Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Eur Radiol ; 32(12): 8597-8607, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35612663

RESUMO

OBJECTIVES: 4D flow MRI enables quantitative assessment of helical flow. We sought to generate normal values and elucidate changes of helical flow (duration, volume, length, velocities and rotational direction) and flow jet (displacement, flow angle) as well as wall shear stress (WSS). METHODS: We assessed the temporal helical existence (THEX), maximum helical volume (HVmax), accumulated helical volume (HVacc), accumulated helical volume length (HVLacc), maximum forward velocity (maxVfor), maximum circumferential velocity (maxVcirc), rotational direction (RD) and maximum wall shear stress (WSS) as reported elsewhere using the software tool Bloodline in 86 healthy volunteers (46 females, mean age 41 ± 13 years). RESULTS: WSS decreased by 42.1% and maxVfor by 55.7% across age. There was no link between age and gender regarding the other parameters. CONCLUSION: This study provides age-dependent normal values regarding WSS and maxVfor and age- and gender-independent normal values regarding THEX, HVmax, HVacc, HVLacc, RD and maxVcirc. KEY POINTS: • 4D flow provides numerous new parameters; therefore, normal values are mandatory. • Wall shear stress decreases over age. • Maximum helical forward velocity decreases over age.


Assuntos
Aorta , Hemodinâmica , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Velocidade do Fluxo Sanguíneo , Valores de Referência , Voluntários Saudáveis , Estresse Mecânico
2.
Rofo ; 196(3): 273-282, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37944940

RESUMO

PURPOSE: To utilize 4 D flow MRI to acquire normal values of "conventional 2 D flow MRI parameters" in healthy volunteers in order to replace multiple single 2 D flow measurements with a single 4 D flow acquisition. MATERIALS AND METHODS: A kt-GRAPPA accelerated 4 D flow sequence was used. Flow volumes were assessed by forward (FFV), backward (BFV), and net flow volumes (NFV) [ml/heartbeat] and flow velocities by axial (VAX) and absolute velocity (VABS) [m/s] in 116 volunteers (58 females, 43 ±â€Š13 years). The aortic regurgitant fraction (RF) was calculated. RESULTS: The sex-neutral mean FFV, BFV, NFV, and RF in the ascending aorta were 93.5 ±â€Š14.8, 3.6 ±â€Š2.8, 89.9 ±â€Š0.6 ml/heartbeat, and 3.9 ±â€Š2.9 %, respectively. Significantly higher values were seen in males regarding FFV, BFV, NFV and RF, but there was no sex dependency regarding VAX and VABS. The mean maximum VAX was lower (1.01 ±â€Š0.31 m/s) than VABS (1.23 ±â€Š0.35 m/s). We were able to determine normal ranges for all intended parameters. CONCLUSION: This study provides quantitative 4 D flow-derived thoracic aortic normal values of 2 D flow parameters in healthy volunteers. FFV, BFV, NFV, and VAX did not differ significantly from single 2 D flow acquisitions and could therefore replace time-consuming multiple single 2 D flow acquisitions. VABS should not be used interchangeably. KEY POINTS: · 4 D flow MRI can be used to replace 2 D flow MRI measurements.. · The parameter absolute velocities can be assessed by 4 D flow MRI.. · There are sex-dependent differences regarding forward, backward, net aortic blood flow and the aortic valve regurgitant fraction..


Assuntos
Aorta , Imageamento por Ressonância Magnética , Masculino , Feminino , Humanos , Valores de Referência , Voluntários Saudáveis , Velocidade do Fluxo Sanguíneo/fisiologia , Aorta/diagnóstico por imagem , Imageamento Tridimensional , Reprodutibilidade dos Testes , Aorta Torácica/diagnóstico por imagem
3.
Quant Imaging Med Surg ; 13(12): 7973-7986, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38106267

RESUMO

Background: The rotational direction (RD) of helical blood flow can be classified as either a clockwise (RD+) or counter-clockwise (RD-) flow. We hypothesized that this simple classification might not be sufficient for analysis in vivo and a simultaneous existence of RD+/- may occur. We utilized volumetric velocity-sensitive cardiovascular magnetic resonance imaging (4D flow MRI) to analyze rotational blood flow in the thoracic aorta. Methods: Forty volunteers (22 females; mean age, 41±16 years) and seventeen patients with bicuspid aortic valves (BAVs) (9 females; mean age, 42±14 years) were prospectively included. The RDs and the calculation of the rotating blood volumes (RBVs) in the thoracic aorta were performed using a pathline-projection strategy. Results: We could confirm a mainly clockwise RD in the ascending, descending aorta and in the aortic arch. Furthermore, we found a simultaneous existence of RD+/RD-. The RD+/--volume in the ascending aorta was significantly higher in BAV patients, the mean RD+/RD- percentage was approximately 80%/20% vs. 60%/40% in volunteers (P<0.01). The maximum RBV always occurred during systole. There was significantly more clockwise than counter-clockwise rotational flow in the ascending aorta (P<0.01) and the aortic arch (P<0.01), but no significant differences in the descending aorta (P=0.48). Conclusions: A simultaneous occurrence of RD+/RD- indicates that a simple categorization in either of both is insufficient to describe blood flow in vivo. Rotational flow in the ascending aorta and in the aortic arch differs significantly from flow in the descending aorta. BAV patients show significantly more clockwise rotating volume in the ascending aorta compared to healthy volunteers.

4.
Sci Rep ; 10(1): 2949, 2020 02 19.
Artigo em Inglês | MEDLINE | ID: mdl-32076060

RESUMO

4D flow MRI enables quantitative assessment of helical flow. Current methods are susceptible to noise. To evaluate helical flow patterns in healthy volunteers and patients with bicuspid aortic valves (BAV) at 1.5 T and 3 T using pressure-based helix-extraction in 4D flow MRI. Two intraindividual 4D flow MRI examinations were performed at 1.5 T and 3 T in ten healthy volunteers (5 females, 32 ± 3 years) and 2 patients with BAV using different acceleration techniques (kt-GRAPPA and centra). Several new quantitative parameters for the evaluation of volumes [ml], lengths [mm] as well as temporal parameters [ms] of helical flow were introduced and analyzed using the software tool Bloodline. We found good correlations between measurements in volunteers at 1.5 T and 3 T regarding helical flow volumes (R = 0.98) and temporal existence (R = 0.99) of helices in the ascending aorta. Furthermore, we found significantly larger (11.7 vs. 77.6 ml) and longer lasting (317 vs. 769 ms) helices in patients with BAV than in volunteers. The assessed parameters do not depend on the magnetic field strength used for the acquisition. The technique of pressure-based extraction of 4D flow MRI pattern is suitable for differentiation of normal and pathological flow.


Assuntos
Aorta/diagnóstico por imagem , Imageamento por Ressonância Magnética , Fluxo Sanguíneo Regional/fisiologia , Adulto , Automação , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Adulto Jovem
5.
Eur Radiol Exp ; 3(1): 10, 2019 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-30806827

RESUMO

BACKGROUND: Four-dimensional (4D) flow magnetic resonance imaging (MRI) sequences with advanced parallel imaging have the potential to reduce scan time with equivalent image quality and accuracy compared with standard two-dimensional (2D) flow MRI. We compared 4D flow to standard 2D flow sequences using a constant and pulsatile flow phantom at 3 T. METHODS: Two accelerated 4D flow sequences (GRAPPA2 and k-t-GRAPPA5) were evaluated regarding the concordance of flow volumes, flow velocities, and reproducibility as well as dependency on measuring plane and velocity encoding (Venc). The calculated flow volumes and peak velocities of the phantom were used as reference standard. Flow analysis was performed using the custom-made software "Bloodline". RESULTS: No significant differences in flow volume were found between the 2D, both 4D flow MRI sequences, and the pump reference (p = 0.994) or flow velocities (p = 0.998) in continuous and pulsatile flow. An excellent correlation (R = 0.99-1.0) with a reference standard and excellent reproducibility of measurements (R = 0.99) was achieved for all sequences. A Venc overestimated by up to two times had no impact on flow measurements. However, misaligned measuring planes led to an increasing underestimation of flow volume and mean velocity in 2D flow accuracy, while both 4D flow measurements were not affected. Scan time was significantly shorter for k-t-GRAPPA5 (1:54 ± 0:01 min, mean ± standard deviation) compared to GRAPPA2 (3:56 ± 0:02 min) (p = 0.002). CONCLUSIONS: Both 4D flow sequences demonstrated equal agreement with 2D flow measurements, without impact of Venc overestimation and plane misalignment. The highly accelerated k-t-GRAPPA5 sequence yielded results similar to those of GRAPPA2.

6.
Sci Rep ; 9(1): 8643, 2019 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-31201339

RESUMO

To compare two broadly used 4D-flow- with a 2D-flow-sequence in healthy volunteers, regarding absolute flow parameters, image quality (IQ), and eddy current correction (ECC). Forty volunteers (42 ± 11.8 years, 22 females) were examined with a 3T scanner. Thoracic aortic flow was assessed using a 3D-T2w-SPACE-STIR-sequence for morphology and two accelerated 4D-flow sequences for comparison, one with k-t undersampling and one with standard GRAPPA parallel-imaging. 2D-flow was used as reference standard. The custom-made software tool Bloodline enabled flow measurements for all analyses at the same location. Quantitative flow analyses were performed with and without ECC. One reader assessed pathline IQ (IQ-PATH) and occurrence of motion artefacts (IQ-ART) on a 3-point grading scale, the higher the better. k-t GRAPPA allowed a significant mean scan time reduction of 46% (17:56 ± 5:26 min vs. 10:40 ± 3:15 min) and provided significantly fewer motion artefacts than standard GRAPPA (IQ-ART 1.57 ± 0.55 vs. 0.84 ± 0.48; p < 0.001). Neither 4D-flow sequence significantly differed in flow volume nor peak velocity results with or without ECC. Nevertheless, the correlation between both 4D-flow sequences and 2D-flow was better with ECC; the k-t GRAPPA sequence performed best (R = 0.96 vs. 0.90). k-t GRAPPA 4D-flow was not inferior to a standard GRAPPA-sequence, showed fewer artefacts, comparable IQ and was almost two-fold faster.


Assuntos
Aorta/fisiologia , Circulação Coronária/fisiologia , Adulto , Artefatos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Reprodutibilidade dos Testes , Sístole/fisiologia , Fatores de Tempo
7.
Exp Clin Endocrinol Diabetes ; 126(9): 570-576, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29183104

RESUMO

AIMS: We examined prevalence and progression of retinopathy in dependence on diabetes duration in order to estimate the probability of progression. PATIENTS/METHODS: In a retrospective cohort-analysis from an academic outpatient department of endocrinology and metabolic diseases we analyzed 17461 consultations of 4513 patients with DM2 from 1987 to 2014. 50.3% of the patients (n=2272) had at least one documented result of funduscopy. RESULTS: 25.8% of the patients had retinopathy (20.2% non-proliferative, 4.7% proliferative, 0.7% were not classified, 0.1% blindness). The prevalence of retinopathy in dependence on diabetes duration was 1.1% at diagnosis, 6.6% after 0<5 years, 12% after 5<10 years, 24% after 10<15 years, 39.9% after 15<20 years, 52.7% after 20<25 years, 58.7% after 25<30 years and 63% after ≥30 years. In a subset of 586 (25.7%) patients with retinal photography of 3 consecutive years 7.0% showed deterioration after one and 12.2% after two years; 2.6% improved after one and 2.8% after two years. 201 (34.3%) of this group had<10 years diabetes and lower deterioration (4.5% worsened after one and 9.5% after two years). Their retinopathy mainly transformed from no retinopathy to non-proliferative. Four patients (2.0%) developed proliferative retinopathy. CONCLUSIONS/INTERPRETATIONS: Within the first 10 years of diabetes duration, the prevalence of retinopathy is low and the progression infrequent. Most patients have a non-proliferative form which can be reversible and rarely requires interventions. Patients with DM2 without retinopathy and good glycaemic control do not run into additional risk from expanding funduscopy intervals to biennial.


Assuntos
Diabetes Mellitus Tipo 2/epidemiologia , Retinopatia Diabética/epidemiologia , Progressão da Doença , Retinoscopia/estatística & dados numéricos , Idoso , Diabetes Mellitus Tipo 2/complicações , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estudos Retrospectivos , Fatores de Tempo
8.
Int J Comput Assist Radiol Surg ; 11(2): 169-79, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26183147

RESUMO

PURPOSE: 4D PC-MRI enables the noninvasive measurement of time-resolved, three-dimensional blood flow data that allow quantification of the hemodynamics. Stroke volumes are essential to assess the cardiac function and evolution of different cardiovascular diseases. The calculation depends on the wall position and vessel orientation, which both change during the cardiac cycle due to the heart muscle contraction and the pumped blood. However, current systems for the quantitative 4D PC-MRI data analysis neglect the dynamic character and instead employ a static 3D vessel approximation. We quantify differences between stroke volumes in the aorta obtained with and without consideration of its dynamics. METHODS: We describe a method that uses the approximating 3D segmentation to automatically initialize segmentation algorithms that require regions inside and outside the vessel for each temporal position. This enables the use of graph cuts to obtain 4D segmentations, extract vessel surfaces including centerlines for each temporal position and derive motion information. The stroke volume quantification is compared using measuring planes in static (3D) vessels, planes with fixed angulation inside dynamic vessels (this corresponds to the common 2D PC-MRI) and moving planes inside dynamic vessels. RESULTS: Seven datasets with different pathologies such as aneurysms and coarctations were evaluated in close collaboration with radiologists. Compared to the experts' manual stroke volume estimations, motion-aware quantification performs, on average, 1.57% better than calculations without motion consideration. The mean difference between stroke volumes obtained with the different methods is 7.82%. Automatically obtained 4D segmentations overlap by 85.75% with manually generated ones. CONCLUSION: Incorporating motion information in the stroke volume quantification yields slight but not statistically significant improvements. The presented method is feasible for the clinical routine, since computation times are low and essential parts run fully automatically. The 4D segmentations can be used for other algorithms as well. The simultaneous visualization and quantification may support the understanding and interpretation of cardiac blood flow.


Assuntos
Algoritmos , Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Humanos , Movimento (Física)
9.
IEEE Trans Vis Comput Graph ; 19(12): 2773-82, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24051844

RESUMO

Cardiovascular diseases (CVD) are the leading cause of death worldwide. Their initiation and evolution depends strongly on the blood flow characteristics. In recent years, advances in 4D PC-MRI acquisition enable reliable and time-resolved 3D flow measuring, which allows a qualitative and quantitative analysis of the patient-specific hemodynamics. Currently, medical researchers investigate the relation between characteristic flow patterns like vortices and different pathologies. The manual extraction and evaluation is tedious and requires expert knowledge. Standardized, (semi-)automatic and reliable techniques are necessary to make the analysis of 4D PC-MRI applicable for the clinical routine. In this work, we present an approach for the extraction of vortex flow in the aorta and pulmonary artery incorporating line predicates. We provide an extensive comparison of existent vortex extraction methods to determine the most suitable vortex criterion for cardiac blood flow and apply our approach to ten datasets with different pathologies like coarctations, Tetralogy of Fallot and aneurysms. For two cases we provide a detailed discussion how our results are capable to complement existent diagnosis information. To ensure real-time feedback for the domain experts we implement our method completely on the GPU.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Circulação Coronária , Cardiopatias/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA