Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Med Imaging ; 24(1): 145, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872126

RESUMO

BACKGROUND: To compare the diagnostic value of 120-kV with conventional 96-kV Cone-Beam CT (CBCT) of the temporal bone after cochlear implant (CI) surgery. METHODS: This retrospective study included CBCT scans after CI surgery between 06/17 and 01/18. CBCT allowed examinations with 96-kV or 120-kV; other parameters were the same. Two radiologists independently evaluated following criteria on 5-point Likert scales: osseous spiral lamina, inner and outer cochlear wall, semi-circular canals, mastoid trabecular structure, overall image quality, metal and motion artefacts, depiction of intracochlear electrode position and visualisation of single electrode contacts. Effective radiation dose was assessed. RESULTS: Seventy-five patients (females, n = 39 [52.0%], mean age, 55.8 ± 16.5 years) were scanned with 96-kV (n = 32, 42.7%) and 120-kV (n = 43, 57.3%) protocols including CI models from three vendors (vendor A n = 7; vendor B n = 43; vendor C n = 25). Overall image quality, depiction of anatomical structures, and electrode position were rated significantly better in 120-kV images compared to 96-kV (all p < = 0.018). Anatomical structures and electrode position were rated significantly better in 120-kV CBCT for CI models from vendor A and C, while 120-kV did not provide improved image quality in CI models from vendor B. Radiation doses were significantly higher for 120-kV scans compared to 96-kV (0.15 vs. 0.08 mSv, p < 0.001). CONCLUSIONS: 120-kV and 96-kV CBCT provide good diagnostic images for the postoperative CI evaluation. While 120-kV showed improved depiction of temporal bone and CI electrode position compared to 96-kV in most CI models, the 120-kV protocol should be chosen wisely due to a substantially higher radiation exposure.


Assuntos
Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Doses de Radiação , Osso Temporal , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Osso Temporal/diagnóstico por imagem , Idoso , Adulto , Implante Coclear/métodos
2.
NMR Biomed ; 36(2): e4828, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36082477

RESUMO

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Imagem Corporal Total , Fluxo de Trabalho
3.
AJR Am J Roentgenol ; 216(3): 752-758, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33439050

RESUMO

OBJECTIVE. The purpose of this article is to evaluate subjective image quality and diagnostic accuracy to determine cochlear implant (CI) electrode position in a temporal bone (TB) specimen on cone-beam CT (CBCT) versus MDCT. MATERIALS AND METHODS. In this retrospective study, two radiologists independently reviewed CBCT (96-kV and 120-kV settings) and MDCT images of 20 TB specimens after electrode implantation. Qualitative evaluation of bone structures of the otic capsule, inner and outer cochlear wall, osseous spiral lamina, electrode position relative to the osseous spiral lamina, visualization of single electrode contacts on the array, metal artifacts, and overall image quality was performed using a five-point scale. Intracochlear electrode position was subsequently correlated with histologic examination. RESULTS. Radiologic assessment of bone structures of the otic capsule, the cochlear wall (except the outer part), osseous spiral lamina, electrode position, visualization of single electrode contacts on the array, metal artifacts, and overall image quality were significantly higher in CBCT compared with MDCT (maximum p = .04). No significant differences were found between CBCT at 96 kV and 120 kV (minimum p = .21). The intracochlear electrode position with histologic correlation was correctly diagnosed in 100% and 97.5% of specimens on 120-kV and 96-kV CBCT, respectively, whereas 77.5% were correctly assessed using MDCT. CONCLUSION. The data suggest that CBCT shows a higher diagnostic accuracy in TB specimen imaging after CI compared with MDCT, in particular to determine the intracochlear localization of the implant.


Assuntos
Implante Coclear , Implantes Cocleares , Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Multidetectores , Osso Temporal/diagnóstico por imagem , Humanos , Doses de Radiação , Estudos Retrospectivos
4.
Eur Radiol ; 30(12): 6757-6769, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32676784

RESUMO

OBJECTIVES: To analyze the performance of radiological assessment categories and quantitative computational analysis of apparent diffusion coefficient (ADC) maps using variant machine learning algorithms to differentiate clinically significant versus insignificant prostate cancer (PCa). METHODS: Retrospectively, 73 patients were included in the study. The patients (mean age, 66.3 ± 7.6 years) were examined with multiparametric MRI (mpMRI) prior to radical prostatectomy (n = 33) or targeted biopsy (n = 40). The index lesion was annotated in MRI ADC and the equivalent histologic slides according to the highest Gleason Grade Group (GrG). Volumes of interest (VOIs) were determined for each lesion and normal-appearing peripheral zone. VOIs were processed by radiomic analysis. For the classification of lesions according to their clinical significance (GrG ≥ 3), principal component (PC) analysis, univariate analysis (UA) with consecutive support vector machines, neural networks, and random forest analysis were performed. RESULTS: PC analysis discriminated between benign and malignant prostate tissue. PC evaluation yielded no stratification of PCa lesions according to their clinical significance, but UA revealed differences in clinical assessment categories and radiomic features. We trained three classification models with fifteen feature subsets. We identified a subset of shape features which improved the diagnostic accuracy of the clinical assessment categories (maximum increase in diagnostic accuracy ΔAUC = + 0.05, p < 0.001) while also identifying combinations of features and models which reduced overall accuracy. CONCLUSIONS: The impact of radiomic features to differentiate PCa lesions according to their clinical significance remains controversial. It depends on feature selection and the employed machine learning algorithms. It can result in improvement or reduction of diagnostic performance. KEY POINTS: • Quantitative imaging features differ between normal and malignant tissue of the peripheral zone in prostate cancer. • Radiomic feature analysis of clinical routine multiparametric MRI has the potential to improve the stratification of clinically significant versus insignificant prostate cancer lesions in the peripheral zone. • Certain combinations of standard multiparametric MRI reporting and assessment categories with feature subsets and machine learning algorithms reduced the diagnostic performance over standard clinical assessment categories alone.


Assuntos
Imagem de Difusão por Ressonância Magnética , Aprendizado de Máquina , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Área Sob a Curva , Biópsia , Análise por Conglomerados , Humanos , Masculino , Pessoa de Meia-Idade , Análise de Componente Principal , Próstata/diagnóstico por imagem , Prostatectomia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Máquina de Vetores de Suporte , Resultado do Tratamento
5.
Eur Radiol ; 29(5): 2553-2559, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30547199

RESUMO

OBJECTIVES: Increasing awareness of potential side effects from gadolinium-based contrast agents has underlined the need for contrast-free magnetic resonance imaging (MRI). Numerous recent articles evaluated the risk of potential brain deposits, with the result that research is putting the focus more on alternative unenhanced imaging techniques. The aim of this study was to determine the need for contrast media for chest MRI in primary staging and follow-up care of lymphoma. METHODS: This monocentric, retrospective study encompassed patients under 25 years of age who had undergone histopathological examination of thoracic lymph nodes and at least one chest MRI examination with unenhanced and contrast-enhanced sequences. Seven different thoracic lymph node stations including mediastinal, hilar, periclavicular, and axillary regions were evaluated by two readers regarding lesion diameter, number, shape, necrosis, and infiltration of surrounding structures. Findings were categorized into suspicious (> 1 cm; round; necrosis; infiltration) or non-suspicious. RESULTS: Fifty-one patients (mean age, 16.0 ± 3.7 yrs) with thoracic Hodgkin (70.6%) and non-Hodgkin lymphoma (25.5%) and lymphadenopathy (3.9%) were retrospectively included. Most lymph nodes categorized as suspicious were located in the mediastinal station (86.4%). High agreement (κ = 0.81) between unenhanced and contrast-enhanced sequences was found for both suspicious and non-suspicious lymph nodes. Significant (p < 0.001), but small difference (1 mm) was observed only in sizing mediastinal lymph nodes (all other p > 0.05). No significant difference (smallest p = 0.08) was shown for the use of five different types of contrast media. CONCLUSION: MRI in young patients with thoracic lymphoma can safely be done without the use of contrast agent. KEY POINT: • Thoracic magnetic resonance imaging in young lymphoma patients can safely be done without gadolinium-based contrast agents.


Assuntos
Linfoma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Compostos Organometálicos/farmacologia , Neoplasias Torácicas/diagnóstico , Adolescente , Adulto , Criança , Pré-Escolar , Meios de Contraste/farmacologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
6.
Eur Radiol ; 29(12): 6539-6549, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31236701

RESUMO

OBJECTIVES: To evaluate the diagnostic value of Lipiodol distribution in angiography and CT to differentiate between hepatocellular carcinoma (HCC) and benign nodules of LI-RADS 3 and 4 lesions observed in MRI of liver cirrhosis. METHODS: This retrospective study included all patients with liver cirrhosis who had diagnosis of LI-RADS 3 or 4 lesions by MRI who underwent a Lipiodol-based angiography and post-interventional unenhanced CT- and liver biopsy. Two independent radiologists evaluated appearance, contrast enhancement, Lipiodol uptake in angiography, and morphological parameters (size, form, and density) of the lesions in unenhanced post-angiography CT. α-Fetoprotein (AFP) levels and pre-existing liver conditions were additionally taken into consideration. Differences between HCC lesions and benign nodules were analyzed. Sensitivity and specificity were calculated. P < 0.05 was considered as statistically significant. RESULTS: Of 60 patients (men, n = 42 [70.0%]; women, 18 [30.0%]; mean age, 61 ± 9.1 years) 36 (60.0%) had HCC and 24 (40.0%) benign nodules. Clear visibility in angiography (sensitivity [se], 100%; specificity [sp], 87.5%) with homogeneous or lacunar Lipiodol enhancement (se, 86.1%; sp, 100%) in consecutive CT can be diagnosed as HCC lesions in cirrhotic liver. Lesion form (p < 0.001), round or oval, and intense contrast (p < 0.001) are minor features which can facilitate the findings. Furthermore, patients with HCC showed a larger lesion size in CT (p = 0.026). CONCLUSION: Clearly detectable lesions in Lipiodol-based angiography and a homogeneous or lacunar enhancement in post-angiographic non-contrast CT allow for differentiation of intrahepatic lesions classified as LI-RADS 3 or 4 into benign vs. malign liver lesions with high sensitivity and specificity in patients with liver cirrhosis. Definite diagnosis may not require an additional biopsy. KEY POINTS: • Combination of clear visibility in Lipiodol-based angiography and homogeneous or lacunar enhancement in following native CT scan is HCC-defining. • In lesions classified with MRI as LI-RADS 3 or 4, evaluation based on Lipiodol angiography and following plain CT performed is highly sensitive and specific for the differentiation between HCC and benign nodules in a cirrhotic liver. • The results lead to an alternative pathway in the diagnosis of HCC in cirrhotic liver without the need of an additional liver biopsy.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste/farmacocinética , Óleo Etiodado/farmacocinética , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Angiografia/métodos , Carcinoma Hepatocelular/complicações , Carcinoma Hepatocelular/patologia , Feminino , Humanos , Cirrose Hepática/complicações , Cirrose Hepática/patologia , Neoplasias Hepáticas/complicações , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
AJR Am J Roentgenol ; 213(6): 1388-1396, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31593520

RESUMO

OBJECTIVE. The objective of our study was to evaluate the clinical performance of a new high-frequency (HF) microwave ablation (MWA) technology with spatial energy control for treatment of lung malignancies in comparison with a conventional low-frequency (LF) MWA technology. MATERIALS AND METHODS. In this retrospective study, 59 consecutive patients (mean age, 58.9 ± 12.6 [SD] years) were treated in 71 sessions using HF spatial-energy-control MWA. Parameters collected were technical success and efficacy, tumor diameter, tumor and ablation volumes, ablation time, output energy, complication rate, 90-day mortality, local tumor progression (LTP), ablative margin size, and ablation zone sphericity. Results were compared with the same parameters retrospectively collected from the last 71 conventional LF-MWA sessions. This group consisted of 56 patients (mean age, 60.3 ± 10.8 years). Statistical comparisons were performed using the Wilcoxon-Mann-Whitney test. RESULTS. Technical success was 98.6% for both technologies; technical efficacy was 97.2% for HF spatial-energy-control MWA and 95.8% for LF-MWA. The 90-day mortality rate was 5.1% (3/59) in the HF spatial-energy-control MWA group and 5.4% (3/56) in the LF-MWA group; for both groups, there were zero intraprocedural deaths. The median ablation time was 8.0 minutes for HF spatial-energy-control MWA and 10.0 minutes for LF-MWA (p < 0.0001). Complications were recorded in 21.1% (15/71) of HF spatial-energy-control MWA sessions and in 31.0% (22/71) of LF-MWA sessions (p = 0.182); of these complications, 4.2% (3/71) were major complications in the HF spatial-energy-control MWA group, and 9.9% (7/71) were major complications in the LF-MWA group. The median deviation from ideal sphericity (1.0) was 0.195 in the HF spatial-energy-control MWA group versus 0.376 in the LF-MWA group (p < 0.0001). Absolute minimal ablative margins per ablation were 7.5 ± 3.6 mm (mean ± SD) in the HF spatial-energy-control MWA group versus 4.2 ± 3.0 mm in the LF-MWA group (p < 0.0001). In the HF spatial-energy-control MWA group, LTP at 12 months was 6.5% (4/62). LTP at 12 months in the LF-MWA group was 12.5% (7/56). Differences in LTP rate (p = 0.137) and time point (p = 0.833) were not significant. CONCLUSION. HF spatial-energy-control MWA technology and conventional LFMWA technology are safe and effective for the treatment of lung malignancies independent of the MWA system used. However, HF spatial-energy-control MWA as an HF and high-energy MWA technique achieves ablation zones that are closer to an ideal sphere and achieves larger ablative margins than LF-MWA (p < 0.0001).


Assuntos
Técnicas de Ablação/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Micro-Ondas/uso terapêutico , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Meios de Contraste , Progressão da Doença , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Estudos Retrospectivos
8.
J Comput Assist Tomogr ; 43(1): 39-45, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30119064

RESUMO

OBJECTIVE: The aim of this study was to investigate a novel version of a computer-aided diagnosis (CAD) system developed for automated bone age (BA) assessment in comparison to the Greulich and Pyle method, regarding its accuracy and the influence of carpal bones on BA assessment. METHODS: Total BA, BA of the left distal radius, and BA of carpal bones in 305 patients were determined independently by 3 blinded radiologists and assessed by the CAD system. Pearson product-moment correlation, Bland-Altman plot, root-mean-square deviation, and further agreement analyses were computed. RESULTS: Mean total BA and BA of the distal radius showed high correlation between both approaches (r = 0.985 and r = 0.963). There was significantly higher correlation between values of total BA and BA of the distal radius (r = 0.969) compared with values of total BA and BA of carpal bones (r = 0.923). The assessment of carpal bones showed significantly lower interreader agreement compared with measurements of the distal radius (κ = 0.79 vs κ = 0.98). CONCLUSION: A novel version of a CAD system enables highly accurate automated BA assessment. The assessment of carpal bones revealed lower precision and interreader agreement. Therefore, methods determining BA without analyzing carpal bones may be more precise and accurate.


Assuntos
Determinação da Idade pelo Esqueleto/métodos , Ossos do Carpo/diagnóstico por imagem , Diagnóstico por Computador/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Mãos/diagnóstico por imagem , Humanos , Lactente , Masculino , Radiografia/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Punho/diagnóstico por imagem
9.
Int J Hyperthermia ; 34(6): 883-890, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-28877612

RESUMO

PURPOSE: To retrospectively investigate the role of a contrast enhanced MRI (ceMRI) performed 24 h after a microwave ablation (MWA) of the lung, in predicting local tumour progression (LTP) and detecting complications compared to an unenhanced CT. MATERIAL AND METHODS: Forty-nine patients who underwent MWA of 77 lung metastases between 2008 and 2015 were included. All patients received an unenhanced chest CT and a ceMRI (including T2 and ceT1) 24 h after MWA. The conspicuities of the peripheral rim and the ablated tumour were scored using 1-3 scales and compared between examinations. The safety margin was measured directly (both scores ≥2) and indirectly using a subtraction method. The ability of each imaging modality to predict LTP based on safety margin width was analysed using receiver operating characteristic curves. The MRI ability to detect a pneumothorax was compared to CT. RESULTS: The peripheral rim was best visualised on T2 followed by T1 and CT. The tumour was best visualised on CT, followed by T1 and T2. Direct safety margin measurement was possible on CT, ceT1 and T2 in 68.8%, 64.9% and 27.3% of cases, respectively. Direct CT (AUC = 0.77) and ceT1 (AUC = 0.76) measurements had better diagnostic performance than indirect CT (AUC = 0.72), ceT1 (AUC = 0.70) and T2 (AUC = 0.69) measurements. The MRI sensitivity and specificity for pneumothorax were 60.8% and 87.0%, respectively. Only one pneumothorax >1 cm was missed. CONCLUSIONS: A ceMRI performed 24 h after MWA of lung tumours has a similar ability to predict LTP and detect important complications as a CT has.


Assuntos
Ablação por Cateter/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Micro-Ondas/uso terapêutico , Feminino , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Masculino , Estudos Retrospectivos
10.
Int J Hyperthermia ; 34(4): 492-500, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28774210

RESUMO

OBJECTIVES: To evaluate the clinical performance of a new microwave ablation (MWA) system with enabled constant spatial energy control (ECSEC) to achieve spherical ablation zones in the treatment of liver malignancies. MATERIALS AND METHODS: In this retrospective study, 56 hepatic tumours in 48 patients (23 men, 25 women; mean age: 59.6 years) were treated using a new high-frequency MWA-system with ECSEC. Parameters evaluated were technical success, technical efficacy, tumour diameter, tumour and ablation volume, complication rate, 90-day mortality, local tumour progression (LTP) at the 12-month follow-up, ablative margin and ablation zone sphericity. These parameters were compared using the Kruskal-Wallis test with the same parameters collected retrospectively from cohorts of patients treated with conventional high-frequency (HF) MWA (n = 20) or low-frequency (LF) MWA (n = 20). RESULTS: Technical success was achieved in all interventions. The technical efficacy was 100% (ECSEC) vs. 100% (LF-MWA) vs. 95% (HF-MWA). There were no intra-procedural deaths or major complications. Minor complications occurred in 3.57% (2/56), 0% (0/20) and 0% (0/20) of the patients, respectively. The one-year mortality rate was 16.1% (9/56), 15% (3/20) and 10% (2/20), respectively. The LTP was 3.57% (2/56), 5% (1/20) and 5% (1/20), respectively. The median deviation from ideal sphericity (1.0) was 0.135 (ECSEC) vs. 0.344 (LF-MWA) vs. 0.314 (HF-MWA) (p < 0.001). The absolute minimal ablative margin was 8.1 vs. 2.3 vs. 3.1 mm (p < 0.001). CONCLUSIONS: Microwave ablation of liver malignancies is a safe and efficient treatment independent of the system used. Hepatic MWA with ECSEC achieves significantly more spherical ablation zones and higher minimal ablative margins.


Assuntos
Técnicas de Ablação/métodos , Neoplasias Hepáticas/cirurgia , Micro-Ondas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Carga Tumoral
11.
Int J Hyperthermia ; 33(7): 820-829, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28540791

RESUMO

PURPOSE: To retrospectively compare the local tumour response and survival rates in patients with non-colorectal cancer lung metastases post-ablation therapy using laser-induced thermotherapy (LITT), radiofrequency ablation (RFA) and microwave ablation (MWA). MATERIAL AND METHODS: Retrospective analysis of 175 computed tomography (CT)-guided ablation sessions performed on 109 patients (43 males and 66 females, mean age: 56.6 years). Seventeen patients with 22 lesions underwent LITT treatment (tumour size: 1.2-4.8 cm), 29 patients with 49 lesions underwent RFA (tumour size: 0.8-4.5 cm) and 63 patients with 104 lesions underwent MWA treatment (tumour size: 0.6-5 cm). CT scans were performed 24-h post-therapy and on follow-up at 3, 6, 12, 18 and 24 months. RESULTS: The overall-survival rates at 1-, 2-, 3- and 4-year were 93.8, 56.3, 50.0 and 31.3% for patients treated with LITT; 81.5, 50.0, 45.5 and 24.2% for patients treated with RFA and 97.6, 79.9, 62.3 and 45.4% for patients treated with MWA, respectively. The mean survival time was 34.14 months for MWA, 34.79 months for RFA and 35.32 months for LITT. In paired comparison, a significant difference could be detected between MWA versus RFA (p = 0.032). The progression-free survival showed a median of 23.49 ± 0.62 months for MWA,19.88 ± 2.17 months for LITT and 16.66 ± 0.66 months for RFA (p = 0.048). The lowest recurrence rate was detected in lesions ablated with MWA (7.7%; 8 of 104 lesions) followed by RFA (20.4%; 10 of 49 lesions) and LITT (27.3%; 6 of 22 lesions) p value of 0.012. Pneumothorax was detected in 22.16% of MWA ablations, 22.73% of LITT ablations and 14.23% of RFA ablations. CONCLUSION: LITT, RFA and MWA may provide an effective therapeutic option for non-colorectal cancer lung metastases with an advantage for MWA regarding local tumour control and progression-free survival rate.


Assuntos
Ablação por Cateter , Hipertermia Induzida , Neoplasias Pulmonares/terapia , Micro-Ondas , Adulto , Idoso , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Tomografia Computadorizada por Raios X
12.
Radiol Manage ; 39(1): 17-21, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30725545

RESUMO

The purpose of this work was a cost analysis for the acquisition of two new MRI devices in a university hospital. The costs of a classical exchange (new purchase) were compared to those of a system upgrade. Taking the local circumstances into account, up to $121,000 could be saved with. the system upgrade for one MRI system compared to a classic exchange. Upgrades of the 1.5 and 3 Tesla systems were performed within 15 working days without any problems or restrictions. The number of examinations per day could be increased from 13.4 to 16.2 using the 1.5T system and from 14.1 to 15.9 using the 3T. The upgrade possibility of an old MRI device represents an economically attractive approach, which allows access to the latest state-of-the-art MRI technology while respecting the limited economic resources of the department.


Assuntos
Gastos de Capital/estatística & dados numéricos , Administração Financeira de Hospitais/métodos , Imageamento por Ressonância Magnética/instrumentação , Custos e Análise de Custo , Eficiência Organizacional , Alemanha , Arquitetura Hospitalar , Humanos , Estudos de Casos Organizacionais
13.
Int J Hyperthermia ; 32(7): 757-64, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27436220

RESUMO

PURPOSE: Computed tomography (CT) and ultrasound-guided microwave ablations (MWA) are part of the established treatment of liver tumours. In spite of its potential advantages, magnetic resonance (MR) monitoring of MWA did not enter clinical practice because of the lack of compatible devices. The purpose of the current study was to prove the feasibility of real-time qualitative MR monitoring using a new MR-compatible MWA device. MATERIAL AND METHODS: We performed 27 MWA experiments with different durations (5, 10 and 15 min) on an ex vivo bovine liver model using a MR-compatible MWA device. We compared the diameters of the ablation zone as depicted on three T1-based sequences to those of the macroscopic specimen. The volume and the sphericity index of the macroscopic ablation area were calculated in order to characterise the device. Ablation pattern and artefacts on the three sequences were also taken into account. RESULTS: We obtained high-quality real-time images using all three sequences. The diameters as depicted on the MR sequences slightly overestimated the macroscopic ablation area but correlated significantly in all cases (p < 0.05). VIBE provided the best correlation for both short-axis diameter (r = 0.96) and long-axis diameter (r = 0.87), whereas starVIBE (r = 0.85; r = 0.72) and FLASH (r = 0.75; r = 0.84) correlated slightly less. Significantly more severe noise artefacts were observed on starVIBE compared to FLASH and VIBE sequences (p < 0.0001). CONCLUSION: The current ex vivo liver model experiment suggests that real-time qualitative MR monitoring of MWA is feasible. Further research using in vivo and human models are recommended.


Assuntos
Técnicas de Ablação/métodos , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Micro-Ondas/uso terapêutico , Animais , Ablação por Cateter/métodos , Bovinos , Humanos
14.
Catheter Cardiovasc Interv ; 86(2): 299-303, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23983010

RESUMO

BACKGROUND: Catheter-based renal sympathetic denervation (RD) causes significant blood pressure (BP) reductions in patients with resistant hypertension (rHTN). However, hypertensive elderly patients reportedly have a lower sympathetic tone than younger patients and a BP lowering effect of RD in this population has not yet been demonstrated. The purpose of this study was to assess the efficacy and safety of RD in elderly patients. METHODS: We reviewed all consecutive patients aged ≥ 75 years (mean: 78 years) with rHTN treated with RD. Twenty-four patients were included in this prospective study. Office and ambulatory BPs were assessed at baseline and 6-months follow-up. Primary endpoint was the change in office systolic BP at 6 months. RESULTS: Baseline mean office BP was 173/86 ± 21/13 mm Hg. Baseline 24-hr mean ambulatory BP, available in 22 patients, was 158/80 ± 20/13 mm Hg. Baseline creatinine was 1.0 ± 0.18 mg/dl and mean number of antihypertensive agents at baseline 4.3 ± 1.4. No device- or procedure-related adverse events occurred. At 6-months follow-up, the mean office BP decreased by 19/11 ± 29/16 mm Hg (P < 0.01 compared to baseline). Mean systolic 24 hr ambulatory BP, available in 17 patients, decreased by 9/5 ± 13/13 mm Hg. Antihypertensive medications could be reduced in nine patients. Furthermore, renal function was not impaired. CONCLUSION: According to our findings, a similar magnitude of BP reduction as reported in previous trials can be expected in elderly patients. Elderly patients with rHTN should not be excluded from renal denervation.


Assuntos
Pressão Sanguínea , Ablação por Cateter , Hipertensão/cirurgia , Rim/irrigação sanguínea , Artéria Renal/cirurgia , Simpatectomia/métodos , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Estudos Prospectivos , Artéria Renal/inervação , Medição de Risco , Fatores de Risco , Simpatectomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 81(2): 335-9, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22807098

RESUMO

BACKGROUND: Catheter-based renal sympathetic denervation (CRD) is associated with significant blood pressure (BP) reductions in patients with severe therapy-resistant hypertension (office systolic BP ≥ 160 mm Hg or ≥ 150 mm Hg in diabetic patients). Effects of renal denervation on BP in patients with milder forms of therapy-resistant hypertension have not been examined. We sought to investigate the feasibility, safety, and effectiveness of CRD in patients with longstanding mild hypertension despite treatment with ≥ 3 antihypertensive drugs. METHODS: Consecutive patients with office systolic BPs of 140-160 mm Hg despite ≥ 3 antihypertensive medications treated with CRD were included in this prospective study. Procedural safety and adverse events during follow-up were assessed. Clinical evaluations were performed at baseline, 3, and 6 months to determine changes in office systolic BPs, 24-hr ambulatory BPs, and medication doses. RESULTS: Twenty patients (mean age 60.6 ± 10.8 years; 45% female) treated with an average of 5.4 ± 1.5 antihypertensive drugs were treated with CRD. The procedure was successful in all patients. There were no procedure- or device-related complications. BP at baseline was 148.4/83.0 ± 6.6/11.0 mm Hg and decreased by 5.7/0.6 ± 20.0/8.3 mm Hg (P = 0.2) and 13.1/5.0 ± 13.6/8.3 mm Hg (P < 0.01) at 3 and 6 months, respectively. Comparing baseline and 6-month follow-up, mean ambulatory 24 hr-BP was reduced by 11.3/4.1 ± 8.6/7.3 mm Hg (P < 0.01). Four patients were able to reduce antihypertensive medications prior to their 3-month visit. CONCLUSION: As in patients with severe treatment-resistant hypertension, CRD is a safe and effective treatment for patients with milder drug-resistant hypertension.


Assuntos
Pressão Sanguínea , Ablação por Cateter , Hipertensão/cirurgia , Rim/inervação , Simpatectomia/métodos , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Monitorização Ambulatorial da Pressão Arterial , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Quimioterapia Combinada , Estudos de Viabilidade , Feminino , Humanos , Hipertensão/diagnóstico , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Visita a Consultório Médico , Projetos Piloto , Estudos Prospectivos , Simpatectomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Acad Radiol ; 29 Suppl 3: S88-S97, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33840600

RESUMO

RATIONALE AND OBJECTIVES: To evaluate cone-beam computed-tomography (CBCT) images of the temporal bone for radiological delineation, metal artifacts, and accuracy for localization of six different electrode arrays after cochlear device implantation. MATERIALS AND METHODS: This retrospective study included 116 patients who underwent CBCT (120kV, 7.1mA) within 24 hours after cochlear device implantation. Exclusion criteria were anatomical abnormalities, and electrode misinsertion. Six different CI electrodes were implanted: Advanced Bionics HiFocus Mid-Scala, Cochlear Contour Advance, Cochlear Slim-Straight, Cochlear Slim-Modiolar, MED-EL Flex 24 and MED-EL Flex 28. Two radiologists rated independently presence of metal artifacts, overall image quality, as well as dedicated visualization of the osseous spiral lamina, inner and outer cochlear wall, single electrode contacts, and electrode position using 5-point-Likert scales. Inter-rater agreement was calculated by using Cohen's kappa and intraclass correlation. RESULTS: Of 116 patients, 94 (81.0%; 56.1 ± 16.9 years; age range, 13-86 years; 49 [52.1%] females) were included in the study. Overall image quality was rated good for all electrode models without significant differences (p = 0.061). Depiction of electrode contacts was rated significantly better for Advanced Bionics HiFocus Mid-Scala, Cochlear Slim-Straight, and MED-EL Flex 24 and 28 compared to Cochlear Contour Advance and Slim-Modiolar (p < 0.001). Depiction of the osseous spiral lamina (p = 0.20), inner (p = 0.42) and outer cochlear wall (p = 0.35), metal artifacts (p = 0.18), and electrode position (p = 0.31) did not show significant differences between electrode models. Inter-rater agreement varied from substantial to almost perfect (0.70-0.93). CONCLUSION: CBCT provides excellent visualization of all evaluated CI electrode types, in particular electrode arrays with greater spacing between contacts and contact size allow improved radiologic evaluation.


Assuntos
Implante Coclear , Implantes Cocleares , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cóclea/cirurgia , Implante Coclear/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
17.
Eur J Sport Sci ; 22(9): 1436-1444, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34110980

RESUMO

Muscle injuries of the hamstrings are among the most frequent in football and a main cause for significant time away from training and competition. The purpose of this study was to prospectively evaluate the loss of muscle volume in recreational football players three and six weeks after initial trauma. We hypothesized that significant muscle volume loss occurs within 6 weeks after the initial injury event. Twenty recreational football players (mean-age=25 ± 4years; mean-height=181 ± 8cm; mean-weight=81 ± 10kg) with type3a (minor partial muscle tear) and type3b (moderate partial muscle tear) injuries were included. Muscle volume was determined using established methods for the hamstrings and the quadriceps femoris muscle within 3 days and after 3 and 6 weeks following the initial injury. The injured hamstrings lost 6.5% (mean=64 cm3(95%CI=31-98 cm3), p<0.001), the healthy hamstrings lost 2.1% (mean=21 cm3(3-44 cm3),p=0.096) of muscle volume after six weeks. The quadriceps in the injured leg lost 3.8% (mean=78 cm3(51-104 cm3), p<0.001) and 4.5% (83 cm3 (45-121 cm3), p<0.001) in the healthy leg. Muscle volume loss inversely correlated with activity levels in the healthy leg for the quadriceps (r=0.96 (0.90-0.98); R2=0.92; p<0.001) and the hamstrings (r=0.72 (0.40-0.88); R2=0.51; p<0.001), as well as the quadriceps in the injured leg (r=0.70 (0.37-0.87); R2=0.49; p<0.001), but not the injured hamstrings. Muscle volume ratio of hamstrings to quadriceps in the control limb was 0.52 ± 0.06 and 0.53 ± 0.06 in the injured leg. The rehabilitation period of six weeks did not have a relevant negative or a positive effect on ratios. Significant muscle volume loss in the upper thigh occurs in recreational soccer players within three, and within six weeks after a hamstring injury and lies between 2% and 7%.


Assuntos
Traumatismos em Atletas , Músculos Isquiossurais , Traumatismos da Perna , Futebol , Adulto , Humanos , Adulto Jovem , Traumatismos em Atletas/diagnóstico por imagem , Músculos Isquiossurais/fisiologia , Traumatismos da Perna/diagnóstico por imagem , Imageamento por Ressonância Magnética , Músculo Esquelético/fisiologia , Futebol/fisiologia
18.
Sci Rep ; 11(1): 14248, 2021 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-34244594

RESUMO

Our purpose was to analyze the robustness and reproducibility of magnetic resonance imaging (MRI) radiomic features. We constructed a multi-object fruit phantom to perform MRI acquisition as scan-rescan using a 3 Tesla MRI scanner. We applied T2-weighted (T2w) half-Fourier acquisition single-shot turbo spin-echo (HASTE), T2w turbo spin-echo (TSE), T2w fluid-attenuated inversion recovery (FLAIR), T2 map and T1-weighted (T1w) TSE. Images were resampled to isotropic voxels. Fruits were segmented. The workflow was repeated by a second reader and the first reader after a pause of one month. We applied PyRadiomics to extract 107 radiomic features per fruit and sequence from seven feature classes. We calculated concordance correlation coefficients (CCC) and dynamic range (DR) to obtain measurements of feature robustness. Intraclass correlation coefficient (ICC) was calculated to assess intra- and inter-observer reproducibility. We calculated Gini scores to test the pairwise discriminative power specific for the features and MRI sequences. We depict Bland Altmann plots of features with top discriminative power (Mann-Whitney U test). Shape features were the most robust feature class. T2 map was the most robust imaging technique (robust features (rf), n = 84). HASTE sequence led to the least amount of rf (n = 20). Intra-observer ICC was excellent (≥ 0.75) for nearly all features (max-min; 99.1-97.2%). Deterioration of ICC values was seen in the inter-observer analyses (max-min; 88.7-81.1%). Complete robustness across all sequences was found for 8 features. Shape features and T2 map yielded the highest pairwise discriminative performance. Radiomics validity depends on the MRI sequence and feature class. T2 map seems to be the most promising imaging technique with the highest feature robustness, high intra-/inter-observer reproducibility and most promising discriminative power.

19.
Breast Care (Basel) ; 15(6): 628-634, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33447237

RESUMO

PURPOSE: The aim of this study was to evaluate the feasibility and the accuracy of a secondary, metachronous ultrasound (US)-guided marking of the stereotactic vacuum-assisted breast biopsy (ST-VABB) area. MATERIALS AND METHODS: The institutional ethics committee approved the study. The retrospective study included 98 patients. In ST-VABB of 45 women, no tissue markers were deployed at the biopsy site, even if no residual calcifications remained. After histology proved the necessity for a subsequent operation, the biopsy site was marked under US guidance using a coil marker. All interventions were technically successful. No complications occurred. Mammography was done to visualize the coil deployment. The distances from the center of the lesion and the biopsy cavity to the coil location were measured in both planes to evaluate the accuracy of the marking procedure. RESULTS: In 24 of the 46 cases, the whole lesion was biopsied without residual elements. The mean time between ST-VABB and sonographic marking of the lesion was 9.7 days (median 6.5). The biopsy cavity could be detected in 40 (87%) cases and thus marked exactly. The mean time of US-guided marking was 12.5 min. The mean distance between the coil and the target lesion was 0.6 ± 1.5 cm in the craniocaudal (cc) view and 0.5 ± 1.5 cm in the mediolateral (ml) view for all markings. The mean delta value from the distance nipple-original lesion and from the distance nipple-coil was 0.85 ± 1.2 cm (median 0.5) in the cc view and 0.88 ± 1.2 cm (median 0.6) in the ml view for all cases. Clip migration was not observed. CONCLUSION: Our study demonstrates the feasibility and the technical success of secondary metachronous coil marking of the biopsy site under US guidance after receipt of histology. This approach seems to be a cost-effective alternative to the standard procedure of the primary coil marking especially in all completely removed lesions. It may offer advantages for allergic patients.

20.
Med Eng Phys ; 66: 56-64, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30826254

RESUMO

The purpose of the study was to validate the simulation model for a microwave thermal ablation in ex vivo liver tissue. The study aims to show that heat transfer due to the flow of tissue water during ablation in ex vivo tissue is not negligible. Ablation experiments were performed in ex vivo porcine liver with microwave powers of 60 W to 100 W. During the procedure, the temperature was recorded in the liver sample at different distances to the applicator using a fiber-optic thermometer. The position of the probes was identified by CT imaging and transferred to the simulation. The simulation of the heat distribution in the liver tissue was carried out with the software CST Studio Suite. The results of the simulation with different flow coefficients were compared with the results of the ablation experiments using the Bland-Altman analysis. The analysis showed that the flow coefficient of 90,000 W/(K*m3) can be considered as the most suitable value for clinically used powers. The presented simulation model can be used to calculate the temperature distribution for microwave ablation in ex vivo liver tissue.


Assuntos
Técnicas de Ablação , Temperatura Alta , Fígado , Micro-Ondas , Animais , Modelos Teóricos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA