Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Paediatr Anaesth ; 34(11): 1146-1153, 2024 11.
Artigo em Inglês | MEDLINE | ID: mdl-38980197

RESUMO

INTRODUCTION: This study aimed to assess the impact of positive-end-expiratory pressure (PEEP) on the non-hypoxic apnea time in infants during anesthesia induction with an inspired oxygen fraction of 0.8. METHODS: This age stratified randomized controlled trial included patients under 1 year of age. Preoxygenation was performed using an inspired oxygen fraction of 0.8 for 2 min. Inspired oxygen fraction of 0.8 was administered via a face mask with volume-controlled ventilation at a tidal volume of 6 mL.kg-1, with or without 7 cmH2O of PEEP. Tracheal intubation was performed after 3 min of ventilation; however, it was disconnected from the breathing circuit. Ventilation was resumed once the pulse oximetry readings reached 95%. The primary outcome was the non-hypoxic apnea time, defined as the time from the cessation of ventilation to achieving a pulse oximeter reading of 95%. The secondary outcome measures included the degree of atelectasis assessed by ultrasonography and the presence of gastric air insufflation. RESULTS: Eighty-four patients were included in the final analysis. In the positive end-expiratory pressure group, the atelectasis score decreased (17.0 vs. 31.5, p < .001; mean difference and 95% CI of 11.6, 7.5-15.6), while the non-hypoxic apnea time increased (80.1 s vs. 70.6 s, p = .005; mean difference and 95% CI of -9.4, -16.0 to -2.9), compared to the zero end-expiratory pressure group, among infants who are 6 months old or younger, not in those aged older than 6 months. DISCUSSION: The application of positive end-expiratory pressure reduced the incidence of atelectasis and extended the non-hypoxic apnea time in infants who are 6 months old or younger. However, it did not affect the incidence of atelectasis nor the non-hypoxic apnea time in patients aged older than 6 months.


Assuntos
Apneia , Respiração com Pressão Positiva , Atelectasia Pulmonar , Humanos , Respiração com Pressão Positiva/métodos , Atelectasia Pulmonar/prevenção & controle , Atelectasia Pulmonar/etiologia , Lactente , Masculino , Feminino , Recém-Nascido , Anestesia/métodos , Oximetria/métodos
2.
Paediatr Anaesth ; 34(11): 1154-1161, 2024 11.
Artigo em Inglês | MEDLINE | ID: mdl-39193638

RESUMO

BACKGROUND: High-flow nasal oxygenation is reported to prolong duration of apnea while maintaining adequate oxygen saturation with the mouth closed. Also, buccal oxygenation is known to have similar effects in obese adults. We compared the effect of these two methods on prolongation of acceptable apnea time in pediatric patients with their mouth open. METHODS: Thirty-eight patients, aged 0-10 years were randomly allocated to either the high-flow nasal oxygenation group (n = 17) or the buccal oxygenation group (n = 21). After induction of anesthesia including neuromuscular blockade, manual ventilation was initiated until the expiratory oxygen concentration reached 90%. Subsequently, ventilation was paused, and the patient's head was extended, and mouth was opened. The HFNO group received 2 L·min-1·kg-1 of oxygen, and the BO group received 0.5 L·min-1·kg-1 of oxygen. We set a target apnea time according to previous literature. When the apnea time reached the target, we defined the case as "success" in prolongation of safe apnea time and resumed ventilation. When the pulse oximetry decreased to 92% before the target apnea time, it was recorded as "failure" and rescue ventilation was given. RESULTS: The success rate of safe apnea prolongation was 100% in the high-flow nasal oxygenation group compared to 76% in the buccal oxygenation group (p = .04). Oxygen reserve index, end-tidal or transcutaneous carbon dioxide partial pressure, and pulse oximetry did not differ between groups. CONCLUSION: High-flow nasal oxygenation is effective in maintaining appropriate arterial oxygen saturation during apnea even in children with their mouth open and is superior to buccal oxygenation. Buccal oxygenation may be a good alternative when high-flow nasal oxygenation is not available.


Assuntos
Apneia , Oxigenoterapia , Humanos , Apneia/terapia , Masculino , Feminino , Pré-Escolar , Oxigenoterapia/métodos , Criança , Lactente , Administração Bucal , Administração Intranasal , Saturação de Oxigênio/fisiologia , Oxigênio/sangue , Boca , Recém-Nascido , Oximetria/métodos
3.
Paediatr Anaesth ; 34(8): 758-767, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38693633

RESUMO

AIMS: This study determined the optimal positive end-expiratory pressure levels in infants in supine and prone positions under general anesthesia using electrical impedance tomography (EIT). METHODS: This prospective observational single-centre study included infants scheduled for surgery in the prone position. An electrical impedance tomography sensor was applied after inducing general anesthesia. The optimal positive end-expiratory pressure in the supine position was determined in a decremental trial based on EIT and compliance. Subsequently, the patient's position was changed to prone. Electrical impedance tomography parameters, including global inhomogeneity index, regional ventilation delay, opening pressure, the centre of ventilation, and pendelluft volume, were continuously obtained up to 1 h after prone positioning. The optimal positive end-expiratory pressure in the prone position was similarly determined. RESULTS: Data from 30 infants were analyzed. The mean value of electrical impedance tomography-based optimal positive end-expiratory pressure in the prone position was significantly higher than that in the supine position [10.9 (1.6) cmH2O and 6.1 (0.9) cmH2O, respectively (p < .001)]. Significant differences were observed between electrical impedance tomography- and compliance-based optimal positive end-expiratory pressure. Peak and mean airway, plateau, and driving pressures increased 1 h after prone positioning compared with those in the supine position. In addition, the centre of ventilation for balance in ventilation between the ventral and dorsal regions improved. CONCLUSION: The prone position required higher positive end-expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end-expiratory pressure, which needs to be individualized.


Assuntos
Anestesia Geral , Impedância Elétrica , Respiração com Pressão Positiva , Tomografia , Humanos , Respiração com Pressão Positiva/métodos , Anestesia Geral/métodos , Decúbito Ventral/fisiologia , Decúbito Dorsal , Lactente , Estudos Prospectivos , Masculino , Feminino , Tomografia/métodos , Recém-Nascido
4.
Paediatr Anaesth ; 34(1): 35-41, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37587734

RESUMO

BACKGROUND: Optimal pain management after insertion of a central venous catheter in children remains unclear. AIM: This study aimed to evaluate the effects of a selective supraclavicular nerve block on postoperative analgesia in pediatric patients undergoing hickman catheter or chemoport insertion. METHODS: Fifty patients aged 3-18 years scheduled for elective Hickman or chemoport insertion were randomized into two groups of 25 each: one group received an ultrasound-guided selective supraclavicular nerve block with 0.1 mL/kg of 0.5% ropivacaine (SSCNB group), and the other group did not receive a nerve block (control group). The primary outcome was the postoperative Wong-Baker Faces Pain Rating Scale score measured between 10 and 30 min after surgery. Secondary outcomes included pain scores at 1, 3, and 24 h after the surgery, block-related complications, length of stay in the postanesthesia care unit, postoperative analgesic consumption, and time to first analgesic use 24 h after surgery. RESULTS: The worst pain score within 30 min in the recovery room was significantly lower in the SSCNB group compared to the control group (6 [5-7] vs. 3 [2-4]; median difference, -3; 95% CI, -4 to -1; p < .001). Pain scores at 1, 3, and 24 h after surgery were also significantly lower in the SSCNB group. The need for both opioid and non-opioid analgesics in the postoperative period was significantly lower in the SSCNB group (36.0% vs. 0%; p = .002 and 44.0% vs. 16.0%; mean difference, -28%; 95% CI, -56 to 0.19; p = .033, respectively), while other secondary outcomes were not significantly different between the two groups. CONCLUSIONS: Ultrasound-guided SSCNB is an effective method for managing postoperative pain in children undergoing Hickman catheter or chemoport insertion, reducing the need for analgesics within 24 h after surgery.


Assuntos
Bloqueio do Plexo Braquial , Cateteres Venosos Centrais , Humanos , Criança , Anestésicos Locais/uso terapêutico , Cateteres Venosos Centrais/efeitos adversos , Ultrassonografia de Intervenção/métodos , Dor Pós-Operatória/tratamento farmacológico , Dor Pós-Operatória/etiologia , Bloqueio do Plexo Braquial/efeitos adversos , Analgésicos , Analgésicos Opioides
5.
Eur J Anaesthesiol ; 41(9): 687-694, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39087414

RESUMO

BACKGROUND: Hypoxaemia occurs frequently during paediatric laryngeal microsurgery. OBJECTIVE: The oxygen reserve index is a noninvasive and continuous parameter to assess PaO2 levels in the range of 100 to 200 mmHg. It ranges from 0 to 1.0. We investigated whether monitoring the oxygen reserve index can reduce the incidence of SpO2 90% or less. DESIGN: Randomised controlled trial. SETTING: A tertiary care paediatric hospital. PARTICIPANTS: Paediatric patients aged 18 years or less scheduled to undergo laryngeal microsurgery. INTERVENTION: The patients were randomly allocated to the oxygen reserve index or control groups, and stratified based on the presence of a tracheostomy tube. Rescue intervention was performed when the oxygen reserve index was 0.2 or less and the SpO2 was 94% or less in the oxygen reserve index and control groups, respectively. MAIN OUTCOME MEASURE: The primary outcome was the incidence of SpO2 90% or less during the surgery. RESULTS: Data from 88 patients were analysed. The incidence of SpO2 ≤ 90% did not differ between the oxygen reserve index and control groups [P = 0.114; 11/44, 25% vs. 18/44, 40.9%; relative risk: 1.27; and 95% confidence interval (CI): 0.94 to 1.72]. Among the 128 rescue interventions, SpO2 ≤ 90% event developed in 18 out of 75 events (24%) and 42 out of 53 events (79.2%) in the oxygen reserve index and control groups, respectively (P < 0.001; difference: 55.2%; and 95% CI 38.5 to 67.2%). The number of SpO2 ≤ 90% events per patient in the oxygen reserve index group (median 0, maximum 3) was less than that in the control group (median 0, maximum 8, P = 0.031). CONCLUSION: Additional monitoring of the oxygen reserve index, with a target value of greater than 0.2 during paediatric airway surgery, alongside peripheral oxygen saturation, did not reduce the incidence of SpO2 ≤ 90%.


Assuntos
Hipóxia , Saturação de Oxigênio , Humanos , Masculino , Feminino , Hipóxia/prevenção & controle , Hipóxia/sangue , Hipóxia/etiologia , Pré-Escolar , Oxigênio/sangue , Criança , Lactente , Microcirurgia/métodos , Laringe , Oximetria/métodos , Monitorização Intraoperatória/métodos , Adolescente
6.
Eur J Anaesthesiol ; 41(9): 649-656, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38832435

RESUMO

BACKGROUND: The potential benefits of Analgesia Nociception Index guided intra-operative analgesia on intra-operative opioid consumption remains to be demonstrated in paediatric anaesthesia. OBJECTIVES: This study aimed to explore the effects of Analgesia Nociception Index guided analgesia on sufentanil consumption during anaesthesia and postoperative pain scores in paediatric patients with moyamoya disease. DESIGN: A prospective randomised controlled study. SETTING: Seoul National University Children's Hospital, Seoul, Republic of Korea. PATIENTS: A total of 40 children scheduled for encephaloduroarteriosynangiosis. MAIN OUTCOME MEASURES: The primary outcome was total intra-operative sufentanil consumption, and the secondary outcomes included postoperative pain scores and incidence of opioid-related adverse events. RESULTS: The Analgesia Nociception Index group showed lower intra-operative sufentanil consumption (in µg kg -1  h -1 ) compared with the Standard group (0.30 ±â€Š0.12 and 0.39 ±â€Š0.17, respectively; mean difference, -0.09; 95% confidence interval, -0.19 to 0.00; P  = 0.049). Postoperatively, compared with the Standard group, the Analgesia Nociception Index group reported lower median pain scores at 18 and 24 h and maximum pain within 24 h (1 [0 to 2] vs. 3 [2 to 5]; P  = 0.004, 1 [0 to 2] vs. 3 [1 to 4]; P  = 0.041, and 4 [3 to 5] vs. 5 [4 to 7]; P  = 0.045, respectively), with fewer patients experiencing nausea (3 [15%] vs. 10 [50%], P  = 0.043). CONCLUSION: The Analgesia Nociception Index guided analgesic protocol can reduce intra-operative sufentanil consumption and postoperative pain within 24 h with fewer nausea symptoms in paediatric patients with moyamoya disease who undergo encephaloduroarteriosynangiosis. TRIAL REGISTRATION NUMBER: NCT05672212.


Assuntos
Analgésicos Opioides , Doença de Moyamoya , Nociceptividade , Dor Pós-Operatória , Sufentanil , Humanos , Doença de Moyamoya/cirurgia , Feminino , Masculino , Criança , Estudos Prospectivos , Dor Pós-Operatória/prevenção & controle , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Sufentanil/administração & dosagem , Nociceptividade/efeitos dos fármacos , Analgésicos Opioides/administração & dosagem , Pré-Escolar , Analgesia/métodos , Medição da Dor/métodos , Adolescente , Resultado do Tratamento
7.
Eur J Anaesthesiol ; 41(9): 641-648, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38884417

RESUMO

BACKGROUND: The association between the concentration of atmospheric particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia in children receiving general anaesthesia is unclear. OBJECTIVE: To investigate the association between the exposure to particulate matter on the day of surgery and the occurrence of intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% for more than 1 min, in children. DESIGN: Retrospective study. SETTING: Single-centre. PARTICIPANTS: Children aged 18 years or younger who received general anaesthesia between January 2019 and October 2020. INTERVENTION: Information on daily levels of particulate matter with a diameter 10 µm or less and 2.5 µm or less measured within a neighbourhood corresponding to the area defined by the hospital's zip code was obtained from publicly available air-quality data. MAIN OUTCOME MEASURES: The primary outcome was intra-operative hypoxaemia, defined as a pulse oximetry oxygen saturation of less than 90% lasting for more than 1 min, manually verified by anaesthesiologists using vital sign registry data extracted at 2 s intervals. RESULTS: Of the patients finally analysed, 3.85% (489/13 175) experienced intra-operative hypoxaemia. Higher levels of particulate matter 10 µm or less in diameter (≥81 µg m -3 , 17/275, 6.2%) were associated with an increased occurrence of intra-operative hypoxaemia compared with lower particulate matter concentrations [<81 µg m -3 , 472/12 900, 3.7%; adjusted odds ratio, 1.71; 95% confidence interval (CI), 1.04 to 2.83; P  = 0.035]. CONCLUSION: The level of particulate matter on the day of surgery pose a risk of intra-operative hypoxaemia in children receiving general anaesthesia. If the concentrations of particulate matter 10 µm or less in diameter on the day of surgery are high, children receiving general anaesthesia should be managed with increased caution.


Assuntos
Anestesia Geral , Hipóxia , Material Particulado , Humanos , Anestesia Geral/efeitos adversos , Estudos Retrospectivos , Material Particulado/efeitos adversos , Hipóxia/epidemiologia , Hipóxia/etiologia , Hipóxia/induzido quimicamente , Hipóxia/sangue , Masculino , Feminino , Criança , Pré-Escolar , Lactente , República da Coreia/epidemiologia , Adolescente , Oximetria , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/induzido quimicamente , Recém-Nascido , Saturação de Oxigênio
8.
Eur J Anaesthesiol ; 41(7): 522-529, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38517311

RESUMO

BACKGROUND: The effectiveness of head mounted real-time ultrasound displays (hereafter referred to as 'smart glasses') in improving hand-eye coordination in less experienced individuals, such as trainees in anaesthesia, is unclear. OBJECTIVES: To compare the first-attempt success rate of smart glasses-assisted ultrasound-guided paediatric radial artery catheterisation with conventional ultrasound guided catheterisation performed by anaesthesiology trainees. DESIGN: Prospective randomised controlled trial. SETTINGS: Tertiary university hospital from September 2021 to February 2023. PATIENTS: One hundred and twenty-two paediatric patients (age <7 years, weight ≥3 kg) who required radial artery cannulation during general anaesthesia. INTERVENTIONS: The participants were randomly assigned to either the ultrasound screen group (control) or the smart glasses group prior to radial artery catheterisation. MAIN OUTCOME MEASURES: The primary outcome was the first attempt success rate. Secondary outcomes included the number of attempts, use of transfixion technique, overall complication rate, and clinical anaesthesiology (CA) year of the operators. RESULTS: A total of 119 paediatric patients were included in the analysis. The smart glasses group exhibited higher first-attempt success rate than did the control group (89.8% [53/59] vs. 71.7% [43/60]; P  = 0.023; odds ratio (OR) 3.49; (95% confidence interval (CI) 1.27-9.6). The overall number of attempts [median, 1; interquartile range (IQR), 1-1; range, 1-3 vs. median, 1; IQR, 1-2; range, 1-4; P   =  0.006], use of transfixion technique (12/59 [20.3%] vs. 28/60 [46.7%]; P  = 0.002), and overall complication rate (6.8% [4/59] vs. 30.0% [18/60]; P  = 0.002) were lower in the smart glasses group than in the control group. However, among paediatric anaesthesiology fellows (CA 5 years), the first- (89.3% [25/28] vs. 80.8% [21/26]; P  = 0.619) and second-attempt success rates (96.4% [27/28] vs. 80.8% [21/26]; P  = 0.163) did not differ between the two groups. CONCLUSIONS: Smart glasses-assisted ultrasound guided radial artery catheterisation improved the first attempt success rate among anaesthesiology trainees, reducing the number of attempts and overall complication rates in small paediatric patients. Smart glasses were more effective for anaesthesia residents (CA 2-4 years) but were not effective for paediatric anaesthesiology fellows (CA 5 years). TRIAL REGISTRATION: ClinicalTrials.gov (NCT05030649) ( https://classic.clinicaltrials.gov/ct2/show/NCT05030649 ).


Assuntos
Anestesiologia , Cateterismo Periférico , Artéria Radial , Ultrassonografia de Intervenção , Humanos , Artéria Radial/diagnóstico por imagem , Feminino , Masculino , Estudos Prospectivos , Ultrassonografia de Intervenção/métodos , Cateterismo Periférico/métodos , Anestesiologia/educação , Pré-Escolar , Criança , Lactente , Óculos Inteligentes , Anestesia Geral , Competência Clínica , Cabeça
9.
Cardiol Young ; 34(4): 914-918, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37981864

RESUMO

BACKGROUNDS AND OBJECTIVES: The "Fast track" protocol is an early extubation strategy to reduce ventilator-associated complications and induce early recovery after open-heart surgery. This study compared clinical outcomes between operating room extubation and ICU extubation after open-heart surgery in patients with CHD. METHODS: We retrospectively reviewed 215 patients who underwent open-heart surgery for CHDs under the scheduled "Fast track" protocol between September 2016 and April 2022. The clinical endpoints were post-operative complications, including bleeding, respiratory and neurological complications, and hospital/ICU stays. RESULTS: The patients were divided into operating room extubation (group O, n = 124) and ICU extubation (group I, n=91) groups. The most frequently performed procedures were patch closures of the atrial septal (107/215, 49.8%) and ventricular septal (89/215, 41.4%) defects. There were no significant differences in major post-operative complications or ICU and hospital stay duration between the two groups; however, patients in group I showed longer mechanical ventilatory support (0.0 min vs. 59.0 min (interquartile range: 17.0-169.0), p < 0.001). Patients in Group O showed higher initial lactate levels (3.2 ± 1.7 mg/dL versus 2.5 ± 2.0 mg/dL, p = 0.007) and more frequently used additional sedatives and opioid analgesics (33.1% versus 19.8%, p = 0.031). CONCLUSIONS: Extubation in the operating room was not beneficial for patients during post-operative ICU or hospital stay. Early extubation in the ICU resulted in more stable hemodynamics in the immediate post-operative period and required less use of sedatives and analgesics.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Salas Cirúrgicas , Humanos , Estudos Retrospectivos , Extubação/métodos , Hipnóticos e Sedativos , Unidades de Terapia Intensiva , Tempo de Internação
10.
BMC Oral Health ; 24(1): 327, 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38475776

RESUMO

BACKGROUND: Understanding when and why endodontic treatments fail could help clinicians make prognoses and thus improve treatment outcomes. This study was aimed to assess potential predictors of early endodontic treatment failure. We explored factors contributing to the failure of initial root canal treatment were explored, with a specific emphasis on evaluating the influence of the time elapsed since the initial treatment. METHODS: This retrospective cohort study enrolled 1262 patients who sought endodontic treatment at our department and 175 patients were included for analysis. Potential causes of endodontic treatment failure were investigated, such as inadequate obturation quality, inadequate coronal status, the presence of additional untreated canals, anatomical complexity, instrument separation, iatrogenic perforation, cracks, and endodontic-periodontal lesions. The patients were divided into "short-term" and "long-term" groups depending on the time that had passed since the initial treatment (i.e., < 5 and > 10 years, respectively). The causes of failure in the short-term and long-term group were analyzed and compared using logistic regression analyses. Subgroup analysis was performed according to the number of years since the initial treatment in the short-term group to further investigate the association between the time and cause of failure (i.e., < 1, 2, 3, and 4 years, respectively). RESULTS: Untreated additional canals were present in 21.7% of all cases, and in 36.9 and 6.4% of cases in the short-term and long-term groups, respectively. Multivariable analysis showed that the presence of untreated additional canals was significantly associated with short-term compared to long-term failure. Untreated additional canals were also associated with endodontic failure within 1, 2, 3, and 4 years. CONCLUSIONS: The presence of untreated additional canals was a predictor of endodontic failure within 5 years following initial root canal treatment. To optimize long-term prognosis, it is important to detect and treat all root canals during the initial treatment.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Humanos , Estudos Retrospectivos , Tratamento do Canal Radicular/efeitos adversos , Falha de Tratamento , Resultado do Tratamento
11.
Anesth Analg ; 136(6): 1067-1074, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36727868

RESUMO

BACKGROUND: Perioperative respiratory adverse events are common in children. We aimed to evaluate the effect of the transdermal ß-2 agonist, tulobuterol, compared with that of placebo on the incidence of perioperative respiratory adverse events in pediatric patients undergoing tonsillectomy. METHODS: In this triple-blinded (patient, anesthesia provider, and outcome assessor) randomized controlled trial, 188 patients were randomly allocated to receive tulobuterol or a placebo. The tulobuterol groups received a tulobuterol patch (1 mg) masked with a bandage, whereas the placebo only received the bandage. The assigned bandage was applied to the patients 8 to 10 hours before the surgery. The primary outcome was the occurrence of any perioperative respiratory adverse events: oxygen desaturation <95%, airway obstruction, laryngospasm, bronchospasm, severe coughing, or stridor. The outcomes were evaluated using the average relative effect test, which estimates the effect of individual components of a composite outcome and then averages effects across components. RESULTS: A total of 88 and 94 patients who received tulobuterol and placebo, respectively, were analyzed. The incidence of any perioperative respiratory adverse event was lower with tulobuterol (n = 13/88; 14.7%) than that with the placebo (n = 40/94; 42.5%), with an estimated average relative risk (95% confidence interval) across components of 0.35 (0.20-0.60; P < .001). The symptoms of airway obstruction were lower with tulobuterol (n = 8/88; 9.0%) than that with the placebo (n = 32/94; 34.0%), with relative risk (95% CI) of 0.31 (0.17-0.56; P < .001). The occurrence of severe coughing was lower with tulobuterol (n = 1/88; 1.1%) than that with the placebo (n = 8/94; 8.5%), with relative risk (95% CI) of 0.15 (0.03-0.68; P = .014). CONCLUSIONS: In preschool children undergoing tonsillectomy, the preoperative application of a tulobuterol patch could decrease the occurrence of perioperative respiratory adverse events. Further studies are needed to elucidate the effect of the tulobuterol patch in a broad spectrum of pediatric anesthesia.


Assuntos
Obstrução das Vias Respiratórias , Tonsilectomia , Pré-Escolar , Humanos , Criança , Tonsilectomia/efeitos adversos , Terbutalina/efeitos adversos , Tosse/induzido quimicamente , Tosse/epidemiologia , Tosse/prevenção & controle
12.
Can J Anaesth ; 70(12): 1957-1969, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37919629

RESUMO

PURPOSE: Increased portal venous flow pulsatility is associated with major complications after adult cardiac surgery. Nevertheless, no data are available for pediatric patients with congenital heart disease. We hypothesized that Doppler parameters including portal flow pulsatility could be associated with postoperative outcomes in children undergoing various cardiac surgeries. METHODS: We conducted a prospective observational cohort study in children undergoing congenital cardiac surgery. We obtained postoperative portal, splenic, and hepatic venous Doppler data and perioperative clinical data including major postoperative complications. Portal and splenic venous flow pulsatility were calculated. We evaluated the association between venous Doppler parameters and adverse outcomes. The primary objective was to determine whether postoperative portal flow pulsatility could indicate major complications following congenital heart surgery. RESULTS: In this study, we enrolled 389 children, 74 of whom experienced major postoperative complications. The mean (standard deviation) portal pulsatility (44 [30]% vs 25 [14]%; 95% confidence interval [CI] for mean difference, 12 to 26; P < 0.001] and splenic pulsatility indices (41 [30]% vs 26 [16]%; 95% CI, 7 to 23; P < 0.001) were significantly higher in children with postoperative complications than in those without complications. The portal pulsatility index was able to help identify postoperative complications in biventricular patients and univentricular patients receiving bidirectional cavopulmonary shunt whereas it did not in other univentricular patients. An increased postoperative portal pulsatility index was significantly associated with major complications after pediatric cardiac surgery (odds ratio, 1.40; 95% CI, 1.29 to 1.91; P < 0.001). CONCLUSIONS: Higher portal venous pulsatility is associated with major postoperative complications in children undergoing cardiac surgery. Nevertheless, more data are needed to conclude the efficacy of portal venous pulsatility in patients with univentricular physiology. STUDY REGISTRATION: ClinicalTrials.gov (NCT03990779); registered 19 June 2019.


RéSUMé: OBJECTIF: L'augmentation de la pulsatilité du flux de la veine porte est associée à des complications majeures après une chirurgie cardiaque chez l'adulte. Néanmoins, aucune donnée n'est disponible pour la patientèle pédiatrique atteinte de cardiopathie congénitale. Nous avons émis l'hypothèse que les paramètres Doppler, y compris la pulsatilité du flux de la veine porte, pourraient être associés aux devenirs postopératoires des enfants bénéficiant de diverses chirurgies cardiaques. MéTHODE: Nous avons réalisé une étude de cohorte observationnelle prospective portant sur des enfants bénéficiant d'une chirurgie cardiaque congénitale. Nous avons obtenu des données Doppler des veines porte, spléniques et hépatiques postopératoires ainsi que des données cliniques périopératoires, y compris les complications postopératoires majeures. La pulsatilité du flux des veines porte et spléniques a été calculée. Nous avons évalué l'association entre les paramètres Doppler veineux et les issues indésirables. L'objectif principal était de déterminer si la pulsatilité du flux postopératoire de la veine porte pouvait constituer un indicateur des complications majeures après une chirurgie cardiaque congénitale. RéSULTATS: Dans cette étude, nous avons recruté 389 enfants, dont 74 ont présenté des complications postopératoires majeures. La pulsatilité moyenne de la veine porte (écart type) (44 [30] % vs 25 [14] %; intervalle de confiance [IC] à 95 % pour la différence moyenne, 12 à 26; P < 0,001] et les indices de pulsatilité splénique (41 [30] % vs 26 [16] %; IC 95 %, 7 à 23; P < 0,001) étaient significativement plus élevés chez les enfants présentant des complications postopératoires que chez les enfants sans complications. L'indice de pulsatilité de la veine porte a permis d'identifier les complications postopératoires chez les patient·es biventriculaires et les patient·es univentriculaires recevant une anastomose cavo-pulmonaire bidirectionnelle (procédure de Glenn), alors que ce n'était pas le cas chez les autres patient·es univentriculaires. Une augmentation postopératoire de l'indice de pulsatilité de la veine porte était significativement associée à des complications majeures après une chirurgie cardiaque pédiatrique (rapport de cotes, 1,40; IC 95 %, 1,29 à 1,91; P < 0,001). CONCLUSION: Une pulsatilité plus élevée de la veine porte est associée à des complications postopératoires majeures chez les enfants bénéficiant d'une chirurgie cardiaque. Néanmoins, davantage de données sont nécessaires pour conclure à l'efficacité de la pulsatilité de la veine porte chez les patient·es présentant une physiologie univentriculaire. ENREGISTREMENT DE L'éTUDE: ClinicalTrials.gov (NCT03990779); enregistrée le 19 juin 2019.


Assuntos
Cardiopatias Congênitas , Veia Porta , Criança , Humanos , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Veia Porta/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Ultrassonografia Doppler
13.
J Cardiothorac Vasc Anesth ; 37(8): 1456-1468, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37183119

RESUMO

OBJECTIVE: Little is known about changes in portal, splenic, and hepatic vein flow patterns in children undergoing congenital heart surgery. This study aimed to determine the characteristics of portal, splenic, and hepatic vein flow patterns using ultrasonography in children undergoing cardiac surgery. DESIGN: Single-center, prospective observational study. SETTING: Tertiary children's hospital, operating room. PARTICIPANTS: Children undergoing cardiac surgery. MEASUREMENT AND MAIN RESULTS: The authors obtained ultrasound data from the heart, inferior vena cava, portal, splenic, and hepatic veins before and after surgeries. In the biventricular group, which included children with atrial and ventricular septal defects and pulmonary stenosis (n = 246), the portal pulsatility index decreased from 38.7% to 25.6% (p < 0.001) after surgery. The preoperative portal pulsatility index was significantly higher in patients with pulmonary hypertension (43.3% v 27.4%; p < 0.001). In the single-ventricle group (n = 77), maximum portal vein flow velocities of Fontan patients were significantly lower (13.5 cm/s) compared with that of patients with modified Blalock-Taussig shunt (19.7 cm/s; p = 0.035) or bidirectional cavopulmonary shunt (23.1 cm/s; p < 0.001). The cardiac index was inversely correlated with the portal pulsatility index in the bidirectional cavopulmonary shunt and Fontan circulation. (ß = -5.693, r2 = 0.473; p = 0.001) The portal pulsatility index was correlated with splenic venous pulsatility and hepatic venous atrial reverse flow velocity in biventricular and single-ventricle groups. CONCLUSIONS: The characteristics of venous Doppler patterns in the portal, splenic, and hepatic veins differed according to congenital heart disease. Further studies are required to determine the association between splanchnic venous Doppler findings and clinical outcomes in this population.


Assuntos
Fibrilação Atrial , Técnica de Fontan , Cardiopatias Congênitas , Humanos , Criança , Veias Hepáticas/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Velocidade do Fluxo Sanguíneo
14.
Paediatr Anaesth ; 33(7): 562-570, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37061868

RESUMO

BACKGROUND: The light reflex, which reflects central nervous system dysfunction, can also be affected by anesthetic agents. AIMS: We evaluated whether these effects differed according to the anesthetic agent in pediatric patients. METHODS: Twenty children aged 3-12 years who were scheduled to undergo elective surgery under general anesthesia were randomly allocated to propofol and sevoflurane groups and underwent pupillometric assessments at five points during anesthesia: T1, after confirming loss of consciousness; T2, after endotracheal intubation; T3, at the time of skin incision; T4, 1 h after skin incision; and T5, before endotracheal extubation. The primary outcome was the Neurological Pupil index at T4, and the secondary outcomes were other pupillometric parameters, including pupil diameter, percentage of change in pupil diameter, dilation velocity, and constriction velocity. RESULTS: At T4, the Neurological Pupil index was significantly lower in the sevoflurane group (median difference, 0.30; 95% CI, 0.00 to 0.70; p = .036). Furthermore, the Neurological Pupil index at all time points was lower in the sevoflurane group. The time-and-group interaction effects on constriction velocity and dilation velocity were significantly different [F(1, 4) = 16.68, p = .002; F(1, 4) = 14.78, p = .008, respectively] but were not different on the Neurological Pupil index, pupil diameter, and percentage of change in pupil diameter. No intergroup differences were observed in the baseline characteristics, the flow rate of remifentanil at each time point, and total infused remifentanil. CONCLUSION: The Neurological Pupil index value in pediatric patients under general anesthesia is affected by the anesthetic agent used; this factor requires consideration in evaluations of the Neurological Pupil index during general anesthesia.


Assuntos
Anestésicos Intravenosos , Propofol , Humanos , Criança , Anestésicos Intravenosos/farmacologia , Remifentanil , Sevoflurano , Propofol/farmacologia , Anestesia Geral , Anestesia Intravenosa
15.
Paediatr Anaesth ; 33(4): 303-311, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36594749

RESUMO

BACKGROUND: Cardiopulmonary bypass can affect the pharmacokinetics of anesthetic agents. AIMS: We aimed to evaluate the pharmacokinetics of dexmedetomidine for infants and small children undergoing cardiac surgery with cardiopulmonary bypass based on population pharmacokinetics. METHODS: We enrolled 30 pediatric cardiac surgical patients in this study. After anesthetic induction with atropine (0.02 mg/kg), thiopental sodium (5 mg/kg), and fentanyl (2-3 µg/kg), we administered 1 µg/kg of dexmedetomidine for 10 min, followed by administration of 0.5 µg/kg of dexmedetomidine per hour during surgery. At the initiation of cardiopulmonary bypass, 1 µg/kg of dexmedetomidine was infused over 5 min. Arterial blood was obtained at predefined time points. A pharmacokinetic model was developed using NONMEM. Theory-based allometric scaling with fixed exponents was applied. Weight, age, post-menstrual age, fat-free mass, whether to implement cardiopulmonary bypass and temperature were explored as covariates. RESULTS: A total of 376 blood samples were obtained from 29 children (age: 20.3 ± 19.3 months, weight: 9.7 ± 4.1 kg). A two-compartment mammillary model with third compartment associated cardiopulmonary bypass procedure best explained the pharmacokinetics of dexmedetomidine. The pharmacokinetic parameter estimates (95% CI) standardized to a 70-kg person were as follows: V1 (L) = 31.6 (17.9-39.5), V2 (L) = 90.1 (44.0-330), Cl (L/min) = 1.08 (0.70-1.25), Q (L/min) = 2.0 (1.05-3.46). Volume for third compartment associated cardiopulmonary bypass procedure (L) = 39.4 (19.3-50.9). Clearance was not influenced by the presence of cardiopulmonary bypass in this model. CONCLUSION: When cardiopulmonary bypass is applied, the plasma concentration of dexmedetomidine decreases due to an increase in the volume of distribution, so a loading dose is required to maintain the previous concentration.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Dexmedetomidina , Lactente , Criança , Humanos , Pré-Escolar , Hipnóticos e Sedativos , Ponte Cardiopulmonar , Fentanila
16.
Paediatr Anaesth ; 33(11): 930-937, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37641455

RESUMO

INTRODUCTION: It is known that pulse pressure variation and systolic pressure variation cannot predict fluid responsiveness in children. In adults, the ability of these dynamic parameters to predict fluid responsiveness is improved by increasing tidal volume. We planned to investigate whether pulse pressure variation or systolic pressure variation can predict fluid responsiveness in children when augmented by increasing tidal volume by conducting a prospective study. METHODS: We enrolled children younger than 7 years who underwent cardiac surgery for atrial septal defect or ventricular septal defect. After sternum closure, pulse pressure variation and systolic pressure variation were continuously recorded while changing the tidal volume to 6, 10, and 14 mL/kg. Fluid loading was done with 10 mL/kg of crystalloids for 10 min, and stroke volume index was measured via transesophageal echocardiography. Children whose stroke volume index increased by more than 15% after the fluid loading were defined as responders to fluid therapy. We set primary outcome as the predictability of pulse pressure variation and systolic pressure variation for fluid responsiveness and measured the area under the curve of receiver operating characteristics curve. RESULTS: Twenty-six children were included, of which 15 were responders. At the tidal volume of 14 mL/kg, the area under the curves of receiver operating characteristics curves of pulse pressure variation and systolic pressure variation were 0.576 (p = .517) and 0.548 (p = .678), respectively. The differences in dynamic parameters between responders and nonresponders were not significant. DISCUSSION: Failure of pulse pressure variation or systolic pressure variation at augmented tidal volume in children may be due to difference in their arterial compliance from those of adults. Large compliance of thoracic wall may be another reason. CONCLUSIONS: Augmented pulse pressure variation or systolic pressure variation due to increased tidal volume cannot predict fluid responsiveness in children after simple cardiac surgery.


Assuntos
Hidratação , Hemodinâmica , Adulto , Humanos , Criança , Estudos Prospectivos , Volume de Ventilação Pulmonar , Pressão Sanguínea , Volume Sistólico , Frequência Cardíaca , Curva ROC , Respiração Artificial
17.
J Korean Med Sci ; 38(47): e349, 2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38050910

RESUMO

BACKGROUND: The perianesthetic morbidity, mortality risk and anesthesia-associated risk after preoperative coronavirus disease 2019 (COVID-19) omicron variant in pediatric patients have not been fully demonstrated. We examined the association between preoperative COVID-19 omicron diagnosis and the incidence of overall perioperative adverse events in pediatric patients who received general anesthesia. METHODS: This retrospective study included patients aged < 18 years who received general anesthesia between February 1 and June 10, 2022, in a single tertiary pediatric hospital. They were divided into two groups; patients in a COVID-19 group were matched to patients in a non-COVID-19 group during the omicron-predominant period in Korea. Data on patient characteristics, anesthesia records, post-anesthesia records, COVID-19-related history, symptoms, and mortality were collected. The primary outcomes were the overall perioperative adverse events, including perioperative respiratory adverse events (PRAEs), escalation of care, and mortality. RESULTS: In total, 992 patients were included in the data analysis (n = 496, COVID-19; n = 496, non-COVID-19) after matching. The overall incidence of perioperative adverse events was significantly higher in the COVID-19 group than in the non-COVID-19 group (odds ratio [OR], 1.92; 95% confidence interval [CI], 1.89-1.94). The difference was significant for PRAEs (OR, 2.00; 95% CI, 1.96-2.02) but not in escalation of care or mortality. The most pronounced difference between the two groups was observed in instances of high peak inspiratory pressure ≥ 25 cmH2O during the intraoperative period (OR, 11.0; 95% CI, 10.5-11.4). Compared with the non-COVID-19 group, the risk of overall perioperative adverse events was higher in the COVID-19 group diagnosed 0-2 weeks before anesthesia (OR, 6.5; 95% CI, 2.1-20.4) or symptomatic on the anesthesia day (OR, 6.4; 95% CI, 3.30-12.4). CONCLUSION: Pediatric patients with the preoperative COVID-19 omicron variant had increased risk of PRAEs. Patients within 2 weeks after COVID-19 or those with symptoms had a higher risk of PRAEs.


Assuntos
COVID-19 , Criança , Humanos , Estudos Retrospectivos , COVID-19/etiologia , SARS-CoV-2 , Anestesia Geral/efeitos adversos
18.
Int J Dent Hyg ; 21(3): 497-504, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36764701

RESUMO

OBJECTIVES: Job autonomy focuses on the job performance and tasks of health providers with a national licence in South Korea, which affects job crafting, to develop job competency. This study was conducted to identify the influence of job autonomy on job crafting of dental hygienists. METHODS: This cross-sectional study included 411 dental hygienists extracted through convenience sampling from a pool of 35,000 clinical dental hygienists in South Korea. Measuring tool are Korean version of the Job Crafting Questionnaire (JCQ-K) and job autonomy questionnaire (JAQ). To investigate the level of job autonomy and crafting of dental hygienists based on their general characteristics, t-tests and one-way ANOVAs were performed. Pearson correlation was performed to determine the linear correlation between autonomy and crafting. To determine whether job autonomy affects job crafting, an adjusted regression analysis was conducted using general characteristics as control variables. RESULTS: High job autonomy and job crafting were associated with increases in participant age with job experience as a senior staff, education level, and work environment, such as dental office or hospital. A significant positive correlation was observed (r = 0.64) between job autonomy and job crafting. Job autonomy (ß = 0.58) and dental/medical hospital in university (ß = 0.13) had a significant relationship with dental hygienists' job crafting. CONCLUSIONS: Job autonomy could positively influence the job crafting of dental hygienists in South Korea. Our findings suggest that job latitude should be redesigned to promote task competency and social responsibility with a health outcome perspective for the population as well as the dental hygiene profession.


Assuntos
Higienistas Dentários , Satisfação no Emprego , Humanos , Estudos Transversais , Higienistas Dentários/educação , Inquéritos e Questionários , Escolaridade
19.
Br J Anaesth ; 128(1): 214-221, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34686309

RESUMO

BACKGROUND: Limited data exist regarding optimal intraoperative ventilation strategies for the paediatric population. This study aimed to determine the optimal combination of PEEP and tidal volume (VT) based on intratidal compliance profiles in healthy young children undergoing general anaesthesia. METHODS: During anaesthesia, infants (1 month-1 yr), toddlers (1-3 yr), and children (3-6 yr) were assigned serially to four ventilator settings: PEEP 8 cm H2O/VT 8 ml kg-1 (PEEP8/VT8), PEEP 10 cm H2O/VT 5 ml kg-1 (PEEP10/VT5), PEEP 10 cm H2O/VT 8 ml kg-1 (PEEP10/VT8), and PEEP 12 cm H2O/VT 5 ml kg-1 (PEEP12/VT5). The primary outcome was intratidal compliance profile, classified at each ventilator setting as horizontal (indicative of optimal alveolar ventilatory conditions), increasing, decreasing, or combinations of increasing/decreasing/horizontal compliance. Secondary outcomes were peak inspiratory, plateau, and driving pressures. RESULTS: Intratidal compliance was measured in 15 infants, 13 toddlers, and 15 children (15/43 [35%] females). A horizontal compliance profile was most frequently observed with PEEP10/VT5 (60.5%), compared with PEEP10/VT8, PEEP8/VT8, and PEEP12/VT5 (23.3-34.9%; P<0.001). Decreasing compliance profiles were most frequent when VT increased to 8 ml kg-1, PEEP increased to 12 cm H2O, or both. Plateau airway pressures were lower at PEEP8/VT8 (16.9 cm H2O [2.2]) and PEEP10/VT5 (16.7 cm H2O [1.7]), compared with PEEP10/VT8 (19.5 cm H2O [2.1]) and PEEP12/VT5 (19.0 cm H2O [2.0]; P<0.001). Driving pressure was lowest with PEEP10/VT5 (4.6 cm H2O), compared with other combinations (7.0 cm H2O [2.0]-9.5 cm H2O [2.1]; P<0.001). CONCLUSIONS: VT 5 ml kg-1 combined with 10 cm H2O PEEP may reduce atelectasis and overdistension, and minimise driving pressure in the majority of mechanically ventilated children <6 yr. The effect of these PEEP and VT settings on postoperative pulmonary complications in children undergoing surgery requires further study. CLINICAL TRIAL REGISTRATION: NCT04633720.


Assuntos
Respiração com Pressão Positiva/métodos , Complicações Pós-Operatórias/epidemiologia , Respiração Artificial/métodos , Volume de Ventilação Pulmonar/fisiologia , Anestesia Geral/métodos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Cuidados Intraoperatórios/métodos , Complacência Pulmonar/fisiologia , Masculino , Estudos Prospectivos , Atelectasia Pulmonar/prevenção & controle
20.
Acta Anaesthesiol Scand ; 66(7): 803-810, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35403238

RESUMO

BACKGROUND: Pupil dilation reflex measured by a pupillometer is known to be a useful parameter for assessing the response to perioperative noxious stimuli. In children, pupillometer can reflect changes after painful stimuli during anaesthesia or guide anaesthesia to reduce opioid consumption. However, to date, there are no data regarding pupil response during inhalation anaesthesia with analgesia by intravenous acetaminophen in children. METHODS: We planned a prospective, single-armed study of children aged between 3 and 12 years who underwent surgery under general anaesthesia. Anaesthesia was maintained by 1 minimum alveolar concentration (MAC) of sevoflurane, and 15 mg/kg of acetaminophen was administered. Patients' left eye was examined using a pupillometer after induction, before and after skin incision and train-of-four stimulus. Pupil diameter and other pupillometric parameters were recorded. Increase in heart rate by 15% was regarded as insufficient analgesia to skin incision and indicative powers of pupillometric parameters for insufficient analgesia were examined by receiver-operating characteristics. RESULTS: A total of 33 patients were included. Enlarged pupil, large increase in pupil diameter and low neurological pupil index (NPi) after skin incision were good indicators of insufficient analgesia for skin incision. Children with insufficient analgesia showed abnormal NPi value. However, increase in pupil diameter and decrease in NPi were observed even in patients without increase in the heart rate after the skin incision. CONCLUSIONS: We suggest dilation of the pupil and decrease in NPi can indicate response to noxious stimuli in children. Regardless of sufficiency of analgesia, pupil dilation and decrease in NPi were observed after skin incision in children under general anaesthesia with 1 MAC of sevoflurane and intravenous acetaminophen.


Assuntos
Analgésicos Opioides , Anestésicos Inalatórios , Acetaminofen , Analgésicos Opioides/uso terapêutico , Anestesia por Inalação , Anestésicos Inalatórios/farmacologia , Criança , Pré-Escolar , Humanos , Estudos Prospectivos , Pupila/fisiologia , Sevoflurano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA