RESUMO
BACKGROUND: The MOMENTUM 3 study (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) has demonstrated that the HeartMate 3 (HM3) pump is associated with reduced strokes compared with the HeartMate II (HMII) device. We now perform a comprehensive analysis of stroke events to evaluate their longitudinal occurrence, clinical correlates, patterns, and impact on outcome across the 2-year duration of support. METHODS: MOMENTUM 3 is a randomized controlled trial of the HM3 centrifugal-flow pump versus the HMII axial-flow pump in patients with advanced heart failure, regardless of the intended goal of support (bridge to transplantation or destination therapy). Baseline and postimplantation clinical correlates of stroke events were assessed with multivariable analyses. Longitudinal patterns, including device association, type of stroke (hemorrhagic versus ischemic), changing severity of impairment assessed with the modified Rankin Scale (disabling [modified Rankin Scale score >3] versus nondisabling [modified Rankin Scale score ≤3]) over time, and association with outcome, were determined. RESULTS: In 361 patients with the intended implant (189 HM3 and 172 HMII), 65 strokes (40 ischemic strokes and 25 hemorrhagic strokes) occurred in 52 patients at a median of 131 (range, 1-733) days. No difference in stroke rate was noted between 0 and 180 days of follow-up between devices. However, stroke incidence in the long-term period (181-730 days after left ventricular assist device) was 3.3 times lower for the HM3 group (HM3: 0.04 versus HMII: 0.13 events per patient-year; odds ratio, 0.23; 95% CI, 0.08-0.63; P=0.01). Treatment with the HM3 pump was the only independent predictor of lower stroke events. We found no direct association of blood pressure or antithrombotic regimens with observed stroke rates. A stroke event significantly lowered 2-year postimplantation survival regardless of subtype or initial severity of neurological impairment compared with patients without a stroke (43±12% for hemorrhagic stroke, 57±9% for ischemic stroke, 51±11% for disabling, and 51±11% for nondisabling compared with 85±2% 2-year survival for patients without stroke). CONCLUSIONS: The HM3 pump is associated with a marked reduction in stroke rates compared with the HMII device, with benefits observed in the long-term period (>6 months). The occurrence of stroke of any type (hemorrhagic and ischemic) or of any functional severity (disabling and nondisabling) is predictive of a poor 2-year clinical outcome. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/ . Unique identifier: NCT02224755.
Assuntos
Isquemia Encefálica/prevenção & controle , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hemorragias Intracranianas/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Idoso , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/mortalidade , Isquemia Encefálica/fisiopatologia , Avaliação da Deficiência , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Hemorragias Intracranianas/diagnóstico , Hemorragias Intracranianas/mortalidade , Hemorragias Intracranianas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular EsquerdaRESUMO
BACKGROUND: Worsening heart failure (HF) and health-related quality of life (HRQOL) have been shown to impact the decision to proceed with left ventricular assist device (LVAD) implantation, but little is known about how socioeconomic factors influence expressed patient preference for LVAD. METHODS AND RESULTS: Ambulatory patients with advanced systolic HF (n=353) reviewed written information about LVAD therapy and completed a brief survey to indicate whether they would want an LVAD to treat their current level of HF. Ordinal logistic regression analyses identified clinical and demographic predictors of LVAD preference. Higher New York Heart Association (NYHA) class, worse HRQOL measured by Kansas City Cardiomyopathy Questionnaire, lower education level, and lower income were significant univariable predictors of patients wanting an LVAD. In the multivariable model, higher NYHA class (OR [odds ratio]: 1.43, CI [confidence interval]: 1.08-1.90, Pâ¯=â¯.013) and lower income level (OR: 2.10, CI: 1.18 - 3.76, Pâ¯=â¯.012 for <$40,000 vs >$80,000) remained significantly associated with wanting an LVAD. CONCLUSION: Among ambulatory patients with advanced systolic HF, treatment preference for LVAD was influenced by level of income independent of HF severity. Understanding the impact of socioeconomic factors on willingness to consider LVAD therapy may help tailor counseling towards individual needs.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Qualidade de Vida , Fatores Socioeconômicos , Resultado do TratamentoRESUMO
BACKGROUND: With the limited number of available suitable donor hearts resulting in plateaued numbers of heart transplantations, short- and long-term mechanical circulatory support devices, including the implantation of total artificial hearts (TAHs) are modalities that are increasingly being used as treatment options for patients with end-stage heart failure. The superior vena cava syndrome has been described in this context in various disease processes. We report successful venoplasty for superior vena cava syndrome in a patient with a TAH. CASE PRESENTATION: A 65-year-old man with a history of nonischemic cardiomyopathy had received a left ventricular assist device, and then 2 years later, underwent orthotopic heart transplantation using the bicaval anastomosis technique. The postprocedural course was complicated by primary graft failure, resulting in the need for implantation of a TAH. About 5 months after TAH implantation, he started to develop complications such as volume retention, swelling of the upper extremities, and was diagnosed to have a superior vena cava syndrome. The patient underwent a successful venoplasty of his superior vena cava by interventional radiology with resolution of upper body edema, normalization of renal, and liver function. CONCLUSION: Potential fatal complications caused by catheter or wire entrapment in the right-sided mechanical valve of a TAH have been reported. We describe a safe method for the treatment of superior vena cava syndrome in patients with TAH.
Assuntos
Transplante de Coração/efeitos adversos , Transplante de Coração/métodos , Coração Artificial/efeitos adversos , Coração Auxiliar/efeitos adversos , Disfunção Primária do Enxerto/etiologia , Síndrome da Veia Cava Superior/etiologia , Síndrome da Veia Cava Superior/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Veia Cava Superior/cirurgia , Idoso , Constrição Patológica/cirurgia , Humanos , Masculino , Radiografia Intervencionista , Cirurgia Assistida por Computador/métodos , Resultado do Tratamento , Veia Cava Superior/patologiaRESUMO
A 71-year-old woman was admitted with acute hypoxic and hypercapnic respiratory failure and cardiogenic shock, secondary to acute on chronic biventricular systolic and diastolic congestive heart failure and severe aortic and mitral valve stenosis. She further presented with pulmonary hypertension and moderate-to-severe tricuspid regurgitation requiring high and increasing doses of vasopressors. The patient was percutaneously cannulated for venoarterial extracorporeal membrane oxygenation (VA-ECMO) and stabilized on ECMO, with a urine output of 17.3 L within the following 8 days. Balloon valvuloplasty and/or transcatheter aortic valve replacement were discussed but ruled out by the multidisciplinary team considering the mitral valve could not be fully addressed. Though lung function was not fully optimized, a window of opportunity was identified and used for double valve replacement on day 8 of VA-ECMO support. After a 24-hour vasoplegic period, the patient was extubated to continuous positive airway pressure and further transitioned to nasal cannula, following which she recovered well.
Assuntos
Estenose da Valva Aórtica/cirurgia , Oxigenação por Membrana Extracorpórea/métodos , Insuficiência Cardíaca/terapia , Estenose da Valva Mitral/cirurgia , Choque Cardiogênico/terapia , Idoso , Estenose da Valva Aórtica/complicações , Feminino , Insuficiência Cardíaca/etiologia , Implante de Prótese de Valva Cardíaca , Humanos , Estenose da Valva Mitral/complicações , Choque Cardiogênico/etiologiaRESUMO
BACKGROUND: Mechanical circulatory support is now a proven therapy for the treatment of patients with advanced heart failure and cardiogenic shock. The role for this therapy in patients with less severe heart failure is unknown. OBJECTIVE: The objective of this study is to examine the impact of mechanically assisted circulation using the HeartMate II left ventricular assist device in patients who meet current US Food and Drug Administration-defined criteria for treatment but are not yet receiving intravenous inotropic therapy. METHODS: This is a prospective, nonrandomized clinical trial of 200 patients treated with either optimal medical management or a mechanical circulatory support device. CLINICAL CONTEXT: This trial will be the first prospective clinical evaluation comparing outcomes of patients with advanced ambulatory heart failure treated with either ongoing medical therapy or a left ventricular assist device. It is anticipated to provide novel insights regarding relative outcomes with each treatment and an understanding of patient and provider acceptance of the ventricular assist device therapy. This trial will also provide information regarding the risk of events in "stable" patients with advanced heart failure and guidance for the optimal timing of left ventricular assist device therapy.
Assuntos
Circulação Assistida , Cardiotônicos/administração & dosagem , Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Esquerda/complicações , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Assistência Ambulatorial/métodos , Circulação Assistida/instrumentação , Circulação Assistida/métodos , Pesquisa Comparativa da Efetividade , Gerenciamento Clínico , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Medição de Risco , Índice de Gravidade de Doença , Choque Cardiogênico/etiologia , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/terapia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Disfunção Ventricular Esquerda/fisiopatologiaRESUMO
BACKGROUND: Recent reports suggested that HeartMate II (HMII) thrombosis rates may be higher in implants after 2011. We characterize events at HMII centers (>100 HMII implants) whose device thrombosis rates are equivalent or lower than reported by INTERMACS. METHODS: Seven centers pooled implants from 2011 through June 2013 to examine pump thrombus and identify characteristics and clinical strategies that potentially mitigate the risk. A total of 666 patients (age 59 ± 13 years; 81% male) were studied (support duration: 13.7 ± 8.3 months, cumulative: 759 patient years). Median target INR was 2.25 (range 2.0 to 2.5), and median pump speed was 9200 rpm (range 8600 to 9600). Pump thrombus was suspected with clinical evidence (e.g., hemolysis, positive ramp test) requiring intervention (e.g., anticoagulation therapy, pump exchange) or patient death. RESULTS: Suspected pump thrombus occurred in 24/666 (3.6%) patients within three months of implant. At six months, 38/666 (5.7%) had suspected pump thrombus including 24 (3.6%) resulting in pump exchange or death. Stroke (hemorrhagic: 0.049, and ischemic: 0.048 events/patient year) and survival (six months: 88 ± 1%; 1 year: 81 ± 2%) were consistent with national averages. Suspected pump thrombus patients were younger (55 ± 13 vs. 59 ± 13, p = 0.046) and had more females (31.6% vs. 18.3%, p = 0.054). There was no difference in indication, etiology of heart failure, or body size. CONCLUSIONS: This analysis demonstrates low HMII thrombus events. Minimization of risk factors by uniform implant techniques and consistent post-op management may reduce device thrombosis. A larger scale multicenter evaluation may better elucidate the difference in thrombus events between centers.
Assuntos
Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Trombose/epidemiologia , Trombose/etiologia , Adulto , Fatores Etários , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/métodos , Fatores de Risco , Fatores Sexuais , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Trombose/prevenção & controle , Fatores de TempoRESUMO
Background: Patients with heart failure face increased morbidity and mortality when infected with COVID-19. The objective of this study was to evaluate the outcomes of patients with Heart Failure (HF), Left Ventricular Assist Devices (LVADs), or Heart Transplants (HTx) diagnosed with COVID-19 within an advanced HF practice. Methods: Out of 2635 patients followed, 96 patients were diagnosed with COVID-19 between March 2020 and January 2021. Median hospital length of stay (LOS), requirement for mechanical ventilation (MV), and mortality rate were evaluated. Results: The distribution of COVID-19 among the 96 patients was: HF = 43 (45 %), LVAD = 16 (17 %) and HTx = 37 (38 %). Among 43 HF patients, 5 (12 %) died, 18 (42 %) required hospitalization with an LOS of 7 days, 5 (12 %) required ICU and 4 (9 %) required MV. Of the 16 LVAD patients, 2 (13 %) died, 8 (50 %) required hospitalization with an LOS of 11 days, 3 (19 %) required ICU and 3 (19 %) required MV. Among 37 HTx patients, 7 (19 %) died, 23 (62 %) required hospitalization with an LOS of 9 days, 6 (16 %) required ICU and 6 (16 %) required MV. Conclusion: This report is among the first to describe the impact of COVID-19 on a diverse advanced HF practice. It highlights the risks associated with COVID-19 faced by the HF, LVAD and HTx patients. A 90-day mortality rate of 19 % with HTx patients acquiring COVID-19 is ominous as is a mortality rate of 12 % each for HF and LVAD patients. This clinical impact should serve as a reminder of unique challenges with these populations.
RESUMO
Infection is a serious adverse event limiting left ventricular assist device (LVAD) therapy in advanced heart failure patients, but a reliable means to identify patients at increased risk of infection is still lacking. We hypothesized that preoperative elevated levels of plasma Oncostatin M (OSM), a cytokine marker of leukocyte activation and inflammation, would be predictive of subsequent infection. We measured plasma OSM in 41 LVAD patients one day before LVAD implantation and postoperatively over two months. Preoperative plasma OSM levels were normal in 27 patients (group A, 4.9 ± 3.2 pg/ml) but elevated in 14 patients (group B, 1649.0 ± 458.9 pg/ml) ( p = 0.003). Early postoperative levels rose in both groups and declined rapidly in group A, with group B declining slowly over two months. Significantly more infections developed in group B than group A patients over two months postimplantation ( p = 0.004). No other routine clinical assessment or laboratory testing afforded this differentiation. These findings suggest that preoperative plasma OSM levels may assist in identifying patients at increased risk of infections after LVAD implantation.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Biomarcadores , Coração Auxiliar/efeitos adversos , Humanos , Oncostatina M , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Several distinctly engineered left ventricular assist devices (LVADs) are in clinical use. However, contemporaneous real world comparisons have not been conducted, and clinical trials were not powered to evaluate differential survival outcomes across devices. OBJECTIVES: Determine real world survival outcomes and healthcare expenditures for commercially available durable LVADs. METHODS: Using a retrospective observational cohort design, Medicare claims files were linked to manufacturer device registration data to identify de-novo, durable LVAD implants performed between January 2014 and December 2018, with follow-up through December 2019. Survival outcomes were compared using a Cox proportional hazards model stratified by LVAD type and validated using propensity score matching. Healthcare resource utilization was analyzed across device types by using nonparametric bootstrap analysis methodology. Primary outcome was survival at 1-year and total Part A Medicare payments. RESULTS: A total of 4,195 de-novo LVAD implants were identified in fee-for-service Medicare beneficiaries (821 HeartMate 3; 1,840 HeartMate II; and 1,534 Other-VADs). The adjusted hazard ratio for mortality at 1-year (confirmed in a propensity score matched analysis) for the HeartMate 3 vs HeartMate II was 0.64 (95% CI; 0.52-0.79, p< 0.001) and for the HeartMate 3 vs Other-VADs was 0.51 (95% CI; 0.42-0.63, p < 0.001). The HeartMate 3 cohort experienced fewer hospitalizations per patient-year vs Other-VADs (respectively, 2.8 vs 3.2 EPPY hospitalizations, p < 0.01) and 6.1 fewer hospital days on average (respectively, 25.2 vs 31.3 days, p < 0.01). The difference in Medicare expenditures, conditional on survival, for HeartMate 3 vs HeartMate II was -$10,722, p < 0.001 (17.4% reduction) and for HeartMate 3 vs Other-VADs was -$17,947, p < 0.001 (26.1% reduction). CONCLUSIONS: In this analysis of a large, real world, United States. administrative dataset of durable LVADs, we observed that the HeartMate 3 had superior survival, reduced healthcare resource use, and lower healthcare expenditure compared to other contemporary commercially available LVADs.
Assuntos
Gastos em Saúde/estatística & dados numéricos , Insuficiência Cardíaca/terapia , Transplante de Coração , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Pontuação de Propensão , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia , Listas de Espera/mortalidadeRESUMO
Background Heart failure (HF) imposes significant burden on patients and caregivers. Longitudinal data on caregiver health-related quality of life (HRQOL) and burden in ambulatory advanced HF are limited. Methods and Results Ambulatory patients with advanced HF (n=400) and their participating caregivers (n=95) enrolled in REVIVAL (Registry Evaluation of Vital Information for VADs [Ventricular Assist Devices] in Ambulatory Life) were followed up for 24 months, or until patient death, left ventricular assist device implantation, heart transplantation, or loss to follow-up. Caregiver HRQOL (EuroQol Visual Analog Scale) and burden (Oberst Caregiving Burden Scale) did not change significantly from baseline to follow-up. At time of caregiver enrollment, better patient HRQOL by Kansas City Cardiomyopathy Questionnaire was associated with better caregiver HRQOL (P=0.007) and less burden by both time spent (P<0.0001) and difficulty (P=0.0007) of caregiving tasks. On longitudinal analyses adjusted for baseline values, better patient HRQOL (P=0.034) and being a married caregiver (P=0.016) were independently associated with better caregiver HRQOL. Patients with participating caregivers (versus without) were more likely to prefer left ventricular assist device therapy over time (odds ratio, 1.43; 95% CI, 1.03-1.99; P=0.034). Among patients with participating caregivers, those with nonmarried (versus married) caregivers were at higher composite risk of HF hospitalization, death, heart transplantation or left ventricular assist device implantation (hazard ratio, 2.99; 95% CI, 1.29-6.96; P=0.011). Conclusions Patient and caregiver characteristics may impact their HRQOL and other health outcomes over time. Understanding the patient-caregiver relationship may better inform medical decision making and outcomes in ambulatory advanced HF.
Assuntos
Cuidadores/psicologia , Insuficiência Cardíaca/terapia , Qualidade de Vida , Idoso , Efeitos Psicossociais da Doença , Feminino , Transplante de Coração , Coração Auxiliar , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Prospectivos , Sistema de Registros , Análise de RegressãoRESUMO
BACKGROUND: Left ventricular assist devices (LVADs) are increasingly being used in patients with advanced heart failure as bridge to transplant, bridge to decision, or destination therapy. Infections are a major complication associated with LVADs. Staphylococcus aureus is one of the common causative organisms associated with LVAD infections. Methicillin resistant staphylococcus aureus (MRSA)-colonized patients are at an increased risk for developing MRSA-associated infections. Various studies have demonstrated decolonization of skin with topical chlorhexidine and nares with 2% intranasal mupirocin ointment is effective in reducing MRSA-associated infections. OBJECTIVE: The objective of this observational study was to examine the impact of a universal decolonization protocol using topical chlorhexidine and intranasal mupirocin ointment for 5 days before LVAD implantation on postoperative infections (30, 60, and 90 days) and 30-day infection-related rehospitalization. METHODS: A preoperative universal decolonization with 4% chlorhexidine daily whole-body bath and 2% intranasal mupirocin ointment twice a day for 5 days was implemented for patients undergoing elective LVAD implantation. Using an observational study design, we included a convenience sample of 84 subjects who were established patients in an accredited advanced heart failure program. Thirty-seven patients served in the standard protocol group, and 47 in the universal decolonization protocol group participated in the observational study. RESULTS: In the standard protocol group, there were 4 MRSA infections with none in the universal decolonization group (χ = 5.34, P = .03). In total, there were 8 surgical site infections in the standard protocol group and 1 in the universal decolonization group (χ = 5.95, P = .01). CONCLUSION: A 5-day universal decolonization protocol before LVAD implantation was effective in reducing total infections as well as MRSA-specific infections.
Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Antibacterianos/uso terapêutico , Clorexidina/uso terapêutico , Humanos , Mupirocina/uso terapêutico , Complicações Pós-Operatórias/prevenção & controle , Infecções Estafilocócicas/tratamento farmacológicoRESUMO
BACKGROUND: Ambulatory patients with advanced heart failure (HF) are often considered for advanced therapies, including durable mechanical circulatory support (MCS). The Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) profiles are a commonly used descriptor of disease severity in patients receiving MCS devices, but their role in defining the prognosis of ambulatory patients is less well established, especially for Profiles 6 and 7. METHODS: Registry Evaluation of Vital Information on Ventricular Assist Devices in Ambulatory Life is a prospective observational study of 400 outpatients from 21 MCS and cardiac transplant centers. Eligible patients had New York Heart Association Class II to IV symptoms despite optimal medical and electrical therapies with a recent HF hospitalization, heart transplant listing, or evidence of high neurohormonal activation. RESULTS: The cohort included 33 INTERMACS Profile 4 (8%), 83 Profile 5 (21%), 155 Profile 6 (39%), and 129 Profile 7 (32%). Across INTERMACS profiles, there were no differences in age, gender, ejection fraction, blood pressure, or use of guideline-directed medical therapy. A lower INTERMACS profile was associated with more hospitalizations, greater frailty, and more impaired functional capacity and quality of life. The composite end point of death, durable MCS, or urgent transplant at 12 months occurred in 39%, 27%, 24%, and 14% subjects with INTERMACS Profiles 4, 5, 6, and 7, respectively (pâ¯=â¯0.004). CONCLUSIONS: Among ambulatory patients with advanced HF, a lower INTERMACS profile was associated with a greater burden of HF across multiple dimensions and a higher composite risk of durable MCS, urgent transplant, or death. These profiles may assist in risk assessment and triaging ambulatory patients to advanced therapies.
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Pacientes Ambulatoriais , Sistema de Registros , Medição de Risco/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hospitalização/tendências , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Qualidade de Vida , Adulto JovemRESUMO
BACKGROUND: Patients with heart failure (HF) often have multiple chronic conditions that may impact health-related quality of life (HRQOL) despite HF therapy. We sought to determine the association between noncardiac comorbidities and HRQOL in ambulatory patients with advanced HF. METHODS: Baseline data from 373 subjects in REVIVAL (Registry Evaluation of Vital Information for Ventricular Assist Devices in Ambulatory Life) were analyzed using multivariable general linear models to evaluate the relationship between comorbidities and HRQOL (EuroQol Visual Analogue Scale, EQ-5D-3L Index Score, and Kansas City Cardiomyopathy Questionnaire). The primary independent variables were a comorbidity index (sum of 14 noncardiac conditions), a residual comorbidity index (without depression), and depression alone. The median (25th to 75th percentile) number of comorbidities was 3 (2-4). RESULTS: Increasing comorbidity burden was associated with a reduction in generic (EQ-5D Index, P=0.005) and HF-specific (Kansas City Cardiomyopathy Questionnaire, P=0.001) HRQOL. The residual comorbidity index was not associated with HRQOL when depression included in the model independently, while depression was associated with HRQOL across all measures. Participants with depression (versus without) scored on average 13 points (95% CI, 8-17) lower on the EuroQol Visual Analogue Scale, 0.15 points (95% CI, 0.12-0.18) lower on the EQ-5D Index, and 24.9 points (95% CI, 21.2-28.5) lower on the Kansas City Cardiomyopathy Questionnaire overall summary score. CONCLUSIONS: While noncardiac comorbidities were prevalent in ambulatory advanced HF patients, only depression was associated with decreased generic and HF-specific HRQOL. Other than depression, the presence of noncardiac comorbidities should not impact expected gains in HRQOL following ventricular assist device implantation, provided the conditions are not a contraindication to implant. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01369407.
Assuntos
Depressão/epidemiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/instrumentação , Qualidade de Vida , Idoso , Comorbidade , Estudos Transversais , Depressão/diagnóstico , Feminino , Nível de Saúde , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Sistema de Registros , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Estados Unidos/epidemiologiaRESUMO
Evaluation of left ventricular devices is becoming increasingly important as the implantation of these devices increases. Cardiac computed tomography angiography (CCTA) has many potential advantages compared with plain radiographs and echocardiography to troubleshoot these devices and potentially help guide therapy. Heart failure (HF) remains a deadly, progressive disease with substantive and increasing morbidity, mortality, cost, and prevalence. Use of left ventricular assist devices (LVAD) as treatment for refractory HF has been steadily rising during the last decade. Seventy-four LVAD recipients who met an indication for CCTA were referred for scanning at our center for a total of 94 studies. All recipients had received a Heart Mate II (Thoratec, Pleasanton, CA) LVAD at a previous time. All patients underwent gated CCTA on a 320 row multidetector scanner (Aquilion ONE, Toshiba Medical Systems, Irvine, California, USA). Images were then reconstructed and analysis was performed using multiple oblique views. All 94 studies had technically good images. In survival analysis, 43 of the 74 LVAD patients had normal CCTA findings while 31 had abnormal CCTA results. The 6, 12, and 18 months survival was 93%, 79%, and 77% in those with normal results and 71%, 61%, and 61%, respectively, in the abnormal CCTA findings. Overall survival was statistically significant in when comparing the two groups (p = 0.003). Cardiac computed tomography angiography may be used as an aid for risk stratification and a potential indicator of short- and long-term prognosis in LVAD patients.
Assuntos
Coração Auxiliar , Tomografia Computadorizada Multidetectores/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Análise de SobrevidaRESUMO
BACKGROUND: The ROADMAP study showed survival with improved functional status was better with left ventricular assist device (LVAD) therapy compared with optimal medical management (OMM) in ambulatory, non-inotrope-dependent (INTERMACS [IM] Profile 4 to 7) patients. To study more balanced cohorts and better define which patients may benefit from implantation of an LVAD, we re-evaluated the patients enrolled in ROADMAP when stratified by INTERMACS profile (Profile 4 and Profiles 5 to 7). METHODS: The primary end-point (survival on original therapy with improvement in 6-minute walk distance ≥75 meters at 1 year), actuarial survival, adverse events (AEs) and health-related quality of life (HRQoL) were evaluated. RESULTS: For INTERMACS Profile 4 (IM4), more LVAD patients met the primary end-point compared with OMM patients (40% vs 15%; odds ratio = 3.9 [1.2 to 12.7], p = 0.024), but there was no statistically significant difference for INTERMACS Profiles IM 5 to 7 (IM5-7). Event-free survival on original therapy at 2 years was greater for LVAD than for OMM patients in both IM4 (67% vs 28%; p < 0.001) and IM5-7 (76% vs 49%; p = 0.025) profile groups. Composite end-points of survival on original therapy with improved HRQoL or depression were better with LVAD than OMM in IM4, but not IM5-7. AEs trended higher in LVAD compared with OMM patients in both profile groups. Rehospitalization rates for LVAD vs OMM were similar between treatment arms in IM4 (82% vs 86%; p = 0.780), but were higher for LVAD in IM5-7 (93% vs 71%; p = 0.016). CONCLUSIONS: LVAD patients in IM4, but not IM5-7, are more likely to meet the primary end-point and have improvements in HRQoL and depression compared with OMM, even with AEs generally being more frequent. LVAD therapy with current technology may be beneficial in select IM4 patients, but can be deferred for most IM5-7 patients, who should be followed closely due to the high frequency of treatment failures.
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Idoso , Feminino , Insuficiência Cardíaca/classificação , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Taxa de Sobrevida , Resultado do Tratamento , Teste de CaminhadaRESUMO
OBJECTIVES: The authors sought to provide the pre-specified primary endpoint of the ROADMAP (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients) trial at 2 years. BACKGROUND: The ROADMAP trial was a prospective nonrandomized observational study of 200 patients (97 with a left ventricular assist device [LVAD], 103 on optimal medical management [OMM]) that showed that survival with improved functional status at 1 year was better with LVADs compared with OMM in a patient population of ambulatory New York Heart Association functional class IIIb/IV patients. METHODS: The primary composite endpoint was survival on original therapy with improvement in 6-min walk distance ≥75 m. RESULTS: Patients receiving LVAD versus OMM had lower baseline health-related quality of life, reduced Seattle Heart Failure Model 1-year survival (78% vs. 84%; p = 0.012), and were predominantly INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 4 (65% vs. 34%; p < 0.001) versus profiles 5 to 7. More LVAD patients met the primary endpoint at 2 years: 30% LVAD versus 12% OMM (odds ratio: 3.2 [95% confidence interval: 1.3 to 7.7]; p = 0.012). Survival as treated on original therapy at 2 years was greater for LVAD versus OMM (70 ± 5% vs. 41 ± 5%; p < 0.001), but there was no difference in intent-to-treat survival (70 ± 5% vs. 63 ± 5%; p = 0.307). In the OMM arm, 23 of 103 (22%) received delayed LVADs (18 within 12 months; 5 from 12 to 24 months). LVAD adverse events declined after year 1 for bleeding (primarily gastrointestinal) and arrhythmias. CONCLUSIONS: Survival on original therapy with improvement in 6-min walk distance was superior with LVAD compared with OMM at 2 years. Reduction in key adverse events beyond 1 year was observed in the LVAD group. The ROADMAP trial provides risk-benefit information to guide patient- and physician-shared decision making for elective LVAD therapy as a treatment for heart failure. (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients [ROADMAP]; NCT01452802).
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar/estatística & dados numéricos , Cardiotônicos/uso terapêutico , Teste de Esforço , Tolerância ao Exercício , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/efeitos adversos , Humanos , Estudos Prospectivos , Qualidade de Vida , Medição de Risco , Resultado do TratamentoRESUMO
BACKGROUND: Data for left ventricular assist devices (LVADs) in patients with noninotrope-dependent heart failure (HF) are limited. OBJECTIVES: The goal of this study was to evaluate HeartMate II (HMII) LVAD support versus optimal medical management (OMM) in ambulatory New York Heart Association functional class IIIB/IV patients meeting indications for LVAD destination therapy but not dependent on intravenous inotropic support. METHODS: This was a prospective, multicenter (N = 41), observational study of 200 patients (97 LVAD, 103 OMM). Entry criteria included ≥1 hospitalization for HF in the last 12 months and 6-min walk distance (6MWD) <300 m. The primary composite endpoint was survival on original therapy with improvement in 6MWD ≥75 m at 12 months. RESULTS: LVAD patients were more severely ill, with more patients classified as Interagency Registry for Mechanically Assisted Circulatory Support profile 4 (65% LVAD vs. 34% OMM; p < 0.001) than 5 to 7. More LVAD patients met the primary endpoint (39% LVAD vs. 21% OMM; odds ratio: 2.4 [95% confidence interval: 1.2 to 4.8]; p = 0.012). On the basis of as-treated analysis, 12-month survival was greater for LVAD versus OMM (80 ± 4% vs. 63 ± 5%; p = 0.022) patients. Adverse events were higher in LVAD patients, at 1.89 events/patient-year (EPPY), primarily driven by bleeding (1.22 EPPY), than with OMM, at 0.83 EPPY, primarily driven by worsening HF (0.68 EPPY). Most patients (80% LVAD vs. 62% OMM; p < 0.001) required hospitalizations. Health-related quality of life (HRQol) and depression improved from baseline more significantly with LVADs than with OMM (Δ visual analog scale: 29 ± 25 vs. 10 ± 22 [p < 0.001]; Δ Patient Health Questionnaire-9: -5 ± 7 vs. -1 ± 5 [p < 0.001]). CONCLUSIONS: Survival with improved functional status was better with HMII LVAD compared with OMM. Despite experiencing more frequent adverse events, LVAD patients improved more in HRQol and depression. The results support HMII use in functionally limited, noninotrope-dependent HF patients with poor HRQoL. (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device [LVAD] and Medical Management [ROADMAP]; NCT01452802).
Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Idoso , Idoso de 80 Anos ou mais , Pesquisa Comparativa da Efetividade , Feminino , Insuficiência Cardíaca/tratamento farmacológico , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Medição de Risco , Resultado do Tratamento , Adulto JovemRESUMO
OBJECTIVES: A post-approval (PA) study for destination therapy (DT) was required by the Food and Drug Administration (FDA) to determine whether results with the HeartMate (HM) II (Thoratec, Pleasanton, California) left ventricular assist device (LVAD) in a commercial setting were comparable to results during the DT multicenter pivotal clinical trial. BACKGROUND: New device technology developed in the clinical research setting requires validation in a real-world setting. METHODS: The PA study was a prospective evaluation of the first 247 HM II patients identified pre-operatively as eligible for DT in the national INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) registry. Patients were enrolled from January to September 2010 at 61 U.S. centers and followed for 2 years. A historical comparison group included patients (n = 133 at 34 centers) enrolled in the primary data cohort in the DT pivotal trial (TR). Survival rates and adverse events for the PA group were obtained from the INTERMACS registry. RESULTS: Baseline characteristics were similar for PA versus TR. Forty-five percent of PA patients were in INTERMACS profiles 1 to 2 and 28% were in profile 3. Adverse events in the PA group were similar or lower than those in the TR group, including improvements in device-related infection (0.22 vs. 0.47) and post-operative bleeding requiring surgery (0.09 vs. 0.23) events per patient-year. Kaplan-Meier survival at 2 years was 62% (PA group) versus 58% (TR group). PA group survival at 1 and 2 years was 82 ± 5% and 69 ± 6% for INTERMACS profiles 4 to 7 (n = 63) versus 72 ± 3% and 60 ± 4% for profiles 1 to 3 (n = 184). The median length of stay after surgery was reduced by 6 days in the PA group versus the TR group. CONCLUSIONS: Results in a commercial patient care setting for the DT population supported the original pivotal clinical trial findings regarding the efficacy and risk profile of the HM II LVAD. Survival was best in patients who were not inotrope-dependent (INTERMACS profiles 4 to 7).
Assuntos
Aprovação de Equipamentos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Sistema de Registros , United States Food and Drug Administration , Adulto , California/epidemiologia , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taxa de Sobrevida/tendências , Estados UnidosRESUMO
Left ventricular assist devices (LVADs) are blood pumps that augment the function of the failing heart to improve perfusion, resulting in improved survival. For LVADs to effectively unload the left ventricle, the inflow cannula (IC) should be unobstructed and ideally aligned with the heart's mitral valve (MV). We examined IC orientation deviation from a hypothesized conventional angle (45° right-posterior) and the approximate angle for direct IC-MV alignment in many patients. Three-dimensional anatomic models were created from computed tomography scans for 24 LVAD-implanted patients, and angles were measured between the IC and the apical z-axis in both the coronal and the sagittal planes. Common surgical IC angulation was found to be 22 ± 15° rightward and 21 ± 12° posterior from the apical z-axis; 38% (n = 9) of patients fell in this range. Direct IC-MV angulation was found to be 34 ± 8° rightward and 15 ± 7° posterior; only 8% (n = 2) of patients fell in this range. Rightward deviation toward ventricular septal wall and anterior deviation toward LV anterior freewall are associated with mortalities more so than leftward and posterior deviation. In conclusion, anatomic reconstruction may be a useful preoperative tool to obtain general population and patient-specific alignment for optimal LVAD implantation.
Assuntos
Procedimentos Cirúrgicos Cardiovasculares/métodos , Ventrículos do Coração/anatomia & histologia , Coração Auxiliar , Imageamento Tridimensional , Modelos Anatômicos , Adulto , Idoso , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Procedimentos Cirúrgicos Cardiovasculares/instrumentação , Feminino , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios XRESUMO
A patient supported by a left ventricular assist device (LVAD) presented with an abdominal tumor requiring consolidative radiation therapy. To assess the effects of radiation therapy on the operation of the ventricular assist device (VAD) system and assure that the treatment would be safe for the patient with regard to the operation of the VAD system, sample equipment was irradiated and then tested for functionality. Changes in the mechanical properties of components of the percutaneous lead were measured. After testing, it was concluded that radiation therapy would not impede the operation of the pump or produce deleterious alterations of mechanical properties of the various system components. The patient underwent radiation therapy with a total dose of 2,000 cGy without evident complications. There were no observed effects on the LVAD operation nor any indication of alarms or malfunctions. Subsequently, the patient recovered adequate cardiac function for explant of the LVAD and the recovered components were also analyzed confirming the absence of alterations in material properties that would endanger patient safety.