Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
World J Urol ; 37(7): 1281-1287, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30288597

RESUMO

INTRODUCTION: Radiotherapy to the bladder has a risk of toxicity to pelvic structures, which can be reduced by using fiducial markers for targeting. Injectable contrast offers an alternative marker to gold seeds, which may fall out or exacerbate scarring. Combining contrast agents with tissue glue can minimize dispersion through tissue, enhancing its utility. We evaluated combinations of contrast agents and tissue glue using porcine bladder, for feasibility and utility as fiducial markers to aid image-guided radiotherapy. METHODS: Different contrast agents (Lipiodol ultra or Urografin) were combined with different tissue glues (Histoacryl, Tisseal or Glubran2). The mixtures were endoscopically injected into porcine bladder submucosa to identify the area of interest with multiple fiducial markers. The porcine bladders were imaged within a phantom porcine pelvis using standard radiation therapy imaging modalities. The feasibility as an injectable fiducial marker and visibility of each fiducial marker on imaging were scored as binary outcomes by two proceduralists and two radiation therapists, respectively. RESULTS: Lipiodol-glue combinations were successfully administered as multiple fiducials that were evident on CT and CBCT. Lipiodol with Histoacryl or Glubran2 was visible on kV imaging. The Lipiodol Glubran2 combination was deemed subjectively easiest to use at delivery, and a better fiducial on KV imaging. CONCLUSION: This study demonstrates the feasibility of mixing contrast medium Lipiodol with Histoacryl or Glubran2 tissue glue, which, injected endoscopically, provides discrete and visible fiducial markers to aid image-guided radiotherapy. Although promising, further study is required to assess the durability of these markers through a course of radiotherapy.


Assuntos
Marcadores Fiduciais , Radioterapia Guiada por Imagem/métodos , Neoplasias da Bexiga Urinária/radioterapia , Animais , Tomografia Computadorizada de Feixe Cônico , Cianoacrilatos , Cistoscopia , Diatrizoato de Meglumina , Embucrilato , Óleo Etiodado , Estudos de Viabilidade , Adesivo Tecidual de Fibrina , Suínos , Adesivos Teciduais , Tomografia Computadorizada por Raios X
3.
Front Oncol ; 12: 1023288, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36818674

RESUMO

Introduction: Image guidance with gold fiducials improves outcomes of prostate radiotherapy. However, gold produces artefact on CT imaging, interfering with contouring and verification. The purpose of this study was to compare polymer to standard gold fiducials using radiotherapy imaging modalities to assess the visibility and artefact. Methods: Twenty eight patients with locally advanced prostate cancer were enrolled, half had three polymer fiducials implanted into the prostate and half underwent insertion of gold fiducials. Patients were imaged with CT, T2 weighted MRI, cone-beam CT (CBCT) and planar KV images. Fiducials were scored for visibility and assessed for CT artefact in surrounding prostate tissue. The artefact was quantified from Hounsfield number histograms and separated into percentile ranges and proportion of voxels in HU normal tissue range of a 2cm sphere surrounding the fiducial. Results: Gold and polymer fiducials were sufficiently visible for CT and CBCT verification. The gold fiducials could be visualized well on KV planar imaging; however, the polymer markers were obscured by pelvic bones. Neither polymer nor gold fiducials could be visualized on MRI. The polymer fiducial produced less artefact than gold on CT, having less voxel spread for the HU percentile ranges and a greater proportion of voxels in the normal tissue range. Conclusions: Polymer fiducials are a more suitable fiducial than gold for CT/CBCT in prostate cancer radiotherapy, demonstrating minimal artefact and good visibility on CT. However, they were not well seen on MRI or KV imaging and thus not suitable for co-registration or planar KV verification.

4.
Sci Rep ; 11(1): 8931, 2021 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-33903651

RESUMO

To assess visibility and artifact characteristics of polymer fiducials compared to standard gold fiducials for radiotherapy CT and MRI simulation. Three gold and three polymer fiducials were inserted into a CT and MRI tissue-equivalent phantom that approximated the prostate cancer radiotherapy configuration. The phantom and fiducials were imaged on CT and MRI. Images were assessed in terms of fiducial visibility and artifact. ImageJ was employed to quantify the pixel gray-scale of each fiducial and artifact. Fiducial gray-scale histograms and profiles were generated for analysis. Objective measurements of the contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and artifact index (AI) were calculated. The CT images showed that the gold fiducials are visually brighter, with greater contrast than the polymer. The higher peak values illustrate this in the line profiles. However, they produce bright radiating and dark shadowing artifacts. This is depicted by the greater width of line profiles and the disruption of phantom area profiles. Quantitatively this results in greater percentile ranges of the histograms. Furthermore, for CT, gold had a higher CNR than polymer, relative to the phantom. However, the gold CNR and SNR were degraded by the greater artifact and thus AI. Both fiducials were visible on MRI and had similar histograms and profiles that were also reflected in comparable CNR, SNR and AI. Polymer fiducials were well visualized in a phantom on CT and MR and produce less artifact than the gold fiducials. Polymer markers could enhance the quality and accuracy of radiotherapy co-registration and planning but require clinical confirmation.

5.
J Med Radiat Sci ; 68(3): 289-297, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33432719

RESUMO

INTRODUCTION: Guidelines recommend that the proximal seminal vesicles (PrSV) should be included in the clinical target volume for locally advanced prostate cancer patients undergoing radiotherapy. Verification and margins for the prostate may not necessarily account for PrSV displacement. The purpose was to determine the inter-fraction displacement of the PrSV relative to the prostate during radiotherapy. METHODS: Fiducials were inserted into the prostate, and right and left PrSV (RSV and LSV) in 30 prostate cancer patients. Correctional shifts for the prostate, right and left PrSV and pelvic bones were determined from each patient's 39 daily orthogonal portal images relative to reference digitally reconstructed radiographs. RESULTS: There was a significant displacement of the RSV relative to the prostate in all directions: on average 0.38 mm (95% confidence interval (CI) 0.26 to 0.50) to the left, 0.80-0.81 mm (CI 0.68 to 0.93) superiorly and 1.51 mm (CI 1.36 to 1.65) posteriorly. The LSV was significantly displaced superiorly to the prostate 1.09-1.13 mm (CI 0.97 to 1.25) and posteriorly 1.81 mm (CI 1.67 to 1.96), but not laterally (mean 0.06, CI -0.06 to 0.18). The calculated PTV margins (left-right, superior-inferior, posterior-anterior) were 4.9, 5.3-5.6 and 4.8 mm for the prostate, 5.2, 7.1-8.0 and 9.7 mm for the RSV, and 7.2, 7.5-7.6 and 8.6 mm for the LSV. CONCLUSION: There is a significant displacement of the PrSV relative to the prostate during radiotherapy. Greater margins are recommended for the PrSV compared to the prostate.


Assuntos
Ossos Pélvicos , Neoplasias da Próstata , Radioterapia Guiada por Imagem , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Glândulas Seminais/diagnóstico por imagem
6.
Phys Imaging Radiat Oncol ; 17: 77-83, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33898783

RESUMO

BACKGROUND AND PURPOSE: Image-guidance with fiducials has been shown to improve pelvic radiotherapy outcome. However, bladder fiducials using ethiodized oil (EO) alone can disperse widely, and gold causes Computed Tomography scan (CT) metal artifacts. The study's purpose was to investigate the ability to deliver EO-tissue glue fiducials and compare them to gold for bladder radiotherapy image guidance. MATERIALS AND METHODS: A fluid-filled porcine bladder model was used to assess the ability to cystoscopically inject visible EO glue fiducials into the submucosa. We then transferred the bladders into a porcine pelvis for imaging and compared them to gold fiducials using CT, Cone Beam CT (CBCT), and kilovoltage (KV) planar views. A tissue-equivalent phantom was utilized to analyze the CT number Hounsfield Unit (HU) characteristics and artifacts of the glue and gold fiducials. Percentile ranges and normal tissue voxel percentages of the subsequent CT number voxel histogram from a 2 cm sphere surrounding the fiducial was used to characterize the artifact. RESULTS: We successfully delivered all EO glue fiducials into the porcine bladders as discrete fiducials. They were well seen on CT, CBCT, and KV imaging. The glue fiducials had lower CT number values, but less CT number spread of the voxel percentile ranges consistent with the diminished contrast and less artifact than gold. The glue fiducial types had similar CT number characteristics. CONCLUSION: This study has shown that EO glue fiducials can be delivered with online visualization qualities comparable to gold fiducials without metal-related artifacts.

7.
J Med Imaging Radiat Oncol ; 65(3): 365-373, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33890425

RESUMO

INTRODUCTION: Stereotactic body radiotherapy (SBRT) is an emerging, therapeutic option in the management of hepatocellular carcinoma (HCC). A multicentre Liver Ablative Stereotactic Radiation (LASR) database was established to provide a collaborative platform for Australian institutions to define the practice of liver SBRT for HCC. This study explores the patterns of SBRT practice amongst Australian institutions. METHODS: This was a multi-institutional retrospective study of patients treated with SBRT for HCC at 10 institutions between January 2013 and December 2019. Patients' demographics, disease characteristics and SBRT details were evaluated. RESULTS: Three hundred and seventeen patients were evaluated with a median age of 67 years (range, 32-90). Liver cirrhosis was present in 88.6%, baseline Child-Pugh score was A5/6 in 85.1% and B7/8 in 13.2%. Median size of HCC treated was 30 mm (range, 10-280). 63.1% had early-stage disease (Barcelona clinic liver cancer (BCLC) stage 0/A) and 36% had intermediate/advanced-stage disease (BCLC B/C). In 2013/2014, six courses of SBRT were delivered, increasing to 108 in 2019. SBRT was prescribed in five fractions for 71.3% of the cohort. The most common dose fractionation schedule was 40 Gy in five fractions (24.3%). Median biologically effective dose (BED10 ) delivered was 85.5 Gy for early-stage and 60 Gy for intermediate/advanced disease, respectively. The most common prescription range was 100-120 Gy BED10 (32.8%). CONCLUSION: SBRT utilisation for HCC is increasing in Australia. There was wide variation in size of tumours and disease stages treated, and prescription patterns. Uniform reporting of clinical and dosimetric details are important in refining the role of liver SBRT.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Radiocirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Austrália , Carcinoma Hepatocelular/radioterapia , Carcinoma Hepatocelular/cirurgia , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos
8.
Radiother Oncol ; 125(1): 113-117, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28939178

RESUMO

BACKGROUND: Vesico-urethral anastomosis (VUA) is critical to the clinical target volume (CTV) in post-prostatectomy radiotherapy (PPRT), as it is the commonest site of recurrence. Typically, this is performed on a CT alone but guidelines recommend MRI. OBJECTIVE: To evaluate the VUA spatial differences between CT (ctVUA) and MRI (mrVUA) and analyse its impact on the CT defined CTV (ctCTV) as recommended by published guidelines. MATERIALS AND METHODS: We identified 34 patients with a co-registered simulation CT and T2 weighted MRI. The VUA was located on CT and MRI whilst blinded to the opposing scan. The differences were analysed using Wilcoxon's Signed Rank Test. The mrVUA coverage was investigated using three ctCTV margins of 5mm, 8mm and 12mm. RESULTS: Median age was 63years with 59% having pT3a disease and median Gleason score of 7. The mrVUA was coincident with the ctVUA in 12% and inferior in 88%. Median difference was 5mm (0-10mm) (P<0.0001). Only a ctCTV margin of 12mm would have encompassed all mrVUAs. A ctCTV margin of 8mm and 5mm resulted in 12% and 38% cases where the VUA was excluded from the ctCTV. CONCLUSIONS: MRI is important for the accurate delineation of VUA for PPRT.


Assuntos
Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/radioterapia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Anastomose Cirúrgica/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Estadiamento de Neoplasias , Prostatectomia/métodos , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Tomografia Computadorizada por Raios X/métodos , Uretra/diagnóstico por imagem , Uretra/cirurgia , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA