safety and efficiency in the practice of nuclear medicine. METHODS: We explore the dynamic nature of these regulations, emphasizing their adaptability in accommodating technological advancements and the integration of nuclear medicine with other medical and scientific disciplines. RESULTS: Audits, both internal and external, are spotlighted for their pivotal role in assessing and ensuring compliance with established standards, promoting a culture of continuous improvement and excellence. We delve into the significant contributions of entities like the International Atomic Energy Agency (IAEA) and relevant professional societies in offering universally applicable guidelines that amalgamate the latest in scientific research, ethical considerations, and practical applicability. CONCLUSIONS: The document underscores the essence of international collaborations in pooling expertise, resources, and insights, fostering a global community of practice where knowledge and innovations are shared. Readers will gain an in-depth understanding of the practical applications, challenges, and opportunities presented by these regulatory frameworks and audit processes. The ultimate goal is to inspire and inform ongoing efforts to enhance safety, quality, and effectiveness in nuclear medicine globally.
Assuntos
Medicina Nuclear , Proteção Radiológica , Medicina Nuclear/normas , Proteção Radiológica/normas , Humanos , Controle de Qualidade , SegurançaRESUMO
Medical imaging is both valuable and essential in the care of patients. Much of this imaging depends on ionizing radiation with attendant responsibilities for judicious use when performing an examination. This responsibility applies in settings of both individual as well as multiple (recurrent) imaging with associated repeated radiation exposures. In addressing the roles and responsibilities of the medical communities in the paradigm of recurrent imaging, both the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) have issued position statements, each affirmed by other organizations. The apparent difference in focus and approach has resulted in a lack of clarity and continued debate. Aiming towards a coherent approach in dealing with radiation exposure in recurrent imaging, the IAEA convened a panel of experts, the purpose of which was to identify common ground and reconcile divergent perspectives. The effort has led to clarifying recommendations for radiation exposure aspects of recurrent imaging, including the relevance of patient agency and the provider-patient covenant in clinical decision-making. CLINICAL RELEVANCE STATEMENT: An increasing awareness, generating some lack of clarity and divergence in perspectives, with patients receiving relatively high radiation doses (e.g., ≥ 100 mSv) from recurrent imaging warrants a multi-stakeholder accord for the benefit of patients, providers, and the imaging community. KEY POINTS: ⢠Recurrent medical imaging can result in an accumulation of exposures which exceeds 100 milli Sieverts. ⢠Professional organizations have different perspectives on roles and responsibilities for recurrent imaging. ⢠An expert panel reconciles differing perspectives for addressing radiation exposure from recurrent medical imaging.
Assuntos
Diagnóstico por Imagem , Exposição à Radiação , Humanos , Diagnóstico por Imagem/métodos , Exposição à Radiação/prevenção & controle , Doses de Radiação , Proteção Radiológica/métodosRESUMO
In March 2021 the International Atomic Energy Agency (IAEA) organised an online Technical Meeting on Developing Effective Methods for Radiation Protection Education and Training of Health Professionals with attendance of 230 participants representing 66 Member States and 24 international organizations, professional bodies and safety alliances. By means of a pre-meeting survey, presentations by experts, topical panel discussions and post-meeting feedback to the meeting summary, the meeting identified strengths, common weaknesses and possible solutions and actions for improving radiation protection education and training of health professionals. Available guidelines and resources for radiation protection training were also reviewed. The meeting discussion resulted in a strong consensus for the need of: (a) international guidance on education and training in radiation protection and safety for health professionals, (b) an international description of minimum standards of initial and ongoing competence and qualification in radiation protection for relevant professional groups, considering the available recommendations at international and regional levels. The proposed actions include provisions for train-the-trainer credentialing and facility training accreditation, balance betwee the online and face-to-face training, improved on-the job training, as well as improved inclusion in training programmes of aspects related to application of new technologies, ethical aspects, development of communication skills, and use of software tools for improving justification and optimisation. The need for making the ongoing training practical, applicable, and useful to the trainee was highlighted. The international consultation initiated by the IAEA was appreciated as a good approach to understand and promote coordination and collaboration at all levels, for best results in education and training in radiation protection of health professionals. Implementing such a holistic approach to education and training in radiation protection would contribute towards qualification and competence of health professionals needed to ensure application of high standards for quality and safety in medical uses of ionizing radiation.
Assuntos
Energia Nuclear , Proteção Radiológica , Humanos , Agências InternacionaisRESUMO
The purpose of this IAEA-coordinated international study was to understand aspects related to the communication of radiation risk from imaging studies, such as how often imaging department personnel and referring physicians are asked about radiation risks in diagnostic imaging, who asks about these risks, how often professionals are able to provide satisfactory answers using qualitative metrics and how often quantitative risk estimates are needed. A web-based questionnaire with ten questions was completed by 386 healthcare professionals from 63 countries from all four continents, including clinicians/referring physicians (42.5%), radiologists or nuclear medicine physicians (26.7%), medical physicists (23.1%), radiographers/radiological technologists (6.2%) and others (1.6%). The results indicate that radiation risk-related questions are largely asked by patients (73.1%) and parents of child patients (38.6%), and 78% of the professionals believe they are able to answer those questions using qualitative metrics such as very small/minimal, small, medium rather than number of cancers likely occurring. The vast majority, with over three times higher frequency, indicated the purpose of knowing previous radiological exams as 'both clinical information and radiation exposure history' rather than 'only clinical information'. Nearly two-thirds of the clinicians/referring physicians indicated that knowing the radiation exposure history of the patient will affect their decision-making for the next exam, as against only about one-fifth who said 'no, it will not affect their decision-making'. The same question, when addressed to radiologists, resulted in a slightly larger fraction of about three-quarters who said 'yes', as opposed to a smaller fraction of about 12% who said 'no, it will not affect their decision-making'. Mapping the present situation of communication of benefits and risks for patients is important and may be the basis of further analysis, regular monitoring and possibly a target for clinical audits. Further studies focused on specific professional groups might help in obtaining á deeper understanding of the need for practical communication tools.
Assuntos
Comunicação , Exposição à Radiação , Criança , Diagnóstico por Imagem/efeitos adversos , Humanos , Pais , Inquéritos e QuestionáriosRESUMO
The diagnosis and treatment of patients with cancer requires access to imaging to ensure accurate management decisions and optimal outcomes. Our global assessment of imaging and nuclear medicine resources identified substantial shortages in equipment and workforce, particularly in low-income and middle-income countries (LMICs). A microsimulation model of 11 cancers showed that the scale-up of imaging would avert 3·2% (2·46 million) of all 76·0 million deaths caused by the modelled cancers worldwide between 2020 and 2030, saving 54·92 million life-years. A comprehensive scale-up of imaging, treatment, and care quality would avert 9·55 million (12·5%) of all cancer deaths caused by the modelled cancers worldwide, saving 232·30 million life-years. Scale-up of imaging would cost US$6·84 billion in 2020-30 but yield lifetime productivity gains of $1·23 trillion worldwide, a net return of $179·19 per $1 invested. Combining the scale-up of imaging, treatment, and quality of care would provide a net benefit of $2·66 trillion and a net return of $12·43 per $1 invested. With the use of a conservative approach regarding human capital, the scale-up of imaging alone would provide a net benefit of $209·46 billion and net return of $31·61 per $1 invested. With comprehensive scale-up, the worldwide net benefit using the human capital approach is $340·42 billion and the return per dollar invested is $2·46. These improved health and economic outcomes hold true across all geographical regions. We propose actions and investments that would enhance access to imaging equipment, workforce capacity, digital technology, radiopharmaceuticals, and research and training programmes in LMICs, to produce massive health and economic benefits and reduce the burden of cancer globally.
Assuntos
Países em Desenvolvimento/economia , Diagnóstico por Imagem/economia , Neoplasias/economia , Medicina Nuclear/economia , Efeitos Psicossociais da Doença , Custos de Cuidados de Saúde , Humanos , Neoplasias/diagnóstico , Pobreza , Radiografia/economiaRESUMO
Background There is lack of guidance on specific CT protocols for imaging patients with coronavirus disease 2019 (COVID-19) pneumonia. Purpose To assess international variations in CT utilization, protocols, and radiation doses in patients with COVID-19 pneumonia. Materials and Methods In this retrospective data collection study, the International Atomic Energy Agency coordinated a survey between May and July 2020 regarding CT utilization, protocols, and radiation doses from 62 health care sites in 34 countries across five continents for CT examinations performed in patients with COVID-19 pneumonia. The questionnaire obtained information on local prevalence, method of diagnosis, most frequent imaging, indications for CT, and specific policies on use of CT in COVID-19 pneumonia. Collected data included general information (patient age, weight, clinical indication), CT equipment (CT make and model, year of installation, number of detector rows), scan protocols (body region, scan phases, tube current and potential), and radiation dose descriptors (CT dose index and dose length product). Descriptive statistics and generalized estimating equations were performed. Results Data from 782 patients (median age, 59 years [interquartile range, 15 years]) from 54 health care sites in 28 countries were evaluated. Less than one-half of the health care sites used CT for initial diagnosis of COVID-19 pneumonia and three-fourths used CT for assessing disease severity. CT dose index varied based on CT vendors (7-11 mGy; P < .001), number of detector rows (8-9 mGy; P < .001), year of CT installation (7-10 mGy; P = .006), and reconstruction techniques (7-10 mGy; P = .03). Multiphase chest CT examinations performed at 20% of sites (11 of 54) were associated with higher dose length product compared with single-phase chest CT examinations performed in 80% of sites (43 of 54) (P = .008). Conclusion CT use, scan protocols, and radiation doses in patients with coronavirus disease 2019 pneumonia showed wide variation across health care sites within the same and between different countries. Many patients were imaged multiple times and/or with multiphase CT scan protocols. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Lee in this issue.
Assuntos
COVID-19/diagnóstico por imagem , Protocolos Clínicos , Internacionalidade , Pulmão/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , SARS-CoV-2RESUMO
High-dose radiation exposures of humans occur every year around the world, and may lead to harmful tissue reactions. This review aims to look at the available information sources that can help answering the question of how often these events occur yearly on a global scale. In the absence of comprehensive databases of global occurrence, publications on radiation accidents in all uses of radiation and on rates of high-dose events in different medical uses of radiation have been reviewed. Most high-dose radiation exposures seem to occur in the medical uses of radiation, reflecting the high number of medical exposures performed. In therapeutic medical uses, radiation doses are purposely often given at levels known to cause deterministic effects, and there is a very narrow range in which the medical practitioner can operate without causing severe unacceptable outcomes. In interventional medical uses, there are scenarios in which the radiation dose given to a patient may reach or exceed a threshold for skin effects, where this radiation dose may be unavoidable, considering all benefits and risks as well as benefits and risks of any alternative procedures. Regardless of if the delivered dose is unintended, unnecessary or unavoidable, there are estimates published of the rates of high-dose events and of radiation-induced tissue injuries occurring in medical uses. If this information is extrapolated to a global scenario, noting the inherent limitations in doing so, it does not seem unreasonable to expect that the global number of radiation-induced injuries every year may be in the order of hundreds, likely mainly arising from medical uses of radiation, and in particular from interventional fluoroscopy procedures and external beam radiotherapy procedures. These procedures are so frequently employed throughout the world that even a very small rate of radiation-induced injuries becomes a substantial number when scaled up to a global level.
Assuntos
Lesões por Radiação , Proteção Radiológica , Liberação Nociva de Radioativos , Fluoroscopia , Humanos , Doses de Radiação , Lesões por Radiação/epidemiologia , Lesões por Radiação/etiologia , PeleRESUMO
The global pandemic of coronavirus disease 2019 (COVID-19) has upended the world with over 6.6 million infections and over 391,000 deaths worldwide. Reverse-transcription polymerase chain reaction (RT-PCR) assay is the preferred method of diagnosis of COVID-19 infection. Yet, chest CT is often used in patients with known or suspected COVID-19 due to regional preferences, lack of availability of PCR assays, and false-negative PCR assays, as well as for monitoring of disease progression, complications, and treatment response. The International Atomic Energy Agency (IAEA) organized a webinar to discuss CT practice and protocol optimization from a radiation protection perspective on April 9, 2020, and surveyed participants from five continents. We review important aspects of CT in COVID-19 infection from the justification of its use to specific scan protocols for optimizing radiation dose and diagnostic information.Key Points⢠Chest CT provides useful information in patients with moderate to severe COVID-19 pneumonia.⢠When indicated, chest CT in most patients with COVID-19 pneumonia must be performed with non-contrast, low-dose protocol.⢠Although chest CT has high sensitivity for diagnosis of COVID-19 pneumonia, CT findings are non-specific and overlap with other viral infections including influenza and H1N1.
Assuntos
Betacoronavirus , Infecções por Coronavirus/diagnóstico , Pandemias , Pneumonia Viral/diagnóstico , Tomografia Computadorizada por Raios X/métodos , COVID-19 , Infecções por Coronavirus/epidemiologia , Progressão da Doença , Humanos , Pneumonia Viral/epidemiologia , Doses de Radiação , SARS-CoV-2RESUMO
PURPOSE: Safety in Radiation Oncology (SAFRON) is a reporting and learning system on radiotherapy and radionuclide therapy incidents and near misses. The primary aim of this paper is to examine whether any discernible patterns exist in the causes of reported incidents and safety barriers within the SAFRON system concerning external beam radiotherapy. METHODS AND MATERIALS: This study focuses on external beam radiotherapy incidents, reviewing 1685 reports since the inception of SAFRON until December 2021. Reports that did not identify causes of incidents and safety barriers were excluded from the final study population. RESULTS: Simple two-dimensional radiotherapy or electron beam therapy were represented by 97 reports, three-dimensional conformal radiotherapy by 39 reports, modulated arc therapy by 12 reports, intensity modulated radiation therapy by 11 reports, stereotactic radiosurgery by 4 reports, and radiotherapy with protons or other particles by 1 report, while for 92 of them, no information on treatment method had been provided. Most of the reported incidents were minor incidents and were discovered by the radiation therapist. Inadequate direction/information in staff communication was the most frequently reported cause of incident, and regular independent chart check was the most common safety barrier. CONCLUSIONS: The results indicate that the majority of incidents were reported by radiation therapists, and the majority of these incidents were classified as minor. Communication problems and failure to follow standards/procedures/practices were the most frequent causes of incidents. Furthermore, regular independent chart checking was the most frequently identified safety barrier.
Assuntos
Radioterapia (Especialidade) , Radiocirurgia , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Aprendizagem , Gestão de Riscos/métodosRESUMO
This review summarises the current knowledge about recurrent radiological imaging and associated cumulative doses to patients. The recent conservative estimates are for around 0.9 million patients globally who cumulate radiation doses above 100 mSv, where evidence exists for cancer risk elevation. Around one in five is estimated to be under the age of 50. Recurrent imaging is used for managing various health conditions and chronic diseases such as malignancies, trauma, end-stage kidney disease, cardiovascular diseases, Crohn's disease, urolithiasis, cystic pulmonary disease. More studies are needed from different parts of the world to understand the magnitude and appropriateness. The analysis identified areas of future work to improve radiation protection of individuals who are submitted to frequent imaging. These include access to dose saving imaging technologies; improved imaging strategies and appropriateness process; specific optimisation tailored to the clinical condition and patient habitus; wider utilisation of the automatic exposure monitoring systems with an integrated option for individual exposure tracking in standardised patient-specific risk metrics; improved training and communication. The integration of the clinical and exposure history data will support improved knowledge about radiation risks from low doses and individual radiosensitivity. The radiation protection framework will need to respond to the challenge of recurrent imaging and high individual doses. The radiation protection perspective complements the clinical perspective, and the risk to benefit analysis must account holistically for all incidental and long-term benefits and risks for patients, their clinical history and specific needs. This is a step toward the patient-centric health care.
Assuntos
Diagnóstico por Imagem , Neoplasias Induzidas por Radiação/epidemiologia , Neoplasias Induzidas por Radiação/prevenção & controle , Doses de Radiação , Proteção Radiológica/métodos , Humanos , Monitoramento de Radiação/métodos , Radiação Ionizante , Compostos Radiofarmacêuticos , Retratamento , Fatores de RiscoRESUMO
BACKGROUND: Patient immobilisation and position are important contributors to the reproducibility and accuracy of radiation therapy. In addition the choice of position can alter the external contour of the treated area and has the potential to alter the spatial relationship between internal organs. The published literature demonstrates variation in the use of the prone and supine position for prostate cancer radiation therapy. Previous investigators using different protocols for patient preparation, imaging and target volume definition have demonstrated changes in the calculated therapeutic ratio comparing the two positions. We did not use rigid immobilisation, laxatives, rectal catheters or bladder voiding and assessed if in the prone position would cause a reduction of the dose to the rectum. We performed a prospective comparison of the two positions in 26 patients to determine if the differences in the spatial relation between the rectum and the planning target volume (PTV) would impact on dose-volume histograms to organs at risk (OAR). We also determined if any such improvement might permit dose escalation. MATERIALS AND METHODS: Twenty-six patients with clinically localized prostate cancer consented to participate in this study. All patients underwent a planning CT scan in both the prone and supine treatment positions. The PTV and OAR were drawn on each set of scans by one of the investigators. The PTV included the prostate and seminal vesicles with a 1cm margin except posteriorly where this margin was reduced to 5mm. The outer circumference of the bladder, rectal wall, small bowel (when present) was drawn along with femoral heads. 3D conformal treatment plans were computed using Helax TMS version 6.1B. A 3-field treatment technique was employed with energy of 10/15 MV. The prescribed dose was 70 Gy and the PTV was encompassed by the 95% isodose and the maximum dose was always less than 107%. Cumulative dose-volume histograms were calculated for the PTV, rectum, bladder, femoral heads and small bowel (when present). These non-uniform histograms for both the prone and supine treatment positions were transformed into uniform ones using the effective volume method [Kutcher J, Burman C. Calculation of probability factors for non-uniform normal tissue irradiation: the effective volume method. Med Phys 1987;14:487]. RESULTS: Twenty-one of the 26 (80%) patients had a lower effective volume of rectum irradiated if the prone instead of the supine treatment position was used. The median value of the effective volume in the supine treatment position was 31.74 Gy while the median value in the prone position was 22.48 Gy. The dose escalation was applied to the patients in the prone treatment position until the effective volume for the rectum was the same as that in the supine position. The range of dose escalation possible for these patients was 0.1-7.9 Gy. These patients could potentially have the dose escalated from the prescribed dose of 70 Gy for the supine position without any increase in side effects. For the five patients where no potential benefit was found when changing treatment position, only two patients displayed a significant (>1 Gy) advantage for the supine treatment position. Twenty-one of the 26 patients also showed an advantage for the prone treatment position in relation to bladder dose. CONCLUSION: The use of the prone position reduced the dose to the unprepared rectum and unvoided bladder in the majority of cases. It should be considered particularly in cases where large posterior seminal vesicles cause significant overlap between the planning target volume and the rectum.
Assuntos
Decúbito Ventral/fisiologia , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reto/efeitos da radiação , Resultado do TratamentoRESUMO
Inappropriate imaging can lead to unnecessary medical radiologic exposures and cost and may not answer the clinical question. Imaging referral guidelines inform the justification of radiologic procedures and facilitate the choice of the best test first, but their acceptance by referrers, use, and value may be limited by shortcomings in the methodology of development. Focusing on common, essential elements of methodology will help guideline developers. In 2012 and 2013, the International Atomic Energy Agency hosted Technical Meetings on Radiation Protection of Patients Through the Development of Appropriateness Criteria in Diagnostic Imaging. Participants identified and agreed on issues concerning development of imaging referral guidelines. Items based on the Appraisal of Guidelines for Research and Evaluation II instrument were amended with additional items including development and consensus group composition. Consensus was sought on 28 items, 18 of which were agreed should be uniform, and 10 should allow for regional differences. Further work is required to encourage, provide, and identify higher quality evidence and to agree on a grading system for recommendations. Many key areas are common to guideline developers globally, opening the way for international collaboration to help demystify, simplify, and justify.
Assuntos
Diagnóstico por Imagem/normas , Cooperação Internacional , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/normas , Proteção Radiológica/normas , Radiologia/normas , Humanos , Estados UnidosRESUMO
It is known that the use of imaging in clinical situations is not always optimal, leading to suboptimal health care and potential radiation risk. There may be overuse of imaging, underuse, or use of the wrong modality. The use of clinical imaging guidelines is likely to improve the use of imaging, but roadblocks exist. Some of these relate to regulatory oversight and mandates. There is wide variation by country and region in the regulatory setting, ranging from actual absence of regulatory authorities to mandated availability of clinical imaging guidelines in the European Community. Collaborative efforts to ensure that clinical imaging guidelines are at least available is a good starting point. Regulatory oversight and support are necessary to ensure the use of clinical imaging guidelines. Regulations should address 3 areas: availability, clinical utilization, and adherence to and revision of guidelines. The use of both internal and external audits, with the aim of both use of and adherence to guidelines and quality improvement, is the best tool for enhancing use. The major challenges that need to be addressed, collaboratively, to ensure the dissemination and use of clinical imaging guidelines are the development of regulations, of regulatory structures that can be effectively deployed, and of benchmarks for adherence and for utility.
Assuntos
Diagnóstico por Imagem/normas , Guias de Prática Clínica como Assunto , Garantia da Qualidade dos Cuidados de Saúde/legislação & jurisprudência , Garantia da Qualidade dos Cuidados de Saúde/normas , Radiologia/legislação & jurisprudência , Radiologia/normas , Auditoria Clínica/legislação & jurisprudência , Auditoria Clínica/normas , Europa (Continente) , Regulamentação Governamental , Fidelidade a Diretrizes/legislação & jurisprudência , Fidelidade a Diretrizes/normas , Estados UnidosRESUMO
A recent international meeting was convened by two United Nations bodies to focus on international collaboration on clinical appropriateness/referral guidelines for use in medical imaging. This paper, the second of 4 from this technical meeting, addresses barriers to the successful development/deployment of clinical imaging guidelines and means of overcoming them. It reflects the discussions of the attendees, and the issues identified are treated under 7 headings: â Practical Strategy for Development and Deployment of Guidelines; â Governance Arrangements and Concerns with Deployment of Guidelines; â Finance, Sustainability, Reimbursement, and Related Issues; â Identifying Benefits and Radiation Risks from Radiological Examinations; â Information Given to Patients and the Public, and Consent Issues; â Special Concerns Related to Pregnancy; and â The Research Agenda. Examples of topics identified include the observation that guideline development is a global task and there is no case for continuing it as the project of the few professional organizations that have been brave enough to make the long-term commitment required. Advocacy for guidelines should include the expectations that they will facilitate: (1) better health care delivery; (2) lower cost of that delivery; with (3) reduced radiation dose and associated health risks. Radiation protection issues should not be isolated; rather, they should be integrated with the overall health care picture. The type of dose/radiation risk information to be provided with guidelines should include the uncertainty involved and advice on application of the precautionary principle with patients. This principle may be taken as an extension of the well-established medical principle of "first do no harm."
Assuntos
Diagnóstico por Imagem/normas , Consentimento Livre e Esclarecido/normas , Guias de Prática Clínica como Assunto , Proteção Radiológica/normas , Radiologia/normas , Humanos , InternacionalidadeRESUMO
The effective development and use of clinical imaging guidelines requires an understanding of who the stakeholders are, what their interests in the process are, and what roles they should play. If the appropriate stakeholders are not engaged in the right roles, it is unlikely that clinical imaging guidelines will be successfully developed, relied on, and actually used. Some stakeholders are obvious: for the development of clinical imaging guidelines, both imagers and those who request examinations, such as general practitioners, internists, and medical specialists, must be involved. To gain acceptance, other relevant groups are stakeholders, including medical societies, other health care professionals, insurers, health IT experts and vendors, and patients. The role of stakeholders must be dictated by their specific interest. For some, involvement in the creation of guidelines is the right role. For others, such as regulators or insurers, reviews or invitations to comment are required, and for others, such as medical educators, it is probably sufficient to provide information and create awareness. Only through a careful consideration of who the stakeholders are and what are their interests are the successful development, acceptance, and use of clinical imaging guidelines likely to occur. Future efforts must focus on collaboration, particularly among groups that create clinical imaging guidelines and those that can support their use, and on regulatory roles and mandates.
Assuntos
Comportamento Cooperativo , Tomada de Decisões , Modelos Organizacionais , Objetivos Organizacionais , Guias de Prática Clínica como Assunto , Radiologia/organização & administração , Medicina Baseada em Evidências , Estados UnidosRESUMO
BACKGROUND AND PURPOSE: Appropriate planning target volume (PTV) definition is critical for local disease eradication in the treatment of non-small cell lung cancer (NSCLC). When margins are added to the gross tumour volume (GTV) in the standard way, the PTV formed may be too large to facilitate dose escalation due to normal tissue tolerance. To increase the feasibility of dose escalation with 3-dimensional conformal radiotherapy (3DCRT), this study examines an alternative method for the formation of the PTV in NSCLC. This strategy is based on the reduced probability of tumour cells from the GTV outwards and on the associated lower dose requirements to eradicate such subclinical disease. MATERIALS AND METHODS: 3DCRT plans were generated from the CT scans of 15 patients with NSCLC (stages Ib to IIIb). Each PTV was formed by adding a margin for geometric uncertainties directly onto the GTV. The success of this approach is dependent on the volume immediately outside this smaller PTV, the Rind volume, receiving 50 Gy, the minimum dose requirement that is considered sufficient for eradication of the reduced tumour cell density in this volume. While optimizing the treatment plans for each PTV to 70 Gy, the dose distribution in the Rind volume, and the factors affecting it, were assessed. RESULTS: One hundred percent of each PTV received a minimum of 95% of the prescribed dose. The percentage of the Rind volume receiving 50 Gy or more (V50) had a median value of 94%. The minimum dose in this volume, however, ranged from 5.6 to 32.1 Gy. The V50 was highest for apical tumours (96.1%) and lowest for peripheral tumours (86%) and correlated positively with the size of the PTV (Kendall's rank correlation (Kt)=+0.3, P=0.05) and the number of beams used (Kt=+0.3, P=0.03) but not with the conformity index. The average volume outside the Rind which still received >/=50 Gy (the Wasted 50 Gy) increased significantly with the V50 of the Rind volume and was inversely proportional to the Rind <50 Gy, correlating significantly with the dose to the organs at risk. CONCLUSIONS: Using this strategy with standard 3DCRT, all PTVs were irradiated to the required dose with this approach, but none of the corresponding Rind volumes had an acceptable dose distribution. The addition of dual volume planning or the use of intensity modulated radiation therapy may achieve an appropriate dose distribution in the Rind volume while not increasing the dose to the organs at risk and may thereby facilitate dose escalation.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Dose Máxima Tolerável , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Probabilidade , Estudos Prospectivos , Doses de Radiação , Lesões por Radiação/prevenção & controle , Medição de Risco , Estudos de Amostragem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios XRESUMO
BACKGROUND AND PURPOSE: To prospectively assess the feasibility and efficacy of a hypofractionated accelerated radiotherapy regimen (72 Gy in 24 daily fractions, 3 Gy per fraction) in patients (pts) with non-resectable non-small-cell lung cancer (NSCLC). MATERIAL AND METHODS: We included 25 pts with a histologically or cytologically proven NSCLC, with KPS > or = 70 and < or =10% weight loss over prior three months, and with tumour stage I/II medically inoperable (9 pts) or non-resectable stage III a/b without pleural effusion (16 pts). Eleven pts received induction chemotherapy. No more than 30% of the combined lung volume could receive more than 25 Gy and the maximal biological effective dose to the spinal cord was maintained below 44 Gy. RESULTS: No grade-4 acute toxicity event was reported. Two pts had a treatment break because of grade-3 acute oesophagitis. Twenty-two pts were evaluable for long-term toxicity (median follow-up=9.7 months, range 4 to 30.2 months). There were 4 Grade-1 pulmonary and 2 Grade-1 oesophageal long-term toxicity events. Twenty-two pts were evaluable for tumour response with 7 complete and 8 partial responses, 5 stable diseases and 2 progressive diseases. The actuarial 1-year overall and thoracic-progression-free survival rates were 68% and 72% respectively. CONCLUSIONS: This study demonstrates the feasibility of the experimental radiotherapy schedule, however more data are needed to confirm its efficacy.