Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 147(14): 1053-1063, 2023 04 04.
Artigo em Inglês | MEDLINE | ID: mdl-36621817

RESUMO

BACKGROUND: Low-density lipoprotein cholesterol (LDL-C) is an important causal risk factor for atherosclerotic cardiovascular disease (ASCVD). However, a sizable proportion of middle-aged individuals with elevated LDL-C level have not developed coronary atherosclerosis as assessed by coronary artery calcification (CAC). Whether presence of CAC modifies the association of LDL-C with ASCVD risk is unknown. We evaluated the association of LDL-C with future ASCVD events in patients with and without CAC. METHODS: The study included 23 132 consecutive symptomatic patients evaluated for coronary artery disease using coronary computed tomography angiography (CTA) from the Western Denmark Heart Registry, a seminational, multicenter-based registry with longitudinal registration of patient and procedure data. We assessed the association of LDL-C level obtained before CTA with ASCVD (myocardial infarction and ischemic stroke) events occurring during follow-up stratified by CAC>0 versus CAC=0 using Cox regression models adjusted for baseline characteristics. Outcomes were identified through linkage among national registries covering all hospitals in Denmark. We replicated our results in the National Heart, Lung, and Blood Institute-funded Multi-Ethnic Study of Atherosclerosis. RESULTS: During a median follow-up of 4.3 years, 552 patients experienced a first ASCVD event. In the overall population, LDL-C (per 38.7 mg/dL increase) was associated with ASCVD events occurring during follow-up (adjusted hazard ratio [aHR], 1.14 [95% CI, 1.04-1.24]). When stratified by the presence or absence of baseline CAC, LDL-C was only associated with ASCVD in the 10 792/23 132 patients (47%) with CAC>0 (aHR, 1.18 [95% CI, 1.06-1.31]); no association was observed among the 12 340/23 132 patients (53%) with CAC=0 (aHR, 1.02 [95% CI, 0.87-1.18]). Similarly, a very high LDL-C level (>193 mg/dL) versus LDL-C <116 mg/dL was associated with ASCVD in patients with CAC>0 (aHR, 2.42 [95% CI, 1.59-3.67]) but not in those without CAC (aHR, 0.92 [0.48-1.79]). In patients with CAC=0, diabetes, current smoking, and low high-density lipoprotein cholesterol levels were associated with future ASCVD events. The principal findings were replicated in the Multi-Ethnic Study of Atherosclerosis. CONCLUSIONS: LDL-C appears to be almost exclusively associated with ASCVD events over ≈5 years of follow-up in middle-aged individuals with versus without evidence of coronary atherosclerosis. This information is valuable for individualized risk assessment among middle-aged people with or without coronary atherosclerosis.


Assuntos
Aterosclerose , Doenças Cardiovasculares , Doença da Artéria Coronariana , Calcificação Vascular , Pessoa de Meia-Idade , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/complicações , LDL-Colesterol , Doenças Cardiovasculares/complicações , Fatores de Risco , Medição de Risco/métodos , Sistema de Registros , Dinamarca/epidemiologia , Calcificação Vascular/complicações
2.
Eur Radiol ; 34(4): 2677-2688, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37798406

RESUMO

OBJECTIVE: To assess the accuracy of a virtual stenting tool based on coronary CT angiography (CCTA) and fractional flow reserve (FFR) derived from CCTA (FFRCT Planner) across different levels of image quality. MATERIALS AND METHODS: Prospective, multicenter, single-arm study of patients with chronic coronary syndromes and lesions with FFR ≤ 0.80. All patients underwent CCTA performed with recent-generation scanners. CCTA image quality was adjudicated using the four-point Likert scale at a per-vessel level by an independent committee blinded to the FFRCT Planner. Patient- and technical-related factors that could affect the FFRCT Planner accuracy were evaluated. The FFRCT Planner was applied mirroring percutaneous coronary intervention (PCI) to determine the agreement with invasively measured post-PCI FFR. RESULTS: Overall, 120 patients (123 vessels) were included. Invasive post-PCI FFR was 0.88 ± 0.06 and Planner FFRCT was 0.86 ± 0.06 (mean difference 0.02 FFR units, the lower limit of agreement (LLA) - 0.12, upper limit of agreement (ULA) 0.15). CCTA image quality was assessed as excellent (Likert score 4) in 48.3%, good (Likert score 3) in 45%, and sufficient (Likert score 2) in 6.7% of patients. The FFRCT Planner was accurate across different levels of image quality with a mean difference between FFRCT Planner and invasive post-PCI FFR of 0.02 ± 0.07 in Likert score 4, 0.02 ± 0.07 in Likert score 3 and 0.03 ± 0.08 in Likert score 2, p = 0.695. Nitrate dose ≥ 0.8mg was the only independent factor associated with the accuracy of the FFRCT Planner (95%CI - 0.06 to - 0.001, p = 0.040). CONCLUSION: The FFRCT Planner was accurate in predicting post-PCI FFR independent of CCTA image quality. CLINICAL RELEVANCE STATEMENT: Being accurate in predicting post-PCI FFR across a wide spectrum of CT image quality, the FFRCT Planner could potentially enhance and guide the invasive treatment. Adequate vasodilation during CT acquisition is relevant to improve the accuracy of the FFRCT Planner. KEY POINTS: • The fractional flow reserve derived from coronary CT angiography (FFRCT) Planner is a novel tool able to accurately predict fractional flow reserve after percutaneous coronary intervention. • The accuracy of the FFRCT Planner was confirmed across a wide spectrum of CT image quality. Nitrates dose at CT acquisition was the only independent predictor of its accuracy. • The FFRCT Planner could potentially enhance and guide the invasive treatment.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Estenose Coronária/terapia , Valor Preditivo dos Testes
3.
Catheter Cardiovasc Interv ; 100(5): 801-809, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36153649

RESUMO

PURPOSE: The present article aims to compare a novel sizing chart based on both maximum and minimum diameters (novel MATRIX) with the current sizing recommendation instructions for use (IFU) based on the maximum diameter. BACKGROUND: Current IFU with the Amulet device are still based on the maximum left atrial appendage (LAA) diameter, which might lead to inappropriate oversizing, especially in elliptic appendages. METHODS: This was a retrospective analysis of patients undergoing LAA occlusion in two high-volume centers. Two hundred patients were included (100 patients with baseline cardiac computed tomography angiography [CCTA] and 100 with baseline 2D and 3D-transesophageal echocardiography [TEE]). The degree of concordance between the predicted device size recommendation and the actual device selection was the primary outcome. RESULTS: The novel MATRIX showed a higher level of concordance between the predicted and implanted device size, regardless of imaging modalities. CCTA showed the strongest, and 2D-TEE the weakest concordance between the predicted and implanted device for both MATRIX and IFU charts. The percentage of patients in whom the disagreement among the predicted and implanted device represented >1 size was higher when using the IFU chart. In elliptical LAA anatomies, the differences favoring the use of MATRIX compared to the IFU in terms of predicted/implanted agreement were higher. Finally, no significant differences in clinical or imaging endpoints were observed between the two different sizing charts. CONCLUSIONS: Incorporating both the LAA maximum and minimum diameters, as opposed to just maximum diameter, appears to improve sizing accuracy. The proposed MATRIX sizing chart offered a higher level of concordance between predicted and implanted device compared to the current IFU.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Resultado do Tratamento , Ecocardiografia Transesofagiana
4.
Europace ; 24(5): 828-834, 2022 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-35041000

RESUMO

AIMS: This study aims to investigate the long-term occurrence of the composite endpoint of heart failure (HF) hospitalization or all-cause death (primary endpoint) in patients randomized to cardiac resynchronization therapy (CRT) using individualized multimodality imaging-guided left ventricular (LV) lead placement compared with a routine fluoroscopic approach. Furthermore, this study aims to evaluate whether inter-lead electrical delay (IED) is associated with improved response rate of this endpoint. METHODS AND RESULTS: We reviewed follow-up data until November 2020 for all 182 patients included in the ImagingCRT trial for the occurrence of HF hospitalization and all-cause death. During median (inter-quartile range) time to primary endpoint/censuring of 6.7 (3.3-7.9) years, the rate of the primary endpoint was 60% (n = 53) in the imaging group compared with 52% (n = 48) in the control group [hazard ratio (HR) 1.22, 95% confidence interval (CI) 0.83-1.81, P = 0.31]. Neither the risk of HF hospitalization (HR 1.11, 95% CI 0.62-1.99, P = 0.72) nor of all-cause death differed between treatment groups (HR 1.23, 95% CI 0.82-1.85, P = 0.32). The risk of the primary endpoint was significantly reduced among those with IED ≥100 ms when compared with those with IED <100 ms (HR 0.62, 95% CI 0.39-0.98, P = 0.04). CONCLUSIONS: In this study, an individualized multimodality imaging-guided strategy targeting LV lead placement towards the latest mechanically activated non-scarred myocardial segment during CRT implantation did not reduce HF hospitalization or all-cause death when compared with routine LV lead placement during long-term follow-up. Targeting the latest electrical activation should be studied as an alternative individualized strategy for optimizing LV lead placement in CRT recipients.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Resultado do Tratamento
5.
J Comput Assist Tomogr ; 45(3): 408-414, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33797438

RESUMO

OBJECTIVE: This study aimed to investigate the outcome of computed tomography (CT) angiography with optional CT-derived fractional flow reserve (FFRCT) of intermediate-range coronary artery disease in non-emergent patients referred on a suspicion of chronic coronary syndrome. METHODS: Patients were classified as high risk and low-intermediate risk according to the presence of typical angina or either atypical or nonangina chest pain. Outcome was assessed as the cumulative incidence proportion of a composite end point of unstable angina pectoris, unplanned revascularization, nonfatal myocardial infarction, and all-cause mortality. RESULTS: The study included 743 patients. Mean follow-up was 2.2 (range, 0.1-2.5) years. Low-intermediate-risk and high-risk patients who had invasive coronary angiography deferred had comparable proportions of adverse events (1.4% vs 2.6% [P = 0.27]). Adverse events in high-risk patients with FFRCT >0.80 was 3.3% versus 1.4% in patients where no additional testing was performed (P = 0.79). CONCLUSIONS: Computed tomography-derived fractional flow reserve >0.8 conveys an excellent prognosis. Computed tomography angiography with optional FFRCT allows for the safe cancellation of invasive coronary angiography in high-risk patients.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Estudos de Coortes , Doença da Artéria Coronariana/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Encaminhamento e Consulta
6.
Europace ; 21(9): 1369-1377, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274152

RESUMO

AIMS: To test in a double-blinded, randomized trial whether the combination of electrically guided left ventricular (LV) lead placement and post-implant interventricular pacing delay (VVd) optimization results in superior increase in LV ejection fraction (LVEF) in cardiac resynchronization therapy (CRT) recipients. METHODS AND RESULTS: Stratified according to presence of ischaemic heart disease, 122 patients were randomized 1:1 to LV lead placement targeted towards the latest electrically activated segment identified by systematic mapping of the coronary sinus tributaries during CRT implantation combined with post-implant VVd optimization (intervention group) or imaging-guided LV lead implantation by cardiac computed tomography venography, 82Rubidium myocardial perfusion imaging and speckle tracking echocardiography targeting the LV lead towards the latest mechanically activated non-scarred myocardial segment (control group). Follow-up was 6 months. Primary endpoint was absolute increase in LVEF. Additional outcome measures were changes in New York Heart Association class, 6-minute walk test, and quality of life, LV reverse remodelling, and device related complications. Analysis was intention-to-treat. A larger increase in LVEF was observed in the intervention group (11 ± 10 vs. 7 ± 11%; 95% confidence interval 0.4-7.9%, P = 0.03); when adjusting for pre-specified baseline covariates this difference did not maintain statistical significance (P = 0.09). Clinical response, LV reverse remodelling, and complication rates did not differ between treatment groups. CONCLUSION: Electrically guided CRT implantation appeared non-inferior to an imaging-guided strategy considering the outcomes of change in LVEF, LV reverse remodelling and clinical response. Larger long-term studies are warranted to investigate the effect of an electrically guided CRT strategy.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Insuficiência Cardíaca/terapia , Implantação de Prótese/métodos , Cirurgia Assistida por Computador/métodos , Disfunção Ventricular Esquerda/terapia , Idoso , Idoso de 80 Anos ou mais , Seio Coronário/diagnóstico por imagem , Seio Coronário/fisiopatologia , Método Duplo-Cego , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons , Qualidade de Vida , Radioisótopos de Rubídio , Volume Sistólico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Remodelação Ventricular/fisiologia , Teste de Caminhada
7.
Ann Noninvasive Electrocardiol ; 24(3): e12621, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30521128

RESUMO

BACKGROUND: QRS narrowing after CRT is a predictor of patient outcome. Further narrowing can be obtained by interventricular pacing delay (VVd) optimization, raising interest to inter and intraobserver variation in manual measurements of QRS duration. METHODS: (a) Variation in intrinsic rhythm QRS duration in CRT patients with LBBB: In 40 intrinsic 12-lead ECGs, six observers measured QRS duration defined as widest QRS in any lead. In 20 of these ECGs, two observers repeated the measurements. (b) Variation in paced QRS duration at different VVd settings and agreement in selecting the narrowest QRS: In 20 CRT patients, five paced ECGs were recorded at different VVds. The most frequently selected VVd(s) estimated to cause the narrowest QRS in each patient defined the optimal VVd. Two observers repeated the measurements and VVd selections. RESULTS: Absolute interobserver difference in measured QRS duration in intrinsic rhythm ECGs was mean 2 ms, range (-40; 40 ms), mean limits of agreement (LoA): -21; 25 ms. Absolute interobserver difference in measured QRS duration in paced ECGs was mean 3 ms, range (-50; 60 ms), mean LoA: -20; 27 ms. There was no difference in LoA between intrinsic and paced QRS duration (lower limit p = 0.68; upper limit p = 0.44). The optimal VVd was included in 17/20 (85%) of the VVd selections by six observers. Interobserver variation was comparable with the intraobserver variation. CONCLUSIONS: Interobserver variation and intraobserver variation in manually measured paced and intrinsic rhythm QRS duration are clinically acceptable and comparable in a cohort of CRT patients. Inter and intraobserver reproducibility for selecting the optimal VVd is good and warrants manual VVd optimization for QRS narrowing in CRT.


Assuntos
Bloqueio de Ramo/diagnóstico por imagem , Terapia de Ressincronização Cardíaca/métodos , Causas de Morte , Eletrocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Fatores Etários , Idoso , Bloqueio de Ramo/mortalidade , Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/mortalidade , Estudos de Coortes , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Taxa de Sobrevida
8.
Eur Radiol ; 28(6): 2655-2664, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29352380

RESUMO

OBJECTIVES: We aimed to investigate if lesion-specific ischaemia by invasive fractional flow reserve (FFR) can be predicted by an integrated machine learning (ML) ischaemia risk score from quantitative plaque measures from coronary computed tomography angiography (CTA). METHODS: In a multicentre trial of 254 patients, CTA and invasive coronary angiography were performed, with FFR in 484 vessels. CTA data sets were analysed by semi-automated software to quantify stenosis and non-calcified (NCP), low-density NCP (LD-NCP, < 30 HU), calcified and total plaque volumes, contrast density difference (CDD, maximum difference in luminal attenuation per unit area) and plaque length. ML integration included automated feature selection and model building from quantitative CTA with a boosted ensemble algorithm, and tenfold stratified cross-validation. RESULTS: Eighty patients had ischaemia by FFR (FFR ≤ 0.80) in 100 vessels. Information gain for predicting ischaemia was highest for CDD (0.172), followed by LD-NCP (0.125), NCP (0.097), and total plaque volumes (0.092). ML exhibited higher area-under-the-curve (0.84) than individual CTA measures, including stenosis (0.76), LD-NCP volume (0.77), total plaque volume (0.74) and pre-test likelihood of coronary artery disease (CAD) (0.63); p < 0.006. CONCLUSIONS: Integrated ML ischaemia risk score improved the prediction of lesion-specific ischaemia by invasive FFR, over stenosis, plaque measures and pre-test likelihood of CAD. KEY POINTS: • Integrated ischaemia risk score improved prediction of ischaemia over quantitative plaque measures • Integrated ischaemia risk score showed higher prediction of ischaemia than standard approach • Contrast density difference had the highest information gain to identify lesion-specific ischaemia.


Assuntos
Aprendizado de Máquina , Isquemia Miocárdica/diagnóstico por imagem , Calcificação Vascular/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/fisiopatologia , Índice de Gravidade de Doença , Calcificação Vascular/fisiopatologia
9.
Eur J Clin Invest ; 47(8): 565-573, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28657113

RESUMO

BACKGROUND: Population studies report increased cardiovascular mortality in patients with cirrhosis. Coronary artery disease may be a trait of end-stage liver disease, but whether it is frequent or extensive in cirrhosis in general is unknown. Thus, we aimed to assess the prevalence and extent of coronary artery disease in unselected cirrhosis patients. MATERIALS AND METHODS: Using coronary computed tomography angiography, we investigated 52 patients from all Child-Pugh classes and aetiologies of cirrhosis without known cardiac disease for presence and severity of coronary artery disease in a cross-sectional design. Persons referred with new-onset chest pain served as controls. RESULTS: The prevalence of coronary artery disease was not significantly different between cirrhosis patients and controls (77% vs. 65%, P=0·19). However, cirrhosis patients had a markedly higher coronary artery calcification (Agatston) score than controls (120 [interquartile range, 0-345] vs. 5 [interquartile range, 0-86] HU, P=0·001). Likewise, patients with cirrhosis had a higher prevalence of extensive (≥5 coronary segments involved; 45% vs. 18%, P=0·01) and multivessel coronary disease (≥2 vessels involved; 75% vs. 53%, P=0·02). Furthermore, the total plaque volume whether noncalcified or calcified was higher in cirrhosis (117 [interquartile range, 0-310] vs. 36 [interquartile range, 0-148] mm3 , P=0·02). CONCLUSION: Coronary artery disease is equally prevalent in patients with cirrhosis and subjects with new-onset chest pain, but cirrhosis patients have more extensive and severe disease including several coronary high-risk features associated with myocardial ischaemia and a poor clinical outcome. The potential of preventive measures for coronary artery disease in cirrhosis needs attention.


Assuntos
Doença da Artéria Coronariana/etiologia , Cirrose Hepática/complicações , Estudos de Casos e Controles , Angiografia por Tomografia Computadorizada , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Calcificação Vascular/etiologia
10.
Curr Cardiol Rep ; 19(11): 112, 2017 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-28940026

RESUMO

PURPOSE OF REVIEW: To summarize the scientific basis of CT derived fractional flow reserve (FFRCT) and present an updated review on the evidence from clinical trials and real-world observational data RECENT FINDINGS: In prospective multicenter studies of patients with stable coronary artery disease (CAD), FFRCT showed high diagnostic performance. More recently, FFRCT has advanced to the realm of clinical utility and real-world clinical practice with emerging data showing that FFRCT when compared to standard care is efficient in safely reducing downstream utilization of invasive coronary angiography (ICA), and costs, as well as improving the diagnostic yield of ICA. Moreover, FFRCT may broaden applicability of frontline coronary CTA testing to patients with high pre-test risk of CAD. Introducing FFRCT into clinical practice has the potential to significantly improve the management of patients with stable CAD. The optimal FFRCT testing interpretation strategy, as well as the relative cost-efficiency of FFRCT against standard noninvasive functional testing, need further investigation.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Tomografia Computadorizada/economia , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Angiografia Coronária/economia , Angiografia Coronária/estatística & dados numéricos , Doença da Artéria Coronariana/terapia , Humanos , Estudos Multicêntricos como Assunto , Estudos Prospectivos
11.
Eur Heart J ; 37(15): 1220-7, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-26763790

RESUMO

AIMS: Coronary plaque characteristics are associated with ischaemia. Differences in plaque volumes and composition may explain the discordance between coronary stenosis severity and ischaemia. We evaluated the association between coronary stenosis severity, plaque characteristics, coronary computed tomography angiography (CTA)-derived fractional flow reserve (FFRCT), and lesion-specific ischaemia identified by FFR in a substudy of the NXT trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps). METHODS AND RESULTS: Coronary CTA stenosis, plaque volumes, FFRCT, and FFR were assessed in 484 vessels from 254 patients. Stenosis >50% was considered obstructive. Plaque volumes (non-calcified plaque [NCP], low-density NCP [LD-NCP], and calcified plaque [CP]) were quantified using semi-automated software. Optimal thresholds of quantitative plaque variables were defined by area under the receiver-operating characteristics curve (AUC) analysis. Ischaemia was defined by FFR or FFRCT ≤0.80. Plaque volumes were inversely related to FFR irrespective of stenosis severity. Relative risk (95% confidence interval) for prediction of ischaemia for stenosis >50%, NCP ≥185 mm(3), LD-NCP ≥30 mm(3), CP ≥9 mm(3), and FFRCT ≤0.80 were 5.0 (3.0-8.3), 3.7 (2.4-5.6), 4.6 (2.9-7.4), 1.4 (1.0-2.0), and 13.6 (8.4-21.9), respectively. Low-density NCP predicted ischaemia independent of other plaque characteristics. Low-density NCP and FFRCT yielded diagnostic improvement over stenosis assessment with AUCs increasing from 0.71 by stenosis >50% to 0.79 and 0.90 when adding LD-NCP ≥30 mm(3) and LD-NCP ≥30 mm(3) + FFRCT ≤0.80, respectively. CONCLUSION: Stenosis severity, plaque characteristics, and FFRCT predict lesion-specific ischaemia. Plaque assessment and FFRCT provide improved discrimination of ischaemia compared with stenosis assessment alone.


Assuntos
Isquemia Miocárdica/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Feminino , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/fisiopatologia , Placa Aterosclerótica/fisiopatologia , Remodelação Ventricular/fisiologia
12.
EuroIntervention ; 20(11): e718-e727, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38840576

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) is performed increasingly, but long-term follow-up imaging data are lacking. AIMS: The aim of this study was to evaluate the safety and durability of the Amplatzer Amulet device >4 years after LAAO. METHODS: This was a prospective observational cohort study including 52 patients implanted with the Amplatzer Amulet device at Aarhus University Hospital, Denmark. A >4-year follow-up cardiac computed tomography (CT) scan after LAAO was performed and compared with the results from the 2-month and 12-month scans. The primary outcome was left atrial appendage (LAA) sealing based on distal LAA contrast patency and peridevice leakage (PDL), stratified into complete occlusion (grade 0 [G0]) and grade 1-3 leakage (G1-3), respectively. Secondary outcomes were low- and high-grade hypoattenuated thickening (HAT), device-related thrombosis (DRT) and device durability. RESULTS: The median (interquartile range [IQR]) follow-up time from LAAO to the latest CT scan was 5.8 years (4.5; 6.3). At 2-month (n=52), 12-month (n=27) and >4-year CT follow-ups (n=52), rates of both complete occlusion (33%, 37%, 35%) and G2 leaks (52%, 52%, 48%) remained stable. Rates of G1 leaks varied (14%, 4%, 6%) and G3 leaks rose (2%, 7%, 12%) from earliest to latest follow-up. The median left atrial (LA) volume increased from 127 mL (96; 176) to 144 mL (108; 182) and 147 mL (107; 193). No DRT was found. The structural device integrity was preserved. CONCLUSIONS: This study indicates a stable LAA sealing status throughout the follow-up period, emphasising the importance of the procedural result in avoiding PDL. Few patients displayed PDL progression, which might partly be related to LA remodelling with increasing volume. The long-term device durability appears excellent. Larger studies are warranted to confirm these findings.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Tomografia Computadorizada por Raios X , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Apêndice Atrial/fisiopatologia , Masculino , Feminino , Idoso , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Estudos Prospectivos , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Pessoa de Meia-Idade , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação
13.
Am J Hypertens ; 37(7): 455-464, 2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38477704

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is associated with accelerated vascular calcification and increased central systolic blood pressure when measured invasively (invCSBP) relative to cuff-based brachial systolic blood pressure (cuffSBP). The contribution of aortic wall calcification to this phenomenon has not been clarified. We, therefore, examined the effects of aortic calcification on cuffSBP and invCSBP in a cohort of patients representing all stages of CKD. METHODS: During elective coronary angiography, invCSBP was measured in the ascending aorta with a fluid-filled catheter with simultaneous recording of cuffSBP using an oscillometric device. Furthermore, participants underwent a non-contrast computed tomography scan of the entire aorta with observer-blinded calcification scoring of the aortic wall ad modum Agatston. RESULTS: We included 168 patients (mean age 67.0 ±â€…10.5, 38 females) of whom 38 had normal kidney function, while 30, 40, 28, and 32 had CKD stages 3a, 3b, 4, and 5, respectively. Agatston scores adjusted for body surface area ranged from 48 to 40,165. We found that invCSBP increased 3.6 (95% confidence interval 1.4-5.7) mm Hg relative to cuffSBP for every 10,000-increment in aortic Agatston score. This association remained significant after adjustment for age, diabetes, antihypertensive treatment, smoking, eGFR, and BP level. No such association was found for diastolic BP. CONCLUSIONS: Patients with advanced aortic calcification have relatively higher invCSBP for the same cuffSBP as compared to patients with less calcification. Advanced aortic calcification in CKD may therefore result in hidden central hypertension despite apparently well-controlled cuffSBP. ClinicalTrials.gov identifier: NCT04114695.


Assuntos
Determinação da Pressão Arterial , Insuficiência Renal Crônica , Calcificação Vascular , Humanos , Feminino , Masculino , Idoso , Pessoa de Meia-Idade , Insuficiência Renal Crônica/fisiopatologia , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Determinação da Pressão Arterial/métodos , Doenças da Aorta/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Pressão Sanguínea , Angiografia por Tomografia Computadorizada , Artéria Braquial/fisiopatologia , Artéria Braquial/diagnóstico por imagem , Angiografia Coronária , Aortografia , Valor Preditivo dos Testes
14.
Artigo em Inglês | MEDLINE | ID: mdl-38789325

RESUMO

BACKGROUND: Coronary CT angiography (CCTA) is well-established for diagnosis and stratification of coronary artery disease (CAD). Its usefulness in guiding percutaneous coronary interventions (PCI) and stent sizing is unknown. METHODS: This is a sub-analysis of the Precise Percutaneous Coronary Intervention Plan (P3) study (NCT03782688). We analyzed 65 vessels with matched CCTA and pre-PCI optical coherence tomography (OCT) assessment. The CCTA-guided stent size was defined by the mean distal reference lumen diameter rounded up to the nearest stent diameter. The OCT lumen-guided stent size was the mean distal reference lumen diameter rounded to the closest stent diameter. The agreement on stent diameters was determined with Kappa statistics, Passing-Bablok regression analysis, and the Bland-Altman method. RESULTS: The distal reference lumen diameter by CCTA and OCT were 2.75 â€‹± â€‹0.53 â€‹mm and 2.72 â€‹± â€‹0.55 â€‹mm (mean difference 0.06, limits of agreement -0.7 to 0.82). There were no proportional or systematic differences (coefficient A 1.06, 95% CI 0.84 to 1.3 and coefficient B -0.22, 95% CI -0.83 to 0.36) between methods. The agreement between the CCTA and OCT stent size was substantial (Cohen's weighted Kappa 0.74, 95% CI 0.64 to 0.85). Compared to OCT stent diameter, CCTA stent size was concordant in 52.3% of the cases; CCTA overestimated stent size in 20.0% and underestimated in 27.7%. CONCLUSION: CCTA accurately assessed the reference vessel diameter used for stent sizing. CCTA-based stent sizing showed a substantial agreement with OCT. CCTA allows for PCI planning and may aid in selecting stent diameter.

15.
J Am Heart Assoc ; 13(5): e032605, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390822

RESUMO

BACKGROUND: Following percutaneous coronary intervention (PCI), optical coherence tomography provides prognosis information. The pullback pressure gradient is a novel index that discriminates focal from diffuse coronary artery disease based on fractional flow reserve pullbacks. We sought to investigate the association between coronary artery disease patterns, defined by coronary physiology, and optical coherence tomography after stent implantation in stable patients undergoing PCI. METHODS AND RESULTS: This multicenter, prospective, single-arm study was conducted in 5 countries (NCT03782688). Subjects underwent motorized fractional flow reserve pullbacks evaluation followed by optical coherence tomography-guided PCI. Post-PCI optical coherence tomography minimum stent area, stent expansion, and the presence of suboptimal findings such as incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were compared between patients with focal versus diffuse disease. Overall, 102 patients (105 vessels) were included. Fractional flow reserve before PCI was 0.65±0.14, pullback pressure gradient was 0.66±0.14, and post-PCI fractional flow reserve was 0.88±0.06. The mean minimum stent area was 5.69±1.99 mm2 and was significantly larger in vessels with focal disease (6.18±2.12 mm2 versus 5.19±1.72 mm2, P=0.01). After PCI, incomplete stent apposition, stent edge dissection, and irregular tissue protrusion were observed in 27.6%, 10.5%, and 51.4% of the cases, respectively. Vessels with focal disease at baseline had a lower prevalence of incomplete stent apposition (11.3% versus 44.2%, P=0.002) and more irregular tissue protrusion (69.8% versus 32.7%, P<0.001). CONCLUSIONS: Baseline coronary pathophysiological patterns are associated with suboptimal imaging findings after PCI. Patients with focal disease had larger minimum stent area and a higher incidence of tissue protrusion, whereas stent malapposition was more frequent in patients with diffuse disease.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
16.
J Am Coll Cardiol ; 83(25): 2643-2654, 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38897674

RESUMO

BACKGROUND: Some autoimmune diseases carry elevated risk for atherosclerotic cardiovascular disease (ASCVD), yet the underlying mechanism and the influence of traditional risk factors remain unclear. OBJECTIVES: This study sought to determine whether autoimmune diseases independently correlate with coronary atherosclerosis and ASCVD risk and whether traditional cardiovascular risk factors modulate the risk. METHODS: The study included 85,512 patients from the Western Denmark Heart Registry undergoing coronary computed tomography angiography. A diagnosis of 1 of 18 autoimmune diseases was assessed. Adjusted OR (aOR) for any plaque, any coronary artery calcification (CAC), CAC of >90th percentile, and obstructive coronary artery disease as well as adjusted HR (aHR) for ASCVD were calculated. RESULTS: During 5.3 years (Q1-Q3: 2.8-8.2 years) of follow-up, 3,832 ASCVD events occurred. A total of 4,064 patients had a diagnosis of autoimmune disease, which was associated with both presence of any plaque (aOR: 1.29; 95% CI: 1.20-1.40), any CAC (aOR: 1.28; 95% CI: 1.19-1.37), and severe CAC of >90th percentile (aOR: 1.53; 95% CI: 1.39-1.68), but not with having obstructive coronary artery disease (aOR: 1.04; 95% CI: 0.91-1.17). Patients with autoimmune diseases had a 46% higher risk (aHR: 1.46; 95% CI: 1.29-1.65) for ASCVD. Traditional cardiovascular risk factors were strongly associated with future ASCVD events, and a favorable cardiovascular risk factor profile in autoimmune patients was associated with ∼54% lower risk compared to patients with presence of risk factors (aHR: 0.46; 95% CI: 0.27-0.81). CONCLUSIONS: Autoimmune diseases were independently associated with higher burden of coronary atherosclerosis and higher risk for future ASCVD events, with risk accentuated by traditional cardiovascular risk factors. These findings suggest that autoimmune diseases increase risk through accelerated atherogenesis and that cardiovascular risk factor control is key for improving prognosis in patients with autoimmune diseases.


Assuntos
Doenças Autoimunes , Doença da Artéria Coronariana , Sistema de Registros , Índice de Gravidade de Doença , Humanos , Doença da Artéria Coronariana/epidemiologia , Masculino , Feminino , Doenças Autoimunes/epidemiologia , Doenças Autoimunes/complicações , Pessoa de Meia-Idade , Idoso , Dinamarca/epidemiologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Fatores de Risco , Isquemia Miocárdica/epidemiologia , Seguimentos
17.
J Cardiovasc Comput Tomogr ; 18(3): 243-250, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38246785

RESUMO

BACKGROUND: The association between coronary computed tomography angiography (CTA) derived fractional flow reserve (FFRCT) and risk of recurrent angina in patients with new onset stable angina pectoris (SAP) and stenosis by CTA is uncertain. METHODS: Multicenter 3-year follow-up study of patients presenting with symptoms suggestive of new onset SAP who underwent first-line CTA evaluation and subsequent standard-of-care treatment. All patients had at least one ≥30 â€‹% coronary stenosis. A per-patient lowest FFRCT-value ≤0.80 represented an abnormal test result. Patients with FFRCT ≤0.80 who underwent revascularization were categorized according to completeness of revascularization: 1) Completely revascularized (CR-FFRCT), all vessels with FFRCT ≤0.80 revascularized; or 2) incompletely revascularized (IR-FFRCT) ≥1 vessels with FFRCT ≤0.80 non-revascularized. Recurrent angina was evaluated using the Seattle Angina Questionnaire. RESULTS: Amongst 769 patients (619 [80 â€‹%] stenosis ≥50 â€‹%, 510 [66 â€‹%] FFRCT ≤0.80), 174 (23 â€‹%) reported recurrent angina at follow-up. An FFRCT ≤0.80 vs â€‹> â€‹0.80 associated to increased risk of recurrent angina, relative risk (RR): 1.82; 95 â€‹% CI: 1.31-2.52, p â€‹< â€‹0.001. Risk of recurrent angina in CR-FFRCT (n â€‹= â€‹135) was similar to patients with FFRCT >0.80, 13 â€‹% vs 15 â€‹%, RR: 0.93; 95 â€‹% CI: 0.62-1.40, p â€‹= â€‹0.72, while IR-FFRCT (n â€‹= â€‹90) and non-revascularized patients with FFRCT ≤0.80 (n â€‹= â€‹285) had increased risk, 37 â€‹% vs 15 â€‹% RR: 2.50; 95 â€‹% CI: 1.68-3.73, p â€‹< â€‹0.001 and 30 â€‹% vs 15 â€‹%, RR: 2.03; 95 â€‹% CI: 1.44-2.87, p â€‹< â€‹0.001, respectively. Use of antianginal medication was similar across study groups. CONCLUSION: In patients with SAP and coronary stenosis by CTA undergoing standard-of-care guided treatment, FFRCT provides information regarding risk of recurrent angina.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Valor Preditivo dos Testes , Recidiva , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Seguimentos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Estenose Coronária/terapia , Fatores de Tempo , Medição de Risco , Angina Estável/fisiopatologia , Angina Estável/diagnóstico por imagem , Angina Estável/terapia , Índice de Gravidade de Doença , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiopatologia , Prognóstico
18.
Int J Cardiol ; 399: 131668, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38141723

RESUMO

BACKGROUND AND AIMS: Coronary hemodynamics impact coronary plaque progression and destabilization. The aim of the present study was to establish the association between focal vs. diffuse intracoronary pressure gradients and wall shear stress (WSS) patterns with atherosclerotic plaque composition. METHODS: Prospective, international, single-arm study of patients with chronic coronary syndromes and hemodynamic significant lesions (fractional flow reserve [FFR] ≤ 0.80). Motorized FFR pullback pressure gradient (PPG), optical coherence tomography (OCT), and time-average WSS (TAWSS) and topological shear variation index (TSVI) derived from three-dimensional angiography were obtained. RESULTS: One hundred five vessels (median FFR 0.70 [Interquartile range (IQR) 0.56-0.77]) had combined PPG and WSS analyses. TSVI was correlated with PPG (r = 0.47, [95% Confidence Interval (95% CI) 0.30-0.65], p < 0.001). Vessels with a focal CAD (PPG above the median value of 0.67) had significantly higher TAWSS (14.8 [IQR 8.6-24.3] vs. 7.03 [4.8-11.7] Pa, p < 0.001) and TSVI (163.9 [117.6-249.2] vs. 76.8 [23.1-140.9] m-1, p < 0.001). In the 51 vessels with baseline OCT, TSVI was associated with plaque rupture (OR 1.01 [1.00-1.02], p = 0.024), PPG with the extension of lipids (OR 7.78 [6.19-9.77], p = 0.003), with the presence of thin-cap fibroatheroma (OR 2.85 [1.11-7.83], p = 0.024) and plaque rupture (OR 4.94 [1.82 to 13.47], p = 0.002). CONCLUSIONS: Focal and diffuse coronary artery disease, defined using coronary physiology, are associated with differential WSS profiles. Pullback pressure gradients and WSS profiles are associated with atherosclerotic plaque phenotypes. Focal disease (as identified by high PPG) and high TSVI are associated with high-risk plaque features. CLINICAL TRIAL REGISTRATION: https://clinicaltrials,gov/ct2/show/NCT03782688.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Placa Aterosclerótica , Humanos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Hemodinâmica , Fenótipo , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Valor Preditivo dos Testes , Estudos Prospectivos
19.
Psychosomatics ; 54(5): 458-65, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23414849

RESUMO

BACKGROUND: Depression is associated with coronary artery disease, and atherosclerosis seems to play a central role in this relation. In several studies, multislice computed tomography (CT) has been applied for detection and quantification of coronary artery calcification (CAC) in relation to depression. To our knowledge, only one previous study has investigated the relation between CAC and depression in an unselected population. METHODS: A total of 617 persons were randomly selected from the background population. The participants underwent CT of the heart and were screened for depression by use of the Major Depression Inventory questionnaire. Quantification of CAC was performed using the Agatston method. The Mann-Whitney U test, Spearman's correlational analysis, and logistic regression were used to assess the association between depression and CAC. RESULTS: The median Agatston score was not significantly different in subjects with depression than in those without depression (p = 0.783), and depression scores did not correlate significantly with Agatston scores (r = 0.023; 95% CI: -0.056-0.102; p = 0.573). This was also the case when correlational analyses were stratified by sex or age. Furthermore, after the exclusion of an outlier, no significant association between CAC and depression was found in either the unadjusted or adjusted logistic regression model, OR = 1.00 (95% CI: 0.88-1.14; p = 0.994) and OR = 1.04 (95% CI: 0.92-1.18; p = 0.529), respectively. CONCLUSIONS: Depression was not associated with CAC in an unselected middle-aged population, although a trend-level association was found in men (p = 0.086).


Assuntos
Doença da Artéria Coronariana/epidemiologia , Depressão/epidemiologia , Calcificação Vascular/epidemiologia , Estudos de Coortes , Doença da Artéria Coronariana/diagnóstico por imagem , Dinamarca , Transtorno Depressivo/epidemiologia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem
20.
Scand J Public Health ; 41(7): 737-43, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23740863

RESUMO

AIMS: Understanding the determinants of social and coping inequalities in subclinical cardiovascular disease is an important prerequisite in developing and implementing preventive strategies. The aim of this study was to investigate the association between social factors and coping status, respectively, and subclinical coronary artery disease (CAD) in middle-aged Danes. METHODS: This is a DanRisk screening substudy, thus including healthy Danish males and females aged 50 or 60 years. Social measures included grade of education, employment and co-habiting status. The coping status was estimated by the general self-efficacy (GES) scale. Coronary artery calcification (CAC) was assessed by computed tomography using the Agatston score (AS). Conventional clinical risk factors included sex, family history of CAD, BMI > 25, smoking, hypercholesterolaemia and hypertension. RESULTS: In 568 individuals the prevalence of subjects with CAC was 267 (45%). Independent predictors of CAC in males were age (OR = 1.10, 95% CI = 1.04-1.16, p < 0.001), smoking (OR = 1.75, 95% CI = 1.03-2.99, p = 0.038), and low co-habiting status (OR = 3.66, 95% CI = 1.19-11.25, p = 0.023). Independent predictors in females were age (OR = 1.67, 95% CI = 1.02-1.12, p = 0.006), and smoking (OR = 1.71, 95% CI = 1.06-2.78, p = 0.029). Higher AS was associated to lower employment level in females (p = 0.001) but not in males (p = 0.833). CONCLUSIONS: Social factors are associated to the prevalence and severity of CAC in asymptomatic middle-aged individuals with gender differences. The relative value of gender specific social versus conventional clinical risk factors in the risk assessment of subclinical CAC in middle-aged individuals needs further investigation in future prospective studies.


Assuntos
Adaptação Psicológica , Doença da Artéria Coronariana/psicologia , Disparidades nos Níveis de Saúde , Determinantes Sociais da Saúde , Calcificação Vascular/psicologia , Doença da Artéria Coronariana/epidemiologia , Dinamarca/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Índice de Gravidade de Doença , Distribuição por Sexo , Fatores Socioeconômicos , Calcificação Vascular/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA