Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 30(2): 527-535, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32839848

RESUMO

PURPOSE: The aim of this study was to assess the mid-term clinical outcome of the ankle joint after total knee arthroplasty (TKA) in high-grade valgus osteoarthritis. METHODS: In this case-control study, n = 36 patients with a preoperative mechanical tibiofemoral angle (mTFA) ≥ 15° who underwent TKA between December 2002 and December 2012 were included. The control group (mTFA < 15°) of n = 60 patients was created using case matching. Radiological [mechanical tibiofemoral angle (mTFA) and ankle joint orientation to the ground (G-AJLO)] and clinical parameters [Foot Function Index (FFI), Knee Society Score, Forgotten Joint Score, and Range of Motion (ROM)] were analysed. The mean follow-up time was 59 months (IQR [56, 62]). RESULTS: The degree of correcting the mTFA by TKA significantly correlated with the postoperative FFI (R = 0.95, p < 0.05), although the knee and ankle joint lines were corrected to neutral orientations. A cut-off value of 16.5° [AUC 0.912 (0.85-0.975 95% CI), sensitivity = 0.8, specificity = 0.895] was calculated, above which the odds ratio (OR) for developing ankle symptoms increased vastly [OR 34.0 (9.10-127.02 95% CI)]. ROM restrictions of the subtalar joint displayed a strong significant correlation with the FFI (R = 0.74, p < 0.05), demonstrating that decreased ROM of the subtalar joint was associated with aggravated outcomes of the ankle joint. CONCLUSIONS: In this study, higher degrees of leg axis correction in TKA were associated with increased postoperative ankle symptoms. When TKA is performed in excessive valgus knee osteoarthritis, surgeons should be aware that this might trigger the onset or progression of ankle symptoms, particularly in cases of a stiff subtalar joint. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Tornozelo/cirurgia , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Artroplastia do Joelho/efeitos adversos , Estudos de Casos e Controles , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Estudos Retrospectivos
2.
Knee Surg Sports Traumatol Arthrosc ; 30(9): 3155-3161, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33881572

RESUMO

PURPOSE: Standardized outcome measures are crucial for the evaluation of different treatment and rehabilitation regimes in patients after total knee arthroplasty (TKA). Performance-based measures are necessary to capture different aspects of physical function. High reliability and agreement of five performance-based measures were hypothesized to differentiate between measurement error and change in test performance. Secondary outcomes are the correlation of performance-based measurements to KSS and WOMAC prior to surgery (baseline) and 10 weeks thereafter (t3). METHODS: The test-retest reliabilities and agreements of the 1-m walk test, the stair-climbing test, the timed-up-and-go test, the weight-balanced-chair-rising test and the isometric maximum knee extension force in patients undergoing total knee replacements were studied. The intraclass correlation coefficient was calculated and a Bland-Altman analysis performed. RESULTS: The weight-balanced-chair-rising test showed a symmetry at baseline = 0.77, 5 ± 1 days after surgery (t1) = 0.50, 9 ± 1 days (t2) = 0.59 and (t3) = 0.80. All performance tests showed high intraclass correlation coefficients (ICC = 0.81-0.99). The 10-m walk test, stair climbing test, and the timed-up-and-go test showed high agreement in the Bland-Altman analysis. The Bland-Altman analysis for the weight-balanced-chair-rising test and isometric knee extension force indicated high agreement at 5 and 9 days postoperatively, but the relative measurement error increased pre- and 10 weeks postoperatively. CONCLUSION: In conclusion, symmetry, as an important outcome after TKA, is a reliable and rather unique item that should unquestionably be added to established measurements like walking tests or survey-based function assessment. The implementation of standardized performance-based measures to assess physical function in rehabilitation procedures will help to improve the more objectively based assessment of different rehabilitation protocols. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho , Equilíbrio Postural , Reprodutibilidade dos Testes , Estudos de Tempo e Movimento
3.
Knee Surg Sports Traumatol Arthrosc ; 29(11): 3641-3647, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33165633

RESUMO

PURPOSE: Released particles are a major risk of airborne contamination during surgery. The present prospective study investigated the quantitative and qualitative particle load in the operating room (OR) depending on location, time of surgery and use of laminar air flow (LAF) system. METHODS: The particle load/m3 was measured during the implantation of 12 total knee arthroplasties (6 × LAF, 6 × Non-LAF) by using the Met One HHPC 6 + device (Beckmann Coulter GmbH, Germany). Measurement was based on the absorption and scattering of (laser) light by particles and was performed at three different time-points [empty OR, setting up, ongoing operation) at 3 fixed measurement points [OR table (central LAF area), anaesthesia tower (marginal LAF area), surgical image amplifier (outside LAF area)]. RESULTS: Independent of time and location, all measurements showed a significantly higher particle load in the Non-LAF group (p < 0.01). With ongoing surgical procedure both groups showed increasing particle load. While there was a major increase of fine particles (size < 1 µm) with advancing activity in the LAF group, the Non-LAF group showed higher particle gain with increasing particle size. The lowest particle load in the LAF group was measured at the operating column, increasing with greater distance from the operating table. The Non-LAF group presented a significantly higher particle load than the LAF group at all locations. CONCLUSION: The use of a LAF system significantly reduces the particle load and therefore potential bacterial contamination regardless of the time or place of measurement and therefore seems to be a useful tool for infection prevention. As LAF leads to a significant decrease of respirable particles, it appears to be a protective factor for the health of the surgical team regardless of its use in infection prevention. LEVEL OF EVIDENCE: I.


Assuntos
Artroplastia do Joelho , Ventilação , Microbiologia do Ar , Estudos de Coortes , Humanos , Salas Cirúrgicas , Estudos Prospectivos , Infecção da Ferida Cirúrgica
4.
Orthopade ; 49(7): 562-569, 2020 Jul.
Artigo em Alemão | MEDLINE | ID: mdl-32494903

RESUMO

INTRODUCTION: Mechanical alignment (MA) is a standardized procedure that aims to achieve a neutrally aligned leg axis. An alignment of the prosthesis closer to the patient's anatomy can be an approach for better clinical outcomes. The surgical technique of adjusted mechanical alignment (aMA) presented here is a modified extension-gap-first technique that takes into account the natural ligamentous tension of the knee joint so that ligamentous releases can be avoided as far as possible. INDICATION: The aMA technique can be used for primary and secondary varus gonarthrosis of up to 20° of varus. SURGICAL TECHNIQUE: The aim of the operation is to achieve a balanced ligament tension through a femoral osseous correction rather than ligament releases. TEA and the sulcus line are marked to control the ligament-based femoral rotation. The osteophytes are removed to ensure a reliable ligament tension. A quantitative ligament tensioner is stretched with great care, and gap width as well as medial and lateral ligament tension are read off. In order to correct an extension gap asymmetry, instead of the typical medial soft tissue release, the asymmetry is compensated by a special femoral cutting block. Now, the flexion gap is assessed, whereby the transverse femoral rotation follows the soft tissue tension. The tensioner adjusts a rectangular flexion gap with balanced ligament tension. After a final balancing of the gaps, the femoral preparation is completed and the trial components are inserted. Here, the rotation of the tibial component is set by repeated flexion-extension cycles. DISCUSSION AND CONCLUSION: The technique presented combines a measured-resection technique with individual ligament tension. The maximum deviation of the femoral alignment in the coronal plane from the neutral alignment is 2.5°. In order to avoid problems, it is recommended, as with the described technique, to achieve a component alignment based on the patient anatomy by adjusting the femoral component. The measured-resection technique carries the risk of flexion instability. With the gap-balancing technique symmetrical ligament tension can be achieved, assuming precise proximal tibial cuts. When aligning the femoral component rotation, flexion gap stability and patella tracking should be considered. Long-term studies of high case numbers are necessary to evaluate the good short-term results of the presented surgical technique.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/cirurgia , Prótese do Joelho , Fêmur , Humanos , Amplitude de Movimento Articular , Tíbia
5.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1456-1462, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29767270

RESUMO

PURPOSE: It was hypothesized that malrotation of femoral component in total knee arthroplasty (TKA) will significantly impact clinical outcome. METHODS: Eighty-eight consecutive patients with primary osteoarthritis of the knee were prospectively evaluated. They received a cemented posterior stabilized TKA (NexGen, Zimmer/Biomet® Inc., Warsaw, IN, USA). The femoral component was placed in 3° of external rotation referenced to the posterior condylar line. Postoperatively, a CT scan was performed to evaluate rotation of femoral component in the transverse plane. SF-36, KSS, and WOMAC, as well as their range of motion was assessed prior to surgery, after 6 and 24 months. Data are presented as mean and standard deviation (SD), as well as range if applicable. Correlation analysis was performed between the placement of the femoral component in the transverse plane and the clinical outcome. RESULTS: Femoral component placement was on average 0.1° [SD 2.5°, range - 6.5° to + 6.5°] referenced to the surgical transepicondylar line showing a wide range between the two landmarks after surgery. After 6 months, WOMAC category 'physical function' correlated significantly with femoral component rotation (r = - 0.28, p = 0.007). After 24 months, WOMAC categories 'physical function' and 'pain' correlated significantly with femoral rotation (r = - 0.41, p < 0.001; and r = - 0.33, p = 0.001). No significant correlations were found between femoral component rotation and range of motion (r = 0.04), WOMAC category "stiffness", KSS, as well as SF-36 questionnaires. These reported formally significant correlations were without any clinical relevance. DISCUSSION: The study showed that there is a significant patients specific femoral component placement in the transverse plane. Internal or external malrotation of the femoral component does not correlate automatically with poor knee function. The lack of correlation between femoral component position and clinical as well as functional outcome underlines complexity and significant individuality of each patient. The surgeon should be aware of the finding and attention should be paid during surgery when significant divergency is seen between the two landmarks. Soft tissue balancing might be very crucial in these specific patients, which needs to be studied in depth in the future. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia do Joelho , Fêmur/cirurgia , Articulação do Joelho/cirurgia , Idoso , Feminino , Fêmur/anatomia & histologia , Humanos , Joelho/anatomia & histologia , Joelho/fisiologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos , Amplitude de Movimento Articular , Rotação , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
6.
Knee Surg Sports Traumatol Arthrosc ; 27(5): 1470-1476, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29992465

RESUMO

PURPOSE: The mechanical axis of the lower limb has shown to vary between different weight-bearing conditions and change after total knee arthroplasty (TKA). The purpose of this study was to investigate the correlation between mechanical axis alignment in standing long-leg radiographs and limb loading after TKA. METHODS: Mechanical axis of the lower limb and limb loading have been prospectively evaluated in 115 patients 10 days and 3 months after TKA. By the moment of standing long-leg radiography for analysis of the mechanical leg axis, two digital scales separately captured the load of each limb. RESULTS: Mechanical axis changed from an initial - 1° ± 2° valgus alignment to a varus axis of + 1° ± 2° (p < 0.01). This change in alignment was associated with an increase of limb loading from 89.9 ± 10.7 to 93.0 ± 7.0% (p < 0.01). The mechanical axis strongly correlated with relative limb loading at the first and second measurements (r = 0.804, p < 0.001, respectively, r = 0.562, p < 0.001). A significant change in the rate of outliers was registered within the observation period. These alterations and distinctions were much more pronounced in patients with postoperative incomplete extension (n = 15). CONCLUSIONS: The postoperative mechanical axis correlates with limb loading. A clinical relevant change in frontal alignment of the lower limb is associated with increased limb loading after TKA. The actual mechanical axis can only be assessed at physiological limb loading in long-leg radiographs with complete extension at full weight bearing. LEVEL OF EVIDENCE: Diagnostic study, Level II.


Assuntos
Articulação do Joelho/diagnóstico por imagem , Perna (Membro)/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Feminino , Humanos , Articulação do Joelho/cirurgia , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento , Osteoartrite do Joelho/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Radiografia , Estresse Mecânico , Suporte de Carga
7.
Arch Orthop Trauma Surg ; 139(10): 1455-1460, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31414170

RESUMO

BACKGROUND: Anteroposterior (AP) whole leg radiographs (WLR) in the standing position for assessment of the mechanical leg axis are generally performed preoperatively for the planning of total knee replacement (TKR) and postoperatively to assess the leg axis. The objective of the present study was to investigate whether, if preoperative WLR are available, postoperative AP standard knee radiographs in the standing position are sufficient for calculating the mechanical leg axis. METHODS: In the present prospective study, the mechanical and the anatomical leg axes were determined on the basis of WLR from 104 patients prior to implantation of a TKR and the difference was calculated. Twelve weeks postoperatively, standing long AP radiographs and WLR were prepared. In addition, the mechanical axis was calculated by adding the preoperative difference between the anatomical and mechanical axis to the anatomical axis from the postoperative AP radiographs. Accuracy, bias and level of agreement for calculated relative to measured mechanical alignment were determined. RESULTS: Mean accuracy of calculated mechanical alignment was 0.5° ± 0.4°, and mean bias was 0.0° ± 0.6° (p = 1.00). Bland-Altman analysis revealed a 95% upper and lower level of agreement of - 1.3° and 1.3°, respectively. CONCLUSION: A preoperative WLR and a postoperative long AP knee standard radiograph are sufficient to determine the mechanical leg axis after TKR. If these are available, it is possible to do without WLR after TKR, particularly since they involve higher radiation exposure, are time-consuming, and are also prone to errors in the first postoperative weeks. LEVEL OF EVIDENCE: II diagnostic study.


Assuntos
Artroplastia do Joelho , Articulação do Joelho/diagnóstico por imagem , Ossos da Perna/diagnóstico por imagem , Radiografia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Prospectivos
8.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2788-2796, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29071356

RESUMO

PURPOSE AND HYPOTHESIS: Patient-specific instrumentation (PSI) uses 3D preoperative imaging to produce individualized cutting blocks specific to patients' anatomy and according to the preoperative plan with the aim to reduce the number of mechanical leg alignment (MLA) outliers, to improve implant positioning and to decrease surgery time. The primary purpose of this study was to investigate the efficacy of a specific PSI in comparison with standard instrumentation (SI) in reducing the number of MLA outliers. It was hypothesized that the number of MLA outliers would be significantly lower in the PSI group. METHODS: A multicenter randomized controlled trial was implemented. There were 59 patients in the PSI group and 66 in the SI group. The absolute number of outliers outside the ± 3° target neutral MLA was compared between the groups with a Chi-square test. As secondary outcomes, the Knee Society Score (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were compared between the groups preoperatively and at 90-day follow-up. RESULTS: There were 15 (26.3%) MLA outliers in the PSI group and 8 (12.3%) in the SI group. The number of outliers was not independent from the group ( X2 (1) = 3.8, p = 0.04; Relative risk = 1.5). Preoperatively, there were no significant differences between the groups when comparing their KSS and KOOS sub-scores. At 90 days postoperatively, the patients in the SI group showed better KOOS-Quality of Life (KOSS-QOL) in comparison with the PSI group (p < 0.0001). CONCLUSION: The use of PSI did not significantly reduce the number of MLA outliers in comparison with SI. There were no differences when comparing the achieved mean MLA of both groups. LEVEL OF EVIDENCE: Level I, prospective randomized controlled trial.


Assuntos
Artroplastia do Joelho/métodos , Imageamento Tridimensional , Joelho/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Feminino , Humanos , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Período Pós-Operatório , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento
9.
Eur J Orthop Surg Traumatol ; 27(5): 683-688, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27714451

RESUMO

While patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) allows for transfer of the preoperative plan onto bony landmarks, the soft tissue balancing is not affected. The goals of this randomized clinical trial were to compare PSI and the measured resection technique (conventional) with PSI and the gap balancing technique. Fifty patients were randomized to TKA with conventional PSI (PSI-S) (n = 25) or to PSI with additional gap balancing (PSI-GB) (n = 25). All patients were clinically examined at 3 and 12 months postoperatively. Data on the range of motion, the Knee Society Score, the Western Ontario and McMasters Universities Osteoarthritis Index, the High-Flexion Knee Score (HFKS), and the Forgotten Joint Score (FJS) were compiled at follow-up. Statistically significant improvements were found for all clinical parameters in the PSI-GB group compared to the PSI-S group at 3 months postoperatively and for FS, FJS, and HFKS at 12 months. However, the relevance of these differences, as well as their effect on long-term outcomes, needs to be evaluated further. In conclusion, patient-specific instrumentation combined with gap balancing yielded good early clinical outcomes.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Idoso , Artroplastia do Joelho/instrumentação , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Fatores de Tempo
10.
J Arthroplasty ; 31(8): 1803-7, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26923499

RESUMO

BACKGROUND: Standing long-leg radiographs allow assessment of the mechanical axis in the frontal plane before and after total knee arthroplasty (TKA). An alteration in loading, and hence in the forces acting on the knee joint, occurs postoperatively. We therefore postulated that the mechanical axis measured in the long-leg standing radiograph would change within the first year after TKA. METHODS: Standing long-leg radiographs of 156 patients were performed 7 days, 3 months, and 12 months after TKA with determination of mechanical axis of the lower limb. RESULTS: Seven days after surgery, the mechanical axis amounted 0.8° ± 1.7° valgus. Three months after the operation, at 1.3° ± 1.3° varus, it was significantly different (P < .001) from the primary measurement. No further alteration in the mechanical axis occurred during the first year after TKA. This difference was even more pronounced (P < .001) in patients with a postoperative lack of complete extension. Seven days after surgery, they had a valgus axis deviation of 1.6° ± 1.6°; after 3 months, the measurement amounted 1.2° ± 1.3° varus. CONCLUSION: Measured by a standing long-leg radiograph, the frontal mechanical axis after TKA changes over time. The predictive power of a standing long-leg radiograph in the first week after surgery is limited because limb loading is altered because of pain and is therefore nonphysiological. The actual mechanical axis resulting after TKA can only be assessed in a standing long-leg radiograph at physiological loading.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Extremidade Inferior/cirurgia , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Articulação do Joelho/diagnóstico por imagem , Extremidade Inferior/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Período Pós-Operatório , Postura , Radiografia , Estresse Mecânico , Fatores de Tempo
11.
Arch Orthop Trauma Surg ; 136(7): 991-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27271756

RESUMO

PURPOSE: Individual implant alignment in total knee arthroplasty (TKA) has seen growing interest over the past years. This study therefore aimed to develop a surgical technique for implant alignment based on native ligament tension, and to present the results obtained using this technique. METHODS: 25 patients were included in this prospective study. Patient-specific instrumentation (PSI) was used for the resection of the extension gap. Ligament tension was measured after the removal of all accessible osteophytes. In the event of asymmetry, the distal femur resection was adjusted up to 2.5° using an adjustable cutting block. The aim was to achieve a symmetrical extension gap without release, not a neutral leg axis. Femoral rotation was aligned on the basis of ligament tension. Patients were followed up to 3 months postoperatively. RESULTS: The postoperative whole-leg axis was 2.8° ± 1.6° varus. Patients achieved a flexion of 118° ± 9°, a Knee Score of 91.5 ± 3.2 and a Function Score of 86.8 ± 8.3 points. CONCLUSION: For the first time, the new surgical technique described here permits a ligament tension based femoral implant alignment together with PSI. It was shown to be safe, with encouraging clinical and radiological results. LEVEL OF EVIDENCE: Therapeutic study level IV.


Assuntos
Artroplastia do Joelho/métodos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Idoso , Feminino , Fêmur/cirurgia , Humanos , Prótese Articular , Ligamentos Articulares/cirurgia , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Período Pós-Operatório , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia
12.
J Arthroplasty ; 30(4): 564-6, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25486944

RESUMO

UNLABELLED: The purpose of this study was to determine if intraoperative navigation predicted final implant position of total knee arthroplasties (TKAs) performed with patient-specific instrumentation (PSI). We retrospectively reviewed 60 TKAs performed with PSI and imageless navigation. These values were compared to postoperative coronal alignment based on long-leg radiographs, as well as rotation and tibial slope based on CT scans. The intraoperative coronal position of the tibia as measured by the intraoperative navigation indicated a significantly higher deviation from the neutral mechanical axis than the actual final position (P=0.03). Similarly, tibial slope and femoral component rotation measured by intraoperative navigation significantly deviated from the final slope and femoral component rotation (P<0.0001). In conclusion, intraoperative navigation of PSI position showed a significantly high deviation from the true final implant position. LEVEL OF EVIDENCE: Level III, therapeutic. See Instructions to Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Prótese do Joelho , Cirurgia Assistida por Computador/instrumentação , Idoso , Feminino , Fêmur/cirurgia , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Rotação , Tíbia/cirurgia , Tomografia Computadorizada por Raios X
13.
Arch Orthop Trauma Surg ; 135(11): 1603-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26315332

RESUMO

INTRODUCTION: Combining patient-specific instrumentation (PSI) with a balancer device in total knee arthroplasty (TKA) to achieve functional femoral rotational alignment is a novel technique. The primary goal of this study was to introduce a new method to combine PSI with a gap-balancing technique and to determine the impact of the technique on rotation of the femoral component. MATERIALS AND METHODS: Twenty-five primary TKAs (15 women, 10 men) were prospectively studied. All TKAs involved PSI with an associated gap-balancing device. Front plane alignment was performed intraoperatively with the PSI, followed by rectangular, symmetrical extension and creation of a flexion gap using the balancer device to set the femoral rotation. RESULTS: Femoral component rotation was between 3° internal and 6° external rotation versus the transepicondylar axis. There were no postoperative signs of patellofemoral dysfunction. In no cases was the resulting joint line displacement >3 mm. The mean elevation was 1.2 ± 0.9 mm (range 0-3). The leg axis was straight in all cases (±3°), at a mean of 1.6° ± 1.0° varus (range 0°-3° varus). CONCLUSIONS: PSI was with the gap-balancing technique was successfully used without affecting anatomical alignment. With the balancer device, PSI can be used more widely than techniques based solely on landmarks, as the soft-tissue tension can be taken into account, thus virtually eliminating flexion instabilities.


Assuntos
Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Amplitude de Movimento Articular/fisiologia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos
14.
Clin Orthop Relat Res ; 472(10): 2913-22, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25024031

RESUMO

BACKGROUND: Patient-specific instrumentation in TKA has the proposed benefits of improving coronal and sagittal alignment and rotation of the components. In contrast, the literature is inconsistent if the use of patient-specific instrumentation improves alignment in comparison to conventional instrumentation. Depending on the manufacturer, patient-specific instrumentation is based on either MRI or CT scans. However, it is unknown whether one patient-specific instrumentation approach is more accurate than the other and if there is a potential benefit in terms of reduction of duration of surgery. QUESTIONS/PURPOSES: We compared the accuracy of MRI- and CT-based patient-specific instrumentation with conventional instrumentation and with each other in TKAs. The three approaches also were compared with respect to validated outcomes scores and duration of surgery. METHODS: A randomized clinical trial was conducted in which 90 patients were enrolled and divided into three groups: CT-based, MRI-based patient-specific instrumentation, and conventional instrumentation. The groups were not different regarding age, male/female sex distribution, and BMI. In all groups, coronal and sagittal alignments were measured on postoperative standing long-leg and lateral radiographs. Component rotation was measured on CT scans. Clinical outcomes (Knee Society and WOMAC scores) were evaluated preoperatively and at a mean of 3 months postoperatively and the duration of surgery was analyzed for each patient. MRI- and CT-based patient-specific instrumentation groups were first compared with conventional instrumentation, the patient-specific instrumentation groups were compared with each other, and all three approaches were compared for clinical outcome measures and duration of surgery. RESULTS: Compared with conventional instrumentation MRI- and CT-based patient-specific instrumentation showed higher accuracy regarding the coronal limb axis (MRI versus conventional, 1.0° [range, 0°-4°] versus 4.5° [range, 0°-8°], p < 0.001; CT versus conventional, 3.0° [range, 0°-5°] versus 4.5° [range, 0°-8°], p = 0.02), femoral rotation (MRI versus conventional, 1.0° [range, 0°-2°] versus 4.0° [range, 1°-7°], p < 0.001; CT versus conventional, 1.0° [range, 0°-2°] versus 4.0° [range, 1°-7°], p < 0.001), and tibial slope (MRI versus conventional, 1.0° [range, 0°-2°] versus 3.5° [range, 1°-7°], p < 0.001; CT versus conventional, 1.0° [range, 0°-2°] versus 3.5° [range, 1°-7°], p < 0.001), but the differences were small. Furthermore, MRI-based patient-specific instrumentation showed a smaller deviation in the postoperative coronal mechanical limb axis compared with CT-based patient-specific instrumentation (MRI versus CT, 1.0° [range, 0°-4°] versus 3.0° [range, 0°-5°], p = 0.03), while there was no difference in femoral rotation or tibial slope. Although there was a significant reduction of the duration of surgery in both patient-specific instrumentation groups in comparison to conventional instrumentation (MRI versus conventional, 58 minutes [range, 53-67 minutes] versus 76 minutes [range, 57-83 minutes], p < 0.001; CT versus conventional, 63 minutes [range, 59-69 minutes] versus 76 minutes [range, 57-83 minutes], p < .001), there were no differences in the postoperative Knee Society pain and function and WOMAC scores among the groups. CONCLUSIONS: Although this study supports that patient-specific instrumentation increased accuracy compared with conventional instrumentation and that MRI-based patient-specific instrumentation is more accurate compared with CT-based patient-specific instrumentation regarding coronal mechanical limb axis, differences are only subtle and of questionable clinical relevance. Because there are no differences in the long-term clinical outcome or survivorship yet available, the widespread use of this technique cannot be recommended.


Assuntos
Artroplastia do Joelho/instrumentação , Articulação do Joelho/cirurgia , Prótese do Joelho , Imageamento por Ressonância Magnética , Osteoartrite do Joelho/cirurgia , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X , Idoso , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/estatística & dados numéricos , Fenômenos Biomecânicos , Desenho Assistido por Computador , Difusão de Inovações , Feminino , Alemanha , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/patologia , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Osteoartrite do Joelho/diagnóstico , Osteoartrite do Joelho/fisiopatologia , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/estatística & dados numéricos , Fatores de Tempo , Resultado do Tratamento
15.
J Pers Med ; 13(7)2023 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-37511659

RESUMO

Due to the high heterogeneity in outcome measures after total hip arthroplasty (THA), the prospective observational study investigated the relationships between symmetry-based (SBMs), performance-based (PBMs), and functional outcome measures in THA patients to determine necessary or redundant categories of tests. The study material consisted of 24 patients with end-stage hip osteoarthritis scheduled for THA. The patients were examined one day before surgery and consecutively on the 4th day, 9th day, and 10th week postoperatively using the SBMs (weight-bearing chair-rising test, measurements of the maximal isometric torque of the quadriceps muscle); the PBMs (10-m walk, timed up-and-go, and stair-climbing tests); and the functional outcome measure (Harris Hip Score). The results obtained in a given category of tests at different time points were compared, and the correlations between the tests were determined. The reliability of the outcome measures was determined. The results of tests in the studied categories statistically significantly (p < 0.05) improved at the 10th week postoperatively compared to preoperative results. No strong correlations were revealed between the three studied types of outcome measures in THA patients. Therefore, none of them can be considered redundant. It also means that the relevance of symmetry for a core measurement set to describe the domain function in THA patients must be further clarified.

16.
Front Bioeng Biotechnol ; 10: 789629, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35237570

RESUMO

Total hip arthroplasty (THA) is an extremely successful treatment strategy. Patient expectations, however, have increased; if not properly guided by surgeons, at present, patients expect next to pain-free restoration of the joint and a fast return to work and sports. While the revision rates after THA also increased in younger patients, knowledge on musculoskeletal loads still remains sparse, and the current recommendations on postoperative rehabilitation are based on expert opinions only. The aim of this study was to unravel biomechanical contact conditions in "working age" (<60 years, 53.5 ± 3.0 years) and "retirement age" (>60 years, 67.7 ± 8.6 years) patients during activities recommended post-THA. We hypothesized that working age patients would show substantially increased hip contact loads compared to older patients. The in vivo joint contact force (F res) and torsion torque (M tors), reflecting the main contact load situation, experienced during activities of daily living and sports activities were measured in a unique group of 16 patients with instrumented THA. We summarized patient activities and sports recommendations after THA mentioned within the literature using PubMed (without claim of completeness). The measurements showed that younger working age patients experienced significant (p = 0.050) increased M tors (21.52 ± 9.11 Nm) than older retirement age patients (13.99 ± 7.89 Nm) by walking. Bowling, as a recommended low-impact sport, was associated with F res of up to 5436 N and M tors of up to 108 Nm in the working age group, which were higher than the F res (5276 N) and M tors (71 Nm) during high-impact soccer. Based on our results, age was proven to be a discriminator in joint loading, with working age patients presenting with increased loads compared to retirement age patients, already during daily activities. The current patient recommendations have led to further increased joint loadings. If THA cannot be delayed in a patient, we propose counselling patients on a carefully considered return to sports, focusing on low-impact activities, as indicated hereby. The findings from this work illustrate the need to provide critical feedback to patient expectations when returning to work and sports activities. Patients returning to more intensive sports activities should be carefully monitored and advised to avoid as much overloading as possible.

17.
Front Bioeng Biotechnol ; 10: 813345, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35284427

RESUMO

This study aimed to characterize ipsilateral loading and return to weight-bearing symmetry (WBS) in patients undergoing total hip arthroplasty (THA) during activities of daily living (ADLs) using instrumented insoles. A prospective study in 25 THA patients was performed, which included controlled pre- and postoperative follow-ups in a single rehabilitation center of an orthopedic department. Ipsilateral loading and WBS of ADLs were measured with insoles in THA patients and in a healthy control group of 25 participants. Measurements in the THA group were performed at 4 different visits: a week pre-THA, within a week post-THA, 3-6 weeks post-THA, and 6-12 weeks post-THA, whereas the healthy control group was measured once. ADLs included standing comfortably, standing evenly, walking, and sit-to-stand-to-sit (StS) transitions. All ADLs were analyzed using discrete methods, and walking included a time-scale analysis to provide temporal insights in the ipsilateral loading and WBS waveforms. THA patients only improved beyond their pre-surgery levels while standing comfortably (ipsilateral loading and WBS, p < 0.05) and during StS transitions (WBS, p < 0.05). Nevertheless, patients improved upon their ipsilateral loading and WBS deficits observed within a week post-surgery across all investigated ADLs. Ipsilateral loading and WBS of THA patients were comparable to healthy participants at 6-12 weeks post-THA, except for ipsilateral loading during walking (p < 0.05) at the initial and terminal double-leg support period of the stance phase. Taken together, insole measurements allow for the quantification of ipsilateral loading and WBS deficits during ADLs, identifying differences between pre- and postoperative periods, and differentiating THA patients from healthy participants. However, post-THA measurements that lack pre-surgery assessments may not be sensitive to identifying patient-specific improvements in ipsilateral loading and WBS. Moreover, StS transitions and earlier follow-up time points should be considered an important clinical metric of biomechanical recovery after THA.

18.
J Bone Joint Surg Am ; 103(2): 146-154, 2021 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-33060427

RESUMO

BACKGROUND: The apparently physiological kinematics of the bicruciate-stabilized total knee arthroplasty (BCS TKA) systems have been attributed to the anterior and posterior post-cam mechanism. Although comparisons between TKA designs with either a retained or a sacrificed cruciate ligament have been conducted, we are not aware of any analyses of 2 implants with identical bearing geometry but different cruciate-ligament strategies under equal loading conditions. Knowledge about the kinematic effect of the different cruciate ligament strategies would potentially be valuable to facilitate preoperative planning and decision-making with regard to selecting the most appropriate implant for a patient. METHODS: This retrospective study included 20 patients: 10 treated with a BCS and 10 treated with a cruciate retaining (CR) TKA. Fluoroscopic analyses during high-flexion activities (unloaded flexion-extension and loaded lunge) were conducted at 24 months postsurgery. All patients completed the Knee Society Score, Forgotten Joint Score, and High-Flexion Knee Score questionnaires preoperatively and postoperatively. RESULTS: The BCS cohort showed greater femoral lateral rollback as well as a medial pivot in both activities. In contrast, the CR cohort showed a significant increase in anterior translation on the medial compartment as well as almost absent femoral lateral rollback. Higher clinical scores were observed in the BCS cohort. CONCLUSIONS: At 24 months postsurgery, despite equal bearing geometry, retention of the posterior cruciate ligament in the CR cohort apparently was insufficient to reduce anterior shift. The BCS cohort showed expected knee joint kinematics; however, the kinematics in this cohort could eventually benefit from a smooth transition between the interchanging surfaces. Further investigation should be focused on the surgical technique and its interaction with the TKA design. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Artroplastia do Joelho/métodos , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/fisiopatologia , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Fenômenos Biomecânicos , Feminino , Humanos , Traumatismos do Joelho/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho/efeitos adversos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos
19.
Front Bioeng Biotechnol ; 9: 754715, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34820363

RESUMO

Some approaches in total knee arthroplasty aim for an oblique joint line to achieve an even medio-lateral load distribution across the condyles during the stance phase of gait. While there is much focus on the angulation of the joint line in static frontal radiographs, precise knowledge of the associated dynamic joint line orientation and the internal joint loading is limited. The aim of this study was to analyze how static alignment in frontal radiographs relates to dynamic alignment and load distribution, based on direct measurements of the internal joint loading and kinematics. A unique and novel combination of telemetrically measured in vivo knee joint loading and simultaneous internal joint kinematics derived from mobile fluoroscopy ("CAMS-Knee dataset") was employed to access the dynamic alignment and internal joint loading in 6 TKA patients during level walking. Static alignment was measured in standard frontal postoperative radiographs while external adduction moments were computed based on ground reaction forces. Both static and dynamic parameters were analyzed to identify correlations using linear and non-linear regression. At peak loading during gait, the joint line was tilted laterally by 4°-7° compared to the static joint line in most patients. This dynamic joint line tilt did not show a strong correlation with the medial force (R 2: 0.17) or with the mediolateral force distribution (pseudo R 2: 0.19). However, the external adduction moment showed a strong correlation with the medial force (R 2: 0.85) and with the mediolateral force distribution (pseudo R 2: 0.78). Alignment measured in static radiographs has only limited predictive power for dynamic kinematics and loading, and even the dynamic orientation of the joint line is not an important factor for the medio-lateral knee load distribution. Preventive and rehabilitative measures should focus on the external knee adduction moment based on the vertical and horizontal components of the ground reaction forces.

20.
Bone Joint J ; 102-B(1): 132-136, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31888367

RESUMO

AIMS: We report the natural course of Baker's cysts following total knee arthroplasty (TKA) at short- and mid-term follow-up. METHODS: In this prospective case series, 105 TKA patients were included. All patients who received surgery had a diagnosis of primary osteoarthritis and had preoperatively presented with a Baker's cyst. Sonography and MRI were performed to evaluate the existence and the gross size of the cyst before TKA, and sonography was repeated at a mean follow-up time of 1.0 years (0.8 to 1.3; short-term) and 4.9 years (4.0 to 5.6; mid-term) after TKA. Symptoms potentially attributable to the Baker's cyst were recorded at each assessment. RESULTS: At the one-year follow-up analysis, 102 patients were available. Of those, 91 patients were available for the 4.9-year assessment (with an 86.7% follow-up rate (91/105)). At the short- and mid-term follow-up, a Baker's cyst was still present in 87 (85.3%) and 30 (33.0%) patients, respectively. Of those patients who retained a Baker's cyst at the short-term follow-up, 31 patients (35.6%) had popliteal symptoms. Of those patients who continued to have a Baker's cyst at the mid-term follow-up, 17 patients (56.7%) were still symptomatic. The mean preoperative cyst size was 14.5 cm2 (13.1 to 15.8). At the short- and mid-term follow-up, the mean cyst size was 9.7 cm2 (8.3 to 11.0) and 10.4 cm2 (9.8 to 11.4), respectively. A significant association was found between the size of the cyst at peroperatively and the probability of resolution, with lesions smaller than the median having an 83.7% (36/43) probability of resolution, and larger lesions having a 52.1% (25/48) probability of resolution (p < 0.001). At the mid-term follow-up, no association between cyst size and popliteal symptoms was found. CONCLUSION: At a mean follow-up of 4.9 years (4.0 to 5.6) after TKA, the majority (67.0%, 61/91) of the Baker's cysts that were present preoperatively had disappeared. The probability of cyst resolution was dependent on the size of the Baker's cyst at baseline, with an 83.7% (36/43) probability of resolution for smaller cysts and 52.1% (25/48) probability for larger cysts. Cite this article: Bone Joint J. 2020;102-B(1):132-136.


Assuntos
Artroplastia do Joelho/métodos , Cisto Popliteal/patologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/patologia , Osteoartrite do Joelho/cirurgia , Cisto Popliteal/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA