J Nucl Med ; 46(5): 840-9, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15872359

RESUMO

UNLABELLED: (131)I radionuclide therapy studies have not shown a strong relationship between tumor absorbed dose and response, possibly due to inaccuracies in activity quantification and dose estimation. The goal of this work was to establish the accuracy of (131)I activity quantification and absorbed dose estimation when patient-specific, 3-dimensional (3D) methods are used for SPECT reconstruction and for absorbed dose calculation. METHODS: Clinically realistic voxel-phantom simulations were used in the evaluation of activity quantification and dosimetry. SPECT reconstruction was performed using an ordered-subsets expectation maximization (OSEM) algorithm with compensation for scatter, attenuation, and 3D detector response. Based on the SPECT image and a patient-specific density map derived from CT, 3D dosimetry was performed using a newly implemented Monte Carlo code. Dosimetry was evaluated by comparing mean absorbed dose estimates calculated directly from the defined phantom activity map with those calculated from the SPECT image of the phantom. Finally, the 3D methods were applied to a radioimmunotherapy patient, and the mean tumor absorbed dose from the new calculation was compared with that from conventional dosimetry obtained from conjugate-view imaging. RESULTS: Overall, the accuracy of the SPECT-based absorbed dose estimates in the phantom was >12% for targets down to 16 mL and up to 35% for the smallest 7-mL tumor. To improve accuracy in the smallest tumor, more OSEM iterations may be needed. The relative SD from multiple realizations was <3% for all targets except for the smallest tumor. For the patient, the mean tumor absorbed dose estimate from the new Monte Carlo calculation was 7% higher than that from conventional dosimetry. CONCLUSION: For target sizes down to 16 mL, highly accurate and precise dosimetry can be obtained with 3D methods for SPECT reconstruction and absorbed dose estimation. In the future, these methods can be applied to patients to potentially establish correlations between tumor regression and the absorbed dose statistics from 3D dosimetry.


Assuntos
Neoplasias Abdominais/radioterapia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Radioisótopos do Iodo/análise , Radioisótopos do Iodo/uso terapêutico , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Neoplasias Abdominais/diagnóstico por imagem , Algoritmos , Carga Corporal (Radioterapia) , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia Assistida por Computador/métodos , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA