Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38751322

RESUMO

BACKGROUND: Understanding the characteristics of multiparametric MRI (mpMRI) in patients from different racial/ethnic backgrounds is important for reducing the observed gaps in clinical outcomes. PURPOSE: To investigate the diagnostic performance of mpMRI and quantitative MRI parameters of prostate cancer (PCa) in African American (AA) and matched White (W) men. STUDY TYPE: Retrospective. SUBJECTS: One hundred twenty-nine patients (43 AA, 86 W) with histologically proven PCa who underwent mpMRI before radical prostatectomy. FIELD STRENGTH/SEQUENCE: 3.0 T, T2-weighted turbo spin echo imaging, a single-shot spin-echo EPI sequence diffusion-weighted imaging, and a gradient echo sequence dynamic contrast-enhanced MRI with an ultrafast 3D spoiled gradient-echo sequence. ASSESSMENT: The diagnostic performance of mpMRI in AA and W men was assessed using detection rates (DRs) and positive predictive values (PPVs) in zones defined by the PI-RADS v2.1 prostate sector map. Quantitative MRI parameters, including Ktrans and ve of clinically significant (cs) PCa (Gleason score ≥ 7) tumors were compared between AA and W sub-cohorts after matching age, prostate-specific antigen (PSA), and prostate volume. STATISTICAL TESTS: Weighted Pearson's chi-square and Mann-Whitney U tests with a statistically significant level of 0.05 were used to examine differences in DR and PPV and to compare parameters between AA and matched W men, respectively. RESULTS: A total number of 264 PCa lesions were identified in the study cohort. The PPVs in the peripheral zone (PZ) and posterior prostate of mpMRI for csPCa lesions were significantly higher in AA men than in matched W men (87.8% vs. 68.1% in PZ, and 89.3% vs. 69.6% in posterior prostate). The Ktrans of index csPCa lesions in AA men was significantly higher than in W men (0.25 ± 0.12 vs. 0.20 ± 0.08 min-1; P < 0.01). DATA CONCLUSION: This study demonstrated race-related differences in the diagnostic performances and quantitative MRI measures of csPCa that were not reflected in age, PSA, and prostate volume. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.

2.
AMIA Jt Summits Transl Sci Proc ; 2024: 314-323, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38827101

RESUMO

The process of patients waiting for diagnostic examinations after an abnormal screening mammogram is inefficient and anxiety-inducing. Artificial intelligence (AI)-aided interpretation of screening mammography could reduce the number of recalls after screening. We proposed a same-day diagnostic workup to alleviate patient anxiety by employing an AI-aided interpretation to reduce unnecessary diagnostic testing after an abnormal screening mammogram. However, the potential unintended consequences of introducing this workflow in a high-volume breast imaging center are unknown. Using discrete event simulation, we observed that implementing the AI-aided screening mammogram interpretation and same-day diagnostic workflow would reduce daily patient volume by 4%, increase the time a patient would be at the clinic by 24%, and increase waiting times by 13-31%. We discuss how changing the hours of operation and introducing new imaging equipment and personnel may alleviate these negative impacts.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38818084

RESUMO

The aim of this pilot study is to evaluate and compare the quality of the genomics and proteomics data obtained from paired Formalin Fixed Paraffin Embedded (FFPE) and frozen (FF) tissue percutaneous core biopsies of Liver Imaging Reporting and Data System 5 (LIRADS 5) hepatocellular carcinoma (HCC) of varying histological grades. The preliminary data identified differentially expressed proteins and genes in poor, moderate and well differentiated HCC biopsies, with a greater efficacy in fresh frozen samples. The data offered valuable insights into the characteristics and suitability of samples for future studies.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38645463

RESUMO

Purpose: To rule out hemorrhage, non-contrast CT (NCCT) scans are used for early evaluation of patients with suspected stroke. Recently, artificial intelligence tools have been developed to assist with determining eligibility for reperfusion therapies by automating measurement of the Alberta Stroke Program Early CT Score (ASPECTS), a 10-point scale with > 7 or ≤ 7 being a threshold for change in functional outcome prediction and higher chance of symptomatic hemorrhage, and hypodense volume. The purpose of this work was to investigate the effects of CT reconstruction kernel and slice thickness on ASPECTS and hypodense volume. Methods: The NCCT series image data of 87 patients imaged with a CT stroke protocol at our institution were reconstructed with 3 kernels (H10s-smooth, H40s-medium, H70h-sharp) and 2 slice thicknesses (1.5mm and 5mm) to create a reference condition (H40s/5mm) and 5 non-reference conditions. Each reconstruction for each patient was analyzed with the Brainomix e-Stroke software (Brainomix, Oxford, England) which yields an ASPECTS value and measure of total hypodense volume (mL). Results: An ASPECTS value was returned for 74 of 87 cases in the reference condition (13 failures). ASPECTS in non-reference conditions changed from that measured in the reference condition for 59 cases, 7 of which changed above or below the clinical threshold of 7 for 3 non-reference conditions. ANOVA tests were performed to compare the differences in protocols, Dunnett's post-hoc tests were performed after ANOVA, and a significance level of p < 0.05 was defined. There was no significant effect of kernel (p = 0.91), a significant effect of slice thickness (p < 0.01) and no significant interaction between these factors (p = 0.91). Post-hoc tests indicated no significant difference between ASPECTS estimated in the reference and any non-reference conditions. There was a significant effect of kernel (p < 0.01) and slice thickness (p < 0.01) on hypodense volume, however there was no significant interaction between these factors (p = 0.79). Post-hoc tests indicated significantly different hypodense volume measurements for H10s/1.5mm (p = 0.03), H40s/1.5mm (p < 0.01), H70h/5mm (p < 0.01). No significant difference was found in hypodense volume measured in the H10s/5mm condition (p = 0.96). Conclusion: Automated ASPECTS and hypodense volume measurements can be significantly impacted by reconstruction kernel and slice thickness.

5.
J Am Coll Radiol ; 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38789066

RESUMO

With promising artificial intelligence (AI) algorithms receiving FDA clearance, the potential impact of these models on clinical outcomes must be evaluated locally before their integration into routine workflows. Robust validation infrastructures are pivotal to inspecting the accuracy and generalizability of these deep learning algorithms to ensure both patient safety and health equity. Protected health information concerns, intellectual property rights, and diverse requirements of models impede the development of rigorous external validation infrastructures. The authors propose various suggestions for addressing the challenges associated with the development of efficient, customizable, and cost-effective infrastructures for the external validation of AI models at large medical centers and institutions. The authors present comprehensive steps to establish an AI inferencing infrastructure outside clinical systems to examine the local performance of AI algorithms before health practice or systemwide implementation and promote an evidence-based approach for adopting AI models that can enhance radiology workflows and improve patient outcomes.

6.
Med Image Comput Comput Assist Interv ; 14226: 413-422, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38737498

RESUMO

Mitigating the effects of image appearance due to variations in computed tomography (CT) acquisition and reconstruction parameters is a challenging inverse problem. We present CTFlow, a normalizing flows-based method for harmonizing CT scans acquired and reconstructed using different doses and kernels to a target scan. Unlike existing state-of-the-art image harmonization approaches that only generate a single output, flow-based methods learn the explicit conditional density and output the entire spectrum of plausible reconstruction, reflecting the underlying uncertainty of the problem. We demonstrate how normalizing flows reduces variability in image quality and the performance of a machine learning algorithm for lung nodule detection. We evaluate the performance of CTFlow by 1) comparing it with other techniques on a denoising task using the AAPM-Mayo Clinical Low-Dose CT Grand Challenge dataset, and 2) demonstrating consistency in nodule detection performance across 186 real-world low-dose CT chest scans acquired at our institution. CTFlow performs better in the denoising task for both peak signal-to-noise ratio and perceptual quality metrics. Moreover, CTFlow produces more consistent predictions across all dose and kernel conditions than generative adversarial network (GAN)-based image harmonization on a lung nodule detection task. The code is available at https://github.com/hsu-lab/ctflow.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA